STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 301–400 of 47,868
Scheltens, P., Launer, L. J., Barkhof, F., Weinstein, H. C., & Gool, W. A. (1995) · Journal of Neurology · doi:10.1007/bf00868807 · Cited by 472
Cliff, D. P., Reilly, J. J., & Okely, A. D. (2009) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2008.10.008 · Cited by 464
Body surface area in normal-weight, overweight, and obese adults. A comparison study
Verbraecken, J., Van de Heyning, P., De Backer, W., & Van Gaal, L. (2006) · Metabolism · doi:10.1016/j.metabol.2005.11.004 · Cited by 464
Owen, C. G., Rudnicka, A. R., Mullen, R., Barman, S. A., Monekosso, D., Whincup, P. H., Ng, J., & Paterson, C. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3018 · Cited by 465
Sergi, G., De Rui, M., Veronese, N., Bolzetta, F., Berton, L., Carraro, S., Bano, G., Coin, A., Manzato, E., & Perissinotto, E. (2015) · Clinical Nutrition · doi:10.1016/j.clnu.2014.07.010 · Cited by 467
JOHNSON, R. K., DRISCOLL, P., & GORAN, M. I. (1996) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(96)00293-3 · Cited by 467
Psychometric scores and persistence of irritable bowel after infectious diarrhoea
Gwee, K. A., Read, N. W., Graham, J. C., McKendrick, M. W., Collins, S. M., Marshall, J. S., & Walters, S. J. (1996) · The Lancet · doi:10.1016/s0140-6736(96)90341-4 · Cited by 467
Gmel, G., & Rehm, J. (2004) · Contemporary Drug Problems · doi:10.1177/009145090403100304 · Cited by 466
Whelton, P. K., Appel, L. J., Sacco, R. L., Anderson, C. A. M., Antman, E. M., Campbell, N., Dunbar, S. B., Frohlich, E. D., Hall, J. E., Jessup, M., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318279acbf · Cited by 463
Ohkawara, K., Oshima, Y., Hikihara, Y., Ishikawa-Takata, K., Tabata, I., & Tanaka, S. (2011) · British Journal of Nutrition · doi:10.1017/s0007114510005441 · Cited by 458
Kirkley, A., Alvarez, C., & Griffin, S. (2003) · Clinical Journal of Sport Medicine · doi:10.1097/00042752-200303000-00004 · Cited by 460
Li, T.-S., Cheng, K., Malliaras, K., Smith, R. R., Zhang, Y., Sun, B., Matsushita, N., Blusztajn, A., Terrovitis, J., Kusuoka, H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.029 · Cited by 461
Stanescu, D., Sanna, A., Veriter, C., Kostianev, S., Calcagni, P. G., Fabbri, L. M., & Maestrelli, P. (1996) · Thorax · doi:10.1136/thx.51.3.267 · Cited by 462
Byrne, C., & Lim, C. L. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.026344 · Cited by 456
Gungor, N., Saad, R., Janosky, J., & Arslanian, S. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2003.09.045 · Cited by 457
Vessel co-option mediates resistance to anti-angiogenic therapy in liver metastases
Frentzas, S., Simoneau, E., Bridgeman, V. L., Vermeulen, P. B., Foo, S., Kostaras, E., Nathan, M. R., Wotherspoon, A., Gao, Z.-H., Shi, Y., et al. (2016) · Nature Medicine · doi:10.1038/nm.4197 · Cited by 454
Statistical Analysis Quick Reference Guidebook: With SPSS Examples
Elliott, A. C., & Woodward, W. A. (2006) · SAGE Publications Pvt. Ltd eBooks · Cited by 681
Reliability and validity of a visual analog scale for acute abdominal pain in the ED
Gallagher, E. J., Bijur, P. E., Latimer, C., & Silver, W. (2002) · The American Journal of Emergency Medicine · doi:10.1053/ajem.2002.33778 · Cited by 457
Ferreira, V. M., Piechnik, S. K., Dall'Armellina, E., Karamitsos, T. D., Francis, J. M., Choudhury, R. P., Friedrich, M. G., Robson, M. D., & Neubauer, S. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-42 · Cited by 460
Sugeng, L., Mor-Avi, V., Weinert, L., Niel, J., Ebner, C., Steringer-Mascherbauer, R., Schmidt, F., Galuschky, C., Schummers, G., Lang, R. M., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.626143 · Cited by 459
Peyton, P. J., & Chong, S. W. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ee3130 · Cited by 456
Endocrine Control of Body Composition in Infancy, Childhood, and Puberty
Veldhuis, J. D., Roemmich, J. N., Richmond, E. J., Rogol, A. D., Lovejoy, J. C., Sheffield-Moore, M., Mauras, N., & Bowers, C. Y. (2005) · Endocrine Reviews · doi:10.1210/er.2003-0038 · Cited by 452
Accurate automatic estimation of total intracranial volume: A nuisance variable with less nuisance
Malone, I. B., Leung, K. K., Clegg, S., Barnes, J., Whitwell, J. L., Ashburner, J., Fox, N. C., & Ridgway, G. R. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.034 · Cited by 459
Meyer, O., Labarre, C., Dougados, M., Goupille, P., Cantagrel, A., Dubois, A., Nicaise-Roland, P., Sibilia, J., & Combe, B. (2003) · Annals of the Rheumatic Diseases · doi:10.1136/ard.62.2.120 · Cited by 456
Martin, A. M., Bindra, R., Curcio, P., Cicero, S., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00594.x · Cited by 451
Chien, M., Huang, T., & Wu, Y. (2008) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2008.01854.x · Cited by 451
van der Lee, J. H., Beckerman, H., Knol, D. L., de Vet, H. C. W., & Bouter, L. M. (2004) · Stroke · doi:10.1161/01.str.0000126900.24964.7e · Cited by 456
Performance of seven consumer sleep-tracking devices compared with polysomnography
Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021) · Sleep · doi:10.1093/sleep/zsaa291 · Cited by 433
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Sebastien-Bolz, S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3687-3 · Cited by 448
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
Accelerometry and physical activity questionnaires - a systematic review
Skender, S., Ose, J., Chang-Claude, J., Paskow, M., Brühmann, B., Siegel, E. M., Steindorf, K., & Ulrich, C. M. (2016) · BMC Public Health · doi:10.1186/s12889-016-3172-0 · Cited by 449
ESCODD (European Standards Committee on Oxidative DNA Damage), Gedik, C. M., & Collins, A. (2005) · The FASEB Journal · doi:10.1096/fj.04-1767fje · Cited by 449
Rectal Carcinoma: Thin-Section MR Imaging for Staging in 28 Patients
Brown, G., Richards, C. J., Newcombe, R. G., Dallimore, N. S., Radcliffe, A. G., Carey, D. P., Bourne, M. W., & Williams, G. T. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap35215 · Cited by 451
Hassan, B. S., Mockett, S., & Doherty, M. (2001) · Annals of the Rheumatic Diseases · doi:10.1136/ard.60.6.612 · Cited by 451
Deprivation, Diet, and Food-Retail Access: Findings from the Leeds ‘Food Deserts' Study
Wrigley, N., Warm, D., & Margetts, B. (2003) · Environment and Planning A: Economy and Space · doi:10.1068/a35150 · Cited by 447
Sullivan, K. J., Tilson, J. K., Cen, S. Y., Rose, D. K., Hershberg, J., Correa, A., Gallichio, J., McLeod, M., Moore, C., Wu, S. S., et al. (2011) · Stroke · doi:10.1161/strokeaha.110.592766 · Cited by 445
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
McLester, C. N., Nickerson, B. S., Kliszczewicz, B. M., & McLester, J. R. (2020) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2018.10.008 · Cited by 426
Vogel, M., Schmidt, M. R., Kristiansen, S. B., Cheung, M., White, P. A., Sorensen, K., & Redington, A. N. (2002) · Circulation · doi:10.1161/01.cir.0000013773.67850.ba · Cited by 443
Mapping the human connectome at multiple scales with diffusion spectrum MRI
Cammoun, L., Gigandet, X., Meskaldji, D., Thiran, J. P., Sporns, O., Do, K. Q., Maeder, P., Meuli, R., & Hagmann, P. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.09.031 · Cited by 469
Sassi, R. H., Dardouri, W., Yahmed, M. H., Gmada, N., Mahfoudhi, M. E., & Gharbi, Z. (2009) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b425d2 · Cited by 431
Rudd, J. H. F., Myers, K. S., Bansilal, S., Machac, J., Pinto, C. A., Tong, C., Rafique, A., Hargeaves, R., Farkouh, M., Fuster, V., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.050294 · Cited by 444
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Measures of Obesity Are Associated With Vascular Stiffness in Young and Older Adults
Wildman, R. P., Mackey, R. H., Bostom, A., Thompson, T., & Sutton-Tyrrell, K. (2003) · Hypertension · doi:10.1161/01.hyp.0000090360.78539.cd · Cited by 441
Rizzardi, A. E., Johnson, A. T., Vogel, R. I., Pambuccian, S. E., Henriksen, J., Skubitz, A. P., Metzger, G. J., & Schmechel, S. C. (2012) · Diagnostic Pathology · doi:10.1186/1746-1596-7-42 · Cited by 435
McCormack, S. E., Shaham, O., McCarthy, M. A., Deik, A. A., Wang, T. J., Gerszten, R. E., Clish, C. B., Mootha, V. K., Grinspoon, S. K., & Fleischman, A. (2013) · Pediatric Obesity · doi:10.1111/j.2047-6310.2012.00087.x · Cited by 440
RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise
Gilgen-Ammann, R., Schweizer, T., & Wyss, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04142-5 · Cited by 438
Bassetti, C. L., Milanova, M., & Gugger, M. (2006) · Stroke · doi:10.1161/01.str.0000208215.49243.c3 · Cited by 439
Hsu, S. S.-P., Gateno, J., Bell, R. B., Hirsch, D. L., Markiewicz, M. R., Teichgraeber, J. F., Zhou, X., & Xia, J. J. (2013) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2012.03.027 · Cited by 435
Normative data for the 12 item WHO Disability Assessment Schedule 2.0
Andrews, G., Kemp, A., Sunderland, M., Von Korff, M., & Ustun, T. B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008343 · Cited by 437
Microfluidics Digital PCR Reveals a Higher than Expected Fraction of Fetal DNA in Maternal Plasma
Lun, F. M. F., Chiu, R. W. K., Allen Chan, K. C., Yeung Leung, T., Kin Lau, T., & Dennis Lo, Y. M. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.111385 · Cited by 433
Pierce, C. B., Muñoz, A., Ng, D. K., Warady, B. A., Furth, S. L., & Schwartz, G. J. (2021) · Kidney International · doi:10.1016/j.kint.2020.10.047 · Cited by 420
Kuecherer, H. F., Muhiudeen, I. A., Kusumoto, F. M., Lee, E., Moulinier, L. E., Cahalan, M. K., & Schiller, N. B. (1990) · Circulation · doi:10.1161/01.cir.82.4.1127 · Cited by 440
Jacobsen, D. W., Gatautis, V. J., Green, R., Robinson, K., Savon, S. R., Secic, M., Ji, J., Otto, J. M., & Taylor, L. M. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.6.873 · Cited by 435
Aboudara, C., Nielsen, I., Huang, J. C., Maki, K., Miller, A. J., & Hatcher, D. (2009) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2007.04.043 · Cited by 425
Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
Reinhart, K., Kuhn, H.-J., Hartog, C., & Bredle, D. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2337-y · Cited by 437
Gerber, B. L., Belge, B., Legros, G. J., Lim, P., Poncelet, A., Pasquet, A., Gisellu, G., Coche, E., & Vanoverschelde, J.-L. J. (2006) · Circulation · doi:10.1161/circulationaha.104.529511 · Cited by 430
A Note on the Concordance Correlation Coefficient
Steichen, T. J., & Cox, N. J. (2002) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0200200206 · Cited by 427
Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428
Should the Schwartz formula for estimation of GFR be replaced by cystatin C formula?
Filler, G., & Lepage, N. (2003) · Pediatric Nephrology · doi:10.1007/s00467-003-1271-5 · Cited by 431
Bonetti, P. O., Barsness, G. W., Keelan, P. C., Schnell, T. I., Pumper, G. M., Kuvin, J. T., Schnall, R. P., Holmes, D. R., Higano, S. T., & Lerman, A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00329-2 · Cited by 427
Kinnersley, P. (2000) · BMJ · doi:10.1136/bmj.320.7241.1043 · Cited by 428
Schindler, T. H., Schelbert, H. R., Quercioli, A., & Dilsizian, V. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.04.007 · Cited by 424
Reproducibility and Validity of Food Frequency Questionnaires
Willett, W., & Lenart, E. (2012) · Nutritional Epidemiology · doi:10.1093/acprof:oso/9780199754038.003.0006 · Cited by 427
Boston, R. C., Stefanovski, D., Moate, P. J., Sumner, A. E., Watanabe, R. M., & Bergman, R. N. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322641060 · Cited by 431
Dorosz, J. L., Lezotte, D. C., Weitzenkamp, D. A., Allen, L. A., & Salcedo, E. E. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.037 · Cited by 427
Hozumi, T., Yoshida, K., Akasaka, T., Asami, Y., Ogata, Y., Takagi, T., Kaji, S., Kawamoto, T., Ueda, Y., & Morioka, S. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00389-1 · Cited by 426
Cleland, C., Ferguson, S., Ellis, G., & Hunter, R. F. (2018) · BMC Medical Research Methodology · doi:10.1186/s12874-018-0642-3 · Cited by 407
Garin, O., Ayuso-Mateos, J. L., Almansa, J., Nieto, M., Chatterji, S., Vilagut, G., Alonso, J., Cieza, A., Svetskova, O., Burger, H., et al. (2010) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-8-51 · Cited by 425
Kotecha, A., Elsheikh, A., Roberts, C. R., Zhu, H., & Garway-Heath, D. F. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0557 · Cited by 423
Masson, L., MCNeill, G., Tomany, J., Simpson, J., Peace, H., Wei, L., Grubb, D., & Bolton-Smith, C. (2003) · Public Health Nutrition · doi:10.1079/phn2002429 · Cited by 423
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Visser, M., Fuerst, T., Lang, T., Salamone, L., Harris, T. B., Health, F. T., Absorptiometry, A., & Group, B. C. W. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.4.1513 · Cited by 422
Teicher, M. H., & Parigger, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0117423 · Cited by 421
Inoue, E., Yamanaka, H., Hara, M., Tomatsu, T., & Kamatani, N. (2007) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2006.054205 · Cited by 419
Fagerholm, P., Lagali, N. S., Merrett, K., Jackson, W. B., Munger, R., Liu, Y., Polarek, J. W., Söderqvist, M., & Griffith, M. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001022 · Cited by 420
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.014 · Cited by 423
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C. (2018) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 413
Coops, N. C., Tompalski, P., Goodbody, T. R. H., Queinnec, M., Luther, J. E., Bolton, D. K., White, J. C., Wulder, M. A., van Lier, O. R., & Hermosilla, T. (2021) · Remote Sensing of Environment · doi:10.1016/j.rse.2021.112477 · Cited by 406
Why Bland–Altman plots should use X, not (Y+X)/2 when X is a reference method
Krouwer, J. S. (2008) · Statistics in Medicine · doi:10.1002/sim.3086 · Cited by 415
Test-retest reliability of the Work Ability Index questionnaire
de Zwart, B. C. H. (2002) · Occupational Medicine · doi:10.1093/occmed/52.4.177 · Cited by 420
The relationship between EMG and change in thickness of transversus abdominis
McMeeken, J. M., Beith, I. D., Newham, D. J., Milligan, P., & Critchley, D. J. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.01.007 · Cited by 419
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Segmentation of blood vessels from red-free and fluorescein retinal images
Martinez-Perez, M. E., Hughes, A. D., Thom, S. A., Bharath, A. A., & Parker, K. H. (2007) · Medical Image Analysis · doi:10.1016/j.media.2006.11.004 · Cited by 416
Ward, L. C. (2019) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0335-3 · Cited by 417
A Vertical Jump Force Test for Assessing Bilateral Strength Asymmetry in Athletes
IMPELLIZZERI, F. M., RAMPININI, E., MAFFIULETTI, N., & MARCORA, S. M. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31814fb55c · Cited by 410
Antioxidant Activities and Oxidative Stress Byproducts in Human Hypertension
Redón, J., Oliva, M. R., Tormos, C., Giner, V., Chaves, J., Iradi, A., & Sáez, G. T. (2003) · Hypertension · doi:10.1161/01.hyp.0000068370.21009.38 · Cited by 420
Statistical Methods in Assessing Agreement: Models, Issues, and Tools
Lin, L., Hedayat, A. S., Sinha, B., & Yang, M. (2002) · Journal of the American Statistical Association · doi:10.1198/016214502753479392 · Cited by 413
Assessing intrarater, interrater, and test-retest reliability of continuous measurements
Rousson, V., Gasser, T., & Seifert, B. (2002) · Statistics in Medicine · doi:10.1002/sim.1253 · Cited by 415
Vagal modulation of heart rate during exercise: effects of age and physical fitness
Tulppo, M. P., Mäkikallio, T. H., Seppänen, T., Laukkanen, R. T., & Huikuri, H. V. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.2.h424 · Cited by 410
A review of the use of health status measures in economic evaluation.
Brazier, Deverill, Green, Harper, & Booth (1999) · Health Technology Assessment · doi:10.3310/hta3090 · Cited by 413
Statistics review 7: Correlation and regression.
Bewick, V., Cheek, L., & Ball, J. (2003) · Critical Care · doi:10.1186/cc2401 · Cited by 412
Respiration rate and volume measurements using wearable strain sensors
Chu, M., Nguyen, T., Pandey, V., Zhou, Y., Pham, H. N., Bar-Yoseph, R., Radom-Aizik, S., Jain, R., Cooper, D. M., & Khine, M. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0083-3 · Cited by 403
Bhutani, V. K., Gourley, G. R., Adler, S., Kreamer, B., Dalin, C., & Johnson, L. H. (2000) · Pediatrics · doi:10.1542/peds.106.2.e17 · Cited by 417
Griffanti, L., Zamboni, G., Khan, A., Li, L., Bonifacio, G., Sundaresan, V., Schulz, U. G., Kuker, W., Battaglini, M., Rothwell, P. M., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.07.018 · Cited by 414
Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivo
Svendsen, O., Haarbo, J., Hassager, C., & Christiansen, C. (1993) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/57.5.605 · Cited by 411
Diaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation
Vivier, E., Mekontso Dessap, A., Dimassi, S., Vargas, F., Lyazidi, A., Thille, A. W., & Brochard, L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2547-7 · Cited by 406
The Development, Assessment, and Selection of Questionnaires
PESUDOVS, K., BURR, J. M., HARLEY, C., & ELLIOTT, D. B. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e318141fe75 · Cited by 403
Vellante, M., Baron-Cohen, S., Melis, M., Marrone, M., Petretto, D. R., Masala, C., & Preti, A. (2013) · Cognitive Neuropsychiatry · doi:10.1080/13546805.2012.721728 · Cited by 406
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.