Mass Spectrometry of Protein Complexes: From Origins to Applications
The DOI matches its Crossref record; 107 of the 107 references it cites were found in a registry or an index.
Abstract
Now routine is the ability to investigate soluble and membrane protein complexes in the gas phase of a mass spectrometer while preserving folded structure and ligand-binding properties. Several recent transformative developments have occurred to arrive at this point. These include advances in mass spectrometry instrumentation, particularly with respect to resolution; the ability to study intact membrane protein complexes released from detergent micelles; and the use of protein unfolding in the gas phase to obtain stability parameters. Together, these discoveries are providing unprecedented information on the compositional heterogeneity of biomacromolecules, the unfolding trajectories of multidomain proteins, and the stability imparted by ligand binding to both soluble and membrane-embedded protein complexes. We review these recent breakthroughs, highlighting the challenges that had to be overcome and the physicochemical insight that can now be gained from studying proteins and their assemblies in the gas phase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A draft map of the human proteome
Kim, M.-S., Pinto, S. M., Getnet, D., Nirujogi, R. S., Manda, S. S., Chaerkady, R., Madugundu, A. K., Kelkar, D. S., Isserlin, R., Jain, S., et al. (2014) · Nature · doi:10.1038/nature13302 · Cited by 2,198 · cited 1×
“The recent landmark publication of a draft map of the human proteome is the result of several developments in mass spectrometry applied to proteomics, in which peptides are sequenced to identify proteins in databases (1).”
BackgroundDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613 · cited 7×
“According to the CRM, a droplet carrying a single protein shrinks by evaporation and fission until the complete removal of solvent, with the droplet charge transferred concomitantly to the protein (Figure 1b) (36).”
BackgroundInfluentialMembrane proteins, lipids and detergents: not just a soap opera
Seddon, A. M., Curnow, P., & Booth, P. J. (2004) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2004.04.011 · Cited by 1,333 · cited 3×
“To study membrane proteins in vitro, investigators can reconstitute them in a variety of systems, such as detergent micelles (85), bicelles (86), liposomes (87), amphipols (88),”
BackgroundOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry
Barber, M., Bordoli, R. S., Sedgwick, R. D., & Tyler, A. N. (1981) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39810000325 · Cited by 1,106
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092 · cited 1×
“For drifttube instruments, this is a direct measurement using the Mason-Schamp equation (76, 80).”
MethodSelf-citationStructural Information from Ion Mobility Measurements: Effects of the Long-Range Potential
Mesleh, M. F., Hunter, J. M., Shvartsburg, A. A., Schatz, G. C., & Jarrold, M. F. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp961623v · Cited by 1,043
Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009 · cited 2×
“The image current produced by the movement of ions around a spindle-like central electrode is monitored and transformed into an m/z ratio using a Fourier transform (58).”
MethodBernstein, S. L., Dupuis, N. F., Lazo, N. D., Wyttenbach, T., Condron, M. M., Bitan, G., Teplow, D. B., Shea, J.-E., Ruotolo, B. T., Robinson, C. V., et al. (2009) · Nature Chemistry · doi:10.1038/nchem.247 · Cited by 918 · cited 2×
“spectrometry has therefore been applied to examine the functional mechanism of complex biological systems, for example, the conformational flexibility of rotary ATPases (16), the intermolecular processes that underlie amyloid formation (17, 18), the gas-phase structure of intrinsically disordered proteins (19, 20), an…”
BackgroundMethodSelf-citationElectrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905 · cited 1×
“Solvent evaporation is also essential as this promotes the Coulombic repulsion between ions as they become increasingly confined in the shrinking droplet (28).”
BackgroundReconstitution of Membrane Proteins in Phospholipid Bilayer Nanodiscs
Ritchie, T. K., Grinkova, Y. V., Bayburt, T. H., Denisov, I. G., Zolnerciks, J. K., Atkins, W. M., & Sligar, S. G. (2009) · Methods in Enzymology · doi:10.1016/s0076-6879(09)64011-8 · Cited by 872
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819 · cited 1×
“Theoretical CCS values can be calculated from protein structure models (82, 83), for example, from crystal structures, which can then be compared to experimental values.”
BackgroundIon formation in MALDI mass spectrometry
Zenobi, R., & Knochenmuss, R. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:5<337::aid-mas2>3.0.co;2-s · Cited by 819 · cited 1×
“First, activation of the matrix gives rise to a hot plume carrying highly ionized matrix ions, and then the analyte in the hot plume is ionized by the highly activated matrix ions (26).”
BackgroundBush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796 · cited 1×
“Instead, a calibration can be formed that relates the CCS values measured on a drift-tube instrument to the arrival times measured under the same traveling-wave instrument conditions as the unknown (81).”
MethodSelf-citationMembrane proteins bind lipids selectively to modulate their structure and function
Laganowsky, A., Reading, E., Allison, T. M., Ulmschneider, M. B., Degiacomi, M. T., Baldwin, A. J., & Robinson, C. V. (2014) · Nature · doi:10.1038/nature13419 · Cited by 781 · cited 7×
“In this approach (14), a model is generated for the unfolding data, with which the original unfolding contour plot can be back-calculated.”
BackgroundMethodInfluentialSelf-citationUnraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735 · cited 3×
“ion evaporation model (31–33) and charge residue model (CRM) (34, 35) are the most widely employed, and recently a chain ejection model for unfolded proteins has been put forward (30).”
BackgroundAn introduction to quadrupole–time‐of‐flight mass spectrometry
Chernushevich, I. V., Loboda, A. V., & Thomson, B. A. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.207 · Cited by 705 · cited 1×
“TOF analyzers are based on the principle that the time taken by ions to travel a known field-free distance, under high vacuum, is directly related to their m/z ratios (41).”
BackgroundField induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Reconstitution of Membrane Proteins into Liposomes
Rigaud, J., & Lévy, D. (2003) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(03)72004-7 · Cited by 614 · cited 1×
“To study membrane proteins in vitro, investigators can reconstitute them in a variety of systems, such as detergent micelles (85), bicelles (86), liposomes (87), amphipols (88),”
BackgroundEvidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Self-citationMacfarlane, R. D., & Torgerson, D. F. (1976) · Science · doi:10.1126/science.1251202 · Cited by 576
Ion activation methods for tandem mass spectrometry
Sleno, L., & Volmer, D. A. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.703 · Cited by 529 · cited 1×
“The collisions with the gas convert some of the ion’s kinetic energy into internal modes (65, 66).”
BackgroundFernandez de la Mora, J. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00601-7 · Cited by 528 · cited 3×
“According to the CRM, a droplet carrying a single protein shrinks by evaporation and fission until the complete removal of solvent, with the droplet charge transferred concomitantly to the protein (Figure 1b) (36).”
BackgroundMethodOrbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511 · cited 2×
“Further development involved a custom-built radiofrequency (RF) generator with reduced frequency of the quadrupole to allow mass selection of greater than 32,000 m/z (46).”
MethodSelf-citationIon mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462 · cited 10×
“Theoretical CCS values can be calculated from protein structure models (82, 83), for example, from crystal structures, which can then be compared to experimental values.”
BackgroundInfluentialAssembly reflects evolution of protein complexes
Levy, E. D., Erba, E. B., Robinson, C. V., & Teichmann, S. A. (2008) · Nature · doi:10.1038/nature06942 · Cited by 419 · cited 1×
“Examples include polydispersity in α-crystallins (51), the assembly pathway of the small heat-shock proteins (52), and the relationship between protein quaternary structure evolution and function (53).”
BackgroundSelf-citationNanoelectrospray—More than just a minimized-flow electrospray ionization source
Juraschek, R., Dülcks, T., & Karas, M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00157-3 · Cited by 415 · cited 1×
“The size of the electrospray droplet for ESI is in the micrometer range, whereas it is believed to be at least 10 orders of magnitude lower for nano-ESI (38).”
BackgroundMobility of gaseous lons in weak electric fields
Mason, E. A., & Schamp, H. W. (1958) · Annals of Physics · doi:10.1016/0003-4916(58)90049-6 · Cited by 415 · cited 1×
“For drifttube instruments, this is a direct measurement using the Mason-Schamp equation (76, 80).”
MethodMass spectrometry of intact membrane protein complexes
Laganowsky, A., Reading, E., Hopper, J. T. S., & Robinson, C. V. (2013) · Nature Protocols · doi:10.1038/nprot.2013.024 · Cited by 409 · cited 5×
“In addition to modifications to mass spectrometer hardware, improvements in sample isolation and preparation have played an important role, opening up unheralded opportunities for the characterization of membrane proteins (13, 14).”
BackgroundMethodInfluentialSelf-citationProtein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408 · cited 3×
“One of the advantages of ESI for the mass spectrometry of proteins is that it can generally be applied to a solution of the protein of interest and can therefore be directly coupled to liquid chromatography (29, 30).”
BackgroundSelf-citationHigh-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392 · cited 1×
“In contrast to Q-TOF mass spectrometers, increased pressure within the source region showed no significant effect on ion transmission (61, 62).”
BackgroundBleiholder, C., Dupuis, N. F., Wyttenbach, T., & Bowers, M. T. (2011) · Nature Chemistry · doi:10.1038/nchem.945 · Cited by 366
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · Science · doi:10.1126/science.267.5203.1483 · Cited by 363
Peptides and Proteins in the Vapor Phase
Jarrold, M. F. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.179 · Cited by 361
Micelles Protect Membrane Complexes from Solution to Vacuum
Barrera, N. P., Di Bartolo, N., Booth, P. J., & Robinson, C. V. (2008) · Science · doi:10.1126/science.1159292 · Cited by 360 · cited 1×
“The seminal work for the noncovalent mass spectrometry of a membrane protein was described in 2008–2009 (93, 94), when a membrane protein complex, containing both soluble and transmembrane subunits, BtuC2D2, a vitamin B12 importer, was successfully maintained intact in the gas phase of a mass spectrometer for the firs…”
BackgroundSelf-citationHoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Interfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Hardman, M., & Makarov, A. A. (2003) · Analytical Chemistry · doi:10.1021/ac0258047 · Cited by 314 · cited 1×
“Introduced as a possible substitute for Fourier transform ion cyclotron resonance with relatively low cost and maintenance, Orbitraps have provided good accuracy and high resolving power for low-m/z ions and are widely employed in proteomics (59, 60).”
BackgroundRobinson, C. V., Chung, E. W., Kragelund, B. B., Knudsen, J., Aplin, R. T., Poulsen, F. M., & Dobson, C. M. (1996) · Journal of the American Chemical Society · doi:10.1021/ja960211x · Cited by 313 · cited 1×
“These studies showed that the interactions between a protein and its ligand are preserved in the gas phase and by the mutation of active-site residues, which resulted in changes to the complex formation, confirming that the interactions were specific and ligand dependent (105).”
BackgroundSelf-citationTandem mass spectrometry: dissociation of ions by collisional activation
Shukla, A. K., & Futrell, J. H. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200009)35:9<1069::aid-jms54>3.0.co;2-c · Cited by 273 · cited 1×
“The collisions with the gas convert some of the ion’s kinetic energy into internal modes (65, 66).”
BackgroundHall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267 · cited 1×
“It is known for soluble proteins that lower charge states tend to favor the retention of the protein structure more than do higher charge states (96, 97).”
BackgroundSelf-citationMass spectrometry: come of age for structural and dynamical biology
Benesch, J. L., & Ruotolo, B. T. (2011) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2011.08.002 · Cited by 264 · cited 1×
“Although these theoretical techniques are generally accurate for relatively small molecules, a correction factor is usually applied for larger structures, such as proteins (84).”
BackgroundZhou, M., Sandercock, A. M., Fraser, C. S., Ridlova, G., Stephens, E., Schenauer, M. R., Yokoi-Fong, T., Barsky, D., Leary, J. A., Hershey, J. W., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801313105 · Cited by 256 · cited 1×
“For example, for the eukaryotic initiation factor 3, gas-phase analyses revealed the exact stoichiometry of the complex (67).”
BackgroundSelf-citationvan den Heuvel, R. H. H., van Duijn, E., Mazon, H., Synowsky, S. A., Lorenzen, K., Versluis, C., Brouns, S. J. J., Langridge, D., van der Oost, J., Hoyes, J., et al. (2006) · Analytical Chemistry · doi:10.1021/ac061039a · Cited by 252 · cited 6×
“Dissociated monomers from protein complexes disrupted by SID are less charged than those ejected by CID and also tend to be more compact and folded-like, which is rarely observed for CID (69, 70).”
BackgroundInfluentialNative ion mobility-mass spectrometry and related methods in structural biology
Konijnenberg, A., Butterer, A., & Sobott, F. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2012.11.013 · Cited by 245 · cited 2×
“Since the development of these mass spectrometry methods for noncovalent protein complexes, QTOF mass analyzers have been commonly used because these instruments are readily customized, such as for modifications to RF generators to promote the selection and transmission of higher m/z ratios (39, 46).”
BackgroundMethodAspects of native proteins are retained in vacuum
Ruotolo, B. T., & Robinson, C. V. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.08.020 · Cited by 235
Self-citationGas-phase ions of solute species from charged droplets of solutions
Nguyen, S., & Fenn, J. B. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609969104 · Cited by 232
Ruotolo, B. T., Hyung, S., Robinson, P. M., Giles, K., Bateman, R. H., & Robinson, C. V. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702161 · Cited by 229
Self-citationTahallah, N., Pinkse, M., Maier, C. S., & Heck, A. J. R. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.275 · Cited by 210 · cited 1×
“This obstacle is overcome by lowering the internal energy of ions by collision with an inert gas such as argon; the transmission of high-mass protein complexes is enhanced by increasing the pressure in the ion source and increasing the vacuum at various stages during the flight path (43).”
BackgroundTime-of-flight mass spectrometers with multiply reflected ion trajectories
Wollnik, H., & Przewloka, M. (1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)85127-n · Cited by 205 · cited 1×
“to peak broadening and decreased resolution (42).”
Electrospray ionization mass spectrometry and ion mobility analysis of the 20S proteasome complex
Loo, J. A., Berhane, B., Kaddis, C. S., Wooding, K. M., Xie, Y., Kaufman, S. L., & Chernushevich, I. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.02.017 · Cited by 203
Amphipols: polymeric surfactants for membrane biology research
Popot, J.-L., Berry, E. A., Charvolin, D., Creuzenet, C., Ebel, C., Engelman, D. M., Fl�tenmeyer, M., Giusti, F., Gohon, Y., Herv�, P., et al. (2003) · Cellular and Molecular Life Sciences (CMLS) · doi:10.1007/s00018-003-3169-6 · Cited by 198 · cited 1×
“To study membrane proteins in vitro, investigators can reconstitute them in a variety of systems, such as detergent micelles (85), bicelles (86), liposomes (87), amphipols (88),”
BackgroundHopper, J. T. S., & Oldham, N. J. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.06.010 · Cited by 197 · cited 2×
“spectrometry has therefore been applied to examine the functional mechanism of complex biological systems, for example, the conformational flexibility of rotary ATPases (16), the intermolecular processes that underlie amyloid formation (17, 18), the gas-phase structure of intrinsically disordered proteins (19, 20), an…”
BackgroundMethodCollisional activation of protein complexes: Picking up the pieces
Benesch, J. L. P. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.11.014 · Cited by 195 · cited 7×
“Dissociated monomers from protein complexes disrupted by SID are less charged than those ejected by CID and also tend to be more compact and folded-like, which is rarely observed for CID (69, 70).”
BackgroundMethodInfluentialStudying 18 MDa Virus Assemblies with Native Mass Spectrometry
Snijder, J., Rose, R. J., Veesler, D., Johnson, J. E., & Heck, A. J. R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201210197 · Cited by 193 · cited 1×
“The success of this approach was demonstrated by the first spectrum of an intact GroEL complex with a molecular mass of 800 kDa (44) and very recently by a study of an 18-MDa virus assembly (45).”
BackgroundSubunit architecture of multimeric complexes isolated directly from cells
Hernández, H., Dziembowski, A., Taverner, T., Séraphin, B., & Robinson, C. V. (2006) · EMBO reports · doi:10.1038/sj.embor.7400702 · Cited by 178 · cited 1×
“This is achieved by first determining the masses of the component subunits, then forming many subcomplexes by disruption of the intact assembly in the solution and gas phases, and subsequently using network algorithms to link these subunits and subcomplexes into multiprotein assemblies (2, 3).”
MethodSelf-citationMass spectrometry of membrane transporters reveals subunit stoichiometry and interactions
Barrera, N. P., Isaacson, S. C., Zhou, M., Bavro, V. N., Welch, A., Schaedler, T. A., Seeger, M. A., Miguel, R. N., Korkhov, V. M., van Veen, H. W., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1347 · Cited by 175 · cited 1×
“The seminal work for the noncovalent mass spectrometry of a membrane protein was described in 2008–2009 (93, 94), when a membrane protein complex, containing both soluble and transmembrane subunits, BtuC2D2, a vitamin B12 importer, was successfully maintained intact in the gas phase of a mass spectrometer for the firs…”
BackgroundSelf-citationCombined Charged Residue-Field Emission Model of Macromolecular Electrospray Ionization
Hogan, C. J., Carroll, J. A., Rohrs, H. W., Biswas, P., & Gross, M. L. (2009) · Analytical Chemistry · doi:10.1021/ac8016532 · Cited by 174 · cited 1×
“A derivative of the CRM model, referred to as the charge carrier field-emission model (37), incorporates the ion evaporation model to allow for the expulsion of charge-carrying ions from the droplet through field emission.”
MethodDetection of the Intact GroEL Chaperonin Assembly by Mass Spectrometry
Rostom, A. A., & Robinson, C. V. (1999) · Journal of the American Chemical Society · doi:10.1021/ja990238r · Cited by 173 · cited 1×
“The success of this approach was demonstrated by the first spectrum of an intact GroEL complex with a molecular mass of 800 kDa (44) and very recently by a study of an 18-MDa virus assembly (45).”
BackgroundSelf-citationMarcoux, J., Wang, S. C., Politis, A., Reading, E., Ma, J., Biggin, P. C., Zhou, M., Tao, H., Zhang, Q., Chang, G., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1303888110 · Cited by 170 · cited 1×
“This development is adding a new dimension to the study of protein assemblies, particularly with respect to modeling novel topological arrangements of subunits (5) and to observing conformational changes in response to various stimuli (6).”
BackgroundSelf-citationHyung, S.-J., Robinson, C. V., & Ruotolo, B. T. (2009) · Chemistry & Biology · doi:10.1016/j.chembiol.2009.02.008 · Cited by 169 · cited 2×
“spectrometry has therefore been applied to examine the functional mechanism of complex biological systems, for example, the conformational flexibility of rotary ATPases (16), the intermolecular processes that underlie amyloid formation (17, 18), the gas-phase structure of intrinsically disordered proteins (19, 20), an…”
BackgroundMethodSelf-citationSnijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168
Do Charge State Signatures Guarantee Protein Conformations?
Hall, Z., & Robinson, C. V. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0393-z · Cited by 167 · cited 1×
“It is known for soluble proteins that lower charge states tend to favor the retention of the protein structure more than do higher charge states (96, 97).”
BackgroundSelf-citationDesolvation of ions and molecules in thermospray mass spectrometry
Schmelzeisen-Redeker, G., Bütfering, L., & Röllgen, F. W. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85004-9 · Cited by 163 · cited 7×
“According to the CRM, a droplet carrying a single protein shrinks by evaporation and fission until the complete removal of solvent, with the droplet charge transferred concomitantly to the protein (Figure 1b) (36).”
BackgroundInfluentialZhang, H., Cui, W., Wen, J., Blankenship, R. E., & Gross, M. L. (2011) · Analytical Chemistry · doi:10.1021/ac200695d · Cited by 160 · cited 1×
“This was used in a top-down electron-capture dissociation study for improved sequence coverage of protein assemblies (54, 55) and to map the location of a ligand-binding site (56, 57).”
MethodA mass spectrometry–based hybrid method for structural modeling of protein complexes
Politis, A., Stengel, F., Hall, Z., Hernández, H., Leitner, A., Walzthoeni, T., Robinson, C. V., & Aebersold, R. (2014) · Nature Methods · doi:10.1038/nmeth.2841 · Cited by 156
Self-citationDetergent-free mass spectrometry of membrane protein complexes
Hopper, J. T. S., Yu, Y. T.-C., Li, D., Raymond, A., Bostock, M., Liko, I., Mikhailov, V., Laganowsky, A., Benesch, J. L. P., Caffrey, M., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2691 · Cited by 155 · cited 1×
“It is possible to use membrane proteins solubilized in nanodiscs, bicelles, and amphipols (92, 99, 100).”
MethodSelf-citationProtein complexes gain momentum
Sobott, F., & Robinson, C. V. (2002) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(02)00400-1 · Cited by 144
Self-citationZhong, Y., Han, L., & Ruotolo, B. T. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201403784 · Cited by 137 · cited 1×
“An extension to the analysis of the features of an unfolding plot investigated the collisional unfolding of proteins in the gas phase (102).”
MethodBoundaries of Mass Resolution in Native Mass Spectrometry
Lössl, P., Snijder, J., & Heck, A. J. R. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0874-3 · Cited by 136 · cited 2×
“Although it is not clear if the issue is one of desolvation or mass resolution (40), it is apparent that the Q-TOF configuration of mass analyzers provides limited resolution for noncovalent complexes, which likely derives from incomplete desolvation.”
BackgroundSurface Induced Dissociation: Dissecting Noncovalent Protein Complexes in the Gas phase
Zhou, M., & Wysocki, V. H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400223t · Cited by 136 · cited 1×
“Surface-induced dissociation (SID) is an alternative activation method emerging as a useful approach to probe the quaternary structure of protein complexes (68).”
MethodIntrinsically Disordered Protein Threads Through the Bacterial Outer-Membrane Porin OmpF
Housden, N. G., Hopper, J. T. S., Lukoyanova, N., Rodríguez‐Larrea, D., Wojdyla, J. A., Klein, A., Kaminska, R., Bayley, H., Saibil, H. R., Robinson, C. V., et al. (2013) · Science · doi:10.1126/science.1237864 · Cited by 132
Self-citationαB-Crystallin Polydispersity Is a Consequence of Unbiased Quaternary Dynamics
Baldwin, A. J., Lioe, H., Robinson, C. V., Kay, L. E., & Benesch, J. L. P. (2011) · Journal of Molecular Biology · doi:10.1016/j.jmb.2011.07.016 · Cited by 132 · cited 1×
“Examples include polydispersity in α-crystallins (51), the assembly pathway of the small heat-shock proteins (52), and the relationship between protein quaternary structure evolution and function (53).”
BackgroundSelf-citationSubunit Architecture of Intact Protein Complexes from Mass Spectrometry and Homology Modeling
Taverner, T., Hernández, H., Sharon, M., Ruotolo, B. T., Matak-Vinković, D., Devos, D., Russell, R. B., & Robinson, C. V. (2008) · Accounts of Chemical Research · doi:10.1021/ar700218q · Cited by 129 · cited 1×
“This is achieved by first determining the masses of the component subunits, then forming many subcomplexes by disruption of the intact assembly in the solution and gas phases, and subsequently using network algorithms to link these subunits and subcomplexes into multiprotein assemblies (2, 3).”
MethodSelf-citationProbing the biophysical interplay between a viral genome and its capsid
Snijder, J., Uetrecht, C., Rose, R. J., Sanchez-Eugenia, R., Marti, G. A., Agirre, J., Guérin, D. M. A., Wuite, G. J. L., Heck, A. J. R., & Roos, W. H. (2013) · Nature Chemistry · doi:10.1038/nchem.1627 · Cited by 127
Morgner, N., Kleinschroth, T., Barth, H., Ludwig, B., & Brutschy, B. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.04.013 · Cited by 126 · cited 1×
“For example, in laser-induced liquid bead ion desorption, a protein is solubilized in detergent, and an infrared laser desorbs the protein from microdroplets (90).”
BackgroundTop-down mass spectrometry of supercharged native protein–ligand complexes
Yin, S., & Loo, J. A. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.06.032 · Cited by 125 · cited 1×
“This was used in a top-down electron-capture dissociation study for improved sequence coverage of protein assemblies (54, 55) and to map the location of a ligand-binding site (56, 57).”
MethodLi, H., Wolff, J. J., Van Orden, S. L., & Loo, J. A. (2014) · Analytical Chemistry · doi:10.1021/ac4033214 · Cited by 118 · cited 1×
“This was used in a top-down electron-capture dissociation study for improved sequence coverage of protein assemblies (54, 55) and to map the location of a ligand-binding site (56, 57).”
MethodMiliotis, T., Kjellstr�m, S., Nilsson, J., Laurell, T., Edholm, L.-E., & Marko-Varga, G. (2000) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(200003)35:3<369::aid-jms944>3.0.co;2-n · Cited by 116 · cited 1×
“There are a few examples in which MALDI, after coupling with liquid chromatography (27), has been used to study mixtures of peptides for protein identification; however, for liquid chromatography mass spectrometry and tandem mass spectrometry analysis, ESI is the dominant choice.”
MethodZhou, M., Jones, C. M., & Wysocki, V. H. (2013) · Analytical Chemistry · doi:10.1021/ac401497c · Cited by 110 · cited 1×
“The technology to carry out SID-coupled mass spectrometry is still under development, but results so far are promising (71).”
Background‘Fast atom bombardment’—A rediscovered method for mass spectrometry
Devienne, F. M., & Roustan, J. C. (1982) · Organic Mass Spectrometry · doi:10.1002/oms.1210170405 · Cited by 102
Zhou, M., Dagan, S., & Wysocki, V. H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201108700 · Cited by 101 · cited 7×
“Dissociated monomers from protein complexes disrupted by SID are less charged than those ejected by CID and also tend to be more compact and folded-like, which is rarely observed for CID (69, 70).”
BackgroundInfluentialZhou, M., Politis, A., Davies, R. B., Liko, I., Wu, K.-J., Stewart, A. G., Stock, D., & Robinson, C. V. (2014) · Nature Chemistry · doi:10.1038/nchem.1868 · Cited by 98 · cited 2×
“F or p er so na l u se o nl y. spectrometry has therefore been applied to examine the functional mechanism of complex biological systems, for example, the conformational flexibility of rotary ATPases (16), the intermolecular processes that underlie amyloid formation (17, 18), the gas-phase structure of intrinsically d…”
BackgroundSelf-citationHydrophobic Protein−Ligand Interactions Preserved in the Gas Phase
Liu, L., Bagal, D., Kitova, E. N., Schnier, P. D., & Klassen, J. S. (2009) · Journal of the American Chemical Society · doi:10.1021/ja9060454 · Cited by 94 · cited 1×
“Work by Klassen and colleagues (106) showed the hydrophobic interactions between a protein and its ligand were retained in transition to the gas phase and, in addition, using ion-mobility measurements, that the protein maintains a folded conformation despite the requisite loss of the aqueous environment.”
BackgroundActivation State-Selective Kinase Inhibitor Assay Based on Ion Mobility-Mass Spectrometry
Rabuck-Gibbons, J. N., Hyung, S., Ko, K. S., Fox, C. C., Soellner, M. B., & Ruotolo, B. T. (2013) · Analytical Chemistry · doi:10.1021/ac4012655 · Cited by 94 · cited 1×
“Based on observing the differences in the transitions between intermediates, a method to distinguish kinase inhibitor types was developed by combining CIU data for ligand-bound, ligand-dissociated, and charge-stripped ions (103).”
MethodIntrinsically Disordered p53 and Its Complexes Populate Compact Conformations in the Gas Phase
Pagel, K., Natan, E., Hall, Z., Fersht, A. R., & Robinson, C. V. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201203047 · Cited by 94 · cited 1×
“spectrometry has therefore been applied to examine the functional mechanism of complex biological systems, for example, the conformational flexibility of rotary ATPases (16), the intermolecular processes that underlie amyloid formation (17, 18), the gas-phase structure of intrinsically disordered proteins (19, 20), an…”
BackgroundSelf-citationStructural basis for hijacking siderophore receptors by antimicrobial lasso peptides
Mathavan, I., Zirah, S., Mehmood, S., Choudhury, H. G., Goulard, C., Li, Y., Robinson, C. V., Rebuffat, S., & Beis, K. (2014) · Nature Chemical Biology · doi:10.1038/nchembio.1499 · Cited by 92
Self-citationNiu, S., Rabuck-Gibbons, J. N., & Ruotolo, B. T. (2013) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2013.06.019 · Cited by 91 · cited 1×
“Similar analyses showed that concanavalin A is stabilized by different sugars, with the rank order of stabilization correlating with binding strengths (101).”
BackgroundThe changing impact of the collision-induced decomposition of ions on mass spectrometry
Jennings, K. R. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00325-0 · Cited by 89 · cited 1×
“The most common method of activation is collisioninduced dissociation (CID) (63), in which ions are accelerated by a voltage potential through a cell containing neutral gas atoms or molecules (64).”
MethodCharge Reduction Stabilizes Intact Membrane Protein Complexes for Mass Spectrometry
Mehmood, S., Marcoux, J., Hopper, J. T. S., Allison, T. M., Liko, I., Borysik, A. J., & Robinson, C. V. (2014) · Journal of the American Chemical Society · doi:10.1021/ja510283g · Cited by 87 · cited 1×
“The same is also true for membrane proteins (98), and fortuitously, the best detergents in terms of ease of removal also yield average charge states that are substantially lower than in other detergents.”
BackgroundSelf-citationThe flight of macromolecular complexes in a mass spectrometer
Sobott, F., McCammon, M. G., Hernández, H., & Robinson, C. V. (2005) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2004.1498 · Cited by 83
Self-citationMorrison, E. A., & Henzler‐Wildman, K. A. (2011) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2011.12.020 · Cited by 82 · cited 1×
“To study membrane proteins in vitro, investigators can reconstitute them in a variety of systems, such as detergent micelles (85), bicelles (86), liposomes (87), amphipols (88),”
BackgroundPerforming native mass spectrometry analysis on therapeutic antibodies
Thompson, N., Rosati, S., & Heck, A. J. R. (2013) · Methods · doi:10.1016/j.ymeth.2013.05.003 · Cited by 79
Politis, A., Park, A. Y., Hall, Z., Ruotolo, B. T., & Robinson, C. V. (2013) · Journal of Molecular Biology · doi:10.1016/j.jmb.2013.04.006 · Cited by 77
Self-citationBorysik, A. J., Hewitt, D., & Robinson, C. V. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401736v · Cited by 73 · cited 1×
“Subsequently, the mechanism of how detergents permit the noncovalent mass spectrometry of membrane protein complexes has been investigated (95).”
BackgroundSelf-citationAnalytical Approaches for Size and Mass Analysis of Large Protein Assemblies
Snijder, J., & Heck, A. J. R. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020015 · Cited by 70 · cited 1×
“In contrast to Q-TOF mass spectrometers, increased pressure within the source region showed no significant effect on ion transmission (61, 62).”
BackgroundMarcoux, J., Politis, A., Rinehart, D., Marshall, D. P., Wallace, M. I., Tamm, L. K., & Robinson, C. V. (2014) · Structure · doi:10.1016/j.str.2014.03.004 · Cited by 66
Self-citationVahidi, S., Stocks, B. B., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac402490r · Cited by 62
Cubrilovic, D., Haap, W. J., Barylyuk, K., Ruf, A., Badertscher, M., Gubler, M., Tetaz, T., Joseph, C., Benz, J., & Zenobi, R. (2013) · ACS Chemical Biology · doi:10.1021/cb4007002 · Cited by 62
Heterogeneity and dynamics in the assembly of the Heat Shock Protein 90 chaperone complexes
Ebong, I.-O., Morgner, N., Zhou, M., Saraiva, M. A., Daturpalli, S., Jackson, S. E., & Robinson, C. V. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1106261108 · Cited by 61 · cited 1×
“Examples include polydispersity in α-crystallins (51), the assembly pathway of the small heat-shock proteins (52), and the relationship between protein quaternary structure evolution and function (53).”
BackgroundSelf-citationAmphipathic Polymers Enable the Study of Functional Membrane Proteins in the Gas Phase
Leney, A. C., McMorran, L. M., Radford, S. E., & Ashcroft, A. E. (2012) · Analytical Chemistry · doi:10.1021/ac302223s · Cited by 57 · cited 2×
“Despite this, it has been shown to be possible to retain folded conformations of membrane proteins introduced to the mass spectrometer in amphipols (100).”
BackgroundMethodStructural MS Pulls Its Weight
Sharon, M. (2013) · Science · doi:10.1126/science.1236303 · Cited by 55
Isoforms of U1-70k Control Subunit Dynamics in the Human Spliceosomal U1 snRNP
Hernández, H., Makarova, O. V., Makarov, E. M., Morgner, N., Muto, Y., Krummel, D. P., & Robinson, C. V. (2009) · PLoS ONE · doi:10.1371/journal.pone.0007202 · Cited by 52 · cited 1×
“For example, the unstructured C-terminal regions of U1-snRNP were removed prior to crystallization of the recombinant complex but are phosphorylated in vivo and were found to affect subunit interactions within the endogenous complex (4).”
BackgroundSelf-citationClarke, D. J., Murray, E., Hupp, T., Mackay, C. L., & Langridge-Smith, P. R. R. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0155-3 · Cited by 42 · cited 1×
“This was used in a top-down electron-capture dissociation study for improved sequence coverage of protein assemblies (54, 55) and to map the location of a ligand-binding site (56, 57).”
MethodChen, F., Gerber, S., Heuser, K., Korkhov, V. M., Lizak, C., Mireku, S. A., Locher, K. P., & Zenobi, R. (2013) · Analytical Chemistry · doi:10.1021/ac4000943 · Cited by 41
Knapman, T. W., Valette, N. M., Warriner, S. L., & Ashcroft, A. E. (2013) · Current Analytical Chemistry · doi:10.2174/1573411011309020004 · Cited by 33
MALDI-TOF Mass Spectrometry Analysis of Amphipol-Trapped Membrane Proteins
Bechara, C., Bolbach, G., Bazzaco, P., Sharma, K. S., Durand, G., Popot, J., Zito, F., & Sagan, S. (2012) · Analytical Chemistry · doi:10.1021/ac301035r · Cited by 32 · cited 2×
“MALDI, however, has been used to study amphipol-trapped membrane proteins (92), but the complexes did not remain intact.”
Method
Cited by
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“DNA [77], protein–drug [78], and protein–protein complexes [79, 80].”
Ultraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules
Brodbelt, J. S., Morrison, L. J., & Santos, I. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00440 · Cited by 295
Proteomic landscape of Alzheimer’s Disease: novel insights into pathogenesis and biomarker discovery
Bai, B., Vanderwall, D., Li, Y., Wang, X., Poudel, S., Wang, H., Dey, K. K., Chen, P.-C., Yang, K., & Peng, J. (2021) · Molecular Neurodegeneration · doi:10.1186/s13024-021-00474-z · Cited by 257
Ion Activation Methods for Peptides and Proteins
Brodbelt, J. S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04563 · Cited by 248
Collision induced unfolding of isolated proteins in the gas phase: past, present, and future
Dixit, S. M., Polasky, D. A., & Ruotolo, B. T. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.010 · Cited by 235
Metadata
- Authors
- Mehmood, S., Allison, T. M., & Robinson, C. V.
- Venue
- Annual Review of Physical Chemistry
- Publisher
- Annual Reviews
- Published
- 2015-04-01
- Volume
- 66
- Issue
- 1
- Pages
- 453-474
- ISSN
- 0066-426X (ISSN-L)
- 1545-1593
- OpenAlex
- W2135590784
- Cited by
- 199
- References
- 107
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.