Ion Mobility Mass Spectrometry (IM-MS) for Structural Biology: Insights Gained by Measuring Mass, Charge, and Collision Cross Section
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The investigation of macromolecular biomolecules with ion mobility mass spectrometry (IM-MS) techniques has provided substantial insights into the field of structural biology over the past two decades. An IM-MS workflow applied to a given target analyte provides mass, charge, and conformation, and all three of these can be used to discern structural information. While mass and charge are determined in mass spectrometry (MS), it is the addition of ion mobility that enables the separation of isomeric and isobaric ions and the direct elucidation of conformation, which has reaped huge benefits for structural biology. In this review, where we focus on the analysis of proteins and their complexes, we outline the typical features of an IM-MS experiment from the preparation of samples, the creation of ions, and their separation in different mobility and mass spectrometers. We describe the interpretation of ion mobility data in terms of protein conformation and how the data can be compared with data from other sources with the use of computational tools. The benefit of coupling mobility analysis to activation via collisions with gas or surfaces or photons photoactivation is detailed with reference to recent examples. And finally, we focus on insights afforded by IM-MS experiments when applied to the study of conformationally dynamic and intrinsically disordered proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly accurate protein structure prediction with AlphaFold
Jumper, J., Evans, R., Pritzel, A., Green, T., Figurnov, M., Ronneberger, O., Tunyasuvunakool, K., Bates, R., Žídek, A., Potapenko, A., et al. (2021) · Nature · doi:10.1038/s41586-021-03819-2 · Cited by 43,764
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Interpretation of Shotgun Proteomic Data
Nesvizhskii, A. I., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r500012-mcp200 · Cited by 1,025
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Tabb, D. L., Vega-Montoto, L., Rudnick, P. A., Variyath, A. M., Ham, A.-J. L., Bunk, D. M., Kilpatrick, L. E., Billheimer, D. D., Blackman, R. K., Cardasis, H. L., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr9006365 · Cited by 551
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationA dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Therapeutic protein aggregation: mechanisms, design, and control
Roberts, C. J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.05.005 · Cited by 455
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Complete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371
Hall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267
Kafader, J. O., Melani, R. D., Durbin, K. R., Ikwuagwu, B., Early, B. P., Fellers, R. T., Beu, S. C., Zabrouskov, V., Makarov, A. A., Maze, J. T., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-0764-5 · Cited by 197
Zhou, M., Dagan, S., & Wysocki, V. H. (2013) · The Analyst · doi:10.1039/c2an36525a · Cited by 92
Unique insights to intrinsically disordered proteins provided by ion mobility mass spectrometry
Stuchfield, D., & Barran, P. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2018.01.007 · Cited by 72
Self-citationNative mass spectrometry reveals the conformational diversity of the UVR8 photoreceptor
Camacho, I. S., Theisen, A., Johannissen, L. O., Díaz-Ramos, L. A., Christie, J. M., Jenkins, G. I., Bellina, B., Barran, P., & Jones, A. R. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813254116 · Cited by 54
Self-citationTriple-Stage Mass Spectrometry Unravels the Heterogeneity of an Endogenous Protein Complex
Ben-Nissan, G., Belov, M. E., Morgenstern, D., Levin, Y., Dym, O., Arkind, G., Lipson, C., Makarov, A. A., & Sharon, M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00518 · Cited by 54
Allison, T. M., Barran, P., Cianférani, S., Degiacomi, M. T., Gabelica, V., Grandori, R., Marklund, E. G., Menneteau, T., Migas, L. G., Politis, A., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05791 · Cited by 38
Self-citation
Research works printed but not linked: 374
- 10.1080/14786440208637024 · DOI · Paper page
- 10.1080/14786449808621173 · DOI
- 10.1080/14786441208636004 · DOI
- 10.1016/0003-4916(58)90049-6 · DOI · Paper page
- Mason E. A., 1988, Transport Properties of Ions in Gases, 10.1002/3527602852 · DOI · Paper page
- 10.1021/jacs.5b07913 · DOI
- 10.1038/s41467-019-08897-5 · DOI · Paper page
- 10.1021/ac4038448 · DOI · Paper page
- 10.1021/acs.analchem.9b05130 · DOI
- 10.1016/j.cbpa.2017.10.022 · DOI · Paper page
- 10.1039/C7SC03464D · DOI · Paper page
- 10.1016/S0039-9140(00)00565-8 · DOI · Paper page
- 10.1016/j.fsisyn.2019.07.009 · doi:10.1016/j.fsisyn.2019.07.009
- 10.1021/ac00153a002 · doi:10.1021/ac00153a002
- 10.1021/ac902168a · doi:10.1021/ac902168a
- 10.1021/ac800559h · doi:10.1021/ac800559h
- 10.1134/S1061934811080077 · doi:10.1134/s1061934811080077
- Barnes, B. B.; Snow, N. H. Recent Advances in Sample Preparation for Explosives ; Pawliszyn, J., Ed. Academic Press, 2012; Vol. 3, pp 893–926. · doi:10.1016/b978-0-12-381373-2.00119-8
- 10.1183/13993003.congress-2018.PA4613 · doi:10.1183/13993003.congress-2018.pa4613
- 10.1007/s12127-008-0007-4 · DOI
- 10.3389/fped.2019.00248 · DOI
- 10.1038/s41598-021-99742-7 · DOI
- 10.1080/14789450.2022.2026218 · DOI
- 10.1136/thx.2008.099465 · DOI · Paper page
- 10.1183/23120541.00493-2021 · doi:10.1183/23120541.00493-2021
- 10.1371/journal.pone.0114555 · DOI
- 10.1039/b404531a · DOI · Paper page
- 10.1007/s00216-005-3397-8 · DOI · Paper page
- 10.1039/C8AN02041H · DOI
- 10.1080/10408349008050848 · DOI · Paper page
- 10.1016/0006-291X(81)91304-8 · DOI · Paper page
- 10.1002/bms.1200110409 · doi:10.1002/bms.1200110409
- 10.1038/318162a0 · DOI · Paper page
- 10.1063/1.440991 · DOI · Paper page
- 10.1002/rcm.1290020802 · DOI · Paper page
- 10.1002/rcm.3113 · DOI
- Guan, B.; Cole, R. B. The Background to Electrospray ; Gross, M. L., Caprioli, R. M., Eds. Elsevier, 2016; Vol. 9, pp 132–140. · doi:10.1016/b978-0-08-043848-1.00016-x
- 10.1016/0168-1176(95)04211-3 · DOI · Paper page
- 10.1016/1044-0305(90)85036-L · doi:10.1016/1044-0305(90)85036-l
- 10.1002/(SICI)1096-9888(199706)32:6<577::AID-JMS530>3.0.CO;2-4 · DOI · Paper page
- 10.1021/ac0005619 · DOI · Paper page
- 10.1021/ac00171a028 · DOI · Paper page
- 10.1002/jms.856 · DOI · Paper page
- 10.1021/ac991131p · DOI · Paper page
- 10.1146/annurev.biochem.76.061005.090816 · DOI · Paper page
- 10.1021/ac061039a · DOI · Paper page
- 10.1016/j.jasms.2007.03.031 · DOI
- 10.1021/ja00180a074 · DOI · Paper page
- 10.1002/rcm.1290030706 · DOI
- 10.1016/S0168-1176(96)04478-3 · DOI
- 10.1038/s41467-020-18071-x · DOI · Paper page
- 10.1002/(SICI)1522-2683(19991201)20:18<3551::AID-ELPS3551>3.0.CO;2-2 · DOI · Paper page
- 10.1002/elps.1150190604 · DOI · Paper page
- 10.1002/pmic.201200352 · DOI · Paper page
- 10.1002/pmic.200300612 · doi:10.1002/pmic.200300612
- 10.1002/anie.201210197 · DOI · Paper page
- 10.1016/S1044-0305(98)00027-0 · DOI · Paper page
- 10.1002/rcm.275 · DOI · Paper page
- 10.1002/jms.1599 · DOI · Paper page
- 10.1021/ac300829f · DOI
- 10.1038/s41596-019-0233-8 · DOI
- 10.1016/j.trac.2019.05.035 · DOI
- 10.1063/1.1288235 · doi:10.1063/1.1288235
- 10.1021/acs.analchem.8b02233 · DOI · Paper page
- 10.1021/acs.analchem.0c00649 · DOI
- 10.1021/acs.analchem.9b05124 · DOI
- 10.1021/acs.analchem.1c00402 · DOI
- 10.1021/acs.analchem.2c02215 · DOI
- Gerlich, D. Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions ; Ng, C.Y., Baer, M., Ilya, P., Rice, S. A., Eds. John Wiley & Sons, Ltd, 1992; Vol. 82, pp 1–176. · DOI · Paper page
- 10.1016/j.jasms.2005.06.012 · doi:10.1016/j.jasms.2005.06.012
- 10.1002/rcm.1641 · DOI · Paper page
- 10.1016/j.bbapap.2012.11.013 · DOI · Paper page
- Allison T. M., 2019, Advances in Ion Mobility-Mass Spectrometry: Fundamentals, Instrumentation and Applications, 83, 161, 10.1016/bs.coac.2018.10.001 · DOI
- 10.1016/j.str.2013.08.002 · DOI · Paper page
- 10.1021/acs.analchem.8b05014 · DOI · Paper page
- 10.1002/rcm.8294 · DOI
- 10.1002/rcm.3737 · DOI · Paper page
- 10.1021/acs.analchem.5b01429 · DOI
- 10.1016/j.str.2015.02.010 · DOI · Paper page
- 10.1063/1.475625 · DOI
- 10.1016/0009-2614(96)00941-4 · DOI · Paper page
- 10.1016/j.ijms.2011.06.014 · DOI · Paper page
- 10.1016/S1044-0305(96)00236-X · DOI · Paper page
- 10.1016/j.jcp.2013.05.038 · DOI · Paper page
- 10.1021/acs.jpcb.9b01018 · doi:10.1021/acs.jpcb.9b01018
- 10.1021/ja00091a035 · DOI · Paper page
- 10.1021/jacsau.1c00027 · DOI
- 10.1073/pnas.0913046107 · DOI
- 10.1080/00268970500095998 · DOI
- 10.4155/bio-2016-0244 · DOI
- 10.1073/pnas.1815356116 · DOI
- 10.1021/jacsau.2c00300 · DOI
- 10.1021/acscentsci.8b00879 · DOI · Paper page
- 10.1038/s41467-021-21669-4 · DOI · Paper page
- 10.1007/s11306-007-0081-3 · DOI · Paper page
- 10.1038/nprot.2015.133 · DOI · Paper page
- 10.1038/s41467-018-03309-6 · DOI · Paper page
- 10.1021/acs.jproteome.0c00380 · DOI
- 10.1038/nprot.2017.040 · DOI · Paper page
- 10.1021/pr500880b · DOI · Paper page
- 10.1038/nature01514 · DOI · Paper page
- 10.1021/ac0005619 · DOI · Paper page
- 10.1021/ja012267j · DOI · Paper page
- 10.1002/anie.201005112 · DOI
- 10.1021/jp206867a · DOI · Paper page
- 10.1016/j.jasms.2004.12.018 · DOI
- 10.1002/mas.21462 · DOI
- 10.1021/j150664a002 · DOI · Paper page
- 10.1021/ac9509519 · DOI · Paper page
- 10.1016/S1044-0305(98)00157-3 · DOI · Paper page
- 10.1073/pnas.0807005105 · DOI · Paper page
- 10.1021/ac302789c · DOI · Paper page
- 10.1002/1096-9888(200007)35:7<804::AID-JMS22>3.0.CO;2-Q · DOI · Paper page
- 10.1074/mcp.M111.009407 · DOI · Paper page
- 10.1016/j.jasms.2005.06.011 · DOI · Paper page
- 10.1021/acs.analchem.9b00571 · DOI
- 10.1007/s002160051561 · DOI · Paper page
- 10.1002/anie.201103687 · DOI
- 10.1002/rcm.2182 · doi:10.1002/rcm.2182
- 10.1016/S1044-0305(03)00128-4 · DOI · Paper page
- 10.1039/c0ay00530d · doi:10.1039/c0ay00530d
- 10.1007/s13361-018-1893-2 · DOI
- 10.1016/j.jasms.2004.05.005 · DOI · Paper page
- 10.1016/j.jasms.2008.11.007 · doi:10.1016/j.jasms.2008.11.007
- 10.1007/s13361-014-0965-1 · DOI
- 10.1016/S0003-2670(99)00601-7 · DOI · Paper page
- 10.1002/pmic.201400605 · DOI
- 10.1021/ac5027435 · DOI · Paper page
- 10.1080/14786448208628425 · DOI · Paper page
- 10.1002/anie.201812697 · DOI
- 10.1038/ncomms12163 · DOI · Paper page
- 10.1002/anie.202115047 · DOI
- 10.1021/ac800651b · DOI
- Gabelica V., 2021, New Developments in Mass Spectrometry, 1
- 10.1021/bi971266u · DOI · Paper page
- 10.1021/ac010713f · DOI · Paper page
- 10.1021/jp4097327 · DOI
- 10.1021/acs.analchem.6b01812 · DOI
- 10.1016/j.ijms.2018.01.006 · DOI · Paper page
- 10.1016/S0021-9673(04)01478-5 · doi:10.1016/s0021-9673(04)01478-5 · Paper page
- 10.1021/jacs.5b01338 · DOI · Paper page
- 10.1007/s13361-019-02288-2 · DOI · Paper page
- 10.1021/ac8008143 · doi:10.1021/ac8008143
- 10.1016/S0039-9140(03)00401-6 · doi:10.1016/s0039-9140(03)00401-6
- 10.1021/ac00095a014 · DOI · Paper page
- 10.1021/ac4015066 · DOI
- 10.1021/acs.analchem.9b01838 · DOI · Paper page
- 10.1016/j.ijms.2009.01.012 · DOI · Paper page
- 10.1021/acs.analchem.7b01729 · DOI · Paper page
- 10.1016/j.ijms.2016.11.015 · doi:10.1016/j.ijms.2016.11.015
- 10.1016/S0168-1176(97)00182-1 · DOI
- 10.1063/1.4930604 · doi:10.1063/1.4930604
- 10.1039/C5AN00991J · DOI
- 10.1021/acs.analchem.9b00427 · DOI
- 10.1021/acs.analchem.8b05641 · DOI
- 10.1146/annurev.anchem.1.031207.113001 · DOI · Paper page
- 10.1016/j.jasms.2004.08.003 · DOI · Paper page
- 10.1074/jbc.M503086200 · DOI
- 10.1146/annurev.physchem.51.1.179 · DOI · Paper page
- 10.1016/j.ijms.2009.02.024 · DOI
- 10.1016/j.ijms.2010.01.007 · DOI
- 10.1021/jacs.8b13483 · DOI
- 10.1002/rcm.5013 · DOI · Paper page
- 10.1021/acs.analchem.7b01736 · DOI
- 10.1021/ac1022953 · DOI · Paper page
- 10.1021/acs.analchem.5b01063 · DOI
- 10.1016/j.mcpro.2021.100138 · DOI · Paper page
- 10.1063/1.3665933 · DOI · Paper page
- 10.1007/s13361-014-0999-4 · DOI · Paper page
- 10.1039/C3AN02174B · DOI · Paper page
- 10.1021/acs.analchem.8b01326 · DOI
- 10.1007/s13361-019-02289-1 · doi:10.1007/s13361-019-02289-1
- 10.1007/s13361-015-1326-4 · DOI
- 10.3791/1985 · doi:10.3791/1985
- 10.1021/acs.analchem.0c04948 · DOI
- Richardson K., 2021, New Developments in Mass Spectrometry, 83
- 10.1038/nprot.2008.78 · DOI · Paper page
- 10.1039/C8SC04396E · DOI · Paper page
- 10.1093/bioinformatics/btab429 · DOI
- 10.1021/ac504720m · DOI · Paper page
- 10.1021/jasms.1c00056 · DOI
- 10.1039/C5AN02107C · DOI · Paper page
- 10.1021/ac300212r · doi:10.1021/ac300212r
- 10.1002/rcm.621 · doi:10.1002/rcm.621
- 10.1039/C7AN00031F · DOI · Paper page
- 10.1021/acs.analchem.7b00189 · DOI
- 10.1021/acs.analchem.0c04799 · doi:10.1021/acs.analchem.0c04799
- 10.1021/acs.analchem.8b04518 · DOI
- 10.1007/s13361-012-0517-5 · DOI
- 10.1080/0144235X.2020.1826708 · doi:10.1080/0144235x.2020.1826708
- Knox R., 2021, New Developments in Mass Spectrometry, 402
- 10.1002/anie.201402863 · DOI · Paper page
- Bleiholder C., 2021, New Developments in Mass Spectrometry, 26
- Marklund E. G., 2021, New Developments in Mass Spectrometry, 183
- 10.1039/C0AN00373E · DOI · Paper page
- 10.1007/s13361-013-0724-8 · doi:10.1007/s13361-013-0724-8
- 10.1021/jp312432z · DOI · Paper page
- 10.1080/02786826.2017.1316829 · doi:10.1080/02786826.2017.1316829
- 10.1021/jp961623v · DOI · Paper page
- 10.1021/ac3029008 · DOI
200 of 374 shown
Metadata
- Authors
- Christofi, E., & Barran, P.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2023-02-24
- Volume
- 123
- Issue
- 6
- Pages
- 2902-2949
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W4321765801
- Cited by
- 233
- References
- 26
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Funders
- Engineering and Physical Sciences Research Council (EP/S005226/1, EP/S01778X/1, EP/T019328/1, EP/V038095/1)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.