The DOI matches its OpenAlex record; 25 of the 25 references it cites were found in a registry or an index.
Removing electroencephalographic artifacts by blind source separation
Abstract
Eye movements, eye blinks, cardiac signals, muscle noise, and line noise present serious problems for electroencephalographic (EEG) interpretation and analysis when rejecting contaminated EEG segments results in an unacceptable data loss. Many methods have been proposed to remove artifacts from EEG recordings, especially those arising from eye movements and blinks. Often regression in the time or frequency domain is performed on parallel EEG and electrooculographic (EOG) recordings to derive parameters characterizing the appearance and spread of EOG artifacts in the EEG channels. Because EEG and ocular activity mix bidirectionally, regressing out eye artifacts inevitably involves subtracting relevant EEG signals from each record as well. Regression methods become even more problematic when a good regressing channel is not available for each artifact source, as in the case of muscle artifacts. Use of principal component analysis (PCA) has been proposed to remove eye artifacts from multichannel EEG. However, PCA cannot completely separate eye artifacts from brain signals, especially when they have comparable amplitudes. Here, we propose a new and generally applicable method for removing a wide variety of artifacts from EEG records based on blind source separation by independent component analysis (ICA). Our results on EEG data collected from normal and autistic subjects show that ICA can effectively detect, separate, and remove contamination from a wide variety of artifactual sources in EEG records with results comparing favorably with those obtained using regression and PCA methods. ICA can also be used to analyze blink-related brain activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Self-citationA New Learning Algorithm for Blind Signal Separation
Амари, Ш.-И., Cichocki, A. S., & Yang, H. H. (1995) · Cited by 1,904
Calculating the Singular Values and Pseudo-Inverse of a Matrix
Golub, G., & Kahan, W. (1965) · Journal of the Society for Industrial and Applied Mathematics Series B Numerical Analysis · doi:10.1137/0702016 · Cited by 1,786
The removal of the eye-movement artifact from the EEG by regression analysis in the frequency domain
Woestenburg, J. C., Verbaten, M. N., & Slangen, J. L. (1983) · Biological Psychology · doi:10.1016/0301-0511(83)90059-5 · Cited by 352
Lagerlund, T. D., Sharbrough, F. W., & Busacker, N. E. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199701000-00007 · Cited by 319
Nonlinear neurons in the low-noise limit: a factorial code maximizes information transfer
Nadal, J., & Parga, N. (1994) · Network Computation in Neural Systems · doi:10.1088/0954-898x/5/4/008 · Cited by 282
Cited by
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Self-citationBrain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
ERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
Independent Component Analysis: Principles and Practice
(2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511624148 · Cited by 1,917
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
Self-citationNon-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Mining event-related brain dynamics
Makeig, S., Debener, S., Onton, J., & Delorme, A. (2004) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2004.03.008 · Cited by 1,493
Self-citationJung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Self-citationADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Xu, Y., & Yin, W. (2013) · SIAM Journal on Imaging Sciences · doi:10.1137/120887795 · Cited by 1,160
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
(2004) · Dictionary of Strategy: Strategic Management A-Z · doi:10.4135/9781452229805.n17 · Cited by 938
EEG frequency bands in psychiatric disorders: a review of resting state studies
Newson, J. J., & Thiagarajan, T. C. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00521 · Cited by 863
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Transient induced gamma-band response in EEG as a manifestation of miniature saccades
Yuval-Greenberg, S., Tomer, O., Keren, A. S., Nelken, I., & Deouell, L. Y. (2008) · Neuron · doi:10.1016/j.neuron.2008.03.027 · Cited by 776
Independent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Self-citationEnhancing Detection of SSVEPs for a High-Speed Brain Speller Using Task-Related Component Analysis
Nakanishi, M., Wang, Y., Chen, X., Wang, Y.-T., Gao, X., & Jung, T.-P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694818 · Cited by 813
Self-citationAutomatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Blind Source Separation by Sparse Decomposition in a Signal Dictionary
Zibulevsky, M., & Pearlmutter, B. A. (2001) · Neural Computation · doi:10.1162/089976601300014385 · Cited by 766
Mental Training Affects Distribution of Limited Brain Resources
Slagter, H. A., Lutz, A., Greischar, L. L., Francis, A. D., Nieuwenhuis, S., Davis, J. M., & Davidson, R. J. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050138 · Cited by 757
A MATLAB toolbox for Granger causal connectivity analysis
Seth, A. K. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.11.020 · Cited by 750
The neural correlates of dreaming
Siclari, F., Baird, B., Perogamvros, L., Bernardi, G., LaRocque, J. J., Riedner, B., Boly, M., Postle, B. R., & Tononi, G. (2017) · Nature Neuroscience · doi:10.1038/nn.4545 · Cited by 758
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741
Good practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
Comparison of linear, nonlinear, and feature selection methods for EEG signal classification
Garrett, D., Peterson, D. A., Anderson, C. W., & Thaut, M. H. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814441 · Cited by 735
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
Imaging human EEG dynamics using independent component analysis
Onton, J., Westerfield, M., Townsend, J., & Makeig, S. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.007 · Cited by 673
Self-citationAnalysis and visualization of single‐trial event‐related potentials
Jung, T., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1050 · Cited by 655
Self-citationOscillatory synchronization in large-scale cortical networks predicts perception
Hipp, J. F., Engel, A. K., & Siegel, M. (2011) · Neuron · doi:10.1016/j.neuron.2010.12.027 · Cited by 599
Inter- and intra-individual variability in alpha peak frequency
Haegens, S., Cousijn, H., Wallis, G., Harrison, P. J., & Nobre, A. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.049 · Cited by 598
Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
Joyce, C. A., Gorodnitsky, I. F., & Kutas, M. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2003.00141.x · Cited by 596
Imaging brain dynamics using independent component analysis
Jung, T.-P., Makeig, S., McKeown, M. J., Bell, A. J., Lee, T.-W., & Sejnowski, T. J. (2001) · Proceedings of the IEEE · doi:10.1109/5.939827 · Cited by 592
Self-citationCastellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
Sassenhagen, J., & Draschkow, D. (2019) · Psychophysiology · doi:10.1111/psyp.13335 · Cited by 545
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Self-citationBrain-computer interfaces for communication and control
McFarland, D. J., & Wolpaw, J. R. (2011) · Communications of the ACM · doi:10.1145/1941487.1941506 · Cited by 519
An accumulator model for spontaneous neural activity prior to self-initiated movement
Schurger, A., Sitt, J. D., & Dehaene, S. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210467109 · Cited by 505
Diagnosis of Alzheimers Disease from EEG Signals: Where Are We Standing?
Dauwels, J., Vialatte, F., & Cichocki, A. (2010) · Current Alzheimer Research · doi:10.2174/156720510792231720 · Cited by 492
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481
Self-citationElectrocortical activity is coupled to gait cycle phase during treadmill walking
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.066 · Cited by 479
Self-citationEEG-based drowsiness estimation for safety driving using independent component analysis
Lin, C.-T., Wu, R.-C., Liang, S.-F., Chao, W.-H., Chen, Y.-J., & Jung, T.-P. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.857555 · Cited by 470
Self-citationHaegens, S., Händel, B. F., & Jensen, O. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.5199-10.2011 · Cited by 469
Statistical physics of inference: thresholds and algorithms
Zdeborová, L., & Krzakala, F. (2016) · Advances in Physics · doi:10.1080/00018732.2016.1211393 · Cited by 440
Classification of human emotion from EEG using discrete wavelet transform
Murugappan, M., Ramachandran, N., & Sazali, Y. (2010) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2010.34054 · Cited by 436
Transfer Learning for EEG-Based Brain–Computer Interfaces: A Review of Progress Made Since 2016
Wu, D., Xu, Y., & Lu, B.-L. (2022) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.3007453 · Cited by 434
A multimodal approach to estimating vigilance using EEG and forehead EOG
Zheng, W.-L., & Lu, B.-L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a98 · Cited by 424
Zaehle, T., Sandmann, P., Thorne, J. D., Jäncke, L., & Herrmann, C. S. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-2 · Cited by 407
Consciousness and Complexity during Unresponsiveness Induced by Propofol, Xenon, and Ketamine
Sarasso, S., Boly, M., Napolitani, M., Gosseries, O., Charland-Verville, V., Casarotto, S., Rosanova, M., Casali, A. G., Brichant, J.-F., Boveroux, P., et al. (2015) · Current Biology · doi:10.1016/j.cub.2015.10.014 · Cited by 399
Linking brain, mind and behavior
Makeig, S., Gramann, K., Jung, T.-P., Sejnowski, T. J., & Poizner, H. (2009) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2008.11.008 · Cited by 390
Self-citationEEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
Mijović, B., De Vos, M., Gligorijević, I., Taelman, J., & Van Huffel, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051440 · Cited by 382
Nociceptive Laser-Evoked Brain Potentials Do Not Reflect Nociceptive-Specific Neural Activity
Mouraux, A., & Iannetti, G. D. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91181.2008 · Cited by 373
Plöchl, M., Ossandón, J. P., & König, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00278 · Cited by 372
Clinical application of the P300 event-related brain potential
Polich, J. (2004) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/s1047-9651(03)00109-8 · Cited by 366
Semi-automatic identification of independent components representing EEG artifact
Campos Viola, F., Thorne, J., Edmonds, B., Schneider, T., Eichele, T., & Debener, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.015 · Cited by 364
Artifact Removal in Physiological Signals—Practices and Possibilities
Sweeney, K. T., Ward, T. E., & McLoone, S. F. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188536 · Cited by 361
Regional brain wave activity changes associated with fatigue
Craig, A., Tran, Y., Wijesuriya, N., & Nguyen, H. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01329.x · Cited by 359
The motor cortex drives the muscles during walking in human subjects
Petersen, T. H., Willerslev‐Olsen, M., Conway, B. A., & Nielsen, J. B. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.227397 · Cited by 358
Electroencephalographic Brain Dynamics Following Manually Responded Visual Targets
Makeig, S., Delorme, A., Westerfield, M., Jung, T.-P., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020176 · Cited by 357
Self-citationPerception of effort reflects central motor command during movement execution
de Morree, H. M., Klein, C., & Marcora, S. M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01399.x · Cited by 350
EEG-based workers' stress recognition at construction sites
Jebelli, H., Hwang, S., & Lee, S. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.05.027 · Cited by 339
Smith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
Evaluation of Artifact Subspace Reconstruction for Automatic EEG Artifact Removal
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512547 · Cited by 335
Self-citationPersistent EEG overactivation in the cortical pain matrix of neurogenic pain patients
Stern, J., Jeanmonod, D., & Sarnthein, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.042 · Cited by 334
Reinforcement Learning Signals Predict Future Decisions
Cohen, M. X., & Ranganath, C. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.4421-06.2007 · Cited by 333
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Wallstrom, G. L., Kass, R. E., Miller, A., Cohn, J. F., & Fox, N. A. (2004) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2004.03.007 · Cited by 326
Patient-specific seizure onset detection
Shoeb, A., Edwards, H., Connolly, J., Bourgeois, B., Ted Treves, S., & Guttag, J. (2004) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2004.05.005 · Cited by 312
Parasuraman, R., & Rizzo, M. (2006) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195177619.001.0001 · Cited by 311
Lithari, C., Frantzidis, C. A., Papadelis, C., Vivas, A. B., Klados, M. A., Kourtidou-Papadeli, C., Pappas, C., Ioannides, A. A., & Bamidis, P. D. (2010) · Brain Topography · doi:10.1007/s10548-009-0130-5 · Cited by 311
Clinical Utility of EEG in Attention-Deficit/Hyperactivity Disorder: A Research Update
Loo, S. K., & Makeig, S. (2012) · Neurotherapeutics · doi:10.1007/s13311-012-0131-z · Cited by 306
Self-citationNeuroergonomics: a review of applications to physical and cognitive work
Mehta, R. K., & Parasuraman, R. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00889 · Cited by 306
Advances in Quantitative Electroencephalogram Analysis Methods
Thakor, N. V., & Tong, S. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121601 · Cited by 305
Occipital gamma activation during Vipassana meditation
Cahn, B. R., Delorme, A., & Polich, J. (2010) · Cognitive Processing · doi:10.1007/s10339-009-0352-1 · Cited by 300
Large-scale replication study reveals a limit on probabilistic prediction in language comprehension
Nieuwland, M. S., Politzer-Ahles, S., Heyselaar, E., Segaert, K., Darley, E., Kazanina, N., Von Grebmer Zu Wolfsthurn, S., Bartolozzi, F., Kogan, V., Ito, A., et al. (2018) · eLife · doi:10.7554/elife.33468 · Cited by 299
Automagic: Standardized preprocessing of big EEG data
Pedroni, A., Bahreini, A., & Langer, N. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.046 · Cited by 292
Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study
Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., & Artieda, J. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200307000-00004 · Cited by 289
Debener, S., Makeig, S., Delorme, A., & Engel, A. K. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2004.09.006 · Cited by 287
Self-citationBOLD correlates of EEG alpha phase-locking and the fMRI default mode network
Jann, K., Dierks, T., Boesch, C., Kottlow, M., Strik, W., & Koenig, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.001 · Cited by 286
Papadelis, C., Chen, Z., Kourtidou-Papadeli, C., Bamidis, P. D., Chouvarda, I., Bekiaris, E., & Maglaveras, N. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.031 · Cited by 268
Kappenman, E. S., Farrens, J. L., Luck, S. J., & Proudfit, G. H. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01368 · Cited by 266
Mars, R. B., Debener, S., Gladwin, T. E., Harrison, L. M., Haggard, P., Rothwell, J. C., & Bestmann, S. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2925-08.2008 · Cited by 264
Srivastava, G., Crottaz-Herbette, S., Lau, K. M., Glover, G. H., & Menon, V. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.041 · Cited by 264
Saccadic spike potentials in gamma-band EEG: Characterization, detection and suppression
Keren, A. S., Yuval-Greenberg, S., & Deouell, L. Y. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.057 · Cited by 263
Atrial Activity Extraction for Atrial Fibrillation Analysis Using Blind Source Separation
Rieta, J. J., Castells, F., Sanchez, C., Zarzoso, V., & Millet, J. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827272 · Cited by 263
Signal processing techniques applied to human sleep EEG signals—A review
Motamedi-Fakhr, S., Moshrefi-Torbati, M., Hill, M., Hill, C. M., & White, P. R. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.12.003 · Cited by 263
The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent Methods
Hoffmann, S., & Falkenstein, M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003004 · Cited by 261
Multivariate Statistical Analyses for Neuroimaging Data
McIntosh, A. R., & Mišić, B. (2013) · Annual Review of Psychology · doi:10.1146/annurev-psych-113011-143804 · Cited by 260
Visual activation of auditory cortex reflects maladaptive plasticity in cochlear implant users
Sandmann, P., Dillier, N., Eichele, T., Meyer, M., Kegel, A., Pascual-Marqui, R. D., Marcar, V. L., Jäncke, L., & Debener, S. (2012) · Brain · doi:10.1093/brain/awr329 · Cited by 259
Xu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258
Konvalinka, I., Bauer, M., Stahlhut, C., Hansen, L. K., Roepstorff, A., & Frith, C. D. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.003 · Cited by 228
Siclari, F., Bernardi, G., Riedner, B. A., LaRocque, J. J., Benca, R. M., & Tononi, G. (2014) · Sleep · doi:10.5665/sleep.4070 · Cited by 181
Vecchio, F., Miraglia, F., Marra, C., Quaranta, D., Vita, M. G., Bramanti, P., & Rossini, P. M. (2014) · Journal of Alzheimer's Disease · doi:10.3233/jad-132087 · Cited by 182
Sleep deprivation leads to a loss of functional connectivity in frontal brain regions
Verweij, I. M., Romeijn, N., Smit, D. J., Piantoni, G., Van Someren, E. J., & van der Werf, Y. D. (2014) · BMC Neuroscience · doi:10.1186/1471-2202-15-88 · Cited by 180
Perry, A., Troje, N. F., & Bentin, S. (2010) · Social Neuroscience · doi:10.1080/17470910903395767 · Cited by 161
Tye, C., Asherson, P., Ashwood, K. L., Azadi, B., Bolton, P., & McLoughlin, G. (2014) · Psychological Medicine · doi:10.1017/s0033291713001049 · Cited by 158
Dreaming in NREM Sleep: A High-Density EEG Study of Slow Waves and Spindles
Siclari, F., Bernardi, G., Cataldi, J., & Tononi, G. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.0855-18.2018 · Cited by 143
Metadata
- Authors
- Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2000-03-01
- Volume
- 37
- Issue
- 2
- Pages
- 163-178
- ISSN
- 0048-5772 (ISSN-L)
- OpenAlex
- W2079277602
- Cited by
- 3,334
- References
- 25
- FWCI
- 12.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.