The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Strategies for the Assessment of Matrix Effect in Quantitative Bioanalytical Methods Based on HPLC−MS/MS
Abstract
In recent years, high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection has been demonstrated to be a powerful technique for the quantitative determination of drugs and metabolites in biological fluids. However, the common and early perception that utilization of HPLC-MS/MS practically guarantees selectivity is being challenged by a number of reported examples of lack of selectivity due to ion suppression or enhancement caused by the sample matrix and interferences from metabolites. In light of these serious method liabilities, questions about how to develop and validate reliable HPLC-MS/MS methods, especially for supporting long-term human pharmacokinetic studies, are being raised. The central issue is what experiments, in addition to the validation data usually provided for the conventional bioanalytical methods, need to be conducted to confirm HPLC-MS/MS assay selectivity and reliability. The current regulatory requirements include the need for the assessment and elimination of the matrix effect in the bioanalytical methods, but the experimental procedures necessary to assess the matrix effect are not detailed. Practical, experimental approaches for studying, identifying, and eliminating the effect of matrix on the results of quantitative analyses by HPLC-MS/MS are described in this paper. Using as an example a set of validation experiments performed for one of our investigational new drug candidates, the concepts of the quantitative assessment of the "absolute" versus "relative" matrix effect are introduced. In addition, experiments for the determination of, the "true" recovery of analytes using HPLC-MS/MS are described eliminating the uncertainty about the effect of matrix on the determination of this commonly measured method parameter. Determination of the matrix effect allows the assessment of the reliability and selectivity of an existing HPLC-MS/MS method. If the results of these studies are not satisfactory, the parameters determined may provide a guide to what changes in the method need to be made to improve assay selectivity. In addition, a direct comparison of the extent of the matrix effect using two different interfaces (a heated nebulizer, HN, and ion spray, ISP) under otherwise the same sample preparation and chromatographic conditions was made. It was demonstrated that, for the investigational drug under study, the matrix effect was clearly observed when ISP interface was utilized but it was absent when the HN interface was employed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
Self-citationBuhrman, D. L., Price, P. I., & Rudewiczcor, P. J. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00072-4 · Cited by 364
Matuszewski, B. K., Chavez-Eng, C. M., & Constanzer, M. L. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00317-x · Cited by 52
Self-citation
Cited by
Peters, F. T., Drummer, O. H., & Musshoff, F. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2006.05.021 · Cited by 1,343
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
(2013) · Journal of Analytical Toxicology · doi:10.1093/jat/bkt054 · Cited by 873
Metabolite profiling: from diagnostics to systems biology
Fernie, A. R., Trethewey, R. N., Krotzky, A. J., & Willmitzer, L. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1451 · Cited by 844
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
Chambers, E., Wagrowski-Diehl, D. M., Lu, Z., & Mazzeo, J. R. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.12.030 · Cited by 776
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Sulyok, M., Berthiller, F., Krska, R., & Schuhmacher, R. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2640 · Cited by 681
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS
Halket, J. M., Waterman, D., Przyborowska, A. M., Patel, R. K. P., Fraser, P. D., & Bramley, P. M. (2005) · Journal of Experimental Botany · doi:10.1093/jxb/eri069 · Cited by 662
Recent advances in high-throughput quantitative bioanalysis by LC–MS/MS
Xu, R. N., Fan, L., Rieser, M. J., & El-Shourbagy, T. A. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.006 · Cited by 530
Ion suppression; A critical review on causes, evaluation, prevention and applications
Furey, A., Moriarty, M., Bane, V., Kinsella, B., & Lehane, M. (2013) · Talanta · doi:10.1016/j.talanta.2013.03.048 · Cited by 521
Vanderford, B. J., & Snyder, S. A. (2006) · Environmental Science & Technology · doi:10.1021/es0613198 · Cited by 457
Sampling root exudates – Mission impossible?
Oburger, E., & Jones, D. L. (2018) · Rhizosphere · doi:10.1016/j.rhisph.2018.06.004 · Cited by 457
Mallet, C. R., Lu, Z., & Mazzeo, J. R. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1276 · Cited by 441
Matrix effects in quantitative pesticide analysis using liquid chromatography–mass spectrometry
Niessen, W. M. A., Manini, P., & Andreoli, R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20097 · Cited by 435
Matrix Effects and Application of Matrix Effect Factor
Zhou, W., Yang, S., & Wang, P. G. (2017) · Bioanalysis · doi:10.4155/bio-2017-0214 · Cited by 430
Sulyok, M., Krska, R., & Schuhmacher, R. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1542-2 · Cited by 409
Rivera-Jaimes, J. A., Postigo, C., Melgoza-Alemán, R. M., Aceña, J., Barceló, D., & López de Alda, M. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.09.134 · Cited by 407
Does a stable isotopically labeled internal standard always correct analyte response?
Wang, S., Cyronak, M., & Yang, E. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2006.08.010 · Cited by 401
Panuwet, P., Hunter, R. E., D'Souza, P. E., Chen, X., Radford, S. A., Cohen, J. R., Marder, M. E., Kartavenka, K., Ryan, P. B., & Barr, D. B. (2016) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.980775 · Cited by 394
Mycosporine-Like Amino Acids: Relevant Secondary Metabolites. Chemical and Ecological Aspects
Carreto, J. I., & Carignan, M. O. (2011) · Marine Drugs · doi:10.3390/md9030387 · Cited by 388
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Midttun, Ø., Hustad, S., & Ueland, P. M. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4013 · Cited by 358
Yang, Y., Lu, L., Zhang, J., Yang, Y., Wu, Y., & Shao, B. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.074 · Cited by 342
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Recent developments in liquid chromatography–mass spectrometry and related techniques
Holčapek, M., Jirásko, R., & Lísa, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.072 · Cited by 330
Matrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometry
Kruve, A., Künnapas, A., Herodes, K., & Leito, I. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.077 · Cited by 322
Capiau, S., Veenhof, H., Koster, R. A., Bergqvist, Y., Boettcher, M., Halmingh, O., Keevil, B. G., Koch, B. C. P., Linden, R., Pistos, C., et al. (2019) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000643 · Cited by 321
Determination of selected organophosphate esters in the aquatic environment of Austria
Martínez-Carballo, E., González-Barreiro, C., Sitka, A., Scharf, S., & Gans, O. (2007) · Science of The Total Environment · doi:10.1016/j.scitotenv.2007.08.005 · Cited by 310
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part I
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.017 · Cited by 300
Learning representations of microbe–metabolite interactions
Morton, J. T., Aksenov, A. A., Nothias, L. F., Foulds, J. R., Quinn, R. A., Badri, M. H., Swenson, T. L., Van Goethem, M. W., Northen, T. R., Vazquez-Baeza, Y., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0616-3 · Cited by 299
Vogeser, M., & Seger, C. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138602 · Cited by 290
Hou, J., Wan, W., Mao, D., Wang, C., Mu, Q., Qin, S., & Luo, Y. (2015) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-3632-y · Cited by 281
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
Recent advances in microextraction by packed sorbent for bioanalysis
Abdel-Rehim, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.053 · Cited by 279
Occurrence and diversity of antibiotic resistance in untreated hospital wastewater
Wang, Q., Wang, P., & Yang, Q. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.10.128 · Cited by 275
Bylda, C., Thiele, R., Kobold, U., & Volmer, D. A. (2014) · The Analyst · doi:10.1039/c4an00094c · Cited by 271
Analysis of Pharmaceuticals in Fish Using Liquid Chromatography-Tandem Mass Spectrometry
Ramirez, A. J., Mottaleb, M. A., Brooks, B. W., & Chambliss, C. K. (2007) · Analytical Chemistry · doi:10.1021/ac062215i · Cited by 264
A review of the pharmaceutical exposome in aquatic fauna
Miller, T. H., Bury, N. R., Owen, S. F., MacRae, J. I., & Barron, L. P. (2018) · Environmental Pollution · doi:10.1016/j.envpol.2018.04.012 · Cited by 262
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Wick, A., Fink, G., & Ternes, T. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.079 · Cited by 262
Tolstikov, V. V., Lommen, A., Nakanishi, K., Tanaka, N., & Fiehn, O. (2003) · Analytical Chemistry · doi:10.1021/ac034716z · Cited by 260
Aptamer-Conjugated Extracellular Nanovesicles for Targeted Drug Delivery
Wan, Y., Wang, L., Zhu, C., Zheng, Q., Wang, G., Tong, J., Fang, Y., Xia, Y., Cheng, G., He, X., et al. (2018) · Cancer Research · doi:10.1158/0008-5472.can-17-2880 · Cited by 259
Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology
Maurer, H. H. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1248-5 · Cited by 257
LITTLE, J., WEMPE, M., & BUCHANAN, C. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.02.011 · Cited by 256
Sulyok, M., Stadler, D., Steiner, D., & Krska, R. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02489-9 · Cited by 253
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Mueller, D. M., Allenspach, M., Othman, A., Saely, C. H., Muendlein, A., Vonbank, A., Drexel, H., & von Eckardstein, A. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.10.091 · Cited by 217
Peitzsch, M., Dekkers, T., Haase, M., Sweep, F. C. G. J., Quack, I., Antoch, G., Siegert, G., Lenders, J. W. M., Deinum, J., Willenberg, H. S., et al. (2015) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2014.10.006 · Cited by 169
Side-chain fluorinated polymer surfactants in biosolids from wastewater treatment plants
Letcher, R. J., Chu, S., & Smyth, S.-A. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.122044 · Cited by 121
Jia, M., Chew, W. M., Feinstein, Y., Skeath, P., & Sternberg, E. M. (2016) · The Analyst · doi:10.1039/c5an02387d · Cited by 113
Neubert, H., Shuford, C. M., Olah, T. V., Garofolo, F., Schultz, G. A., Jones, B. R., Amaravadi, L., Laterza, O. F., Xu, K., & Ackermann, B. L. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz022 · Cited by 109
Perez, E. R., Knapp, J. A., Horn, C. K., Stillman, S. L., Evans, J. E., & Arfsten, D. P. (2016) · Journal of Analytical Toxicology · doi:10.1093/jat/bkv140 · Cited by 106
Munoz, G., Ray, P., Mejia-Avendaño, S., Vo Duy, S., Tien Do, D., Liu, J., & Sauvé, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.06.046 · Cited by 103
Badoud, F., Grata, E., Boccard, J., Guillarme, D., Veuthey, J.-L., Rudaz, S., & Saugy, M. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4779-8 · Cited by 97
Bade, R., Abdelaziz, A., Nguyen, L., Pandopulos, A. J., White, J. M., & Gerber, C. (2020) · Talanta · doi:10.1016/j.talanta.2019.120479 · Cited by 86
Zander, J., Maier, B., Suhr, A., Zoller, M., Frey, L., Teupser, D., & Vogeser, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0746 · Cited by 85
Mass spectrometry and 3‐nitrotyrosine: Strategies, controversies, and our current perspective
Tsikas, D., & Duncan, M. W. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21396 · Cited by 76
Galuska, C. E., Hartmann, M. F., Sánchez-Guijo, A., Bakhaus, K., Geyer, J., Schuler, G., Zimmer, K.-P., & Wudy, S. A. (2013) · The Analyst · doi:10.1039/c3an36817c · Cited by 64
Zhang, T., Sun, H., Gerecke, A. C., Kannan, K., Müller, C. E., & Alder, A. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.05.061 · Cited by 60
Santana-Mayor, Á., Herrera-Herrera, A. V., Rodríguez-Ramos, R., Socas-Rodríguez, B., & Rodríguez-Delgado, M. Á. (2021) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.0c07686 · Cited by 59
Determination of a steroid profile in heel prick blood using LC-MS/MS
Boelen, A., Ruiter, A. F., Claahsen-van der Grinten, H. L., Endert, E., & Ackermans, M. T. (2016) · Bioanalysis · doi:10.4155/bio.16.6 · Cited by 49
Keski‐Rahkonen, P., Huhtinen, K., Desai, R., Tim Harwood, D., Handelsman, D. J., Poutanen, M., & Auriola, S. (2013) · Journal of Mass Spectrometry · doi:10.1002/jms.3252 · Cited by 47
He, X., Kozak, M., & Nimkar, S. (2012) · Analytical Chemistry · doi:10.1021/ac3019476 · Cited by 36
Quantitative analysis of thyroid hormone metabolites in cell culture samples using LC-MS/MS
Rathmann, D., Rijntjes, E., Lietzow, J., & Köhrle, J. (2015) · European Thyroid Journal · doi:10.1159/000430840 · Cited by 34
Kim, B., Lee, M.-N., Park, H.-D., Kim, J. W., Chang, Y. S., Park, W. S., & Lee, S.-Y. (2015) · Annals of Laboratory Medicine · doi:10.3343/alm.2015.35.6.578 · Cited by 32
Bernareggi, A., Grata, E., Pinorini, M., & Conti, A. (2013) · Pharmaceutics · doi:10.3390/pharmaceutics5040621 · Cited by 30
Stout, P. R., Bynum, N. D., Mitchell, J. M., Baylor, M. R., & Ropero-Miller, J. D. (2009) · Journal of Analytical Toxicology · doi:10.1093/jat/33.8.398 · Cited by 29
Metabolites of Heroin in Several Different Post-mortem Matrices
Thaulow, C. H., Øiestad, Å. M. L., Rogde, S., Karinen, R., Brochmann, G. W., Andersen, J. M., Høiseth, G., Handal, M., Mørland, J., Arnestad, M., et al. (2018) · Journal of Analytical Toxicology · doi:10.1093/jat/bky002 · Cited by 27
Richards, K. H., Monk, R., Renko, K., Rathmann, D., Rijntjes, E., & Köhrle, J. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01941-9 · Cited by 27
Sigmund, G., Koch, A., Orlovius, A., Guddat, S., Thomas, A., Schänzer, W., & Thevis, M. (2014) · Drug Testing and Analysis · doi:10.1002/dta.1680 · Cited by 22
Conde-Díaz, A., Santana-Mayor, Á., Herrera-Herrera, A. V., Socas-Rodríguez, B., & Rodríguez-Delgado, M. Á. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.139480 · Cited by 23
Lorenzini, L., Nguyen, N. M., Sacripanti, G., Serni, E., Borsò, M., Saponaro, F., Cecchi, E., Simoncini, T., Ghelardoni, S., Zucchi, R., et al. (2019) · Frontiers in Endocrinology · doi:10.3389/fendo.2019.00088 · Cited by 22
Suberu, J., Gromski, P. S., Nordon, A., & Lapkin, A. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.10.003 · Cited by 19
Patel, D. P., Nair, S., Suhagia, B. N., & Patel, B. M. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.09.005 · Cited by 15
Richards, K. H., Schanze, N., Monk, R., Rijntjes, E., Rathmann, D., & Köhrle, J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0183482 · Cited by 15
Peersman, N., Elslande, J. V., Lepage, Y., De Amicis, S., Desmet, K., & Vermeersch, P. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1237 · Cited by 12
Quality requirements for quantitative clinical chemistry proteomics
(2014) · Translational Proteomics · doi:10.1016/j.trprot.2013.10.001 · Cited by 11
Determination of urinary retinol and creatinine as an early sensitive marker of renal dysfunction
Kučerová, K., Krčmová, L. K., Mikanová, Z., Matysová, L., Melichar, B., & Švec, F. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460390 · Cited by 8
Metadata
- Authors
- Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-06-04
- Volume
- 75
- Issue
- 13
- Pages
- 3019-3030
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2050226999
- Cited by
- 5,335
- References
- 5
- FWCI
- 62.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.