Current state of digital signal processing in myoelectric interfaces and related applications
Open accessAbstract
This review discusses the critical issues and recommended practices from the perspective of myoelectric interfaces. The major benefits and challenges of myoelectric interfaces are evaluated. The article aims to fill gaps left by previous reviews and identify avenues for future research. Recommendations are given, for example, for electrode placement, sampling rate, segmentation, and classifiers. Four groups of applications where myoelectric interfaces have been adopted are identified: assistive technology, rehabilitation technology, input devices, and silent speech interfaces. The state-of-the-art applications in each of these groups are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 2012
Müller, A., Sejdinović, D., & Piechocki, R. J. (2012) · Cited by 1,027
Medical instrumentation: Application and design
Undar, A., Calhoon, J. H., & Rocha, A. D. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,015
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
2006 IEEE/Rsj International Conference on Intelligent Robots and Systems
(2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.282202 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
DLR-Hand II: next generation of a dextrous robot hand
Butterfass, J., Grebenstein, M., Liu, H., & Hirzinger, G. (2002) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.932538 · Cited by 808
Measurement of human muscle fatigue
Vøllestad, N. K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02251-6 · Cited by 796
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725
Shared and specific muscle synergies in natural motor behaviors
d'Avella, A., & Bizzi, E. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0500199102 · Cited by 707
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
EMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
A Framework for Hand Gesture Recognition Based on Accelerometer and EMG Sensors
Zhang, X., Chen, X., Li, Y., Lantz, V., Wang, K., & Yang, J. (2011) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/tsmca.2011.2116004 · Cited by 618
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Independent Component Analysis: A Tutorial Introduction
(2007) · Technometrics · doi:10.1198/004017007000000191 · Cited by 551
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
2022 International Conference on Robotics and Automation (ICRA)
(2022) · doi:10.1109/icra46639.2022 · Cited by 463
(2014) · IEEE Pulse · doi:10.1109/mpul.2014.2316040 · Cited by 456
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Atlas of Muscle Innervation Zones
Barbero, M., Merletti, R., & Rainoldi, A. (2012) · Springer eBooks · doi:10.1007/978-88-470-2463-2 · Cited by 419
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Resolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 402
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Evaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Fuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Bonato, P., D'Alessio, T., & Knaflitz, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661154 · Cited by 375
Influence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
Farina, D., & Merletti, R. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00025-0 · Cited by 367
Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Fehr, L., Langbein, W. E., & Skaar, S. B. (2000) · PubMed · Cited by 358
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Chu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352
A Novel Feature Extraction for Robust EMG Pattern Recognition
Phinyomark, A., Limsakul, C., & Phukpattaranont, P. (2009) · arXiv (Cornell University) · doi:10.48550/arxiv.0912.3973 · Cited by 351
Merletti, R., Botter, A., Troiano, A., Merlo, E., & Minetto, M. A. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.006 · Cited by 345
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
EMG/FORCE RELATIONS AND FATIGUE OF HUMAN VOLUNTARY CONTRACTIONS
Bigland-Ritchie, B. (1981) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198101000-00002 · Cited by 331
Kim, K. S., Choi, H. H., Moon, C. S., & Mun, C. W. (2011) · Current Applied Physics · doi:10.1016/j.cap.2010.11.051 · Cited by 331
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299
The Usefulness of Mean and Median Frequencies in Electromyography Analysis
Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges · doi:10.5772/50639 · Cited by 294
Long, J., Li, Y., Wang, H., Yu, T., Pan, J., & Li, F. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2197221 · Cited by 293
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Falla, D., Dall'Alba, P., Rainoldi, A., Merletti, R., & Jull, G. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00708-8 · Cited by 277
Hargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357138 · Cited by 275
29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
(2007) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.897780 · Cited by 271
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
EMG-Based Control of a Robot Arm Using Low-Dimensional Embeddings
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2039378 · Cited by 267
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260
Yang, X., Zhang, G., Lü, J., & Ma, J. (2010) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2010.2087382 · Cited by 260
Lucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2177662 · Cited by 251
Bilodeau, M., Schindler-Ivens, S., Williams, D. M., Chandran, R., & Sharma, S. S. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00050-0 · Cited by 249
Application of Wavelet Analysis in EMG Feature Extraction for Pattern Classification
Phinyomark, A., Limsakul, C., & Phukpattaranont, P. (2011) · Measurement Science Review · doi:10.2478/v10048-011-0009-y · Cited by 236
New perspectives on spinal motor systems
Bizzi, E., Tresch, M. C., Saltiel, P., & d'Avella, A. (2000) · Nature Reviews Neuroscience · doi:10.1038/35039000 · Cited by 230
Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm
Cavallaro, E. E., Rosen, J., Perry, J. C., & Burns, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880883 · Cited by 230
Minimizing Electrode Motion Artifact by Skin Abrasion
Tam, H., & Webster, J. G. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326117 · Cited by 220
Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287383 · Cited by 218
Hand gesture recognition and virtual game control based on 3D accelerometer and EMG sensors
Zhang, X., Chen, X., Wang, W.-H., Yang, J.-H., Lantz, V., & Wang, K.-Q. (2009) · Proceedings of the 14th international conference on Intelligent user interfaces · doi:10.1145/1502650.1502708 · Cited by 212
Prediction of handgrip forces using surface EMG of forearm muscles
Hoozemans, M. J. M., & van Dieën, J. H. (2005) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.09.001 · Cited by 211
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
2008 IEEE International Symposium on Industrial Electronics
Aimé, J., Roudet, J., Clavel, E., Aouine, O., Labarre, C., Costa, F., & Ecrabey, J. (2008) · doi:10.1109/isie12173.2008 · Cited by 202
A fuzzy clustering neural network architecture for multifunction upper-limb prosthesis
Karlik, B., Tokhi, M. O., & Alci, M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.818469 · Cited by 198
EMG pattern recognition based on artificial intelligence techniques
Park, S.-H., & Lee, S.-P. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736154 · Cited by 197
Stango, A., Negro, F., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2366752 · Cited by 191
High-density surface EMG maps from upper-arm and forearm muscles
Rojas-Martínez, M., Mañanas, M. A., & Alonso, J. F. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-85 · Cited by 181
Jiang, N., Vest-Nielsen, J. L., Muceli, S., & Farina, D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-42 · Cited by 181
Advances in Surface EMG: Recent Progress in Detection and Processing Techniques
Merletti, R., Aventaggiato, M., Botter, A., Holobar, A., Marateb, H., & Vieira, T. M. M. (2010) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v38.i4.10 · Cited by 176
Muceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172
Selective Classification for Improved Robustness of Myoelectric Control Under Nonideal Conditions
Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2113182 · Cited by 172
Wearable EMG-based HCI for Electric-Powered Wheelchair Users with Motor Disabilities
Moon, I., Lee, M., Chu, J., & Mun, M. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570513 · Cited by 171
Lorrain, T., Jiang, N., & Farina, D. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-25 · Cited by 165
2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)
(2004) · 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat No 04CH37566) IROS-04 · doi:10.1109/iros.2004.1389710 · Cited by 165
Stepp, C. E. (2012) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2011/11-0214 · Cited by 161
Examining the adverse effects of limb position on pattern recognition based myoelectric control
Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627638 · Cited by 161
Measurement of EMG activity with textile electrodes embedded into clothing
Finni, T., Hu, M., Kettunen, P., Vilavuo, T., & Cheng, S. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/007 · Cited by 160
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
Farrell, T. R., & Weir, R. F. F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923917 · Cited by 159
2015 IEEE International Conference on Rehabilitation Robotics (ICORR)
(2015) · doi:10.1109/icorr34445.2015 · Cited by 159
2007 International Conference on Mechatronics and Automation
(2007) · doi:10.1109/icma12434.2007 · Cited by 155
Towards the Control of Individual Fingers of a Prosthetic Hand Using Surface EMG Signals
Tenore, F. V., Ramos‐Murguialday, A., Fahmy, A., Acharya, S., Etienne‐Cummings, R., & Thakor, N. V. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353752 · Cited by 154
The effect of electrode displacements on pattern recognition based myoelectric control
Hargrove, L. J., Englehart, K. B., & Hudgins, B. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260681 · Cited by 153
Evaluation of EMG processing techniques using Information Theory
Farfán, F. D., Politti, J. C., & Felice, C. J. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-72 · Cited by 151
Myoelectric and Mechanical Manifestations of Muscle Fatigue in Voluntary Contractions
Merletti, R., & Roy, S. H. (1996) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1996.24.6.342 · Cited by 145
Making muscle-computer interfaces more practical
Saponas, T. S., Tan, D. S., Morris, D., Turner, J., & Landay, J. A. (2010) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753451 · Cited by 141
Innervation zones of the upper and lower limb muscles estimated by using multichannel surface EMG.
SAITOU, K., Masuda, T., Michikami, D., et al. (2000) · PubMed · Cited by 141
Robotic lower limb exoskeletons using proportional myoelectric control
Ferris, D. P., & Lewis, C. L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333984 · Cited by 136
Inhomogeneities in muscle activation reveal motor unit recruitment
Holtermann, A., Roeleveld, K., & Karlsson, J. S. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.09.003 · Cited by 135
Phinyomark, A., Hirunviriya, S., Limsakul, C., & Phukpattaranont, P. (2010) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · Cited by 134
He, J., Zhang, D., Sheng, X., Li, S., & Zhu, X. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2330356 · Cited by 134
Surface Electromyographic Signals Using Dry Electrodes
Laferriere, P., Lemaire, E. D., & Chan, A. D. C. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2164279 · Cited by 133
Performances of Hill-Type and Neural Network Muscle Models—Toward a Myosignal-Based Exoskeleton
Rosén, J., Fuchs, M. B., & Arcan, M. (1999) · Computers and Biomedical Research · doi:10.1006/cbmr.1999.1524 · Cited by 122
Karlsson, S., Yu, J., & Akay, M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764944 · Cited by 122
Hefftner, G., Zucchini, W., & Jaros, G. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1370 · Cited by 120
Automatic segmentation of surface EMG images: Improving the estimation of neuromuscular activity
Vieira, T., Merletti, R., & Mesin, L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.049 · Cited by 119
Sebelius, F., Rosén, B., & Lundborg, G. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2005.01.002 · Cited by 117
Fluctuating emg signals: Investigating long-term effects of pattern matching algorithms
Kaufmann, P. M., Englehart, K. B., & Platzner, M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627288 · Cited by 115
A real-time EMG pattern recognition method for virtual myoelectric hand control
Xing, K., Yang, P., Huang, J., Wang, Y., & Zhu, Q. (2014) · Neurocomputing · doi:10.1016/j.neucom.2013.12.010 · Cited by 113
Felzer, T., & Freisleben, B. (2002) · International ACM SIGACCESS Conference on Computers and Accessibility (ASSETS) · doi:10.1145/638249.638273 · Cited by 111
Hodgson, J. A., Finni, T. J., Lai, A. M., Edgerton, V. R., & Sinha, S. (2006) · Journal of Morphology · doi:10.1002/jmor.10421 · Cited by 110
Recognition of Electromyographic Signals Using Cascaded Kernel Learning Machine
Liu, Y., Huang, H., & Weng, C.-H. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897253 · Cited by 108
2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)
Aiello, M., Fabio Aloise, A., Baldoni, R., Febo Cincotti, A., Guger, C., Lazovik, A., Mecella, M., Pucci, P., Rinsma, J., Santucci, G., et al. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Cited by 108
Concentric-ring electrode systems for noninvasive detection of single motor unit activity
Farina, D., & Cescon, C. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959328 · Cited by 107
Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., & Malek, M. H. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.08.007 · Cited by 106
Classification of gait phases from lower limb EMG: Application to exoskeleton orthosis
Joshi, C., Lahiri, U., & Thakor, N. V. (2013) · 2013 IEEE Point-of-Care Healthcare Technologies (PHT) · doi:10.1109/pht.2013.6461326 · Cited by 105
A New Control Method for Power-Assisted Wheelchair Based on the Surface Myoelectric Signal
Oonishi, Y., Oh, S., & Hori, Y. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2051931 · Cited by 105
PROPORTIONAL MYOELECTRIC HAND CONTROL: AN EVALUATION
Sears, H. H., & Shaperman, J. (1991) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199102000-00005 · Cited by 103
Li, G., Li, Y., Yu, L., & Geng, Y. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0265-x · Cited by 101
GA-based Feature Subset Selection for Myoelectric Classification
Oskoei, M. A., & Hu, H. (2006) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2006.340145 · Cited by 100
Detection and Conditioning of Surface EMG Signals
Merletti, R., Botter, A., & Barone, U. (2016) · Wiley eBooks · doi:10.1002/9781119082934.ch03 · Cited by 98
Sub auditory speech recognition based on EMG signals
Jorgensen, C. C., Lee, D. D., & Agabon, S. (2004) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2003.1224072 · Cited by 98
Graupe, D., Salahi, J., & Zhang, D. (1985) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(85)90004-4 · Cited by 97
Toward subtle intimate interfaces for mobile devices using an EMG controller
Costanza, E., Inverso, S. A., & Allen, R. (2005) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1054972.1055039 · Cited by 96
Gestures as input: neuroelectric joysticks and keyboards
Wheeler, K., & Jorgensen, C. C. (2003) · IEEE Pervasive Computing · doi:10.1109/mprv.2003.1203754 · Cited by 95
IUI 2020: Proceedings of the 25th international conference on intelligent user interfaces
Paternò, F., Conati, N. O. C., Spano, L. D., & Tintarev, N. (2020) · Cited by 95
Continuous multifunction myoelectric control using pattern recognition
Englehart, K. B., Hudgins, B. S., & Chan, A. D. C. (2003) · Technology and Disability · doi:10.3233/tad-2003-15205 · Cited by 94
Human-machine interface for wheelchair control with EMG and its evaluation
Han, J.-S., Bien, Z., Kim, D., Lee, H.-E., & Kim, J. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279672 · Cited by 93
Intimate interfaces in action: assessing the usability and subtlety of emg-based motionless gestures
Costanza, E., Inverso, S. A., Allen, R., & Maes, P. (2007) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1240624.1240747 · Cited by 92
2003 IEEE/RSJ international conference on intelligent robots and systems (IROS 2003)
(2003) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2003.1248780 · Cited by 92
EMG Methods for Evaluating Muscle and Nerve Function
Schwartz, M. (2012) · InTech eBooks · doi:10.5772/1465 · Cited by 86
A Study on EMG-Based Control of Exoskeleton Robots for Human Lower-limb Motion Assist
He, H., & Kiguchi, K. (2007) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2007.4407405 · Cited by 84
Song, R., & Tong, R. K. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344728 · Cited by 83
EMG-Based Speech Recognition Using Hidden Markov Models With Global Control Variables
Lee, K.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915658 · Cited by 83
Jamison, J. C., & Caldwell, G. E. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.3.947 · Cited by 81
Continuous Detection and Decoding of Dexterous Finger Flexions With Implantable MyoElectric Sensors
Baker, J. J., Scheme, E., Englehart, K. B., Hutchinson, D. T., & Greger, B. E. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047590 · Cited by 80
Myo-electric signals to augment speech recognition
Chan, A. D. C., Englehart, K. B., Hudgins, B., & Lovely, D. F. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345373 · Cited by 77
Speech interfaces based upon surface electromyography
Jorgensen, C. C., & Dusan, S. (2009) · Speech Communication · doi:10.1016/j.specom.2009.11.003 · Cited by 76
Sugie, N., & Tsunoda, K. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325564 · Cited by 75
Intention detection using a neuro-fuzzy EMG classifier
Hussein, S. E., & Granat, M. H. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1175148 · Cited by 73
Chang, G.-C., Kang, W.-J., Luh, J.-J., Cheng, C., Lai, J., Chen, J. J., & Kuo, T. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(96)00006-9 · Cited by 72
Tucker, K. J., Falla, D., Graven‐Nielsen, T., & Farina, D. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.10.003 · Cited by 71
Phinyomark, A., Limsakul, C., & Phukpattaranont, P. (2011) · IETE Technical Review · doi:10.4103/0256-4602.83552 · Cited by 71
An efficient discriminant-based solution for small sample size problem
Das, K., & Nenadić, Z. (2008) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.036 · Cited by 70
Phinyomark, A., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Measurement Science Review · doi:10.2478/v10048-012-0015-8 · Cited by 68
Comparison of surface EMG monitoring electrodes for long-term use in rehabilitation device control
Pylatiuk, C., Muller-Riederer, M., Kargov, A., Schulz, S., Schill, O., Reischl, M., & Bretthauer, G. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209576 · Cited by 68
A myoelectric interface for robotic hand control using support vector machine
Yoshikawa, M., Mikawa, M., & Tanaka, K. (2007) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2007.4399301 · Cited by 67
EMG-Based Neuro-Fuzzy Control of a 4DOF Upper-Limb Power-Assist Exoskeleton
Kiguchi, K., Imada, Y., & Liyanage, M. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352969 · Cited by 67
Myocoder studies of multiple myopotential response.
Finley, F. R., & Wirta, R. W. (1967) · PubMed · Cited by 67
Outlier detection in high-density surface electromyographic signals
Marateb, H. R., Rojas-Martínez, M., Mansourian, M., Merletti, R., & Mañanas, M. Á. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0790-7 · Cited by 61
High-density EMG E-Textile systems for the control of active prostheses
Farina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627455 · Cited by 57
Human–machine interface based on muscular and brain signals applied to a robotic wheelchair
Ferreira, A., Silva, R. L., Celeste, W. C., Bastos-Filho, T., & Sarcinelli-Filho, M. (2007) · Journal of Physics Conference Series · doi:10.1088/1742-6596/90/1/012094 · Cited by 56
Ayachi, F., Boudaoud, S., & Marque, C. K. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1170-x · Cited by 52
Neuro-Fuzzy Surface EMG Pattern Recognition For Multifunctional Hand Prosthesis Control
Khezri, M., Jahed, M., & Sadati, N. (2007) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2007.4374610 · Cited by 50
Classification of prehensile EMG patterns with simplified fuzzy ARTMAP networks
Vuskovic, M. I., & Du, S. (2003) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2002.1007543 · Cited by 50
(2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2038249 · Cited by 50
Carozza, M. C., Cappiello, G., Stellin, G., Zaccone, F., Vecchi, F., Micera, S., & Dario, P. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1545585 · Cited by 48
Real-time Learning Method for Adaptable Motion-Discrimination using Surface EMG Signal
Kato, R., Yokoi, H., & Arai, T. (2006) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2006.282492 · Cited by 48
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Fluctuation and Noise Letters · doi:10.1142/s0219477512500289 · Cited by 45
EMG-based facial gesture recognition through versatile elliptic basis function neural network
Hamedi, M., Salleh, S., Astaraki, M., & Noor, A. M. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-73 · Cited by 45
Problems of bioelectric control
Kobrinskii, A. E., Bolkhovitin, S. V., Voskoboinikova, L. M., Ioffe, D. M., Polyan, E. P., Popov, B. P., Slavutskii, I. L., Sysin, A. J., & Yakobson, Y. S. (1960) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)70141-3 · Cited by 45
Rehbaum, H., Jiang, N., Paredes, L. P., et al. (2012) · doi:10.1109/embc.2012.6346187 · Cited by 44
Intelligent control and automation
(2016) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2016.7544232 · Cited by 43
A Five-fingered Underactuated Prosthetic Hand Control Scheme
Zhao, J., Xie, Z., Jiang, L., Cai, H., Liu, H., & Hirzinger, G. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639221 · Cited by 42
PCA and LDA for EMG-based control of bionic mechanical hand
Zhang, D., Xiong, A., Zhao, X., & Han, J. (2012) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2012.6246955 · Cited by 41
Simulation of Patient Specific Cervical Hip Fracture Surgery With a Volume Haptic Interface
Pettersson, J., Palmerius, K. L., Knutsson, H. E., Wahlström, O., Tillander, B. M., & Borga, M. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908099 · Cited by 40
A wavelet- and neural network-based voice system for a smart wheelchair control
Al‐Rousan, M., & Assaleh, K. T. (2009) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2009.02.005 · Cited by 39
Optimal Electrode Configurations for Finger Movement Classification using EMG
Andrews, A., Morin, E. L., & McLean, L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332520 · Cited by 39
WAVELET-BASED DENOISING ALGORITHM FOR ROBUST EMG PATTERN RECOGNITION
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2010) · Fluctuation and Noise Letters · doi:10.1142/s0219477511000466 · Cited by 38
Effect of upper-limb positions on motion pattern recognition using electromyography
Chen, L., Geng, Y., & Li, G. (2011) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp.2011.6100025 · Cited by 37
A computer game-based EMG biofeedback system for muscle rehabilitation
Lyons, G. M., Sharma, P., Baker, M., O'Malley, S., & Shanahan, A. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279682 · Cited by 36
Determining delay created by multifunctional prosthesis controllers
Farrell, T. R. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.03.0055 · Cited by 36
Myoelectric Signal Classification for Phoneme-Based Speech Recognition
Scheme, E., Hudgins, B. S., & Parker, P. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889175 · Cited by 35
On‐line supervising mechanism for learning data in surface electromyogram motion classifiers
Nishikawa, D., Yu, W., Yokoi, H., & Kakazu, Y. (2002) · Systems and Computers in Japan · doi:10.1002/scj.10245 · Cited by 34
Muceli, S., Jiang, N., & Farina, D. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627622 · Cited by 34
Non‐invasive assessment of motor unit anatomy in jaw‐elevator muscles
Castroflorio, T., Farina, D., Bottin, A., et al. (2005) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2005.01490.x · Cited by 34
Wavelet De-Noising of Electromyography
Qingju, Z., & Zhizeng, L. (2006) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2006.257406 · Cited by 34
2012 International Conference on Biomedical Engineering (ICoBE)
(2012) · doi:10.1109/icobe19561.2012 · Cited by 34
Recognition of grasp types through principal components of DWT based EMG features
Kakoty, N. M., & Hazarika, S. M. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975398 · Cited by 33
(2005) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2005.856816 · Cited by 33
Small Vocabulary Recognition Using Surface Electromyography in an Acoustically Harsh Environment
Betts, B. J., & Jorgensen, C. C. (2005) · Cited by 32
Use of myoelectric signals to recognize speech
Morse, M. S., Day, S. H., Trull, B., & Morse, H. (1989) · Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society, · doi:10.1109/iembs.1989.96459 · Cited by 32
Selection of sampling rate for EMG pattern recognition based prosthesis control
Li, G., Li, Y., Zhang, Z., Geng, Y., & Zhou, R. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626224 · Cited by 31
A human forearm and wrist motion assist exoskeleton robot with EMG-based Fuzzy-neuro control
Gopura, R. A. R. C., & Kiguchi, K. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762793 · Cited by 31
Cited by
Gesture recognition by instantaneous surface EMG images
Geng, W., Du, Y., Jin, W., Wei, W., Hu, Y., & Li, J. (2016) · Scientific Reports · doi:10.1038/srep36571 · Cited by 595
Health monitoring through wearable technologies for older adults: Smart wearables acceptance model
Li, J., Ma, Q., Chan, A. H., & Man, S. S. (2019) · Applied Ergonomics · doi:10.1016/j.apergo.2018.10.006 · Cited by 436
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
A novel attention-based hybrid CNN-RNN architecture for sEMG-based gesture recognition
Hu, Y., Wong, Y., Wei, W., Du, Y., Kankanhalli, M., & Geng, W. (2018) · PLOS ONE · doi:10.1371/journal.pone.0206049 · Cited by 398
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
Metadata
- Authors
- Hakonen, M., Piitulainen, H., & Visala, A.
- Venue
- Biomedical Signal Processing and Control
- Publisher
- Elsevier BV
- Published
- 2015-04
- Volume
- 18
- Pages
- 334-359
- ISSN
- 1746-8094 (ISSN-L)
- OpenAlex
- W2017085332
- Cited by
- 305
- References
- 229
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.