The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Abstract
Drug discovery is often impeded by the poor predictability of in vitro assays for drug toxicity. One primary reason for this observation is the inability to reproduce the pharmacokinetics (PK) of drugs in vitro. Mathematical models to predict the pharmacokinetics-pharmacodynamics (PK-PD) of drugs are available, but have several limitations, preventing broader application. A microscale cell culture analog (microCCA) is a microfluidic device based on a PK-PD model, where multiple cell culture chambers are connected with fluidic channels to mimic multi-organ interactions and test drug toxicity in a pharmacokinetic-based manner. One critical issue with microfluidics, including the microCCA, is that specialized techniques are required for assembly and operation, limiting its usability to non-experts. Here, we describe a novel design, with enhanced usability while allowing hydrogel-cell cultures of multiple types. Gravity-induced flow enables pumpless operation and prevents bubble formation. Three cell lines representing the liver, tumor and marrow were cultured in the three-chamber microCCA to test the toxicity of an anticancer drug, 5-fluorouracil. The result was analyzed with a PK-PD model of the device, and compared with the result in static conditions. Each cell type exhibited differential responses to 5-FU, and the responses in the microfluidic environment were different from those in static environment. Combination of a mathematical modeling approach (PK-PD modeling) and an in vitro experimental approach (microCCA) provides a novel platform with improved predictability for testing drug toxicity and can help researchers gain a better insight into the drug's mechanism of action.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Physiological Parameters in Laboratory Animals and Humans
Davies, B., & Morris, T. (1993) · Pharmaceutical Research · doi:10.1023/a:1018943613122 · Cited by 2,926
Wilkening, S., Stahl, F., & Bader, A. (2003) · Drug Metabolism and Disposition · doi:10.1124/dmd.31.8.1035 · Cited by 794
Clinical pharmacokinetics of 5-fluorouracil and its metabolites in plasma, urine, and bile.
Heggie, G. D., Sommadossi, J., Cross, D. S., Huster, W. J., & Diasio, R. B. (1987) · PubMed · Cited by 722
Role of Pharmacokinetics and Metabolism in Drug Discovery and Development
Lin, J. H., & Lu, A. Y. H. (1997) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01340-1 · Cited by 708
Physiologically Based Pharmacokinetic Modeling: Principles and Applications
Gerlowski, L. E., & Jain, R. K. (1983) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600721003 · Cited by 576
An update on in vitro test methods in human hepatic drug biotransformation research: pros and cons
Brandon, E. F. A., Raap, C. D., Meijerman, I., Beijnen, J. H., & Schellens, J. H. M. (2003) · Toxicology and Applied Pharmacology · doi:10.1016/s0041-008x(03)00128-5 · Cited by 567
Key factors in the rising cost of new drug discovery and development
Dickson, M., & Gagnon, J. P. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1382 · Cited by 498
Dihydropyrimidine dehydrogenase and the efficacy and toxicity of 5-fluorouracil
van Kuilenburg, A. B. P. (2004) · European Journal of Cancer · doi:10.1016/j.ejca.2003.12.004 · Cited by 488
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Self-citationModelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 563
Self-citationScreening out irrelevant cell-based models of disease
Horvath, P., Aulner, N., Bickle, M., Davies, A. M., Nery, E. D., Ebner, D., Montoya, M. C., Östling, P., Pietiäinen, V., Price, L. S., et al. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.175 · Cited by 525
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Self-citationOrgan-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435
Cell patterning technologies for organotypic tissue fabrication
Guillotin, B., & Guillemot, F. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.12.008 · Cited by 428
Microfluidics for single cell analysis
Yin, H., & Marshall, D. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.11.002 · Cited by 394
Microfluidic Devices for Drug Delivery Systems and Drug Screening
Damiati, S., Kompella, U. B., Damiati, S. A., & Kodzius, R. (2018) · Genes · doi:10.3390/genes9020103 · Cited by 383
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
Advances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies
Esch, M. B., King, T. L., & Shuler, M. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124629 · Cited by 328
Self-citationOrgan-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Organs-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Cell and tissue engineering for liver disease
Bhatia, S. N., Underhill, G. H., Zaret, K. S., & Fox, I. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3005975 · Cited by 309
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Engineering and physical sciences in oncology: challenges and opportunities
Mitchell, M. J., Jain, R. K., & Langer, R. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.83 · Cited by 273
Vernetti, L., Gough, A., Baetz, N., Blutt, S., Broughman, J. R., Brown, J. A., Foulke-Abel, J., Hasan, N., In, J., Kelly, E., et al. (2017) · Scientific Reports · doi:10.1038/srep42296 · Cited by 271
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Self-citationPumpless microfluidic platform for drug testing on human skin equivalents
Abaci, H. E., Gledhill, K., Guo, Z., Christiano, A. M., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c4lc00999a · Cited by 262
Self-citationOrgans-on-a-chip models for biological research
Vunjak-Novakovic, G., Ronaldson-Bouchard, K., & Radisic, M. (2021) · Cell · doi:10.1016/j.cell.2021.08.005 · Cited by 248
“The advantages of microfluidic multi-organ models support their continued development despite additional complexities (Sung et al., 2010).”
BackgroundOrgans-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Tsamandouras, N., Chen, W. L. K., Edington, C. D., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0122-4 · Cited by 222
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics
McAleer, C. W., Long, C. J., Elbrecht, D., Sasserath, T., Bridges, L. R., Rumsey, J. W., Martin, C., Schnepper, M., Wang, Y., Schuler, F., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav1386 · Cited by 199
Self-citationMicrofluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Baker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188
Satoh, T., Sugiura, S., Shin, K., Onuki-Nagasaki, R., Ishida, S., Kikuchi, K., Kakiki, M., & Kanamori, T. (2018) · Lab on a Chip · doi:10.1039/c7lc00952f · Cited by 181
Multi-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow
Esch, M. B., Prot, J.-M., Wang, Y. I., Miller, P., Llamas-Vidales, J. R., Naughton, B. A., Applegate, D. R., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c5lc00237k · Cited by 173
Self-citationIntegrated gut/liver microphysiological systems elucidates inflammatory inter‐tissue crosstalk
Chen, W. L. K., Edington, C., Suter, E., Yu, J., Velazquez, J. J., Velazquez, J. G., Shockley, M., Large, E. M., Venkataramanan, R., Hughes, D. J., et al. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26370 · Cited by 172
Unger, C., Kramer, N., Walzl, A., Scherzer, M., Hengstschläger, M., & Dolznig, H. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.10.015 · Cited by 158
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
An On-Chip Small Intestine–Liver Model for Pharmacokinetic Studies
Kimura, H., Ikeda, T., Nakayama, H., Sakai, Y., & Fujii, T. (2015) · SLAS Technology · doi:10.1177/2211068214557812 · Cited by 136
“Sung et al.(20) proposed micro cell culture analogs (microCCA) that can coculture two or more cell types in microfluidic devices to predict response to drugs and chemicals for establishment of a physiologically based pharmacokinetic (PBPK) model in silico.”
Background3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis
Kim, J.-Y., Fluri, D. A., Marchan, R., Boonen, K., Mohanty, S., Singh, P., Hammad, S., Landuyt, B., Hengstler, J. G., Kelm, J. M., et al. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.01.003 · Cited by 126
Applications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
Integrated heart/cancer on a chip to reproduce the side effects of anti-cancer drugs in vitro
Kamei, K.-I., Kato, Y., Hirai, Y., Ito, S., Satoh, J., Oka, A., Tsuchiya, T., Chen, Y., & Tabata, O. (2017) · RSC Advances · doi:10.1039/c7ra07716e · Cited by 113
Approaching the in vitro clinical trial: engineering organs on chips
Capulli, A. K., Tian, K., Mehandru, N., Bukhta, A., Choudhury, S. F., Suchyta, M., & Parker, K. K. (2014) · Lab on a Chip · doi:10.1039/c4lc00276h · Cited by 111
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
Next generation human skin constructs as advanced tools for drug development
Abaci, H., Guo, Z., Doucet, Y., Jacków, J., & Christiano, A. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217712690 · Cited by 104
Lee, J. B., & Sung, J. H. (2013) · Biotechnology Journal · doi:10.1002/biot.201300086 · Cited by 92
Self-citationProt, J. M., Maciel, L., Bricks, T., Merlier, F., Cotton, J., Paullier, P., Bois, F. Y., & Leclerc, E. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25232 · Cited by 90
Engineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
“modeled liver-tumor-marrow interactions using a microfluidic chip with cell lines and derived a PK model for the distribution of 5-fluorouracil [73].”
MethodMa, L., Barker, J., Zhou, C., Li, W., Zhang, J., Lin, B., Foltz, G., Küblbeck, J., & Honkakoski, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.02.054 · Cited by 83
Ozkan, A., Ghousifam, N., Hoopes, P. J., Yankeelov, T. E., & Rylander, M. N. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26919 · Cited by 73
Maass, C., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · Integrative Biology · doi:10.1039/c6ib00243a · Cited by 72
Sung, J. H., Wang, Y., & Shuler, M. L. (2019) · APL Bioengineering · doi:10.1063/1.5097675 · Cited by 66
Self-citationAdvances in Engineered Liver Models for Investigating Drug-Induced Liver Injury
Lin, C., & Khetani, S. R. (2016) · BioMed Research International · doi:10.1155/2016/1829148 · Cited by 66
Engineering Liver Microtissues for Disease Modeling and Regenerative Medicine
Huang, D. (., Gibeley, S. B., Xu, C., Xiao, Y., Celik, O., Ginsberg, H. N., & Leong, K. W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909553 · Cited by 65
Self-contained, low-cost Body-on-a-Chip systems for drug development
Wang, Y. I., Oleaga, C., Long, C. J., Esch, M. B., McAleer, C. W., Miller, P. G., Hickman, J. J., & Shuler, M. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217694101 · Cited by 59
Self-citationCritical Considerations for the Design of Multi-Organ Microphysiological Systems (MPS)
Malik, M., Yang, Y., Fathi, P., Mahler, G. J., & Esch, M. B. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.721338 · Cited by 43
Shinha, K., Nihei, W., Nakamura, H., Goto, T., Kawanishi, T., Ishida, N., Yamazaki, N., Imakura, Y., Mima, S., Inamura, K., et al. (2021) · Micromachines · doi:10.3390/mi12091007 · Cited by 36
Standard: human liver-on-a-chip
Liu, H., Zhang, X., Wang, Y., Zhang, M., Wang, P., Shang, J., Li, Z., Gong, L., Xie, X., Liu, D., et al. (2025) · Cell Regeneration · doi:10.1186/s13619-025-00226-0 · Cited by 12
Metadata
- Authors
- Sung, J. H., Kam, C., & Shuler, M. L.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 4
- Pages
- 446
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2112791462
- Cited by
- 484
- References
- 42
- FWCI
- 16.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.