Overcurrent Limiting in Grid-Forming Inverters: A Comprehensive Review and Discussion
Open accessThe DOI matches its Crossref record; 105 of the 105 references it cites were found in a registry or an index.
Abstract
Grid-forming (GFM) inverters are increasingly recognized as a solution to facilitate massive grid integration of inverter-based resources and enable 100% power-electronics-based power systems. However, the overcurrent characteristics of GFM inverters exhibit major differences from those of conventional synchronous machines. Accordingly, an in-depth characterization of GFM current-limiting strategies is needed to ascertain their performance during off-nominal conditions. Although GFM current-limiting controls are primarily necessary to protect the inverter power stage, they determine the inverter behavior during and after an off-nominal system disturbance. As a result, they can profoundly impact device-level stability, transient system stability, power system protection, and fault recovery. This paper offers a comprehensive review of state-of-the-art current-limiting techniques for GFM inverters and outlines open challenges where innovative solutions are needed. One key contribution of this paper is the use of graphical methods that allow for intuitive understanding and visually-aided comparisons of current-limiting methods. With this approach, we evaluate various performance criteria for different limiting methods, such as fault current contribution, voltage support, stability, and post-fault recovery. We also discuss the latest standards and trends as they require inverter dynamics under off-nominal conditions and outline pathways for future developments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Voltage‐Sourced Converters in Power Systems: Modeling, Control, and Applications
Yazdani, A., & Iravani, R. (2010) · Wiley eBooks · doi:10.1002/9780470551578 · Cited by 2,264
Power System Stability and Control
(2007) · CRC Press eBooks · doi:10.1201/9781420009248 · Cited by 1,828
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
Kroposki, B., Johnson, B., Zhang, Y., Gevorgian, V., Denholm, P., Hodge, B.-M., & Hannegan, B. (2017) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2016.2637122 · Cited by 1,367
Self-citationDecoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
A new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097
He, J., & Li, Y. W. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168592 · Cited by 759
Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters
Wang, X., Li, Y. W., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382565 · Cited by 670
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Huang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749259 · Cited by 602
Virtual Impedance Current Limiting for Inverters in Microgrids With Synchronous Generators
Paquette, A. D., & Divan, D. M. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2345877 · Cited by 580
Anti-windup design: an overview of some recent advances and open problems
Tarbouriech, S., & Turner, M. (2009) · IET Control Theory & Applications · doi:10.1049/iet-cta:20070435 · Cited by 564
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Power System Stability With a High Penetration of Inverter-Based Resources
Gu, Y., & Green, T. C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3179826 · Cited by 460
Research Roadmap on Grid-Forming Inverters
Lin, Y., Eto, J., Johnson, B., Flicker, J., Lasseter, R., Villegas Pico, H., Seo, G.-S., Pierre, B., & Ellis, A. (2020) · doi:10.2172/1721727 · Cited by 419
Self-citationDu, W., Chen, Z., Schneider, K. P., Lasseter, R. H., Pushpak Nandanoori, S., Tuffner, F. K., & Kundu, S. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2942491 · Cited by 377
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371 · cited 2×
“These requirements are based on the characteristics of SGs and decades of operational experience; however, with the proliferation of IBRs in the grid, the need for inverter-oriented fault ride-through and dynamic voltage-support requirements has become prominent [12], [165].”
Huang, L., Xin, H., Wang, Z., Wu, K., Wang, H., Hu, J., & Lu, C. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2740424 · Cited by 342
Control of Distributed Generation Systems— Part I: Voltages and Currents Control
Marwali, M. N., & Keyhani, A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836685 · Cited by 329
Bottrell, N., & Green, T. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2279162 · Cited by 311
Rokrok, E., Qoria, T., Bruyere, A., Francois, B., & Guillaud, X. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3107959 · Cited by 311
Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2521325 · Cited by 299
Overview on Grid-Forming Inverter Control Methods
Unruh, P., Nuschke, M., Strauß, P., & Welck, F. (2020) · Energies · doi:10.3390/en13102589 · Cited by 291
Qoria, T., Gruson, F., Colas, F., Denis, G., Prevost, T., & Guillaud, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959085 · Cited by 256
Sadeghkhani, I., Hamedani Golshan, M. E., Guerrero, J. M., & Mehrizi-Sani, A. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517201 · Cited by 255
Current limiting algorithms and transient stability analysis of grid-forming VSCs
Qoria, T., Gruson, F., Colas, F., Kestelyn, X., & Guillaud, X. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106726 · Cited by 249
Characteristics and Restraining Method of Fast Transient Inrush Fault Currents in Synchronverters
Shuai, Z., Huang, W., Shen, C., Ge, J., & Shen, Z. J. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2652362 · Cited by 246
Virtual-Impedance-Based Fault Current Limiters for Inverter Dominated AC Microgrids
Lu, X., Wang, J., Guerrero, J. M., & Zhao, D. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2594811 · Cited by 220
Liu, T., Wang, X., Liu, F., Xin, K., & Liu, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122744 · Cited by 200 · cited 3×
“This method is studied in [42] and [43], where the power set points, P (cid:2) and Q (cid:2) , are dynamically rescaled as a function of the magnitude of the output voltage, E (see Fig.”
Grid-Forming Control for Solar PV Systems With Power Reserves
Pawar, B., Batzelis, E., Chakrabarti, S., & Pal, B. (2021) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2021.3074066 · Cited by 197
Saitou, M., & Shimizu, T. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/psec.2002.1022375 · Cited by 191
Fan, B., & Wang, X. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3173160 · Cited by 190
Mahamedi, B., Eskandari, M., Fletcher, J. E., & Zhu, J. (2020) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2887149 · Cited by 185
Seo, G.-S., Colombino, M., Subotic, I., Johnson, B., Gros, D., & Dorfler, F. (2019) · 2019 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2019.8722028 · Cited by 182 · cited 2×
“2, typical primary control methods include droop control [16], virtual synchronous machine (VSM) control [17], and dispatchable virtual oscillator control (dVOC) [18], [19], [20].”
BackgroundSelf-citationA Grid-compatible Virtual Oscillator Controller: Analysis and Design
Lu, M., Dutta, S., Purba, V., Dhople, S. V., & Johnson, B. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8913128 · Cited by 178
Self-citationZarei, S. F., Mokhtari, H., Ghasemi, M. A., & Blaabjerg, F. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2844082 · Cited by 177
Denis, G., Prevost, T., Debry, M., Xavier, F., Guillaud, X., & Menze, A. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2017.0369 · Cited by 172
Virtual Oscillator Grid-Forming Inverters: State of the Art, Modeling, and Stability
Lu, M. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3163377 · Cited by 168
Self-citationWu, H., & Wang, X. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3135693 · Cited by 166
Zamani, M. A., Yazdani, A., & Sidhu, T. S. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2205713 · Cited by 161
Impacts of Current Limiting on the Transient Stability of the Virtual Synchronous Generator
Saffar, K. G., Driss, S., & Ajaei, F. B. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3208800 · Cited by 155
Qoria, T., Wu, H., Wang, X., & Colak, I. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3232987 · Cited by 140
Christensen, P., Andersen, G. K., Seidel, M., Bolik, S. M., Engelken, S., Knüppel, T., Krontiris, A., Würflinger, K., Bülo, T., Jahn, J., et al. (2020) · Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) · Cited by 136
Zhang, Y., Zhang, C., Yang, R., Molinas, M., & Cai, X. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3236620 · Cited by 135
Fault Recovery Analysis of Grid-Forming Inverters With Priority-Based Current Limiters
Fan, B., & Wang, X. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3221209 · Cited by 131 · cited 3×
“3(b), it is possible—after saturating the magnitude of the reference signal—to manipulate and prioritize the active or reactive current during the disturbance [23], [31], [33], [34], [35], [36], [37].”
BackgroundRosso, R., Engelken, S., & Liserre, M. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3095025 · Cited by 126
Survivability of Autonomous Microgrid During Overload Events
Du, W., Lasseter, R. H., & Khalsa, A. S. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2829438 · Cited by 122
An Adaptive Fault Ride-Through Scheme for Grid-Forming Inverters Under Asymmetrical Grid Faults
Li, Z., Chan, K. W., Hu, J., & Or, S. W. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3135641 · Cited by 121 · cited 2×
“Freytes et al. [154], Awal et al. [155] proposed direct current limiters, and Li et al. [28] and, Avdiaj et al. [153] proposed VI current limiters in the DDSRF.”
Single Line to Ground Fault Detection in a Non-Effectively Grounded Distribution Network
Wang, X., Gao, J., Wei, X., Zeng, Z., Wei, Y., & Kheshti, M. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2873017 · Cited by 109
Huang, L., Wu, C., Zhou, D., & Blaabjerg, F. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3199906 · Cited by 107
Use of voltage limits for current limitation in grid-forming converters
Chen, J., Prystupczuk, F., & O’Donnell, T. (2020) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2019.02660 · Cited by 105
A Novel Transient Control Strategy for VSC-HVDC Connecting Offshore Wind Power Plant
Moawwad, A., Moursi, M. S. E., & Xiao, W. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2325951 · Cited by 101
Current-Limiting Droop Control of Grid-Connected Inverters
Zhong, Q., & Konstantopoulos, G. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2622402 · Cited by 101
Modelling and Analysis of Fault Behaviour of Inverter Microgrids to Aid Future Fault Detection
Brucoli, M., Green, T. C., & McDonald, J. D. F. (2007) · International Conference on System of Systems Engineering · doi:10.1109/sysose.2007.4304253 · Cited by 97
Kabalan, M., Singh, P., & Niebur, D. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2752146 · Cited by 89
Subotić, I., Groß, D., Colombino, M., & Dörfler, F. (2020) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2020.3047368 · Cited by 89
Effects of current limit for grid forming converters on transient stability: Analysis and solution
Kkuni, K. V., & Yang, G. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.109919 · Cited by 89
Grid-Forming Control With Current Limitation for MMC Under Unbalanced Fault Ride-Through
Freytes, J., Li, J., de PREVILLE, G., & Thouvenin, M. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3053148 · Cited by 88
Evaluation of current limiting methods for grid forming inverters in medium voltage microgrids
Gkountaras, A., Dieckerhoff, S., & Sezi, T. (2015) · 2015 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7309831 · Cited by 83
Control of a Multiple Source Microgrid With Built-in Islanding Detection and Current Limiting
Bloemink, J. M., & Iravani, M. R. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2198497 · Cited by 70
Dual Voltage–Current Control to Provide Grid-Forming Inverters With Current Limiting Capability
Erdocia, J., Urtasun, A., & Marroyo, L. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3133806 · Cited by 67
Model Reduction for Inverters With Current Limiting and Dispatchable Virtual Oscillator Control
Ajala, O., Lu, M., Johnson, B., Dhople, S. V., & Domínguez-García, A. D. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3083488 · Cited by 65
Self-citationPost-fault prediction of transient instabilities using stacked sparse autoencoder
Mahdı, M., & Genc, I. V. M. (2018) · Electric Power Systems Research · doi:10.1016/j.epsr.2018.08.009 · Cited by 63
Awal, M. A., Rachi, M. R. K., Yu, H., Husain, I., & Lukic, S. M. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3227729 · Cited by 59
Narula, A., Imgart, P., Bongiorno, M., Beza, M., Svensson, J., & Hasler, J.-P. (2023) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2023.3246728 · Cited by 57
Lin, X., Liang, Z., Zheng, Y., Lin, Y., & Kang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2879191 · Cited by 54
Virtual resistance principle for the overcurrent protection of PWM voltage source inverter
Salha, F., Colas, F., & Guillaud, X. (2010) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope.2010.5638965 · Cited by 52
Controller-Saturation-Based Transient Stability Enhancement for Grid-Forming Inverters
Luo, C., Ma, X., Liu, T., & Wang, X. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3213757 · Cited by 52
Optimal short‐circuit current control of the grid‐forming converter during grid fault condition
Liu, C., Cai, X., Li, R., & Yang, R. (2021) · IET Renewable Power Generation · doi:10.1049/rpg2.12149 · Cited by 51
Current limiting leads to virtual power angle synchronous instability of droop-controlled converters
Huang, L., Zhang, L., Xin, H., Wang, Z., & Gan, D. (2016) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2016.7741667 · Cited by 47
Jeong, S., & Jang, G. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3169176 · Cited by 46
Wang, Y., Kuang, Y., & Xu, Q. (2023) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2023.3248964 · Cited by 42
Comparison of Droop Control and Virtual Oscillator Control Realized by Andronov-Hopf Dynamics
Lu, M., Purba, V., Dhople, S. V., & Johnson, B. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9254645 · Cited by 41
Self-citationZhao, X., & Flynn, D. (2020) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel49091.2020.9265733 · Cited by 41
UNIFI Specifications for Grid-Forming Inverter-Based Resources (V. 2)
Kroposki, B., & USDOE Office of Energy Efficiency and Renewable Energy (EERE) (2024) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/2329414 · Cited by 41
Model Reduction and Dynamic Aggregation of Grid-Forming Inverter Networks
Ajala, O., Baeckeland, N., Johnson, B., Dhople, S. V., & Domínguez-García, A. D. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3229970 · Cited by 40
Self-citationAn improved control strategy of virtual synchronous generator under symmetrical grid voltage sag
Lou, G., Yang, Q., Gu, W., & Zhang, J. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.106093 · Cited by 39
Rosso, R., Engelken, S., & Liserre, M. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9236314 · Cited by 37
Du, W., Nguyen, Q., Liu, Y., & Mohiuddin, S. M. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9947505 · Cited by 35
Projected grid-forming control for current-limiting of power converters
Groß, D., & Dörfler, F. (2019) · Allerton Conference on Communication, Control, and Computing · doi:10.1109/allerton.2019.8919856 · Cited by 34
Grid-forming Inverter Experimental Testing of Fault Current Contributions
Gurule, N. S., Hernandez-Alvidrez, J., Reno, M. J., Summers, A., Gonzalez, S., & Flicker, J. (2019) · 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC) · doi:10.1109/pvsc40753.2019.8980892 · Cited by 34
Hirsching, C., Goertz, M., Wenig, S., Bisseling, A., Suriyah, M., & Leibfried, T. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3205055 · Cited by 30
Model Specification of Droop-Controlled, Grid-Forming Inverters (GFMDRP_A)
Du, W., Liu, Y., Tuffner, F., Huang, R., & Huang, Z. H. (2021) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1899301 · Cited by 25
Du, W., & Mohiuddin, S. M. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362015 · Cited by 24
Experimental Evaluation of Grid-Forming Inverters Under Unbalanced and Fault Conditions
Gurule, N. S., Hernandez-Alvidrez, J., Darbali-Zamora, R., Reno, M. J., & Flicker, J. D. (2020) · IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon43393.2020.9254562 · Cited by 22
Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults
Baeckeland, N., & Seo, G. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10213960 · Cited by 22
Self-citationEnhanced TVI for Grid Forming VSC under Unbalanced Faults
Zubiaga, M., Cardozo, C., Prévost, T., Sanchez-Ruiz, A., Olea, E., Izurza-Moreno, P., Khan, S. H., & Arza, J. (2021) · Energies · doi:10.3390/en14196168 · Cited by 21
On the Passivity of Grid-Forming Converters — Role of Virtual Impedance
Miranbeigi, M., Gajare, P. M., Benzaquen, J., Kandula, P., & Divan, D. M. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773656 · Cited by 18
Grid-Forming Nature Retaining Fault Ride-Through Control
Awal, M. A., Rachi, M. R. K., Yu, H., Schröder, S., Dannehl, J., & Husain, I. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131145 · Cited by 16
Blackstart of Unbalanced Microgrids Using Grid-Forming Inverter with Voltage Balancing Capability
Kim, T., Santoso, S., da Cunha, V. C., Wang, W., Dugan, R. C., Ramasubramanian, D., & Maitra, A. (2022) · IEEE PES Transmission and Distribution Conference and Exhibition · doi:10.1109/td43745.2022.9816943 · Cited by 11
PLL-Less Three-Phase Droop-Controlled Inverter with Inherent Current-Limiting Property
Dedeoğlu, S., & Konstantopoulos, G. C. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927219 · Cited by 10
Transient Stability Analysis and Enhancement for VSG with Virtual Impedance based Current Limitation
Luo, C., Chen, Y., Xu, Y., Wang, Z., & Li, Q. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968894 · Cited by 10
Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting
Baeckeland, N., & Seo, G. (2023) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel52896.2023.10221088 · Cited by 10
Self-citationEvaluation of Current-Limiting Strategies for Grid-Forming Inverters
Shirazi, M., Groß, D., Light, D., VanderMeer, J., & Morgan, T. C. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362373 · Cited by 10
Hybrid Threshold Virtual Impedance for Fault Current Limiting in Grid-Forming Converters
Zeng, Z., Bhagwat, P., Saeedifard, M., & Groß, D. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362897 · Cited by 10
Huang, L., Wu, C., Zhou, D., & Blaabjerg, F. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9948159 · Cited by 9
A Comprehensive Study of Orthogonal Signal Generation Schemes for Single Phase Systems
Gautam, S., Hassan, W., Bhatta, A., Lu, D. D., & Xiao, W. (2021) · International Conference on Power Electronics and Energy (ICPEE) · doi:10.1109/icpee50452.2021.9358671 · Cited by 8
Liang, G., Yadav, G. N. B., Rodríguez, E., Farivar, G. G., & Pou, J. (2022) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec55080.2022.10058368 · Cited by 6
Cited by
Small-Signal Analysis of Current-Limiting Grid-Forming Inverters
Yang, B., Baeckeland, N., & Seo, G.-S. (2026) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2026.3655646 · Cited by 2
Self-citation
Metadata
- Authors
- Baeckeland, N., Chatterjee, D., Lu, M., Johnson, B., & Seo, G.-S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2024-11
- Volume
- 39
- Issue
- 11
- Pages
- 14493-14517
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W4400770948
- Cited by
- 271
- References
- 105
- FWCI
- 42.89
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.