The DOI matches its Crossref record; 390 of the 390 references it cites were found in a registry or an index.
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Abstract
The microenvironment is indispensable for functionality of various biomacromolecules, subcellular compartments, living cells, and organisms. In particular, physical properties within the biological microenvironment could exert profound effects on both the cellular physiology and pathology, with parameters including the polarity, viscosity, pH, and other relevant factors. There is a significant demand to directly visualize and quantitatively measure the fluctuation in the cellular microenvironment with spatiotemporal resolution. To satisfy this need, analytical methods based on fluorescence probes offer great opportunities due to the facile, sensitive, and dynamic detection that these molecules could enable in varying biological settings from in vitro samples to live animal models. Herein, we focus on various types of small molecule fluorescent probes for the detection and measurement of physical parameters of the microenvironment, including pH, polarity, viscosity, mechanical force, temperature, and electron potential. For each parameter, we primarily describe the chemical mechanisms underlying how physical properties are correlated with changes of various fluorescent signals. This review provides both an overview and a perspective for the development of small molecule fluorescent probes to visualize the dynamic changes in the cellular environment, to expand the knowledge for biological process, and to enrich diagnostic tools for human diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferroptosis: An Iron-Dependent Form of Nonapoptotic Cell Death
Dixon, S. J., Lemberg, K. M., Lamprecht, M. R., Skouta, R., Zaitsev, E. M., Gleason, C. E., Patel, D. N., Bauer, A. J., Cantley, A. M., Yang, W. S., et al. (2012) · Cell · doi:10.1016/j.cell.2012.03.042 · Cited by 18,691
Aggregation-induced emission of 1-methyl-1,2,3,4,5-pentaphenylsilole
Luo, J., Xie, Z., Lam, J. W. Y., Cheng, L., Tang, B. Z., Chen, H., Qiu, C., Kwok, H. S., Zhan, X., Liu, Y., et al. (2001) · Chemical Communications · doi:10.1039/b105159h · Cited by 8,358
Self-citationAggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Solvatochromic Dyes as Solvent Polarity Indicators
Reichardt, C. (1994) · Chemical Reviews · doi:10.1021/cr00032a005 · Cited by 5,527
Lipid rafts and signal transduction
Simons, K., & Toomre, D. (2000) · Nature Reviews Molecular Cell Biology · doi:10.1038/35036052 · Cited by 5,371
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Lipid rafts as a membrane-organizing principle
Lingwood, D., & Simons, K. (2010) · Science · doi:10.1126/science.1174621 · Cited by 4,417
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Ferroptosis: Death by Lipid Peroxidation
Yang, W. S., & Stockwell, B. R. (2016) · Trends in Cell Biology · doi:10.1016/j.tcb.2015.10.014 · Cited by 3,088
Fatty acid synthase and the lipogenic phenotype in cancer pathogenesis
Menendez, J. A., & Lupu, R. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2222 · Cited by 2,941
Physiological Roles of Mitochondrial Reactive Oxygen Species
Sena, L. A., & Chandel, N. S. (2012) · Molecular Cell · doi:10.1016/j.molcel.2012.09.025 · Cited by 2,632
Visualizing secretion and synaptic transmission with pH-sensitive green fluorescent proteins
Miesenböck, G., De Angelis, D. A., & Rothman, J. E. (1998) · Nature · doi:10.1038/28190 · Cited by 2,563
Nile red: a selective fluorescent stain for intracellular lipid droplets.
Greenspan, P., Mayer, E. P., & Fowler, S. D. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.3.965 · Cited by 2,543
Adapting Proteostasis for Disease Intervention
Balch, W. E., Morimoto, R. I., Dillin, A., & Kelly, J. W. (2008) · Science · doi:10.1126/science.1141448 · Cited by 2,495
Dysregulated pH: a perfect storm for cancer progression
Webb, B. A., Chimenti, M., Jacobson, M. P., & Barber, D. L. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3110 · Cited by 2,237
Sensors and regulators of intracellular pH
Casey, J. R., Grinstein, S., & Orlowski, J. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2820 · Cited by 2,218
Neutral red uptake assay for the estimation of cell viability/cytotoxicity
Repetto, G., del Peso, A., & Zurita, J. L. (2008) · Nature Protocols · doi:10.1038/nprot.2008.75 · Cited by 2,207
Ohkuma, S., & Poole, B. (1978) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.75.7.3327 · Cited by 2,174
A practical guide to single-molecule FRET
Roy, R., Hohng, S., & Ha, T. (2008) · Nature Methods · doi:10.1038/nmeth.1208 · Cited by 2,152
EMT and Dissemination Precede Pancreatic Tumor Formation
Rhim, A. D., Mirek, E. T., Aiello, N. M., Maitra, A., Bailey, J. M., McAllister, F., Reichert, M., Beatty, G. L., Rustgi, A. K., Vonderheide, R. H., et al. (2012) · Cell · doi:10.1016/j.cell.2011.11.025 · Cited by 2,136
Thomas, J. A., Buchsbaum, R. N., Zimniak, A., & Racker, E. (1979) · Biochemistry · doi:10.1021/bi00578a012 · Cited by 2,132
The mystery of membrane organization: composition, regulation and roles of lipid rafts
Sezgin, E., Levental, I., Mayor, S., & Eggeling, C. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.16 · Cited by 2,124
Free Radical Lipid Peroxidation: Mechanisms and Analysis
Yin, H., Xu, L., & Porter, N. A. (2011) · Chemical Reviews · doi:10.1021/cr200084z · Cited by 1,937
New sensing mechanisms for design of fluorescent chemosensors emerging in recent years
Wu, J., Liu, W., Ge, J., Zhang, H., & Wang, P. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00224k · Cited by 1,858
Recent advances in organic mechanofluorochromic materials
Chi, Z., Zhang, X., Xu, B., Zhou, X., Ma, C., Zhang, Y., Liu, S., & Xu, J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35016e · Cited by 1,787
Self-citationLuminescent probes and sensors for temperature
Wang, X.-D., Wolfbeis, O. S., & Meier, R. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60102a · Cited by 1,647
The proteostasis network and its decline in ageing
Hipp, M. S., Kasturi, P., & Hartl, F. U. (2019) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-019-0101-y · Cited by 1,642
The properties of organic liquids that are relevant to their use as solvating solvents
Marcus, Y. (1993) · Chemical Society Reviews · doi:10.1039/cs9932200409 · Cited by 1,631
Fluorescent Indicators for Intracellular pH
Han, J., & Burgess, K. (2010) · Chemical Reviews · doi:10.1021/cr900249z · Cited by 1,620
Excited-state intramolecular proton-transfer (ESIPT) based fluorescence sensors and imaging agents
Sedgwick, A. C., Wu, L., Han, H.-H., Bull, S. D., He, X.-P., James, T. D., Sessler, J. L., Tang, B. Z., Tian, H., & Yoon, J. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00185e · Cited by 1,569
Sapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503873 · Cited by 1,561
Unfolding the role of protein misfolding in neurodegenerative diseases
Soto, C. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1007 · Cited by 1,506
A general method to improve fluorophores for live-cell and single-molecule microscopy
Grimm, J. B., English, B. P., Chen, J., Slaughter, J. P., Zhang, Z., Revyakin, A., Patel, R., Macklin, J. J., Normanno, D., Singer, R. H., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3256 · Cited by 1,501
Santos, C. R., & Schulze, A. (2012) · The FEBS Journal · doi:10.1111/j.1742-4658.2012.08644.x · Cited by 1,335
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Fluorometric determination of amyloid fibrils in vitro using the fluorescent dye, thioflavine T
Naiki, H., Higuchi, K., Hosokawa, M., & Takeda, T. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90046-8 · Cited by 1,223
Klymchenko, A. S. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00517 · Cited by 1,220
Okabe, K., Inada, N., Gota, C., Harada, Y., Funatsu, T., & Uchiyama, S. (2012) · Nature Communications · doi:10.1038/ncomms1714 · Cited by 1,203
Absorption and fluorescence properties of fluorescein
Sjöback, R., Nygren, J., & Kubista, M. (1995) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/0584-8539(95)01421-p · Cited by 1,069
Platt, F. M., d’Azzo, A., Davidson, B. L., Neufeld, E. F., & Tifft, C. J. (2018) · Nature Reviews Disease Primers · doi:10.1038/s41572-018-0025-4 · Cited by 1,052
Reers, M., Smith, T. W., & Chen, L. B. (1991) · Biochemistry · doi:10.1021/bi00232a015 · Cited by 1,047
Cytoplasmic pH and free Mg2+ in lymphocytes.
Rink, T. J., Tsien, R. Y., & Pozzan, T. (1982) · The Journal of cell biology · doi:10.1083/jcb.95.1.189 · Cited by 1,044
Förster resonance energy transfer (FRET)-based small-molecule sensors and imaging agents
Wu, L., Huang, C., Emery, B. P., Sedgwick, A. C., Bull, S. D., He, X.-P., Tian, H., Yoon, J., Sessler, J. L., & James, T. D. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00318e · Cited by 1,026
FRET-Based Small-Molecule Fluorescent Probes: Rational Design and Bioimaging Applications
Yuan, L., Lin, W., Zheng, K., & Zhu, S. (2013) · Accounts of Chemical Research · doi:10.1021/ar300273v · Cited by 1,021
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Molecular Rotor Measures Viscosity of Live Cells via Fluorescence Lifetime Imaging
Kuimova, M. K., Yahioglu, G., Levitt, J. A., & Suhling, K. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800570d · Cited by 815
Selective molecular imaging of viable cancer cells with pH-activatable fluorescence probes
Urano, Y., Asanuma, D., Hama, Y., Koyama, Y., Barrett, T., Kamiya, M., Nagano, T., Watanabe, T., Hasegawa, A., Choyke, P. L., et al. (2009) · Nature Medicine · doi:10.1038/nm.1854 · Cited by 801
Appreciating force and shape—the rise of mechanotransduction in cell biology
Iskratsch, T., Wolfenson, H., & Sheetz, M. P. (2014) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3903 · Cited by 798
A Photostable AIE Luminogen for Specific Mitochondrial Imaging and Tracking
Leung, C. W. T., Hong, Y., Chen, S., Zhao, E., Lam, J. W. Y., & Tang, B. Z. (2013) · Journal of the American Chemical Society · doi:10.1021/ja310324q · Cited by 729
Wang, C., Chi, W., Qiao, Q., Tan, D., Xu, Z., & Liu, X. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00239b · Cited by 710
Resistance to cancer chemotherapy: failure in drug response from ADME to P-gp
Alfarouk, K. O., Stock, C.-M., Taylor, S., Walsh, M., Muddathir, A. K., Verduzco, D., Bashir, A. H. H., Mohammed, O. Y., Elhassan, G. O., Harguindey, S., et al. (2015) · Cancer Cell International · doi:10.1186/s12935-015-0221-1 · Cited by 665
Laurdan and Prodan as Polarity-Sensitive Fluorescent Membrane Probes
Parasassi, T., Krasnowska, E. K., Bagatolli, L., & Gratton, E. (1998) · Journal of Fluorescence · doi:10.1023/a:1020528716621 · Cited by 659
Imaging intracellular viscosity of a single cell during photoinduced cell death
Kuimova, M. K., Botchway, S. W., Parker, A. W., Balaz, M., Collins, H. A., Anderson, H. L., Suhling, K., & Ogilby, P. R. (2009) · Nature Chemistry · doi:10.1038/nchem.120 · Cited by 639
Pratap, R., & Ram, V. J. (2014) · Chemical Reviews · doi:10.1021/cr500075s · Cited by 604
Nile red as a polarity-sensitive fluorescent probe of hydrophobic protein surfaces
Sackett, D. L., & Wolff, J. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90157-6 · Cited by 591
Use the force: membrane tension as an organizer of cell shape and motility
Diz-Muñoz, A., Fletcher, D. A., & Weiner, O. D. (2013) · Trends in Cell Biology · doi:10.1016/j.tcb.2012.09.006 · Cited by 574
Zhou, K., Wang, Y., Huang, X., Luby‐Phelps, K., Sumer, B. D., & Gao, J. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201100884 · Cited by 573
A fluorescent membrane tension probe
Colom, A., Derivery, E., Soleimanpour, S., Tomba, C., Molin, M. D., Sakai, N., González-Gaitán, M., Matile, S., & Roux, A. (2018) · Nature Chemistry · doi:10.1038/s41557-018-0127-3 · Cited by 572
Fluorescence imaging of pathophysiological microenvironments
Wang, S., Ren, W. X., Hou, J.-T., Won, M., An, J., Chen, X., Shu, J., & Kim, J. S. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00083g · Cited by 568
The Coming Decade of Cell Death Research: Five Riddles
Green, D. R. (2019) · Cell · doi:10.1016/j.cell.2019.04.024 · Cited by 566
Fluorescent bioimaging of pH: from design to applications
Hou, J.-T., Ren, W. X., Li, K., Seo, J., Sharma, A., Yu, X.-Q., & Kim, J. S. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00719h · Cited by 557
Kong, B., Zhu, A., Ding, C., Zhao, X., Li, B., & Tian, Y. (2012) · Advanced Materials · doi:10.1002/adma.201202599 · Cited by 556
Ehrenberg, B., Montana, V., Wei, M. D., Wuskell, J. P., & Loew, L. M. (1988) · Biophysical Journal · doi:10.1016/s0006-3495(88)83158-8 · Cited by 524
Hydrophilic Fluorescent Nanogel Thermometer for Intracellular Thermometry
Gota, C., Okabe, K., Funatsu, T., Harada, Y., & Uchiyama, S. (2009) · Journal of the American Chemical Society · doi:10.1021/ja807714j · Cited by 524
Anti-quenching NIR-II molecular fluorophores for in vivo high-contrast imaging and pH sensing
Wang, S., Fan, Y., Li, D., Sun, C., Lei, Z., Lu, L., Wang, T., & Zhang, F. (2019) · Nature Communications · doi:10.1038/s41467-019-09043-x · Cited by 510
Small-Molecule Fluorescent Probes for Live-Cell Super-Resolution Microscopy
Wang, L., Frei, M. S., Salim, A., & Johnsson, K. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11134 · Cited by 504
Mapping viscosity in cells using molecular rotors
Kuimova, M. K. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41674c · Cited by 484
Coumarin heterocyclic derivatives: chemical synthesis and biological activity
Medina, F. G., Marrero, J. G., Macías-Alonso, M., González, M. C., Córdova-Guerrero, I., Teissier García, A. G., & Osegueda-Robles, S. (2015) · Natural Product Reports · doi:10.1039/c4np00162a · Cited by 469
Shi, Z., Han, X., Hu, W., Bai, H., Peng, B., Ji, L., Fan, Q., Li, L., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00234h · Cited by 469
A Self-Calibrating Bipartite Viscosity Sensor for Mitochondria
Yang, Z., He, Y., Lee, J.-H., Park, N., Suh, M., Chae, W.-S., Cao, J., Peng, X., Jung, H., Kang, C., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403851p · Cited by 468
Shi, W., Li, X., & Ma, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201202533 · Cited by 468
Mitochondria-Immobilized pH-Sensitive Off–On Fluorescent Probe
Lee, M. H., Park, N., Yi, C., Han, J. H., Hong, J. H., Kim, K. P., Kang, D. H., Sessler, J. L., Kang, C., & Kim, J. S. (2014) · Journal of the American Chemical Society · doi:10.1021/ja506301n · Cited by 468
Activatable Rotor for Quantifying Lysosomal Viscosity in Living Cells
Wang, L., Xiao, Y., Tian, W., & Deng, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311688g · Cited by 464
van Meer, G. (1989) · Annual Review of Cell Biology · doi:10.1146/annurev.cb.05.110189.001335 · Cited by 464
Quantitative imaging of membrane lipid order in cells and organisms
Owen, D. M., Rentero, C., Magenau, A., Abu-Siniyeh, A., & Gaus, K. (2012) · Nature Protocols · doi:10.1038/nprot.2011.419 · Cited by 458
Chen, S., Hong, Y., Liu, Y., Liu, J., Leung, C. W. T., Li, M., Kwok, R. T. K., Zhao, E., Lam, J. W. Y., Yu, Y., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja400337p · Cited by 434
Self-citationPeng, X., Yang, Z., Wang, J., Fan, J., He, Y., Song, F., Wang, B., Sun, S., Qu, J., Qi, J., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1104014 · Cited by 431
Wan, Q., Chen, S., Shi, W., Li, L., & Ma, H. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201405742 · Cited by 420
Quantum Dot Nano Thermometers Reveal Heterogeneous Local Thermogenesis in Living Cells
Yang, J.-M., Yang, H., & Lin, L. (2011) · ACS Nano · doi:10.1021/nn201142f · Cited by 416
Spectral and photophysical studies of benzo[c]xanthene dyes: Dual emission pH sensors
Whitaker, J. E., Haugland, R. P., & Prendergast, F. G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90237-n · Cited by 397
Koide, Y., Urano, Y., Hanaoka, K., Terai, T., & Nagano, T. (2011) · ACS Chemical Biology · doi:10.1021/cb1002416 · Cited by 395
Spectra, membrane binding, and potentiometric responses of new charge shift probes
Fluhler, E., Burnham, V. G., & Loew, L. M. (1985) · Biochemistry · doi:10.1021/bi00342a010 · Cited by 387
Zhang, Z., Wu, Y.-S., Tang, K.-C., Chen, C.-L., Ho, J.-W., Su, J., Tian, H., & Chou, P.-T. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b03491 · Cited by 372
Activity-Based Sensing and Theranostic Probes Based on Photoinduced Electron Transfer
Sun, W., Li, M., Fan, J., & Peng, X. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00340 · Cited by 364
Wang, K., Liu, L., Mao, D., Xu, S., Tan, C., Cao, Q., Mao, Z., & Liu, B. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202104163 · Cited by 358
Kano, K., & Fendler, J. H. (1978) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(78)90048-2 · Cited by 353
Zhou, K., Liu, H., Zhang, S., Huang, X., Wang, Y., Huang, G., Sumer, B. D., & Gao, J. (2012) · Journal of the American Chemical Society · doi:10.1021/ja300176w · Cited by 344
BODIPY-Based Hydroxyaryl Derivatives as Fluorescent pH Probes
Baruah, M., Qin, W., Basarić, N., De Borggraeve, W. M., & Boens, N. (2005) · The Journal of Organic Chemistry · doi:10.1021/jo0503714 · Cited by 343
Quantum Dot–Fluorescent Protein FRET Probes for Sensing Intracellular pH
Dennis, A. M., Rhee, W. J., Sotto, D., Dublin, S. N., & Bao, G. (2012) · ACS Nano · doi:10.1021/nn2038077 · Cited by 340
Recent advances in multifunctional fluorescent probes for viscosity and analytes
Yang, X., Zhang, D., Ye, Y., & Zhao, Y. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214336 · Cited by 340
Cyanine fluorophore derivatives with enhanced photostability
Altman, R. B., Terry, D. S., Zhou, Z., Zheng, Q., Geggier, P., Kolster, R. A., Zhao, Y., Javitch, J. A., Warren, J. D., & Blanchard, S. C. (2012) · Nature Methods · doi:10.1038/nmeth.1774 · Cited by 339
Fluorescent Biomembrane Probe for Ratiometric Detection of Apoptosis
Shynkar, V. V., Klymchenko, A. S., Kunzelmann, C., Duportail, G., Muller, C. D., Demchenko, A. P., Freyssinet, J.-M., & Mely, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068008h · Cited by 335
Kim, H. J., Heo, C. H., & Kim, H. M. (2013) · Journal of the American Chemical Society · doi:10.1021/ja409971k · Cited by 333
Li, H., Shi, W., Li, X., Hu, Y., Fang, Y., & Ma, H. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b09722 · Cited by 333
Water-soluble perylenediimides: design concepts and biological applications
Sun, M., Müllen, K., & Yin, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00754b · Cited by 332
A novel mechanism for red emission carbon dots: hydrogen bond dominated molecular states emission
Zhang, T., Zhu, J., Zhai, Y., Wang, H., Bai, X., Dong, B., Wang, H., & Song, H. (2017) · Nanoscale · doi:10.1039/c7nr03570e · Cited by 332
The Impact of Systemic Inflammation on Neurodevelopment
Jiang, N. M., Cowan, M., Moonah, S. N., & Petri, W. A. (2018) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2018.06.008 · Cited by 328
Optically monitoring voltage in neurons by photo-induced electron transfer through molecular wires
Miller, E. W., Lin, J. Y., Frady, E. P., Steinbach, P. A., Kristan, W. B., & Tsien, R. Y. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1120694109 · Cited by 323
Pyridinium N-Phenolate Betaine Dyes
Machado, V. G., Stock, R. I., & Reichardt, C. (2014) · Chemical Reviews · doi:10.1021/cr5001157 · Cited by 313
Fundamentals in the chemistry of cyanine dyes: A review
Shindy, H. A. (2017) · Dyes and Pigments · doi:10.1016/j.dyepig.2017.06.029 · Cited by 309
Synthesis of Fluorinated Fluoresceins
Sun, W.-C., Gee, K. R., Klaubert, D. H., & Haugland, R. P. (1997) · The Journal of Organic Chemistry · doi:10.1021/jo9706178 · Cited by 299
Danylchuk, D. I., Jouard, P.-H., & Klymchenko, A. S. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c10972 · Cited by 298
Ultra-pH-Sensitive Nanoprobe Library with Broad pH Tunability and Fluorescence Emissions
Ma, X., Wang, Y., Zhao, T., Li, Y., Su, L.-C., Wang, Z., Huang, G., Sumer, B. D., & Gao, J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja5053158 · Cited by 292
Tyrosine-Selective Protein Alkylation Using π-Allylpalladium Complexes
Tilley, S. D., & Francis, M. B. (2006) · Journal of the American Chemical Society · doi:10.1021/ja057106k · Cited by 287
Myochin, T., Kiyose, K., Hanaoka, K., Kojima, H., Terai, T., & Nagano, T. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1063058 · Cited by 284
Fluorogenic Probes for Multicolor Imaging in Living Cells
Lukinavičius, G., Reymond, L., Umezawa, K., Sallin, O., D’Este, E., Göttfert, F., Ta, H., Hell, S. W., Urano, Y., & Johnsson, K. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b04782 · Cited by 281
π-Expanded coumarins: synthesis, optical properties and applications
Tasior, M., Kim, D., Singha, S., Krzeszewski, M., Ahn, K. H., & Gryko, D. T. (2015) · Journal of Materials Chemistry C · doi:10.1039/c4tc02665a · Cited by 275
Nile Red and Nile Blue: Applications and Syntheses of Structural Analogues
Martinez, V., & Henary, M. (2016) · Chemistry – A European Journal · doi:10.1002/chem.201601570 · Cited by 275
Fluorescent Molecular Rotors for Viscosity Sensors
Lee, S., Heo, J., Woo, H. C., Lee, J., Seo, Y. H., Lee, C., Kim, S., & Kwon, O. (2018) · Chemistry – A European Journal · doi:10.1002/chem.201801389 · Cited by 271
Recent advances in the application of BODIPY in bioimaging and chemosensing
Kaur, P., & Singh, K. (2019) · Journal of Materials Chemistry C · doi:10.1039/c9tc03719e · Cited by 268
Polarity-Sensitive Coumarins Tailored to Live Cell Imaging
Signore, G., Nifosì, R., Albertazzi, L., Storti, B., & Bizzarri, R. (2010) · Journal of the American Chemical Society · doi:10.1021/ja9050444 · Cited by 264
Ren, M., Deng, B., Zhou, K., Kong, X., Wang, J.-Y., & Lin, W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04385 · Cited by 261
Jiang, N., Fan, J., Xu, F., Peng, X., Mu, H., Wang, J., & Xiong, X. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410645 · Cited by 258
Fluorene Analogues of Prodan with Superior Fluorescence Brightness and Solvatochromism
Kucherak, O. A., Didier, P., Mély, Y., & Klymchenko, A. S. (2010) · The Journal of Physical Chemistry Letters · doi:10.1021/jz9003685 · Cited by 257
Ma, T., Hou, Y., Zeng, J., Liu, C., Zhang, P., Jing, L., Shangguan, D., & Gao, M. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b08900 · Cited by 254
Dong, B., Song, X., Wang, C., Kong, X., Tang, Y., & Lin, W. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00422 · Cited by 253
Two‐Color Probe to Monitor a Wide Range of pH Values in Cells
Lee, M. H., Han, J. H., Lee, J. H., Park, N., Kumar, R., Kang, C., & Kim, J. S. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301894 · Cited by 252
Li, Y., Wang, Y., Yang, S., Zhao, Y., Yuan, L., Zheng, J., & Yang, R. (2015) · Analytical Chemistry · doi:10.1021/ac5045498 · Cited by 251
Micro/Nanoscale Thermometry for Cellular Thermal Sensing
Bai, T., & Gu, N. (2016) · Small · doi:10.1002/smll.201600665 · Cited by 251
Zhang, Y., Li, Z., Hu, W., & Liu, Z. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02678 · Cited by 243
Characterization and Application of a New Optical Probe for Membrane Lipid Domains
Jin, L., Millard, A. C., Wuskell, J. P., Dong, X., Wu, D., Clark, H. A., & Loew, L. M. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.072884 · Cited by 234
Solvent polarity scales: determination of new ET(30) values for 84 organic solvents
Cerón‐Carrasco, J. P., Jacquemin, D., Laurence, C., Planchat, A., Reichardt, C., & Sraïdi, K. (2014) · Journal of Physical Organic Chemistry · doi:10.1002/poc.3293 · Cited by 231
A minireview of viscosity-sensitive fluorescent probes: design and biological applications
Ma, C., Sun, W. C., Xu, L., Qian, Y., Dai, J., Zhong, G., Hou, Y., Liu, J., & Shen, B. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb01146k · Cited by 227
A Photostable Silicon Rhodamine Platform for Optical Voltage Sensing
Huang, Y.-L., Walker, A. S., & Miller, E. W. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b06644 · Cited by 222
Goujon, A., Colom, A., Straková, K., Mercier, V., Mahecic, D., Manley, S., Sakai, N., Roux, A., & Matile, S. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b13189 · Cited by 222
Yang, S.-L., Li, G., Guo, M.-Y., Liu, W.-S., Bu, R., & Gao, E.-Q. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c03432 · Cited by 220
Overly, C. C., Lee, K. D., Berthiaume, E., & Hollenbeck, P. J. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.8.3156 · Cited by 217
Kumar, R., Han, J., Lim, H.-J., Ren, W. X., Lim, J.-Y., Kim, J.-H., & Kim, J. S. (2014) · Journal of the American Chemical Society · doi:10.1021/ja510421q · Cited by 214
Mitochondria-targeted fluorescent thermometer monitors intracellular temperature gradient
Arai, S., Suzuki, M., Park, S.-J., Yoo, J. S., Wang, L., Kang, N.-Y., Ha, H.-H., & Chang, Y.-T. (2015) · Chemical Communications · doi:10.1039/c5cc01088h · Cited by 213
Diwu, Z., Chen, C.-S., Zhang, C., Klaubert, D. H., & Haugland, R. P. (1999) · Chemistry & Biology · doi:10.1016/s1074-5521(99)80059-3 · Cited by 212
How do cells respond to their thermal environment?
Lepock, J. R. (2005) · International Journal of Hyperthermia · doi:10.1080/02656730500307298 · Cited by 212
Yamaguchi, E., Wang, C., Fukazawa, A., Taki, M., Sato, Y., Sasaki, T., Ueda, M., Sasaki, N., Higashiyama, T., & Yamaguchi, S. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201500229 · Cited by 209
Multi-dimensional super-resolution imaging enables surface hydrophobicity mapping
Bongiovanni, M. N., Godet, J., Horrocks, M. H., Tosatto, L., Carr, A. R., Wirthensohn, D. C., Ranasinghe, R. T., Lee, J.-E., Ponjavic, A., Fritz, J. V., et al. (2016) · Nature Communications · doi:10.1038/ncomms13544 · Cited by 209
Chromophore Transformations in Red Fluorescent Proteins
Subach, F. V., & Verkhusha, V. V. (2012) · Chemical Reviews · doi:10.1021/cr2001965 · Cited by 208
A General Strategy to Control Viscosity Sensitivity of Molecular Rotor‐Based Fluorophores
Ye, S., Zhang, H., Fei, J., Wolstenholme, C. H., & Zhang, X. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202011108 · Cited by 207
Self-citationA Ratiometric pH Reporter For Imaging Protein-dye Conjugates In Living Cells
Han, J., Loudet, A., Barhoumi, R., Burghardt, R. C., & Burgess, K. (2009) · Journal of the American Chemical Society · doi:10.1021/ja8073374 · Cited by 204
Bains, G. K., Kim, S. H., Sorin, E. J., & Narayanaswami, V. (2012) · Biochemistry · doi:10.1021/bi3005285 · Cited by 202
Deng, Y., & Feng, G. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03199 · Cited by 202
Near-Infrared Sensing Properties of Dimethlyamino-Substituted BF2−Azadipyrromethenes
McDonnell, S. O., & O'Shea, D. F. (2006) · Organic Letters · doi:10.1021/ol061171x · Cited by 201
A review: the trend of progress about pH probes in cell application in recent years
Yue, Y., Huo, F., Lee, S., Yin, C., & Yoon, J. (2017) · The Analyst · doi:10.1039/c6an01942k · Cited by 200
Li, K., Liu, Y., Li, Y., Feng, Q., Hou, H., & Tang, B. Z. (2017) · Chemical Science · doi:10.1039/c7sc03076b · Cited by 199
Self-citationDanylchuk, D. I., Moon, S., Xu, K., & Klymchenko, A. S. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201907690 · Cited by 199
Lysosome triggered near-infrared fluorescence imaging of cellular trafficking processes in real time
Grossi, M., Morgunova, M., Cheung, S., Scholz, D., Conroy, E., Terrile, M., Panarella, A., Simpson, J. C., Gallagher, W. M., & O’Shea, D. F. (2016) · Nature Communications · doi:10.1038/ncomms10855 · Cited by 197
Ke, G., Wang, C., Ge, Y., Zheng, N., Zhu, Z., & Yang, C. J. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3082439 · Cited by 196
Improved indicators of cell membrane potential that use fluorescence resonance energy transfer
González, J. E., & Tsien, R. Y. (1997) · Chemistry & Biology · doi:10.1016/s1074-5521(97)90070-3 · Cited by 195
A Molecular Fluorescent Probe for Targeted Visualization of Temperature at the Endoplasmic Reticulum
Arai, S., Lee, S.-C., Zhai, D., Suzuki, M., & Chang, Y. T. (2014) · Scientific Reports · doi:10.1038/srep06701 · Cited by 191
Jokic, T., Borisov, S. M., Saf, R., Nielsen, D. A., Kühl, M., & Klimant, I. (2012) · Analytical Chemistry · doi:10.1021/ac3011796 · Cited by 190
Yin, J., Peng, M., & Lin, W. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01293 · Cited by 189
Probing DNA sequences in solution with a monomer-excimer fluorescence color change
Paris, P. L., Langenhan, J. M., & Kool, E. T. (1998) · Nucleic Acids Research · doi:10.1093/nar/26.16.3789 · Cited by 186
Kinetic behaviour of calf-intestinal alkaline phosphatase with 4-methylumbelliferyl phosphate
Fernley, H. N., & Walker, P. G. (1965) · Biochemical Journal · doi:10.1042/bj0970095 · Cited by 185
Ratiometric detection of pH fluctuation in mitochondria with a new fluorescein/cyanine hybrid sensor
Chen, Y., Zhu, C., Cen, J., Bai, Y., He, W., & Guo, Z. (2015) · Chemical Science · doi:10.1039/c4sc04021j · Cited by 185
Strakova, K., Assies, L., Goujon, A., Piazzolla, F., Humeniuk, H. V., & Matile, S. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00279 · Cited by 184
DAVILA, H. V., SALZBERG, B. M., COHEN, L. B., & WAGGONER, A. S. (1973) · Nature New Biology · doi:10.1038/newbio241159a0 · Cited by 183
Niko, Y., Didier, P., Mely, Y., Konishi, G.-I., & Klymchenko, A. S. (2016) · Scientific Reports · doi:10.1038/srep18870 · Cited by 183
Green fluorescent protein based pH indicators for in vivo use: a review
Bizzarri, R., Serresi, M., Luin, S., & Beltram, F. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2515-9 · Cited by 181
Li, X., Hu, Y., Li, X., & Ma, H. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02782 · Cited by 175
Mitochondria-targeted ratiometric fluorescent probe for real time monitoring of pH in living cells
Wu, M.-Y., Li, K., Liu, Y.-H., Yu, K.-K., Xie, Y.-M., Zhou, X.-D., & Yu, X.-Q. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.113 · Cited by 174
Self-citationLi, S., Wang, P., Feng, W., Xiang, Y., Dou, K., & Liu, Z. (2020) · Chemical Communications · doi:10.1039/c9cc08267k · Cited by 172
A TICT based NIR-fluorescent probe for human serum albumin: a pre-clinical diagnosis in blood serum
Reja, S. I., Khan, I. A., Bhalla, V., & Kumar, M. (2016) · Chemical Communications · doi:10.1039/c5cc08217j · Cited by 171
Small Molecular Fluorescent Probes for Imaging of Viscosity in Living Biosystems
Xiao, H., Li, P., & Tang, B. (2021) · Chemistry – A European Journal · doi:10.1002/chem.202004888 · Cited by 171
Palette of fluorinated voltage-sensitive hemicyanine dyes
Yan, P., Acker, C. D., Zhou, W.-L., Lee, P., Bollensdorff, C., Negrean, A., Lotti, J., Sacconi, L., Antic, S. D., Kohl, P., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1214850109 · Cited by 170
Li, K., Feng, Q., Niu, G., Zhang, W., Li, Y., Kang, M., Xu, K., He, J., Hou, H., & Tang, B. Z. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00820 · Cited by 168
Liu, X., Su, Y., Tian, H., Yang, L., Zhang, H., Song, X., & Foley, J. W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00754 · Cited by 167
Organic dye assemblies with aggregation‐induced photophysical changes and their bio‐applications
Ji, C., Lai, L., Li, P., Wu, Z., Cheng, W., & Yin, M. (2021) · Aggregate · doi:10.1002/agt2.39 · Cited by 163
Khare, S. D., Caplow, M., & Dokholyan, N. V. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406650101 · Cited by 161
Synthesis and Photophysical Investigation of a Series of Push–Pull Arylvinyldiazine Chromophores
Achelle, S., Barsella, A., Baudequin, C., Caro, B., & Robin-le Guen, F. (2012) · The Journal of Organic Chemistry · doi:10.1021/jo3004919 · Cited by 161
Cao, C., Liu, X., Qiao, Q., Zhao, M., Yin, W., Mao, D., Zhang, H., & Xu, Z. (2014) · Chemical Communications · doi:10.1039/c4cc08010f · Cited by 160
pH-Responsive fluorescent graphene quantum dots for fluorescence-guided cancer surgery and diagnosis
Fan, Z., Zhou, S., Garcia, C., Fan, L., & Zhou, J. (2017) · Nanoscale · doi:10.1039/c7nr00888k · Cited by 160
Tang, L., Jin, J. K., Qin, A., Yuan, W. Z., Mao, Y., Mei, J., Sun, J. Z., & Tang, B. Z. (2009) · Chemical Communications · doi:10.1039/b907382e · Cited by 158
Wolstenholme, C. H., Hu, H., Ye, S., Funk, B. E., Jain, D., Hsiung, C.-H., Ning, G., Liu, Y., Li, X., & Zhang, X. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07245 · Cited by 158
Self-citationTakahashi, S., Kagami, Y., Hanaoka, K., Terai, T., Komatsu, T., Ueno, T., Uchiyama, M., Koyama‐Honda, I., Mizushima, N., Taguchi, T., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b00277 · Cited by 155
Zhao, N., Chen, S., Hong, Y., & Tang, B. Z. (2015) · Chemical Communications · doi:10.1039/c5cc04731e · Cited by 154
An Efficient Fluorescent Probe for Ratiometric pH Measurements in Aqueous Solutions
Charier, S., Ruel, O., Baudin, J., Alcor, D., Allemand, J., Meglio, A., & Jullien, L. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200460557 · Cited by 153
Improved Photostability and Fluorescence Properties through Polyfluorination of a Cyanine Dye
Renikuntla, B. R., Rose, H. C., Eldo, J., Waggoner, A. S., & Armitage, B. A. (2004) · Organic Letters · doi:10.1021/ol036081w · Cited by 152
Probing Polarity and Heterogeneity of Lipid Droplets in Live Cells Using a Push–Pull Fluorophore
Collot, M., Bou, S., Fam, K. T., Richert, L., Mély, Y., Danglot, L., & Klymchenko, A. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04218 · Cited by 152
Two-Photon Fluorescent Probe for Monitoring Autophagy via Fluorescence Lifetime Imaging
Hou, L., Ning, P., Feng, Y., Ding, Y., Bai, L., Li, L., Yu, H., & Meng, X. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01631 · Cited by 151
Development of pH-Responsive Fluorescent False Neurotransmitters
Lee, M., Gubernator, N. G., Sulzer, D., & Sameš, D. (2010) · Journal of the American Chemical Society · doi:10.1021/ja101740k · Cited by 150
Niu, G., Zhang, P., Liu, W., Wang, M., Zhang, H., Wu, J., Zhang, L., & Wang, P. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04417 · Cited by 150
Coumarin-based near-infrared fluorogenic probes: Recent advances, challenges and future perspectives
Fan, Y., Wu, Y., Hou, J., Wang, P., Peng, X., & Ge, G. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215020 · Cited by 150
Homma, M., Takei, Y., Murata, A., Inoue, T., & Takeoka, S. (2015) · Chemical Communications · doi:10.1039/c4cc10349a · Cited by 146
Quinoline-Based Fluorescent Probe for Ratiometric Detection of Lysosomal pH
Li, G., Zhu, D., Xue, L., & Jiang, H. (2013) · Organic Letters · doi:10.1021/ol4023547 · Cited by 146
Liu, X., Chi, W., Qiao, Q., Kokate, S. V., Cabrera, E. P., Xu, Z., Liu, X., & Chang, Y. (2020) · ACS Sensors · doi:10.1021/acssensors.9b01951 · Cited by 145
Song, Y. Y., Zhang, H., Wang, X., Geng, X., Sun, Y., Liu, J., & Li, Z. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04644 · Cited by 145
Spectroscopic characterization of diverse amyloid fibrils in vitro by the fluorescent dyeNile red
Mishra, R., Sjölander, D., & Hammarström, P. (2011) · Molecular BioSystems · doi:10.1039/c0mb00236d · Cited by 144
Fluorescence imaging using synthetic GFP chromophores
Walker, C. L., Lukyanov, K. A., Yampolsky, I. V., Mishin, A. S., Bommarius, A. S., Duraj‐Thatte, A., Azizi, B., Tolbert, L. M., & Solntsev, K. M. (2015) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2015.06.002 · Cited by 144
Ashoka, A. H., Ashokkumar, P., Kovtun, Y. P., & Klymchenko, A. S. (2019) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.9b00668 · Cited by 144
Dong, B., Song, W., Lu, Y., Sun, Y., & Lin, W. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02015 · Cited by 137
A synergistic strategy to develop photostable and bright dyes with long Stokes shift for nanoscopy
Jiang, G., Ren, T., D’Este, E., Xiong, M., Xiong, B., Johnsson, K., Zhang, X., Wang, L., & Yuan, L. (2022) · Nature Communications · doi:10.1038/s41467-022-29547-3 · Cited by 137
Self-citationSahoo, D., Narayanaswami, V., Kay, C. M., & Ryan, R. O. (2000) · Biochemistry · doi:10.1021/bi992609m · Cited by 129
2'-Pyrene modified oligonucleotide provides a highly sensitive fluorescent probe of RNA
Yamana, K., Iwase, R., Furutani, S., Tsuchida, H., Zako, H., Yamaoka, T., & Murakami, A. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.11.2387 · Cited by 128
Song, H., Zhang, W., Zhang, Y., Yin, C., & Huo, F. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.136448 · Cited by 127
Dou, K., Huang, W., Xiang, Y., Li, S., & Liu, Z. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00634 · Cited by 126
Aggregation-Induced Fluorescence Probe for Monitoring Membrane Potential Changes in Mitochondria
Li, J., Kwon, N., Jeong, Y., Lee, S., Kim, G., & Yoon, J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b14548 · Cited by 125
Dziuba, D., Jurkiewicz, P., Cebecauer, M., Hof, M., & Hocek, M. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201507922 · Cited by 124
A ratiometric two-photon probe for quantitative imaging of mitochondrial pH values
Sarkar, A. R., Heo, C. H., Xu, L., Lee, H. W., Si, H. Y., Byun, J. W., & Kim, H. M. (2015) · Chemical Science · doi:10.1039/c5sc03708e · Cited by 123
Hu, X., Li, Y., Liu, T., Zhang, G., & Liu, S. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b04025 · Cited by 123
Guo, B., Jing, J., Nie, L., Xin, F., Gao, C., Yang, W. J., & Zhang, X. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb02615c · Cited by 121
Self-citationProtease-Activated Ratiometric Fluorescent Probe for pH Mapping of Malignant Tumors
Hou, Y., Zhou, J., Gao, Z., Sun, X., Liu, C., Shangguan, D., Yang, W., & Gao, M. (2015) · ACS Nano · doi:10.1021/acsnano.5b00276 · Cited by 119
Metadata
- Authors
- Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2024-02-14
- Volume
- 124
- Issue
- 4
- Pages
- 1738-1861
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W4391824438
- Cited by
- 408
- References
- 390
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.