Wearable inertial sensors for human movement analysis
Open accessThe DOI matches its Crossref record; 157 of the 157 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. AREAS COVERED: Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-life activity monitoring and tremor assessment. Each area is analyzed both from a methodological and applicative point of view. The focus on the methodological approaches is meant to provide an idea of the computational complexity behind a variable/parameter/index of interest so that the reader is aware of the reliability of the approach. The focus on the application is meant to provide a practical guide for advising clinicians on how inertial sensors can help them in their clinical practice. Expert commentary: Less expensive and more easy to use than other systems used in human movement analysis, wearable sensors have evolved to the point that they can be considered ready for being part of routine clinical routine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Human balance and posture control during standing and walking
Winter, D. (1995) · Gait & Posture · doi:10.1016/0966-6362(96)82849-9 · Cited by 3,421
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Calibration of Accelerometer Output for Children
FREEDSON, P., POBER, D., & JANZ, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,104
Assessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
An introduction to inertial navigation
Woodman, O. J. (2021) · doi:10.48456/tr-696 · Cited by 791
3-D model-based tracking of humans in action: a multi-view approach
Gavrila, D. M., & Davis, L. S. (1996) · Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1996.517056 · Cited by 702
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Acceleration patterns of the head and pelvis when walking on level and irregular surfaces
Menz, H. B., Lord, S. R., & Fitzpatrick, R. C. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00159-5 · Cited by 652
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Estimation of gait cycle characteristics by trunk accelerometry
Moe-Nilssen, R., & Helbostad, J. L. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00233-1 · Cited by 640
Dingwell, J. B., & Marin, L. C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.014 · Cited by 626
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Age-related differences in walking stability
Menz, H. B. (2003) · Age and Ageing · doi:10.1093/ageing/32.2.137 · Cited by 617
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Interlimb Coordination During Locomotion: What Can be Adapted and Stored?
Reisman, D. S., Block, H. J., & Bastian, A. J. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00089.2005 · Cited by 568
Encountering the WorldToward an Ecological Psychology
Reed, E. S. (1997) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195073010.001.0001 · Cited by 529
ISway: a sensitive, valid and reliable measure of postural control
Mancini, M., Salarian, A., Carlson-Kuhta, P., Zampieri, C., King, L., Chiari, L., & Horak, F. B. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-59 · Cited by 499 · cited 3×
“Finally, IMUs proved reliability in assessing the static postural control of both healthy and pathological subjects [115] but, because of the affordability and ease of use of conventional stabilometric platforms, the advantage of using IMUs is not straightforward.”
BackgroundDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491
iTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489 · cited 1×
“cement and velocity), and analysis of turning are provided as well [123].”
BackgroundA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · cited 1×
“angular velocity of thigh and shank as measured by a singleaxis gyroscope [104].”
MethodKinematic determinants of human locomotion.
Borghese, N. A., Bianchi, L., & Lacquaniti, F. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021539 · Cited by 446
Najafi, B., Aminian, K., Loew, F., Blanc, Y., & Robert, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800763 · Cited by 442
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
Moe-Nilssen, R. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00089-8 · Cited by 404
Kinematic measures for assessing gait stability in elderly individuals: a systematic review
Hamacher, D., Singh, N. B., Van Dieën, J. H., Heller, M. O., & Taylor, W. R. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0416 · Cited by 401
Human movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“Bonato [162] supported the idea of this prevision of a further increment also for the potential use of wearable inertial devices in daily-life monitoring patients over extensive periods of time, similar to the ambulatory systems for electrocardiographic monitoring (such as the Holter) which has been part of the routin…”
BackgroundClinical Gait Analysis: Theory and Practice
Kirtley, C. (2006) · Cited by 373
Jasiewicz, J. M., Allum, J. H. J., Middleton, J. W., Barriskill, A., Condie, P., Purcell, B., & Li, R. C. T. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.017 · Cited by 371
Zampieri, C., Salarian, A., Carlson-Kuhta, P., Aminian, K., Nutt, J. G., & Horak, F. B. (2010) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.173740 · Cited by 366
Methods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349 · cited 1×
“The latter can be provided by using a magnetometer, which senses the local magnetic North, used as an absolute reference to reset drift about the vertical direction, so that a full 3D orientation of the sensor in space can be obtained [12,13].”
BackgroundClinical gait analysis. Theory and practice
Maceira-Suárez, E. (2006) · Revista del Pie y Tobillo · Cited by 341
Ambulatory measurement of 3D knee joint angle
Favre, J., Jolles, B. M., Aissaoui, R., & Aminian, K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.12.003 · Cited by 316
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311 · cited 1×
“132] sensors, facing as well the requirement of the sensor-tosegment axes alignment [131,133].”
BackgroundTrunk accelerometry reveals postural instability in untreated Parkinson’s disease
Mancini, M., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Chiari, L. (2011) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2011.05.010 · Cited by 305
Kim, C. M., & Eng, J. J. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2003.07.002 · Cited by 301
Implications of early hominid labyrinthine morphology for evolution of human bipedal locomotion
Spoor, F., Wood, B., & Zonneveld, F. (1994) · Nature · doi:10.1038/369645a0 · Cited by 295
Spain, R. I., St. George, R. J., Salarian, A., Mancini, M., Wagner, J. M., Horak, F. B., & Bourdette, D. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.026 · Cited by 287
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286 · cited 1×
“it from a pair of biaxial accelerometer as done before [102].”
Inertial sensor-based knee flexion/extension angle estimation
Cooper, G., Sheret, I., McMillian, L., Siliverdis, K., Sha, N., Hodgins, D., Kenney, L., & Howard, D. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.004 · Cited by 281
An inertial and magnetic sensor based technique for joint angle measurement
O’Donovan, K. J., Kamnik, R., O’Keeffe, D. T., & Lyons, G. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.010 · Cited by 281
Analysis of the linear displacement of the head and trunk during walking at different speeds
Cappozzo, A. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90059-2 · Cited by 279
Trunk accelerometry as a measure of balance control during quiet standing
Moe-Nilssen, R., & Helbostad, J. L. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00200-4 · Cited by 270
Mobility Lab to Assess Balance and Gait with Synchronized Body-worn Sensors
Laurie King, M. M. (2013) · Journal of Bioengineering and Biomedical Sciences · doi:10.4172/2155-9538.s1-007 · Cited by 268
Bergamini, E., Ligorio, G., Summa, A., Vannozzi, G., Cappozzo, A., & Sabatini, A. (2014) · Sensors · doi:10.3390/s141018625 · Cited by 267
Shoulder and Elbow Joint Angle Tracking With Inertial Sensors
El-Gohary, M., & McNames, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208750 · Cited by 264
Joint kinematics estimate using wearable inertial and magnetic sensing modules
Picerno, P., Cereatti, A., & Cappozzo, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.003 · Cited by 262
Self-citationLamoth, C. J., van Deudekom, F. J., van Campen, J. P., Appels, B. A., de Vries, O. J., & Pijnappels, M. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-2 · Cited by 262
Standing balance evaluation using a triaxial accelerometer
Mayagoitia, R. E., Lötters, J. C., Veltink, P. H., & Hermens, H. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00199-0 · Cited by 249
Moe-Nilssen, R., & Helbostad, J. L. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.01.013 · Cited by 246
Trojaniello, D., Cereatti, A., Pelosin, E., Avanzino, L., Mirelman, A., Hausdorff, J. M., & Della Croce, U. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-152 · Cited by 244
McCamley, J., Donati, M., Grimpampi, E., & Mazzà, C. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.02.019 · Cited by 241
Feature selection of stabilometric parameters based on principal component analysis.
Rocchi, L., Chiari, L., & Cappello, A. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351013 · Cited by 237 · cited 1×
“The parameters related to the center of pressure sway during quite upright standing are sensitive to postural performance and allow for a straightforward and meaningful clinical interpretation of the results [112].”
BackgroundUse of multiple wearable inertial sensors in upper limb motion tracking
Zhou, H., Stone, T., Hu, H., & Harris, N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.010 · Cited by 231
Role of Body-Worn Movement Monitor Technology for Balance and Gait Rehabilitation
Horak, F., King, L., & Mancini, M. (2015) · Physical Therapy · doi:10.2522/ptj.20140253 · Cited by 227
Moe-Nilssen, R. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00090-4 · Cited by 221
‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0545-x · Cited by 218
Lamoth, C. J. C., Meijer, O. G., Wuisman, P. I. J. M., van Dieën, J. H., Levin, M. F., & Beek, P. J. (2002) · Spine · doi:10.1097/00007632-200202150-00016 · Cited by 213
Kinematic variability, fractal dynamics and local dynamic stability of treadmill walking
Terrier, P., & Dériaz, O. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-12 · Cited by 206
Real-time gait event detection for normal subjects from lower trunk accelerations
González, R. C., López, A. M., Rodriguez-Uría, J., Álvarez, D., & Alvarez, J. C. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.11.014 · Cited by 205
Reliability and Validity of Gait Analysis by Android-Based Smartphone
Nishiguchi, S., Yamada, M., Nagai, K., Mori, S., Kajiwara, Y., Sonoda, T., Yoshimura, K., Yoshitomi, H., Ito, H., Okamoto, K., et al. (2012) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0132 · Cited by 204
Analysis of stroke patient walking dynamics using a tri-axial accelerometer
Mizuike, C., Ohgi, S., & Morita, S. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.02.017 · Cited by 202
Long-term monitoring of gait in Parkinson's disease
Moore, S. T., MacDougall, H. G., Gracies, J.-M., Cohen, H. S., & Ondo, W. G. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.011 · Cited by 198
Identification and Validity of Accelerometer Cut‐Points for Toddlers
Trost, S. G., Fees, B. S., Haar, S. J., Murray, A. D., & Crowe, L. K. (2012) · Obesity · doi:10.1038/oby.2011.364 · Cited by 190
Real-time gait event detection using wearable sensors
Hanlon, M., & Anderson, R. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.128 · Cited by 187
Kim, Y., Beets, M. W., & Welk, G. J. (2012) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.12.001 · Cited by 186
Reliability of segmental accelerations measured using a new wireless gait analysis system
Kavanagh, J. J., Morrison, S., James, D. A., & Barrett, R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.09.012 · Cited by 183
Haeuber, E., Shaughnessy, M., Forrester, L. W., Coleman, K. L., & Macko, R. F. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.035 · Cited by 182 · cited 2×
“ease [146], stroke [71], hip arthroplasty [147], chronic diseases [72], elderly [148], and obese [73] populations.”
BackgroundKing, L. A., Horak, F. B., Mancini, M., Pierce, D., Priest, K. C., Chesnutt, J. C., Sullivan, P. M., & Chapman, J. C. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2013.10.015 · Cited by 177
Cooper, A., Page, A., Fox, K., & Misson, J. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601116 · Cited by 172
Wearable systems for monitoring mobility-related activities in older people: a systematic review
de Bruin, E. D., Hartmann, A., Uebelhart, D., Murer, K., & Zijlstra, W. (2008) · Clinical Rehabilitation · doi:10.1177/0269215508090675 · Cited by 170
Audio-Biofeedback Improves Balance in Patients With Bilateral Vestibular Loss
Dozza, M., Chiari, L., & Horak, F. B. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.12.036 · Cited by 169
Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169
Age-related changes in gait for multi-surface terrain
Marigold, D. S., & Patla, A. E. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.09.005 · Cited by 166
Walking speed estimation using a shank-mounted inertial measurement unit
Li, Q., Young, M., Naing, V., & Donelan, J. M. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.031 · Cited by 166
Lau, H., & Tong, K. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.03.018 · Cited by 165
Aminian, K., Trevisan, C., Najafi, B., Dejnabadi, H., Frigo, C., Pavan, E., Telonio, A., Cerati, F., Marinoni, E. C., Robert, P., et al. (2004) · Gait & Posture · doi:10.1016/s0966-6362(03)00093-6 · Cited by 164
Characteristics of physiologic tremor in young and elderly adults
Elble, R. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00006-3 · Cited by 163
Bilateral step length estimation using a single inertial measurement unit attached to the pelvis
Köse, A., Cereatti, A., & Croce, U. D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-9 · Cited by 150
Doi, T., Hirata, S., Ono, R., Tsutsumimoto, K., Misu, S., & Ando, H. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-7 · Cited by 149
Fall detection with body-worn sensors: A systematic review
for the FARSEEING Consortium and the FARSEEING Meta Database Consensus Group, Schwickert, L., Becker, C., Lindemann, U., Maréchal, C., Bourke, A., Chiari, L., Helbostad, J. L., Zijlstra, W., Aminian, K., et al. (2013) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s00391-013-0559-8 · Cited by 148
Nelson-Wong, E., Howarth, S. J., Winter, D. A., & Callaghan, J. P. (2009) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2009.2969 · Cited by 146
Trojaniello, D., Ravaschio, A., Hausdorff, J. M., & Cereatti, A. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.06.008 · Cited by 145
Senden, R. H. J., Savelberg, H. H. C. M., Grimm, B. P., Heyligers, I. C., & Meijer, K. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.03.015 · Cited by 137
Dijkstra, B., Zijlstra, W., Scherder, E., & Kamsma, Y. P. T. (2008) · Age and Ageing · doi:10.1093/ageing/afn097 · Cited by 132
Trojaniello, D., Cereatti, A., & Croce, U. D. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.07.007 · Cited by 131
Real-time gait assessment utilizing a new way of accelerometry
Willemsen, A., van Alste, J. A., & Boom, H. B. K. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90033-y · Cited by 130
A body-fixed-sensor-based analysis of power during sit-to-stand movements
Zijlstra, W., Bisseling, R. W., Schlumbohm, S., & Baldus, H. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.11.003 · Cited by 129
Audio-Biofeedback training for posture and balance in Patients with Parkinson's disease
Mirelman, A., Herman, T., Nicolai, S., Zijlstra, A., Zijlstra, W., Becker, C., Chiari, L., & Hausdorff, J. M. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-35 · Cited by 125
Control of the upper body accelerations in young and elderly women during level walking
Mazzà, C., Iosa, M., Pecoraro, F., & Cappozzo, A. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-30 · Cited by 124
Self-citationAdaptive step length estimation algorithm using optimal parameters and movement status awareness
Shin, S. H., & Park, C. G. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.04.009 · Cited by 120
Wearable Systems for Monitoring Mobility-Related Activities in Chronic Disease: A Systematic Review
Allet, L., Knols, R. H., Shirato, K., & Bruin, E. D. D. (2010) · Sensors · doi:10.3390/s101009026 · Cited by 118
Seven Capital Devices for the Future of Stroke Rehabilitation
Iosa, M., Morone, G., Fusco, A., Bragoni, M., Coiro, P., Multari, M., Venturiero, V., De Angelis, D., Pratesi, L., & Paolucci, S. (2012) · Stroke Research and Treatment · doi:10.1155/2012/187965 · Cited by 117
Self-citationLower trunk motion and speed-dependence during walking
Kavanagh, J. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-9 · Cited by 112
Effects of Aging on the Regularity of Physiological Tremor
Sturman, M. M., Vaillancourt, D. E., & Corcos, D. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01218.2004 · Cited by 111
Development and Decline of Upright Gait Stability
Iosa, M., Fusco, A., Morone, G., & Paolucci, S. (2014) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2014.00014 · Cited by 111
Self-citationLeardini, A., Lullini, G., Giannini, S., Berti, L., Ortolani, M., & Caravaggi, P. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-136 · Cited by 110
Heinze, F., Hesels, K., Breitbach‐Faller, N., Schmitz‐Rode, T., & Dißelhorst-Klug, C. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0624-z · Cited by 104
Automated gait and balance parameters diagnose and correlate with severity in Parkinson disease
Dewey, D. C., Miocinovic, S., Bernstein, I. H., Khemani, P., Dewey, R. B., QUERRY, R. G., Chitnis, S., & Dewey, R. B. (2014) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2014.07.026 · Cited by 102
Veltink, P. H., Slycke, P., Hemssems, J., Buschman, R., Bultstra, G., & Hermens, H. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00041-3 · Cited by 99
van Lummel, R. C., Ainsworth, E., Lindemann, U., Zijlstra, W., Chiari, L., van Campen, P., & Hausdorff, J. M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.10.008 · Cited by 99
Estimation of Upper-Limb Orientation Based on Accelerometer and Gyroscope Measurements
Hyde, R. A., Ketteringham, L. P., Neild, S. A., & Jones, R. J. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912647 · Cited by 98
Pérez, R., Costa, Ú., Torrent, M., Solana, J., Opisso, E., Cáceres, C., Tormos, J. M., Medina, J., & Gómez, E. J. (2010) · Sensors · doi:10.3390/s101210733 · Cited by 97
Favre, J., Lüthi, F., Jolles, B. M., Siegrist, O., Najafi, B., & Aminian, K. (2006) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-005-0023-4 · Cited by 96
Gait analysis in children with cerebral palsy via inertial and magnetic sensors
van den Noort, J. C., Ferrari, A., Cutti, A. G., Becher, J. G., & Harlaar, J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1006-5 · Cited by 93
Zijlstra, A., Mancini, M., Lindemann, U., Chiari, L., & Zijlstra, W. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-75 · Cited by 92
Dijkstra, B., Kamsma, Y. P. T., & Zijlstra, W. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.05.004 · Cited by 91
A spot check for assessing static orientation consistency of inertial and magnetic sensing units
Picerno, P., Cereatti, A., & Cappozzo, A. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2010.12.006 · Cited by 90
Self-citationFrailty assessment based on wavelet analysis during quiet standing balance test
Martínez-Ramírez, A., Lecumberri, P., Gómez, M., Rodríguez‐Mañas, L., García‐García, F. J., & Izquierdo, M. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.06.007 · Cited by 83
Examination of Different Accelerometer Cut-Points for Assessing Sedentary Behaviors in Children
Kim, Y., Lee, J. M., Peters, B. P., Gaesser, G. A., & Welk, G. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090630 · Cited by 82
Gravitational artifact in accelerometric measurements of tremor
Elble, R. J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.03.014 · Cited by 82
Classification and Treatment of Tremor
Hallett, M. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470080085035 · Cited by 81
(1999) · PubMed · Cited by 77
Stability and harmony of gait in children with cerebral palsy
Iosa, M., Marro, T., Paolucci, S., & Morelli, D. (2011) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2011.08.031 · Cited by 75
Self-citationExploring Outcome Measures for Exercise Intervention in People with Parkinson’s Disease
King, L. A., Salarian, A., Mancini, M., Priest, K. C., Nutt, J. G., Serdar, A., Wilhelm, J., Schlimgen, J., Smith, M., & Horak, F. B. (2013) · Parkinson s Disease · doi:10.1155/2013/572134 · Cited by 73
Parel, I., Cutti, A. G., Fiumana, G., Porcellini, G., Verni, G., & Accardo, A. P. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.12.015 · Cited by 73
Technical and clinical view on ambulatory assessment in Parkinson's disease
Hobert, M. A., Maetzler, W., Aminian, K., & Chiari, L. (2014) · Acta Neurologica Scandinavica · doi:10.1111/ane.12248 · Cited by 72
Pasciuto, I., Ligorio, G., Bergamini, E., Vannozzi, G., Sabatini, A. M., & Cappozzo, A. (2015) · Sensors · doi:10.3390/s150923983 · Cited by 72
Zoccolillo, L., Morelli, D., Febo Cincotti, A., Muzzioli, L., Gobbetti, T., Paolucci, S., & Iosa, M. (2015) · PubMed · Cited by 71
Self-citationNegative results: negative perceptions limit their potential for increasing reproducibility
da Silva, J. A. T. (2015) · Journal of Negative Results in BioMedicine · doi:10.1186/s12952-015-0033-9 · Cited by 65
Solomon, A. J., Jacobs, J. V., Lomond, K. V., & Henry, S. M. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0066-9 · Cited by 65
Calibration of Accelerometer Output for Ambulatory Adults With Multiple Sclerosis
Motl, R. W., Snook, E. M., Agiovlasitis, S., & Suh, Y. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.03.020 · Cited by 64
Quantifying freezing of gait in Parkinson's disease during the instrumented timed up and go test
Mancini, M., Priest, K. C., Nutt, J. G., & Horak, F. B. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346151 · Cited by 64
Effects of Walking Endurance Reduction on Gait Stability in Patients with Stroke
Iosa, M., Morone, G., Fusco, A., Pratesi, L., Bragoni, M., Coiro, P., Multari, M., Venturiero, V., Angelis, D. D., & Paolucci, S. (2011) · Stroke Research and Treatment · doi:10.1155/2012/810415 · Cited by 58
Self-citationAn Ambulatory Method of Identifying Anterior Cruciate Ligament Reconstructed Gait Patterns
Patterson, M., Delahunt, E., Sweeney, K. T., & Caulfield, B. M. (2014) · Sensors · doi:10.3390/s140100887 · Cited by 57
Classification of normal and pathological tremors using a multidimensional electromagnetic system
Spyers-Ashby, J. M., Stokes, M. J., Bain, P. G., & Roberts, S. J. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00004-7 · Cited by 54
Accelerometer Cut Points for Physical Activity Assessment of Older Adults with Parkinson’s Disease
Nero, H., Wallén, M. B., Franzén, E., Ståhle, A., & Hagströmer, M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135899 · Cited by 54
Duval, C., & Jones, J. L. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-2233-x · Cited by 53
Marchetti, G. F., Bellanca, J. L., Whitney, S. L., Lin, J. C.-C., Musolino, M. C., Furman, G. R., & Redfern, M. S. (2013) · Journal of Vestibular Research · doi:10.3233/ves-130490 · Cited by 52
Ricci, L., Formica, D., Sparaci, L., Lasorsa, F. R., Taffoni, F., Tamilia, E., & Guglielmelli, E. (2014) · Sensors · doi:10.3390/s140101057 · Cited by 51
Iosa, M., Paradisi, F., Brunelli, S., Delussu, A. S., Pellegrini, R. G., Zenardi, D., Paolucci, S., & Traballesi, M. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2013.07.0162 · Cited by 51
Self-citationTest–retest reliability of sensor-based sit-to-stand measures in young and older adults
Regterschot, G. R. H., Zhang, W., Baldus, H., Stevens, M. J., & Zijlstra, W. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.193 · Cited by 50
Postural strategies assessed with inertial sensors in healthy and parkinsonian subjects
Baston, C., Mancini, M., Schoneburg, B., Horak, F. B., & Rocchi, L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.02.012 · Cited by 50
Mobility assessment of patients with facioscapulohumeral dystrophy
Iosa, M., Mazzà, C., Frusciante, R., Zok, M., Aprile, I. G., Ricci, E., & Cappozzo, A. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.07.013 · Cited by 49
Self-citationHead and Body Coordination during Locomotion and Complex Movements
Berthoz, A., & Pozzo, T. (1994) · Elsevier eBooks · doi:10.1016/b978-0-12-679270-6.50012-7 · Cited by 48
Evaluation of an inertial sensor system for analysis of timed-up-and-go under dual-task demands
Coulthard, J. T., Treen, T. T., Oates, A., & Lanovaz, J. L. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.03.009 · Cited by 48
Self-Assessment Tool of Disease Activity of Rheumatoid Arthritis by Using a Smartphone Application
Nishiguchi, S., Ito, H., Yamada, M., Yoshitomi, H., Furu, M., Ito, T., Shinohara, A., Ura, T., Okamoto, K., & Aoyama, T. (2014) · Telemedicine and e-Health · doi:10.1089/tmj.2013.0162 · Cited by 45
Iosa, M., Mazzà, C., Pecoraro, F., Aprile, I. G., Ricci, E., & Cappozzo, A. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.08.247 · Cited by 44
Self-citationde Bruin, E. D., Hubli, M., Hofer, P., Wolf, P., Murer, K., & Zijlstra, W. (2012) · Journal of Aging Research · doi:10.1155/2012/954378 · Cited by 41
Regterschot, G. R. H., Zhang, W., Baldus, H., Stevens, M. J., & Zijlstra, W. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.03.350 · Cited by 39
Habitual Physical Activity Behavior of Patients After Primary Total Hip Arthroplasty
Wagenmakers, R., Stevens, M. J., Zijlstra, W., Jacobs, M. L., van den Akker‐Scheek, I., Groothoff, J. W., & Bulstra, S. K. (2008) · Physical Therapy · doi:10.2522/ptj.20070375 · Cited by 39
Raya, R., Rocón, E., Gallego, J. Á., Ceres, R., & Pons, J. L. (2012) · Sensors · doi:10.3390/s120303049 · Cited by 37
Henchoz, Y., Soldini, N., Peyrot, N., & Malatesta, D. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3227-4 · Cited by 36
van Lummel, R. C., Ainsworth, E., Hausdorff, J. M., Lindemann, U., Beek, P. J., & van Dieën, J. H. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1855 · Cited by 34
Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor
Picerno, P., Viero, V., Donati, M., Triossi, T., Tancredi, V., & Melchiorri, G. (2015) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.06.0146 · Cited by 30
Self-citationPellegrini, A., Tonino, P. M., Paladini, P., Cutti, A. G., Ceccarelli, F., & Porcellini, G. (2013) · MUSCULOSKELETAL SURGERY · doi:10.1007/s12306-013-0253-4 · Cited by 28
Biobehavioral Intervention for Older Adults Coping with Essential Tremor
Lundervold, D. A., & Poppen, R. L. (2004) · Applied Psychophysiology and Biofeedback · doi:10.1023/b:apbi.0000017864.06525.eb · Cited by 17
Raya, R., Rocón, E., Ceres, R., Harlaar, J., & Geytenbeek, J. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975409 · Cited by 15
Tremor: classification, diagnosis and management.
Sandroni, P., & Rr, Y. (1994) · PubMed · Cited by 10
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Sensors for daily life: A review
Javaid, M., Haleem, A., Rab, S., Pratap Singh, R., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100121 · Cited by 430
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Validity and repeatability of inertial measurement units for measuring gait parameters
Washabaugh, E. P., Kalyanaraman, T., Adamczyk, P. G., Claflin, E. S., & Krishnan, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.013 · Cited by 329
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Metadata
- Authors
- Iosa, M., Picerno, P., Paolucci, S., & Morone, G.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2016-06-17
- Volume
- 13
- Issue
- 7
- Pages
- 641-659
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2428043126
- Cited by
- 281
- References
- 157
- FWCI
- 15.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.