Upper limb prosthesis use and abandonment: A survey of the last 25 years
The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
This review presents an analytical and comparative survey of upper limb prosthesis acceptance and abandonment as documented over the past 25 years, detailing areas of consumer dissatisfaction and ongoing technological advancements. English-language articles were identified in a search of Ovid, PubMed, and ISI Web of Science (1980 until February 2006) for key words upper limb and prosthesis. Articles focused on upper limb prostheses and addressing: (i) Factors associated with abandonment; (ii) Rejection rates; (iii) Functional analyses and patterns of wear; and (iv) Consumer satisfaction, were extracted with the exclusion of those detailing tools for outcome measurement, case studies, and medical procedures. Approximately 200 articles were included in the review process with 40 providing rates of prosthesis rejection. Quantitative measures of population characteristics, study methodology, and prostheses in use were extracted from each article. Mean rejection rates of 45% and 35% were observed in the literature for body-powered and electric prostheses respectively in pediatric populations. Significantly lower rates of rejection for both body-powered (26%) and electric (23%) devices were observed in adult populations while the average incidence of non-wear was similar for pediatric (16%) and adult (20%) populations. Documented rates of rejection exhibit a wide range of variance, possibly due to the heterogeneous samples involved and methodological differences between studies. Future research should comprise of controlled, multifactor studies adopting standardized outcome measures in order to promote comprehensive understanding of the factors affecting prosthesis use and abandonment. An enhanced understanding of these factors is needed to optimize prescription practices, guide design efforts, and satiate demand for evidence-based measures of intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osseointegration in skeletal reconstruction and rehabilitation: a review.
Brånemark, R., Brånemark, P., Rydevik, B. L., & Myers, R. R. (2001) · PubMed · Cited by 840
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583 · cited 2×
“…implantable myoelectric sensors (Weir et al. 2005), reinnervation strategies for increased control sites and simultaneous coordination of joints (Kuiken et al. 2004), and osseointegration (Hagberg et al. 2005; Branemark et al. 2001), may pave the way for a new generation of more functional,…”
BackgroundDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415 · cited 1×
“Initiatives to improve control strategies, (Chan and Englehart 2003; Nishikawa et al. 2000; Ajiboye and Weir 2005, Huang et al. 2005; Khadivi et al. 2005; Sibelius et al. 2005a, 2005b), to exploit mechanomyography as a means of circumventing problems of perspiration and electrode placement (Silva…”
BackgroundMultiple finger, passive adaptive grasp prosthetic hand
Dechev, N., Cleghorn, W. L., & Naumann, S. (2001) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(01)00035-0 · Cited by 304
Prosthetic usage in major upper extremity amputations
Wright, T. W., Hagen, A. D., & Wood, M. B. (1995) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80278-3 · Cited by 266
The SPRING Hand: Development of a Self-Adaptive Prosthesis for Restoring Natural Grasping
Carrozza, M. C., Suppo, C., Sebastiani, F., Massa, B., Vecchi, F., Lazzarini, R., Cutkosky, M. R., & Dario, P. (2004) · Autonomous Robots · doi:10.1023/b:auro.0000016863.48502.98 · Cited by 255
Davidson, J. (2002) · Journal of Hand Therapy · doi:10.1016/s0894-1130(02)50011-9 · Cited by 206
Research works printed but not linked: 20
- Dalsey, 1989, Myoelectric prosthetic replacement in the upper-extremity amputee, Orthop Rev, 18, 697
- Del Cura, 2003, Study of the different types of actuators and mechanisms for upper limb prostheses, Artif Organs, 27, 506
- dos Santos, 2003, The application of shape memory actuators in anthropomorphic upper limb prostheses, Artif Organs, 27, 473, 10.1046/j.1525-1594.2003.07242.x · doi:10.1046/j.1525-1594.2003.07242.x
- Durance, 1988, Upper limb amputees: A clinic profile, Int Disabil Stud, 10, 68, 10.3109/09638288809164107 · doi:10.3109/09638288809164107
- Hacking, 1997, Long-term outcome of upper limb prosthetic use in the Netherlands, Eur J Phys Med Rehabil, 7, 179
- Hermansson, 2005, Psychosocial adjustment in Swedish children with upper-limb reduction deficiency and a myoelectric prosthetic hand, Acta Paediatr, 94, 479, 10.1080/08035250410022512 · doi:10.1080/08035250410022512
- Ivko, 1999, Independence through humeral rotation in the conventional transhumeral prosthetic design, J Prosthet Orthot, 11, 20, 10.1097/00008526-199901110-00006 · doi:10.1097/00008526-199901110-00006
- LeBlanc, 1988, Use of prosthetic prehensors, Prosthet Orthot Int, 12, 152, 10.3109/03093648809079399 · doi:10.3109/03093648809079399
- Leow, 2001, Esthetic prostheses in minor and major upper limb amputations, Hand Clin, 17, 489, 10.1016/S0749-0712(21)00527-8 · doi:10.1016/s0749-0712(21)00527-8
- Melendez, 1988, Survey of arm amputees not wearing prostheses: Implications for research and service, J Assoc Child Prosthet Orthot Clin, 23, 62
- Menkveld, 1987, Age-appropriateness of myoelectric prosthetic fitting, J Assoc Child Prosthet Orthot Clin, 22, 60
- Pinzur, 1994, Functional outcome following traumatic upper limb amputation and prosthetic limb fitting, J Hand Surg, 19A, 836, 10.1016/0363-5023(94)90197-X · doi:10.1016/0363-5023(94)90197-x
- Pons, 2002, High torque ultrasonic motors for hand prosthetics: Current status and trends, Technol Heath Care, 10, 2
- Pruitt, 1997, Prosthesis satisfaction outcome measurement in pediatric limb deficiency, Arch Phys Med Rehabil, 78, 750, 10.1016/S0003-9993(97)90084-8 · DOI
- Reid, 1987, Survey of juvenile hand amputees, J Assoc Child Prosthet Orthot Clin, 22, 51
- Scotland, 1983, A long-term review of children with congenital and acquired upper limb deficiency, J Bone Joint Surg, 65B, 346, 10.1302/0301-620X.65B3.6841409 · doi:10.1302/0301-620x.65b3.6841409
- Shaperman, 2003, Early upper limb prosthesis fitting: When and what do we fit?, J Prosthet Orthot, 15, 11, 10.1097/00008526-200301000-00004 · doi:10.1097/00008526-200301000-00004
- Trost, 1983, A comparison of conventional and myoelectric below-elbow prosthetic use, ICIB, 18, 9
- Weaver, 1988, Comparison of myoelectric and conventional prostheses for adolescent amputees, Am J Occup Ther, 42, 87, 10.5014/ajot.42.2.87 · doi:10.5014/ajot.42.2.87
- Yang, 2004, A multi-fingered hand prosthesis, Mech Mach Theory, 39, 555, 10.1016/j.mechmachtheory.2004.01.002 · doi:10.1016/j.mechmachtheory.2004.01.002
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
Upper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645
Self-citationSoft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Self-citationControl of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
3D-printed upper limb prostheses: a review
ten Kate, J., Smit, G., & Breedveld, P. (2017) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483107.2016.1253117 · Cited by 374
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Advanced Upper Limb Prosthetic Devices: Implications for Upper Limb Prosthetic Rehabilitation
Resnik, L., Meucci, M. R., Lieberman-Klinger, S., Fantini, C., Kelty, D. L., Disla, R., & Sasson, N. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.11.010 · Cited by 280
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Salminger, S., Stino, H., Pichler, L. H., Gstoettner, C., Sturma, A., Mayer, J. A., Szivak, M., & Aszmann, O. C. (2022) · Disability and Rehabilitation · doi:10.1080/09638288.2020.1866684 · Cited by 260
The Hannes hand prosthesis replicates the key biological properties of the human hand
Laffranchi, M., Boccardo, N., Traverso, S., Lombardi, L., Canepa, M., Lince, A., Semprini, M., Saglia, J. A., Naceri, A., Sacchetti, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.abb0467 · Cited by 252
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2177662 · Cited by 251
“alone, almost 80% of whom choose to use a prosthesis on a daily basis [1].”
BackgroundHaptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“at all due to a lack of tactile sensory feedback [23–26].”
BackgroundProsthesis rejection in acquired major upper-limb amputees: a population-based survey
Østlie, K., Lesjø, I. M., Franklin, R. J., Garfelt, B., Skjeldal, O. H., & Magnus, P. (2012) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2011.635405 · Cited by 241
“Also, the rejection rates for passive, myoelectric and body-powered prostheses vary considerably in the literature and it is difficult to make comparisons between the wear patterns of passive and active devices, as one type often supplements the other, and the use of multiple prostheses is widely recommended [7].”
BackgroundResultInfluentialDifferences in myoelectric and body-powered upper-limb prostheses: systematic literature review
Carey, S. L., Lura, D. J., Highsmith, M. J., CP, & FAAOP (2015) · Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.08.0192 · Cited by 227
Graczyk, E. L., Resnik, L., Schiefer, M. A., Schmitt, M. S., & Tyler, D. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-26952-x · Cited by 216
D’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-11306-w · Cited by 215
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Prosthetic hand rejection rates are estimated to be as high as 40% [3], with some of user’s reasons for rejection and not wearing a prosthetic device being that they believe it is more functional and easier to receive sensory feedback through their stump without using the prosthetic hand [4].”
BackgroundClemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209
Pasquina, P. F., Evangelista, M., Carvalho, A. J., Lockhart, J., Griffin, S., Nanos, G., McKay, P., Hansen, M., Ipsen, D., Vandersea, J., et al. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.016 · Cited by 205
Smail, L. C., Neal, C., Wilkins, C., & Packham, T. L. (2021) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483107.2020.1738567 · Cited by 198
A review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192
Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
“amputees, and one of the reasons such devices are abandoned.(6,7,23) Moreover, the quality of the elicited sensations was little differentiated (mostly paresthesia was reported(15)).”
BackgroundSamuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
“While several amputees have benefitted from the nonpattern recognition-based prostheses control system, they have also been denied of the intuitiveness and dexterity associated with the natural hand functions, which may lead to secondary prostheses rejection [9].”
BackgroundNew developments in prosthetic arm systems
Vujaklija, I., Farina, D., & Aszmann, O. (2016) · Orthopedic Research and Reviews · doi:10.2147/orr.s71468 · Cited by 185
“32 After the development of the Otto Bock Muenster style socket in the 1960s 33 and the Northwestern University socket in 1972, 34 the transradial powered prosthesis socket design has not significantly changed.”
MethodA practical 3D-printed soft robotic prosthetic hand with multi-articulating capabilities
Mohammadi, A., Lavranos, J., Zhou, H., Mutlu, R., Alici, G., Tan, Y., Choong, P., & Oetomo, D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0232766 · Cited by 184
Furui, A., Eto, S., Nakagaki, K., Shimada, K., Nakamura, G., Masuda, A., Chin, T., & Tsuji, T. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6339 · Cited by 183
Implementation of 3D Printing Technology in the Field of Prosthetics: Past, Present, and Future
Manero, A., Smith, P., Sparkman, J., Dombrowski, M., Courbin, D., Kester, A., Womack, I., & Chi, A. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16091641 · Cited by 181
“Multiple studies have found that feedback is crucial in improving control of a myoelectric prosthesis [33,44].”
BackgroundSurveying the interest of individuals with upper limb loss in novel prosthetic control techniques
Engdahl, S. M., Christie, B. P., Kelly, B., Davis, A., Chestek, C. A., & Gates, D. H. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0044-2 · Cited by 179
“Mean estimates of prosthesis rejection rates are 26 % for bodypowered prostheses and 23 % for electric prostheses [3].”
BackgroundPage, D. M., George, J. A., Kluger, D. T., Duncan, C., Wendelken, S., Davis, T., Hutchinson, D. T., & Clark, G. A. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00352 · Cited by 175
Resnik, L., Huang, H. (., Winslow, A., Crouch, D. L., Zhang, F., & Wolk, N. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0361-3 · Cited by 174
Osseointegration amputation prostheses on the upper limbs: methods, prosthetics and rehabilitation
Jönsson, S., Caine-Winterberger, K., & Brånemark, R. (2011) · Prosthetics & Orthotics International · doi:10.1177/0309364611409003 · Cited by 170
Naik, G. R., Al-Timemy, A. H., & Nguyen, H. T. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2478138 · Cited by 160
“For these people, the replacement of missing arm functionalities can be of a significant improvement to the quality of life [5]–[7].”
BackgroundAszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61776-1 · Cited by 152
Development of an Implantable Myoelectric Sensor for Advanced Prosthesis Control
Merrill, D. R., Lockhart, J., Troyk, P. R., Weir, R. F., & Hankin, D. L. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01219.x · Cited by 117
“About 80% use a prosthesis (4), of which 50% are myoelectric-controlled (5) and 50% are body-powered and controlled.”
BackgroundForearm amputees' views of prosthesis use and sensory feedback
Wijk, U., & Carlsson, I. (2015) · Journal of Hand Therapy · doi:10.1016/j.jht.2015.01.013 · Cited by 114
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Technological Advances in Prosthesis Design and Rehabilitation Following Upper Extremity Limb Loss
Bates, T. J., Fergason, J. R., & Pierrie, S. N. (2020) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-020-09656-6 · Cited by 95
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics
Rijnbeek, E. H., Eleveld, N., & Olthuis, W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00350 · Cited by 91
“The lack of sensory feedback emphasizes the need for high-quality recording and stimulation electrodes to more natural control of the prosthesis (Biddiss and Chau, 2007).”
BackgroundIrwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046007 · Cited by 78
“this state-of-the-art technology is not significantly better than that of simple body-powered hooks [1, 5].”
BackgroundFrost, C. M., Ursu, D. C., Flattery, S. M., Nedic, A., Hassett, C. A., Moon, J. D., Buchanan, P. J., Brent Gillespie, R., Kung, T. A., Kemp, S. W. P., et al. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0452-1 · Cited by 68
An Analysis of Usability Evaluation Practices and Contexts of Use in Wearable Robotics
Meyer, J. T., Gassert, R., & Lambercy, O. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00963-8 · Cited by 58
Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2747899 · Cited by 57
“During the past decade, multiple sophisticated powered prosthetic hands have become available in the market, yet the rejection rate for electric upper-limb prostheses is roughly 30% [1] due to dissatisfaction about issues like cosmetics, comfort, function, ease of control, reliability, and cost [4].”
BackgroundSensory- and Action-Oriented Embodiment of Neurally-Interfaced Robotic Hand Prostheses
Di Pino, G., Romano, D., Spaccasassi, C., Mioli, A., D’Alonzo, M., Sacchetti, R., Guglielmelli, E., Zollo, L., Di Lazzaro, V., Denaro, V., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00389 · Cited by 52
“Today, commercial hand prostheses do not offer sensory feedback, although position and force information from the prosthesis are identified as design priority for myoelectric devices, in order to increase acceptance (Biddiss and Chau, 2007).”
BackgroundIn vivo characterization of regenerative peripheral nerve interface function
Ursu, D. C., Urbanchek, M. G., Nedic, A., Cederna, P. S., & Gillespie, R. B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026012 · Cited by 46
Fascicular nerve stimulation and recording using a novel double-aisle regenerative electrode
Delgado-Martínez, I., Righi, M., Santos, D., Cutrone, A., Bossi, S., D’Amico, S., Del Valle, J., Micera, S., & Navarro, X. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6bac · Cited by 35
Fani, S., Bianchi, M., Jain, S., Pimenta Neto, J. S., Boege, S., Grioli, G., Bicchi, A., & Santello, M. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00011 · Cited by 31
Jiralerspong, T., Nakanishi, E., Liu, C., & Ishikawa, J. (2017) · Applied Sciences · doi:10.3390/app7111163 · Cited by 30
Stephens-Fripp, B., Sencadas, V., Mutlu, R., & Alici, G. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00179 · Cited by 29
Plasticity in the Visual System is Associated with Prosthesis Use in Phantom Limb Pain
Preißler, S., Dietrich, C., Blume, K. R., Hofmann, G. O., Miltner, W. H. R., & Weiss, T. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00311 · Cited by 29
“Using a prosthesis requires permanent visual guidance (Atkins et al., 1996; Biddiss and Chau, 2007).”
BackgroundČvančara, P., Valle, G., Müller, M., Guiho, T., Hiairrassary, A., Petrini, F., Raspopovic, S., Strauss, I., Granata, G., Fernandez, E., et al. (2019) · doi:10.1101/653964 · Cited by 12
Is the Prosthetic Homologue Necessary for Embodiment?
Dornfeld, C., Swanston, M., Cassella, J., Beasley, C., Green, J., Moshayev, Y., & Wininger, M. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00021 · Cited by 6
Metadata
- Authors
- Biddiss, E. A., & Chau, T. T.
- Venue
- Prosthetics & Orthotics International
- Published
- 2007-09
- Volume
- 31
- Issue
- 3
- Pages
- 236-257
- ISSN
- 0309-3646 (ISSN-L)
- OpenAlex
- W2132855977
- Cited by
- 1,111
- References
- 62
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.