Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
The DOI matches its Crossref record.
Abstract
More than 6,600 one-page surveys were sent to individuals throughout the country with upper-limb loss or absence. Of those surveys, 2,477 were returned, and demographic information was recorded. A more comprehensive seven-page survey was then sent to the respondents who agreed to participate. A total of 1,575 of these surveys were returned: 1,020 by body-powered users, 438 by electric users and 117 by bilateral users of prostheses. The results of the surveys indicate users of body-powered and electric prostheses identify surprisingly similar elements as necessary in the design of a better upper-limb prosthesis. These qualities include additional wrist movement, better control mechanisms that require less visual attention and the ability to make coordinated motions of two joints. Desired near-term improvements for body-powered prostheses include better cables and harness comfort, whereas those for electric prostheses include better gloving material, better batteries and charging units, and improved reliability for the hand and its electrodes. This article discusses the specific functions that various levels of upper-extremity amputees gain from their prostheses as well as the device features that aid or detract from their functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
“The possibility of adding physiologically appropriate touch sensations to hand prosthesis could enhance the controllability and, thus, acceptability (6, 7) of such a device, bringing it closer to the natural manipulation strategy.”
BackgroundFarina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716
Upper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
“Lastly, insights provided through qualitative comments and reflections have yet to be expressly used in the definition of consumer priorities [6].”
BackgroundResultInfluentialMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
Design of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341
Design and development of an underactuated prosthetic hand
Massa, B., Roccella, S., Carrozza, M. C., & Dario, P. (2003) · Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) · doi:10.1109/robot.2002.1014232 · Cited by 333
The 2017 IEEE International Conference on Fuzzy Systems
(2016) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2016.2545826 · Cited by 308
Xu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504155 · Cited by 304
Multiple finger, passive adaptive grasp prosthetic hand
Dechev, N., Cleghorn, W. L., & Naumann, S. (2001) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(01)00035-0 · Cited by 304
Characterization of a Benchmark Database for Myoelectric Movement Classification
Atzori, M., Gijsberts, A., Kuzborskij, I., Elsig, S., Mittaz Hager, A.-G., Deriaz, O., Castellini, C., Muller, H., & Caputo, B. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328495 · Cited by 293
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Advanced Upper Limb Prosthetic Devices: Implications for Upper Limb Prosthetic Rehabilitation
Resnik, L., Meucci, M. R., Lieberman-Klinger, S., Fantini, C., Kelty, D. L., Disla, R., & Sasson, N. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.11.010 · Cited by 280
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005942 · Cited by 266
Building the Ninapro database: A resource for the biorobotics community
Atzori, M., Gijsberts, A., Heynen, S., Hager, A.-G. M., Deriaz, O., van der Smagt, P., Castellini, C., Caputo, B., & Muller, H. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290287 · Cited by 262
Salminger, S., Stino, H., Pichler, L. H., Gstoettner, C., Sturma, A., Mayer, J. A., Szivak, M., & Aszmann, O. C. (2022) · Disability and Rehabilitation · doi:10.1080/09638288.2020.1866684 · Cited by 260
Results of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257
“…pylatiuk@iai.fzk.de ISSN 0309-3646 print/ISSN 1746-1553 online 2007 ISPO DOI: 10.1080/03093640601061265 Kejlaa 1993) or questionnaires were sent to potential users (Atkins et al. 1996, Burger and Marin cek 1994; Kyberd et al. 1998; Datta et al. 2004; Fraser 1993; Roeschlein and Domholdt 1989).”
BackgroundMethodResultInfluentialSchiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
“This lack of sensation and reliance on alternative sensory input is one of the primary complaints associated with myoelectric prostheses [10, 11].”
BackgroundThe SPRING Hand: Development of a Self-Adaptive Prosthesis for Restoring Natural Grasping
Carrozza, M. C., Suppo, C., Sebastiani, F., Massa, B., Vecchi, F., Lazzarini, R., Cutkosky, M. R., & Dario, P. (2004) · Autonomous Robots · doi:10.1023/b:auro.0000016863.48502.98 · Cited by 255
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“Haptics for total impairment aims to restore missing tactile or proprioceptive information vital to prosthetic grasp to prolong sustained prosthesis use [28–31].”
BackgroundDifferences in myoelectric and body-powered upper-limb prostheses: systematic literature review
Carey, S. L., Lura, D. J., Highsmith, M. J., CP, & FAAOP (2015) · Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.08.0192 · Cited by 227
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287383 · Cited by 218
“In general, the clinical and commercial impact of myoelectric controlled prostheses remains very limited: only one out of four upper limb amputees uses this kind of prosthesis on a daily basis, even when the related costs are reimbursed [4].”
BackgroundD’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-11306-w · Cited by 215
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
“A survey completed in 1996 identified control of more DOFs is the greatest desire for below-elbow amputees [ 12 ].”
BackgroundA Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Prosthetic users have also shown a strong desire to decrease the need for visual attention to perform functions [2].”
BackgroundPasquina, P. F., Evangelista, M., Carvalho, A. J., Lockhart, J., Griffin, S., Nanos, G., McKay, P., Hansen, M., Ipsen, D., Vandersea, J., et al. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.016 · Cited by 205
Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation
Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2033113 · Cited by 204
Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
“amputees, and one of the reasons such devices are abandoned.(6,7,23) Moreover, the quality of the elicited sensations was little differentiated (mostly paresthesia was reported(15)).”
BackgroundHorch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194
“There are a number of shortcomings with these systems, including limited or no prehension feedback and control limited to one movement at a time [1].”
BackgroundHargrove, L. J., Miller, L. A., Turner, K., & Kuiken, T. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-14386-w · Cited by 190
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
“In 1996, The Institute for Rehabilitation and Research published the results of a survey of the top research priorities of more than 2,000 upper limb amputees [6].”
BackgroundDhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
“Upper limb amputees strongly desire a prosthetic control system that provides prehension feedback from the terminal device (Atkins et al. 1996).”
BackgroundImplementation of 3D Printing Technology in the Field of Prosthetics: Past, Present, and Future
Manero, A., Smith, P., Sparkman, J., Dombrowski, M., Courbin, D., Kester, A., Womack, I., & Chi, A. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16091641 · Cited by 181
“Medical advancements since the invention of the Hanger Limb have significantly reduced limb loss due to traumatic events [4,5].”
BackgroundSensory feedback prosthesis reduces phantom limb pain: Proof of a principle
Dietrich, C., Walter-Walsh, K., Preißler, S., Hofmann, G. O., Witte, O. W., Miltner, W. H. R., & Weiss, T. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2011.10.068 · Cited by 180
“The study results underline the principle that a myoelectric prosthesis providing sensory feedback about grip strength might be advantageous [29,30,39] in terms of achieving better operative control with less visual guidance [1].”
Muceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172
“open–close, they are the most desired and functionally important missing functions in commercial prostheses for transradial amputees [17].”
BackgroundMechanisms of the Anatomically Correct Testbed Hand
Deshpande, A. D., Xu, Z., Weghe, M. J. V., Brown, B. H., Ko, J., Chang, L. Y., Wilkinson, D. D., Bidic, S. M., & Matsuoka, Y. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2166801 · Cited by 170
“the upper extremity amputees do not use their prosthetic hand regularly because of reduced functionality, poor cosmetic appearance, and limited controllability [3], [16], [60].”
BackgroundVibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150
Behavioral Demonstration of a Somatosensory Neuroprosthesis
Berg, J. A., Dammann, J. F., Tenore, F. V., Tabot, G. A., Boback, J. L., Manfredi, L. R., Peterson, M. L., Katyal, K. D., Johannes, M. S., Makhlin, A., et al. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2244616 · Cited by 119
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
An sEMG-Based Human–Robot Interface for Robotic Hands Using Machine Learning and Synergies
Meattini, R., Benatti, S., Scarcia, U., De Gregorio, D., Benini, L., & Melchiorri, C. (2018) · IEEE Transactions on Components, Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2018.2799987 · Cited by 115
Forearm amputees' views of prosthesis use and sensory feedback
Wijk, U., & Carlsson, I. (2015) · Journal of Hand Therapy · doi:10.1016/j.jht.2015.01.013 · Cited by 114
Jia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70
Stephens-Fripp, B., Sencadas, V., Mutlu, R., & Alici, G. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00179 · Cited by 29
“Prosthetic users have also shown a desire to incorporate sensory feedback to reduce their reliance on visual information (Atkins et al., 1996), as sight alone does not provide sufficient information for effective control (Johansson and Flanagan, 2009) and increases the congitive load on the amputee.”
BackgroundPlasticity in the Visual System is Associated with Prosthesis Use in Phantom Limb Pain
Preißler, S., Dietrich, C., Blume, K. R., Hofmann, G. O., Miltner, W. H. R., & Weiss, T. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00311 · Cited by 29
“A former national survey of 1,575 amputees addressed the lack of sensory feedback and the increased requirement of visual control by requesting“better control mechanisms that require less visual attention” (Atkins et al., 1996).”
BackgroundLukyanenko, P., Dewald, H. A., Lambrecht, J., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00833-3 · Cited by 27
“The man–machine interface, limited in both feed-forward control and closed-loop control, is a major contributor to abandonment [2, 3].”
BackgroundMarasco, P. D., & Kuiken, T. A. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.4044-10.2010 · Cited by 19
“There is a strong desire on the part of upper limb amputees to have prosthetic devices that provide sensory feedback (Atkins et al., 1996; Biddiss et al., 2007), yet current prostheses lack this feature (Scott, 1990).”
On the development of optical peripheral nerve interfaces
Anderson, H., & Weir, R. F. (2019) · Neural Regeneration Research · doi:10.4103/1673-5374.245461 · Cited by 14
“When asked what changes prosthesis users would like to see, and may bring them back to prosthesis use, they have suggested things like improved dexterity, independent movement of fingers, sensory feedback, addition of fine motor skills, intuitive control, reliable precision, and additional degrees of freedom (Atkins e…”
Background
Metadata
- Authors
- Atkins, D. J., Heard, D. C. Y., & Donovan, W. H.
- Venue
- JPO Journal of Prosthetics and Orthotics
- Published
- 1996
- Volume
- 8
- Issue
- 1
- Pages
- 2-11
- ISSN
- 1040-8800 (ISSN-L)
- OpenAlex
- W2080716911
- Cited by
- 508
- References
- 0
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.