The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Perfused multiwell plate for 3D liver tissue engineering
Open accessAbstract
In vitro models that capture the complexity of in vivo tissue and organ behaviors in a scalable and easy-to-use format are desirable for drug discovery. To address this, we have developed a bioreactor that fosters maintenance of 3D tissue cultures under constant perfusion and we have integrated multiple bioreactors into an array in a multiwell plate format. All bioreactors are fluidically isolated from each other. Each bioreactor in the array contains a scaffold that supports formation of hundreds of 3D microscale tissue units. The tissue units are perfused with cell culture medium circulated within the bioreactor by integrated pneumatic diaphragm micropumps. Electronic controls for the pumps are kept outside the incubator and connected to the perfused multiwell by pneumatic lines. The docking design and open-well bioreactor layout make handling perfused multiwell plates similar to using standard multiwell tissue culture plates. A model of oxygen consumption and transport in the circulating culture medium was used to predict appropriate operating parameters for primary liver cultures. Oxygen concentrations at key locations in the system were then measured as a function of flow rate and time after initiation of culture to determine oxygen consumption rates. After seven days of culture, tissue formed from cells seeded in the perfused multiwell reactor remained functionally viable as assessed by immunostaining for hepatocyte and liver sinusoidal endothelial cell (LSEC) phenotypic markers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hewitt, N. J., Gómez Lechón, M. J., Houston, J. B., Hallifax, D., Brown, H. S., Maurel, P., Kenna, J. G., Gustavsson, L., Lohmann, C., Skonberg, C., et al. (2007) · Drug Metabolism Reviews · doi:10.1080/03602530601093489 · Cited by 735
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Engineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
Self-citationA practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Oxygen: Modulator of metabolic zonation and disease of the liver
Jungermann, K., & Kietzmann, T. (2000) · Hepatology · doi:10.1002/hep.510310201 · Cited by 443
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Sin, A., Chin, K. C., Jamil, M. F., Kostov, Y., Rao, G., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp034077d · Cited by 368
Formation of steady‐state oxygen gradients in vitro: Application to liver zonation
Allen, J. W., & Bhatia, S. N. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10569 · Cited by 269
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Overcoming the challenges in administering biopharmaceuticals: Formulation and delivery strategies
Mitragotri, S., Burke, P. A., & Langer, R. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4363 · Cited by 1,702
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Three-Dimensional Cell Cultures in Drug Discovery and Development
Fang, Y., & Eglen, R. M. (2017) · SLAS Discovery · doi:10.1177/1087057117696795 · Cited by 849
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Self-citationEngineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476
In vitro models for liver toxicity testing
Soldatow, V. Y., LeCluyse, E. L., Griffith, L. G., & Rusyn, I. (2013) · Toxicol. Res. · doi:10.1039/c2tx20051a · Cited by 472
Self-citationMenstruation: science and society
Critchley, H. O. D., Babayev, E., Bulun, S. E., Clark, S., Garcia-Grau, I., Gregersen, P. K., Kilcoyne, A., Kim, J.-Y. J., Lavender, M., Marsh, E. E., et al. (2020) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.06.004 · Cited by 448
Self-citationOrgan-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Ma, X., Liu, J., Zhu, W., Tang, M., Lawrence, N., Yu, C., Gou, M., & Chen, S. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.011 · Cited by 401
Reconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis
Frey, O., Misun, P. M., Fluri, D. A., Hengstler, J. G., & Hierlemann, A. (2014) · Nature Communications · doi:10.1038/ncomms5250 · Cited by 387
Organotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Bavli, D., Prill, S., Ezra, E., Levy, G., Cohen, M., Vinken, M., Vanfleteren, J., Jaeger, M., & Nahmias, Y. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522556113 · Cited by 362
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Human pluripotent stem cell-derived neural constructs for predicting neural toxicity
Schwartz, M. P., Hou, Z., Propson, N. E., Zhang, J., Engstrom, C. J., Costa, V. S., Jiang, P., Nguyen, B. K., Bolin, J. M., Daly, W., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1516645112 · Cited by 325
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Organs-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Cell and tissue engineering for liver disease
Bhatia, S. N., Underhill, G. H., Zaret, K. S., & Fox, I. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3005975 · Cited by 309
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
3D Bioprinting of Tissue/Organ Models
Pati, F., Gantelius, J., & Svahn, H. A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201505062 · Cited by 301
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Campbell, S. B., Wu, Q., Yazbeck, J., Liu, C., Okhovatian, S., & Radisic, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00640 · Cited by 297
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
A microfluidically perfused three dimensional human liver model
Rennert, K., Steinborn, S., Gröger, M., Ungerböck, B., Jank, A.-M., Ehgartner, J., Nietzsche, S., Dinger, J., Kiehntopf, M., Funke, H., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.043 · Cited by 255
The relevance and potential roles of microphysiological systems in biology and medicine
Wikswo, J. P. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214542068 · Cited by 248
Tumor-on-a-chip: from bioinspired design to biomedical application
Liu, X., Fang, J., Huang, S., Wu, X., Xie, X., Wang, J., Liu, F., Zhang, M., Peng, Z., & Hu, N. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00277-8 · Cited by 246
Lauschke, V. M., Hendriks, D. F. G., Bell, C. C., Andersson, T. B., & Ingelman-Sundberg, M. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00150 · Cited by 241
3D microfluidic liver cultures as a physiological preclinical tool for hepatitis B virus infection
Ortega-Prieto, A. M., Skelton, J. K., Wai, S. N., Large, E., Lussignol, M., Vizcay-Barrena, G., Hughes, D., Fleck, R. A., Thursz, M., Catanese, M. T., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02969-8 · Cited by 236
Tsamandouras, N., Chen, W. L. K., Edington, C. D., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0122-4 · Cited by 222
Self-citationYoon No, D., Lee, K.-H., Lee, J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c5lc00611b · Cited by 205
Competency of different cell models to predict human hepatotoxic drugs
Gómez-Lechón, M. J., Tolosa, L., Conde, I., & Donato, M. T. (2014) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425255.2014.967680 · Cited by 199
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Microfluidic 3D models of cancer
Sung, K. E., & Beebe, D. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.002 · Cited by 190
Baker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188
Satoh, T., Sugiura, S., Shin, K., Onuki-Nagasaki, R., Ishida, S., Kikuchi, K., Kakiki, M., & Kanamori, T. (2018) · Lab on a Chip · doi:10.1039/c7lc00952f · Cited by 181
Prantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
High-throughput organ-on-a-chip systems: Current status and remaining challenges
Probst, C., Schneider, S., & Loskill, P. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.02.004 · Cited by 171
Biomimetic 3D tissue models for advanced high-throughput drug screening
Nam, K.-H., Smith, A. S. T., Lone, S., Kwon, S., & Kim, D.-H. (2015) · SLAS Technology · doi:10.1177/2211068214557813 · Cited by 171
Integrated gut/liver microphysiological systems elucidates inflammatory inter‐tissue crosstalk
Chen, W. L. K., Edington, C., Suter, E., Yu, J., Velazquez, J. J., Velazquez, J. G., Shockley, M., Large, E. M., Venkataramanan, R., Hughes, D. J., et al. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26370 · Cited by 172
Self-citationAnimal tissue culture principles and applications
Verma, A., Verma, M., & Singh, A. (2020) · Animal Biotechnology · doi:10.1016/b978-0-12-811710-1.00012-4 · Cited by 161
Lauschke, V. M., Shafagh, R. Z., Hendriks, D. F. G., & Ingelman‐Sundberg, M. (2019) · Biotechnology Journal · doi:10.1002/biot.201800347 · Cited by 153
A critical perspective on 3D liver models for drug metabolism and toxicology studies
Serras, A. S., Rodrigues, J. S., Cipriano, M., Rodrigues, A. V., Oliveira, N. G., & Miranda, J. P. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.626805 · Cited by 138
Liver-on-a-Chip models of fatty liver disease
Hassan, S., Sebastian, S., Maharjan, S., Lesha, A., Carpenter, A., Liu, X., Xie, X., Livermore, C., Zhang, Y. S., & Zarrinpar, A. (2020) · Hepatology · doi:10.1002/hep.31106 · Cited by 127
Challenges and Opportunities in the Design of Liver-on-Chip Microdevices
Ehrlich, A., Duche, D., Ouedraogo, G., & Nahmias, Y. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052305 · Cited by 125
Belair, D. G., Whisler, J. A., Valdez, J., Velazquez, J., Molenda, J. A., Vickerman, V., Lewis, R., Daigh, C., Hansen, T. D., Mann, D. A., et al. (2015) · Stem Cell Reviews and Reports · doi:10.1007/s12015-014-9549-5 · Cited by 120
Self-citationHuman biomimetic liver microphysiology systems in drug development and precision medicine
Gough, A., Soto-Gutierrez, A., Vernetti, L., Ebrahimkhani, M. R., Stern, A. M., & Taylor, D. L. (2021) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-020-00386-1 · Cited by 117
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Methods to study the tumor microenvironment under controlled oxygen conditions
Byrne, M. B., Leslie, M. T., Gaskins, H. R., & Kenis, P. J. A. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.09.006 · Cited by 104
Hemodynamic flow improves rat hepatocyte morphology, function, and metabolic activity in vitro
Dash, A., Simmers, M. B., Deering, T. G., Berry, D. J., Feaver, R. E., Hastings, N. E., Pruett, T. L., LeCluyse, E. L., Blackman, B. R., & Wamhoff, B. R. (2013) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00331.2012 · Cited by 108
Self-citationPrimary cells and stem cells in drug discovery: emerging tools for high-throughput screening
Eglen, R., & Reisine, T. (2011) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2010.0305 · Cited by 100
Engineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
“A uthor M anuscript A uthor M anuscript A uthor M anuscript A uthor M anuscript Several groups have created co-cultures of PHHs and endothelial cells in microfluidic devices, although primary human LSECs are not always used due to limited availability.”
InfluentialChemical-PDMS binding kinetics and implications for bioavailability in microfluidic devices
Auner, A. W., Tasneem, K. M., Markov, D. A., McCawley, L. J., & Hutson, M. S. (2019) · Lab on a Chip · doi:10.1039/c8lc00796a · Cited by 87
Zhou, Y., Shen, J. X., & Lauschke, V. M. (2019) · Frontiers in Pharmacology · doi:10.3389/fphar.2019.01093 · Cited by 85
Ma, L., Barker, J., Zhou, C., Li, W., Zhang, J., Lin, B., Foltz, G., Küblbeck, J., & Honkakoski, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.02.054 · Cited by 83
Miroshnikova, Y. A., Jorgens, D. M., Spirio, L., Auer, M., Sarang-Sieminski, A. L., & Weaver, V. M. (2011) · Physical Biology · doi:10.1088/1478-3975/8/2/026013 · Cited by 82
A Microphysiological System for Studying Nonalcoholic Steatohepatitis
Kostrzewski, T., Maraver, P., Ouro‐Gnao, L., Levi, A., Snow, S., Miedzik, A., Rombouts, K., & Hughes, D. (2020) · Hepatology Communications · doi:10.1002/hep4.1450 · Cited by 77
Maass, C., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · Integrative Biology · doi:10.1039/c6ib00243a · Cited by 72
Self-citationRivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Balakrishnan, S., Suma, M. S., Raju, S. R., Bhargav, S. D. B., Arunima, S., Das, S., & Ananthasuresh, G. K. (2015) · BioResearch open access · doi:10.1089/biores.2015.0024 · Cited by 20
Human Liver-Derived Extracellular Matrix for the Culture of Distinct Human Primary Liver Cells
Alevra Sarika, N., Payen, V. L., Fléron, M., Ravau, J., Brusa, D., Najimi, M., De Pauw, E., Eppe, G., Mazzucchelli, G., Sokal, E. M., et al. (2020) · Cells · doi:10.3390/cells9061357 · Cited by 18
You-on-a-chip’ for precision medicine
Low, L. A., & Tagle, D. A. (2018) · Expert Review of Precision Medicine and Drug Development · doi:10.1080/23808993.2018.1456333 · Cited by 18
Shirahama, H., Kumar, S. K., Jeon, W.-Y., Kim, M. H., Lee, J. H., Ng, S. S., Tabaei, S. R., & Cho, N.-J. (2016) · Journal of Visualized Experiments · doi:10.3791/54331 · Cited by 14
Boussommier-Calleja, A. (2020) · Bioengineering Innovative Solutions for Cancer · doi:10.1016/b978-0-12-813886-1.00013-9 · Cited by 10
Metadata
- Authors
- Domansky, K., Inman, W., Serdy, J., Dash, A., Lim, M. H. M., & Griffith, L. G.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 1
- Pages
- 51-58
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1517911220
- Cited by
- 444
- References
- 27
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.