Accurate Power Loss Model Derivation of a High-Current Dual Active Bridge Converter for an Automotive Application
The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
Abstract
An accurate power loss model for a high-efficiency dual active bridge converter, which provides a bidirectional electrical interface between a 12-V battery and a high-voltage (HV) dc bus in a fuel cell car, is derived. The nominal power is 2 kW, the HV dc bus varies between 240 and 450 V, and the battery voltage range is between 11 and 16 V. Consequently, battery currents of up to 200 A occur at nominal power. In automotive applications, high converter efficiency and high power densities are required. Thus, it is necessary to accurately predict the dissipated power for each power component in order to identify and to properly design the heavily loaded parts of the converter. In combination with measured efficiency values, it is shown that conventional converter analysis predicts substantially inaccurate efficiencies for the given converter. This paper describes the main reasons why the conventional method fails and documents the different steps required to predict the power losses more accurately. With the presented converter prototype, an efficiency of more than 92% is achieved at an output power of 2 kW in a wide input/output voltage range.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535 · cited 1×
“Optimized modulation methods [12] or circuit variants—such as the three phase DAB [13]—enable a more effective converter utilization in order to reduce circulating currents and to obtain”
BackgroundEmadi, A., Lee, Y. J., & Rajashekara, K. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.922768 · Cited by 1,461 · cited 2×
“architecture, the electric power demand exceeds 10 kW [1], and”
BackgroundBai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121 · cited 1×
“currents and switching losses are reduced [12], [24].”
BackgroundEnergy Storage Systems for Automotive Applications
Lukic, S. M., Cao, J., Bansal, R. C., Rodriguez, F., & Emadi, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918390 · Cited by 1,025 · cited 1×
“and ultracapacitors for high peak power [2], provide the electric power.”
BackgroundEmadi, A., Williamson, S. S., & Khaligh, A. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.872378 · Cited by 714 · cited 1×
“Currently, the electric system in a conventional car consists of a 14-V dc power system architecture that comprises of a 12-V battery, starter motor, battery charger, and all the vehicular loads such as lighting and radio [4].”
BackgroundCalculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. A. A. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936396 · Cited by 704
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889939 · Cited by 669 · cited 1×
“On the assumption of negligible conduction losses and a negligible transformer magnetizing current (which is sufficiently fulfilled for higher power levels), these considerations lead to the most simple lossless electrical DAB model [Fig. 2(b)] [ 19 ].”
Optimal choice for number of strands in a litz-wire transformer winding
Sullivan, C. R. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.750181 · Cited by 558
Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.806023 · Cited by 409 · cited 2×
“, the modified Steinmetz equation [20], finite element analysis or the use of measurement results [21], is required.”
BackgroundMethodZhu, L. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.869730 · Cited by 381 · cited 1×
“Among the most prominent converter candidates are the isolated boost, full bridge converter [10], and the L-type (or current doubler) converter [11] due to their suitability for high-frequency operation and due to the similarities to the well-known buck and boost converters.”
Background
Research works printed but not linked: 1
- laeuffer, 2001, automotive requirements for power electronic converters in traction advanced control systems, Proc Int Intell Motion Conf, 207
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
“A power loss model of LV and high-current DAB-IBDC for automotive applications was analyzed in [98].”
MethodEfficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Self-citationClosed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635
“This DAB is realized for an automotive application and enables bidirectional power transfer between the HV power train and the LV dc bus (LV battery, LV ancillary loads) of a fuel cell car [1], [4].”
BackgroundSelf-citationGeneralized Average Modeling of Dual Active Bridge DC–DC Converter
Qin, H., & Kimball, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2165734 · Cited by 557
“It is an isolated, bidirectional, buck and boost dc–dc converter topology, which can be used in high-power applications for solid-state transformers [2], [3], smart grids [4], electric/hybrid vehicles [5], as well as interface among three dc ports [6].”
BackgroundHou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
“Then, based on different power-loss elements [18], [60], the corresponding power-loss model can be obtained.”
BackgroundMethodInfluentialImproved Core-Loss Calculation for Magnetic Components Employed in Power Electronic Systems
Muhlethaler, J., Biela, J., Kolar, J. W., & Ecklebe, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2162252 · Cited by 535
Self-citationOggier, G. G., Garcia, G. O., & Oliva, A. R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2072966 · Cited by 498
“The DAB topology using the conventional modulation strategy (CMS) can operate under soft switching, thus minimizing the power semiconductor switching losses, but only within a reduced range of operation, depending on the voltage conversion ratio and on the output current [4], [14], [15].”
BackgroundMethodTan, N. M. L., Abe, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2108317 · Cited by 490
“The advantages of the converter have made it attractive for high-power automotive applications [7]–[9] and utility applications [10]–[12].”
BackgroundTong, A., Hang, L., Li, G., Jiang, X., & Gao, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2692276 · Cited by 455
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
“switches [41].”
Minimum-Current-Stress Scheme of Dual Active Bridge DC-DC Converter With Unified-phase-shift Control
Hou, N., Song, W., & wu, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2521410 · Cited by 369
“However, the realization processes of efficiency-optimized switching strategies [11], [26], [27] are inconvenient and complicated in real-time”
BackgroundMethodRodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352
Zhao, B., Song, Q., & Liu, W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210563 · Cited by 325
“In [21]–[23], the authors studied the solutions to decrease power losses and increase efficiency of IBDC, but these studies are not fully focused on DPS control, and they are mainly conducted for an existing hardware prototype of an IBDC for an automotive application.”
BackgroundAn overall study of a Dual Active Bridge for bidirectional DC/DC conversion
Rodriguez Alonso, A., Sebastian, J., G. Lamar, D., Hernando, M. M., & Vazquez, A. (2010) · 2010 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2010.5617847 · Cited by 311
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310
High-Power Bidirectional DC–DC Converter for Aerospace Applications
Naayagi, R. T., Forsyth, A. J., & Shuttleworth, R. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2184771 · Cited by 305
“Although the DAB converter has an inherent soft-switching attribute, it is limited to a reduced operating range depending on voltage conversion ratio and output current [15], [17].”
BackgroundOptimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications
Shi, Y., Li, R., Xue, Y., & Li, H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2432093 · Cited by 298
“In [2] and [20], advanced modulation methods such as trapezoidal modulation (TZM) and triangular modulation (TRM) have been presented, where the transformer current is modulated in triangular or trapezoidal waveforms to reduce the conduction and the switching loss.”
MethodA Bidirectional LLC Resonant Converter With Automatic Forward and Backward Mode Transition
Jiang, T., Zhang, J., Wu, X., Sheng, K., & Wang, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2307329 · Cited by 264
A Novel ZVZCS Full-Bridge DC/DC Converter Used for Electric Vehicles
Pahlevaninezhad, M., Das, P., Drobnik, J., Jain, P. K., & Bakhshai, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178103 · Cited by 261
“So regular design methods [22], [30] of an AC inductor with air-gap has to be followed if an external inductor is to be designed for the series inductor, Ls .”
MethodVirtual Direct Power Control Scheme of Dual Active Bridge DC–DC Converters for Fast Dynamic Response
Song, W., Hou, N., & Wu, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2682982 · Cited by 256
Minimum-Backflow-Power Scheme of DAB-Based Solid-State Transformer With Extended-Phase-Shift Control
Shi, H., Wen, H., Chen, J., Hu, Y., Jiang, L., Chen, G., & Ma, J. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2819120 · Cited by 250
“trol scheme are equivalent or slightly higher than other schemes [31]–[33].”
Fundamental Duty Modulation of Dual-Active-Bridge Converter for Wide-Range Operation
Choi, W., Rho, K.-M., & Cho, B.-H. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2474135 · Cited by 244
“Based on the traditional loss analysis method, a loss model for the DAB converter has been derived [26].”
MethodA 300-kHz 6.6-kW SiC Bidirectional LLC Onboard Charger
Li, H., Zhang, Z., Wang, S., Tang, J., Ren, X., & Chen, Q. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2910048 · Cited by 237
“As the dc–ac converter is a buck type converter, the dc-link voltage has to be higher than the peak grid voltage so that the dc–ac converter can be grid-tied [9].”
BackgroundPahlevaninezhad, M., Drobnik, J., Jain, P. K., & Bakhshai, A. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2161063 · Cited by 223
“Different system structures, both bidirectional and unidirectional, have been reported in [23], [24], and [33] to be used for the EV power conditioning system.”
BackgroundGu, C., Zheng, Z., Xu, L., Wang, K., & Li, Y. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2416212 · Cited by 221
Hou, J., Chen, Q., Wong, S.-C., Tse, C. K., & Ruan, X. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2336811 · Cited by 210
Zhang, K., Shan, Z., & Jatskevich, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2555929 · Cited by 208
Wang, Z., & Li, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160284 · Cited by 200
“For example, it has been used in hybrid electric vehicles (HEVs) as auxiliary an power supply to replace the starter/alternator and to provide galvanic isolation between the low voltage battery and high voltage bus [2], [3].”
MethodXue, F., Yu, R., & Huang, A. Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2686307 · Cited by 199
“Many loss models have been well organized and documented in publications [28]–[33].”
BackgroundActive Balancing System for Electric Vehicles With Incorporated Low-Voltage Bus
Evzelman, M., Ur Rehman, M. M., Hathaway, K., Zane, R., Costinett, D., & Maksimovic, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2513432 · Cited by 197
Bi-Directional CLLC Converter With Synchronous Rectification for Plug-In Electric Vehicles
Zou, S., Lu, J., Mallik, A., & Khaligh, A. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2773430 · Cited by 185
“However, the soft switching region of a conventional DAB converter is only limited to a narrow output voltage range [9].”
BackgroundAn, F., Song, W., Yu, B., & Yang, K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2823364 · Cited by 190
“Meanwhile, the corresponding efficiency optimized schemes for DAB converters are discussed in [20]–[26].”
BackgroundUpputuri, R. P., & Subudhi, B. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3289965 · Cited by 184
“As PFC is a buck-type converter, hence grid-tied operations need a dc-link voltage greater than the maximum grid voltage [48].”
BackgroundWen, H., Xiao, W., & Su, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2316229 · Cited by 179
“Since the studies [11], [16] show that the conduction loss is dominant in the total power loss, the RMS value of the inductor”
BackgroundCostinett, D., Maksimovic, D., & Zane, R. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2228237 · Cited by 169
“Due to the high step-down ratio, it is expected that the high currents of the secondary side are capable of charging and discharging Cs quickly; further, though the analytical ZVS condition is I2 > 0, stray inductances on the high-current secondary are significant, causing ringing at vs and significantly affecting the…”
BackgroundFilba-Martinez, A., Busquets-Monge, S., Nicolas-Apruzzese, J., & Bordonau, J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2480753 · Cited by 168
“As shown in [16] and [17], the transformer copper”
BackgroundWang, Y.-F., Xue, L.-K., Wang, C.-S., Wang, P., & Li, W. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2496274 · Cited by 168
“[28]–[30] 11–16 V 240 V – 450 V 70 A/40 V 46 A/600 V 2 kW boost 92.”
BackgroundShe, X., Huang, A. Q., Wang, F., & Burgos, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2216245 · Cited by 161
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundShi, H., Wen, H., Hu, Y., & Jiang, L. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2811711 · Cited by 165
“The active bridge (DAB) converter is a popular topology of the IBDC converter [1-7].”
BackgroundEffective Test Bed of 380-V DC Distribution System Using Isolated Power Converters
Ryu, M.-H., Kim, H.-S., Baek, J.-W., Kim, H.-G., & Jung, J.-H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2399273 · Cited by 158
An Optimized Phase-Shift Modulation For Fast Transient Response in a Dual-Active-Bridge Converter
Li, X., & Li, Y.-F. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2294714 · Cited by 166
Grandjean, T. R. B., Barai, A., Hosseinzadeh, E., Guo, Y., McGordon, A., & Marco, J. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.05.016 · Cited by 161
He, P., Mallik, A., Sankar, A., & Khaligh, A. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2018.2881276 · Cited by 154
Modular Dual-Active Bridge Converter Architecture
Zumel, P., Ortega, L. D., Lázaro, A., Fernández, C., Barrado, A., Rodríguez, A., & Hernando, M. M. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2527723 · Cited by 160
“The DAB converter has been used in high-power [9], [10], [16], [20], [23]–[25] and mediumpower [11]–[15], [17], [21], [26] applications.”
MethodShi, H., Wen, H., Chen, J., Hu, Y., Jiang, L., & Chen, G. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2729417 · Cited by 150
“According to the previous study [6], the peak magnetic flux density can be expressed as”
High-Efficiency DAB Converter Using Switching Sequences and Burst Mode
Oggier, G. G., & Ordonez, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2440753 · Cited by 150
“The power transfer can be improved by controlling the series reactance and the reactive power [7], [14] between the two active bridges, which is proportional to the transformer leakage inductance.”
BackgroundIdling Port Isolation Control of Three-Port Bidirectional Converter for EVs
Kim, S., Song, H.-S., & Nam, K. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2172225 · Cited by 145
“An accurate power loss calculation method was developed for a DAB, and a loss table was made in [21].”
MethodAkagi, H., Yamagishi, T., Tan, N. M. L., Kinouchi, S.-I., Miyazaki, Y., & Koyama, M. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2331426 · Cited by 136
Oggier, G. G., Ordonez, M., Galvez, J. M., & Luchino, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2256150 · Cited by 134
“For these applications the dual active bridge (DAB) converter is a suitable alternative since high efficiency and high power density can be obtained [3]–[5].”
BackgroundDesign and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3059879 · Cited by 115
GaN-FET based dual active bridge DC-DC converter
Costinett, D., Nguyen, H., Zane, R., & Maksimovic, D. (2011) · 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2011.5744779 · Cited by 110
“[8], [10]-[13]), including transformer isolation with leakage inductance incorporated in circuit operation, soft-switching, and near-minimum voltage and current stresses on all components when operated as DCX (i.”
BackgroundShi, L., Lei, W., Li, Z., Huang, J., Cui, Y., & Wang, Y. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2640659 · Cited by 116
“energy storage [11], plug-in hybrid electric vehicles [12], uninterruptible power supply systems [13], and smart grids [14] has increased the popularity of the bidirectional dc–dc converters.”
BackgroundWang, X., Jiang, C., Lei, B., Teng, H., Bai, H. K., & Kirtley, J. L. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2575921 · Cited by 107
“2, an all-SiC-MOSFET-based three-phase boost-type PFC with a half-bridge LLC resonant converter contains fewer semiconductors compared with a three-level PFC or dual-active-bridge topology [9].”
BackgroundExtended Harmonics Based Phase Tracking for Synchronous Rectification in CLLC Converters
Sankar, A., Mallik, A., & Khaligh, A. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2874348 · Cited by 107
“Achieving zero voltage switching at all the MOSFETs in a DAB converter is quite challenging especially in applications with wide gain requirements [10], [11].”
BackgroundGammeter, C., Krismer, F., & Kolar, J. W. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2459378 · Cited by 105
“The conduction losses are calculated based on the ON-state channel resistance at an assumed junction temperature of 125 °C (see [29])”
MethodSelf-citationBlanchette, H. F., Bachir, T. O., & David, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2182021 · Cited by 105
Bhattacharjee, A. K., & Batarseh, I. E. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2943392 · Cited by 106
“A similar approach of reducing the rms current for the given power flow has been explored in [11]–[13] and [17].”
BackgroundZhang, Z., Thomsen, O. C., & Andersen, M. A. E. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2134051 · Cited by 102
“Its symmetric structure with phase-shift control enables the bidirectional power flow and ZVS operation for all power switches [17].”
BackgroundExtension of Soft-Switching Region of Dual-Active-Bridge Converter by a Tunable Resonant Tank
Yaqoob, M., Loo, K. H., & Lai, Y. M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2654505 · Cited by 100
“, depends on Lsci) under the gridded Region B corresponds to the low output current Io at low voltage that is not covered by the SCI designed previously as supercapacitor does not typically operate in this region and ZCS can be triggered with the aid of the energy stored in the MOSFETs’ parasitic inductances during ha…”
BackgroundInfluentialCandan, E., Shenoy, P. S., & Pilawa-Podgurski, R. C. N. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464805 · Cited by 108
“The dual active bridge (DAB) converter topology offers bidirectional power flow and symmetrical switch voltage ratings [39], [40].”
BackgroundQuadratic-Boost With Stacked Zeta Converter for High Voltage Gain Applications
Andrade, A. M. S. S., & Martins, M. L. D. S. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2706220 · Cited by 103
Liu, P., Chen, C., & Duan, S. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2896209 · Cited by 102
“Power loss analysis and efficiency optimization strategy are presented in [25]–[27], where the power loss modeling of the DAB converter is adopted to estimate the dissipated power.”
MethodPahlevaninezhad, M., Das, P., Drobnik, J., Jain, P. K., & Bakhshai, A. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2170098 · Cited by 100
Bu, Q., Wen, H., Shi, H., & Zhu, Y. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3136498 · Cited by 104
“rectional high-frequency power conversions in dc microgrids [9]–[18].”
BackgroundShan, Z., Jatskevich, J., Iu, H. H., & Fernando, T. L. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2797998 · Cited by 101
A Review of Electric Vehicle Auxiliary Power Modules: Challenges, Topologies, and Future Trends
Wang, C., Zheng, P., & Bauman, J. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3288393 · Cited by 104
“[4], [5], [21], [22], [23], [24], [25] and industry applications [26], due to its benefits of soft switching, bidirectional power flow, and high efficiency.”
BackgroundInfluentialPahlevaninezhad, M., Das, P., Drobnik, J., Moschopoulos, G., Jain, P. K., & Bakhshai, A. (2012) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2193894 · Cited by 103
Overview of Single-Stage High-Frequency Isolated AC–DC Converters and Modulation Strategies
Wu, F., Wang, K., Hu, G., Shen, Y., & Luo, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3210745 · Cited by 98
A Nonlinear Controller Based on a Discrete Energy Function for an AC/DC Boost PFC Converter
Das, P., Pahlevaninezhad, M., Drobnik, J., Moschopoulos, G., & Jain, P. K. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2232681 · Cited by 94
Akagi, H., Kinouchi, S.-I., & Miyazaki, Y. (2016) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2016.00004 · Cited by 84
Javed, W., Chen, D., Farrag, M. E., & Xu, Y. H. (2019) · Energies · doi:10.3390/en12061001 · Cited by 85
Guidi, G., Pavlovsky, M., Kawamura, A., Imakubo, T., & Sasaki, Y. (2010) · 2010 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2010.5617909 · Cited by 80
“MOSFETs are used to implement the high current bridge, since the required blocking voltage does not exceed about 100 V. Realization of the bridge structure is quite critical, since the high current to be switched and the low voltage available for the soft-switching capacitors make the ZVS behavior difficult to achieve…”
BackgroundMethodPerformance Evaluation of Modulation Techniques in Single-Phase Dual Active Bridge Converters
Noroozi, N., Emadi, A., & Narimani, M. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3087418 · Cited by 88
“The loss model of a DAB converter in [1] and [44], [45] can be considered in a more accurate design procedure.”
MethodDesign of a Highly efficient bidirectional isolated LLC resonant converter
Hillers, A., Christen, D., & Biela, J. (2012) · International Power Electronics and Motion Control Conference (IPEMC) · doi:10.1109/epepemc.2012.6397282 · Cited by 80
“The energy dissipated at turn-off in one of the secondary side switches is calculated according to [12]: ES,off = (LD + LS) · i(2)S,off · V2,pk V2,pk − V2 (21)”
MethodHarrye, Y. A., Ahmed, K. H., Adam, G. P., & Aboushady, A. A. (2014) · 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2014.6864653 · Cited by 71
“Investigation of DAB converter for electric vehicles and in energy storage system has been shown to be promising [4].”
BackgroundA Modified Dual Active Bridge Converter With Hybrid Phase-Shift Control for Wide Input Voltage Range
Shen, Y., Sun, X., Li, W., Wu, X., & Wang, B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2510033 · Cited by 85
“Hard switching does not only remarkably increase the switching losses, but also degrade the EMI characteristics, with excessive high-frequency ringing at the hard-switching transitions of secondary-side MOSFETs being observed in the gate-drive waveforms.”
BackgroundMethodInfluentialHou, N., Song, W., Li, Y., Zhu, Y., & Zhu, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2813995 · Cited by 80
“As a result, in order to improve the converter efficiency, various switching strategies were reported to directly minimize power losses by establishing the power-loss model of DAB dc–dc converters [13], [14].”
MethodYaqoob, M., Loo, K. H., & Lai, Y. M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2796137 · Cited by 80
“Circulating current and hard switching in conventional DAB converter are mainly due to the out-of-phase relationship between the tank current and bridge voltages [12], [13].”
BackgroundEverts, J., den Keybus, J. V., Krismer, F., Driesen, J., & Kolar, J. W. (2012) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2012.6165948 · Cited by 86
“2 (right inset), each high-frequency switch Sxx is implemented by a power transistor Txx, a diode Dxx, and a parasitic capacitor Cxx. Soft-switching operation occurs when a voltage transition is initiated by turn-off of the respective switch Sxx, commutating the current from the transistor Txx to the opposite diode Dx…”
BackgroundSelf-citationGao, R., She, X., Husain, I., & Huang, A. Q. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2679679 · Cited by 76
“(DAB) converters, which are ideal for isolated high-power applications [23], are connected to the dc terminal of the cascaded inverter, with the primary side connected in parallel at the low-”
BackgroundConceptualization and Multiobjective Optimization of the Electric System of an Airborne Wind Turbine
Kolar, J. W., Friedli, T., Krismer, F., Looser, A., Schweizer, M., Friedemann, R. A., Steimer, P. K., & Bevirt, J. B. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2269672 · Cited by 74
“b) Switching losses (from [32]): The switching losses of the full bridge and the NPC converter are calculated based on measurement values, according to [31].”
Self-citationTopology and application of bidirectional isolated dc-dc converters
Tan, N. M. L., Abe, T., & Akagi, H. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944690 · Cited by 83
“Therefore, high efficiency must be maintained in applications that require a wide range of operating voltage at both high-voltage and low-voltage sides, such as EVs, HEVs and, FEVs [26].”
BackgroundDistributed droop control of dc microgrid for improved voltage regulation and current sharing
Kumar, R., & Pathak, M. K. (2020) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2019.0983 · Cited by 71
Zhao, B., Yu, Q., Leng, Z., & Chen, X. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2181136 · Cited by 68
“Moreover, the corresponding phase shift changes the voltage across the transformer’s leakage inductance to manipulate the power flow direction and magnitude [11]–[15].”
BackgroundTang, Y., Hu, W., Zhang, B., Cao, D., Hou, N., Li, Y., Chen, Z., & Blaabjerg, F. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3126754 · Cited by 70
Multiple-Fault-Tolerant Dual Active Bridge Converter for DC Distribution System
Shi, H., Wen, H., Chen, G., Bu, Q., Chu, G., & Zhu, Y. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3106508 · Cited by 69
“efficiency, and wide soft-switching region [6]–[8].”
Direct AC–AC Converters Using Commercial Power Modules Applied to Voltage Restorers
Soeiro, T. B., Petry, C. A., Fagundes, J. C., & Barbi, I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045320 · Cited by 65
“Rated Power of Inductors and Transformers: The rated power of inductive components (inductors and transformers) is evaluated, in such a way that inductors are characterized by the rated power of an equivalent transformer [24], [25], as given by (4).”
BackgroundDesign of a minimum weight dual active bridge converter for an Airborne Wind Turbine system
Friedemann, R. A., Krismer, F., & Kolar, J. W. (2012) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2012.6165868 · Cited by 63
“Switching Losses The switching losses of the full bridge and the NPC converter are calculated based on measurement values, according to [10].”
MethodInfluentialSelf-citationLi, J., Luo, Q., Mou, D., Wei, Y., & Zhang, X. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3114321 · Cited by 65
Ataullah, H., Iqbal, T., Khalil, I. U., Ali, U., Blažek, V., Prokop, L., & Ullah, N. (2022) · Energies · doi:10.3390/en15238944 · Cited by 51
“The dual active bridge (DAB) is a converter that is employed in solid-state transformers [1–3], applications like transportation [4,5], and renewable energy [6].”
BackgroundSong, Y., & Wang, B. (2014) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2014.2306093 · Cited by 62
A Current-Fed Isolated Bidirectional DC–DC Converter
Sun, X., Wu, X., Shen, Y., Li, X., & Lu, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2623306 · Cited by 64
“For high voltage MOSFET transistors, the reverse current that is greater than 2 A is supposed to be sufficient to recharge the parasitic output capacitance within a 200 ns dead-time interval, leading to the realization of the practical ZVS [22].”
BackgroundReview of Modeling, Modulation, and Control Strategies for the Dual-Active-Bridge DC/DC Converter
He, J., Chen, Y., Lin, J., Chen, J., Li, C., & Wang, Y. (2023) · Energies · doi:10.3390/en16186646 · Cited by 62
Hirose, T., Takasaki, M., & Ishizuka, Y. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2327147 · Cited by 61
“Such applications include uninterruptible power systems [1], automotive [2]–[4], and energy storage systems [5].”
BackgroundCoelho, S., Monteiro, V., & Afonso, J. L. (2025) · Sustainability · doi:10.3390/su17062336 · Cited by 59
Design and Implementation of a Two-Stage Grid-Connected High Efficiency Power Load Emulator
Kanaan, H. Y., Caron, M., & Al‐Haddad, K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295023 · Cited by 62
“Mathematical modeling of the converter has been proposed either for an accurate calculation of the core-losses aimed to optimize the design of the converter [6], [7], or to improve the transient response and stability [8], [9] of the control loop.”
BackgroundShin, C.-J., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293781 · Cited by 56
“7 shows conventional charger circuits comprised of FB inverter and bi-directional dc/dc converters of FB converter and DAB converter [7], [13].”
BackgroundMethodZhang, Y., Wang, S., & Chu, Y. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2972342 · Cited by 58
Peak Current Control and Feed-Forward Compensation of a DAB Converter
Vázquez, N., & Liserre, M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2949523 · Cited by 55
“THE double active bridge (DAB) converter is one of the most employed isolated dc–dc converters for different applications, such as the solid-state transformers [1]–[7], multipleinput converters [8]–[12], and more applications [13], [14].”
BackgroundA LLC-Type Dual-Bridge Resonant Converter: Analysis, Design, Simulation, and Experimental Results
Li, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2291207 · Cited by 54
Metadata
- Authors
- Krismer, F., & Kolar, J. W.
- Affiliations
- ETH Zurich (CH)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-03
- Volume
- 57
- Issue
- 3
- Pages
- 881-891
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2118203870
- Cited by
- 470
- References
- 26
- Citations by year
- 2026: 21 · 2025: 32 · 2024: 24 · 2023: 24 · 2022: 26 · 2021: 34 · 2020: 29 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 36 · 2015: 31 · 2014: 35 · 2013: 20 · 2012: 26
- FWCI
- 15.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- dual active bridge converter, power loss modeling, bidirectional DC-DC converter, fuel cell vehicles, 12V battery, high-voltage DC bus, power density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.