The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical properties
Abstract
When a picosecond light pulse is incident on biological tissue, the temporal characteristics of the light backscattered from, or transmitted through, the sample carry information about the optical absorption and scattering coefficients of the tissue. We develop a simple model, based on the diffusion approximation to radiative transfer theory, which yields analytic expressions for the pulse shape in terms of the interaction coefficients of a homogeneous slab. The model predictions are in good agreement with the results of preliminary in vivo experiments and Monte Carlo simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stochastic Problems in Physics and Astronomy
Chandrasekhar, S. (1943) · Reviews of Modern Physics · doi:10.1103/revmodphys.15.1 · Cited by 8,470
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Scattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
Model for photon migration in turbid biological media
Bonner, R. F., Nossal, R., Havlin, S., & Weiss, G. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000423 · Cited by 376
The physics of photodynamic therapy
Wilson, B. C., & Patterson, M. S. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/4/001 · Cited by 338
Self-citationTime-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329
Self-citationModeling optical and thermal distributions in tissue during laser irradiation
Jacques, S. L., & Prahl, S. A. (1987) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900060604 · Cited by 259
Cited by
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Polymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
Determining the optical properties of turbid media by using the adding–doubling method
Prahl, S. A., van Gemert, M. J. C., & Welch, A. J. (1993) · Applied Optics · doi:10.1364/ao.32.000559 · Cited by 931
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Self-citationSpectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationMolecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Imaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
Non-Invasive In Vivo Characterization of Breast Tumors Using Photon Migration Spectroscopy
Tromberg, B. J., Shah, N., Lanning, R., Cerussi, A., Espinoza, J., Pham, T., Svaasand, L., & Butler, J. (2000) · Neoplasia · doi:10.1038/sj.neo.7900082 · Cited by 687
Quantitation and mapping of tissue optical properties using modulated imaging
Cuccia, D. J., Bevilacqua, F., Durkin, A. J., Ayers, F. R., & Tromberg, B. J. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3088140 · Cited by 655
Light fields in complex media: Mesoscopic scattering meets wave control
Rotter, S., & Gigan, S. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.015005 · Cited by 654
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Image-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation
Gioux, S., Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00034 · Cited by 599
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Self-citationFluorescence Spectroscopy In Vivo
Ramanujam, N. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0102 · Cited by 508
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Optical imaging in medicine: II. Modelling and reconstruction
Arridge, S. R., & Hebden, J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/008 · Cited by 495
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Self-citationKienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Self-citationMeasurement of the penetration depths of red and near infrared light in human “ex vivo” tissues
Stolik, S., Delgado, J. A., Pérez, A., & Anasagasti, L. (2000) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/s1011-1344(00)00082-8 · Cited by 468
Time domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Double-integrating-sphere system for measuring the optical properties of tissue
Pickering, J. W., Prahl, S. A., van Wieringen, N., Beek, J. F., Sterenborg, H. J. C. M., & van Gemert, M. J. C. (1993) · Applied Optics · doi:10.1364/ao.32.000399 · Cited by 461
Contini, D., Martelli, F., & Zaccanti, G. (1997) · Applied Optics · doi:10.1364/ao.36.004587 · Cited by 460
The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics
Boas, D. A., Gaudette, T., Strangman, G., Cheng, X., Marota, J. J. A., & Mandeville, J. B. (2001) · NeuroImage · doi:10.1006/nimg.2000.0674 · Cited by 459
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Optical reflectance and transmittance of tissues: principles and applications
Wilson, B. C., & Jacques, S. L. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64355 · Cited by 421
Self-citationCulver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Alerstam, E., Svensson, T., & Andersson-Engels, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041496 · Cited by 407
A submillimeter resolution fluorescence molecular imaging system for small animal imaging
Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2003) · Medical Physics · doi:10.1118/1.1568977 · Cited by 390
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
Sevick, E. M., Chance, B., Leigh, J., Nioka, S., & Maris, M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90339-u · Cited by 360
Self-citationTutorial on diffuse light transport
Jacques, S. L., & Pogue, B. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2967535 · Cited by 354
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Hielscher, A. H., Alcouffe, R. E., & Barbour, R. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/5/017 · Cited by 332
Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry
Fantini, S. (1995) · Optical Engineering · doi:10.1117/12.183988 · Cited by 330
MRI-Guided Diffuse Optical Spectroscopy of Malignant and Benign Breast Lesions
Ntziachristos, V., Yodh, A. G., Schnall, M. D., & Chance, B. (2002) · Neoplasia · doi:10.1038/sj.neo.7900244 · Cited by 321
Self-citationSources of Absorption and Scattering Contrast for Near-Infrared Optical Mammography
Cerussi, A. E., Berger, A. J., Bevilacqua, F., Shah, N., Jakubowski, D., Butler, J., Holcombe, R. F., & Tromberg, B. J. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80529-9 · Cited by 295
Noninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 294
Self-citationA solid tissue phantom for photon migration studies
Cubeddu, R., Pifferi, A., Taroni, P., Torricelli, A., & Valentini, G. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/011 · Cited by 289
Bevilacqua, F., Berger, A. J., Cerussi, A. E., Jakubowski, D., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.006498 · Cited by 284
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
van Veen, R. L. P., Sterenborg, H. J. C. M., Pifferi, A., Torricelli, A., Chikoidze, E., & Cubeddu, R. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2085149 · Cited by 276
Al-Rawi, P. G., Smielewski, P., & Kirkpatrick, P. J. (2001) · Stroke · doi:10.1161/hs1101.098356 · Cited by 273
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Diffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Optical Image-Guided Cancer Surgery: Challenges and Limitations
Keereweer, S., Van Driel, P. B. A. A., Snoeks, T. J. A., Kerrebijn, J. D. F., Baatenburg de Jong, R. J., Vahrmeijer, A. L., Sterenborg, H. J. C. M., & Löwik, C. W. G. M. (2013) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-12-3598 · Cited by 270
Strangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 262
Determining changes in NIR absorption using a layered model of the human head
Steinbrink, J., Wabnitz, H., Obrig, H., Villringer, A., & Rinneberg, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/320 · Cited by 259
Fantini, S., Franceschini, M. A., Fishkin, J. B., Barbieri, B., & Gratton, E. (1994) · Applied Optics · doi:10.1364/ao.33.005204 · Cited by 259
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Chin, L. M. K., Kowalchuk, J. M., Barstow, T. J., Kondo, N., Amano, T., Shiojiri, T., & Koga, S. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01216.2010 · Cited by 106
“A time-correlated single-photon counting board (constant fraction discriminators, time-to-amplitude converters, A/D converters, and histogram memories) acquires timeresolved reflectance curves of the emerging photons, and estimation of the optical path length, reduced scattering coefficient ( s=) and absorption coeffi…”
MethodQuantification of ischemic muscle deoxygenation by near infrared time-resolved spectroscopy
Hamaoka, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Sako, T., Higuchi, H., Kurosawa, Y., Shimomitsu, T., Miwa, M., et al. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429975 · Cited by 97
Self-citationHiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0644-y · Cited by 69
Jones, B., Dat, M., & Cooper, C. E. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.12.127002 · Cited by 37
Niemeijer, V. M., Spee, R. F., Jansen, J. P., Buskermolen, A. B. C., van Dijk, T., Wijn, P. F. F., & Kemps, H. M. C. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12269 · Cited by 33
“…photon diffusion theory, an absolute measure of tissue oxygen saturation (TSI, which equals [O2Hb]/([O2Hb] + [HHb]) 9 100) can be calculated from the absorption coefficients derived from the slopes of light attenuation at different source-detector distances and wavelengths (Patterson et al., 1989).”
BackgroundComparing Diffusion Approximation with Radiation Transfer Analysis for Light Transport in Tissues
Guo, Z., Wan, S. K., Kim, K., & Kosaraju, C. (2003) · Optical Review · doi:10.1007/s10043-003-0415-y · Cited by 27
van Hooff, M., Meijer, E. J., Scheltinga, M. R. M., Savelberg, H. H. C. M., & Schep, G. (2022) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12738 · Cited by 20
Horiuchi, M., Endo, J., Dobashi, S., Handa, Y., Kiuchi, M., & Koyama, K. (2017) · Physiological Reports · doi:10.14814/phy2.13475 · Cited by 19
“It has been reported that NIRS signals can reach half the depth of the distance between the probe and detector (Patterson et al. 1989).”
BackgroundWalking economy at simulated high altitude in human healthy young male lowlanders
Horiuchi, M., Handa, Y., Abe, D., & Fukuoka, Y. (2016) · Biology Open · doi:10.1242/bio.019810 · Cited by 16
Metadata
- Authors
- Patterson, M. S., Chance, B., & Wilson, B. C.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1989-06-15
- Volume
- 28
- Issue
- 12
- Pages
- 2331
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2050973816
- Cited by
- 2,087
- References
- 13
- FWCI
- 19.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.