A Method for Generating Precise Temporal Patterns of Retinal Spiking Using Prosthetic Stimulation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The goal of retinal prosthetic devices is to generate meaningful visual information in patients that have lost outer retinal function. To accomplish this, these devices should generate patterns of ganglion cell activity that closely resemble the spatial and temporal components of those patterns that are normally elicited by light. Here, we developed a stimulus paradigm that generates precise temporal patterns of activity in retinal ganglion cells, including those patterns normally generated by light. Electrical stimulus pulses (≥1-ms duration) elicited activity in neurons distal to the ganglion cells; this resulted in ganglion cell spiking that could last as long as 100 ms. However, short pulses, <0.15 ms, elicited only a single spike within 0.7 ms of the leading edge of the pulse. Trains of these short pulses elicited one spike per pulse at frequencies ≤250 Hz. Patterns of short electrical pulses (derived from normal light elicited spike patterns) were delivered to ganglion cells and generated spike patterns that replicated the normal light patterns. Finally, we found that one spike per pulse was elicited over almost a 2.5:1 range of stimulus amplitudes. Thus a common stimulus amplitude could accommodate a 2.5:1 range of activation thresholds, e.g., caused by differences arising from cell biophysical properties or from variations in electrode-to-cell distance arising when a multielectrode array is placed on the retina. This stimulus paradigm can generate the temporal resolution required for a prosthetic device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“…diseases do not target inner retinal neurons; large populations of inner retinal neurons remain morphologically intact, even in patients blind for many years (Humayun et al. 1999; Santos et al. 1997; Stone et al. 1992; but also see also Jones and Marc 2005; Marc and Jones 2003; Marc et al. 2003).”
BackgroundRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 2×
“Several research groups are developing retinal prosthetic devices with the hope of providing meaningful visual information to blind patients (Chow et al. 2004; Humayun et al. 2003; Rizzo et al. 2003a,b; Zrenner et al. 1997).”
BackgroundCogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162 · cited 1×
“New electrode materials under development have higher charge density limits (Cogan et al. 2005), and electrodes with symmetrical designs (circular, hemispherical) will reduce the elevated charge densities arising from irregular shapes.”
BackgroundJensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159 · cited 6×
“Jensen et al. (2005a) reported that the spiking response to electrical stimulation consists of short-and long-latency components and that the latency of the late component ranged from 8 to 60 ms.”
BackgroundResultInfluential
Cited by
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Selective activation of bipolar cells and ganglion cells is possible by altering the stimulus waveforms (Freeman et al., 2010; Fried et al., 2006; Margalit and Thoreson, 2006).”
Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
“RGCs can accurately follow electrical stimulation with rates up to 250 Hz, which corresponds to the maximum spike frequencies in the natural light responses (Fried et al 2006).”
BackgroundImplantable microcoils for intracortical magnetic stimulation
Lee, S. W., Fallegger, F., Casse, B. D. F., & Fried, S. I. (2016) · Science Advances · doi:10.1126/sciadv.1600889 · Cited by 151
“3F, bottom); note that the presence of the positivegoing after-hyperpolarization that closely follows each stimulus provides a clear marker for the presence of an elicited action potential (24).”
Self-citationA model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2019) · Scientific Reports · doi:10.1038/s41598-019-45416-4 · Cited by 143
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107
“42 ms—a value very similar to electrophysiology estimates of the integration of current by ganglion cells in rodent and primate models.(26,38,49) It should be noted that intracellular current injection results in slower time constants, ranging from 3.”
Spatially patterned electrical stimulation to enhance resolution of retinal prostheses
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.2882-13.2014 · Cited by 103
Resolution of the epiretinal prosthesis is not limited by electrode size
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2140132 · Cited by 102
“a natural fashion [29] that the brain expects, for the purpose of reducing perceptual threshold.”
BackgroundMethodJepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97
“…would require precise control over the timing of spikes in individual RGCs. Highly precise temporal control of spike timing has been demonstrated (Fried et al., 2006; Sekirnjak et al., 2006, 2008; Hottowy et al., 2012), but it is less clear whether single-cell spatial resolution is possible,…”
BackgroundInfluentialSpatiotemporal Interactions in Retinal Prosthesis Subjects
Horsager, A., Greenberg, R. J., & Fine, I. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3746 · Cited by 95
Activation of ganglion cells and axon bundles using epiretinal electrical stimulation
Grosberg, L. E., Ganesan, K., Goetz, G. A., Madugula, S. S., Bhaskhar, N., Fan, V., Li, P., Hottowy, P., Dabrowski, W., Sher, A., et al. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00750.2016 · Cited by 70
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Hottowy, P., Skoczeń, A., Gunning, D. E., Kachiguine, S., Mathieson, K., Sher, A., Wiącek, P., Litke, A. M., & Dąbrowski, W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066005 · Cited by 67
The appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60
Temporal interactions during paired-electrode stimulation in two retinal prosthesis subjects
Horsager, A., Boynton, G. M., Greenberg, R. J., & Fine, I. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5282 · Cited by 48
Computational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
“This observation is in contrast to previous efforts to optimize the selectivity of activation, i.e. activating one or a few target cells while not activating non-target cells (see section 3 above) (Fried et al 2006, Wong et al 2009, Freeman et al 2010, Jepson et al 2013, 2014b, Lee and Im 2019).”
ResultThe response of retinal neurons to high-frequency stimulation
Cai, C., Twyford, P., & Fried, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036009 · Cited by 38
“The properties of the bursts that arise through indirect activation are thought to be shaped by the strength with which presynaptic neurons are activated: strongly activated presynaptic cells lead to larger and more prolonged releases of excitatory neurotransmitter, which in turn leads to longer and stronger spike bur…”
BackgroundSelf-citationGlobal activity shaping strategies for a retinal implant
Spencer, M. J., Kameneva, T., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf071 · Cited by 28
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab3913 · Cited by 24
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Yan, Y., Lu, Y., Li, M., Ma, Z., Cao, P., Chen, Y., Sun, X., Chai, X., Ren, Q., & Li, L. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-17543 · Cited by 20
Corna, A., Ramesh, P., Jetter, F., Lee, M.-J., Macke, J. H., & Zeck, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0679 · Cited by 18
Cicione, R., Fallon, J. B., Rathbone, G. D., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14754 · Cited by 17
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2018) · doi:10.1101/453035 · Cited by 13
Metadata
- Authors
- Fried, S. I., Hsueh, H. A., & Werblin, F. S.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2006-02
- Volume
- 95
- Issue
- 2
- Pages
- 970-978
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W1967165001
- Cited by
- 211
- References
- 4
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.