Mechanistic investigation of ionization suppression in electrospray ionization
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We show results from experiments designed to determine the relative importance of gas phase processes and solution phase processes into ionization suppression observed in biological sample extracts. The data indicate that gas phase reactions leading to the loss of net charge on the analyte is not likely to be the most important process involved in ionization suppression. The results point to changes in the droplet solution properties caused by the presence of nonvolatile solutes as the main cause of ionization suppression in electrospray ionization of biological extracts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Self-citationMatuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Buhrman, D. L., Price, P. I., & Rudewiczcor, P. J. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00072-4 · Cited by 364
Cited by
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
Peters, F. T., Drummer, O. H., & Musshoff, F. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2006.05.021 · Cited by 1,343
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Metabolomics: Current analytical platforms and methodologies
(2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.11.021 · Cited by 1,192
Measuring the metabolome: current analytical technologies
Dunn, W. B., Bailey, N. J. C., & Johnson, H. E. (2005) · The Analyst · doi:10.1039/b418288j · Cited by 924
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
Chambers, E., Wagrowski-Diehl, D. M., Lu, Z., & Mazzeo, J. R. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.12.030 · Cited by 776
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS
Halket, J. M., Waterman, D., Przyborowska, A. M., Patel, R. K. P., Fraser, P. D., & Bramley, P. M. (2005) · Journal of Experimental Botany · doi:10.1093/jxb/eri069 · Cited by 662
Dams, R., Huestis, M. A., Lambert, W. E., & Murphy, C. M. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00574-9 · Cited by 600
Carr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Hebert, A. S., Richards, A. L., Bailey, D. J., Ulbrich, A., Coughlin, E. E., Westphall, M. S., & Coon, J. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.034769 · Cited by 528
Ion suppression; A critical review on causes, evaluation, prevention and applications
Furey, A., Moriarty, M., Bane, V., Kinsella, B., & Lehane, M. (2013) · Talanta · doi:10.1016/j.talanta.2013.03.048 · Cited by 521
Ferrer, C., Lozano, A., Agüera, A., Girón, A. J., & Fernández-Alba, A. R. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.033 · Cited by 485
Mallet, C. R., Lu, Z., & Mazzeo, J. R. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1276 · Cited by 441
Matrix effects in quantitative pesticide analysis using liquid chromatography–mass spectrometry
Niessen, W. M. A., Manini, P., & Andreoli, R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20097 · Cited by 435
Matrix Effects and Application of Matrix Effect Factor
Zhou, W., Yang, S., & Wang, P. G. (2017) · Bioanalysis · doi:10.4155/bio-2017-0214 · Cited by 430
Chelius, D., & Bondarenko, P. V. (2002) · Journal of Proteome Research · doi:10.1021/pr025517j · Cited by 423
Lee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Metabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Panuwet, P., Hunter, R. E., D'Souza, P. E., Chen, X., Radford, S. A., Cohen, J. R., Marder, M. E., Kartavenka, K., Ryan, P. B., & Barr, D. B. (2016) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.980775 · Cited by 394
Bondarenko, P. V., Chelius, D., & Shaler, T. A. (2002) · Analytical Chemistry · doi:10.1021/ac0256991 · Cited by 387
Recent advances in sample preparation techniques for effective bioanalytical methods
Kole, P. L., Venkatesh, G., Kotecha, J., & Sheshala, R. (2011) · Biomedical Chromatography · doi:10.1002/bmc.1560 · Cited by 366
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Matrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometry
Kruve, A., Künnapas, A., Herodes, K., & Leito, I. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.077 · Cited by 322
Learning representations of microbe–metabolite interactions
Morton, J. T., Aksenov, A. A., Nothias, L. F., Foulds, J. R., Quinn, R. A., Badri, M. H., Swenson, T. L., Van Goethem, M. W., Northen, T. R., Vazquez-Baeza, Y., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0616-3 · Cited by 299
Simón-Manso, Y., Lowenthal, M. S., Kilpatrick, L. E., Sampson, M. L., Telu, K. H., Rudnick, P. A., Mallard, W. G., Bearden, D. W., Schock, T. B., Tchekhovskoi, D. V., et al. (2013) · Analytical Chemistry · doi:10.1021/ac402503m · Cited by 294
Allwood, J. W., & Goodacre, R. (2010) · Phytochemical Analysis · doi:10.1002/pca.1187 · Cited by 282
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
A review of the pharmaceutical exposome in aquatic fauna
Miller, T. H., Bury, N. R., Owen, S. F., MacRae, J. I., & Barron, L. P. (2018) · Environmental Pollution · doi:10.1016/j.envpol.2018.04.012 · Cited by 262
Xu, X., Roman, J. M., Issaq, H. J., Keefer, L. K., Veenstra, T. D., & Ziegler, R. G. (2007) · Analytical Chemistry · doi:10.1021/ac070494j · Cited by 260
Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology
Maurer, H. H. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1248-5 · Cited by 257
Müller, C., Schäfer, P., Störtzel, M., Vogt, S., & Weinmann, W. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00142-3 · Cited by 253
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Liang, H. R., Foltz, R. L., Meng, M., & Bennett, P. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1268 · Cited by 247
Kwon, H., Lehotay, S. J., & Geis-Asteggiante, L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.10.059 · Cited by 246
Intestinal microbiota-derived tryptophan metabolites are predictive of Ah receptor activity
Dong, F., Hao, F., Murray, I. A., Smith, P. B., Koo, I., Tindall, A. M., Kris-Etherton, P. M., Gowda, K., Amin, S. G., Patterson, A. D., et al. (2020) · Gut Microbes · doi:10.1080/19490976.2020.1788899 · Cited by 245
“The matrix effect is caused by the components coextracted with the analytes which could suppress or enhance the signal response of target analytes.(39,40) Matrix effect could lead to poor analytical accuracy of quantification of an analyte.”
BackgroundCho, Y., Ahmed, A., Islam, A., & Kim, S. (2015) · Mass Spectrometry Reviews · doi:10.1002/mas.21438 · Cited by 245
Fractionation of Isotopically Labeled Peptides in Quantitative Proteomics
Zhang, R., Sioma, C. S., Wang, S., & Regnier, F. E. (2001) · Analytical Chemistry · doi:10.1021/ac010583a · Cited by 233
Stable-Isotope Dilution LC–MS for Quantitative Biomarker Analysis
Ciccimaro, E., & Blair, I. A. (2010) · Bioanalysis · doi:10.4155/bio.09.185 · Cited by 226
Liquid chromatography-electrospray ionization-mass spectrometry: the future of DNA adduct detection
Singh, R., & Farmer, P. B. (2006) · Carcinogenesis · doi:10.1093/carcin/bgi260 · Cited by 221
Benijts, T., Dams, R., Lambert, W., & De Leenheer, A. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.12.022 · Cited by 216
Molecular imaging and depth profiling by mass spectrometry—SIMS, MALDI or DESI?
Vickerman, J. C. (2011) · The Analyst · doi:10.1039/c1an00008j · Cited by 211
Balakrishnan, V. K., Terry, K. A., & Toito, J. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.07.011 · Cited by 206
Liquid chromatography-mass spectrometry for the determination of chemical contaminants in food
Hird, S. J., Lau, B. P.-Y., Schuhmacher, R., & Krska, R. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.04.005 · Cited by 203
“The predominant cause is the presence of undesired components that co-elute in the chromatographic separation and compete for access to the surface of droplets and subsequent “ion evaporation” or changes in eluent properties, such as surface tension, viscosity, volatility – all factors known to affect the ionization p…”
BackgroundHuang, L. C., Zheng, N., Zheng, B. Q., Wen, F., Cheng, J. B., Han, R. W., Xu, X. M., Li, S. L., & Wang, J. Q. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2013.09.047 · Cited by 202
Abbatiello, S. E., Mani, D. R., Keshishian, H., & Carr, S. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138420 · Cited by 198
Rovelli, G., Jacobs, M. I., Willis, M. D., Rapf, R. J., Prophet, A. M., & Wilson, K. R. (2020) · Chemical Science · doi:10.1039/d0sc04611f · Cited by 198
Kloepfer, A., Quintana, J. B., & Reemtsma, T. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.11.101 · Cited by 198
Steiner, D., Krska, R., Malachová, A., Taschl, I., & Sulyok, M. (2020) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.9b07706 · Cited by 194
Niessen, W. M. A. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00506-5 · Cited by 193
Perrone, D., Donangelo, C. M., & Farah, A. (2008) · Food Chemistry · doi:10.1016/j.foodchem.2008.03.012 · Cited by 190
Comparative assessment of bioanalytical method validation guidelines for pharmaceutical industry
Kadian, N., Raju, K. S. R., Rashid, M., Malik, M. Y., Taneja, I., & Wahajuddin, M. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.03.052 · Cited by 185
Reduction of Signal Suppression Effects in ESI-MS Using a Nanosplitting Device
Gangl, E. T., Annan, M., Spooner, N., & Vouros, P. (2001) · Analytical Chemistry · doi:10.1021/ac010501i · Cited by 182
Hewavitharana, A. K. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.11.047 · Cited by 179
Maurer, H. H. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.250 · Cited by 178
Plant metabolomics: potential for practical operation
Fukusaki, E., & Kobayashi, A. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.347 · Cited by 178
Mass Spectrometry, Review of the Basics: Ionization
Awad, H., Khamis, M. M., & El-Aneed, A. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.954046 · Cited by 176
“These differences between ESI and APCI are mainly based on ionization mechanism differences (35).”
BackgroundInfluentialMatrix Effects—A Challenge toward Automation of Molecular Analysis
Chiu, M. L., Lawi, W., Snyder, S. T., Wong, P. K., Liao, J. C., & Gau, V. (2010) · JALA: Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2010.02.001 · Cited by 175
Processing and classification of protein mass spectra
Hilario, M., Kalousis, A., Pellegrini, C., & Müller, M. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20072 · Cited by 172
“In ESI spectra, chemical noise can form a bump in the baseline in the intermediate mass range.”
BackgroundInfluentialArike, L., Valgepea, K., Peil, L., Nahku, R., Adamberg, K., & Vilu, R. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.06.020 · Cited by 170
“[10] King R, Bonfiglio R, Fernandez-Metzler C, Miller-Stein C, Olah T.”
BackgroundWaterval, W. A. H., Scheijen, J. L. J. M., Ortmans-Ploemen, M. M. J. C., Habets-van der Poel, C. D., & Bierau, J. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.06.023 · Cited by 164
Liquid chromatography–tandem mass spectrometry applications in endocrinology
Kushnir, M. M., Rockwood, A. L., & Bergquist, J. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20264 · Cited by 159
“Several methods could be used to determine whether sample matrix affects performance of a method (Bonfiglio et al., 1999; King et al., 2000; Matuszewski, Constanzer, & Chavez-Eng, 2003; Kaufmann and Butcher, 2005).”
MethodPeters, F. T., & Remane, D. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6035-2 · Cited by 159
“found elsewhere [10, 12–18].”
BackgroundDraper, J., Lloyd, A. J., Goodacre, R., & Beckmann, M. (2013) · Metabolomics · doi:10.1007/s11306-012-0449-x · Cited by 144
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Keski‐Rahkonen, P., Huhtinen, K., Desai, R., Tim Harwood, D., Handelsman, D. J., Poutanen, M., & Auriola, S. (2013) · Journal of Mass Spectrometry · doi:10.1002/jms.3252 · Cited by 47
“2, analysis of the biological samples revealed the well-known susceptibility of ESI to ion suppression.([46,47]) This was particularly strong for the serum samples and negative polarity, despite the relatively clean sample extracts and a long gradient elution.”
BackgroundDeveloping a Cell Quenching Method to Facilitate Single Cell Mass Spectrometry Metabolomics Studies
Wije Munige, S., Bhusal, D., Peng, Z., Chen, D., & Yang, Z. (2025) · JACS Au · doi:10.1021/jacsau.5c00327 · Cited by 11
Metadata
- Authors
- King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-11-01
- Volume
- 11
- Issue
- 11
- Pages
- 942-950
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2041575674
- Cited by
- 1,086
- References
- 14
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.