The DOI matches its Crossref record; 141 of the 141 references it cites were found in a registry or an index.
Electrochemistry, biosensors and microfluidics: a convergence of fields
Abstract
This review catalogues the convergence of electrochemistry, biosensors, and microfluidics, with an emphasis on the emergence of new application areas. Image credit: Lisa Ngo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,435
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Electrochemical Quantitation of DNA Immobilized on Gold
Steel, A. B., Herne, T. M., & Tarlov, M. J. (1998) · Analytical Chemistry · doi:10.1021/ac980037q · Cited by 1,328
Electrochemical Impedance Spectroscopy
Chang, B.-Y., & Park, S.-M. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.012809.102211 · Cited by 1,248
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Ultrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Digital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Fan, C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1633515100 · Cited by 1,043
Manz, A., Harrison, D. J., Verpoorte, E. M. J., Fettinger, J. C., Paulus, A., Lüdi, H., & Widmer, H. M. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80293-4 · Cited by 1,042
Borisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Baret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Electrochemical Biosensors: Recommended Definitions and Classification
Thevenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S. (1999) · Pure and Applied Chemistry · doi:10.1351/pac199971122333 · Cited by 909
Ellington, A. D., & Szostak, J. W. (1992) · Nature · doi:10.1038/355850a0 · Cited by 856
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Self-citationA perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
Micro- and Nanoscale Fluid Mechanics: Transport in Microfluidic Devices
Kirby, B. J. (2010) · Cited by 753
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Quantitative assessment of single-cell RNA-sequencing methods
Wu, A. R., Neff, N. F., Kalisky, T., Dalerba, P., Treutlein, B., Rothenberg, M. E., Mburu, F. M., Mantalas, G. L., Sim, S., Clarke, M. F., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2694 · Cited by 696
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
Schmickler, W., & Santos, E. (2010) · Springer eBooks · doi:10.1007/978-3-642-04937-8 · Cited by 668
Commercial quartz crystal microbalances – theory and applications
O’Sullivan, C. K., & Guilbault, G. G. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00040-8 · Cited by 658
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Long‐Range Electrical Contacting of Redox Enzymes by SWCNT Connectors
Patolsky, F., Weizmann, Y., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353275 · Cited by 609
Advances in biosensors: Principle, architecture and applications
Perumal, V., & Hashim, U. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.jab.2013.02.001 · Cited by 606
Long-Term Monitoring of Bacteria Undergoing Programmed Population Control in a Microchemostat
Balagaddé, F. K., You, L., Hansen, C. L., Arnold, F. H., & Quake, S. R. (2005) · Science · doi:10.1126/science.1109173 · Cited by 599
Kratz (2004) · doi:10.1056/nejmcpc049016 · Cited by 593
Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors
Delaney, J. L., Hogan, C. F., Tian, J., & Shen, W. (2011) · Analytical Chemistry · doi:10.1021/ac102392t · Cited by 592
Xiao, Y., Piorek, B. D., Plaxco, K. W., & Heeger, A. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja056555h · Cited by 527
High-throughput injection with microfluidics using picoinjectors
Abate, A. R., Hung, T., Mary, P., Agresti, J. J., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006888107 · Cited by 502
Single-base mismatch detection based on charge transduction through DNA
Kelley, S. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.24.4830 · Cited by 495
Integration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Surface plasmon resonance based biosensor technique: A review
Guo, X. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200015 · Cited by 436
Surface plasmon resonance imaging for affinity-based biosensors
Scarano, S., Mascini, M., Turner, A. P. F., & Minunni, M. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.039 · Cited by 426
Fu, Y. Q., Luo, J. K., Du, X. Y., Flewitt, A. J., Li, Y., Markx, G. H., Walton, A. J., & Milne, W. I. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.10.010 · Cited by 419
Flexographically Printed Fluidic Structures in Paper
Olkkonen, J., Lehtinen, K., & Erho, T. (2010) · Analytical Chemistry · doi:10.1021/ac1027066 · Cited by 369
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Lin, P., Luo, X., Hsing, I., & Yan, F. (2011) · Advanced Materials · doi:10.1002/adma.201102017 · Cited by 346
Electrochemical Sensors, Biosensors and their Biomedical Applications
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373738-0.x5001-6 · Cited by 333
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Putting Electrowetting to Work
Wheeler, A. R. (2008) · Science · doi:10.1126/science.1165719 · Cited by 315
Self-citationOscillographic Polarography of Highly Polymerized Deoxyribonucleic Acid
PALEČEK, E. (1960) · Nature · doi:10.1038/188656a0 · Cited by 315
Heterogeneous immunoassays using magnetic beads on a digital microfluidic platform
Sista, R. S., Eckhardt, A. E., Srinivasan, V., Pollack, M. G., Palanki, S., & Pamula, V. K. (2008) · Lab on a Chip · doi:10.1039/b807855f · Cited by 294
Mell, L. D., & Maloy, J. T. (1975) · Analytical Chemistry · doi:10.1021/ac60352a006 · Cited by 292
3D printed microfluidic devices with integrated versatile and reusable electrodes
Erkal, J. L., Selimovic, A., Gross, B. C., Lockwood, S. Y., Walton, E. L., McNamara, S., Martin, R. S., & Spence, D. M. (2014) · Lab Chip · doi:10.1039/c4lc00171k · Cited by 287
Xiang, Y., Lu, S., & Jiang, S. P. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35048c · Cited by 277
Mayer, M. T., Lin, Y., Yuan, G., & Wang, D. (2013) · Accounts of Chemical Research · doi:10.1021/ar300302z · Cited by 271
The electrochemical reduction processes of solid compounds in high temperature molten salts
Xiao, W., & Wang, D. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60327j · Cited by 255
Electronic Detection of Nucleic Acids
Umek, R. M., Lin, S. W., Vielmetter, J., Terbrueggen, R. H., Irvine, B., Yu, C. J., Kayyem, J. F., Yowanto, H., Blackburn, G. F., Farkas, D. H., et al. (2001) · The Journal of Molecular Diagnostics · doi:10.1016/s1525-1578(10)60655-1 · Cited by 253
Xiao, Y., Lubin, A. A., Baker, B. R., Plaxco, K. W., & Heeger, A. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607693103 · Cited by 237
Apilux, A., Ukita, Y., Chikae, M., Chailapakul, O., & Takamura, Y. (2013) · Lab Chip · doi:10.1039/c2lc40690j · Cited by 230
Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface
Long, Z., Shetty, A. M., Solomon, M. J., & Larson, R. G. (2009) · Lab on a Chip · doi:10.1039/b819818g · Cited by 220
Fobel, R., Fobel, C., & Wheeler, A. R. (2013) · Applied Physics Letters · doi:10.1063/1.4807118 · Cited by 218
Self-citationShiroma, L. Y., Santhiago, M., Gobbi, A. L., & Kubota, L. T. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.011 · Cited by 217
Programmable large area digital microfluidic array with integrated droplet sensing for bioassays
Hadwen, B., Broder, G. R., Morganti, D., Jacobs, A., Brown, C., Hector, J. R., Kubota, Y., & Morgan, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40273d · Cited by 211
Zayats, M., Katz, E., Baron, R., & Willner, I. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052841h · Cited by 210
Chen, K., & Hugh Fan, Z. (2016) · Circulating Tumor Cells · doi:10.1002/9781119244554.ch2 · Cited by 200
An ultrasensitive universal detector based on neutralizer displacement
Das, J., Cederquist, K. B., Zaragoza, A. A., Lee, P. E., Sargent, E. H., & Kelley, S. O. (2012) · Nature Chemistry · doi:10.1038/nchem.1367 · Cited by 199
A microdroplet dilutor for high-throughput screening
Niu, X., Gielen, F., Edel, J. B., & deMello, A. J. (2011) · Nature Chemistry · doi:10.1038/nchem.1046 · Cited by 199
Sol-gel vanadium pentaoxide glucose biosensor
Glezer, V., & Lev, O. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00059a072 · Cited by 191
Digital Microfluidic Magnetic Separation for Particle-Based Immunoassays
Ng, A. H. C., Choi, K., Luoma, R. P., Robinson, J. M., & Wheeler, A. R. (2012) · Analytical Chemistry · doi:10.1021/ac3020627 · Cited by 187
Self-citationNewman, J. D., & Setford, S. J. (2006) · Molecular Biotechnology · doi:10.1385/mb:32:3:249 · Cited by 180
Viswanathan, S., Rani, C., Vijay Anand, A., & Ho, J.-A. A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.006 · Cited by 167
de la Escosura‐Muñiz, A., & Merkoçi, A. (2011) · Small · doi:10.1002/smll.201002349 · Cited by 153
Active Digital Microfluidic Paper Chips with Inkjet‐Printed Patterned Electrodes
Ko, H., Lee, J., Kim, Y.-J., Lee, B., Jung, C., Choi, J., Kwon, O., & Shin, K. (2014) · Advanced Materials · doi:10.1002/adma.201305014 · Cited by 152
Choi, K., Ng, A. H. C., Fobel, R., Chang-Yen, D. A., Yarnell, L. E., Pearson, E., Oleksak, C. M., Fischer, A. T., Luoma, R. P., Robinson, J. M., et al. (2013) · Analytical Chemistry · doi:10.1021/ac401847x · Cited by 148
Self-citationPaper‐Based Electrochemical Biosensors: From Test Strips to Paper‐Based Microfluidics
Liu, B., Du, D., Hua, X., Yu, X., & Lin, Y. (2014) · Electroanalysis · doi:10.1002/elan.201400036 · Cited by 147
Malic, L., Veres, T., & Tabrizian, M. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.11.031 · Cited by 144
Single-sided continuous optoelectrowetting (SCOEW) for droplet manipulation with light patterns
Park, S.-Y., Teitell, M. A., & Chiou, E. P. Y. (2010) · Lab on a Chip · doi:10.1039/c001324b · Cited by 142
Liu, Y., Kwa, T., & Revzin, A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.089 · Cited by 141
Maze exploration and learning in C. elegans
Qin, J., & Wheeler, A. R. (2006) · Lab on a Chip · doi:10.1039/b613414a · Cited by 140
Self-citationPaper Microfluidics Goes Digital
Fobel, R., Kirby, A. E., Ng, A. H. C., Farnood, R., & Wheeler, A. R. (2014) · Advanced Materials · doi:10.1002/adma.201305168 · Cited by 140
Self-citationA digital microfluidic electrochemical immunoassay
Shamsi, M. H., Choi, K., Ng, A. H. C., & Wheeler, A. R. (2013) · Lab on a Chip · doi:10.1039/c3lc51063h · Cited by 128
Self-citationMicrofluidic platforms: a mainstream technology for the preparation of crystals
Puigmartí‐Luis, J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60372e · Cited by 126
Electromechanical model for actuating liquids in a two-plate droplet microfluidic device
Chatterjee, D., Shepherd, H., & Garrell, R. L. (2009) · Lab on a Chip · doi:10.1039/b901375j · Cited by 125
Electrocatalytic Detection of Pathogenic DNA Sequences and Antibiotic Resistance Markers
Lapierre-Devlin, M. A., O’Keefe, M., Taft, B. J., & Kelley, S. O. (2003) · Analytical Chemistry · doi:10.1021/ac0349429 · Cited by 120
A digital microfluidic method for dried blood spot analysis
Jebrail, M. J., Yang, H., Mudrik, J. M., Lafrenière, N. M., McRoberts, C., Al-Dirbashi, O. Y., Fisher, L., Chakraborty, P. K., & Wheeler, A. R. (2011) · Lab on a Chip · doi:10.1039/c1lc20524b · Cited by 120
Self-citationBiosensors: Theory and applications
Scott, A. O. (1994) · Trends in Food Science & Technology · doi:10.1016/0924-2244(94)90110-4 · Cited by 111
Soleymani, L., Fang, Z., Sun, X., Yang, H. Y., Taft, B. J., Sargent, E. H., & Kelley, S. O. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902439 · Cited by 99
Eydelnant, I. A., Li, B. ‘., & Wheeler, A. R. (2014) · Nature Communications · doi:10.1038/ncomms4355 · Cited by 99
Self-citationDroplet-Scale Estrogen Assays in Breast Tissue, Blood, and Serum
Mousa, N. A., Jebrail, M. J., Yang, H., Abdelgawad, M. O., Metalnikov, P. S., Chen, J., Wheeler, A. R., & Casper, R. F. (2009) · Science Translational Medicine · doi:10.1126/scitranslmed.3000105 · Cited by 98
Self-citationKuznetsov, B. A., Shumakovich, G. P., Королева, О. В., & Yaropolov, A. I. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00135-4 · Cited by 93
Cheng, X. R., Hau, B. Y. H., Endo, T., & Kerman, K. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.003 · Cited by 90
Solving Mazes Using Microfluidic Networks
Fuerstman, M. J., Deschatelets, P., Kane, R. S., Schwartz, A., Kenis, P. J. A., Deutch, J. M., & Whitesides, G. M. (2003) · Langmuir · doi:10.1021/la030054x · Cited by 87
Flow-enhanced electrochemical immunosensors on centrifugal microfluidic platforms
Kim, T.-H., Abi‐Samra, K., Sunkara, V., Park, D.-K., Amasia, M., Kim, N., Kim, J. T., Kim, H., Madou, M. J., & Cho, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50374g · Cited by 85
Microfluidic immunosensor design for the quantification of interleukin-6 in human serum samples
Messina, G. A., Panini, N. V., Martínez, N. A., & Raba, J. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.05.055 · Cited by 76
Persat, A., & Santiago, J. G. (2011) · Analytical Chemistry · doi:10.1021/ac103225c · Cited by 76
Matharu, Z., Patel, D., Gao, Y., Haque, A., Zhou, Q., & Revzin, A. (2014) · Analytical Chemistry · doi:10.1021/ac502383e · Cited by 75
Arata, H. F., Komatsu, H., Hosokawa, K., & Maeda, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048329 · Cited by 73
Chikkaveeraiah, B. V., Liu, H., Mani, V., Papadimitrakopoulos, F., & Rusling, J. F. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.02.002 · Cited by 70
Wang, Y., Li, C., Li, X., Li, Y., & Kraatz, H. (2008) · Analytical Chemistry · doi:10.1021/ac7024688 · Cited by 68
Tuning the Bacterial Detection Sensitivity of Nanostructured Microelectrodes
Das, J., & Kelley, S. O. (2013) · Analytical Chemistry · doi:10.1021/ac401221f · Cited by 67
Lam, B., Fang, Z., Sargent, E. H., & Kelley, S. O. (2011) · Analytical Chemistry · doi:10.1021/ac202599b · Cited by 65
Nanostructured substrates for portable and miniature SPR biosensors
Breault-Turcot, J., & Masson, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5963-1 · Cited by 60
Matharu, Z., Enomoto, J., & Revzin, A. (2012) · Analytical Chemistry · doi:10.1021/ac3025619 · Cited by 57
Microfluidic systems for studying neurotransmitters and neurotransmission
Croushore, C. A., & Sweedler, J. V. (2013) · Lab on a Chip · doi:10.1039/c3lc41334a · Cited by 55
Fischer, D. J., Hulvey, M. K., Regel, A. R., & Lunte, S. M. (2009) · Electrophoresis · doi:10.1002/elps.200900317 · Cited by 55
Integrated Digital Microfluidic Platform for Voltammetric Analysis
Dryden, M. D. M., Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2013) · Analytical Chemistry · doi:10.1021/ac402003v · Cited by 55
Self-citationIvanov, I., Stojcic, J., Stanimirovic, A., Sargent, E. H., Nam, R. K., & Kelley, S. O. (2012) · Analytical Chemistry · doi:10.1021/ac3029739 · Cited by 53
Tan, S. H., Maes, F., Semin, B., Vrignon, J., & Baret, J. (2014) · Scientific Reports · doi:10.1038/srep04787 · Cited by 51
High-Sensitivity C-Reactive Protein Methods Examined
Kos, S., Schmitz, M. P., Bekers, O., Menheere, P. P. C. A., & van Dieijen‐Visser, M. P. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.2.359 · Cited by 44
Proximal Bacterial Lysis and Detection in Nanoliter Wells Using Electrochemistry
Besant, J. D., Das, J., Sargent, E. H., & Kelley, S. O. (2013) · ACS Nano · doi:10.1021/nn4035298 · Cited by 43
The Business of Self-Monitoring of Blood Glucose: A Market Profile
Hughes, M. D. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300530 · Cited by 41
Electrochemical biosensors for on-chip detection of oxidative stress from immune cells
Yan, J., Pedrosa, V. A., Enomoto, J., Simonian, A. L., & Revzin, A. (2011) · Biomicrofluidics · doi:10.1063/1.3624739 · Cited by 40
Parallel-plate lab-on-a-chip based on digital microfluidics for on-chip electrochemical analysis
Yu, Y., Chen, J., & Zhou, J. H. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/1/015020 · Cited by 39
Nanostructured biomolecular detectors: pushing performance at the nanoscale
Cederquist, K. B., & Kelley, S. O. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.04.011 · Cited by 36
Reconfigurable microfluidics with integrated aptasensors for monitoring intercellular communication
Kwa, T., Zhou, Q., Gao, Y., Rahimian, A., Kwon, L., Liu, Y., & Revzin, A. (2014) · Lab on a Chip · doi:10.1039/c4lc00037d · Cited by 32
Ges, I. A., Brindley, R. L., Currie, K., & Baudenbacher, F. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50779c · Cited by 30
Flow biosensing and sampling in indirect electrochemical detection
Lamberti, F., Luni, C., Zambon, A., Serra, P. A., Giomo, M., & Elvassore, N. (2012) · Biomicrofluidics · doi:10.1063/1.4705368 · Cited by 25
Gunasekara, D. B., Hulvey, M. K., Lunte, S. M., & da Silva, J. A. F. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5810-4 · Cited by 24
Wu, R., Yang, C., Cheing, C., & Tseng, F. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0049 · Cited by 12
Electrode Placement and Fluid Flow Rates in Microfluidic Electrochemical Devices
Dydek, E. V., Petersen, M. V., Nocera, D. G., & Jensen, K. F. (2012) · Journal of The Electrochemical Society · doi:10.1149/2.007211jes · Cited by 9
Cited by
Influence of Bubbles on the Energy Conversion Efficiency of Electrochemical Reactors
Angulo, A., van der Linde, P., Gardeniers, H., Modestino, M., & Fernández Rivas, D. (2020) · Joule · doi:10.1016/j.joule.2020.01.005 · Cited by 958
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Electrochemical immunosensors – A powerful tool for analytical applications
Felix, F. S., & Angnes, L. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.029 · Cited by 599
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Metadata
- Authors
- Rackus, D. G., Shamsi, M. H., & Wheeler, A. R.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 44
- Issue
- 15
- Pages
- 5320-5340
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2156955950
- Cited by
- 354
- References
- 141
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.