The DOI matches its Crossref record; 226 of the 226 references it cites were found in a registry or an index.
Recommendations for Blood Pressure Measurement in Humans and Experimental Animals: Part 1: Blood Pressure Measurement in Humans: A Statement for Professionals From the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
Open accessAbstract
Accurate measurement of blood pressure is essential to classify individuals, to ascertain blood pressure–related risk, and to guide management. The auscultatory technique with a trained observer and mercury sphygmomanometer continues to be the method of choice for measurement in the office, using the first and fifth phases of the Korotkoff sounds, including in pregnant women. The use of mercury is declining, and alternatives are needed. Aneroid devices are suitable, but they require frequent calibration. Hybrid devices that use electronic transducers instead of mercury have promise. The oscillometric method can be used for office measurement, but only devices independently validated according to standard protocols should be used, and individual calibration is recommended. They have the advantage of being able to take multiple measurements. Proper training of observers, positioning of the patient, and selection of cuff size are all essential. It is increasingly recognized that office measurements correlate poorly with blood pressure measured in other settings, and that they can be supplemented by self-measured readings taken with validated devices at home. There is increasing evidence that home readings predict cardiovascular events and are particularly useful for monitoring the effects of treatment. Twenty-four-hour ambulatory monitoring gives a better prediction of risk than office measurements and is useful for diagnosing white-coat hypertension. There is increasing evidence that a failure of blood pressure to fall during the night may be associated with increased risk. In obese patients and children, the use of an appropriate cuff size is of paramount importance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Many studies utilized 24-hour (or 48-hour) ambulatory BP measurements, considered to be the most accurate method to diagnose hypertension and the best predictor of future cardiovascular risk.154”
From Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment (2019) · cites this paper as [154]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Blood pressure recorded at each visit was the mean of two or more BP measurements obtained using the recommended measurement guidelines from the American Heart Association [22].”
In the citing paper
“As with best-practice measurement of BP under resting conditions, operators must follow a standardized protocol to measure exercise BP because deviation from recommended protocols will increase the likelihood of BP measurement error [49].”
From The Identification and Management of High Blood Pressure Using Exercise Blood Pressure: Current Evidence and Practical Guidance (2022) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
Self-citationPrevalence and trends in obesity among US adults, 1999–2000
Flegal, K. M. (2002) · JAMA · doi:10.1001/jama.288.14.1723 · Cited by 6,190
US Environmental Protection Agency
Liu, X. (1998) · Choice Reviews Online · doi:10.5860/choice.35-4455 · Cited by 5,887
Is Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. A. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,756
Ambulatory blood pressure. An independent predictor of prognosis in essential hypertension.
Verdecchia, P., Porcellati, C., Schillaci, G., Borgioni, C., Ciucci, A., Battistelli, M., Guerrieri, M., Gatteschi, C., Zampi, I., Santucci, A., et al. (1994) · Hypertension · doi:10.1161/01.hyp.24.6.793 · Cited by 1,671
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationHuman blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C. M., Flack, J. M., Frohlich, E. D., Hill, M. D., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,592
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Research works printed but not linked: 35
- Verdecchia P, Schillaci G, Borgioni C, Ciucci A, Gattobigio R, Porcellati C. Nocturnal pressure is the true pressure. Blood Press Monit. 1996; 1 (Suppl 2): S81–S85.
- 10.1161/circ.103.9.1245 · DOI
- 10.1161/hyp.36.5.801 · DOI
- 10.1161/hyp.25.6.1276 · DOI
- 10.1161/circ.100.4.354 · DOI
- 10.1161/circ.103.9.1245 · DOI
- Pickering TG. White coat hypertension. In: Izzo JL Black HR eds. Hypertension Primer third edition. Dallas: American Heart Association; 2003.
- 10.1161/circ.102.10.1139 · DOI
- Low PA. Clinical Autonomic Disorders: Evaluation and Management second ed. Philadelphia: Lippincott-Raven; 1997.
- 10.1161/str.27.8.1316 · DOI
- 10.1161/circ.8.2.232 · DOI
- 10.1161/circ.88.5.8222141 · DOI
- Cates EM, Schlussel YR, James GD, Pickering TG. A validation study of the Spacelabs 90207 ambulatory blood pressure monitor. J Ambul Monitor. 1990; 3: 149–154.
- Penaz J. Photo-electric measurement of blood pressure volume and flow in the finger. Digest Tenth International Conference Medical Biological Engineering. Dresden; 1973:104.
- Ware RW, Laenger CJ. Indirect blood pressure measurement by Doppler ultrasonic kinetoarteriography. Proc 20th Annual Conference Engineering Medical Biology. 1967; 9: 27–30.
- Wonka F, Thummler M, Schoppe A. Clinical test of a blood pressure measurement device with a wrist cuff. Blood Press Monit. 1996; 1: 361–366.
- 10.1161/hyp.36.4.484 · DOI
- Grim CE, Grim CM, Li J. Entering medical students who say they have been trained to take blood pressure do not follow American Heart Association guidelines. Am J Hypertens. 1999; 12.
- 10.1001/archinte.1984.00350190188032 · DOI
- Beevers DG, Beevers M, Zezulka AV, Hornby R, Herod J. Standards for blood pressure measuring devices. BMJ (Clin Res Ed). 1987; 294: 1614.
- O’Brien E, Atkins N, O’Malley K. Selecting the correct bladder according to distribution of arm circumference in the population (abstr). Hypertension. 1993; 11: 1149–1150.
- 10.1161/circ.68.4.6616774 · DOI
- Ljungvall P, Thorvinger B, Thulin T. The influence of a heart level pillow on the result of blood pressure measurement. J Hum Hypertens. 1989; 3: 471–474.
- Rose G. Standardisation of observers in blood pressure measurement. Lancet. 1965; 10: 673–674.
- 10.1161/circ.28.1.20 · DOI
- 10.1001/jama.1967.03130150084015 · DOI
- 10.1161/hyp.35.5.1032 · DOI
- Myers MG. Self-measurement of blood pressure at home: the potential for reporting bias. Blood Press Monit. 1998; 3 (suppl 1): S19–S22.
- Imai Y, Ohkubo T, Tsuji I, Nagai K, Satoh H, Hisamichi S, Abe K. Prognostic value of ambulatory and home blood pressure measurements in comparison to screening blood pressure measurements: a pilot study in Ohasama. Blood Press Monit. 1996; 1 (Suppl 2): S51–S58.
- 10.1161/hyp.32.2.255 · DOI
- Verdecchia P Bentivoglia M Providenza M Savino K Corea L. Reliability of home self-recorded arterial pressure in essential hypertension in relation to the stage of the disease. In: Germano G ed. Blood pressure recording in the clinical management of hypertension. Rome: Ediziono Pozzi; 1985: 40–42.
- 10.1161/circ.98.18.1892 · DOI
- 10.1161/hyp.31.2.712 · DOI
- Prineas RJ Elkwiry ZM. Epidemiology and measurement of high blood pressure in children and adolescents. In: Loggie JMH ed. Pediatric and Adolescent Hypertension. Boston MA: Blackwell Scientific Publications; 1992: 91–103.
- Brown MA Davis GK. Hypertension in pregnancy. In: Mancia G Chalmers J Julius S Saruta T Weber MA Ferrari AU Wilkinson IB ed. Manual of Hypertension. London: Harcourt Publishers Limited; 2002: 579–597.
Cited by
Sorted by citations
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationAstrup, A., Rössner, S., Van Gaal, L., Rissanen, A., Niskanen, L., Al Hakim, M., Madsen, J., Rasmussen, M. F., & Lean, M. E. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61375-1 · Cited by 1,163
Addressing Current Criticism Regarding the Value of Self-Report Dietary Data
Subar, A. F., Freedman, L. S., Tooze, J. A., Kirkpatrick, S. I., Boushey, C., Neuhouser, M. L., Thompson, F. E., Potischman, N., Guenther, P. M., Tarasuk, V., et al. (2015) · The Journal of Nutrition · doi:10.3945/jn.115.219634 · Cited by 1,047
Assessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
de la Sierra, A., Segura, J., Banegas, J. R., Gorostidi, M., de la Cruz, J. J., Armario, P., Oliveras, A., & Ruilope, L. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.168948 · Cited by 809
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
Diabetes and hypertension: a position statement by the American Diabetes Association
de Boer, I. H., Bangalore, S., Benetos, A., Davis, A. M., Michos, E. D., Muntner, P., Rossing, P., Zoungas, S., & Bakris, G. (2017) · Diabetes Care · doi:10.2337/dci17-0026 · Cited by 714
Predictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597
Salt Sensitivity of Blood Pressure: A Scientific Statement From the American Heart Association
Elijovich, F., Weinberger, M. H., Anderson, C. A. M., Appel, L. J., Bursztyn, M., Cook, N. R., Dart, R. A., Newton-Cheh, C. H., Sacks, F. M., & Laffer, C. L. (2016) · Hypertension · doi:10.1161/hyp.0000000000000047 · Cited by 482
Self-citationChung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Social jetlag, chronotype, and cardiometabolic risk
Wong, P. M., Hasler, B. P., Kamarck, T. W., Muldoon, M. F., & Manuck, S. B. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-2923 · Cited by 444
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Effects of Low-Carbohydrate and Low-Fat Diets: A Randomized Trial
Bazzano, L. A., Hu, T., Reynolds, K., Yao, L., Bunol, C., Liu, Y., Chen, C.-S., Klag, M. J., Whelton, P. K., & He, J. (2014) · Annals of Internal Medicine · doi:10.7326/m14-0180 · Cited by 346
Licht, C. M. M., de Geus, E. J. C., Seldenrijk, A., van Hout, H. P. J., Zitman, F. G., van Dyck, R., & Penninx, B. W. J. H. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.126698 · Cited by 319
SOMANZ guidelines for the management of hypertensive disorders of pregnancy 2014
Lowe, S. A., Bowyer, L., Lust, K., McMahon, L. P., Morton, M., North, R. A., Paech, M., & Said, J. M. (2015) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/ajo.12399 · Cited by 299
Nocturnal Hypertension: New Technology and Evidence
Kario, K. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.10971 · Cited by 298
Accuracy of Cuff-Measured Blood Pressure
Picone, D. S., Schultz, M. G., Otahal, P., Aakhus, S., Al-Jumaily, A. M., Black, J. A., Bos, W. J., Chambers, J. B., Chen, C.-H., Cheng, H.-M., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.05.064 · Cited by 277
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Racism and hypertension: a review of the empirical evidence and implications for clinical practice
Brondolo, E., Love, E. E., Pencille, M., Schoenthaler, A., & Ogedegbe, G. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.9 · Cited by 232
Nocturnal blood pressure and cardiovascular disease: a review of recent advances
Yano, Y., & Kario, K. (2012) · Hypertension Research · doi:10.1038/hr.2012.26 · Cited by 227
Power, M. C., Weuve, J., Gagne, J. J., McQueen, M. B., Viswanathan, A., & Blacker, D. (2011) · Epidemiology · doi:10.1097/ede.0b013e31822708b5 · Cited by 213
Frias, J., Virdi, N., Raja, P., Kim, Y., Savage, G., & Osterberg, L. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.7833 · Cited by 213
Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research
Muntner, P., Einhorn, P. T., Cushman, W. C., Whelton, P. K., Bello, N. A., Drawz, P. E., Green, B. B., Jones, D. W., Juraschek, S. P., Margolis, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.069 · Cited by 199
Self-citationOscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Berra, E., Azizi, M., Capron, A., Høieggen, A., Rabbia, F., Kjeldsen, S. E., Staessen, J. A., Wallemacq, P., & Persu, A. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07464 · Cited by 195
Davis, C. R., Hodgson, J. M., Woodman, R., Bryan, J., Wilson, C., & Murphy, K. J. (2017) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.116.146803 · Cited by 191
Agarwal, R., & Andersen, M. J. (2006) · Kidney International · doi:10.1038/sj.ki.5000081 · Cited by 184
Kario, K., Kanegae, H., Tomitani, N., Okawara, Y., Fujiwara, T., Yano, Y., Hoshide, S., & on behalf of the J-HOP Study Group (2019) · Hypertension · doi:10.1161/hypertensionaha.118.12740 · Cited by 167
Khamdaeng, T., Luo, J., Vappou, J., Terdtoon, P., & Konofagou, E. E. (2012) · Ultrasonics · doi:10.1016/j.ultras.2011.09.006 · Cited by 156
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
Willard-Grace, R., Chen, E. H., Hessler, D., DeVore, D., Prado, C., Bodenheimer, T., & Thom, D. H. (2015) · The Annals of Family Medicine · doi:10.1370/afm.1768 · Cited by 143
Beetroot supplementation lowers daily systolic blood pressure in older, overweight subjects
Jajja, A., Sutyarjoko, A., Lara, J., Rennie, K., Brandt, K., Qadir, O., & Siervo, M. (2014) · Nutrition Research · doi:10.1016/j.nutres.2014.09.007 · Cited by 138
Chase, N. L., Sui, X., Lee, D.-C., & Blair, S. N. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2009.6 · Cited by 143
Sharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002246 · Cited by 139
Exercise blood pressure: Clinical relevance and correct measurement
Sharman, J. E., & LaGerche, A. (2015) · Journal of Human Hypertension · doi:10.1038/jhh.2014.84 · Cited by 142
Limitations of GCTA as a solution to the missing heritability problem.
Krishna Kumar, S., Feldman, M. W., Rehkopf, D. H., & Tuljapurkar, S. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1520109113 · Cited by 128
DSM-5: a collection of psychiatrist views on the changes, controversies, and future directions
Nemeroff, C. B., Weinberger, D., Rutter, M., MacMillan, H. L., Bryant, R. A., Wessely, S., Stein, D. J., Pariante, C. M., Seemüller, F., Berk, M., et al. (2013) · BMC Medicine · doi:10.1186/1741-7015-11-202 · Cited by 128
Home Blood Pressure Monitoring in CKD
Andersen, M. J., Khawandi, W., & Agarwal, R. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.02.015 · Cited by 123
Niiranen, T. J., Asayama, K., Thijs, L., Johansson, J. K., Ohkubo, T., Kikuya, M., Boggia, J., Hozawa, A., Sandoya, E., Stergiou, G. S., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00100 · Cited by 120
Timing of Blood Pressure Measurement Related to Caffeine Consumption
Mort, J. R., & Kruse, H. R. (2008) · Annals of Pharmacotherapy · doi:10.1345/aph.1k337 · Cited by 98
A comparison of objective physical performance tests and future mortality in the elderly people
Veronese, N., Stubbs, B., Fontana, L., Trevisan, C., Bolzetta, F., Rui, M. D., Sartori, L., Musacchio, E., Zambon, S., Maggi, S., et al. (2016) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glw139 · Cited by 90
Stuebner, E., Vichayanrat, E., Low, D. A., Mathias, C. J., Isenmann, S., & Haensch, C.-A. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00049 · Cited by 84
Scott, J. A., Coombes, J. S., Prins, J. B., Leano, R. L., Marwick, T. H., & Sharman, J. E. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.166 · Cited by 82
Bruining, N., Caiani, E., Chronaki, C., Guzik, P., & van der Velde, E. (2014) · European Journal of Preventive Cardiology · doi:10.1177/2047487314552604 · Cited by 81
Perez, A. D., Dufault, S. M., Spears, E. C., Chae, D. H., Woods-Giscombe, C. L., & Allen, A. M. (2023) · Social Science & Medicine · doi:10.1016/j.socscimed.2022.115070 · Cited by 76
Momeni, J., Omidi, A., Raygan, F., & Akbari, H. (2016) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2016.07.007 · Cited by 71
Stergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74
Martínez-García, M.-A., Navarro-Soriano, C., Torres, G., Barbé, F., Caballero-Eraso, C., Lloberes, P., Diaz-Cambriles, T., Somoza, M., Masa, J. F., González, M., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11170 · Cited by 74
Optimal Schedule for Home Blood Pressure Measurement Based on Prognostic Data: The Finn-Home Study
Niiranen, T. J., Johansson, J. K., Reunanen, A., & Jula, A. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.162123 · Cited by 71
Ethnic differences regarding arterial stiffness of 6‐8‐year-old black and white boys
Mokwatsi, G. G., Schutte, A. E., & Kruger, R. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001267 · Cited by 62
Muntner, P., Carey, R. M., Jamerson, K., Wright, J. T., & Whelton, P. K. (2019) · Hypertension · doi:10.1161/hypertensionaha.118.11946 · Cited by 62
Telemonitoring at scale for hypertension in primary care: An implementation study
Hammersley, V., Parker, R., Paterson, M., Hanley, J., Pinnock, H., Padfield, P., Stoddart, A., Park, H. G., Sheikh, A., & McKinstry, B. (2020) · PLOS Medicine · doi:10.1371/journal.pmed.1003124 · Cited by 61
“2 million appointments in 2018 were taken up solely for hypertension checks [6], despite evidence that home monitoring is a better predictor of long-term outcomes than office measurement [7].”
Long‐Term Blood Pressure Variability and Risk of Cognitive Decline and Dementia Among Older Adults
Ernst, M. E., Ryan, J., Chowdhury, E. K., Margolis, K. L., Beilin, L. J., Reid, C. M., Nelson, M. R., Woods, R. L., Shah, R. C., Orchard, S. G., et al. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.120.019613 · Cited by 55
Amoore, J. N., Lemesre, Y., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f06ec7 · Cited by 56
How to check whether a blood pressure monitor has been properly validated for accuracy
Picone, D. S., Padwal, R., Campbell, N. R. C., Boutouyrie, P., Brady, T. M., Olsen, M. H., Delles, C., Lombardi, C., Mahmud, A., Meng, Y., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.14065 · Cited by 52
Mindfulness‐Based Stress Reduction in Women with Overweight or Obesity: A Randomized Clinical Trial
Raja‐Khan, N., Agito, K., Shah, J., Stetter, C. M., Gustafson, T. S., Socolow, H., Kunselman, A. R., Reibel, D. K., & Legro, R. S. (2017) · Obesity · doi:10.1002/oby.21910 · Cited by 53
Barriers to accurate blood pressure measurement in the medical office
Hwang, K. O., Aigbe, A., Ju, H.-H., Jackson, V. C., & Sedlock, E. W. (2018) · Journal of Primary Care & Community Health · doi:10.1177/2150132718816929 · Cited by 53
Dorresteijn, J. A. N., Schrover, I. M., Visseren, F. L. J., Scheffer, P. G., Oey, P. L., Danser, A. H. (., & Spiering, W. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835b6c02 · Cited by 50
Carter, B. L., Levy, B., Gryzlak, B., Xu, Y., Chrischilles, E., Dawson, J., Vander Weg, M., Christensen, A., James, P., & Polgreen, L. (2018) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.117.004188 · Cited by 46
Taylor, K. S., Heneghan, C. J., Stevens, R. J., Adams, E. C., Nunan, D., & Ward, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0126375 · Cited by 48
Severin, R., Sabbahi, A., Albarrati, A., Phillips, S. A., & Arena, S. (2020) · Physical Therapy · doi:10.1093/ptj/pzaa034 · Cited by 43
Bilo, G., Sala, O., Perego, C., Faini, A., Gao, L., Głuszewska, A., Ochoa, J. E., Pellegrini, D., Lonati, L. M., & Parati, G. (2017) · Hypertension Research · doi:10.1038/hr.2016.184 · Cited by 43
Gelecek, N., İlçin, N., Subaşi, S. S., Acar, S., Demir, N., & Örmen, M. (2012) · Health Care for Women International · doi:10.1080/07399332.2011.645960 · Cited by 39
Fuchs, S. C., Ferreira-da-silva, A. L., Moreira, L. B., Neyeloff, J. L., Fuchs, F. C., Gus, M., Wiehe, M., & Fuchs, F. D. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834e5a4f · Cited by 36
Nisenbaum, M. G., Melo, N. R. D., Giribela, C. R. G., Morais, T. L. D., Guerra, G. M., de Angelis, K., Mostarda, C., Baracat, E. C., & Consolim-Colombo, F. M. (2014) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2014.01.006 · Cited by 37
Cigarette smoking worsens systemic inflammation in persons with metabolic syndrome
Jamal, O., Aneni, E. C., Shaharyar, S., Ali, S. S., Parris, D., McEvoy, J. W., Veledar, E., Blaha, M. J., Blumenthal, R. S., Agatston, A. S., et al. (2014) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-6-79 · Cited by 30
“Blood pressure (BP) was measured using a calibrated aneroid sphygmomanometer after at least 5 minutes rest and according to guidelines from the American Heart Association [18].”
MethodLos, E., Quezada, E., Chen, Z., Lapidus, J., & Silberbach, M. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.07065 · Cited by 30
Sakhuja, S., Jaeger, B. C., Akinyelure, O. P., Bress, A. P., Shimbo, D., Schwartz, J. E., Hardy, S. T., Howard, G., Drawz, P., & Muntner, P. (2022) · The Journal of Clinical Hypertension · doi:10.1111/jch.14418 · Cited by 28
Schultz, M. G., Currie, K. D., Hedman, K., Climie, R. E., Maiorana, A., Coombes, J. S., & Sharman, J. E. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19052819 · Cited by 27
Aguiar, A. F., Balvedi, M. C. W., Buzzachera, C. F., Altimari, L. R., Lozovoy, M. A. B., Bigliassi, M., Januário, R. S. B., Pereira, R. M., Sanches, V. C., da Silva, D. K., et al. (2016) · European Journal of Nutrition · doi:10.1007/s00394-015-1019-6 · Cited by 21
Valera, B., Suhas, E., Counil, E., Poirier, P., & Dewailly, E. (2014) · Journal of the American College of Nutrition · doi:10.1080/07315724.2013.874913 · Cited by 21
Xie, F., Xu, J., Xia, L.-L., Luo, X., Jiang, Z., Wu, Y., & Su, H. (2020) · Hypertension Research · doi:10.1038/s41440-019-0386-4 · Cited by 21
Stergiou, G. S., Lourida, P., & Tzamouranis, D. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2010.107 · Cited by 18
Halm, M. A. (2014) · American Journal of Critical Care · doi:10.4037/ajcc2014364 · Cited by 15
Nilsen, R., Pripp, A. H., Høstmark, A. T., Haug, A., & Skeie, S. (2016) · Food & Nutrition Research · doi:10.3402/fnr.v60.32017 · Cited by 8
Measurements of arterial pressure and flow in vivo
Sharman, J. E., Segers, P., & Chirinos, J. A. (2022) · Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease · doi:10.1016/b978-0-323-91391-1.00002-9 · Cited by 3
Metadata
- Authors
- Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J.
- ORCID
- Venue
- Hypertension
- Published
- 2005-01
- Volume
- 45
- Issue
- 1
- Pages
- 142-161
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2160801689
- Semantic Scholar
- cc608ac67b0966145e814f721be04e1b0f95eeb3
- Cited by
- 2,051
- References
- 226
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 48 · 2023: 61 · 2022: 79 · 2021: 77 · 2020: 101 · 2019: 85 · 2018: 113 · 2017: 144 · 2016: 166 · 2015: 161 · 2014: 104 · 2013: 114 · 2012: 133
- FWCI
- 39.42
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- blood pressure measurement, auscultatory method, Korotkoff sounds, mercury sphygmomanometer, aneroid sphygmomanometer, oscillometric method, home blood pressure monitoring, ambulatory blood pressure monitoring, white coat hypertension, cuff size, observer training, pregnant women, laboratory animals, hypertension risk prediction
- MeSH terms
- Adult, Aged, Animals, Auscultation, Automation, Blood Pressure Determination, Calibration, Cardiovascular Diseases, Child, Circadian Rhythm, Clinical Competence, Diagnostic Errors, Equipment Design, Female, Humans, Hypertension, Male, Middle Aged, Obesity, Organ Specificity, Oscillometry, Posture, Predictive Value of Tests, Pregnancy, Self Care, Stress, Psychological, Blood Pressure Monitors, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review