STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 201–300 of 47,868
Body fluid volume determination via body composition spectroscopy in health and disease
Moissl, U. M., Wabel, P., Chamney, P. W., Bosaeus, I., Levin, N. W., Bosy-Westphal, A., Korth, O., Müller, M. J., Ellegård, L., Malmros, V., et al. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/9/012 · Cited by 608
Moor, B. K., Bouaicha, S., Rothenfluh, D. A., Sukthankar, A., & Gerber, C. (2013) · The Bone & Joint Journal · doi:10.1302/0301-620x.95b7.31028 · Cited by 598
Fuchs‐Buder, T., Claudius, C., Skovgaard, L. T., Eriksson, L. I., Mirakhur, R. K., & Viby‐Mogensen, J. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01352.x · Cited by 606
Petersen, S. E., Aung, N., Sanghvi, M. M., Zemrak, F., Fung, K., Paiva, J. M., Francis, J. M., Khanji, M. Y., Lukaschuk, E., Lee, A. M., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0327-9 · Cited by 607
“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
An International Ki67 Reproducibility Study
Polley, M.-Y. C., Leung, S. C. Y., McShane, L. M., Gao, D., Hugh, J. C., Mastropasqua, M. G., Viale, G., Zabaglo, L. A., Penault-Llorca, F., Bartlett, J. M. S., et al. (2013) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djt306 · Cited by 595
Time Course of Sleep-related Breathing Disorders in First-Ever Stroke or Transient Ischemic Attack
PARRA, O., ARBOIX, A., BECHICH, S., GARCÍA-EROLES, L., MONTSERRAT, J. M., LÓPEZ, J. A., BALLESTER, E., GUERRA, J. M., & SOPEÑA, J. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9903139 · Cited by 598
Avendi, M. R., Kheradvar, A., & Jafarkhani, H. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.01.005 · Cited by 593
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Wang, C., Catlin, D. H., Demers, L. M., Starcevic, B., & Swerdloff, R. S. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031287 · Cited by 580
Deurenberg-Yap, M., Schmidt, G., van Staveren, W., & Deurenberg, P. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801353 · Cited by 580
Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.212 · Cited by 583
Liang, W., Menke, A. L., Driessen, A., Koek, G. H., Lindeman, J. H., Stoop, R., Havekes, L. M., Kleemann, R., & van den Hoek, A. M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115922 · Cited by 577
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Single prediction equation for bioelectrical impedance analysis in adults aged 20–94 years
Kyle, U. G., Genton, L., Karsegard, L., Slosman, D. O., & Pichard, C. (2001) · Nutrition · doi:10.1016/s0899-9007(00)00553-0 · Cited by 575
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
A Systematic Review of Faces Scales for the Self-report of Pain Intensity in Children
Tomlinson, D., von Baeyer, C. L., Stinson, J. N., & Sung, L. (2010) · Pediatrics · doi:10.1542/peds.2010-1609 · Cited by 571
Physical Inactivity: Prevalence and Associated Variables in Brazilian Adults
HALLAL, P. C., VICTORA, C. G., WELLS, J. C. K., & LIMA, R. C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000093615.33774.0e · Cited by 602
Accuracy and precision of objective refraction from wavefront aberrations
Thibos, L. N., Hong, X., Bradley, A., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.9 · Cited by 570
Evaluation of the Modification of Diet in Renal Disease Study Equation in a Large Diverse Population
Stevens, L. A., Coresh, J., Feldman, H. I., Greene, T., Lash, J. P., Nelson, R. G., Rahman, M., Deysher, A. E., Zhang, Y. (., Schmid, C. H., et al. (2007) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007020199 · Cited by 574
Severity of Airflow Limitation Is Associated with Severity of Airway Inflammation in Smokers
DI STEFANO, A., CAPELLI, A., LUSUARDI, M., BALBO, P., VECCHIO, C., MAESTRELLI, P., MAPP, C. E., FABBRI, L. M., DONNER, C. F., & SAETTA, M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.4.9802078 · Cited by 572
External Validation of a Measurement Tool to Assess Systematic Reviews (AMSTAR)
Shea, B. J., Bouter, L. M., Peterson, J., Boers, M., Andersson, N., Ortiz, Z., Ramsay, T., Bai, A., Shukla, V. K., & Grimshaw, J. M. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001350 · Cited by 569
Changes in Mitochondrial DNA as a Marker of Nucleoside Toxicity in HIV-Infected Patients
Côté, H. C. F., Brumme, Z. L., Craib, K. J. P., Alexander, C. S., Wynhoven, B., Ting, L., Wong, H., Harris, M., Harrigan, P. R., O'Shaughnessy, M. V., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012035 · Cited by 573
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
RELIABILITY AND VALIDITY OF THE INTERNATIONAL PHYSICAL ACTIVITY QUESTIONNAIRE (IPAQ)
Hallal, P. C., & Victora, C. G. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000117161.66394.07 · Cited by 561
White matter characterization with diffusional kurtosis imaging
Fieremans, E., Jensen, J. H., & Helpern, J. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.006 · Cited by 561
Schwartz, G. J., Schneider, M. F., Maier, P. S., Moxey-Mims, M., Dharnidharka, V. R., Warady, B. A., Furth, S. L., & Muñoz, A. (2012) · Kidney International · doi:10.1038/ki.2012.169 · Cited by 566
Difference in disease features between childhood‐onset and adult‐onset systemic lupus erythematosus
Brunner, H. I., Gladman, D. D., Ibañez, D., Urowitz, M. D., & Silverman, E. D. (2008) · Arthritis & Rheumatism · doi:10.1002/art.23204 · Cited by 554
Refractive error in children in an urban population in New Delhi.
Murthy, G. V. S., Gupta, S., Ellwein, L. B., Muñoz, S., Pokharel, G. P., Sanga, L., & Bachani, D. (2002) · PubMed · Cited by 556
Webster, K. E., Wittwer, J. E., & Feller, J. A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.10.005 · Cited by 556
Hoek, F. J. (2003) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfg349 · Cited by 564
Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis
Pfister, A., West, A. M., Bronner, S., & Noah, J. A. (2014) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2014.909540 · Cited by 552
The Trunk Impairment Scale: a new tool to measure motor impairment of the trunk after stroke
Verheyden, G., Nieuwboer, A., Mertin, J., Preger, R., Kiekens, C., & De Weerdt, W. (2004) · Clinical Rehabilitation · doi:10.1191/0269215504cr733oa · Cited by 550
The tibial tuberosity–trochlear groove distance; a comparative study between CT and MRI scanning
Schoettle, P. B., Zanetti, M., Seifert, B., Pfirrmann, C. W. A., Fucentese, S. F., & Romero, J. (2006) · The Knee · doi:10.1016/j.knee.2005.06.003 · Cited by 554
Estimating sleep parameters using an accelerometer without sleep diary
van Hees, V. T., Sabia, S., Jones, S. E., Wood, A. R., Anderson, K. N., Kivimäki, M., Frayling, T. M., Pack, A. I., Bucan, M., Trenell, M. I., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-31266-z · Cited by 554
Tabb, D. L., Vega-Montoto, L., Rudnick, P. A., Variyath, A. M., Ham, A.-J. L., Bunk, D. M., Kilpatrick, L. E., Billheimer, D. D., Blackman, R. K., Cardasis, H. L., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr9006365 · Cited by 551
Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Burd, E. M. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00074-09 · Cited by 550
Kroke, A., Klipstein-Grobusch, K., Voss, S., Möseneder, J., Thielecke, F., Noack, R., & Boeing, H. (1999) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/70.4.439 · Cited by 550
Jovicich, J., Czanner, S., Han, X., Salat, D., van der Kouwe, A., Quinn, B., Pacheco, J., Albert, M., Killiany, R., & Blacker, D. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.010 · Cited by 559
Erhardt, J. G., Estes, J. E., Pfeiffer, C. M., Biesalski, H. K., & Craft, N. E. (2004) · The Journal of Nutrition · doi:10.1093/jn/134.11.3127 · Cited by 553
Wang, Z., Ying, Z., Bosy-Westphal, A., Zhang, J., Schautz, B., Later, W., Heymsfield, S. B., & Müller, M. J. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2010.29885 · Cited by 546
MedCalc: a new computer program for medical statistics
Schoonjans, F., Zalata, A., Depuydt, C. E., & Comhaire, F. H. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01703-8 · Cited by 547
Conway, J. M., Ingwersen, L. A., & Moshfegh, A. J. (2004) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2004.01.007 · Cited by 546
Boussel, L., Rayz, V., McCulloch, C., Martin, A., Acevedo-Bolton, G., Lawton, M., Higashida, R., Smith, W. S., Young, W. L., & Saloner, D. (2008) · Stroke · doi:10.1161/strokeaha.108.521617 · Cited by 535
A methodology for evaluation of boundary detection algorithms on medical images
Chalana, V., & Kim, Y. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640755 · Cited by 542
Fossati, R., Confalonieri, C., Torri, V, Ghislandi, E., Penna, A., Pistotti, V, Tinazzi, A., & Liberati, A. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.10.3439 · Cited by 546
Contrast-enhanced magnetic resonance imaging of myocardium at risk
Fieno, D. S., Kim, R. J., Chen, E.-L., Lomasney, J. W., Klocke, F. J., & Judd, R. M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00958-x · Cited by 547
Lanthanides in Luminescent Thermometry
Brites, C. D. S., Millán, A., & Carlos, L. D. (2016) · Handbook on the Physics and Chemistry of Rare Earths · doi:10.1016/bs.hpcre.2016.03.005 · Cited by 536
Measurement of heart rate and Q-T interval in the conscious mouse
Mitchell, G. F., Jeron, A., & Koren, G. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.3.h747 · Cited by 544
Statistical guidelines for the analysis of data obtained from one or both eyes
Armstrong, R. A. (2013) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12009 · Cited by 522
Comparison of the LASA Physical Activity Questionnaire with a 7-day diary and pedometer
Stel, V. S., Smit, J. H., Pluijm, S. M. F., Visser, M., Deeg, D. J. H., & Lips, P. (2004) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2003.07.008 · Cited by 539
Clinimetric evaluation of shoulder disability questionnaires: a systematic review of the literature
Bot, S. D. M., Terwee, C. B., van der Windt, D. A. W. M., Bouter, L. M., Dekker, J., & de Vet, H. C. W. (2004) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2003.007724 · Cited by 541
Park, S. H., Kim, P. N., Kim, K. W., Lee, S. W., Yoon, S. E., Park, S. W., Ha, H. K., Lee, M.-G., Hwang, S., Lee, S.-G., et al. (2006) · Radiology · doi:10.1148/radiol.2391050361 · Cited by 542
Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease
Galna, B., Barry, G., Jackson, D., Mhiripiri, D., Olivier, P., & Rochester, L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.01.008 · Cited by 544
Refractive error in children in a rural population in India.
Dandona, R., Dandona, L., Marmamula, S., Sahare, P., Narsaiah, S., Muñoz, S., Pokharel, G. P., & Ellwein, L. B. (2002) · PubMed · Cited by 534
Observations on the use of statistical methods in Food Science and Technology
Granato, D., de Araújo Calado, V. M., & Jarvis, B. (2014) · Food Research International · doi:10.1016/j.foodres.2013.10.024 · Cited by 525
Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP)
Bellner, J., Romner, B., Reinstrup, P., Kristiansson, K.-A., Ryding, E., & Brandt, L. (2004) · Surgical Neurology · doi:10.1016/j.surneu.2003.12.007 · Cited by 527
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Best method in clinical practice and in research studies to determine left atrial size
Lester, S. J., Ryan, E. W., Schiller, N. B., & Foster, E. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00446-4 · Cited by 535
Goedhart, P. T., Khalilzada, M., Bezemer, R., Merza, J., & Ince, C. (2007) · Optics Express · doi:10.1364/oe.15.015101 · Cited by 531
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
The Functional Independence Measure: A comparative validity and reliability study
Kidd, D., Stewart, G., Baldry, J., Johnson, J., Rossiter, D., Petruckevitch, A., & Thompson, A. J. (1995) · Disability and Rehabilitation · doi:10.3109/09638289509166622 · Cited by 529
Edvardsen, T., Gerber, B. L., Garot, J., Bluemke, D. A., Lima, J. A. C., & Smiseth, O. A. (2002) · Circulation · doi:10.1161/01.cir.0000019907.77526.75 · Cited by 523
Food-frequency questionnaires: a review of their design, validation and utilisation
Cade, J. E., Burley, V. J., Warm, D. L., Thompson, R. L., & Margetts, B. M. (2004) · Nutrition Research Reviews · doi:10.1079/nrr200370 · Cited by 518
Samozino, P., Rabita, G., Dorel, S., Slawinski, J., Peyrot, N., Saez de Villarreal, E., & Morin, J. ‐. (2016) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12490 · Cited by 497
Preclinical prediction of AD using neuropsychological tests
ALBERT, M. S., MOSS, M. B., TANZI, R., & JONES, K. (2001) · Journal of the International Neuropsychological Society · doi:10.1017/s1355617701755105 · Cited by 519
A Note On "A Concordance Correlation Coefficient to Evaluate Reproducibility"
Nickerson, C. A. E. (1997) · Biometrics · doi:10.2307/2533516 · Cited by 510
Recruitment and Derecruitment During Acute Respiratory Failure: An Experimental Study
PELOSI, P., GOLDNER, M., McKIBBEN, A., ADAMS, A., ECCHER, G., CAIRONI, P., LOSAPPIO, S., GATTINONI, L., & MARINI, J. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2007010 · Cited by 524
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
How valid and reliable are patient satisfaction data? An analysis of 195 studies
Sitzia, J. (1999) · International Journal for Quality in Health Care · doi:10.1093/intqhc/11.4.319 · Cited by 515
Early Detection of Airway Wall Remodeling and Eosinophilic Inflammation in Preschool Wheezers
Saglani, S., Payne, D. N., Zhu, J., Wang, Z., Nicholson, A. G., Bush, A., & Jeffery, P. K. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200702-212oc · Cited by 513
Nielsen, J. C., Kristensen, L., Andersen, H. R., Mortensen, P. T., Pedersen, O. L., & Pedersen, A. K. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00757-5 · Cited by 506
Assessment of cerebral pressure autoregulation in humans - a review of measurement methods
Panerai, R. B. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/3/001 · Cited by 508
Amado, L. C., Gerber, B. L., Gupta, S. N., Rettmann, D. W., Szarf, G., Schock, R., Nasir, K., Kraitchman, D. L., & Lima, J. A. C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.020 · Cited by 508
Verburg, B. O., Steegers, E. A. P., De Ridder, M., Snijders, R. J. M., Smith, E., Hofman, A., Moll, H. A., Jaddoe, V. W. V., & Witteman, J. C. M. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5225 · Cited by 506
Van Noorden, R., Maher, B., & Nuzzo, R. (2014) · Nature · doi:10.1038/514550a · Cited by 508
Ekelund, U., Sepp, H., Brage, S., Becker, W., Jakes, R., Hennings, M., & Wareham, N. J. (2006) · Public Health Nutrition · doi:10.1079/phn2005840 · Cited by 499
Validity of the Polar S810 Heart Rate Monitor to Measure R-R Intervals at Rest
GAMELIN, F. X., BERTHOIN, S., & BOSQUET, L. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000218135.79476.9c · Cited by 509
Single platform flow cytometric absolute CD34+ cell counts based on the ISHAGE guidelines
Keeney, M., Chin-Yee, I., Weir, K., Popma, J., Nayar, R., & Sutherland, D. R. (1998) · Cytometry · doi:10.1002/(sici)1097-0320(19980415)34:2<61::aid-cyto1>3.0.co;2-f · Cited by 501
van der Lee, J. H., de Groot, V., Beckerman, H., Wagenaar, R. C., Lankhorst, G. J., & Bouter, L. M. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.18668 · Cited by 500
The Repeatability of Clinical Measurements of Dry Eye
Nichols, K. K., Mitchell, G. L., & Zadnik, K. (2004) · Cornea · doi:10.1097/00003226-200404000-00010 · Cited by 493
Crenn, P., Coudray–Lucas, C., Thuillier, F., Cynober, L., & Messing, B. (2000) · Gastroenterology · doi:10.1053/gast.2000.20227 · Cited by 498
Asher, M. I., Rutter, C. E., Bissell, K., Chiang, C.-Y., El Sony, A., Ellwood, E., Ellwood, P., García-Marcos, L., Marks, G. B., Morales, E., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01450-1 · Cited by 466
Miyatake, K., Yamagishi, M., Tanaka, N., Uematsu, M., Yamazaki, N., Mine, Y., Sano, A., & Hirama, M. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00421-l · Cited by 495
Cerdá, M., Wall, M., Keyes, K. M., Galea, S., & Hasin, D. (2012) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2011.06.011 · Cited by 490
Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography
Leung, C. K.-S., Cheung, C. Y.-L., Weinreb, R. N., Qiu, Q., Liu, S., Li, H., Xu, G., Fan, N., Huang, L., Pang, C.-P., et al. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.013 · Cited by 486
Assessment of Physical Activity among Children and Adolescents: A Review and Synthesis
Kohl, H. W., Fulton, J. E., & Caspersen, C. J. (2000) · Preventive Medicine · doi:10.1006/pmed.1999.0542 · Cited by 485
van Hedel, H. J., Wirz, M., & Dietz, V. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.02.010 · Cited by 485
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Corticosteroids contribute to muscle weakness in chronic airflow obstruction.
Decramer, M., Lacquet, L. M., Fagard, R., & Rogiers, P. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.1.8025735 · Cited by 489
Shu, X. O., Yang, G., Jin, F., Liu, D., Kushi, L., Wen, W., Gao, Y.-T., & Zheng, W. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601738 · Cited by 484
Psychometric adequacy of the Tinnitus Handicap Inventory (THI) for evaluating treatment outcome.
Newman, C. W., Sandridge, S. A., & Jacobson, G. P. (1998) · PubMed · Cited by 553
Brun, P., Tribouilloy, C., Duval, A.-M., Iserin, L., Meguira, A., Pelle, G., & Dubois-Rande, J.-L. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90112-z · Cited by 478
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Glaucoma in Mongolia: A Population-Based Survey in Hövsgöl Province, Northern Mongolia
Foster, P. J. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100140435011 · Cited by 474
Harrison, A., Sullivan, S., Tchanturia, K., & Treasure, J. (2010) · Psychological Medicine · doi:10.1017/s0033291710000036 · Cited by 480
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 470
Noninvasive Pulse Wave Analysis for the Early Detection of Vascular Disease
Cohn, J. N., Finkelstein, S., McVeigh, G., Morgan, D., LeMay, L., Robinson, J., & Mock, J. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.503 · Cited by 474
Organ-tissue mass measurement allows modeling of REE and metabolically active tissue mass
Gallagher, D., Belmonte, D., Deurenberg, P., Wang, Z., Krasnow, N., Pi-Sunyer, F. X., & Heymsfield, S. B. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.275.2.e249 · Cited by 470
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.