Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Open accessThe DOI matches its Crossref record; 187 of the 193 references it cites were found in a registry or an index.
Abstract
Coronavirus disease 2019 (COVID-19) has emerged as a pandemic with serious clinical manifestations including death. A pandemic at the large-scale like COVID-19 places extraordinary demands on the world's health systems, dramatically devastates vulnerable populations, and critically threatens the global communities in an unprecedented way. While tremendous efforts at the frontline are placed on detecting the virus, providing treatments and developing vaccines, it is also critically important to examine the technologies and systems for tackling disease emergence, arresting its spread and especially the strategy for diseases prevention. The objective of this article is to review enabling technologies and systems with various application scenarios for handling the COVID-19 crisis. The article will focus specifically on 1) wearable devices suitable for monitoring the populations at risk and those in quarantine, both for evaluating the health status of caregivers and management personnel, and for facilitating triage processes for admission to hospitals; 2) unobtrusive sensing systems for detecting the disease and for monitoring patients with relatively mild symptoms whose clinical situation could suddenly worsen in improvised hospitals; and 3) telehealth technologies for the remote monitoring and diagnosis of COVID-19 and related diseases. Finally, further challenges and opportunities for future directions of development are highlighted.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China
Huang, C., Wang, Y., Li, X., Ren, L., Zhao, J., Hu, Y., Zhang, L., Fan, G., Xu, J., Gu, X., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30183-5 · Cited by 48,884
Zhou, F., Yu, T., Du, R., Fan, G., Liu, Y., Liu, Z., Xiang, J., Wang, Y., Song, B., Gu, X., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30566-3 · Cited by 27,263 · cited 2×
“A retrospective cohort study of adult inpatients with COVID-19 in Wuhan showed that 63% (34 out of 54) of the patients who died from the disease had a RR higher than 24 breaths per min, compared with that of 16% (22 out of 137) of survivors [39].”
BackgroundResultSelf-citationHoffmann, M., Kleine-Weber, H., Schroeder, S., Krüger, N., Herrler, T., Erichsen, S., Schiergens, T. S., Herrler, G., Wu, N.-H., Nitsche, A., et al. (2020) · Cell · doi:10.1016/j.cell.2020.02.052 · Cited by 20,286 · cited 1×
“The lungs may be inflamed, causing dyspnea and leading to rapidly progressive ARDS; furthermore it can lead to pneumonia, an infection of the alveoli inside the lungs where the blood exchanges oxygen and carbon dioxide [19].”
BackgroundWang, D., Hu, B., Hu, C., Zhu, F., Liu, X., Zhang, J., Wang, B., Xiang, H., Cheng, Z., Xiong, Y., et al. (2020) · JAMA · doi:10.1001/jama.2020.1585 · Cited by 20,148 · cited 1×
“COVID-19, 58% were hypertensive, 25% with heart disease and 44% with arrhythmia [70].”
BackgroundLa certeza de lo impredecible: Cultura Educación y Sociedad en tiempos de COVID19
Martínez González, M. (2020) · DSPACE System - Metalibrary (University of the Coast) · Cited by 18,463
Wu, Z., & McGoogan, J. M. (2020) · JAMA · doi:10.1001/jama.2020.2648 · Cited by 17,016 · cited 1×
“of cases presenting with severe symptoms and 5% requiring intensive care, including invasive mechanical ventilation [10].”
BackgroundRichardson, S., Hirsch, J. S., Narasimhan, M., Crawford, J. M., McGinn, T., Davidson, K. W., and the Northwell COVID-19 Research Consortium, Barnaby, D. P., Becker, L. B., Chelico, J. D., et al. (2020) · JAMA · doi:10.1001/jama.2020.6775 · Cited by 9,254
Lai, C.-C., Shih, T.-P., Ko, W.-C., Tang, H.-J., & Hsueh, P.-R. (2020) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2020.105924 · Cited by 6,068 · cited 1×
“Among adult patients, CVD and hypertension were the most common comorbidities [69].”
Ruan, Q., Yang, K., Wang, W., Jiang, L., & Song, J. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-05991-x · Cited by 4,898 · cited 10×
“The mechanisms of cardiovascular damage caused by SARS-CoV-2 are not clear yet, but may involve increased cardiac stress due to respiratory failure and hypoxemia, direct myocardial infection resulting from the virus attack of the lining of the heart and blood vessels that are rich in ACE2 receptors [65], indirect inju…”
BackgroundInfluentialAssociation of cardiac injury with mortality in hospitalized patients with COVID-19 in Wuhan, China
Shi, S., Qin, M., Shen, B., Cai, Y., Liu, T., Yang, F., Gong, W., Liu, X., Liang, J., Zhao, Q., et al. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2020.0950 · Cited by 4,349 · cited 1×
“with COVID-19 had cardiac injury during hospitalization [63]; another study found that 27.”
Cardiovascular implications of fatal outcomes of patients with Coronavirus Disease 2019 (COVID-19)
Guo, T., Fan, Y., Chen, M., Wu, X., Zhang, L., He, T., Wang, H., Wan, J., Wang, X., & Lu, Z. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2020.1017 · Cited by 4,194 · cited 1×
“8% of patient has myocardial injury, which resulted in cardiac dysfunction and arrhythmias [64].”
BackgroundCase-fatality rate and characteristics of patients dying in relation to COVID-19 in Italy
Onder, G., Rezza, G., & Brusaferro, S. (2020) · JAMA · doi:10.1001/jama.2020.4683 · Cited by 4,171 · cited 1×
“the most-affected countries [1-3], and it is an acute public health”
BackgroundCOVID-19 and the cardiovascular system
Zheng, Y.-Y., Ma, Y.-T., Zhang, J.-Y., & Xie, X. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0360-5 · Cited by 2,970 · cited 10×
“The mechanisms of cardiovascular damage caused by SARS-CoV-2 are not clear yet, but may involve increased cardiac stress due to respiratory failure and hypoxemia, direct myocardial infection resulting from the virus attack of the lining of the heart and blood vessels that are rich in ACE2 receptors [65], indirect inju…”
BackgroundInfluentialTime Course of Lung Changes at Chest CT during Recovery from Coronavirus Disease 2019 (COVID-19)
Pan, F., Ye, T., Sun, P., Gui, S., Liang, B., Li, L., Zheng, D., Wang, J., Hesketh, R. L., Yang, L., et al. (2020) · Radiology · doi:10.1148/radiol.2020200370 · Cited by 2,856 · cited 1×
“, a patient with severe respiratory distress has an RR greater than 30 breaths/min that can develop into ARDS [9], [38].”
BackgroundProjecting the transmission dynamics of SARS-CoV-2 through the postpandemic period
Kissler, S. M., Tedijanto, C., Goldstein, E., Grad, Y. H., & Lipsitch, M. (2020) · Science · doi:10.1126/science.abb5793 · Cited by 2,611 · cited 6×
“Lessons from epidemic centers such as China, Italy and United States show that COVID-19 can suppress the capacity of health care systems even in countries with extensive health resources and universal care [12].”
BackgroundInfluentialFeasibility of controlling COVID-19 outbreaks by isolation of cases and contacts
Hellewell, J., Abbott, S., Gimma, A., Bosse, N. I., Jarvis, C. I., Russell, T. W., Munday, J. D., Kucharski, A. J., Edmunds, W. J., Sun, F., et al. (2020) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30074-7 · Cited by 2,550 · cited 1×
“and case isolation are known to be one of the key strategies to control the COVID-19 outbreak [167].”
BackgroundQuantifying SARS-CoV-2 transmission suggests epidemic control with digital contact tracing
Ferretti, L., Wymant, C., Kendall, M., Zhao, L., Nurtay, A., Abeler-Dörner, L., Parker, M., Bonsall, D., & Fraser, C. (2020) · Science · doi:10.1126/science.abb6936 · Cited by 2,512 · cited 2×
“A contact-tracing app that builds a library of close contacts and immediately alerts contacts of positive cases can achieve epidemic control if used by enough people [169].”
BackgroundPresymptomatic SARS-CoV-2 Infections and Transmission in a Skilled Nursing Facility
Arons, M. M., Hatfield, K. M., Reddy, S. C., Kimball, A., James, A., Jacobs, J. R., Taylor, J., Spicer, K., Bardossy, A. C., Oakley, L. P., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2008457 · Cited by 2,052 · cited 1×
“asymptomatic rate was as high as 56% (27 out of 57), about 90% of which subsequently developed symptoms [16].”
BackgroundDriggin, E., Madhavan, M. V., Bikdeli, B., Chuich, T., Laracy, J., Biondi-Zoccai, G., Brown, T. S., Der Nigoghossian, C., Zidar, D. A., Haythe, J., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.03.031 · Cited by 2,017
Telehealth for global emergencies: Implications for coronavirus disease 2019 (COVID-19)
Smith, A. C., Thomas, E., Snoswell, C. L., Haydon, H., Mehrotra, A., Clemensen, J., & Caffery, L. J. (2020) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x20916567 · Cited by 1,828 · cited 1×
“Telehealth technology including mHealth and telemedicine is not new but has emerged as a critical tool in the fight against COVID-19 [161].”
MethodPotential Effects of Coronaviruses on the Cardiovascular System: A Review
Madjid, M., Safavi-Naeini, P., Solomon, S. D., & Vardeny, O. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2020.1286 · Cited by 1,793 · cited 1×
“patients even without underlying heart conditions [15].”
Viral dynamics in mild and severe cases of COVID-19
Liu, Y., Yan, L.-M., Wan, L., Xiang, T.-X., Le, A., Liu, J.-M., Peiris, M., Poon, L. L. M., & Zhang, W. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30232-2 · Cited by 1,727 · cited 2×
“to an ICU [17], and patients with an SpO2 lower than 90% during admission are more likely to die [22].”
BackgroundSelf-citationCOVID-19: immunopathology and its implications for therapy
Cao, X. (2020) · Nature Reviews Immunology · doi:10.1038/s41577-020-0308-3 · Cited by 1,609 · cited 1×
“These studies indicate that the vulnerable population such as those with an underlying conditions suffer a higher risk of severe complications from COVID-19 [39], [93].”
BackgroundCOVID-19 infection: the perspectives on immune responses
Shi, Y., Wang, Y., Shao, C., Huang, J., Gan, J., Huang, X., Bucci, E., Piacentini, M., Ippolito, G., & Melino, G. (2020) · Cell Death & Differentiation · doi:10.1038/s41418-020-0530-3 · Cited by 1,594 · cited 1×
“leading to hypoxia and impending organ damage [20].”
BackgroundDigital technology and COVID-19
Ting, D. S. W., Carin, L., Dzau, V., & Wong, T. Y. (2020) · Nature Medicine · doi:10.1038/s41591-020-0824-5 · Cited by 1,413 · cited 1×
“Internet of Things, big-data analytics, AI and blockchain [163], can alleviate the challenge with a paradigm shift in health care.”
BackgroundReview of the Clinical Characteristics of Coronavirus Disease 2019 (COVID-19)
Jiang, F., Deng, L., Zhang, L., Cai, Y., Cheung, C. W., & Xia, Z. (2020) · Journal of General Internal Medicine · doi:10.1007/s11606-020-05762-w · Cited by 1,410 · cited 1×
“COVID-19 are fever (90% of cases or above), cough (around 75%) and dyspnea (up to 50%) [139].”
BackgroundShi, F., Wang, J., Shi, J., Wu, Z., Wang, Q., Tang, Z., He, K., Shi, Y., & Shen, D. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2987975 · Cited by 1,404 · cited 2×
“Of note, the AI-assisted image processing methods for diagnosis of COVID-19 are comprehensively discussed in another review [182].”
MethodSelf-citationCovid-19 and Health Care’s Digital Revolution
Keesara, S., Jonas, A., & Schulman, K. (2020) · New England Journal of Medicine · doi:10.1056/nejmp2005835 · Cited by 1,126 · cited 2×
“of electronic or digital health technologies [162].”
BackgroundUltraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024 · cited 2×
“Left column: flexible organic reflectance oximeter array [35]; middle column: ultra-flexible organic photonic skin [36]; right column: miniaturized battery-free wireless systems for wearable pulse oximetry [33].”
MethodMonitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895 · cited 2×
“normalized pulse volume [112], acceleration plethysmography (APG) [113], and diameter of a pulsating blood vessel [114].”
BackgroundThe emerging field of mobile health
Steinhubl, S. R., Muse, E. D., & Topol, E. J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3487 · Cited by 822 · cited 1×
“Portable medical imaging devices (a) portable ultrasound system (Butterfly) [113], [176], (b) Optima XR220amx portal X ray (GE) [177], (c) BodyTom CT scanner (Samsung) [115], [178], and (d) portable MRI (Hyperfine) [166], [179].”
BackgroundBinodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807 · cited 1×
“Flexible ECG technologies: (a) an e-tattoo ECG [86], (b) a multiparametric epidermal sensor [87], (c) a graphene e-tattoo ECG [88], and (d) an epidermal sensing system with in-sensor analytics [89].”
MethodSelf-citationIstepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766 · cited 1×
“a tablet computers, and other wireless devices [165].”
BackgroundSelf-citationUnobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722 · cited 3×
“application [95], thus will not be listed here.”
BackgroundInfluentialSelf-citationAkhmerov, A., & Marbán, E. (2020) · Circulation Research · doi:10.1161/circresaha.120.317055 · Cited by 693
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669 · cited 1×
“Flexible ECG technologies: (a) an e-tattoo ECG [86], (b) a multiparametric epidermal sensor [87], (c) a graphene e-tattoo ECG [88], and (d) an epidermal sensing system with in-sensor analytics [89].”
MethodChu, H., Chan, J. F.-W., Wang, Y., Yuen, T. T.-T., Chai, Y., Hou, Y., Shuai, H., Yang, D., Hu, B., Huang, X., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa410 · Cited by 667 · cited 1×
“Though SARS-CoV-2 and SARS-CoV share some common clinical manifestations, a new study shows that SARS-CoV-2 is highly efficient in person-to-person transmission and frequently causes asymptomatic infections [4].”
Cardiac and arrhythmic complications in patients with COVID‐19
Kochi, A. N., Tagliari, A. P., Forleo, G. B., Fassini, G. M., & Tondo, C. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14479 · Cited by 666
AI4COVID-19: AI enabled preliminary diagnosis for COVID-19 from cough samples via an app
Imran, A., Posokhova, I., Qureshi, H. N., Masood, U., Riaz, M. S., Ali, K., John, C. N., Hussain, M. I., & Nabeel, M. (2020) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2020.100378 · Cited by 621 · cited 1×
“It demonstrated an ability to distinguish the COVID-19 cough from non-COVID-19-related cough with over 90% accuracy [149].”
BackgroundCombating COVID-19—The role of robotics in managing public health and infectious diseases
Yang, G.-Z., J. Nelson, B., Murphy, R. R., Choset, H., Christensen, H., H. Collins, S., Dario, P., Goldberg, K., Ikuta, K., Jacobstein, N., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.abb5589 · Cited by 563 · cited 1×
“Telerobotics can be potentially deployed for combating COVID-19 in four aspects [217]: i) disease prevention, e.”
BackgroundPhotoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556 · cited 1×
“The iPPG can indicate the local changes of dermal blood volume, and can be used to estimate physiological parameters including HR, SpO2, RR and BP [138], [153].”
MethodSteinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539 · cited 2×
“times higher compared with regular ECG check [80].”
BackgroundOn the responsible use of digital data to tackle the COVID-19 pandemic
Ienca, M., & Vayena, E. (2020) · Nature Medicine · doi:10.1038/s41591-020-0832-5 · Cited by 491 · cited 2×
“The large-scale collection of mobile data from millions of users raises concerns over privacy and confidentiality [168].”
BackgroundLilly, C. M. (2011) · JAMA · doi:10.1001/jama.2011.697 · Cited by 487 · cited 1×
“alarms and off-site care plan review compared with a traditional ICU [185], [186].”
Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement
Luo, N., Dai, W., Li, C., Zhou, Z., Lu, L., Poon, C. C. Y., Chen, S., Zhang, Y., & Zhao, N. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504560 · Cited by 467 · cited 3×
“Wearable/unobtrusive BP monitoring platforms with realization in daily objects: (a) BP watch [121], (b) BP eyeglasses [123], (c) flexible BP patch [129], (d) BP shirt [126], (e) wearable skin-like BP patch [131], (f) near-infrared phototransistor for BP [227], (g) BP chair [128], (h) BP camera [138], and (i) BP sleepi…”
BackgroundSelf-citationRespiration rate and volume measurements using wearable strain sensors
Chu, M., Nguyen, T., Pandey, V., Zhou, Y., Pham, H. N., Bar-Yoseph, R., Radom-Aizik, S., Jain, R., Cooper, D. M., & Khine, M. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0083-3 · Cited by 403 · cited 2×
“Wearable RR monitor products: (a) Spire medical health tag (Spire Health, USA) [47], RespiraSenseTM patch (PMD Solutions, Ireland) [48], and MonBaby clip (MonBaby, New York, USA) [49], (b) ZephyrTM garment (Zephyr Technology, Auckland, New Zealand) [50], and state-of-the-art research, (c) an epidermal thermal sensor […”
BackgroundGiudicessi, J. R., Noseworthy, P. A., Friedman, P. A., & Ackerman, M. J. (2020) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2020.03.024 · Cited by 394 · cited 2×
“com/story/apple-googlebluetooth-contact-tracing-covid-19/ [172] J.”
MethodCOVID-19 in Italy: momentous decisions and many uncertainties
Lazzerini, M., & Putoto, G. (2020) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30110-8 · Cited by 380 · cited 4×
“In the following, we suggest some promising directions on the development and deployment of wearable devices, unobtrusive sensing and telehealth for future research and application: i) To develop more sophisticated multi-parameter flexible and stretchable sensing based wearable devices and mHealth platforms with robus…”
BackgroundInfluentialBreathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379 · cited 14×
“The iPPG can indicate the local changes of dermal blood volume, and can be used to estimate physiological parameters including HR, SpO2, RR and BP [138], [153].”
BackgroundInfluentialSelf-citationCuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time
Poon, C. C. Y., & Zhang, Y. T. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1615827 · Cited by 375 · cited 1×
“ECG as the proximal and PPG as the distal timing reference [96]–[98].”
Self-citationMacLaren, G., Fisher, D., & Brodie, D. (2020) · JAMA · doi:10.1001/jama.2020.2342 · Cited by 370 · cited 1×
“It can also save many lives by making oximetry widely available, in particular in less well-resourced countries [24], [25].”
BackgroundAuscultation of the respiratory system
Sarkar, M., Madabhavi, I., Niranjan, N., & Dogra, M. (2015) · Annals of Thoracic Medicine · doi:10.4103/1817-1737.160831 · Cited by 362 · cited 1×
“It is noninvasive, safe, easy to perform, low cost and commonly used by a physician to diagnose various cardiopulmonary diseases [56].”
BackgroundBattery-free, wireless sensors for full-body pressure and temperature mapping
Han, S., Kim, J., Won, S. M., Ma, Y., Kang, D., Xie, Z., Lee, K.-T., Chung, H. U., Banks, A., Min, S., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aan4950 · Cited by 351 · cited 2×
“Wearable temperature monitoring: (a) TempTraq® temperature Bluetooth-enabled patch [145], (b) foam-based flexible thermal sensor [144], (c) epidermal wireless thermal sensor array [142], and (d) headband thermometry [143].”
BackgroundMethodMiniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry
Kim, J., Gutruf, P., Chiarelli, A. M., Heo, S. Y., Cho, K., Xie, Z., Banks, A., Han, S., Jang, K., Lee, J. W., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201604373 · Cited by 334 · cited 2×
“reported flexible wearable battery-free pulse oximetry that employed novel material with near-field communication technology for power supply [33].”
BackgroundDing, X.-R., Zhang, Y.-T., Liu, J., Dai, W.-X., & Tsang, H. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2480679 · Cited by 330 · cited 1×
“other physiological features have been investigated to indicate BP changes, including PPG intensity ratio [109], Womersley number [110], radial electrical bioimpedance [111], modified”
BackgroundSelf-citationSheridan, T. B. (1989) · Automatica · doi:10.1016/0005-1098(89)90093-9 · Cited by 308 · cited 1×
“Telerobotics refers to remote control of semi-autonomous robots, which conceptually lies between teleoperations and autonomous robots [216].”
Background“Cut‐and‐Paste” Manufacture of Multiparametric Epidermal Sensor Systems
Yang, S., Chen, Y., Nicolini, L., Pasupathy, P., Sacks, J., Su, B., Yang, R., Sanchez, D., Chang, Y., Wang, P., et al. (2015) · Advanced Materials · doi:10.1002/adma.201502386 · Cited by 304 · cited 1×
“Flexible ECG technologies: (a) an e-tattoo ECG [86], (b) a multiparametric epidermal sensor [87], (c) a graphene e-tattoo ECG [88], and (d) an epidermal sensing system with in-sensor analytics [89].”
MethodLazzeri, M., Lanza, A., Bellini, R., Bellofiore, A., Cecchetto, S., Colombo, A., D'Abrosca, F., Del Monaco, C., Gaudellio, G., Paneroni, M., et al. (2020) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2020.1285 · Cited by 295 · cited 1×
“are recommended to patients with spontaneous breathing, with invasive mechanical ventilation for those in an acute phases [200].”
BackgroundChen, C., Chen, C., Yan, J. T., Zhou, N., Zhao, J. P., & Wang, D. W. (2020) · PubMed · doi:10.3760/cma.j.cn112148-20200225-00123 · Cited by 283 · cited 1×
“significantly affect heart function and lead to myocardial injury and possibly cause chronic damage to the cardiovascular system [62].”
BackgroundA flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278 · cited 2×
“Left column: flexible organic reflectance oximeter array [35]; middle column: ultra-flexible organic photonic skin [36]; right column: miniaturized battery-free wireless systems for wearable pulse oximetry [33].”
BackgroundLee, H., Kim, E., Lee, Y., Kim, H., Lee, J., Kim, M., Yoo, H.-J., & Yoo, S. (2018) · Science Advances · doi:10.1126/sciadv.aas9530 · Cited by 274 · cited 1×
“a reflective patch-type oximeter with a flexible organic LED and organic photodiodes that has ultralow power consumption compared with typical LEDs and detectors [34].”
MethodTan, W., & Aboulhosn, J. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.03.063 · Cited by 268 · cited 1×
“telemedicine solutions made for patients with other cardiovascular conditions including heart failure andcongenital heart disease [222-226].”
BackgroundUltrafast Response Polyelectrolyte Humidity Sensor for Respiration Monitoring
Dai, J., Zhao, H., Lin, X., Liu, S., Liu, Y., Liu, X., Fei, T., & Zhang, T. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b18904 · Cited by 266 · cited 2×
“Wearable RR monitor products: (a) Spire medical health tag (Spire Health, USA) [47], RespiraSenseTM patch (PMD Solutions, Ireland) [48], and MonBaby clip (MonBaby, New York, USA) [49], (b) ZephyrTM garment (Zephyr Technology, Auckland, New Zealand) [50], and state-of-the-art research, (c) an epidermal thermal sensor […”
BackgroundLakkireddy, D. R., Chung, M. K., Gopinathannair, R., Patton, K. K., Gluckman, T. J., Turagam, M., Cheung, J. W., Patel, P., Sotomonte, J., Lampert, R., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.03.028 · Cited by 259
Hong, Y.-R., Lawrence, J., Williams Jr, D., & Mainous III, A. (2020) · JMIR Public Health and Surveillance · doi:10.2196/18961 · Cited by 236 · cited 1×
“tele-ICU infrastructures, as the current capacity of tele-ICU does not meet the established demand of patients in the United States during the pandemic [197].”
BackgroundRecommendations for respiratory rehabilitation in adults with coronavirus disease 2019
Zhao, H.-M., Xie, Y.-X., & Wang, C. (2020) · Chinese Medical Journal · doi:10.1097/cm9.0000000000000848 · Cited by 232
Nanogenerator-Based Self-Powered Sensors for Wearable and Implantable Electronics
Li, Z., Zheng, Q., Wang, Z. L., & Li, Z. (2020) · Research · doi:10.34133/2020/8710686 · Cited by 223 · cited 1×
“Consequently, technologies that harvest energy from the human body or surrounding environment [133] should be further developed and integrated with BP”
BackgroundHa, T., Tran, J., Liu, S., Jang, H., Jeong, H., Mitbander, R., Huh, H., Qiu, Y., Duong, J., Wang, R. L., et al. (2019) · Advanced Science · doi:10.1002/advs.201900290 · Cited by 220 · cited 2×
“A proposed unobtrusive 24 hour multiple physiological parameters remote monitoring system consisting of a BSN connecting with wearable and flexible devices: (a) a HR/BP glasses [123], (b) BP watch [137], (c) SpO2 ring [159], (d) flexible RR/cough patch [45], (e) flexible temperature patch [145], and (f) flexible ECG s…”
MethodA Multicenter Study of ICU Telemedicine Reengineering of Adult Critical Care
Lilly, C. M., McLaughlin, J. M., Zhao, H., Baker, S. P., Cody, S., & Irwin, R. S. (2014) · Chest · doi:10.1378/chest.13-1973 · Cited by 219 · cited 1×
“alarms and off-site care plan review compared with a traditional ICU [185], [186].”
Recent directions in telemedicine: Review of trends in research and practice
Wilson, L. S., & Maeder, A. J. (2015) · Healthcare Informatics Research · doi:10.4258/hir.2015.21.4.213 · Cited by 203 · cited 1×
“Telemedicine is the use of telecommunications to diagnose and treat diseases [175].”
BackgroundLong-term blood pressure prediction with deep recurrent neural networks
Su, P., Ding, X.-R., Zhang, Y.-T., Liu, J., Miao, F., & Zhao, N. (2018) · 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2018.8333434 · Cited by 203 · cited 1×
“estimation to develop regression models between signal features and BP, and demonstrating promising estimation accuracy [115-120].”
Self-citationPeer-to-Peer Contact Tracing: Development of a Privacy-Preserving Smartphone App
Yasaka, T. M., Lehrich, B. M., & Sahyouni, R. (2020) · JMIR mHealth and uHealth · doi:10.2196/18936 · Cited by 202 · cited 1×
“the privacy of the user, and can be potentially applied to the COVID-19 pandemic [170].”
BackgroundNacoti, M., CioccaAndrea, GiupponiAngelo, BrambillascaPietro, LussanaFederico, PisanoMichele, GoisisGiuseppe, BonacinaDaniele, FazziFrancesco, NasproRichard, et al. (2020) · NEJM Catalyst · Cited by 192
Gorodeski, E. Z., Goyal, P., Cox, Z. L., Thibodeau, J. T., Reay, R. E., Rasmusson, K., Rogers, J. G., & Starling, R. C. (2020) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2020.04.008 · Cited by 189 · cited 1×
“telemedicine solutions made for patients with other cardiovascular conditions including heart failure andcongenital heart disease [222-226].”
BackgroundElectrocardiographic patch devices and contemporary wireless cardiac monitoring
Fung, E., Järvelin, M.-R., Doshi, R. N., Shinbane, J. S., Carlson, S. K., Grazette, L. P., Chang, P. M., Sangha, R. S., Huikuri, H. V., & Peters, N. S. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00149 · Cited by 188 · cited 2×
“However, the main disadvantages of the patch ECG monitor includes high cost due to the disposable nature of the device, and dependence on the device company for raw data retrieval which can cause delays between data collection and data processing [81].”
BackgroundDing, X.-R., Zhao, N., Yang, G.-Z., Pettigrew, R. I., Lo, B., Miao, F., Li, Y., Liu, J., & Zhang, Y.-T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2620995 · Cited by 181 · cited 1×
“Relevant research before 2016 may refer to earlier work [94, 95].”
Self-citationHuynh, T. H., Jafari, R., & Chung, W.-Y. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2865751 · Cited by 178 · cited 1×
“Several studies use alternative cardiac signals for ECG, such as impedance plethysmography (IPG) [99], [100], phonocardiogram (PCG) [101], [102], or ballistocardiogram”
BackgroundWang, Y., Hu, M., Li, Q., Zhang, X.-P. S., Zhai, G., & Yao, N. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2002.05534 · Cited by 178
An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
Zheng, Y.-L., Yan, B. P., Zhang, Y.-T., & Poon, C. C. Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2318779 · Cited by 177 · cited 1×
“The typical PTT-based BP estimation model utilizes ECG as the proximal and PPG as the distal timing reference [96-98].”
MethodSelf-citationA Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques
Miao, F., Fu, N., Zhang, Y.-T., Ding, X.-R., Hong, X., He, Q., & Li, Y. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2691715 · Cited by 174 · cited 1×
“estimation to develop regression models between signal features and BP, and demonstrating promising estimation accuracy [115-120].”
Self-citationNon-Invasive Blood Pressure Estimation from ECG Using Machine Learning Techniques
Simjanoska, M., Gjoreski, M., Gams, M., & Madevska Bogdanova, A. (2018) · Sensors · doi:10.3390/s18041160 · Cited by 164 · cited 1×
“estimation to develop regression models between signal features and BP, and demonstrating promising estimation accuracy [115-120].”
A high-sensitivity near-infrared phototransistor based on an organic bulk heterojunction
Xu, H., Li, J., Leung, B. H. K., Poon, C. C. Y., Ong, B. S., Zhang, Y., & Zhao, N. (2013) · Nanoscale · doi:10.1039/c3nr03989g · Cited by 163 · cited 1×
“Wearable/unobtrusive BP monitoring platforms with realization in daily objects: (a) BP watch [121], (b) BP eyeglasses [123], (c) flexible BP patch [129], (d) BP shirt [126], (e) wearable skin-like BP patch [131], (f) near-infrared phototransistor for BP [227], (g) BP chair [128], (h) BP camera [138], and (i) BP sleepi…”
BackgroundSelf-citationWaist-wearable wireless respiration sensor based on triboelectric effect
Zhang, H., Zhang, J., Hu, Z., Quan, L., Shi, L., Chen, J., Xuan, W., Zhang, Z., Dong, S., & Luo, J. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.063 · Cited by 154 · cited 2×
“with these sensors can be mounted into chest belts [40]–[43], or applied to the skin [44], [45], amongst other modes of attachment.”
BackgroundDeep Neural Networks for Identifying Cough Sounds
Amoh, J., & Odame, K. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2598794 · Cited by 153 · cited 1×
“signal processing and recognition methods such as machine learning classification algorithms, the cough can be identified automatically [147].”
MethodResponding to COVID-19: The UW Medicine Information Technology Services Experience
Grange, E. S., Neil, E. J., Stoffel, M., Singh, A. P., Tseng, E., Resco-Summers, K., Fellner, B. J., Lynch, J. B., Mathias, P. C., Mauritz-Miller, K., et al. (2020) · Applied Clinical Informatics · doi:10.1055/s-0040-1709715 · Cited by 152 · cited 1×
“documentation templates, dashboard metrics, and EMR data [196].”
BackgroundHow does coronavirus kill? Clinicians trace a ferocious rampage through the body, from brain to toes
(2020) · AAAS Articles DO Group · doi:10.1126/science.abc3208 · Cited by 150 · cited 1×
“respiratory failure and hypoxemia, direct myocardial infection resulting from the virus attack of the lining of the heart and blood vessels that are rich in ACE2 receptors [65], indirect injury from”
BackgroundThomas, S. S., Nathan, V., Zong, C., Soundarapandian, K., Shi, X., & Jafari, R. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2458779 · Cited by 140 · cited 1×
“ECG as the proximal and PPG as the distal timing reference [96]–[98].”
Esmaili, A., Kachuee, M., & Shabany, M. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2745081 · Cited by 140 · cited 1×
“Several studies use alternative cardiac signals for ECG, such as impedance plethysmography (IPG) [99], [100], phonocardiogram (PCG) [101], [102], or ballistocardiogram”
BackgroundLi, H., Ma, Y., Liang, Z., Wang, Z., Cao, Y., Xu, Y., Zhou, H., Lu, B., Chen, Y., Han, Z., et al. (2020) · National Science Review · doi:10.1093/nsr/nwaa022 · Cited by 140 · cited 2×
“Wearable/unobtrusive BP monitoring platforms with realization in daily objects: (a) BP watch [121], (b) BP eyeglasses [123], (c) flexible BP patch [129], (d) BP shirt [126], (e) wearable skin-like BP patch [131], (f) near-infrared phototransistor for BP [227], (g) BP chair [128], (h) BP camera [138], and (i) BP sleepi…”
BackgroundLiu, J., Yan, B. P., Zhang, Y.-T., Ding, X.-R., Su, P., & Zhao, N. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2874957 · Cited by 139 · cited 1×
“traditional arterial PTT-based method with better BP estimation accuracy [108].”
MethodSelf-citationGupta, P., Moghimi, M. J., Jeong, Y., Gupta, D., Inan, O. T., & Ayazi, F. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0225-7 · Cited by 133 · cited 1×
“have developed a wearable solution that integrates an accelerometer and a microphone via a nano-gap transducer for longitudinal monitoring of heart and lung sounds as well as relevant parameters including HR, RR, and body motion [58].”
BackgroundEnabling Smart Personalized Healthcare: A Hybrid Mobile-Cloud Approach for ECG Telemonitoring
Wang, X., Gui, Q., Liu, B., Jin, Z., & Chen, Y. Z. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2286157 · Cited by 130 · cited 1×
“Pettigrew’s presentations at the IEEE Life Sciences Grand Challenge Conference held at National Academy of Sciences in 2012) [5-7].”
BackgroundMartin, S. L.-O., Carek, A. M., Kim, C.-S., Ashouri, H., Inan, O. T., Hahn, J.-O., & Mukkamala, R. (2016) · Scientific Reports · doi:10.1038/srep39273 · Cited by 130 · cited 3×
“Such sensors usually work by capacitive sensing using smart materials like e-textiles or by measuring the mechanical displacement of the body (e.g., ballistocardiogram, BCG); and 2) by using ambient sensors such as cameras to detect the vital signs of a user in a contactless way.”
BackgroundThe importance of respiratory rate monitoring
Rolfe, S. (2019) · British Journal of Nursing · doi:10.12968/bjon.2019.28.8.504 · Cited by 130 · cited 1×
“Being an early, measurable indicator of physiological conditions such as hypoxia (low levels of oxygen) and hypercapnia (high levels of carbon dioxide in the bloodstream), it has also showed to be a strong predictor of acute events such as cardiac arrest and unplanned intensive care admission [37].”
BackgroundZhang, Q., Zhou, D., & Zeng, X. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0317-z · Cited by 129
Characteristic Electrocardiographic Manifestations in Patients With COVID-19
He, J., Wu, B., Chen, Y., Tang, J., Liu, Q., Zhou, S., Chen, C., Qin, Q., Huang, K., Lv, J., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.03.028 · Cited by 124
A New Wearable Device for Blood Pressure Estimation Using Photoplethysmogram
Lazazzera, R., Belhaj, Y., & Carrault, G. (2019) · Sensors · doi:10.3390/s19112557 · Cited by 121 · cited 1×
“An alternative way is to use a wrist watch [134], [135] for daytime monitoring and a sleeping cushion [127] for overnight use (Fig.”
MethodCuffless blood pressure estimation using only a smartphone
Matsumura, K., Rolfe, P. J., Toda, S., & Yamakoshi, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-25681-5 · Cited by 116 · cited 4×
“As an example, a CT mobile platform that is self-contained with automated scanning workflow has been reported for remote diagnosis of patients in temporary mobile cabin hospitals and at the Fangcang Shelter Hospital [112], [182].”
BackgroundInfluentialAcoustic Methods for Pulmonary Diagnosis
Rao, A. A., Huynh, E., Royston, T. J., Kornblith, A. E., & Roy, S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2874353 · Cited by 116 · cited 1×
“tified, may provide additional information about the severity and location of the trauma or disease [54].”
BackgroundQRS Detection Algorithm for Telehealth Electrocardiogram Recordings
Khamis, H., Weiss, R., Xie, Y., Chang, C.-W., Lovell, N. H., & Redmond, S. J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2549060 · Cited by 114 · cited 1×
“ings due to the fact that such unsupervised measurements are much more susceptible to being corrupted with noise or through poor measurement technique [174].”
BackgroundSelf-citationBuekers, J., Theunis, J., De Boever, P., Vaes, A. W., Koopman, M., Janssen, E. V., Wouters, E. F., Spruit, M. A., & Aerts, J.-M. (2019) · JMIR mHealth and uHealth · doi:10.2196/12866 · Cited by 112 · cited 1×
“continuous SpO2 measurements to capture significant SpO2 fluctuations over long periods of time that can help determine the clinical relevance of such fluctuations [23].”
BackgroundZhang, Q., Zeng, X., Hu, W., & Zhou, D. (2017) · IEEE Access · doi:10.1109/access.2017.2707472 · Cited by 109 · cited 2×
“Portable medical imaging devices (a) portable ultrasound system (Butterfly) [113], [176], (b) Optima XR220amx portal X ray (GE) [177], (c) BodyTom CT scanner (Samsung) [115], [178], and (d) portable MRI (Hyperfine) [166], [179].”
BackgroundEstimation of Respiration Rate from Three-Dimensional Acceleration Data Based on Body Sensor Network
Liu, G.-Z., Guo, Y.-W., Zhu, Q.-S., Huang, B.-Y., & Wang, L. (2011) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0022 · Cited by 107 · cited 1×
“estimation can be obtained during various activities such as walking, running and sleeping [42].”
BackgroundMulti-wavelength photoplethysmography method for skin arterial pulse extraction
Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004313 · Cited by 107 · cited 1×
“To improve the user comfort, a peripheral PTT-based multi-wavelength method has been proposed using two or multiple PPG sensors [105]–[107].”
MethodSelf-citationGlabella: Continuously Sensing Blood Pressure Behavior using an Unobtrusive Wearable Device
Holz, C., & Wang, E. J. (2017) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3132024 · Cited by 106 · cited 1×
“mented into wearable and unobtrusive devices, such as watch [121], glasses [122], [123], a wrist/armband [99], [124], [125], shirt [126], sleeping cushion [127], chair [128], smartphone”
BackgroundObjective Study of Sensor Relevance for Automatic Cough Detection
Drugman, T., Urbain, J., Bauwens, N., Chessini, R., Valderrama, C. A., Lebecque, P., & Dutoit, T. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2239303 · Cited by 105 · cited 1×
“phone that can be wearable or placed near the user, or a piezoelectric transducer and high-sensitivity accelerometer that can be placed at the throat or the thoracic area [146]–[148].”
BackgroundSeismoWatch: Wearable Cuffless Blood Pressure Monitoring Using Pulse Transit Time
Carek, A. M., Conant, J., Joshi, A., Kang, H., & Inan, O. T. (2017) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3130905 · Cited by 103 · cited 1×
“An alternative way is to use a wrist watch [134], [135] for daytime monitoring and a sleeping cushion [127] for overnight use (Fig.”
MethodA Non-Invasive Continuous Blood Pressure Estimation Approach Based on Machine Learning
Chen, S., Ji, Z., Wu, H., & Xu, Y. (2019) · Sensors · doi:10.3390/s19112585 · Cited by 103 · cited 1×
“estimation to develop regression models between signal features and BP, and demonstrating promising estimation accuracy [115-120].”
Effective strategies to prevent coronavirus disease-2019 (COVID-19) outbreak in hospital
Lee, I.-K., Wang, C.-C., Mc, L., Kung, C.-T., Lan, K.-C., & Ct, L. (2020) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.02.022 · Cited by 102 · cited 1×
“The infrared thermal camera is one of the most well-known unobtrusive technologies being used in the COVID-19 pandemic, to recognize any persons with fever at the hospital entrance or public places like airports [151].”
MethodAn Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry
Haahr, R. G., Duun, S. B., Toft, M. H., Belhage, B., Larsen, J., Birkelund, K., & Thomsen, E. V. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2164247 · Cited by 100 · cited 1×
“presented a patch SpO2 monitor that used an annular backside silicon photodiode can decrease the power consumption of the oximeter sensor [32].”
MethodTextile‐Enabled Highly Reproducible Flexible Pressure Sensors for Cardiovascular Monitoring
Luo, N., Zhang, J., Ding, X., Zhou, Z., Zhang, Q., Zhang, Y., Chen, S., Hu, J., & Zhao, N. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700222 · Cited by 96 · cited 2×
“[112], camera and flexible patch [114], [129], [130] as summarized in Fig.”
BackgroundSelf-citationRobust Detection of Audio-Cough Events Using Local Hu Moments
Monge-Alvarez, J., Hoyos-Barcelo, C., Lesso, P., & Casaseca-de-la-Higuera, P. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2800741 · Cited by 96 · cited 1×
“automatic cough detection, and demonstrated the sensitivity and specificity of cough detection as high as 88% and 99% in various environments [150].”
BackgroundA Chair–Based Unobtrusive Cuffless Blood Pressure Monitoring System Based on Pulse Arrival Time
Tang, Z., TAMURA, T., Sekine, M., Huang, M., Chen, W., Yoshida, M., Sakatani, K., Kobayashi, H., & Kanaya, S. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2614962 · Cited by 95 · cited 2×
“mented into wearable and unobtrusive devices, such as watch [121], glasses [122], [123], a wrist/armband [99], [124], [125], shirt [126], sleeping cushion [127], chair [128], smartphone”
BackgroundSelf-citationHigh-Throughput, Contact-Free Detection of Atrial Fibrillation From Video With Deep Learning
Yan, B. P., Lai, W. H. S., Chan, C. K. Y., Au, A. C. K., Freedman, B., Poh, Y. C., & Poh, M.-Z. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2019.4004 · Cited by 94 · cited 1×
“Another recent work by Yan and the colleagues demonstrated a camera-based facial PPG that can detect AF from multiple patients using a deep convolutional neural network algorithm [154].”
BackgroundJing, Z., Zhu, H.-D., Yan, X., Chai, W., & Zhang, S. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa258 · Cited by 93 · cited 1×
“recommendations for the management of AMI inside medical centers on the basis of their clinical experience in treating patients with COVID-19 [220].”
BackgroundKapoor, A., Pandurangi, U. M., Arora, V., Gupta, A. K., Jaswal, A., Nabar, A., Naik, A. M., Naik, N., Namboodiri, N., Vora, A. M., et al. (2020) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2020.04.003 · Cited by 92 · cited 3×
“Such mobile technology is also recommended by the Indian Heart Rhythm Society for a similar purpose of monitoring drug interactions on QTc [173].”
BackgroundEpidermal electronics for respiration monitoring via thermo-sensitive measuring
Liu, Y., Zhao, L., Avila, R. O., Yiu, C. K., Wong, T., Chan, Y., Yao, K., Li, D., Zhang, Y., Li, W., et al. (2020) · Materials Today Physics · doi:10.1016/j.mtphys.2020.100199 · Cited by 91 · cited 4×
“Wearable RR monitor products: (a) Spire medical health tag (Spire Health, USA) [47], RespiraSenseTM patch (PMD Solutions, Ireland) [48], and MonBaby clip (MonBaby, New York, USA) [49], (b) ZephyrTM garment (Zephyr Technology, Auckland, New Zealand) [50], and state-of-the-art research, (c) an epidermal thermal sensor […”
BackgroundMethodInfluentialSelf-citationHow Should the Rehabilitation Community Prepare for 2019-nCoV?
Koh, G. C., & Hoenig, H. (2020) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2020.03.003 · Cited by 90 · cited 1×
“, position management, physical exercise, respiratory management and psychological intervention [198], [199].”
BackgroundTreskes, R. W., van Winden, L. A. M., van Keulen, N., van der Velde, E. T., Beeres, S. L. M. A., Atsma, D. E., & Schalij, M. J. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.2165 · Cited by 90 · cited 1×
“has investigated the effect of such mHealth technology on managing patients with AMI, and demonstrated feasibility and overall patient acceptance of such smart technology [221].”
BackgroundHtun, T. P., Sun, Y., Chua, H. L., & Pang, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-44145-y · Cited by 89 · cited 1×
“rate > 100 beats per min with iv) crackles obtained via stethoscope [15, 18].”
MethodGao, M., Olivier, N. B., & Mukkamala, R. (2016) · Physiological Reports · doi:10.14814/phy2.12768 · Cited by 86 · cited 1×
“To improve the user comfort, a peripheral PTT-based multi-wavelength method has been proposed using two or multiple PPG sensors [105-107].”
MethodA Wearable Thermometry for Core Body Temperature Measurement and Its Experimental Verification
Huang, M., TAMURA, T., Tang, Z., Chen, W., & Kanaya, S. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2532933 · Cited by 81 · cited 2×
“Wearable temperature monitoring: (a) TempTraq temperature Bluetooth-enabled patch [145], (b) headband thermometry [143].”
MethodSelf-citationKindle, R. D., Badawi, O., Celi, L. A., & Sturland, S. (2019) · Critical Care Clinics · doi:10.1016/j.ccc.2019.02.005 · Cited by 81 · cited 1×
“comprehensive datasets is essential, of which the standardized data collection and procession is of comparable importance [193].”
BackgroundA Wireless Respiratory Monitoring System Using a Wearable Patch Sensor Network
Elfaramawy, T., Fall, C. L., Arab, S., Morissette, M., Lellouche, F., & Gosselin, B. J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877617 · Cited by 80 · cited 1×
“phone that can be wearable or placed near the user, or a piezoelectric transducer and high-sensitivity accelerometer that can be placed at the throat or the thoracic area [146]–[148].”
BackgroundYang, F., Liu, N., Wu, J., Hu, L., Su, G. S., Zheng, N., & Zheng, Z. G. (2020) · PubMed · doi:10.3760/cma.j.issn.1001-0939.2020.0004 · Cited by 77 · cited 1×
“, simple, safe, satisfy, save, in particular to prevent the spread of virus through droplets [201].”
BackgroundHui, H., Zhang, Y., Yang, X., Wang, X., He, B., Li, L., Li, H., Tian, J., & Chen, Y. (2020) · medRxiv · doi:10.1101/2020.02.24.20027052 · Cited by 76 · cited 1×
“to an ICU [17], and patients with an SpO2 lower than 90% during admission are more likely to die [22].”
BackgroundSelf-citationKlum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R. (2020) · Sensors · doi:10.3390/s20072033 · Cited by 75 · cited 1×
“different places of the body [59], [60].”
Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System
Rachim, V. P., & Chung, W. (2019) · Scientific Reports · doi:10.1038/s41598-019-44348-3 · Cited by 73 · cited 1×
“mented into wearable and unobtrusive devices, such as watch [121], glasses [122], [123], a wrist/armband [99], [124], [125], shirt [126], sleeping cushion [127], chair [128], smartphone”
BackgroundZhang, Y.-T., Poon, C. C. Y., Chan, C.-H., Tsang, M. W. W., & Wu, K.-F. (2006) · 2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors · doi:10.1109/issmdbs.2006.360104 · Cited by 72 · cited 2×
“mented into wearable and unobtrusive devices, such as watch [121], glasses [122], [123], a wrist/armband [99], [124], [125], shirt [126], sleeping cushion [127], chair [128], smartphone”
BackgroundSelf-citationBartolo, M., Intiso, D., Lentino, C., Sandrini, G., Paolucci, S., Zampolini, M., & The Board of the Italian Society of Neurological Rehabilitation (SIRN) (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00423 · Cited by 68 · cited 1×
“To promote physical exercise as an example, patients with mild to moderate symptoms can, for example, use posture and movement monitoring technologies, such as depth-cameras or wearable systems [203-205].”
BackgroundInskip, J. A., Lauscher, H. N., LI, L. C., Dumont, G. A., Garde, A., Ho, K., Hoens, A. M., ROAD, J. D., Ryerson, C. J., & Camp, P. G. (2017) · Chronic Respiratory Disease · doi:10.1177/1479972317709643 · Cited by 65 · cited 1×
“such as depth-cameras or wearable systems [203]–[205].”
Tao, X., Huang, T.-H., Shen, C., Ko, Y., Jou, G.-T., & Končar, V. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700309 · Cited by 65 · cited 1×
“As an exemplar, an e-textile based stretchable electrodes connected with an electronic module that was made on a flexible print circuit were developed and integrated to a sportswear [83].”
MethodAn Efficient Motion-Resistant Method for Wearable Pulse Oximeter
Yan, Y.-S., & Zhang, Y.-T. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.902173 · Cited by 62 · cited 1×
“than the clinically verified motion-resistant algorithm – discrete saturate transform – when signal quality is low [28].”
BackgroundSelf-citationA Thermal Camera Based Continuous Body Temperature Measurement System
Lin, J.-W., Lu, M.-H., & Lin, Y. (2019) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2019.00208 · Cited by 61 · cited 1×
“applying deep learning based face detection and object tracking algorithms [152].”
MethodEstimating the instant case fatality rate of COVID-19 in China
Mi, Y., Huang, T., Zhang, J., Qin, Q., Gong, Y.-X., Liu, S., Xue, H.-M., Ning, C.-H., Cao, L., & Cao, Y.-X. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.04.055 · Cited by 61 · cited 1×
“the most-affected countries [1]–[3], and it is an acute public health issue.”
BackgroundHansen, H., Bieler, T., Beyer, N., Godtfredsen, N. S., Kallemose, T., & Frølich, A. (2017) · BMC Pulmonary Medicine · doi:10.1186/s12890-017-0488-1 · Cited by 60 · cited 1×
“It is noteworthy that the educational videos and instruction manuals in an e-consultation platform should be elaborately prepared and the real-time supervision is recommended to support patient conduct of tele-PR in an effective and safe way [202].”
BackgroundSmith, W., Riddell, F., Madon, M., & Gleva, M. J. (2016) · American Heart Journal · doi:10.1016/j.ahj.2016.11.006 · Cited by 59 · cited 1×
“Similarly, the CAM Patch has been announced for use in monitoring QT interval in patients who have been treated with hydroxychloroquine [75], [76].”
BackgroundYousefian, P., Shin, S., Mousavi, A. S., Kim, C., Mukkamala, R., Jang, D.-G., Ko, B.-H., Lee, J., Kwon, U.-K., Kim, Y. H., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-46936-9 · Cited by 59 · cited 3×
“Such sensors usually work by capacitive sensing using smart materials like e-textiles or by measuring the mechanical displacement of the body (e.g., ballistocardiogram, BCG); and 2) by using ambient sensors such as cameras to detect the vital signs of a user in a contactless way.”
BackgroundSoroudi, A., Hernández, N., Wipenmyr, J., & Nierstrasz, V. A. (2019) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-019-02047-9 · Cited by 59 · cited 1×
“, by implementing an electro-conductive elastic paste between skin and electrode [85].”
MethodCoping with COVID-19: scaling up virtual care to standard practice
Barsom, E. Z., Feenstra, T. M., Bemelman, W. A., Bonjer, H. J., & Schijven, M. P. (2020) · Nature Medicine · doi:10.1038/s41591-020-0845-0 · Cited by 58 · cited 1×
“With virtual care such as video consultation [164] and further through remote monitoring of the health status of patients, delivery of interventions and treatment to patients at home, the care can be shifted from hospital to improvised hospital, community and home.”
BackgroundSubbe, C. P., & Kinsella, S. (2018) · Sensors · doi:10.3390/s18082700 · Cited by 57
Yamamoto, A., Nakamoto, H., Bessho, Y., Watanabe, Y., Oki, Y., Ono, K., Fujimoto, Y., Terada, T., & Ishikawa, A. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02062-2 · Cited by 56 · cited 1×
“with these sensors can be mounted into chest belts [40]–[43], or applied to the skin [44], [45], amongst other modes of attachment.”
BackgroundY. Poon, C., Wong, Y., & Zhang, Y.-T. (2006) · 2006 IEEE/NLM Life Science Systems and Applications Workshop · doi:10.1109/lssa.2006.250377 · Cited by 55 · cited 2×
“mented into wearable and unobtrusive devices, such as watch [121], glasses [122], [123], a wrist/armband [99], [124], [125], shirt [126], sleeping cushion [127], chair [128], smartphone”
BackgroundSelf-citationRepetitive neural network (RNN) based blood pressure estimation using PPG and ECG signals
Şentürk, Ü., Yücedağ, İ., & Polat, K. (2018) · International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT) · doi:10.1109/ismsit.2018.8567071 · Cited by 55 · cited 1×
“mation to develop regression models between signal features and BP, and demonstrating promising estimation accuracy [115]– [120].”
BackgroundCOVID-19 Clinical Guidance For the Cardiovascular Care Team
Maddox, T. M., Stecker, E. C., Bozkurt, B., DeMichelis, N., Doherty, J. U., Freeman, A. M., Gluckman, T. J., Itchhaporia, D., Miller, A. P., Price, A., et al. (2020) · Cited by 55
Huang, Y., Meng, S., Zhang, Y., Wu, S., Zhang, Y., Zhang, Y., Ye, Y., Wei, Q., Zhao, N., Jiang, J., et al. (2020) · medRxiv · doi:10.1101/2020.04.07.20051060 · Cited by 46 · cited 1×
“where there is currently an overall lack of clinical studies on respiratory sounds, a study has investigated lung sounds on patients with confirmed COVID-19 by lung auscultation, and shown that all patients (n = 10) were found to have abnormal respiratory sounds [55].”
BackgroundSelf-citationAl-Halhouli, A. T., Al‐Ghussain, L., Bouri, S. E., Habash, F., Liu, H., & Zheng, D. (2020) · Applied Sciences · doi:10.3390/app10020480 · Cited by 45 · cited 2×
“Wearable RR monitor products: (a) Spire medical health tag (Spire Health, USA) [47], RespiraSenseTM patch (PMD Solutions, Ireland) [48], and MonBaby clip (MonBaby, New York, USA) [49], (b) ZephyrTM garment (Zephyr Technology, Auckland, New Zealand) [50], and state-of-the-art research, (c) an epidermal thermal sensor […”
BackgroundChacon, P. J., Pu, L., da Costa, T. H., Shin, Y.-H., Ghomian, T., Shamkhalichenar, H., Wu, H., Irving, B. A., & Choi, J. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2874885 · Cited by 44 · cited 22×
“The iPPG can indicate the local changes of dermal blood volume, and can be used to estimate physiological parameters including HR, SpO2, RR and BP [138], [153].”
MethodInfluentialNon-invasive blood pressure estimation using phonocardiogram
Dastjerdi, A. E., Kachuee, M., & Shabany, M. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050240 · Cited by 41 · cited 2×
“Several studies use alternative cardiac signals for ECG, such as impedance plethysmography (IPG) [99], [100], phonocardiogram (PCG) [101], [102], or ballistocardiogram (BCG) [103], [104].”
BackgroundGabriels, J., Saleh, M., Chang, D., & Epstein, L. M. (2020) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2020.03.017 · Cited by 40 · cited 1×
“to monitor the ECG changes of patients treated with hydroxychloroquine and azithromycin [74].”
BackgroundAI in the ICU: In the intensive care unit, artificial intelligence can keep watch
Gholami, B., Haddad, W. M., & Bailey, J. M. (2018) · IEEE Spectrum · doi:10.1109/mspec.2018.8482421 · Cited by 38 · cited 1×
“identifying types of ventilator asynchrony, and adaptive control of ventilators [192].”
BackgroundYernault, J., & Bohadana, A. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08101756 · Cited by 38 · cited 1×
“Structural changes induced by disease cause alterations in acoustic transmission of frequencies through the thoracic cavity [52], [53].”
BackgroundDesign of a Wearable 12-Lead Noncontact Electrocardiogram Monitoring System
Hsu, C.-C., Lin, B.-S., He, K.-Y., & Lin, B. (2019) · Sensors · doi:10.3390/s19071509 · Cited by 37 · cited 1×
“the locations of the electrodes can be adjusted [84].”
BackgroundWang, Y., Lu, X., Zhang, Y., Zhang, X., Wang, K., Liu, J., Li, X., Hu, R., Meng, X., Dou, S., et al. (2020) · EBioMedicine · doi:10.1016/j.ebiom.2020.102724 · Cited by 37 · cited 2×
“Intelligent CT performance testing, (a)–(d) full automatic results, (e)–(h) manual results, and (i)–(j) comparison of the scanning length error and radiation dose among the full, semi and manual scenarios [183].”
BackgroundMethodSelf-citationWearable Multimodal Stethoscope Patch for Wireless Biosignal Acquisition and Long-Term Auscultation
Klum, M., Leib, F., Oberschelp, C., Martens, D., Pielmuş, A.-G., Tigges, T., Penzel, T., & Orglmeister, R. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857210 · Cited by 36 · cited 1×
“different places of the body [59], [60].”
Tonino, R. P. B., Larimer, K. A., Eissen, O., & Schipperus, M. R. (2019) · JMIR Human Factors · doi:10.2196/15103 · Cited by 34 · cited 3×
“Other ECG patch products with a similar function have been used in clinical studies including ZioXT (iRhythm, California, USA), NUVANT (Corventis, California, USA), Savvy monitor (Ljubljana, Slovenia) [77], and the SEEQ MCT patch (Medtronic, Inc) [78], VitalPatch wearable sensor (VitalConnect, California, USA) [79] (F…”
AUSCULTATORY PERCUSSION OF THE CHEST
Guarino, J. R. (1980) · The Lancet · doi:10.1016/s0140-6736(80)91788-2 · Cited by 33 · cited 1×
“Structural changes induced by disease cause alterations in acoustic transmission of frequencies through the thoracic cavity [52], [53].”
BackgroundGu, W. B., Poon, C. C. Y., Leung, H. K., Sy, M. Y., Wong, M. Y. M., & Zhang, Y. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335393 · Cited by 32 · cited 4×
“mented into wearable and unobtrusive devices, such as watch [121], glasses [122], [123], a wrist/armband [99], [124], [125], shirt [126], sleeping cushion [127], chair [128], smartphone”
BackgroundMethodInfluentialSelf-citationContinuous Health Monitoring With Resonant-Microphone-Array-Based Wearable Stethoscope
Shkel, A. A., & Kim, E. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2900713 · Cited by 32 · cited 1×
“implemented a resonant microphone array that could counteract the interference from the heart and external noise sources, thus reducing the digital processing of the acquired signals, reducing power consumption and improving the detection accuracy [61].”
BackgroundDetection of atrial fibrillation using a smartwatch
Chon, K. H., & McManus, D. D. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0057-1 · Cited by 29 · cited 1×
“been widely for cardiovascular monitoring, including HR measurement and AF detection [90].”
Harvey, J. R., Salehizadeh, S. M. A., Mendelson, Y., & Chon, K. H. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2837499 · Cited by 29 · cited 1×
“76% for SpO2 measurements with motion artefacts and at low oxygen level [31].”
BackgroundA Novel High-Resolution Method for the Respiration Rate and Breathing Waveforms Remote Monitoring
Vaǐner, B. G. (2018) · Annals of Biomedical Engineering · doi:10.1007/s10439-018-2018-6 · Cited by 28 · cited 1×
“Vainer proposed an approach which integrated infrared thermography with chemical physics to provide a high-resolution noncontact evaluation of RR and breathing waveforms [155].”
MethodMulti-channel pulse oximetry for wearable physiological monitoring
Mendelson, Y., Dao, D. K., & Chon, K. H. (2013) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2013.6575518 · Cited by 27 · cited 1×
“proved to be efficient for robust noise cancellation with PPG signal acquired concurrently from each channel [29].”
BackgroundArathy, R., Nabeel, P. M., Joseph, J., & Sivaprakasam, M. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab1a82 · Cited by 27 · cited 3×
“Apart from the PTT-based BP estimation method, some other physiological features have been investigated to indicate BP changes, including PPG intensity ratio [109], Womersley number [110], radial electrical bioimpedance [111], modified normalized pulse volume [112], acceleration plethysmography (APG) [113], and diamet…”
BackgroundModified RGB Cameras for Infrared Remote-PPG
Wang, W., & Brinker, A. C. D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2973313 · Cited by 26 · cited 2×
“Similarly, the CAM Patch has been announced for use in monitoring QT interval in patients who have been treated with hydroxychloroquine [75], [76].”
BackgroundMethodWrist Photo-Plethysmography and Bio-Impedance Sensor for Cuff-Less Blood Pressure Monitoring
Rachim, V. P., Huynh, T. H., & Chung, W. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589559 · Cited by 25 · cited 3×
“Several studies use alternative cardiac signals for ECG, such as impedance plethysmography (IPG) [99], [100], phonocardiogram (PCG) [101], [102], or ballistocardiogram (BCG) [103], [104].”
BackgroundA ring-type device for the noninvasive measurement of arterial blood pressure
Zheng, D., & Zhang, Y. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280819 · Cited by 23
Self-citationProjecting Critical Care Beyond the ICU: An Analysis of Tele-ICU Support for Rapid Response Teams
Pappas, P. A., Tirelli, L., Shaffer, J., & Gettings, S. (2016) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0098 · Cited by 23 · cited 1×
“eMobile platform (Health First hospitals) [190].”
Vardas, P. E., Cowie, M., Dagres, N., Asvestas, D., Tzeis, S. E., Vardas, E. P., Hindricks, G., & Camm, A. J. (2019) · EP Europace · doi:10.1093/europace/euz249 · Cited by 23 · cited 1×
“Compared with multi-lead ECGs, the one-lead ECG can only provide a limited value for diagnosis of specific cardiac disease, such as myocardial ischaemia [82].”
BackgroundPatel, P., Ordúñez, P., Connell, K., Lackland, D., & DiPette, D. J. (2018) · Southern Medical Journal · doi:10.14423/smj.0000000000000776 · Cited by 22 · cited 1×
“accounting for more than 10 million largely preventable deaths worldwide each year [91].”
BackgroundThambiraj, G., Gandhi, U., Devanand, V., & Umapathy, M. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab1f17 · Cited by 22 · cited 1×
“other physiological features have been investigated to indicate BP changes, including PPG intensity ratio [109], Womersley number [110], radial electrical bioimpedance [111], modified”
BackgroundNoncontact Blood Pressure Monitoring Technology using Facial Photoplethysmograms
Adachi, Y., Edo, Y., Ogawa, R., Tomizawa, R., Iwai, Y., & Okumura, T. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856439 · Cited by 19 · cited 2×
“The iPPG can indicate the local changes of dermal blood volume, and can be used to estimate physiological parameters including HR, SpO2, RR and BP [138], [153].”
BackgroundMethodCardiac and arrhythmic complications in Covid-19 patients.Preprint
Kochi, A. N. (2020) · doi:10.22541/au.158594433.36475644 · Cited by 19 · cited 1×
“, chloroquine and hydroxychloroquine are known to prolong the QT interval which can potentially lead to fatal side effects [72].”
BackgroundFacing highly infectious diseases: new trends and current concepts
Brouqui, P. (2009) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2009.02873.x · Cited by 18 · cited 1×
“the deterioration can pose great challenges to the current critical care setting, in terms of the demand on medical resources and the safety of medical staff [184].”
BackgroundTey, C.-K., An, J., & Chung, W. (2017) · Computational and Mathematical Methods in Medicine · doi:10.1155/2017/5823740 · Cited by 17 · cited 1×
“such as depth-cameras or wearable systems [203]–[205].”
Trobec, R., Tomašić, I., Rashkovska, A., Depolli, M., & Avbelj, V. (2017) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-59340-1_6 · Cited by 17 · cited 2×
“Other ECG patch products with a similar function have been used in clinical studies including ZioXT (iRhythm, California, USA), NUVANT (Corventis, California, USA), Savvy monitor (Ljubljana, Slovenia) [77], and the SEEQ MCT patch (Medtronic, Inc) [78], VitalPatch wearable sensor (VitalConnect, California, USA) [79] (F…”
MethodWearable Digital Thermometer Improves Fever Detection
Abbasi, J. (2017) · JAMA · doi:10.1001/jama.2017.10248 · Cited by 17 · cited 1×
“in body temperature earlier than standard monitoring [141].”
BackgroundImpact of Intensive Care Unit Telemedicine on Outcomes
Kopec, I. C. (2019) · Critical Care Clinics · doi:10.1016/j.ccc.2019.02.002 · Cited by 16 · cited 1×
“The value of tele-ICU depends on the model to be leveraged within the current clinical settings, practices, and medical/personnel resources [194].”
MethodRubin, G. A., BIVIANO, A. B., Dizon, J. M., Yarmohammadi, H., EHLERT, F. A., Saluja, D. S., Rubin, D. A., Morrow, J., Waase, M., Berman, J. P., et al. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14493 · Cited by 16 · cited 1×
“telemedicine solutions made for patients with other cardiovascular conditions including heart failure andcongenital heart disease [222-226].”
BackgroundPerioperative measurement of core body temperature using an unobtrusive passive heat flow sensor
Atallah, L., Ciuhu, C., Paulussen, I., Bongers, E., Blom, A. H. M., Idrissi, A., & Noordergraaf, G. J. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00446-1 · Cited by 14 · cited 2×
“Wearable temperature monitoring: (a) TempTraq® temperature Bluetooth-enabled patch [145], (b) foam-based flexible thermal sensor [144], (c) epidermal wireless thermal sensor array [142], and (d) headband thermometry [143].”
BackgroundMethodNon-contact infrared thermometers
Vernon, G. (2014) · British Journal of General Practice · doi:10.3399/bjgp14x682669 · Cited by 13
The Evolution of Tele-ICU to Tele-Critical Care*
Lilly, C. M., & Greenberg, B. D. (2020) · Critical Care Medicine · doi:10.1097/ccm.0000000000004276 · Cited by 13 · cited 1×
“risk with timely intervention, thus preventing ICU overloading in a pandemic like COVID-19 [195].”
BackgroundNoninvasive continuous blood pressure estimation with peripheral pulse transit time
Li, Y., Chen, X., Zhang, Y., & Deng, N. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833726 · Cited by 12 · cited 1×
“To improve the user comfort, a peripheral PTT-based multi-wavelength method has been proposed using two or multiple PPG sensors [105]–[107].”
MethodSelf-citationHuynh, T. H. (2017) · Cited by 7
Lu, X., Guiraud, D., Renaux, S., Similowski, T., & Coste, C. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856440 · Cited by 7 · cited 1×
“sound from abnormal ones, thus aiding diagnosis of pulmonary disorders or evaluation of ventilation [57].”
BackgroundPilot Development of BP-Glass for Unobtrusive Ambulatory Blood Pressure Monitoring
Zhang, Q., Hu, G., Yan, X., Chin, K. Y., Strangman, G. E., Zhao, N., & Zhang, Y. (2015) · Iproceedings · doi:10.2196/iproc.4691 · Cited by 4 · cited 3×
“mented into wearable and unobtrusive devices, such as watch [121], glasses [122], [123], a wrist/armband [99], [124], [125], shirt [126], sleeping cushion [127], chair [128], smartphone”
BackgroundMethodSelf-citationShareghi, S., Tavakol, M., Lindborg, K. A., Vives, C. A., & Spaccavento, L. J. (2016) · Circulation · Cited by 3
Research works printed but not linked: 2
- 10.1056/CAT.20.0080 · doi:10.1056/cat.20.0080
- katz, 2018, Is telemedicine the future of care?, AARP Mag
Cited by
Use of Telehealth During the COVID-19 Pandemic: Scoping Review
Doraiswamy, S., Abraham, A., Mamtani, R., & Cheema, S. (2020) · Journal of Medical Internet Research · doi:10.2196/24087 · Cited by 698
“It is interesting to note that telehealth has been complemented by the use of wearable devices and selfcare equipment, such as glucometers, handheld blood pressure monitors, pulse oximeters, and digital stethoscopes [35,36].”
Digital health for aging populations
Chen, C., Ding, S., & Wang, J. (2023) · Nature Medicine · doi:10.1038/s41591-023-02391-8 · Cited by 491
Canali, S., Schiaffonati, V., & Aliverti, A. (2022) · PLOS Digital Health · doi:10.1371/journal.pdig.0000104 · Cited by 378
“In this way, wearables can deliver a significant improvement to remote and tele-monitoring [10,11] and have been used in this sense to monitor crucial physiological metrics for COVID-19 such as heart rate, physical activity, oxygen saturation, as well as long-term effects [8,12].”
Electronic skin as wireless human-machine interfaces for robotic VR
Liu, Y., Yiu, C., Song, Z., Huang, Y., Yao, K., Wong, T., Zhou, J., Zhao, L., Huang, X., Nejad, S. K., et al. (2022) · Science Advances · doi:10.1126/sciadv.abl6700 · Cited by 304
Self-citationPeng, S., Yu, Y., Wu, S., & Wang, C.-H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c15014 · Cited by 216
Metadata
- Authors
- Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., Xu, K., Jiang, X., Wang, Q., Yin, B., Feng, G., & Zhang, Y.-T.
- Affiliations
- University of Oxford (GB)
- City University of Hong Kong (HK)
- UNSW Sydney (AU)
- Harvard University (US)
- Fudan University (CN)
- United Imaging Intelligence (China) (CN)
- Southern Medical University (CN)
- Philips (Netherlands) (NL)
- Tongji University (CN)
- Philips (China) (CN)
- ORCID
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2021
- Volume
- 14
- Pages
- 48-70
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W3025646590
- Cited by
- 281
- References
- 193
- Citations by year
- 2026: 15 · 2025: 24 · 2024: 40 · 2023: 58 · 2022: 57 · 2021: 66
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- green
- research.tue.nl
- Licence
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (submittedVersion, other-oa)
- Funders
- Hong Kong ITC Research Fund
- City University of Hong Kong (2017YFE0112000)
- Hubei Science and Technology Department
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Computer Science › Information Systems › Healthcare during COVID-19 Pandemic
- Keywords
- COVID-19 pandemic, wearable sensors, telemedicine, remote patient monitoring, unobtrusive sensing, disease detection, triage, quarantine monitoring, remote diagnosis, disease prevention
- MeSH terms
- Wearable Electronic Devices, COVID-19, SARS-CoV-2, Delivery of Health Care, Humans, Technology, Telemedicine, Pandemics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.