The challenges and promise of sweat sensing
The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“A fully integrated, battery-powered Bluetooth system using a flexible, multi-plexed sensor array tracked concentrations of several analytes along with temperature 51 (Fig.”
Self-citationGibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 2×
“Sweat analysis of sodium and/or chloride was performed with flame spectrometry or a polarograph 13,14 .”
InfluentialA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308 · cited 3×
“For example, Epi-core Biosystems, more recently spun out of an academic laboratory 52,53 , also initially explored metabolite sensing but, with the advantage Wearable lactate sweat sensor 45 Integrated RFID sodium sensor 49 Integrated sodium sensor with robust flexible–rigid connection 50…”
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862 · cited 2×
“Just before the founding of Eccrine Systems, the startup Electrozyme was spun out of an academic laboratory with the aim of measuring various sweat electrolytes and metabolites, including lactate, which to this day has no established correlation with blood levels 45,46 .”
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839 · cited 1×
“Some studies show correspondence between glucose in sweat and blood, with similar changes from before to after glucose intake for iontophoretic sweat 101 and strong correlations for resting non-stimulated sweat 7,87 .”
Self-citationBandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761 · cited 1×
“3l), among others 62 .”
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Self-citationPhysiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732 · cited 3×
“The enzymatically accessible analytes in sweat are often diluted by one or two orders of magnitude from blood plasma, meaning that not all sensor technologies that work for blood have the precision to properly analyze sweat composition 2,25 .”
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724 · cited 2×
“One well-studied effect is the increase of sodium and chloride with increase in sweat rate due to saturation of reabsorption in the sweat duct 34,35 .”
Self-citationBiology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 7×
“Along with the Epicore Connected Hydration device, another two-component wearable for sodium and fluid loss, success remains to be seen after public reception and external scientific validation (Fig.”
InfluentialImportance of skin temperature in the regulation of sweating.
Nadel, E. R., Bullard, R. W., & Stolwijk, J. A. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.1.80 · Cited by 545
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490 · cited 2×
“Several initial studies pioneered flexible, electrochemical sensors on tattoo-like patches for analytes like lactate, ammonium and sodium, advancing the design of solid-state electrodes and the temporary transfer tattoo platform 45–47 (Fig.”
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479 · cited 1×
“Certain pilot studies have shown promising evidence for the value of dynamic changes in various analytes in sweat, including glucose, cortisol and neuroimmune biomarkers 6–8 .”
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., et al. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00961 · Cited by 446 · cited 3×
“Several promising academic devices have been developed 54,61,74,75 , such as the first continuous-monitoring commercial product, Epicore’s Connected Hydration patch.”
Self-citationA wearable patch for continuous analysis of thermoregulatory sweat at rest
Nyein, H. Y. Y., Bariya, M., Tran, B., Ahn, C. H., Brown, B. J., Ji, W., Davis, N., & Javey, A. (2021) · Nature Communications · doi:10.1038/s41467-021-22109-z · Cited by 437 · cited 6×
“However, recent work has focused on enabling sweat access during everyday activity so as to increase the diversity of users and use cases and, in particular, to monitor dynamic changes over long time periods 32,56 .”
InfluentialSelf-citationAdapting Selected Nucleic Acid Ligands (Aptamers) to Biosensors
Potyrailo, R. A., Conrad, R. C., Ellington, A. D., & Hieftje, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac9802325 · Cited by 426 · cited 1×
“Finally, aptamer sensors are often required to address the analytes of highest interest, in particular, proteins, hormones and drugs 75,88,89 .”
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416 · cited 1×
“…sensor 45 Integrated RFID sodium sensor 49 Integrated sodium sensor with robust flexible–rigid connection 50 Integrated multi-analyte continuous sensing 51 Microfluidic valves for chrono-sampling 53 Simultaneous sweat rate and [Na + ], [K + ], pH measurement 54 Continuous ethanol sensing…”
Self-citationPhysiological Basis of Cystic Fibrosis: A Historical Perspective
QUINTON, P. M. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.1.s3 · Cited by 405 · cited 2×
“Many of these are designed to analyze a single analyte in a single sample (for example, chloride levels for cystic fibrosis and drug tests).”
Baker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403 · cited 1×
“The gold standards in the field for measuring local sweat rate are hygrometry and gravimetry, although these both require trained technicians for device use 73 .”
Nyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388 · cited 4×
“In the academic laboratory or in collaboration with manufacturing facilities, researchers may achieve repeatable results using methods such as roll-to-roll screen printing of electrode designs 78 and use of pipetting robots 98 .”
InfluentialSelf-citationThe physiology, pharmacology, and biochemistry of the eccrine sweat gland
Sato, K. (1977) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0037089 · Cited by 384
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343 · cited 1×
“Just before the founding of Eccrine Systems, the startup Electrozyme was spun out of an academic laboratory with the aim of measuring various sweat electrolytes and metabolites, including lactate, which to this day has no established correlation with blood levels 45,46 .”
Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601355 · Cited by 315 · cited 2×
“For example, Epi-core Biosystems, more recently spun out of an academic laboratory 52,53 , also initially explored metabolite sensing but, with the advantage Wearable lactate sweat sensor 45 Integrated RFID sodium sensor 49 Integrated sodium sensor with robust flexible–rigid connection 50…”
Methylxanthine Drug Monitoring with Wearable Sweat Sensors
Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707442 · Cited by 310 · cited 2×
“Importantly, ethanol and other exogenous compounds also have zero baseline concentration in sweat and therefore can be detected with high certainty for applications such as drug dosing and drug-abuse monitoring 57,58 .”
Self-citationReeder, J. T., Choi, J., Xue, Y., Gutruf, P., Hanson, J., Liu, M., Ray, T., Bandodkar, A. J., Avila, R., Xia, W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau6356 · Cited by 308 · cited 1×
“Second, the device should also keep the sample free from contamination, whether from the epidermis, in particular, when cells are sloughed off of the skin 69 , or from the environment, for example, during aquatic activities 70 .”
Touch‐Based Stressless Cortisol Sensing
Tang, W., Yin, L., Sempionatto, J. R., Moon, J., Teymourian, H., & Wang, J. (2021) · Advanced Materials · doi:10.1002/adma.202008465 · Cited by 302 · cited 1×
“The former presents unobtrusive analyses of endogenous biomarker concentrations but with the possible challenge of greater variability in sweat rate 65 .”
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294 · cited 1×
“For example, the startup Eccrine Systems, of which one of us (J.H.) was a cofounder, aimed to measure electrolytes in sweat but later found electrolytes to have limited utility beyond simply reflecting the sweat-secretion rate 2,63 .”
Self-citationStretchable, Wireless Sensors and Functional Substrates for Epidermal Characterization of Sweat
Huang, X., Liu, Y., Chen, K., Shin, W., Lu, C., Kong, G., Patnaik, D., Lee, S., Cortes, J. F., & Rogers, J. A. (2014) · Small · doi:10.1002/smll.201400483 · Cited by 282 · cited 1×
“Others developed colorimetric sensors, such as a microporous patch with capacitive electrodes for volumetric sweat measurement and optical sensing of ions and pH 48 .”
Fluid and electrolyte supplementation for exercise heat stress
Sawka, M. N., & Montain, S. J. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/72.2.564s · Cited by 280 · cited 1×
“The reproducibility of sensor responses within and across batches is also important because subject studies at scale will require large numbers of sensors to (dis)prove any physiological correlations.”
Baker, L. B., Model, J. B., Barnes, K. A., Anderson, M. L., Lee, S. P., Lee, K. A., Brown, S. D., Reimel, A. J., Roberts, T. J., Nuccio, R. P., et al. (2020) · Science Advances · doi:10.1126/sciadv.abe3929 · Cited by 243 · cited 6×
“Whole-body fluid loss can be predicted from local sweating rates 43,78 , making key information accessible for managing both hydration and electrolyte balance, as electrolyte losses can generally be recovered by simply replacing fluid losses with a standard sports drink 79 .”
InfluentialLi, H., Dauphin-Ducharme, P., Ortega, G., & Plaxco, K. W. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b05412 · Cited by 233 · cited 1×
“Ratiometric measurement has also been demonstrated for calibration-free operation of electrochemical aptamer-based biosensors 95 .”
Kwon, K., Kim, J. U., Deng, Y., Krishnan, S. R., Choi, J., Jang, H., Lee, K., Su, C.-J., Yoo, I., Wu, Y., et al. (2021) · Nature Electronics · doi:10.1038/s41928-021-00556-2 · Cited by 230 · cited 4×
“Several promising academic devices have been developed 54,61,74,75 , such as the first continuous-monitoring commercial product, Epicore’s Connected Hydration patch.”
InfluentialHyperhidrosis: an update on prevalence and severity in the United States
Doolittle, J., Walker, P., Mills, T., & Thurston, J. (2016) · Archives of Dermatological Research · doi:10.1007/s00403-016-1697-9 · Cited by 221 · cited 1×
“…applications of sweat rate include some widespread and others rare but grave, including hyperhidrosis in an estimated 5% of the US population 80 , diabetic neuropathy, regional paralysis in patients suffering from stroke 81 , defects of the central nervous system in infants 82 and other…”
Compilation of 222 drugs’ plasma protein binding data and guidance for study designs
Zhang, F., Xue, J., Shao, J., & Jia, L. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.12.018 · Cited by 220 · cited 1×
“…requirements are high because many hormones and drugs bind at high proportions to large proteins in circulation, and these complexes cannot easily partition into sweat by either passive transcellular or paracellular permeation, including some half of common drugs at a 90–100% binding rate 2,90 .”
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208 · cited 1×
“Certain pilot studies have shown promising evidence for the value of dynamic changes in various analytes in sweat, including glucose, cortisol and neuroimmune biomarkers 6–8 .”
Sempionatto, J. R., Moon, J.-M., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00139 · Cited by 208 · cited 4×
“There has also been innovation in sweat collection, including non-stimulated sweat, as well as long-lasting chemical sweat stimulation 7,32,56 .”
InfluentialMechanisms and controllers of eccrine sweating in humans
Crandall, C. G. (2010) · Frontiers in Bioscience · doi:10.2741/s94 · Cited by 202 · cited 3×
“Another clinically established test is the thermoregulatory sweat test, which uses a colorimetric powder for qualitative whole-body sweat monitoring 1 .”
InfluentialWiorek, A., Parrilla, M., Cuartero, M., & Crespo, G. A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02211 · Cited by 201 · cited 1×
“This conflicting evidence does not preclude the possibility of finding a reliable correlation after correcting sensor readings for fluctuations in temperature and pH 103 , involving a relationship with sweat-secretion rate, accounting for an absorptive–metabolic Box 1”
Cystic Fibrosis: Lessons from the Sweat Gland
Quinton, P. M. (2007) · Physiology · doi:10.1152/physiol.00041.2006 · Cited by 198 · cited 1×
“…two layers of cells, basal and luminal ductal cells, and it serves primarily an active electrolyte-reabsorptive function, which at low sweat rates brings the concentrations of sodium and chloride six to eight times lower than those present in plasma to render the secreted sweat hypotonic 26 .”
Control of thermoregulatory sweating is altered by hydration level and exercise intensity
Montain, S. J., Latzka, W. A., & Sawka, M. N. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.5.1434 · Cited by 186 · cited 1×
“For hydration, while self-assessment may be sufficient in most cases, during exercise in the heat, the sensation of thirst is known to be an unreliable indicator, in many cases leading to incomplete rehydration 76,77 .”
Neural control of sweat secretion: a review
Hu, Y., Converse, C., Lyons, M. C., & Hsu, W. H. (2018) · British Journal of Dermatology · doi:10.1111/bjd.15808 · Cited by 181 · cited 1×
“One last distinct class of natural sweating, primarily seen in apocrine sweat glands and uniquely mediated by adrenergic receptors, is triggered by stress or other strong emotions 31 .”
Wearable Sweat Band for Noninvasive Levodopa Monitoring
Tai, L.-C., Liaw, T. S., Lin, Y., Nyein, H. Y. Y., Bariya, M., Ji, W., Hettick, M., Zhao, C., Zhao, J., Hou, L., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02478 · Cited by 177
Self-citationCalibration-free potentiometric sensing with solid-contact ion-selective electrodes
Rousseau, C. R., & Bühlmann, P. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116277 · Cited by 172 · cited 3×
“Recently, much work has been done toward calibration-free readout of ion concentrations from their Nernstian signal voltages; recommendations for reproducibility include the use of a redox buffer to define the redox potential with its two states in close concentrations and, for long-term stability, the incorporation o…”
EXCRETION OF SODIUM AND POTASSIUM IN HUMAN SWEAT 1
Schwartz, I. L., & Thaysen, J. H. (1956) · Journal of Clinical Investigation · doi:10.1172/jci103245 · Cited by 166 · cited 1×
“Another sweat-sensing product cleared by the US Food and Drug Administration (FDA) is the PharmChek Sweat Patch, developed in 1990, which is a sweat-collection device providing court-admissible evidence intended for drug-abuse detection (Fig.”
A new simple method for assessing sudomotor function: Relevance in type 2 diabetes
Mayaudon, H., Miloche, P.-O., & Bauduceau, B. (2010) · Diabetes & Metabolism · doi:10.1016/j.diabet.2010.05.004 · Cited by 164 · cited 1×
“…and quicker process for clinicians, the SUDOSCAN device assesses sudomotor function via electrochemical skin conductance, https://doi.org/10.1038/s41587-023-02059-1 a measure of the conductance at the hands and feet during electrical stimulation across an array of direct-current voltages 42 (Fig.”
InfluentialReview—Electrochemistry and Other Emerging Technologies for Continuous Glucose Monitoring Devices
Das, S. K., Nayak, K. K., Krishnaswamy, P. R., Kumar, V., & Bhat, N. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac7abb · Cited by 163 · cited 1×
“This conflicting evidence does not preclude the possibility of finding a reliable correlation after correcting sensor readings for fluctuations in temperature and pH 103 , involving a relationship with sweat-secretion rate, accounting for an absorptive–metabolic Box 1”
A wearable sensor for the detection of sodium and potassium in human sweat during exercise
Pirovano, P., Dorrian, M., Shinde, A., Donohoe, A., Brady, A. J., Moyna, N. M., Wallace, G., Diamond, D., & McCaul, M. (2020) · Talanta · doi:10.1016/j.talanta.2020.121145 · Cited by 158 · cited 1×
“In the academic laboratory or in collaboration with manufacturing facilities, researchers may achieve repeatable results using methods such as roll-to-roll screen printing of electrode designs 78 and use of pipetting robots 98 .”
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc01082j · Cited by 156 · cited 4×
“The enzymatically accessible analytes in sweat are often diluted by one or two orders of magnitude from blood plasma, meaning that not all sensor technologies that work for blood have the precision to properly analyze sweat composition 2,25 .”
InfluentialSelf-citationAnti-Biofouling Strategies for Long-Term Continuous Use of Implantable Biosensors
Xu, J., & Lee, H. (2020) · Chemosensors · doi:10.3390/chemosensors8030066 · Cited by 154 · cited 1×
“…molecules that are the most promising analytes in sweat, fouling may not be a serious issue, as robust size exclusion membrane protection can be used against albumin and the other large and most problematic foulants, as is done in commercial subcutaneous continuous glucose monitors (CGMs) 93,94 .”
Montagna, W., Kligman, A. M., & Carlisle, K. S. (1992) · Springer eBooks · doi:10.1007/978-1-4613-9202-6 · Cited by 150
‘SWEATCH’: A Wearable Platform for Harvesting and Analysing Sweat Sodium Content
Glennon, T., O'Quigley, C., McCaul, M., Matzeu, G., Beirne, S., Wallace, G. G., Stroiescu, F., O'Mahoney, N., White, P., & Diamond, D. (2016) · Electroanalysis · doi:10.1002/elan.201600106 · Cited by 147 · cited 1×
“A highly engineered arm band sodium sensor brought together robust mechanical and electrical design 50 (Fig.”
Watkins, Z., Karajić, A., Young, T., White, R. J., & Heikenfeld, J. C. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02403 · Cited by 143 · cited 2×
“This conflicting evidence does not preclude the possibility of finding a reliable correlation after correcting sensor readings for fluctuations in temperature and pH 103 , involving a relationship with sweat-secretion rate, accounting for an absorptive–metabolic Box 1”
Self-citationFrom the beaker to the body: translational challenges for electrochemical, aptamer-based sensors
Arroyo-Currás, N., Dauphin-Ducharme, P., Scida, K., & Chávez, J. L. (2020) · Analytical Methods · doi:10.1039/d0ay00026d · Cited by 129 · cited 1×
“Findings of either absent correlations or strong correlations between sweat and blood serum should be viewed as equally impactful: one will help the field to avoid pursuing a non-existent channel of information, the other to focus on one with value.”
ELECTROLYTE ABNORMALITIES OF THE SWEAT IN FIBROCYSTIC DISEASE OF THE PANCREAS°
Darling, R. C., diSant’Agnese, P. A., Perera, G. A., & Andersen, D. H. (1953) · The American Journal of the Medical Sciences · doi:10.1097/00000441-195301000-00011 · Cited by 125 · cited 2×
“In the 1950s, the observation of elevated sweat chloride accompanying cystic fibrosis was quantitatively verified 12 , and the diagnostic method was overhauled by pediatricians, who used sweat-collection techniques involving absorbent pads of gauze and filter paper and collection vessels made of…”
Sweat testing for cocaine, codeine and metabolites by gas chromatography–mass spectrometry
Huestis, M. A., Oyler, J. M., Cone, E. J., Wstadik, A. T., Schoendorfer, D., & Joseph, R. E. (1999) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00246-7 · Cited by 125 · cited 1×
“…in sweat remained high even while other wearables in the consumer market stagnated because they reused the same standard set of optical and physical measurements, namely pedometry, pulse and perhaps blood oxygen saturation, whereas sweat promised access to new, deep physiological information.”
Shaver, A., Curtis, S. D., & Arroyo‐Currás, N. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22385 · Cited by 120 · cited 1×
“Findings of either absent correlations or strong correlations between sweat and blood serum should be viewed as equally impactful: one will help the field to avoid pursuing a non-existent channel of information, the other to focus on one with value.”
Psychological Sweating: A Systematic Review Focused on Aetiology and Cutaneous Response
Harker, M. (2013) · Skin Pharmacology and Physiology · doi:10.1159/000346930 · Cited by 117 · cited 1×
“Additionally, dynamic changes in sweat rate can provide insight into psychological stress, anxiety or pain, with applications in healthcare, education and human–computer interaction that have not yet been fully explored 56,83,84 .”
Lin, S., Wang, B., Zhao, Y., Shih, R., Cheng, X., Yu, W., Hojaiji, H., Lin, H., Hoffman, C., Ly, D., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.9b01727 · Cited by 114 · cited 1×
“These interfacing films are designed with a few key characteristics: hydrophilicity and, in some cases, porosity for sweat uptake from the skin by wetting properties and capillary forces as well as minimal thickness for a quick sensor response time 7,56,66 .”
Self-citationSimmers, P., Li, S. K., Kasting, G. B., & Heikenfeld, J. C. (2017) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2017.10.013 · Cited by 107 · cited 4×
“Some of the more powerful and slowly metabolized sweat stimulants, such as carbachol, have been demonstrated to generate local sweating for a remarkably long duration of 2–3 d, with multiple low-dose or single higher-dose treatments 32 .”
InfluentialSelf-citationElectrolyte abnormalities of the sweat in fibrocystic disease of the pancreas.
Darling, R. C., diSant’Agnese, P. A., Perera, G. A., et al. (1953) · PubMed · Cited by 106
(2003) · Seminars in Neurology · doi:10.1055/s-2004-817724 · Cited by 105 · cited 2×
“…sweat rate include some widespread and others rare but grave, including hyperhidrosis in an estimated 5% of the US population 80 , diabetic neuropathy, regional paralysis in patients suffering from stroke 81 , defects of the central nervous system in infants 82 and other autonomic dysfunctions 83 .”
Yuan, Z., Hou, L., Bariya, M., Nyein, H. Y. Y., Tai, L., Ji, W., Li, L., & Javey, A. (2019) · Lab on a Chip · doi:10.1039/c9lc00598f · Cited by 105 · cited 1×
“Selectivity and protection from biofouling are also key; sensors may face interference from changes in pH, temperature and other analytes, as well as blockage by accumulated macromolecules or microorganisms.”
Self-citationMoon, J., Teymourian, H., De la Paz, E., Sempionatto, J. R., Mahato, K., Sonsa‐ard, T., Huang, N., Longardner, K., Litvan, I., & Wang, J. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202106674 · Cited by 103 · cited 1×
“For example, the profile of levodopa was continuously tracked through its metabolism with possible relevance for the management of Parkinson’s disease 58,105 , and the profile of caffeine, a methylxanthine drug, was monitored after consumption of espresso 57 .”
Korpelainen, J. T., Sotaniemi, K. A., & Myllylä, V. V. (1993) · Neurology · doi:10.1212/wnl.43.6.1211 · Cited by 88
Eccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S. (2018) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201800010 · Cited by 86
Klous, L., de Ruiter, C. J., Scherrer, S., Gerrett, N., & Daanen, H. A. M. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04562-8 · Cited by 86 · cited 1×
“Other studies report a lack of a correlation in time-averaged glucose levels for iontophoretic sweat across fasting populations of healthy and diabetic individuals 78 and for exercise-stimulated sweat in healthy individuals at 60% and 80% of maximal heart rate 102 .”
(1979) · PubMed · Cited by 81
Pulsatile Sweating and Sympathetic Sudomotor Activity.
Ogawa, T., & Sugenoya, J. (1993) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.43.275 · Cited by 80 · cited 1×
“This may be in part due to contraction of myoepithelial cells but is mostly driven by sympathetic sudomotor discharge and resulting activation of cholinergic receptors 20,23 .”
Recent progress in the development of improved reference electrodes for electrochemistry
Troudt, B. K., Rousseau, C. R., Dong, X. I. N., Anderson, E. L., & Bühlmann, P. (2021) · Analytical Sciences · doi:10.2116/analsci.21sar11 · Cited by 80 · cited 1×
“This conflicting evidence does not preclude the possibility of finding a reliable correlation after correcting sensor readings for fluctuations in temperature and pH 103 , involving a relationship with sweat-secretion rate, accounting for an absorptive–metabolic Box 1”
Sweat induction from an isolated eccrine sweat gland
Sato, K. (1973) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1973.225.5.1147 · Cited by 79 · cited 1×
“…science of sweat analyte partitioning and possible application for casual health monitoring; however, sweat glucose monitoring will arguably never attain the accuracy of wearable indwelling needle or micronee-dle sensors in interstitial fluid or blood glucose meter readings for medical purposes.”
Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat
Bhide, A., Muthukumar, S., Saini, A., & Prasad, S. (2018) · Scientific Reports · doi:10.1038/s41598-018-24543-4 · Cited by 76 · cited 2×
“Correlation is disproven for some analytes (for example, lactate), not certain for some (for example, glucose) and significant for others (for example, ethanol) 55,87 .”
(2017) · PubMed Central · Cited by 76
Paul, B., Demuru, S., Lafaye, C., Saubade, M., & Briand, D. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000910 · Cited by 74 · cited 1×
“Pilocarpine, an FDA-approved sweat stimulant, has been integrated into numerous wearable-device demonstrations, and emerging stimulants show promise for continuous, multi-day sweat measurement 32,55,67,68 .”
Ultra-simple wearable local sweat volume monitoring patch based on swellable hydrogels
Zhao, F. J., Bonmarin, M., Chen, Z. C., Larson, M., Fay, D., Runnoe, D., & Heikenfeld, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00911f · Cited by 71 · cited 1×
“Before on-body use, sensors should be calibrated to stock concentrations of their target biomarker to yield measurements in units of absolute concentration rather than just relative change.”
Self-citationA Wearable Device for Monitoring Sweat Rates via Image Analysis
Matzeu, G., Fay, C., Vaillant, A., Coyle, S., & Diamond, D. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2477676 · Cited by 63 · cited 1×
“New, fully integrated devices included a compact, inductively powered, radio frequency identification platform in Band-Aid form factor for discrete ion measurements 49 (Fig.”
Forlenza, G. P., Kushner, T., Messer, L. H., Wadwa, R. P., & Sankaranarayanan, S. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0401 · Cited by 63 · cited 1×
“For example, the Dexcom G6 commercial CGM uses a nonlinear, time-dependent sensitivity function calibrated to each production batch to reliably translate sensor signal to glucose concentration for 10 d with no user calibration 99 .”
A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring
Brueck, A., Iftekhar, A. T., Stannard, A. B., Yelamarthi, K., & Kaya, T. (2018) · Sensors · doi:10.3390/s18020533 · Cited by 59 · cited 1×
“These products laid the groundwork for reproducible sweat-collection technology, with many academic studies using and building on the Macroduct to this day 39–41 .”
Laboratory Diagnosis of Cystic Fibrosis
Webster, H. L., & Rundell, C. A. (1982) · CRC Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368209085074 · Cited by 55
Wang, S., Liu, M., Yang, X., Lu, Q., Xiong, Z., Li, L., Zheng, H., Feng, S., & Zhang, T. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114351 · Cited by 52 · cited 2×
“Several promising academic devices have been developed 54,61,74,75 , such as the first continuous-monitoring commercial product, Epicore’s Connected Hydration patch.”
Harshman, S. W., Pitsch, R. L., Smith, Z. K., O’Connor, M. L., Geier, B. A., Qualley, A. V., Schaeublin, N. M., Fischer, M. V., Eckerle, J. J., Strang, A. J., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0203133 · Cited by 51 · cited 1×
“In another vein, proteomic and metabolomic analyses began to lay the groundwork for broader biocomposition studies 60 .”
Open nanofluidic films with rapid transport and no analyte exchange for ultra-low sample volumes
Twine, N. B., Norton, R. M., Brothers, M. C., Hauke, A., Gomez, E. F., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00186c · Cited by 43 · cited 1×
“The enzymatically accessible analytes in sweat are often diluted by one or two orders of magnitude from blood plasma, meaning that not all sensor technologies that work for blood have the precision to properly analyze sweat composition 2,25 .”
Self-citationMoyen, N. E., Bapat, R. C., Tan, B., Hunt, L. A., Jay, O., & Mündel, T. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182413126 · Cited by 38 · cited 1×
“Another startup, Kenzen, initially focused on wearables for continuous measurement of sweat volume and electrolyte loss but pivoted to measurement of body temperature 64 .”
Tape‐Free, Digital Wearable Band for Exercise Sweat Rate Monitoring
Dautta, M., Ayala‐Cardona, L. F., Davis, N., Aggarwal, A., Park, J., Wang, S., Gillan, L., Jansson, E., Hietala, M., Ko, H., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201187 · Cited by 37 · cited 1×
“Rigid, flexible, adhesive and smooth materials each offer different advantages 43,100 .”
Self-citationSouza, S. L., Graça, G., & Oliva, A. (2018) · Skin Research and Technology · doi:10.1111/srt.12412 · Cited by 34 · cited 1×
“It has been observed that, at matching flow rates, pharmacological sweat contains significantly higher concentrations of potassium and sometimes sodium than thermal sweat but similar concentrations of lactate and several other metabolites 17,33 .”
The time course of the decline in sweating produced by wetting the skin
Brebner, D. F., & Kerslake, D. M. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007518 · Cited by 34 · cited 1×
“Hydromeiosis is an effect seen across the whole body but in particular on the palms and areas with thicker skin, where exposure to water or dilute salty sweat leads to swelling of the epidermis and blockage of sweat ducts 71 .”
Autonomic testing, methods and techniques
Illigens, B. M. W., & Gibbons, C. H. (2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00028-x · Cited by 33
Origin of periodic acid-Schiff-reactive glycoprotein in human eccrine sweat
Yanagawa, S., Yokozeki, H., & Sato, K. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.5.1615 · Cited by 26 · cited 2×
“Evidence for dark cells releasing glycoproteins of varying sizes from granular contents was provided by a combination of histochemical staining and antibody binding 21 .”
Yuan, Y., DeBrosse, M. C., Brothers, M. C., Kim, S. S., Sereda, A., Ivanov, N. V., Hussain, S. M., & Heikenfeld, J. C. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c14175 · Cited by 23 · cited 2×
“However, new strategies are being developed to improve sensor selectivity and longevity, with a recent report of week-long sensor operation in serum at bodily temperature 91–93 .”
Self-citationHigh-frequency pulsatile discharge of human sweat glands: myoepithelial mechanism
Nicolaı̈dis, S., & Sivadjian, J. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.32.1.86 · Cited by 22 · cited 1×
“Sweat is naturally produced in pulses at a frequency of 12–21 cycles per second 22 .”
Baker, L. B., King, M. A., Keyes, D. M., Brown, S. D., Engel, M. D., Seib, M. S., Aranyosi, A. J., & Ghaffari, R. (2022) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2022-0017 · Cited by 17 · cited 2×
“Its measurements of regional sweat loss on the forearm have been shown to correlate with whole-body sweat loss and can help assess hydration status 43,44 .”
A Simple Non-Contact Optical Method to Quantify In-Vivo Sweat Gland Activity and Pulsation
Drexelius, A., Fehr, D., Vescoli, V., Heikenfeld, J. C., & Bonmarin, M. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3151938 · Cited by 15 · cited 3×
“Many of these are designed to analyze a single analyte in a single sample (for example, chloride levels for cystic fibrosis and drug tests).”
Self-citationMoon, J., Teymourian, H., la Paz, E. D., Sempionatto, J. R., Mahato, K., Sonsa‐ard, T., Huang, N., Longardner, K., Litvan, I., & Wang, J. (2021) · Angewandte Chemie · doi:10.1002/ange.202106674 · Cited by 13
Ruwe, T., White, E., Zebertavage, A. S., Runnoe, D., Fay, D., Daumeyer, H., Tracy, T. S., Uchtman, K. F., Begtrup, G., Yuan, Y., et al. (2023) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000001110 · Cited by 13 · cited 1×
“These well-financed but thus far largely unsuccessful commercial ventures highlight the nuanced profile of the information in sweat and current challenges in the field.”
Self-citation
Cited by
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
Spinelli, J. C., Suleski, B. J., Wright, D. E., Grow, J. L., Fagans, G. R., Buckley, M. J., Yang, D. S., Yang, K., Beil, S. M., Wallace, J. C., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01466-9 · Cited by 44
“Recent advances in electrochemical sensors and miniaturized bioe-lectronics have enabled real-time and non-invasive measurement of sweat dynamics and biomarkers associated with hydration status 26 – 33 , disease progression 34 , metabolic and hormonal status 35 – 37 , and stress 38,39 .”
Metadata
- Authors
- Davis, N., Heikenfeld, J., Milla, C., & Javey, A.
- Venue
- Nature Biotechnology
- Published
- 2024-01-11
- Volume
- 42
- Issue
- 6
- Pages
- 860-871
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W4390751412
- Cited by
- 211
- References
- 94
- FWCI
- 22.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.