Recent advances in microfluidic technologies for cell-to-cell interaction studies
Open accessThe DOI matches its Crossref record; 163 of the 163 references it cites were found in a registry or an index.
Abstract
Microfluidic cell cultures are ideally positioned to become the next generation of in vitro diagnostic tools for biomedical research, where key biological processes such as cell signalling and dynamic cell-to-cell interactions can be reliably analysed under reproducible physiological cell culture conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By incorporating organoids into a micro fl uidic device, organoids-ona-chip inherit the combined bene fi ts of both micro fl uidics and 3D organoid models, thus providing a unique way to study tumor -stroma interactions and their systemic effects [69,74 -76].”
From 3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions (2021) · cites this paper as [76]
In the citing paper
“Through precise microfluidic designs, microfluidic devices can reconstruct physiological dynamic characteristics in tissues, such as physiological flow, shear stress, nutrient delivery, and drug action, in a controllable environment, providing a platform for cell culture, microenvironment creation, and organ simulation or in vitro assessment of organ tissue60–67.”
From Tumor-on-a-chip: from bioinspired design to biomedical application (2021) · cites this paper as [67]
In the citing paper
“A 3D coculture model of tumor spheroids has been developed to study different in vitro cancer types, such as lung and salivary gland cancers, as well as invasion and extravasation, as cell migration leads to infiltration and extravasation events during metastasis (Fig. 4)67,174.”
From Tumor-on-a-chip: from bioinspired design to biomedical application (2021) · cites this paper as [67]
Citations
Cites
Angiogenesis in cancer and other diseases
Carmeliet, P., & Jain, R. K. (2000) · Nature · doi:10.1038/35025220 · Cited by 9,070
Oxidative stress, inflammation, and cancer: How are they linked?
Reuter, S., Gupta, S. C., Chaturvedi, M. M., & Aggarwal, B. B. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2010.09.006 · Cited by 5,441
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Modeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
The cell. A molecular approach
Vella, F. (1998) · Biochemical Education · doi:10.1016/s0307-4412(98)00065-x · Cited by 1,189
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Manz, A., Harrison, D. J., Verpoorte, E. M. J., Fettinger, J. C., Paulus, A., Lüdi, H., & Widmer, H. M. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80293-4 · Cited by 1,042
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
Cell interactions with three-dimensional matrices
Cukierman, E., Pankov, R., & Yamada, K. M. (2002) · Current Opinion in Cell Biology · doi:10.1016/s0955-0674(02)00364-2 · Cited by 889
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment
Jang, K.-J., Mehr, A. P., Hamilton, G. A., McPartlin, L. A., Chung, S., Suh, K.-Y., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40049b · Cited by 849
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels
Shin, Y., Han, S., Jeon, J. S., Yamamoto, K., Zervantonakis, I. K., Sudo, R., Kamm, R. D., & Chung, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.051 · Cited by 617
Three-dimensional manipulation of single cells using surface acoustic waves
Guo, F., Mao, Z., Chen, Y., Xie, Z., Lata, J. P., Li, P., Ren, L., Liu, J., Yang, J., Dao, M., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1524813113 · Cited by 594
Microfluidic control of cell pairing and fusion
Skelley, A. M., Kirak, O., Suh, H., Jaenisch, R., & Voldman, J. (2009) · Nature Methods · doi:10.1038/nmeth.1290 · Cited by 571
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
A microfluidic 3D in vitro model for specificity of breast cancer metastasis to bone
Bersini, S., Jeon, J. S., Dubini, G., Arrigoni, C., Chung, S., Charest, J. L., Moretti, M., & Kamm, R. D. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.050 · Cited by 534
GUGUENGUILLOUZO, C., CLEMENT, B., BAFFET, G., BEAUMONT, C., MORELCHANY, E., GLAISE, D., & GUILLOUZO, A. (1983) · Experimental Cell Research · doi:10.1016/0014-4827(83)90107-6 · Cited by 519
Large-Scale Single-Cell Trapping And Imaging Using Microwell Arrays
Rettig, J. R., & Folch, A. (2005) · Analytical Chemistry · doi:10.1021/ac0505977 · Cited by 502
A multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
Biomimetic model to reconstitute angiogenic sprouting morphogenesis in vitro
Nguyen, D.-H. T., Stapleton, S. C., Yang, M. T., Cha, S. S., Choi, C. K., Galie, P. A., & Chen, C. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221526110 · Cited by 493
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Fabrication of microfluidic hydrogels using molded gelatin as a sacrificial element
Golden, A. P., & Tien, J. (2007) · Lab on a Chip · doi:10.1039/b618409j · Cited by 479
Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476
Chemotherapy-induced antitumor immunity requires formyl peptide receptor 1
Vacchelli, E., Ma, Y., Baracco, E. E., Sistigu, A., Enot, D. P., Pietrocola, F., Yang, H., Adjemian, S., Chaba, K., Semeraro, M., et al. (2015) · Science · doi:10.1126/science.aad0779 · Cited by 452
Marsano, A., Conficconi, C., Lemme, M., Occhetta, P., Gaudiello, E., Votta, E., Cerino, G., Redaelli, A., & Rasponi, M. (2016) · Lab on a Chip · doi:10.1039/c5lc01356a · Cited by 447
Perfused multiwell plate for 3D liver tissue engineering
Domansky, K., Inman, W., Serdy, J., Dash, A., Lim, M. H. M., & Griffith, L. G. (2010) · Lab Chip · doi:10.1039/b913221j · Cited by 444
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
In Vitro Perfused Human Capillary Networks
Moya, M. L., Hsu, Y.-H., Lee, A. P., Hughes, C. C. W., & George, S. C. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0430 · Cited by 387
Reconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis
Frey, O., Misun, P. M., Fluri, D. A., Hengstler, J. G., & Hierlemann, A. (2014) · Nature Communications · doi:10.1038/ncomms5250 · Cited by 387
3D microtumors in vitro supported by perfused vascular networks
Sobrino, A., Phan, D. T. T., Datta, R., Wang, X., Hachey, S. J., Romero-López, M., Gratton, E., Lee, A. P., George, S. C., & Hughes, C. C. W. (2016) · Scientific Reports · doi:10.1038/srep31589 · Cited by 387
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Sin, A., Chin, K. C., Jamil, M. F., Kostov, Y., Rao, G., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp034077d · Cited by 368
Differential effects of equiaxial and uniaxial strain on mesenchymal stem cells
Park, J. S., Chu, J. S. F., Cheng, C., Chen, F., Chen, D., & Li, S. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20250 · Cited by 342
Simmons, C. A., Matlis, S., Thornton, A. J., Chen, S., Wang, C.-Y., & Mooney, D. J. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00110-6 · Cited by 310
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Xu, Z., Gao, Y., Hao, Y., Li, E., Wang, Y., Zhang, J., Wang, W., Gao, Z., & Wang, Q. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.045 · Cited by 295
Microfluidic Local Perfusion Chambers for the Visualization and Manipulation of Synapses
Taylor, A. M., Dieterich, D. C., Ito, H. T., Kim, S. A., & Schuman, E. M. (2010) · Neuron · doi:10.1016/j.neuron.2010.03.022 · Cited by 292
Placenta-on-a-chip: a novel platform to study the biology of the human placenta
Lee, J. S., Romero, R., Han, Y. M., Kim, H. C., Kim, C. J., Hong, J.-S., & Huh, D. (2016) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2015.1038518 · Cited by 273
Development of a microphysiological model of human kidney proximal tubule function
Weber, E. J., Chapron, A., Chapron, B. D., Voellinger, J. L., Lidberg, K. A., Yeung, C. K., Wang, Z., Yamaura, Y., Hailey, D. W., Neumann, T., et al. (2016) · Kidney International · doi:10.1016/j.kint.2016.06.011 · Cited by 272
Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00412e · Cited by 266
Microfluidics—downsizing large-scale biology
Mitchell, P. (2001) · Nature Biotechnology · doi:10.1038/90754 · Cited by 264
A microphysiological model of the human placental barrier
Blundell, C., Tess, E. R., Schanzer, A. S. R., Coutifaris, C., Su, E. J., Parry, S., & Huh, D. (2016) · Lab on a Chip · doi:10.1039/c6lc00259e · Cited by 252
Control of Perfusable Microvascular Network Morphology Using a Multiculture Microfluidic System
Whisler, J. A., Chen, M. B., & Kamm, R. D. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2013.0370 · Cited by 242
A 3D microfluidic model for preclinical evaluation of TCR-engineered T cells against solid tumors
Pavesi, A., Tan, A. T., Koh, S., Chia, A., Colombo, M., Antonecchia, E., Miccolis, C., Ceccarello, E., Adriani, G., Raimondi, M. T., et al. (2017) · JCI Insight · doi:10.1172/jci.insight.89762 · Cited by 241
Sung, K. E., Yang, N., Pehlke, C., Keely, P. J., Eliceiri, K. W., Friedl, A., & Beebe, D. J. (2011) · Integr. Biol. · doi:10.1039/c0ib00063a · Cited by 226
Flow Cytometry of Escherichia coli on Microfluidic Devices
McClain, M. A., Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M. (2001) · Analytical Chemistry · doi:10.1021/ac010504v · Cited by 224
A microengineered pathophysiological model of early-stage breast cancer
Choi, Y., Hyun, E., Seo, J., Blundell, C., Kim, H. C., Lee, E., Lee, S. H., Moon, A., Moon, W. K., & Huh, D. (2015) · Lab on a Chip · doi:10.1039/c5lc00514k · Cited by 222
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
A three-dimensional in vitro model of tumor cell intravasation
Ehsan, S. M., Welch-Reardon, K. M., Waterman, M. L., Hughes, C. C. W., & George, S. C. (2014) · Integrative Biology · doi:10.1039/c3ib40170g · Cited by 196
Baker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188
A microfluidic-based platform for tumour spheroid culture, monitoring and drug screening
Kwapiszewska, K., Michalczuk, A., Rybka, M., Kwapiszewski, R., & Brzózka, Z. (2014) · Lab Chip · doi:10.1039/c4lc00291a · Cited by 184
Parlato, S., De Ninno, A., Molfetta, R., Toschi, E., Salerno, D., Mencattini, A., Romagnoli, G., Fragale, A., Roccazzello, L., Buoncervello, M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-01013-x · Cited by 181
Integrating biological vasculature into a multi-organ-chip microsystem
Schimek, K., Busek, M., Brincker, S., Groth, B., Hoffmann, S., Lauster, R., Lindner, G., Lorenz, A., Menzel, U., Sonntag, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50217a · Cited by 180
Yeon, J. H., Ryu, H. R., Chung, M., Hu, Q. P., & Jeon, N. L. (2012) · Lab on a Chip · doi:10.1039/c2lc40131b · Cited by 179
3D-printed devices for continuous-flow organic chemistry
Dragone, V., Sans, V., Rosnes, M. H., Kitson, P. J., & Cronin, L. (2013) · Beilstein Journal of Organic Chemistry · doi:10.3762/bjoc.9.109 · Cited by 174
Imura, Y., Sato, K., & Yoshimura, E. (2010) · Analytical Chemistry · doi:10.1021/ac100806x · Cited by 172
Hofer, D. R., Sherwood, E. R., Bromberg, W. D., Mendelsohn, J. M., Lee, C., & Kozlowski, J. M. (1991) · PubMed · Cited by 167
Misun, P. M., Rothe, J., Schmid, Y. R. F., Hierlemann, A., & Frey, O. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.22 · Cited by 167
Kang, Y. B. (., Sodunke, T. R., Lamontagne, J., Cirillo, J., Rajiv, C., Bouchard, M. J., & Noh, M. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25659 · Cited by 165
Liu, T., Lin, B., & Qin, J. (2010) · Lab on a Chip · doi:10.1039/c000022a · Cited by 162
Cross talk between cancer and immune cells: exploring complex dynamics in a microfluidic environment
Businaro, L., De Ninno, A., Schiavoni, G., Lucarini, V., Ciasca, G., Gerardino, A., Belardelli, F., Gabriele, L., & Mattei, F. (2013) · Lab Chip · doi:10.1039/c2lc40887b · Cited by 162
van der Meer, A. D., Orlova, V. V., ten Dijke, P., van den Berg, A., & Mummery, C. L. (2013) · Lab on a Chip · doi:10.1039/c3lc50435b · Cited by 150
Over a century of neuron culture: from the hanging drop to microfluidic devices.
Millet, L. J., & Gillette, M. U. (2012) · PubMed Central · Cited by 147
Buchanan, C. F., Voigt, E. E., Szot, C. S., Freeman, J. W., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0731 · Cited by 143
Block-Cell-Printing for live single-cell printing
Zhang, K., Chou, C.-K., Xia, X., Hung, M.-C., & Qin, L. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1313661111 · Cited by 142
Zahavi, E. E., Ionescu, A., Gluska, S., Gradus, T., Ben‐Yaakov, K., & Perlson, E. (2015) · Journal of Cell Science · doi:10.1242/jcs.167544 · Cited by 138
Emergent Functional Properties of Neuronal Networks with Controlled Topology
Marconi, E., Nieus, T. R., Maccione, A., Valente, P., Simi, A., Messa, M., Dante, S., Baldelli, P., Berdondini, L., & Benfenati, F. (2012) · PLoS ONE · doi:10.1371/journal.pone.0034648 · Cited by 134
Live-Cell Imaging of Invasion and Intravasation in an Artificial Microvessel Platform
Wong, A. D., & Searson, P. C. (2014) · Cancer Research · doi:10.1158/0008-5472.can-14-1042 · Cited by 132
Engineering opportunities in cancer immunotherapy
Jeanbart, L., & Swartz, M. A. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508516112 · Cited by 132
Huang, Y., Williams, J. C., & Johnson, S. M. (2012) · Lab on a Chip · doi:10.1039/c2lc21142d · Cited by 130
Sticker, D., Rothbauer, M., Lechner, S., Hehenberger, M.-T., & Ertl, P. (2015) · Lab on a Chip · doi:10.1039/c5lc01028d · Cited by 129
Self-citationBrain microvascular endothelial cells resist elongation due to curvature and shear stress
Ye, M., Sanchez, H. M., Hultz, M., Yang, Z., Bogorad, M., Wong, A. D., & Searson, P. C. (2014) · Scientific Reports · doi:10.1038/srep04681 · Cited by 129
McMahon, L. A., Reid, A. J., Campbell, V. A., & Prendergast, P. J. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9416-5 · Cited by 129
Mechanical stimulation of epithelial cells using polypyrrole microactuators
Svennersten, K., Berggren, M., Richter‐Dahlfors, A., & Jager, E. W. H. (2011) · Lab on a Chip · doi:10.1039/c1lc20436j · Cited by 124
Shi, M., Majumdar, D., Gao, Y., Brewer, B. M., Goodwin, C. R., McLean, J. A., Li, D., & Webb, D. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50249j · Cited by 122
Single-cell level co-culture platform for intercellular communication
Hong, S., Pan, Q., & Lee, L. P. (2012) · Integrative Biology · doi:10.1039/c2ib00166g · Cited by 122
Co-culture of neurons and glia in a novel microfluidic platform
Majumdar, D., Gao, Y., Li, D., & Webb, D. J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.024 · Cited by 121
Organs-on-a-chip for drug discovery
Selimović, Š., Dokmeci, M. R., & Khademhosseini, A. (2013) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2013.06.005 · Cited by 113
Li, A. P., Bode, C., & Sakai, Y. (2004) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2004.09.010 · Cited by 112
Tissue-engineered microenvironment systems for modeling human vasculature
Tourovskaia, A., Fauver, M., Kramer, G., Simonson, S., & Neumann, T. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214539228 · Cited by 109
Optical and electrochemical detection techniques for cell-based microfluidic systems
Yi, C., Zhang, Q., Li, C., Yang, J., Zhao, J., & Yang, M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0252-x · Cited by 106
Gao, Y., Majumdar, D., Jovanovic, B., Shaifer, C., Lin, P. C., Zijlstra, A., Webb, D. J., & Li, D. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9523-9 · Cited by 103
Fiorini, G. S., Jeffries, G. D. M., Lim, D. S. W., Kuyper, C. L., & Chiu, D. T. (2003) · Lab on a Chip · doi:10.1039/b305074m · Cited by 102
Rapid Prototyping of Thermoset Polyester Microfluidic Devices
Fiorini, G. S., Lorenz, R. M., Kuo, J. S., & Chiu, D. T. (2004) · Analytical Chemistry · doi:10.1021/ac0498922 · Cited by 102
Berdondini, L., Chiappalone, M., van der Wal, P. D., Imfeld, K., de Rooij, N. F., Koudelka‐Hep, M., Tedesco, M., Martinoia, S., van Pelt, J., Masson, G. L., et al. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.04.042 · Cited by 100
Micro-scale and microfluidic devices for neurobiology
Taylor, A. M., & Jeon, N. L. (2010) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2010.07.011 · Cited by 100
Microfluidic oxygen imaging using integrated optical sensor layers and a color camera
Ungerböck, B., Charwat, V., Ertl, P., & Mayr, T. (2013) · Lab on a Chip · doi:10.1039/c3lc41315b · Cited by 96
Self-citationCancer-driven dynamics of immune cells in a microfluidic environment
Agliari, E., Biselli, E., De Ninno, A., Schiavoni, G., Gabriele, L., Gerardino, A., Mattei, F., Barra, A., & Businaro, L. (2014) · Scientific Reports · doi:10.1038/srep06639 · Cited by 91
Multi-compartment neuron–glia co-culture platform for localized CNS axon–glia interaction study
Park, J., Koito, H., Li, J., & Han, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40303j · Cited by 89
Lagus, T. P., & Jon, F. (2013) · RSC Advances · doi:10.1039/c3ra43624a · Cited by 86
Fu, C.-Y., Tseng, S.-Y., Yang, S.-M., Hsu, L., Liu, C.-H., & Chang, H.-Y. (2014) · Biofabrication · doi:10.1088/1758-5082/6/1/015009 · Cited by 86
Park, J. Y., Yoo, S. J., Hwang, C. M., & Lee, S. (2009) · Lab on a Chip · doi:10.1039/b822006a · Cited by 85
Physicochemical regulation of endothelial sprouting in a 3D microfluidic angiogenesis model
Verbridge, S. S., Chakrabarti, A., DelNero, P., Kwee, B., Varner, J. D., Stroock, A. D., & Fischbach, C. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34587 · Cited by 82
Imura, Y., Yoshimura, E., & Sato, K. (2012) · Analytical Sciences · doi:10.2116/analsci.28.197 · Cited by 70
Soe, A. K., Nahavandi, S., & Khoshmanesh, K. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.02.012 · Cited by 70
Recent advances and future applications of microfluidic live-cell microarrays
Rothbauer, M., Wartmann, D., Charwat, V., & Ertl, P. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.06.006 · Cited by 68
Self-citationA bladder cancer microenvironment simulation system based on a microfluidic co-culture model
Liu, P.-F., Cao, Y.-W., Zhang, S.-D., Zhao, Y., Liu, X.-G., Shi, H.-Q., Hu, K.-Y., Zhu, G.-Q., Ma, B., & Niu, H.-T. (2015) · Oncotarget · doi:10.18632/oncotarget.6070 · Cited by 68
Zheng, C., Zhao, L., Chen, G., Zhou, Y., Pang, Y., & Huang, Y. (2012) · Analytical Chemistry · doi:10.1021/ac2032029 · Cited by 67
Electrical Impedance Spectroscopy for Microtissue Spheroid Analysis in Hanging-Drop Networks
Schmid, Y. R. F., Bürgel, S. C., Misun, P. M., Hierlemann, A. R., & Frey, O. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00272 · Cited by 67
Ma, H., Liu, T., Qin, J., & Lin, B. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900776 · Cited by 66
Microfluidic models for adoptive cell-mediated cancer immunotherapies
Adriani, G., Pavesi, A., Tan, A. T., Bertoletti, A., Thiery, J. P., & Kamm, R. D. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.05.006 · Cited by 66
An integrated in vitro model of perfused tumor and cardiac tissue
Moya, M., Tran, D., & George, S. C. (2013) · Stem Cell Research & Therapy · doi:10.1186/scrt376 · Cited by 65
Bridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Microfluidics co-culture systems for studying tooth innervation
Pagella, P., Neto, E., Jiménez‐Rojo, L., Lamghari, M., & Mitsiadis, T. A. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00326 · Cited by 61
Talavera‐Adame, D., Wu, G. D., He, Y., Ng, T. T., Gupta, A., Kurtovic, S., Hwang, J. Y., Farkas, D. L., & Dafoe, D. C. (2011) · Stem Cell Reviews and Reports · doi:10.1007/s12015-011-9232-z · Cited by 60
Adding the ‘heart’ to hanging drop networks for microphysiological multi-tissue experiments
Rismani Yazdi, S., Shadmani, A., Bürgel, S. C., Misun, P. M., Hierlemann, A., & Frey, O. (2015) · Lab on a Chip · doi:10.1039/c5lc01000d · Cited by 60
Mattei, F., Schiavoni, G., De Ninno, A., Lucarini, V., Sestili, P., Sistigu, A., Fragale, A., Sanchez, M., Spada, M., Gerardino, A., et al. (2014) · Journal of Immunotoxicology · doi:10.3109/1547691x.2014.891677 · Cited by 57
A multicellular spheroid formation and extraction chip using removable cell trapping barriers
Jin, H.-J., Cho, Y.-H., Gu, J.-M., Kim, J., & Oh, Y.-S. (2011) · Lab Chip · doi:10.1039/c0lc00134a · Cited by 56
Integrated microfluidic system for cell co-culture and simulation of drug metabolism
Jie, M., Li, H.-F., Lin, L., Zhang, J., & Lin, J.-M. (2016) · RSC Advances · doi:10.1039/c6ra10407j · Cited by 54
Rapid fabrication of nickel molds for prototyping embossed plastic microfluidic devices
Novak, R., Ranu, N., & Mathies, R. A. (2013) · Lab on a Chip · doi:10.1039/c3lc41362d · Cited by 53
A microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4903762 · Cited by 53
Integrated Microfluidics Platforms for Investigating Injury and Regeneration of CNS Axons
Kim, H. J., Park, J. W., Park, J. W., Byun, J. H., Vahidi, B., Rhee, S. W., & Jeon, N. L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0515-6 · Cited by 51
Han, X., Liu, Z., Ma, Y., Zhang, K., & Qin, L. (2017) · Advanced Biosystems · doi:10.1002/adbi.201600007 · Cited by 49
Chang, S.-Y., Voellinger, J. L., Van Ness, K. P., Chapron, B., Shaffer, R. M., Neumann, T., White, C. C., Kavanagh, T. J., Kelly, E. J., & Eaton, D. L. (2017) · Toxicology in Vitro · doi:10.1016/j.tiv.2017.01.007 · Cited by 49
3D microchannel co-culture: method and biological validation
Bauer, M., Su, G., Beebe, D. J., & Friedl, A. (2010) · Integrative Biology · doi:10.1039/c0ib00001a · Cited by 47
Moster, S. J., Moster, M. L., Scannell Bryan, M., & Sergott, R. C. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-17328 · Cited by 47
Analysis of pairwise cell interactions using an integrated dielectrophoretic‐microfluidic system
Yin, Z., Noren, D. P., Wang, C. J., Hang, R., & Levchenko, A. (2008) · Molecular Systems Biology · doi:10.1038/msb.2008.69 · Cited by 46
Microfluidics for cell-cell interactions: A review
Li, R., Lv, X., Zhang, X., Saeed, O., & Deng, Y. (2015) · Frontiers of Chemical Science and Engineering · doi:10.1007/s11705-015-1550-2 · Cited by 44
Monitoring Dynamic Interactions of Tumor Cells with Tissue and Immune Cells in a Lab-on-a-Chip
Charwat, V., Rothbauer, M., Tedde, S. F., Hayden, O., Bosch, J. J., Müellner, P., Hainberger, R., & Ertl, P. (2013) · Analytical Chemistry · doi:10.1021/ac4033406 · Cited by 42
Self-citationIn vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Tong, D. H., Gielens, F. C., Hoang Thi Hanh, H. T. H., Berenschot, E., de Boer, M. J., Gardeniers, J. G. E., Jansen, H. V., Nijdam, W., van Rijn, C. J. M., & Elwenspoek, M. C. (2003) · doi:10.1109/sensor.2003.1216921 · Cited by 38
Exploitation of S-Layer Anisotropy: pH-Dependent Nanolayer Orientation for Cellular Micropatterning
Rothbauer, M., Küpcü, S., Sticker, D., Sleytr, U. B., & Ertl, P. (2013) · ACS Nano · doi:10.1021/nn403198a · Cited by 35
Self-citationWartmann, D., Rothbauer, M., Kuten, O., Barresi, C., Visús, C., Felzmann, T., & Ertl, P. (2015) · Frontiers in Materials · doi:10.3389/fmats.2015.00060 · Cited by 34
Self-citationDevelopment of a three-dimensional microfluidic system for long-term tumor spheroid culture
Kwapiszewska, K., Kwapiszewski, R., Stelmachowska, A., Chudy, M., Dybko, A., & Brzózka, Z. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.07.045 · Cited by 34
Huang, Y., Agrawal, B. M., Clark, P. A., Williams, J. C., & Kuo, J. S. (2011) · Journal of Visualized Experiments · doi:10.3791/3297 · Cited by 31
Charwat, V., Purtscher, M., Tedde, S. F., Hayden, O., & Ertl, P. (2012) · Lab on a Chip · doi:10.1039/c2lc40965h · Cited by 31
Self-citationZheng, J., Liu, Q., Yang, J., Ren, Q., Cao, W. W., Yang, J., Yu, Z., Yu, F., Wu, Y., Shi, H.-J., et al. (2012) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2012007500061 · Cited by 30
Shojaei, S., Tafazzoli‐Shadpour, M., Shokrgozar, M. A., & Haghighipour, N. (2013) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000242 · Cited by 29
Patterning bio-molecules for cell attachment at single cell levels in PDMS microfluidic chips
Wang, L., Lei, L., Ni, X. F., Shi, J., & Chen, Y. (2009) · Microelectronic Engineering · doi:10.1016/j.mee.2009.01.030 · Cited by 28
Nano-volume drop patterning for rapid on-chip neuronal connect-ability assays
Petrelli, A., Marconi, E., Salerno, M., Tonelli, D. D. P., Berdondini, L., & Dante, S. (2013) · Lab on a Chip · doi:10.1039/c3lc50564b · Cited by 24
Herricks, T., Seydel, K. B., Turner, G., Molyneux, M. E., Heyderman, R. S., Taylor, T. E., & Rathod, P. K. (2011) · Lab on a Chip · doi:10.1039/c1lc20131j · Cited by 24
A microfluidic approach towards hybridoma generation for cancer immunotherapy
Lu, Y., Pendharkar, G. P., Lu, C.-H., Chang, C., & Liu, C. (2015) · Oncotarget · doi:10.18632/oncotarget.5550 · Cited by 24
Kaji, H., Yokoi, T., Kawashima, T., & Nishizawa, M. (2010) · Lab on a Chip · doi:10.1039/c004583g · Cited by 22
Reichen, M., Veraitch, F. S., & Szita, N. (2013) · SLAS TECHNOLOGY · doi:10.1177/2211068213499917 · Cited by 22
Shin, H. S., Kim, H. J., Min, S. K., Kim, S. H., Lee, B. M., & Jeon, N. L. (2010) · Biotechnology Letters · doi:10.1007/s10529-010-0280-2 · Cited by 22
Mechanical stimulation of bovine embryos in a microfluidic culture platform
Bae, C. Y., Kim, M. S., & Park, J. (2011) · BioChip Journal · doi:10.1007/s13206-011-5202-4 · Cited by 19
Rothbauer, M., Ertl, P., Theiler, B. A., Schlager, M., Sleytr, U. B., & Küpcü, S. (2014) · Advanced Materials Interfaces · doi:10.1002/admi.201400309 · Cited by 19
Self-citationHuman blinking ‘eye-on-a-chip’
Seo, J., Byun, W. Y., Frank, A. J., Massaro‐Giordano, M., Lee, V., Bunya, V. Y., & Huh, D. (2016) · Investigative Ophthalmology & Visual Science · Cited by 19
Chen, Y., Ingram, P., & Yoon, E. (2014) · The Analyst · doi:10.1039/c4an01282h · Cited by 18
Integration of microstructured scaffolds, neurons, and multielectrode arrays
Simi, A., Amin, H., Maccione, A., Nieus, T. R., & Berdondini, L. (2014) · Progress in brain research · doi:10.1016/b978-0-444-63486-3.00017-7 · Cited by 10
Higashimori, H., & Yang, Y. (2012) · Journal of Visualized Experiments · doi:10.3791/4448 · Cited by 8
Frey, O., Misun, P. M., Rothe, J., & Hierlemann, A. R. (2014) · Procedia Engineering · doi:10.1016/j.proeng.2014.11.274 · Cited by 7
Purtscher, M., Rothbauer, M., Holnthoner, W., Redl, H. R., & Ertl, P. (2014) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-11128-5_78 · Cited by 4
Self-citationCapillary-valve-based platform towards cell-on-chip mechanotransduction assays
Hausherr, T. C., Majd, H., Joss, D., Müller, A., Pioletti, D. P., Gijs, M. A. M., & Yamahata, C. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.07.050 · Cited by 4
Misun, P. M., Rothe, J., Hierlemann, A. R., & Frey, O. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7181252 · Cited by 3
Bürgel, S. C., Schmid, Y. R. F., Agarkova, I., Fluri, D. A., Kelm, J. M., Hierlemann, A. R., & Frey, O. (2015) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2015.7050928 · Cited by 3
Crystalline Bacterial Protein Nanolayers for Cell Micropatterning
Rothbauer, M., Küpcü, S., Sleytr, U. B., & Ertl, P. (2014) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-11128-5_84 · Cited by 3
Self-citationMicrofluidic hanging-drop platform for parallel closed-loop multi-tissue experiments
Yazdi, S. R., Shadmani, A., Hierlemann, A. R., & Frey, O. (2015) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2015.7051010 · Cited by 2
Research works printed but not linked: 11
- C. D. Rudd , C. M.Duffy , M. S.Johnson and P. J.Blanchard , Broader Meaning to Thermosets , 1998 , pp. 177–177
- M. Rothbauer , S.Kupcu , U. B.Sleytr and P.Ertl , Ifmbe Proc , 2015 , vol. 45 , pp. 337–340
- Millet, 2012, Yale J. Biol. Med., 85, 501
- M. Purtscher , M.Rothbauer , W.Holnthoner , H.Redl and P.Ertl , Ifmbe Proc , 2015 , vol. 45 , pp. 313–317
- Vu, 2017, Lab Chip, 17, 1009, 10.1039/C6LC01367H · DOI · Paper page
- Hofer, 1991, Cancer Res., 51, 2780
- P. M. Misun , J.Rothe , A.Hierlemann and O.Frey , 2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems , 2015 , pp. 1625–1628
- S. R. Yazdi , A.Shadmani , A.Hierlemann and O.Frey , 2015 28th Ieee International Conference on Micro Electro Mechanical Systems (Mems 2015) , 2015 , pp. 535–538
- S. Miura , Y.Morimoto and S.Takeuchi , Proc Ieee Micr Elect , 2013 , pp. 257–258
- Miura, 2015, Nat. Commun., 6
- Maoz, 2017, Lab Chip, 17, 2294, 10.1039/C7LC00412E · DOI · Paper page
Cited by
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
“To accomplish this, OOCs take advantage of control strategies andmultiparametric approaches designed for microfluidic systems (Park and Shuler, 2003; Rothbauer et al., 2018; Smith et al., 2013; Xu et al., 2016).”
Background3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions
Rodrigues, J., Heinrich, M. A., Teixeira, L. M., & Prakash, J. (2021) · Trends in Cancer · doi:10.1016/j.trecan.2020.10.009 · Cited by 405
Towards a deeper understanding of the vaginal microbiota
France, M., Alizadeh, M., Brown, S., Ma, B., & Ravel, J. (2022) · Nature Microbiology · doi:10.1038/s41564-022-01083-2 · Cited by 382
Tumor microenvironment: barrier or opportunity towards effective cancer therapy
Tiwari, A., Trivedi, R., & Lin, S.-Y. (2022) · Journal of Biomedical Science · doi:10.1186/s12929-022-00866-3 · Cited by 377
“These models can be used to study tumor-stroma interactions and their systemic effects simultaneously [27, 242, 243].”
BackgroundTumor microenvironment signaling and therapeutics in cancer progression
Goenka, A., Khan, F., Verma, B., Sinha, P., Dmello, C. C., Jogalekar, M. P., Gangadaran, P., & Ahn, B. (2023) · Cancer Communications · doi:10.1002/cac2.12416 · Cited by 323
Metadata
- Authors
- Rothbauer, M., Zirath, H., & Ertl, P.
- Affiliations
- TU Wien (AT)
- Corresponding author
- Ertl, Peter
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 18
- Issue
- 2
- Pages
- 249-270
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2765218320
- Cited by
- 277
- References
- 163
- Citations by year
- 2026: 11 · 2025: 22 · 2024: 28 · 2023: 27 · 2022: 37 · 2021: 35 · 2020: 47 · 2019: 44 · 2018: 25
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Lab on a Chip (publishedVersion, cc-by)
- PubMed (publishedVersion)
- reposiTUm (TU Wien) (submittedVersion, cc-by)
- reposiTUm (TU Wien) (submittedVersion)
- Funders
- Österreichische Forschungsförderungsgesellschaft (849791)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- microfluidic cell culture, cell-cell interactions, organ-on-a-chip, multi-organ-on-a-chip, 3D cell culture, single-cell analysis, cancer research, immunotherapy, vascular model, signal transduction, drug screening, toxicological testing, tissue engineering
- MeSH terms
- Cell Communication, Equipment Design, Humans, Models, Biological, Cell Culture Techniques, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.