The DOI matches its Crossref record; 110 of the 110 references it cites were found in a registry or an index.
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Open accessAbstract
### Introduction Technological advances in neural interfaces are providing increasingly more powerful “toolkits” of designs, materials, components, and integrated devices for establishing high-fidelity chronic neural interfaces. For a broad class of neuroscience studies, the primary
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Interneurons of the hippocampus
Freund, T. F., & Buzsáki, G. (1998) · Hippocampus · doi:10.1002/(sici)1098-1063(1996)6:4<347::aid-hipo1>3.0.co;2-i · Cited by 3,441
Self-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 4×
“…activity from neurons recorded within the brain (Georgopoulos et al., 1986; Serruya et al., 2002; Taylor et al., 2002; Shenoy et al., 2003; Andersen et al., 2004; Musallam et al., 2004; Lebedev et al., 2005; Hochberg et al., 2006; Santhanam et al., 2006; Lee et al., 2008; Velliste et al., 2008).”
BackgroundInfluentialFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationDynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Neuronal Diversity and Temporal Dynamics: The Unity of Hippocampal Circuit Operations
Klausberger, T., & Somogyi, P. (2008) · Science · doi:10.1126/science.1149381 · Cited by 2,050
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · cited 3×
“1E) (McNaughton et al., 1983; Hoffman and McNaughton, 2002; Csicsvari et al., 2003; Barthó et al., 2004; Buzsáki, 2004).”
MethodSelf-citationLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“Most BCI systems typically allow neural activity to control computer cursors or external devices (Wolpaw et al., 2002; Carmena et al., 2003; Hochberg et al., 2006; Velliste et al., 2008).”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 2×
“…(Farwell and Donchin, 1988; Wolpaw et al., 1991; Sutter, 1992; McFarland et al., 1993, 2008; Pfurtscheller et al., 1993, 2000; Wolpaw and McFarland, 1994, 2004; Birbaumer et al., 1999; Millán et al., 2004; Kübler et al., 2005; Blankertz et al., 2006; Vaughan et al., 2006; Müller et al., 2008).”
MethodDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Electrical inhibition of pain by stimulation of the dorsal columns: preliminary clinical report.
Shealy, C. N., Mortimer, J. T., & RESWICK, J. B. (1990) · PubMed · Cited by 1,237
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Self-citationBunge, R. G., Keettel, W. C., & Sherman, J. K. (1954) · Fertility and Sterility · doi:10.1016/s0015-0282(16)31802-7 · Cited by 1,176
Harris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Self-citationAn EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Crone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Electrical Inhibition of Pain by Stimulation of the Dorsal Columns: Preliminary Clinical Report
SHEALY, C. N., MORTIMER, J. T., & RESWICK, J. B. (1967) · Anesthesia & Analgesia · doi:10.1213/00000539-196707000-00025 · Cited by 1,016
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Self-citationBarthó, P., Hirase, H., Monconduit, L., Zugaro, M., Harris, K. D., & Buzsáki, G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01170.2003 · Cited by 887
Self-citationChronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Noninvasive Brain-Actuated Control of a Mobile Robot by Human EEG
del R. Millan, J., Renkens, F., Mourino, J., & Gerstner, W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827086 · Cited by 740
Spectral Changes in Cortical Surface Potentials during Motor Movement
Miller, K. J., Leuthardt, E. C., Schalk, G., Rao, R. P. N., Anderson, N. R., Moran, D. W., Miller, J. W., & Ojemann, J. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3886-06.2007 · Cited by 738
Self-citationA high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Behavior-dependent short-term assembly dynamics in the medial prefrontal cortex
Fujisawa, S., Amarasingham, A., Harrison, M. T., & Buzsáki, G. (2008) · Nature Neuroscience · doi:10.1038/nn.2134 · Cited by 695
Self-citationStaba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666
Differential attention-dependent response modulation across cell classes in macaque visual area V4
Mitchell, J. F., Sundberg, K. A., & Reynolds, J. H. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.018 · Cited by 665
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 2×
“…activity from neurons recorded within the brain (Georgopoulos et al., 1986; Serruya et al., 2002; Taylor et al., 2002; Shenoy et al., 2003; Andersen et al., 2004; Musallam et al., 2004; Lebedev et al., 2005; Hochberg et al., 2006; Santhanam et al., 2006; Lee et al., 2008; Velliste et al., 2008).”
BackgroundWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 2×
“Proof of concept for obtaining high-quality unit recordings for more than several months has been established through independent studies from several labs that collectively cover diverse types of microelectrode arrays implanted in rat, cat, and nonhuman primate (Rousche and Normann, 1998; Liu et al., 1999; Kipke et a…”
BackgroundLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citationMcNaughton, B. L., O'Keefe, J., & Barnes, C. A. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90097-3 · Cited by 567
Patients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
Self-citationDecoding two-dimensional movement trajectories using electrocorticographic signals in humans
Schalk, G., Kubánek, J., Miller, K. J., Anderson, N. R., Leuthardt, E. C., Ojemann, J. G., Limbrick, D., Moran, D., Gerhardt, L. A., & Wolpaw, J. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/012 · Cited by 527
Self-citationCurrent trends in Graz brain-computer interface (BCI) research
Pfurtscheller, G., Neuper, C., Guger, C., Harkam, W., Ramoser, H., Schlogl, A., Obermaier, B., & Pregenzer, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847821 · Cited by 518
Brain-Computer Interface—a new communication device for handicapped persons
Pfurtscheller, G., Flotzinger, D., & Kalcher, J. (1993) · Journal of Microcomputer Applications · doi:10.1006/jmca.1993.1030 · Cited by 502
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Self-citationMüller, K.-R., Tangermann, M., Dornhege, G., Krauledat, M., Curio, G., & Blankertz, B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.022 · Cited by 474
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · cited 1×
“1D) (Seymour and Kipke, 2007), materials (Ludwig et al., 2006; Abidian and Martin, 2008), approaches to mitigate chronic reactive tissue responses (Shain et al., 2003; Spataro et al., 2005), and minimally damaging insertion techniques (Bjornsson et al., 2006; Johnson et al., 2007) are being…”
BackgroundSelf-citationLong-term motor cortex plasticity induced by an electronic neural implant
Jackson, A., Mavoori, J., & Fetz, E. E. (2006) · Nature · doi:10.1038/nature05226 · Cited by 450
Self-citationMultichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
Inference of hand movements from local field potentials in monkey motor cortex
Mehring, C., Rickert, J., Vaadia, E., de Oliveira, S. C., Aertsen, A., & Rotter, S. (2003) · Nature Neuroscience · doi:10.1038/nn1158 · Cited by 435
Coordinated Reactivation of Distributed Memory Traces in Primate Neocortex
Hoffman, K. L., & McNaughton, B. L. (2002) · Science · doi:10.1126/science.1073538 · Cited by 420
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 2×
“Proof of concept for obtaining high-quality unit recordings for more than several months has been established through independent studies from several labs that collectively cover diverse types of microelectrode arrays implanted in rat, cat, and nonhuman primate (Rousche and Normann, 1998; Liu et al., 1999; Kipke et a…”
BackgroundMassively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationTemporal Interaction between Single Spikes and Complex Spike Bursts in Hippocampal Pyramidal Cells
Harris, K. D., Hirase, H., Leinekugel, X., Henze, D. A., & Buzsáki, G. (2001) · Neuron · doi:10.1016/s0896-6273(01)00447-0 · Cited by 388
Self-citationSpatial spectra of scalp EEG and EMG from awake humans
Freeman, W. J., Holmes, M. D., Burke, B. C., & Vanhatalo, S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00045-2 · Cited by 370
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Self-citationSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Abidian, M. R., & Martin, D. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.022 · Cited by 338
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
Self-citationThe Berlin brain-computer interface: EEG-based communication without subject training
Blankertz, B., Dornhege, G., Krauledat, M., Muller, K.-R., Kunzmann, V., Losch, F., & Curio, G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875557 · Cited by 332
Prediction of arm movement trajectories from ECoG-recordings in humans
Pistohl, T., Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.10.001 · Cited by 331
Bjornsson, C. S., Oh, S. J., Al-Kofahi, Y. A., Lim, Y. J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330
Self-citationRickert, J., de Oliveira, S. C., Vaadia, E., Aertsen, A., Rotter, S., & Mehring, C. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.0816-05.2005 · Cited by 316
Visualization of significant ERD/ERS patterns in multichannel EEG and ECoG data
Graimann, B., Huggins, J. E., Levine, S. P., & Pfurtscheller, G. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00697-6 · Cited by 302
Lebedev, M. A., Carmena, J. M., O'Doherty, J. E., Zacksenhouse, M., Henriquez, C. S., Principe, J. C., & Nicolelis, M. A. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4088-04.2005 · Cited by 290
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 271
Electrocorticographic high gamma activity versus electrical cortical stimulation mapping of naming
Sinai, A., Bowers, C. W., Crainiceanu, C. M., Boatman, D., Gordon, B., Lesser, R. P., Lenz, F. A., & Crone, N. E. (2005) · Brain · doi:10.1093/brain/awh491 · Cited by 266
Shain, W., Spataro, L., Dilgen, J., Haverstick, K., Retterer, S., Isaacson, M., Saltzman, M., & Turner, J. N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814800 · Cited by 227
Self-citationSpataro, L., Dilgen, J., Retterer, S., Spence, A. J., Isaacson, M., Turner, J. N., & Shain, W. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215
Self-citationEmulation of computer mouse control with a noninvasive brain–computer interface
McFarland, D. J., Krusienski, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/001 · Cited by 202
Neural prosthetic control signals from plan activity
Shenoy, K. V., Meeker, D., Cao, S., Kureshi, S. A., Pesaran, B., Buneo, C. A., Batista, A. P., Mitra, P. P., Burdick, J. W., & Andersen, R. A. (2003) · NeuroReport · doi:10.1097/00001756-200303240-00013 · Cited by 191
Increased gamma-range activity in human sensorimotor cortex during performance of visuomotor tasks
Aoki, F., Fetz, E. E., Shupe, L., Lettich, E., & Ojemann, G. A. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00064-9 · Cited by 177
Self-citationCompact Movable Microwire Array for Long-Term Chronic Unit Recording in Cerebral Cortex of Primates
Jackson, A., & Fetz, E. E. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00569.2007 · Cited by 173
Self-citationMicropower Circuits for Bidirectional Wireless Telemetry in Neural Recording Applications
Neihart, N. M., & Harrison, R. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856247 · Cited by 172
ECoG factors underlying multimodal control of a brain-computer interface
Wilson, J. A., Felton, E. A., Garell, P. C., Schalk, G., & Williams, J. C. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875570 · Cited by 163
Self-citationFelton, E. A., Wilson, J. A., Williams, J. C., & Garell, P. C. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.3.495 · Cited by 162
Andersen, R. A., Burdick, J. W., Musallam, S., Pesaran, B., & Cham, J. G. (2004) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2004.09.009 · Cited by 155
HermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H. Y., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 152
A Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture
Ghovanloo, M., & Najafi, K. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903970 · Cited by 151
A floating metal microelectrode array for chronic implantation
Musallam, S., Bak, M. J., Troyk, P. R., & Andersen, R. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.005 · Cited by 149
Somadendritic Backpropagation of Action Potentials in Cortical Pyramidal Cells of the Awake Rat
Buzsáki, G., & Kandel, A. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.3.1587 · Cited by 149
Self-citationRestoring lost cognitive function.
Berger, T. W., Ahuja, A., Courellis, S. H., Deadwyler, S. A., Erinjippurath, G., Gerhardt, G. A., Gholmieh, G., Granacki, J. J., Hampson, R., Hsaio, M. C., et al. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511498 · Cited by 148
A Fully Integrated Mixed-Signal Neural Processor for Implantable Multichannel Cortical Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894986 · Cited by 148
Implantation of a Closed-Loop Stimulation in the Management of Medically Refractory Focal Epilepsy
Fountas, K. N., Smith, J. R., Murro, A. M., Politsky, J. M., Park, Y. D., & Jenkins, P. D. (2005) · Stereotactic and Functional Neurosurgery · doi:10.1159/000088656 · Cited by 139
The neurochip BCI: towards a neural prosthesis for upper limb function
Jackson, A., Moritz, C. T., Mavoori, J., Lucas, T. H., & Fetz, E. E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875547 · Cited by 139
Self-citationAn autonomous implantable computer for neural recording and stimulation in unrestrained primates
Mavoori, J., Jackson, A., Diorio, C., & Fetz, E. E. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.04.017 · Cited by 122
Self-citationAn EEG-based method for graded cursor control
McFarland, D. J., Neat, G. W., Read, R. F., & Wolpaw, J. R. (1993) · Psychobiology · doi:10.3758/bf03327130 · Cited by 120
Neurotrophic electrode: Method of assembly and implantation into human motor speech cortex
Bartels, J., Andreasen, D., Ehirim, P., Mao, H., Seibert, S., Wright, E. J., & Kennedy, P. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.030 · Cited by 108 · cited 2×
“A growing number of wire and microfabrication electrode technologies intended to meet these requirements are in various stages of development (McNaughton et al., 1983; Nordhausen et al., 1996; Hetke and Anderson, 2002; Nicolelis et al., 2003; Wise et al., 2004; Motta and Judy, 2005; Rennaker et al., 2005; McCreery et…”
BackgroundLeuthardt, E. C., Miller, K. J., Anderson, N., Schalk, G., Dowling, J. L., Miller, J. W., Moran, D. W., & Ojemann, J. G. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000255413.70807.6e · Cited by 101
Self-citationExtraction and localization of mesoscopic motor control signals for human ECoG neuroprosthetics
Sanchez, J. C., Gunduz, A., Carney, P. R., & Príncipe, J. C. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.04.019 · Cited by 100
Prevention of Mechanical Failures in Implanted Spinal Cord Stimulation Systems
Henderson, J. M., Schade, C. M., Sasaki, J., Caraway, D. L., & Oakley, J. C. (2006) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.2006.00059.x · Cited by 97
Self-citationMargalit, E., Weiland, J. D., Clatterbuck, R. E., Fujii, G. Y., Maia, M., Tameesh, M., Torres, G. F., D’Anna, S. A., Desai, S., Piyathaisere, D. V., et al. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00345-x · Cited by 96
Loeb, G. E., Walker, A. E., Uematsu, S., & Konigsmark, B. W. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110206 · Cited by 95
Spatiotemporal pH dynamics following insertion of neural microelectrode arrays
Johnson, M. D., Kao, O. E., & Kipke, D. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.023 · Cited by 93
Self-citationJackson, A., Mavoori, J., & Fetz, E. E. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00710.2006 · Cited by 92
Self-citationTissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 91
Microelectrode Array for Chronic Deep-Brain Microstimulation and Recording
McCreery, D. B., Lossinsky, A. S., Pikov, V., & Liu, X. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870215 · Cited by 79
Motta, P. S., & Judy, J. W. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845225 · Cited by 77
Oweiss, K. G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873749 · Cited by 77
Schalk, G. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/p01 · Cited by 73
Self-citationSong, Y., Patterson, W. R., Bull, C. W., Beals, J., Hwang, N.-J., Deangelis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Fellows, M. R., et al. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848337 · Cited by 71
Arrays for chronic functional microstimulation of the lumbosacral spinal cord
McCreery, D. B., Pikov, V., Lossinsky, A. S., Bullara, L. A., & Agnew, W. F. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827223 · Cited by 57
Toward Replacement Parts for the Brain
(2005) · The MIT Press eBooks · doi:10.7551/mitpress/6858.001.0001 · Cited by 54
Evaluation of Electrode Array Material for Neural Prostheses
Bullara, L. A., Agnew, W. F., Yuen, T. G. H., Jacques, S., & Pudenz, R. H. (1979) · Neurosurgery · doi:10.1227/00006123-197912000-00006 · Cited by 45
Lee, J., Rhew, H.-G., Kipke, D. R., & Flynn, M. (2008) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2008.4585958 · Cited by 42
Self-citationSong, Y., Patterson, W. R., Bull, C. W., Borton, D. A., Li, Y., Nurmikko, A. V., Simeral, J. D., & Donoghue, J. P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352319 · Cited by 40
Rennaker, R. L., Ruyle, A. M., Street, S. E., & Sloan, A. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.07.018 · Cited by 35
Silicon microelectrodes for extracellular recording
Hetke, J. F., & Anderson, D. (2002) · Biomedical engineering series · doi:10.1201/9781420040876.ch7 · Cited by 32
Self-citationThe electrical activity in the motor cortex that accompanies voluntary movement.
Gs, B., & Craggs, M. D. (1972) · PubMed · Cited by 25
Craggs, M. D. (1975) · PubMed · Cited by 23
Neves, H. P., & Ruther, P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353831 · Cited by 19
Research works printed but not linked: 4
- Moritz, 2008, Monkeys use cortical activity to control functional electrical stimulation of paralyzed muscles, Soc Neurosci Abstr, 34, 779
- Nadasdy Z Csicsvari J Penttonen M Buzsáki G (1998) in Neuronal ensembles: strategies for recording and decoding, Extracellular recording and analysis of electrical activity: from single cells to ensembles, eds Eichenbaum H Davis JL (Wiley, New York), Ed 1, pp 17–55.
- 10.3171/spi.2006.5.3.183 · doi:10.3171/spi.2006.5.3.183
- Schalk, 2007, Toward brain-computer interfacing using phonemes decoded from electrocorticography activity (ECoG) in humans, Soc Neurosci Abstr, 33, 414
Cited by
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Self-citationYang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Dimensionality reduction for large-scale neural recordings
Cunningham, J. P., & Yu, B. M. (2014) · Nature Neuroscience · doi:10.1038/nn.3776 · Cited by 1,219
In vivo recordings of brain activity using organic transistors
Khodagholy, D., Doublet, T., Quilichini, P., Gurfinkel, M., Leleux, P., Ghestem, A., Ismailova, E., Hervé, T., Sanaur, S., Bernard, C., et al. (2013) · Nature Communications · doi:10.1038/ncomms2573 · Cited by 1,012
Modelling and analysis of local field potentials for studying the function of cortical circuits
Einevoll, G. T., Kayser, C., Logothetis, N. K., & Panzeri, S. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3599 · Cited by 857
Metadata
- Authors
- Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2008-11-12
- Volume
- 28
- Issue
- 46
- Pages
- 11830-11838
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2092449645
- Cited by
- 286
- References
- 110
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.