Injectable Biomedical Devices for Sensing and Stimulating Internal Body Organs
The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
The rapid pace of progress in implantable electronics driven by novel technology has created devices with unconventional designs and features to reduce invasiveness and establish new sensing and stimulating techniques. Among the designs, injectable forms of biomedical electronics are explored for accurate and safe targeting of deep‐seated body organs. Here, the classes of biomedical electronics and tools that have high aspect ratio structures designed to be injected or inserted into internal organs for minimally invasive monitoring and therapy are reviewed. Compared with devices in bulky or planar formats, the long shaft‐like forms of implantable devices are easily placed in the organs with minimized outward protrusions via injection or insertion processes. Adding flexibility to the devices also enables effortless insertions through complex biological cavities, such as the cochlea, and enhances chronic reliability by complying with natural body movements, such as the heartbeat. Diverse types of such injectable implants developed for different organs are reviewed and the electronic, optoelectronic, piezoelectric, and microfluidic devices that enable stimulations and measurements of site‐specific regions in the body are discussed. Noninvasive penetration strategies to deliver the miniscule devices are also considered. Finally, the challenges and future directions associated with deep body biomedical electronics are explained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Altman, G. H., Diaz, F., Jakuba, C., Calabro, T., Horan, R. L., Chen, J., Lu, H., Richmond, J., & Kaplan, D. L. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00353-8 · Cited by 3,458
Hypothalamic-pituitary-adrenal axis, neuroendocrine factors and stress
Tsigos, C., & Chrousos, G. P. (2002) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(02)00429-4 · Cited by 2,822
Nanoparticle-Based Medicines: A Review of FDA-Approved Materials and Clinical Trials to Date
Bobo, D., Robinson, K. J., Islam, J., Thurecht, K. J., & Corrie, S. R. (2016) · Pharmaceutical Research · doi:10.1007/s11095-016-1958-5 · Cited by 2,586
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Self-citationElectronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Self-citationConformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794
Self-citationRestoring Voluntary Control of Locomotion after Paralyzing Spinal Cord Injury
van den Brand, R., Heutschi, J., Barraud, Q., DiGiovanna, J., Bartholdi, K., Huerlimann, M., Friedli, L., Vollenweider, I., Moraud, E. M., Duis, S., et al. (2012) · Science · doi:10.1126/science.1217416 · Cited by 767
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
A brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Self-citationBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Gill, M. L., Grahn, P. J., Calvert, J. S., Linde, M. B., Lavrov, I. A., Strommen, J. A., Beck, L. A., Sayenko, D. G., Van Straaten, M. G., Drubach, D. I., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0175-7 · Cited by 574
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513
Ehlert, U., Gaab, J., & Heinrichs, M. (2001) · Biological Psychology · doi:10.1016/s0301-0511(01)00092-8 · Cited by 510
Spinal cord repair: advances in biology and technology
Courtine, G., & Sofroniew, M. V. (2019) · Nature Medicine · doi:10.1038/s41591-019-0475-6 · Cited by 508
Muscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
Self-citationWenger, N., Moraud, E. M., Gandar, J., Musienko, P., Capogrosso, M., Baud, L., Le Goff, C. G., Barraud, Q., Pavlova, N., Dominici, N., et al. (2016) · Nature Medicine · doi:10.1038/nm.4025 · Cited by 369
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705509114 · Cited by 227
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
Edwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
Beyond the brain: Optogenetic control in the spinal cord and peripheral nervous system
Montgomery, K. L., Iyer, S. M., Christensen, A. J., Deisseroth, K., & Delp, S. L. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad7577 · Cited by 147
Tien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
Fully implantable, battery-free wireless optoelectronic devices for spinal optogenetics
Samineni, V. K., Yoon, J., Crawford, K. E., Jeong, Y. R., McKenzie, K. C., Shin, G., Xie, Z., Sundaram, S. S., Li, Y., Yang, M. Y., et al. (2017) · Pain · doi:10.1097/j.pain.0000000000000968 · Cited by 119
Self-citationXiang, Z., Liu, J., & Lee, C. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.12 · Cited by 100
Shi, Z., Zheng, F., Zhou, Z., Li, M., Fan, Z., Ye, H., Zhang, S., Xiao, T., Chen, L., Tao, T. H., et al. (2019) · Advanced Science · doi:10.1002/advs.201801617 · Cited by 94
Cody, P. A., Eles, J. R., Lagenaur, C. F., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.025 · Cited by 87
Mesh nanoelectronics: seamless integration of electronics with tissues.
Dai, X., Hong, G., Gao, T., & Lieber, C. M. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00547 · Cited by 86
Polymer Fiber Probes Enable Optical Control of Spinal Cord and Muscle Function In Vivo
Lu, C., Froriep, U. P., Koppes, R. A., Canales, A., Caggiano, V., Selvidge, J., Bizzi, E., & Anikeeva, P. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201401266 · Cited by 85
Marcovecchio, M. L., & Chiarelli, F. (2012) · Science Signaling · doi:10.1126/scisignal.2003508 · Cited by 79
Computational assessment of neural probe and brain tissue interface under transient motion.
Polanco, M., Bawab, S., & Yoon, H. (2016) · Biosensors · doi:10.3390/bios6020027 · Cited by 36
Cited by
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
A Bioresorbable Dynamic Pressure Sensor for Cardiovascular Postoperative Care
Ouyang, H., Li, Z., Gu, M., Hu, Y., Xu, L., Jiang, D., Cheng, S., Zou, Y., Deng, Y., Shi, B., et al. (2021) · Advanced Materials · doi:10.1002/adma.202102302 · Cited by 160
Shin, J. H., Kwon, J., Kim, J. U., Ryu, H., Ok, J., Joon Kwon, S., Park, H., & Kim, T.-I. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00164-w · Cited by 123
“There are two reasons for finding an efficient input dimension: (1) An immediate response is only possible if the AI can classify the presence/absence of an ErrP in the shortest possible time from when the EEG is received, and (2) higher input dimensions could worsen the performance of a classification model by fittin…”
BackgroundSelf-citationSong, H., Kim, M., Kim, E., Lee, J., Jeong, I., Lim, K., Ryu, S. Y., Oh, M., Kim, Y., & Park, J. (2024) · BMEMat · doi:10.1002/bmm2.12048 · Cited by 61
Self-citation
Metadata
- Authors
- Jung, Y. H., Kim, J. U., Lee, J. S., Shin, J. H., Jung, W., Ok, J., & Kim, T.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2020-02-27
- Volume
- 32
- Issue
- 16
- Pages
- e1907478-e1907478
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3006839020
- Cited by
- 87
- References
- 63
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.