A review of implantable biosensors for closed-loop glucose control and other drug delivery applications
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Closed-loop drug delivery promises autonomous control of pharmacotherapy through the continuous monitoring of biomarker levels. For decades, researchers have strived for portable closed-loop systems capable of treating ambulatory patients with chronic conditions such as diabetes mellitus. After years of development, the first of these systems have left the laboratory and entered commercial use. This long-awaited advance reflects recent development of chronically stable implantable biosensors able to accurately measure biomarker levels in vivo. This review discusses the role of implantable biosensors in closed-loop drug delivery applications, with the intent to provide a resource for engineers and researchers studying such systems. We provide an overview of common biosensor designs and review the principle challenges in implementing long indwelling sensors: namely device sensitivity, selectivity, and lifetime. This review examines novel advances in transducer design, biological interface, and material biocompatibility, with a focus on recent academic and commercial work which provide successful strategies to overcome perennial challenges. This review focuses primarily on the topics of closed-loop glucose control and continuous glucose monitoring biosensors, which make up the overwhelming majority of published research in this area. We conclude with an overview of recent advances in closed-loop systems targeting applications outside blood glucose management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · cited 3×
“While use of mediators is common in the design of ex vivo sensors, second generation glucose sensors have seem limited deployment for in vivo applications due to concerns of mediator stability and possible toxicity (Wang, 2008).”
BackgroundMethodVeiseh, O., Doloff, J. C., Ma, M., Vegas, A. J., Tam, H. H., Bader, A. R., Li, J., Langan, E., Wyckoff, J., Loo, W. S., et al. (2015) · Nature Materials · doi:10.1038/nmat4290 · Cited by 897
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644 · cited 1×
“of clinical studies have explored ad hoc closed-loop systems comprising a mix of research and commercial devices (Bergenstal et al., 2016; Kovatchev et al., 2014; Kropff et al., 2015; Leelarathna et al., 2014; Renard et al., 2016; Tauschmann et al., 2016; Thabit et al., 2014; Thabit et al., 2015).”
BackgroundFernandez-Real, J.-M., Vayreda, M., Richart, C., Gutierrez, C., Broch, M., Vendrell, J., & Ricart, W. (2001) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.86.3.7305 · Cited by 567
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Home Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450 · cited 1×
“of clinical studies have explored ad hoc closed-loop systems comprising a mix of research and commercial devices (Bergenstal et al., 2016; Kovatchev et al., 2014; Kropff et al., 2015; Leelarathna et al., 2014; Renard et al., 2016; Tauschmann et al., 2016; Thabit et al., 2014; Thabit et al., 2015).”
BackgroundA Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Development of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302
Tissue response to implanted polymers: The significance of sample shape
Matlaga, B. F., Yasenchak, L. P., & Salthouse, T. N. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100308 · Cited by 295
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244
Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234
Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230 · cited 1×
“Phelps (2011) provides a more expansive examination of current drug delivery technology.”
BackgroundLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · cited 1×
“Though we caution against describing any material as universally biocompatible, certain materials including titanium (Hille, 1966; Laing, 1973; Steinemann, 1998), platinum (Agnew et al., 1986; Cowley and Woodward, 2011; Stensaas and Stensaas, 1978), certain glasses and ceramics (Clarke, 1992;…”
BackgroundA contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Clarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals
Gough, D. A., Kumosa, L. S., Routh, T. L., Lin, J. T., & Lucisano, J. Y. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001148 · Cited by 179
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
Some aspects of macrophage behavior at the implant interface
Salthouse, T. N. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180407 · Cited by 176 · cited 1×
“…a broad spectrum of materials show that hard, sharp, and rough surfaces contribute to more severe inflammatory response, greater accumulation of macrophages at the sensor interface, and faster formation of thicker fibrotic capsules (Matlaga et al., 1976; Salthouse, 1984; Veiseh et al., 2015).”
BackgroundQuinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172 · cited 1×
“…methacrylate)) and PEG (poly(ethylene glycol))-based hydrogels have garnered particular attention, following several in vivo studies reporting reduced levels of fibrosis, and/or prolonged function of coated biosensors (Abraham et al., 2005; Quinn et al., 1997; Quinn et al., 1995; Yu et al., 2008).”
BackgroundRebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size
Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815601869 · Cited by 107
Use of hydrogel coating to improve the performance of implanted glucose sensors
Yu, B., Wang, C., Ju, Y. M., West, L., Harmon, J., Moussy, Y., & Moussy, F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.11.010 · Cited by 105 · cited 1×
“There is also growing interest in the development of intraperitoneal CGM sensors, on the basis of improved glucose sensing kinetics (Burnett et al., 2014; Fougner et al., 2016), and the larger peritoneal space (Zisser et al., 2015).”
BackgroundRenard, E., Farret, A., Kropff, J., Bruttomesso, D., Messori, M., Place, J., Visentin, R., Calore, R., Toffanin, C., Di Palma, F., et al. (2016) · Diabetes Care · doi:10.2337/dc16-0008 · Cited by 104
Time‐dependent inactivation of immobilized glucose oxidase and catalase
Tse, P. H. S., & Gough, D. A. (1987) · Biotechnology and Bioengineering · doi:10.1002/bit.260290607 · Cited by 95
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.017 · Cited by 87
Feasibility of Continuous Long-Term Glucose Monitoring from a Subcutaneous Glucose Sensor in Humans
Gilligan, B. C., Shults, M., Rhodes, R. K., Jacobs, P. G., Brauker, J. H., Pintar, T. J., & Updike, S. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198089 · Cited by 71
WU, Y., ROJAS, A., GRIFFITH, G., SKRZYPCHAK, A., LAFAYETTE, N., BARTLETT, R., & MEYERHOFF, M. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.025 · Cited by 65
Glucose in the saliva of the non-diabetic and the diabetic patient
Campbell, M. J. A. (1965) · Archives of Oral Biology · doi:10.1016/0003-9969(65)90020-8 · Cited by 58
Hara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066020 · Cited by 57
Self-citationBurnett, D. R., Huyett, L. M., Zisser, H. C., Doyle, F. J., & Mensh, B. D. (2014) · Diabetes · doi:10.2337/db13-1649 · Cited by 52
Regulation Catches Up to Reality: Nonadjunctive Use of Continuous Glucose Monitoring Data
Edelman, S. V. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816667749 · Cited by 51 · cited 1×
“…first several generations of commercial CGM devices were labeled only for adjunctive use, as a complement to SMBG devices (Castle and Jacobs, 2016; Edelman, 2017), and were used to discern changing trends in glucose levels, or to warn of impending hypoglycemia, but not to make definite…”
MethodKlueh, U., Kaur, M., Montrose, D. C., & Kreutzer, D. L. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100407 · Cited by 33
Histological Reaction to Polyimide Films in the Cochlea
Haggerty, H. S., & Lusted, H. S. (1989) · Acta Oto-Laryngologica · doi:10.3109/00016488909127474 · Cited by 31
Cited by
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
Stimuli-responsive transdermal microneedle patches
Makvandi, P., Jamaledin, R., Chen, G., Baghbantaraghdari, Z., Zare, E. N., Di Natale, C., Onesto, V., Vecchione, R., Lee, J., Tay, F. R., et al. (2021) · Materials Today · doi:10.1016/j.mattod.2021.03.012 · Cited by 283
Metadata
- Authors
- Scholten, K., & Meng, E.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 544
- Issue
- 2
- Pages
- 319-334
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2791879669
- Cited by
- 102
- References
- 44
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.