Removing electroencephalographic artifacts by blind source separation
The DOI matches its OpenAlex record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Eye movements, eye blinks, cardiac signals, muscle noise, and line noise present serious problems for electroencephalographic (EEG) interpretation and analysis when rejecting contaminated EEG segments results in an unacceptable data loss. Many methods have been proposed to remove artifacts from EEG recordings, especially those arising from eye movements and blinks. Often regression in the time or frequency domain is performed on parallel EEG and electrooculographic (EOG) recordings to derive parameters characterizing the appearance and spread of EOG artifacts in the EEG channels. Because EEG and ocular activity mix bidirectionally, regressing out eye artifacts inevitably involves subtracting relevant EEG signals from each record as well. Regression methods become even more problematic when a good regressing channel is not available for each artifact source, as in the case of muscle artifacts. Use of principal component analysis (PCA) has been proposed to remove eye artifacts from multichannel EEG. However, PCA cannot completely separate eye artifacts from brain signals, especially when they have comparable amplitudes. Here, we propose a new and generally applicable method for removing a wide variety of artifacts from EEG records based on blind source separation by independent component analysis (ICA). Our results on EEG data collected from normal and autistic subjects show that ICA can effectively detect, separate, and remove contamination from a wide variety of artifactual sources in EEG records with results comparing favorably with those obtained using regression and PCA methods. ICA can also be used to analyze blink-related brain activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Self-citationA New Learning Algorithm for Blind Signal Separation
Амари, Ш.-И., Cichocki, A. S., & Yang, H. H. (1995) · Cited by 1,904
Calculating the Singular Values and Pseudo-Inverse of a Matrix
Golub, G., & Kahan, W. (1965) · Journal of the Society for Industrial and Applied Mathematics Series B Numerical Analysis · doi:10.1137/0702016 · Cited by 1,786
The removal of the eye-movement artifact from the EEG by regression analysis in the frequency domain
Woestenburg, J. C., Verbaten, M. N., & Slangen, J. L. (1983) · Biological Psychology · doi:10.1016/0301-0511(83)90059-5 · Cited by 352
Lagerlund, T. D., Sharbrough, F. W., & Busacker, N. E. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199701000-00007 · Cited by 319
Nonlinear neurons in the low-noise limit: a factorial code maximizes information transfer
Nadal, J., & Parga, N. (1994) · Network Computation in Neural Systems · doi:10.1088/0954-898x/5/4/008 · Cited by 282
Cited by
Items 101–164 of 164
Neural Oscillations Associated with Item and Temporal Order Maintenance in Working Memory
Hsieh, L.-T., Ekstrom, A. D., & Ranganath, C. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.0828-11.2011 · Cited by 224
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
Concealed, Unobtrusive Ear-Centered EEG Acquisition: cEEGrids for Transparent EEG
Bleichner, M. G., & Debener, S. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00163 · Cited by 215
EEG classification of driver mental states by deep learning
Zeng, H., Yang, C., Dai, G., Qin, F., Zhang, J., & Kong, W. (2018) · Cognitive Neurodynamics · doi:10.1007/s11571-018-9496-y · Cited by 215
Rossion, B., Torfs, K., Jacques, C., & Liu-Shuang, J. (2015) · Journal of Vision · doi:10.1167/15.1.18 · Cited by 211
Siclari, F., Bernardi, G., Riedner, B. A., LaRocque, J. J., Benca, R. M., & Tononi, G. (2014) · Sleep · doi:10.5665/sleep.4070 · Cited by 181
Wang, D., Chen, J., Zhao, D., Dai, F., Zheng, C., & Wu, X. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.02.001 · Cited by 189
Brunner, C., Naeem, M., Leeb, R., Graimann, B., & Pfurtscheller, G. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2007.01.002 · Cited by 187
Beta- and gamma-range human lower limb corticomuscular coherence
Gwin, J. T., & Ferris, D. P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00258 · Cited by 183
Vecchio, F., Miraglia, F., Marra, C., Quaranta, D., Vita, M. G., Bramanti, P., & Rossini, P. M. (2014) · Journal of Alzheimer's Disease · doi:10.3233/jad-132087 · Cited by 182
“It has been proposed as an effective method for separating ocular movement and blink artifacts from EEG data [68–71].”
Sleep deprivation leads to a loss of functional connectivity in frontal brain regions
Verweij, I. M., Romeijn, N., Smit, D. J., Piantoni, G., Van Someren, E. J., & van der Werf, Y. D. (2014) · BMC Neuroscience · doi:10.1186/1471-2202-15-88 · Cited by 180
“Movement artifacts were removed and independent component analysis (ICA) was applied to remove eye artifacts [36].”
MethodPeters, J. M., Taquet, M., Vega, C., Jeste, S. S., Fernández, I. S., Tan, J., Nelson, C. A., Sahin, M., & Warfield, S. K. (2013) · BMC Medicine · doi:10.1186/1741-7015-11-54 · Cited by 180
Discourse-Based Word Anticipation During Language Processing: Prediction or Priming?
Otten, M., & Van Berkum, J. J. A. (2008) · Discourse Processes · doi:10.1080/01638530802356463 · Cited by 176
Marshall, P. J., Young, T., & Meltzoff, A. N. (2011) · Developmental Science · doi:10.1111/j.1467-7687.2010.00991.x · Cited by 165
Dimitrakopoulos, G. N., Kakkos, I., Dai, Z., Wang, H., Sgarbas, K., Thakor, N., Bezerianos, A., & Sun, Y. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2791936 · Cited by 163
Perry, A., Troje, N. F., & Bentin, S. (2010) · Social Neuroscience · doi:10.1080/17470910903395767 · Cited by 161
“Eye movements were corrected using an ICA procedure (Jung et al., 2000).”
Tye, C., Asherson, P., Ashwood, K. L., Azadi, B., Bolton, P., & McLoughlin, G. (2014) · Psychological Medicine · doi:10.1017/s0033291713001049 · Cited by 158
Dreaming in NREM Sleep: A High-Density EEG Study of Slow Waves and Spindles
Siclari, F., Bernardi, G., Cataldi, J., & Tononi, G. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.0855-18.2018 · Cited by 143
Murugappan, M., & Murugappan, S. (2013) · 2013 IEEE 9th International Colloquium on Signal Processing and its Applications · doi:10.1109/cspa.2013.6530058 · Cited by 152
“This is one of the reasons why considerable experience is required to interpret EEGs clinically [9, 10].”
BackgroundTownsend, J., Westerfield, M., Leaver, E., Makeig, S., Jung, T.-P., Pierce, K., & Courchesne, E. (2001) · Cognitive Brain Research · doi:10.1016/s0926-6410(00)00072-0 · Cited by 151
Self-citationCognitive and neurophysiological markers of ADHD persistence and remission
Cheung, C. H. M., Rijsdijk, F., McLoughlin, G., Brandeis, D., Banaschewski, T., Asherson, P., & Kuntsi, J. (2016) · British Journal of Psychiatry · doi:10.1192/bjp.bp.114.145185 · Cited by 146
The brain matures with stronger functional connectivity and decreased randomness of its network
Smit, D. J. A., Boersma, M., Schnack, H. G., Micheloyannis, S., Boomsma, D. I., Hulshoff Pol, H. E., Stam, C. J., & de Geus, E. J. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0036896 · Cited by 143
“Next, we used the extended ICA decomposition implemented in EEGLA [39] to remove artifacts, including eye movements, and blink [40].”
MethodGenetic contributions to long-range temporal correlations in ongoing oscillations
Linkenkaer-Hansen, K., Smit, D. J. A., Barkil, A., van Beijsterveldt, T. E. M., Brussaard, A. B., Boomsma, D. I., van Ooyen, A., & de Geus, E. J. C. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3083-07.2007 · Cited by 138
Theta Phase Synchrony and Conscious Target Perception: Impact of Intensive Mental Training
Slagter, H. A., Lutz, A., Greischar, L. L., Nieuwenhuis, S., & Davidson, R. J. (2009) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21125 · Cited by 132
Dysfunctional forward model mechanisms and aberrant sense of agency in obsessive-compulsive disorder
Gentsch, A., Schütz-Bosbach, S., Endrass, T., & Kathmann, N. (2012) · Biological Psychiatry · doi:10.1016/j.biopsych.2011.12.022 · Cited by 123
Don’t stand so close to me: a behavioral and ERP study of preferred interpersonal distance
Perry, A., Rubinsten, O., Peled, L., & Shamay-Tsoory, S. G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.042 · Cited by 118
Spatial Filtering for EEG-Based Regression Problems in Brain–Computer Interface (BCI)
Wu, D., King, J.-T., Chuang, C.-H., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2017.2688423 · Cited by 116
Self-citationMcLoughlin, G., Palmer, J. A., Rijsdijk, F., & Makeig, S. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.07.020 · Cited by 100
“t-related potentials (ERPs) in the incongruent-correct condition for the l image plots (42) of single trials across control participants and attention(RT) and smoothed vertically with a 100-trial moving average.”
Self-citationFear in dreams and in wakefulness: Evidence for day/night affective homeostasis
Sterpenich, V, Perogamvros, L., Tononi, G., & Schwartz, S. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/534099 · Cited by 99
I keep a close watch on this heart of mine: increased interoception in insomnia
Wei, Y., Ramautar, J. R., Colombo, M. A., Stoffers, D., Gómez-Herrero, G., van der Meijden, W. P., te Lindert, B. H. W., van der Werf, Y. D., & Van Someren, E. J. W. (2016) · Sleep · doi:10.5665/sleep.6308 · Cited by 90
Attention-related EEG markers in adult ADHD
Hasler, R., Perroud, N., Meziane, H. B., Herrmann, F., Prada, P., Giannakopoulos, P., & Deiber, M.-P. (2016) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2016.05.008 · Cited by 88
Chuang, C.-H., Chang, K.-Y., Huang, C.-S., & Jung, T.-P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119586 · Cited by 88
Self-citationPlacebo analgesia is not due to compliance or habituation: EEG and behavioural evidence
Watson, A., El-Deredy, W., Vogt, B. A., & Jones, A. K. P. (2007) · NeuroReport · doi:10.1097/wnr.0b013e3280c1e2a8 · Cited by 79
“In each experimental block, vertical and horizontal eye movements were removed using independent component analysis [11] carried out on the continuous EEG data.”
MethodStylianou, M., Murphy, N., Peraza, L. R., Graziadio, S., Cromarty, R., Killen, A., O' Brien, J. T., Thomas, A. J., LeBeau, F. E. N., & Taylor, J.-P. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.013 · Cited by 79
Scalp and Source Power Topography in Sleepwalking and Sleep Terrors: A High-Density EEG Study
Castelnovo, A., Riedner, B. A., Smith, R. F., Tononi, G., Boly, M., & Benca, R. M. (2016) · Sleep · doi:10.5665/sleep.6162 · Cited by 72
Noradrenergic Responsiveness Supports Selective Attention across the Adult Lifespan
Dahl, M. J., Mather, M., Sander, M. C., & Werkle-Bergner, M. (2020) · The Journal of Neuroscience · doi:10.1523/jneurosci.0398-19.2020 · Cited by 72
Deep-Asymmetry: Asymmetry Matrix Image for Deep Learning Method in Pre-Screening Depression
Kang, M., Kwon, H., Park, J.-H., Kang, S., & Lee, Y. (2020) · Sensors · doi:10.3390/s20226526 · Cited by 71
“ICA is an e ff ective method for removing artifacts [22] and has been adopted in previous studies [10].”
MethodPerogamvros, L., Baird, B., Seibold, M., Riedner, B., Boly, M., & Tononi, G. (2017) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01155 · Cited by 70
“Only independent component analysis components with specific activity patterns and component maps characteristic of artifactual activity were removed (Jung et al., 2000).”
Marathe, A. R., Lawhern, V. J., Wu, D., Slayback, D., & Lance, B. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2502323 · Cited by 64
Bianco, V., Berchicci, M., Perri, R. L., Quinzi, F., & Di Russo, F. (2017) · Neuroscience · doi:10.1016/j.neuroscience.2017.07.059 · Cited by 64
Lackner, C. L., Santesso, D. L., Dywan, J., O’Leary, D. D., Wade, T. J., & Segalowitz, S. J. (2018) · Biological Psychology · doi:10.1016/j.biopsycho.2018.01.006 · Cited by 60
Signal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Neuner, I., Arrubla, J., Felder, J., & Shah, N. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.048 · Cited by 48
“Although ICA has been demonstrated to be a powerful tool for the correction of a variety of data artefacts (Iriarte et al., 2003; Jung et al., 2000), it still has the drawback of relying much on the algorithm applied for decomposition.”
Baird, B., Castelnovo, A., Riedner, B. A., Lutz, A., Ferrarelli, F., Boly, M., Davidson, R. J., & Tononi, G. (2018) · eneuro · doi:10.1523/eneuro.0293-18.2018 · Cited by 45
“ICA components with specific activity patterns and component maps characteristic of artifactual activity (ocular, cardiographic, and myogenic) were visually identified and removed (Jung et al., 2000).”
BackgroundLigeza, T. S., Wyczesany, M., Tymorek, A. D., & Kamiński, M. (2016) · Brain Topography · doi:10.1007/s10548-015-0454-2 · Cited by 43
A Generic Transferable EEG Decoder for Online Detection of Error Potential in Target Selection
Bhattacharyya, S., Konar, A., Tibarewala, D. N., & Hayashibe, M. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00226 · Cited by 43
“Next, the EOG artifacts (if any) are removed from the EEG signals through blind source separation using independent component analysis (Jung et al., 2000).”
MethodLucid dreaming occurs in activated rapid eye movement sleep, not a mixture of sleep and wakefulness
Baird, B., Tononi, G., & LaBerge, S. (2022) · Sleep · doi:10.1093/sleep/zsab294 · Cited by 41
Kuusinen, V., Cesnaite, E., Peräkylä, J., Ogawa, K. H., & Hartikainen, K. M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00437 · Cited by 37
“The EEG was down sampled to 250 Hz and filtered with IIR filters to 0.01–70 Hz followed by blink artifact removal by semiautomatic, independent component analysis–based function, method described by Jung et al. (2000).”
MethodInfluentialEmotional context facilitates cortical prediction error responses
Vogel, B. O., Shen, C., & Neuhaus, A. H. (2015) · Human Brain Mapping · doi:10.1002/hbm.22868 · Cited by 37
Abnormal timing of slow wave synchronization processes in non-rapid eye movement sleep parasomnias
Cataldi, J., Stephan, A. M., Marchi, N. A., Haba-Rubio, J., & Siclari, F. (2022) · Sleep · doi:10.1093/sleep/zsac111 · Cited by 33
Dynamic imaging of seizure activity in pediatric epilepsy patients
Lu, Y., Yang, L., Worrell, G. A., Brinkmann, B., Nelson, C., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.021 · Cited by 32
“Components that correspond to artifacts, such as eye blinks and motion artifacts, were removed from the decomposed ICs (Jung et al., 2000).”
BackgroundInfluentialElectrophysiological traces of visuomotor learning and their renormalization after sleep
Landsness, E. C., Ferrarelli, F., Sarasso, S., Goldstein, M. R., Riedner, B. A., Cirelli, C., Perfetti, B., Moisello, C., Ghilardi, M. F., & Tononi, G. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.05.001 · Cited by 31
“Only ICA components with specific activity patterns and component maps characteristic of artifactual activity (Jung et al., 2000; Makeig et al., 1997) were removed.”
BackgroundFranz, M., Nickel, M. M., Ritter, A., Miltner, W. H. R., & Weiss, T. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00070.2015 · Cited by 28
Michelini, G., Cheung, C. H. M., Kitsune, V., Brandeis, D., Banaschewski, T., McLoughlin, G., Asherson, P., Rijsdijk, F., & Kuntsi, J. (2021) · Journal of Attention Disorders · doi:10.1177/1087054718771191 · Cited by 27
“Ocular artifacts were corrected using the infomax Independent Component Analysis (ICA) algorithm (Jung et al., 2000).”
Navid, M. S., Niazi, I. K., Lelic, D., Drewes, A. M., & Haavik, H. (2019) · Sensors · doi:10.3390/s19112610 · Cited by 22
“The ICs were categorized using their spatial distributions (scalp topographies), time courses, spectrograms, event-related potential (ERP) images, and equivalent current dipole models using the guidelines from [24,25] and the website, https://labeling.”
MethodMultimodal person independent recognition of workload related biosignal patterns
Jarvis, J., Putze, F., Heger, D., & Schultz, T. (2011) · Proceedings of the 13th international conference on multimodal interfaces · doi:10.1145/2070481.2070516 · Cited by 19
Campos-Arteaga, G., Forcato, C., Wainstein, G., Lagos, R., Palacios-García, I., Artigas, C., Morales, R., Pedreira, M. E., & Rodríguez, E. (2020) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2020.107279 · Cited by 19
Investigating the Effects of Chiropractic Spinal Manipulation on EEG in Stroke Patients
Navid, M. S., Niazi, I. K., Lelic, D., Nedergaard, R. B., Holt, K., Amjad, I., Drewes, A. M., & Haavik, H. (2020) · Brain Sciences · doi:10.3390/brainsci10050253 · Cited by 18
“The ICs were categorized based on their spatial distribution (scalp topography), time course, spectrograms, event-related potential (ERP) images, and current dipole models using recommendations from [57,58] and the website https://labeling.”
MethodJung, K.-Y., Kim, S. M., Song, J.-Y., Lee, B. U., Lee, C., Lee, S. K., Koo, Y. S., Cho, Y. W., Choi, J. W., & Kim, K. H. (2015) · Sleep Medicine · doi:10.1016/j.sleep.2014.10.025 · Cited by 14
“Independent component analysis was applied to correct stereotyped ocular and muscular artifacts [21].”
MethodCreaser, J. L., Storr, J., & Karl, A. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.765602 · Cited by 9
Kadlaskar, G., Bergmann, S., McNally Keehn, R., Seidl, A., & Keehn, B. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.729270 · Cited by 9
“To date, few researchers have examined tactile responsivity in children with ASD using observational (Foss-Feig et al., 2012; Baranek et al., 2013; Kadlaskar et al., 2019), psychophysical (O’Riordan and Passetti, 2006; Puts et al., 2014; Tavassoli et al., 2016), or neuroimaging methods (Miyazaki et…”
BackgroundPerez, T. M., Glue, P., Adhia, D. B., Navid, M. S., Zeng, J., Dillingham, P., Smith, M., Niazi, I. K., Young, C. K., & De Ridder, D. (2022) · Trials · doi:10.1186/s13063-022-06863-z · Cited by 8
Affective evaluation of errors and neural error processing in obsessive-compulsive disorder
Balzus, L., Jüres, F., Kathmann, N., & Klawohn, J. (2023) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsad022 · Cited by 4
“After downsampling to 500 Hz, independent component analysis (Jung et al., 2000) was used to correct eye movement artifacts.”
MethodQin, Y., Xu, Q., Kujala, T., Wang, X., & Cong, F. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109535 · Cited by 1
Metadata
- Authors
- Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2000-03-01
- Volume
- 37
- Issue
- 2
- Pages
- 163-178
- ISSN
- 0048-5772 (ISSN-L)
- OpenAlex
- W2079277602
- Cited by
- 3,334
- References
- 25
- FWCI
- 12.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.