A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Open accessThe DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Abstract
We report a new method for the real-time quantitative analysis of sodium in human sweat, consolidating sweat collection and analysis in a single, integrated, wearable platform. This temporal data opens up new possibilities in the study of human physiology, broadly applicable from assessing high performance athletes to monitoring Cystic Fibrosis (CF) sufferers. Our compact Sodium Sensor Belt (SSB) consists of a sodium selective Ion Selective Electrode (ISE) integrated into a platform that can be interfaced with the human body during exercise. No skin cleaning regime or sweat storage technology is required as the sweat is continually wicked from the skin to a sensing surface and from there to a storage area via a fabric pump. Our results suggest that after an initial equilibration period, a steady-state sodium plateau concentration was reached. Atomic Absorption Spectroscopy (AAS) was used as a reference method, and this has confirmed the accuracy of the new continuous monitoring approach. The steady-state concentrations observed were found to fall within ranges previously found in the literature, which further validates the approach. Daily calibration repeatability (n = 4) was ±3.0% RSD and over a three month period reproducibility was ±12.1% RSD (n = 56). As a further application, we attempted to monitor the sweat of Cystic Fibrosis (CF) sufferers using the same device. We observed high sodium concentrations symptomatic of CF (∼60 mM Na+) for two CF patients, with no conclusive results for the remaining patients due to their limited exercising capability, and high viscosity/low volume of sweat produced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exercise and Fluid Replacement
(2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802ca597 · Cited by 1,497
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Shirreffs, S. M., & Maughan, R. J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.336 · Cited by 251
Calixarene-based sensing agents
Diamond, D., & McKervey, M. A. (1996) · Chemical Society Reviews · doi:10.1039/cs9962500015 · Cited by 247
Self-citationBio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S., Wu, Y., Lau, K. T., Wallace, G., & Diamond, D. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 235
Self-citationSolid-contact polymeric membrane electrodes with detection limits in the subnanomolar range
Sutter, J., Radu, A., Peper, S., Bakker, E., & Pretsch, E. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.07.016 · Cited by 211
Solid Contact Potentiometric Sensors for Trace Level Measurements
Chumbimuni-Torres, K. Y., Rubinova, N., Radu, A., Kubota, L. T., & Bakker, E. (2006) · Analytical Chemistry · doi:10.1021/ac050749y · Cited by 206
Fluids and hydration in prolonged endurance performance
von Duvillard, S. P., Braun, W. A., Markofski, M., Beneke, R., & Leithäuser, R. (2004) · Nutrition · doi:10.1016/j.nut.2004.04.011 · Cited by 186
Peer Reviewed: Calixarenes: Designer Ligands for Chemical Sensors
Diamond, D., & Nolan, K. (2001) · Analytical Chemistry · doi:10.1021/ac012376g · Cited by 172
Self-citation
Research works printed but not linked: 2
- Northall, 1995, British Journal of Biomedical Science, 52, 68
- Legrys, 1994, Archives of Pathology & Laboratory Medicine, 118, 865
Cited by
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
“have been used to measure analytes of interest (Supplementary Table 1) 14–18 .”
MethodBariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
“Ag/AgCl electrodes were chosen for chloride ion detection (23) whereas the measurement of sodium ions was achieved by using previously reported sodium ionophore X selectophore-based ion-selective electrodes (15).”
MethodWearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 764
An Overview of the Development of Flexible Sensors
Han, S., Peng, H., Sun, Q., Venkatesh, S., Chung, K., Lau, S. C., Zhou, Y., & Roy, V. A. L. (2017) · Advanced Materials · doi:10.1002/adma.201700375 · Cited by 771
Bandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., et al. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00961 · Cited by 446
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
“Compared to the previously reported non-invasive sweat sensors (Jia et al. 2013; Rose et al. 2015; Schazmann et al. 2010), we developed a fully integrated system for continuous and simultaneous detection of several physiological parameters inside a passively-activated microfluidic system.”
MethodWearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Bandodkar, A. J., You, J.-M., Kim, N.-H., Gu, Y., Kumar, R., Mohan, A. M. V., Kurniawan, J., Imani, S., Nakagawa, T., Parish, B., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00865a · Cited by 412
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
Wearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 330
Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids
Gao, W., Nyein, H. Y. Y., Shahpar, Z., Fahad, H. M., Chen, K., Emaminejad, S., Gao, Y., Tai, L.-C., Ota, H., Wu, E., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00287 · Cited by 391
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
“For instance, sweat glucose (82–84), ethanol (85, 86), chloride (79), sodium (87), cortisol (88), and lactate (89) levels provide information on glycemic conditions, stress, physical fatigue, and dehydration.”
BackgroundWearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
“[39,107,118,119]”
BackgroundInfluentialWearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346
Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis
Yu, Y., Nyein, H. Y. Y., Gao, W., & Javey, A. (2020) · Advanced Materials · doi:10.1002/adma.201902083 · Cited by 349
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Bandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Recent Progress of Self‐Powered Sensing Systems for Wearable Electronics
Lou, Z., Li, L., Wang, L., & Shen, G. (2017) · Small · doi:10.1002/smll.201701791 · Cited by 309
Tattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 312
Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601355 · Cited by 315
Advanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Self-citationProgress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Khan, S., Ali, S., & Bermak, A. (2019) · Sensors · doi:10.3390/s19051230 · Cited by 253
“One such development was reported, presenting breathable and stretchable temperature sensors inspired by human skin [126].”
BackgroundElectronic Tongue—A Tool for All Tastes?
Podrażka, M., Bączyńska, E., Kundys, M., Jeleń, P., & Witkowska Nery, E. (2017) · Biosensors · doi:10.3390/bios8010003 · Cited by 238
Soft Bioelectronics Based on Nanomaterials
Cho, K. W., Sunwoo, S.-H., Hong, Y. J., Koo, J. H., Kim, J. H., Baik, S., Hyeon, T., & Kim, D.-H. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00531 · Cited by 244
Recent advances and perspectives in sweat based wearable electrochemical sensors
Mohan, A. M. V., Rajendran, V., Mishra, R. K., & Jayaraman, M. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116024 · Cited by 231
A highly integrated sensing paper for wearable electrochemical sweat analysis
Li, M., Wang, L., Liu, R., Li, J., Zhang, Q., Shi, G., Li, Y., Hou, C., & Wang, H. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112828 · Cited by 218
Recent advancement in biosensors technology for animal and livestock health management
Neethirajan, S., Tuteja, S. K., Huang, S.-T., & Kelton, D. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.015 · Cited by 201
Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes
Guinovart, T., Parrilla, M., Crespo, G. A., Rius, F. X., & Andrade, F. J. (2013) · The Analyst · doi:10.1039/c3an00710c · Cited by 208
Materials and Wearable Devices for Autonomous Monitoring of Physiological Markers
Wu, W., & Haick, H. (2018) · Advanced Materials · doi:10.1002/adma.201705024 · Cited by 208
Wearable Biosensors for Non-Invasive Sweat Diagnostics
Xu, J., Fang, Y., & Chen, J. (2021) · Biosensors · doi:10.3390/bios11080245 · Cited by 208
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Vinoth, R., Nakagawa, T., Mathiyarasu, J., & Mohan, A. M. V. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02446 · Cited by 193
Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring
Hatamie, A., Angizi, S., Kumar, S., Pandey, C. M., Simchi, A., Willander, M., & Malhotra, B. D. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6827 · Cited by 184
Lu, T., Ji, S., Jin, W., Yang, Q., Luo, Q., & Ren, T.-L. (2023) · Sensors · doi:10.3390/s23062991 · Cited by 159
Wang, S., Wu, Y., Gu, Y., Li, T., Luo, H., Li, L.-H., Bai, Y., Li, L., Liu, L., Cao, Y., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01560 · Cited by 174
Carbon fiber based electrochemical sensor for sweat cortisol measurement
Sekar, M., Pandiaraj, M., Bhansali, S., Ponpandian, N., & Viswanathan, C. (2019) · Scientific Reports · doi:10.1038/s41598-018-37243-w · Cited by 161
A wearable conductivity sensor for wireless real-time sweat monitoring
Liu, G., Ho, C., Slappey, N., Zhou, Z., Snelgrove, S. E., Brown, M., Grabinski, A., Guo, X., Chen, Y., Miller, K., et al. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.12.034 · Cited by 158
Wearable Self‐Powered Electrochemical Devices for Continuous Health Management
Parrilla, M., & Wael, K. D. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202107042 · Cited by 163
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc01082j · Cited by 156
The role of sampling in wearable sweat sensors
Liu, C., Xu, T., Wang, D., & Zhang, X. (2020) · Talanta · doi:10.1016/j.talanta.2020.120801 · Cited by 151
Monitoring biomolecule concentrations in tissue using a wearable droplet microfluidic-based sensor
Nightingale, A. M., Leong, C. L., Burnish, R., Hassan, S.-U., Zhang, Y., Clough, G. F., Boutelle, M. G., Voegeli, D., & Niu, X. (2019) · Nature Communications · doi:10.1038/s41467-019-10401-y · Cited by 160
‘SWEATCH’: A Wearable Platform for Harvesting and Analysing Sweat Sodium Content
Glennon, T., O'Quigley, C., McCaul, M., Matzeu, G., Beirne, S., Wallace, G. G., Stroiescu, F., O'Mahoney, N., White, P., & Diamond, D. (2016) · Electroanalysis · doi:10.1002/elan.201600106 · Cited by 147
Self-citationWearable Potentiometric Sensors for Medical Applications
Cuartero, M., Parrilla, M., & Crespo, G. A. (2019) · Sensors · doi:10.3390/s19020363 · Cited by 160
“in 2010 and consisted of a sodium ISE of inner-filling solution type that was embedded in a belt with an absorbent patch for sweat collection [25].”
Han, W., He, H., Zhang, L., Dong, C., Zeng, H., Dai, Y., Xing, L., Zhang, Y., & Xue, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07990 · Cited by 149
Recent Progress in Wearable Biosensors: From Healthcare Monitoring to Sports Analytics
Ye, S., Feng, S., Huang, L. J., & Bian, S. (2020) · Biosensors · doi:10.3390/bios10120205 · Cited by 163
“Early developed wearable biosensors mainly focused on detecting a single parameter, such as sodium concentrations [64].”
BackgroundLegner, C., Kalwa, U., Patel, V., Chesmore, A., & Pandey, S. (2019) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.07.020 · Cited by 142
“Sodium Dehydration, Cystic fibrosis [2,16,21,38,43,44,45,57,58,65]”
Continuous monitoring of chemical signals in plants under stress
Coatsworth, P., Gonzalez‐Macia, L., Collins, A., Bozkurt, T. O., & Güder, F. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00443-0 · Cited by 155
Sasikala, A., Nguyen, N., & Sreejith, K. R. (2024) · Lab on a Chip · doi:10.1039/d4lc00089g · Cited by 152
Flexible planar concentric circular micro-supercapacitor arrays for wearable gas sensing application
Li, L., Fu, C., Lou, Z., Chen, S., Han, W., Jiang, K., Chen, D., & Shen, G. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.08.060 · Cited by 136
Zuliani, C., & Diamond, D. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.147 · Cited by 131
Self-citationCheong, Y. H., Ge, L., & Lisak, G. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338304 · Cited by 134
Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat
Parrilla, M., Ferré, J., Guinovart, T., & Andrade, F. J. (2016) · Electroanalysis · doi:10.1002/elan.201600070 · Cited by 122
Engineering Materials for Electrochemical Sweat Sensing
Wang, Z., Shin, J., Park, J., Lee, H., Kim, D., & Liu, H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202008130 · Cited by 145
Hybrid Integration of Wearable Devices for Physiological Monitoring
Zhang, Y., Zheng, X. T., Zhang, X., Pan, J., & Thean, A. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00471 · Cited by 137
Curto, V. F., Coyle, S. M., Byrne, R., Angelov, N., Diamond, D., & Benito‐Lopez, F. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.02.010 · Cited by 134
“[12] using a sodium sensor belt (SSB) based on Ion Selective Electrodes (ISE).”
MethodSelf-citationFlexible Sweat Sensors: From Films to Textiles
Luo, D., Sun, H., Li, Q., Niu, X., He, Y., & Liu, H. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02642 · Cited by 121
Embroidered electrochemical sensors for biomolecular detection
Liu, X., & Lillehoj, P. B. (2016) · Lab on a Chip · doi:10.1039/c6lc00307a · Cited by 110
System Architectures in Wearable Electrochemical Sensors
Steinberg, M. D., Kassal, P., & Steinberg, I. M. (2016) · Electroanalysis · doi:10.1002/elan.201600094 · Cited by 107
Yuan, Z., Hou, L., Bariya, M., Nyein, H. Y. Y., Tai, L., Ji, W., Li, L., & Javey, A. (2019) · Lab on a Chip · doi:10.1039/c9lc00598f · Cited by 105
Recent advances in flexible and wearable sensors for monitoring chemical molecules
Zhao, H., Su, R., Teng, L., Tian, Q., Han, F., Li, H., Cao, Z., Xie, R., Li, G., Liu, X., et al. (2021) · Nanoscale · doi:10.1039/d1nr06244a · Cited by 105
Access and Management of Sweat for Non‐Invasive Biomarker Monitoring: A Comprehensive Review
Saha, T., Caño, R. D., la Paz, E. D., Sandhu, S. S., & Wang, J. (2022) · Small · doi:10.1002/smll.202206064 · Cited by 105
Wearable Sweat Sensors: Background and Current Trends
Kaya, T., Liu, G., Ho, J., Yelamarthi, K., Miller, K., Edwards, J., & Stannard, A. (2019) · Electroanalysis · doi:10.1002/elan.201800677 · Cited by 99
A 3D Printed Wearable Bioelectronic Patch for Multi‐Sensing and In Situ Sweat Electrolyte Monitoring
Kim, T., Qian, Y. H., Hoang, E., & Esfandyarpour, R. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202001021 · Cited by 106
KickStat: A Coin-Sized Potentiostat for High-Resolution Electrochemical Analysis
Hoilett, O. S., Walker, J., Balash, B. M., Jaras, N. J., Boppana, S., & Linnes, J. C. (2020) · Sensors · doi:10.3390/s20082407 · Cited by 95
Comparison of Colorimetric Analyses to Determine Cortisol in Human Sweat
Tu, E., Pearlmutter, P., Tiangco, M., Derose, G., Begdache, L., & Koh, A. (2020) · ACS Omega · doi:10.1021/acsomega.0c00498 · Cited by 90
Criscuolo, F., Taurino, I., Stradolini, F., Carrara, S., & Micheli, G. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.062 · Cited by 91
Clark, K. M., & Ray, T. R. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01512 · Cited by 93
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86
Assalve, G., Lunetti, P., di Cagno, A., Luca, E. W. D., Aldegheri, S., Zara, V., & Ferramosca, A. (2024) · Biosensors · doi:10.3390/bios14120574 · Cited by 99
Huang, Y., Wang, T., Xu, Z., Hughes, E., Qian, F., Lee, M., Fan, Y., Lei, Y., Brückner, C., & Li, B. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b05928 · Cited by 86
Niu, J., Lin, S., Chen, D., Wang, Z., Cao, C., Gao, A., Cui, S., Liu, Y., Hong, Y., Zhi, X., et al. (2023) · Small · doi:10.1002/smll.202306769 · Cited by 84
Physiological stress monitoring using sodium ion potentiometric microsensors for sweat analysis
Cazalé, A., Sant, W., Ginot, F., Launay, J., Savourey, G., Revol-Cavalier, F., Lagarde, J., Heinry, D., Launay, J., & Temple‐Boyer, P. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.10.114 · Cited by 84
“Consequently, a wearable sensing system was developed, integrating a textile-based fluid handling system for sweat collection and transport as well as conductivity, pH and pNa sensors [44,45].”
MethodBandodkar, A. J., O'Mahony, A. M., Ramírez, J., Samek, I. A., Anderson, S. M., Windmiller, J. R., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01179h · Cited by 79
Next-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies
Fathy, M. A., & Bühlmann, P. (2025) · Biosensors · doi:10.3390/bios15010051 · Cited by 86
Toward wearable patch for sweat analysis
Dam, V. A. T., Zevenbergen, M. A. G., & van Schaijk, R. T. F. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.143 · Cited by 87
Development of a wearable electrochemical sensor for voltammetric determination of chloride ions
Bujes-Garrido, J., & Arcos‐Martínez, M. J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.08.119 · Cited by 79
Maity, K., Garain, S., Henkel, K., Schmeißer, D., & Mandal, D. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b15320 · Cited by 78
Wearable microfluidic-based e-skin sweat sensors
Tabasum, H., Gill, N. K., Mishra, R., & Lone, S. (2022) · RSC Advances · doi:10.1039/d1ra07888g · Cited by 80
Niiyama, A., Murata, K., Shigemori, Y., Zebda, A., & Tsujimura, S. (2019) · Journal of Power Sources · doi:10.1016/j.jpowsour.2019.04.064 · Cited by 73
Skin-Mountable Biosensors and Therapeutics: A Review
Lee, E. K., Kim, M. K., & Lee, C. H. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052315 · Cited by 75
Liquid‐Gated Transistors Based on Reduced Graphene Oxide for Flexible and Wearable Electronics
de Oliveira, R. F., Livio, P. A., Montes‐García, V., Ippolito, S., Eredia, M., Fanjul‐Bolado, P., García, M. B. G., Casalini, S., & Samorí, P. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201905375 · Cited by 87
Metadata
- Authors
- Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D.
- Affiliations
- Dublin Institute of Technology (IE)
- Dublin City University (IE)
- Corresponding author
- Schazmann, Benjamin
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 2
- Issue
- 4
- Pages
- 342
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W2144506268
- Cited by
- 286
- References
- 43
- Citations by year
- 2026: 13 · 2025: 20 · 2024: 23 · 2023: 28 · 2022: 18 · 2021: 28 · 2020: 27 · 2019: 29 · 2018: 20 · 2017: 25 · 2016: 18 · 2015: 13 · 2014: 12 · 2013: 7 · 2012: 3
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- green
- orcid.org
- Locations
- Analytical Methods (publishedVersion)
- Dublin City University Open Access Institutional Repository (Dublin City University) (submittedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- Arrow@dit (Dublin Institute of Technology) (submittedVersion)
- Arrow@dit (Dublin Institute of Technology) (submittedVersion, cc-by-nc-sa)
- Arrow - TU Dublin (Technological University Dublin) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- sweat sodium concentration, wearable electrochemical sensors, ion-selective electrodes, real-time physiological monitoring, cystic fibrosis, exercise physiology, sweat collection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.