Abstract
Recent demand and interest in wireless, mobile-based healthcare has driven significant interest towards developing alternative biopotential electrodes for patient physiological monitoring. The conventional wet adhesive Ag/AgCl electrodes used almost universally in clinical applications today provide an excellent signal but are cumbersome and irritating for mobile use. While electrodes that operate without gels, adhesives and even skin contact have been known for many decades, they have yet to achieve any acceptance for medical use. In addition, detailed knowledge and comparisons between different electrodes are not well known in the literature. In this paper, we explore the use of dry/noncontact electrodes for clinical use by first explaining the electrical models for dry, insulated and noncontact electrodes and show the performance limits, along with measured data. The theory and data show that the common practice of minimizing electrode resistance may not always be necessary and actually lead to increased noise depending on coupling capacitance. Theoretical analysis is followed by an extensive review of the latest dry electrode developments in the literature. The paper concludes with highlighting some of the novel systems that dry electrode technology has enabled for cardiac and neural monitoring followed by a discussion of the current challenges and a roadmap going forward.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Driven-right-leg circuit design
Winter, B. B., & Webster, J. G. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325168 · Cited by 443
Investigation into the origin of the noise of surface electrodes
Huigen, E., Peper, A., & Grimbergen, C. A. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344216 · Cited by 353
Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
Tallgren, P., Vanhatalo, S., Kaila, K., & Voipio, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.10.001 · Cited by 344
Skin impedance from 1 Hz to 1 MHz
Rosell, J., Colominas, J., Riu, P., Pallas-Areny, R., & Webster, J. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4599 · Cited by 343
Flexible polymeric dry electrodes for the long-term monitoring of ECG
Baek, J.-Y., An, J.-H., Choi, J.-M., Park, K.-S., & Lee, S.-H. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.11.019 · Cited by 340
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310 · cited 1×
“proven signal modalities provide a wealth of physiological information, which by virtue of modern bioinstrumentation technology can be harnessed noninvasively and inexpensively for the emerging global health applications of clinical physiological monitoring and medical treatment [ 1 ], [2].”
BackgroundAn ultra-wearable, wireless, low power ECG monitoring system
Park, C., Chou, P. H., Bai, Y., Matthews, R., & Hibbs, A. (2006) · 2006 IEEE Biomedical Circuits and Systems Conference · doi:10.1109/biocas.2006.4600353 · Cited by 262
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Yang, G., Xie, L., Mäntysalo, M., Zhou, X., Pang, Z., Xu, L. D., Kao-Walter, S., Chen, Q., & Zheng, L.-R. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2307795 · Cited by 696
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Lopez-Gordo, M., Sanchez-Morillo, D., & Valle, F. (2014) · Sensors · doi:10.3390/s140712847 · Cited by 410
Gu, X., Cao, Z., Jolfaei, A., Xu, P., Wu, D., Jung, T.-P., & Lin, C.-T. (2021) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2021.3052811 · Cited by 395
Self-citationTian, L., Zimmerman, B., Akhtar, A., Yu, K. J., Moore, M., Wu, J., Larsen, R. J., Lee, J. W., Li, J., Liu, Y., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0347-x · Cited by 393
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Casson, A. J. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-00093-6 · Cited by 340
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Non-contact heart rate and heart rate variability measurements: A review
Kranjec, J., Beguš, S., Geršak, G., & Drnovšek, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.004 · Cited by 318
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K. (2019) · Electronics · doi:10.3390/electronics8050479 · Cited by 315
Campana, A., Cramer, T., Simon, D. T., Berggren, M., & Biscarini, F. (2014) · Advanced Materials · doi:10.1002/adma.201400263 · Cited by 314
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Self-citationDry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces
Chi, Y. M., Wang, Y.-T., Wang, Y., Maier, C., Jung, T.-P., & Cauwenberghs, G. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2174652 · Cited by 297
Self-citationWang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
Mixed Neural Network Approach for Temporal Sleep Stage Classification
Dong, H., Supratak, A., Pan, W., Wu, C., Matthews, P. M., & Guo, Y. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2733220 · Cited by 295
A Review on the Computational Methods for Emotional State Estimation from the Human EEG
Kim, M.-K., Kim, M., Oh, E., & Kim, S.-P. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/573734 · Cited by 293
Tutorial. Surface EMG detection in space and time: Best practices
Merletti, R., & Muceli, S. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.102363 · Cited by 290
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Dry electrodes for electrocardiography
Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/r47 · Cited by 288
Capacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288
Zhang, Q., Zhou, D., & Zeng, X. (2017) · IEEE Access · doi:10.1109/access.2017.2707460 · Cited by 282
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Self-citationSoft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D.-H., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 272
The neurophysiological bases of EEG and EEG measurement: A review for the rest of us
Jackson, A. F., & Bolger, D. J. (2014) · Psychophysiology · doi:10.1111/psyp.12283 · Cited by 264
Liao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 258
Human Brain Distinctiveness Based on EEG Spectral Coherence Connectivity
Rocca, D. L., Campisi, P., Vegso, B., Cserti, P., Kozmann, G., Babiloni, F., & Fallani, F. D. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2317881 · Cited by 256
Graphene-clad textile electrodes for electrocardiogram monitoring
Yapici, M. K., Alkhidir, T., Samad, Y. A., & Liao, K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.111 · Cited by 239
Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
Chen, Y.-H., De Beeck, M., Vanderheyden, L., Carrette, E., Mihajlović, V., Vanstreels, K., Grundlehner, B., Gadeyne, S., Boon, P., & Van Hoof, C. (2014) · Sensors · doi:10.3390/s141223758 · Cited by 238
“Commercially available dry electrode recording systems are equipped with metal-coated or metal electrodes [2].”
BackgroundSmartwatch-Based Wearable EEG System for Driver Drowsiness Detection
Li, G., Lee, B.-L., & Chung, W.-Y. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2473679 · Cited by 236
“For dry electrodes, the noise caused by irregular movements is inevitable [36] and some”
BackgroundWearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231
Imaging natural cognition in action
Gramann, K., Ferris, D. P., Gwin, J., & Makeig, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.003 · Cited by 227
Consumer grade EEG devices: are they usable for control tasks?
Maskeliunas, R., Damasevicius, R., Martisius, I., & Vasiljevas, M. (2016) · PeerJ · doi:10.7717/peerj.1746 · Cited by 210
Nawrocki, R. A., Jin, H., Lee, S., Yokota, T., Sekino, M., & Someya, T. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201803279 · Cited by 206
Li, G., Wang, S., & Duan, Y. Y. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.08.155 · Cited by 203
Mobile EEG in research on neurodevelopmental disorders: Opportunities and challenges
Lau-Zhu, A., Lau, M. P. H., & McLoughlin, G. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100635 · Cited by 201
Application of intrinsically conducting polymers in flexible electronics
Ouyang, J. (2021) · SmartMat · doi:10.1002/smm2.1059 · Cited by 197
Evolution, Current Challenges, and Future Possibilities in ECG Biometrics
Ribeiro Pinto, J., Cardoso, J. S., & Lourenco, A. (2018) · IEEE Access · doi:10.1109/access.2018.2849870 · Cited by 195
“[67] have developed and evaluated electrodes that dismiss the need for contact, successfully acquiring ECG through layers of plastic or clothes.”
BackgroundLee, S. M., Byeon, H. J., Lee, J. H., Baek, D. H., Lee, K. H., Hong, J. S., & Lee, S.-H. (2014) · Scientific Reports · doi:10.1038/srep06074 · Cited by 181
Liao, L.-D., Wang, I.-J., Chen, S.-F., Chang, J.-Y., & Lin, C.-T. (2011) · Sensors · doi:10.3390/s110605819 · Cited by 181
“measured directly with the conductive method, and the influence of the stratum corneum can be effectively reduced [9].”
BackgroundMethodInfluentialHuynh, T. H., Jafari, R., & Chung, W.-Y. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2865751 · Cited by 178
“45 mm and a surface resistivity lower than 1Ω/sq [29].”
BackgroundReview of semi-dry electrodes for EEG recording
Li, G.-L., Wu, J.-T., Xia, Y.-H., He, Q.-G., & Jin, H.-G. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbd50 · Cited by 178
Ambient and Unobtrusive Cardiorespiratory Monitoring Techniques
Bruser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
“Minimization and detection of artifacts: The high-input impedance results in a high sensitivity to electrostatic charges, which introduce severe artifacts [70], [96].”
BackgroundCapacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174
Kappel, S. L., Rank, M. L., Toft, H. O., Andersen, M., & Kidmose, P. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2835778 · Cited by 172
“When using dry-contact electrodes, no electrode gel is applied between the electrodes and the skin, instead the instrumentation and electrodes are designed to accommodate and reduce the effect of variations in the electrode-skin interface [6], [7].”
BackgroundMethodBiosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L.-D., Lin, C.-T., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T.-P., Ko, L.-W., & Chang, J.-Y. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 169
Self-citationNanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review
Yao, S., & Zhu, Y. (2016) · JOM · doi:10.1007/s11837-016-1818-0 · Cited by 166
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
“HR from ECGs [32], [33].”
Large-Scale Distributed Dedicated- and Non-Dedicated Smart City Sensing Systems
Habibzadeh, H., Qin, Z., Soyata, T., & Kantarci, B. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2725638 · Cited by 114
“applications utilize either dry or non-contact electrodes [36] to capture ECG.”
MethodA Wearable, Multimodal Sensing System to Monitor Knee Joint Health
Teague, C. N., Heller, J. A., Nevius, B. N., Carek, A. M., Mabrouk, S., Garcia-Vicente, F., Inan, O. T., & Etemadi, M. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2994552 · Cited by 66
Wireless Capacitive-Based ECG Sensing for Feature Extraction and Mobile Health Monitoring
Wannenburg, J., Malekian, R., & Hancke, G. P. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2844122 · Cited by 66
Conductively coupled flexible silicon electronic systems for chronic neural electrophysiology
Li, J., Song, E., Chiang, C.-H., Yu, K. J., Koo, J., Du, H., Zhong, Y., Hill, M., Wang, C., Zhang, J., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813187115 · Cited by 65
“Although useful in many scenarios of interest, the fundamental design requires that the capacitance between each t-SiO2–coated sensing electrode and the surrounding tissue must be at least one order of magnitude larger than that of the capacitance associated with the gate of the corresponding sensing transistor to avo…”
BackgroundDabbaghian, A., Yousefi, T., Fatmi, S. Z., Shafia, P., & Kassiri, H. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2936327 · Cited by 56
A Digitally Assisted, Signal Folding Neural Recording Amplifier
Chen, Y., Basu, A., Liu, L., Zou, X., Rajkumar, R., Dawe, G. S., & Je, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2288680 · Cited by 43
“Another example of a commonly encountered interference signal in the recording of bio-potentials is motion artifact [24], [25].”
BackgroundBenchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
“Whilethe first BCIs were inaccurate, cumbersome and time-consuming to apply, advances such as dry (Chi et al., 2010) or water-based (Volosyak et al., 2010) electrodes and new sensor fusion methods (Müller-Putz et al., 2015; Novak and Riener, 2015) have significantly increased both their performance…”
MethodStephens-Fripp, B., Sencadas, V., Mutlu, R., & Alici, G. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00179 · Cited by 29
“Removing the adhesive that is often used in disposable and reusable electrodes, could reduce the level of irritation on the skin, and reduction in performance over time (Chi et al., 2010; Yao and Zhu, 2016).”
BackgroundAllado, E., Poussel, M., Moussu, A., Saunier, V., Bernard, Y., Albuisson, E., & Chenuel, B. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047896 · Cited by 22
Metadata
- Authors
- Chi, Y. M., Jung, T.-P., & Cauwenberghs, G.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2010
- Volume
- 3
- Pages
- 106-119
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2126390573
- Cited by
- 1,061
- References
- 50
- FWCI
- 19.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.