Investigating sources of inaccuracy in wearable optical heart rate sensors
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index; 19 of the 50 sources its claims cite were checked for support.
Abstract
As wearable technologies are being increasingly used for clinical research and healthcare, it is critical to understand their accuracy and determine how measurement errors may affect research conclusions and impact healthcare decision-making. Accuracy of wearable technologies has been a hotly debated topic in both the research and popular science literature. Currently, wearable technology companies are responsible for assessing and reporting the accuracy of their products, but little information about the evaluation method is made publicly available. Heart rate measurements from wearables are derived from photoplethysmography (PPG), an optical method for measuring changes in blood volume under the skin. Potential inaccuracies in PPG stem from three major areas, includes (1) diverse skin types, (2) motion artifacts, and (3) signal crossover. To date, no study has systematically explored the accuracy of wearables across the full range of skin tones. Here, we explored heart rate and PPG data from consumer- and research-grade wearables under multiple circumstances to test whether and to what extent these inaccuracies exist. We saw no statistically significant difference in accuracy across skin tones, but we saw significant differences between devices, and between activity types, notably, that absolute error during activity was, on average, 30% higher than during rest. Our conclusions indicate that different wearables are all reasonably accurate at resting and prolonged elevated heart rate, but that differences exist between devices in responding to changes in activity. This has implications for researchers, clinicians, and consumers in drawing study conclusions, combining study results, and making health-related decisions using these devices.
Overview
CoChat Summary
## TL;DR
This study tested six wearable optical heart-rate devices in 53 participants across the full Fitzpatrick skin-tone scale, using ECG as the reference standard. The main drivers of error were device type and activity condition, not skin tone.
## Key findings
- Across all devices, there was no statistically significant difference in heart-rate accuracy across skin tones; the authors also report no differences in HRV accuracy between skin-tone groups.
- At rest, consumer-grade wearables were more accurate than research-grade wearables: MAE was 7.2 ± 5.4 bpm vs 13.9 ± 7.8 bpm (p < 0.0125).
- During physical activity, error increased for both categories: MAE was 10.2 ± 7.5 bpm for consumer devices vs 15.9 ± 8.1 bpm for research devices (p < 0.0125); the abstract also states absolute error during activity was 30% higher than during rest.
- Device performance varied substantially: at rest, the Apple Watch 4 had the lowest MAE among consumer devices (4.4 bpm) and the Empatica E4 the lowest among research devices (11.3 bpm); during activity, the Apple Watch 4 remained lowest (4.6 bpm) while the Biovotion Everion was highest among research devices (19.8 bpm).
## Methods
- Design/sample: Observational validation study of 56 recruited participants, with 53 completing the protocol; participants were 18–54 years old, with an approximately equal distribution across six Fitzpatrick skin-tone categories.
- Devices/protocol: Six wearables were tested—4 consumer-grade (Apple Watch 4, Fitbit Charge 2, Garmin Vivosmart 3, Xiaomi Miband 3) and 2 research-grade (Empatica E4, Biovotion Everion)—during rest, deep breathing, walking, washout, and typing, with ECG (Bittium Faros 180) as the reference standard.
- Analysis: The paper compared wearable HR to ECG using MAE, MDE, missingness, and HRV analyses, with mixed-effects models for skin tone, condition, device, and interactions, plus t tests and Bonferroni corrections.
## Limitations
- The authors state that the study had a limited scope of devices, so they could not tease apart the separate effects of cost, market size, and release year.
- For HRV, analysis was limited to only the Empatica E4, because most wearables did not provide the raw data needed for HRV calculations.
- Evident from the text: the protocol was short and structured (about 1 hour of seated rest, deep breathing, walking, and typing), so the findings may not generalize to other activities or longer-term real-world use.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
5 Valid · 4 Not valid · 8 Not checked · 77 Own results and interpretations
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“Our analyses reinforces the growing body of research demonstrating that wearable devices have higher error during activity than at rest.8,11,35,38,39”
§ Investigating sources of inaccuracy in wearable optical heart rate sensors > Discussion
What the sources say
- Not checked — no full text of the sourcecites [8] Jo, E., Lewis, K., Directo, D., Kim, M. J. & Dolezal, B. A. Validation of biofeedback wearables for photoplethysmographic heart rate tracking. J. Sports Sci. Med.15, 540–547 (2016). PMC4974868 27803634
- Disputedcites [11] Shcherbina A Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort J. Pers. Med. 2017 7 3 10.3390/jpm7020003 PMC5491979 28538708 sourceExperimental — accuracy not yet measured
The Results (§3.2; page unavailable) report the opposite for energy expenditure: error was highest while sitting and lower during walking and running. The paper also finds that heart-rate error varies by activity rather than establishing that it is generally higher during activity than at rest (§3.1 and §3.4). (LLM, conf=0.87)
Checked by a reasoning model — may be wrong.
- Partly supportedcites [35] Zhang Y Motion artifact reduction for wrist-worn photoplethysmograph sensors based on different wavelengths Sensors 2019 19 673 10.3390/s19030673 PMC6387309 30736395 sourceExperimental — accuracy not yet measured
The Introduction says motion can distort wrist-worn PPG signals, and Section 4.1 reports a higher peak-to-noise ratio in stationary conditions than in several motion conditions. These passages support the direction of the claim for wrist-worn PPG, but the paper does not establish that wearable devices generally have higher measurement error during activity than at rest. (LLM, conf=0.78)
- Not checked — no full text of the sourcecites [38] Zong, C. & Jafari, R. Robust heart rate estimation using wrist-based PPG signals in the presence of intense physical activities. in 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 8078–8082. 10.1109/EMBC.2015.7320268 (IEEE, 2015). 26738168 source
- Could not verifycites [39] Reis VM Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? PLoS ONE 2019 14 e0221284 10.1371/journal.pone.0221284 31437191 PMC6705857 sourceExperimental — accuracy not yet measured
The Results and Conclusions report estimation errors during low-intensity resistance exercise, but do not compare them with errors at rest. A search for resting measurements and an activity-versus-rest accuracy comparison found no passage addressing that comparison in our copy. (LLM, conf=0.76)
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Several research groups and manufacturers have identified that cyclical motion can affect accuracy of HR in wearable sensors.”
§ Investigating sources of inaccuracy in wearable optical heart rate sensors > Introduction
What the sources say
- Supportedcites [9] Reddy RK Accuracy of wrist-worn activity monitors during common daily physical activities and types of structured exercise: evaluation study JMIR mHealth uHealth 2018 6 e10338 10.2196/10338 30530451 PMC6305876 source
The Results (Heart Rate Accuracy; page not supplied) report significantly different heart-rate errors between activities with and without repetitive upper-torso motion. The Discussion (Principal Findings; page not supplied) likewise says accuracy differed with repetitive wrist motion. These findings support the claim that cyclical motion can affect wearable heart-rate accuracy, without implying that it necessarily worsens it. (LLM, conf=0.91)
- Supportedcites [10] Sartor F Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients BMC Sports Sci. Med. Rehabil. 2018 10 10 10.1186/s13102-018-0098-0 29881626 PMC5984393 source
The Background explains that motion artifacts distort the PPG signal used by wearable heart-rate monitors and that filtering them is especially challenging during periodic motion. This supports the claim that cyclical motion can affect heart-rate accuracy. (LLM, conf=0.91)
- Not matchedcites [15] Apple Support. Get the most accurate measurements using your Apple Watch—Apple Support. https://support.apple.com/en-us/HT207941#heartrate (2019).
Its entry has no title and year that we can search by.
plainstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Several studies have demonstrated that HR measurements from wearable devices are often less accurate during physical activity or cyclic wrist motions.”
§ Investigating sources of inaccuracy in wearable optical heart rate sensors > Introduction
What the sources say
- Not checked — no full text of the sourcecites [8] Jo, E., Lewis, K., Directo, D., Kim, M. J. & Dolezal, B. A. Validation of biofeedback wearables for photoplethysmographic heart rate tracking. J. Sports Sci. Med.15, 540–547 (2016). PMC4974868 27803634
- Partly supportedcites [11] Shcherbina A Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort J. Pers. Med. 2017 7 3 10.3390/jpm7020003 PMC5491979 28538708 sourceExperimental — accuracy not yet measured
The Discussion reports higher heart-rate error at higher intensity within each activity, and Results §3.1 reports more error during walking than cycling. But the paper does not assess cyclic wrist motions, and its Conclusions say heart-rate measurements were within an acceptable error range in most activity settings; it does not support a general claim that physical activity makes them less accurate. (LLM, conf=0.84)
- Supportedcites [35] Zhang Y Motion artifact reduction for wrist-worn photoplethysmograph sensors based on different wavelengths Sensors 2019 19 673 10.3390/s19030673 PMC6387309 30736395 source
The Introduction states that motions during ambulatory monitoring can distort wrist-worn PPG signals and that motion artifacts can overlap the heart-rate signal. The Results and Discussion assess heart-rate estimation error during motion, supporting the claim that wearable heart-rate measurements can be less accurate during activity or wrist motion. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites [38] Zong, C. & Jafari, R. Robust heart rate estimation using wrist-based PPG signals in the presence of intense physical activities. in 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 8078–8082. 10.1109/EMBC.2015.7320268 (IEEE, 2015). 26738168 source
- Partly supportedcites [39] Reis VM Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? PLoS ONE 2019 14 e0221284 10.1371/journal.pone.0221284 31437191 PMC6705857 sourceExperimental — accuracy not yet measured
The Discussion reports that some wearable HR devices had errors above 10% when used to predict energy cost during higher-intensity resistance exercise, while this study found errors below 10% at low intensity. That supports a narrower, activity-dependent concern about energy-cost estimates, not the claim that HR measurements themselves are often less accurate during physical activity; the paper does not address cyclic wrist motions. Our copy provides no page numbers for these passages. (LLM, conf=0.82)
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“previous research demonstrated that inaccurate PPG HR measurements occur up to 15% more frequently in dark skin as compared to light skin”
§ Investigating sources of inaccuracy in wearable optical heart rate sensors > Introduction
What the sources say
- Not checked — no full text of the sourcecites [23] Zonios G Bykowski J Kollias N Skin melanin, hemoglobin, and light scattering properties can be quantitatively assessed in vivo using diffuse reflectance spectroscopy J. Invest. Dermatol. 2001 117 1452 1457 10.1046/j.0022-202x.2001.01577.x 11886508 source
- Could not verifycites [24] Tseng S-H Grant A Durkin AJ In vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy J. Biomed. Opt. 2008 13 014016 10.1117/1.2829772 18315374 PMC2626348 sourceExperimental — accuracy not yet measured
Our copy of Tseng et al. (2008) is entirely about building a superficial diffusing DOS probe and recovering absorption/reduced-scattering coefficients of volar forearm and palm skin in 15 subjects (Introduction, Results Sec. 4, Conclusion); no passage mentions photoplethysmography, pulse/heart rate measurement, or any accuracy/error rate, and no 15% figure of that kind appears (searched: PPG/pulse rate/heart rate accuracy, pulse oximetry, introduction/motivation). The closest content is mechanistic background — Results Sec. 4 (Fig. 4a) that melanin absorption in dark skin reduces the probe's interrogation depth so hemoglobin features 'are not apparent,' and Sec. 4 (Fig. 5a) that dark-skinned subjects' absorption is ~5x Caucasian at 650 nm — which explains why light-based signals are weaker in dark skin but does not state the attributed quantitative claim about inaccurate PPG HR measurements. The paper also names no other work as the source of such a PPG error statistic, so misattribution cannot be established either. (LLM, conf=0.72)
- Not checked — no full text of the sourcecites [25] Fallow BA Tarumi T Tanaka H Influence of skin type and wavelength on light wave reflectance J. Clin. Monit. Comput. 2013 27 313 317 10.1007/s10877-013-9436-7 23397431 source
- Could not verifycites [26] Treesirichod A Chansakulporn S Wattanapan P Correlation between skin color evaluation by skin color scale chart and narrowband reflectance spectrophotometer Indian J. Dermatol. 2014 59 339 342 10.4103/0019-5154.135476 25071249 PMC4103266 sourceExperimental — accuracy not yet measured
The Introduction states that the study compares a skin-color chart with a narrowband reflectance spectrophotometer, and the Methods describe skin-color measurements with a Mexameter MX18. Searches for PPG heart-rate accuracy, dark-versus-light-skin error rates, and 15% found no passage addressing the cited claim. No page numbers were available in our copy. (LLM, conf=0.76)
- Not checked — no full text of the sourcecites [27] Ries AL Prewitt LM Johnson JJ Skin color and ear oximetry Chest 1989 96 287 290 10.1378/chest.96.2.287 2752811 source
- Could not verifycites [28] Lister T Wright PA Chappell PH Optical properties of human skin J. Biomed. Opt. 2012 17 0909011 10.1117/1.JBO.17.9.090901 23085902 sourceExperimental — accuracy not yet measured
Our copy of Lister et al. (2012) is a review of the absorption and scattering coefficients of human skin; it nowhere addresses photoplethysmography, heart-rate measurement, or any 15% error figure (searched: 'photoplethysmography PPG heart rate measurement accuracy dark skin', 'pulse oximetry blood volume pulse measurement error skin type', 'heart rate pulse oximetry photoplethysmogram ... Fitzpatrick'). The closest content is qualitative and mechanistic — Sec. 2.2 (Scattering) notes melanosome volume fraction rising from ~1% in pale to ~5% in darker skin and melanin's variable contribution to epidermal scatter, and Sec. 4.3 (Further Causes of Discrepancy) notes 'darker skin types demonstrating greater absorption across the visible spectrum' (Svaasand et al., only one or two subjects per skin type) — but neither reports PPG measurement accuracy nor the attributed magnitude. Nothing in our copy contradicts the claim; it simply does not cover it, so the 15% figure must come from another source. (LLM, conf=0.72)
- Not checked — no full text of the sourcecites [29] Weiler DT Villajuan SO Edkins L Cleary S Saleem JJ Wearable heart rate monitor technology accuracy in research: a comparative study between PPG and ECG technology Proc. Hum. Factors Ergon. Soc. Annu. Meet. 2017 61 1292 1296 10.1177/1541931213601804 source
- Could not verifycites [30] Nitzan M Romem A Koppel R Pulse oximetry: fundamentals and technology update Med. Devices Evid. Res. 2014 7 231 10.2147/MDER.S47319 PMC4099100 25031547 sourceExperimental — accuracy not yet measured
The 'Pulse oximetry – the technique' section says melanin can absorb light used in PPG, but it does not compare measurement accuracy by skin tone. The accuracy section concerns oxygen-saturation measurements, not PPG heart-rate errors. Searches for skin pigmentation, heart rate, and 15% found no passage supporting the claimed difference. (LLM, conf=0.76)
- Partly supportedcites [31] Yan, L., Hu, S., Alzahrani, A., Alharbi, S. & Blanos, P. A Multi-wavelength opto-electronic patch sensor to effectively detect physiological changes against human skin types. Biosensors7, 22 (2017). PMC5487964 28635643 sourceExperimental — accuracy not yet measured
The Introduction says skin pigmentation can affect PPG signal quality and mentions anecdotal errors of 3–5% in black skin. It does not report that inaccurate PPG heart-rate measurements occur 15% more frequently in dark skin than in light skin. The Discussion reports no significant effect of skin type on heart-rate measurements with the sensor tested (p = 0.09). (LLM, conf=0.87)
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“since optical HR measurements primarily measure green light absorption.24,25”
§ Investigating sources of inaccuracy in wearable optical heart rate sensors > Methods > Sample size
What the sources say
- Could not verifycites [24] Tseng S-H Grant A Durkin AJ In vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy J. Biomed. Opt. 2008 13 014016 10.1117/1.2829772 18315374 PMC2626348 sourceExperimental — accuracy not yet measured
Our copy of Tseng et al. (2008) deals exclusively with recovering skin absorption and reduced-scattering coefficients over the 650-1000 nm near-infrared window (Instrumentation, six laser diodes at 661-850 nm; Results, Sec. 4), and never mentions heart rate, pulse, photoplethysmography, or green-light absorption. Searches for 'green light absorption / heart rate / photoplethysmography' and for 'wavelengths shorter than 650 nm / hemoglobin spectral features' returned only the Conclusion's statement that the instrument is being improved so that shorter-than-650 nm wavelengths, with more prominent hemoglobin features, can be acquired - a forward-looking remark about their own DOS system, not a claim about how optical HR measurements work. Nothing in our copy either supports or contradicts the attributed point. (LLM, conf=0.72)
- Not checked — no full text of the sourcecites [25] Fallow BA Tarumi T Tanaka H Influence of skin type and wavelength on light wave reflectance J. Clin. Monit. Comput. 2013 27 313 317 10.1007/s10877-013-9436-7 23397431 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
41 more claims
Create a free account to see all 94 claims and to verify the 3 references still open.
- It may state two separate claims as one. 34
- Probably not a substantial claim. 17
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“too few people with the darkest skin tones were included (n = 9 in FST Type 6)”
From Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors (2021) · cites this paper as [1]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“A power analysis conducted prior to data collection indicated that a minimum of 52 participants would be needed to detect a medium effect size (f2(v) = 0.20) in a MANOVA with two groups and two dependent variables (absolute and directional error), assuming α = 0.05 and power (1 − β) = 0.80 [23].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [23]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“there are only a small handful of studies that examine skin tone and accuracy rates directly1–3,11”
From Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors (2021) · cites this paper as [1]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Bent et al. (2020) reported that PPG devices showed error rates exceeding 20% during cycling and resistance exercise in individuals with higher pigmentation, while maintaining <10% error at rest, underscoring the importance of activity context [5].”
From Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring (2025) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“failing to correct for these errors exacerbates existing healthcare disparities [10,23,24,25,26]”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [23]
Experimental — accuracy not yet measured
43 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185 · cited 1×
“In addition to HR, we examined HR variability (HRV), a clinically relevant diagnostic metric that can be derived from PPG signals and is a widely used metric of autonomic nervous system function.(43) The standard HRV metrics we examined, included the time-domain metrics, included mean HRV, minimum HRV, maximum HRV, RM…”
MethodThe validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · cited 1×
“Another suspected measurement error in wrist-worn devices is motion artifact, which is typically caused by displacement of the PPG sensor over the skin, changes in skin deformation, blood flow dynamics, and ambient temperature.(33,34) Motion artifacts may manifest as missing or false beats which result in incorrect HR…”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625 · cited 2×
“Our analyses reinforces the growing body of research demonstrating that wearable devices have higher error during activity than at rest.(8,11,35,38,39) We further demonstrate that the directionality of the HR error is dependent on the activity type.”
BackgroundResultGoldsack, J. C., Coravos, A., Bakker, J. P., Bent, B., Dowling, A. V., Fitzer-Attas, C., Godfrey, A., Godino, J. G., Gujar, N., Izmailova, E., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0260-4 · Cited by 557
Self-citationZonios, G., Bykowski, J., & Kollias, N. (2001) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2001.01577.x · Cited by 477
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
Research works printed but not linked: 1
- Hugh et al. Consumer-Grade Wrist-worn Ppg Sensors Can Be Used to Detect Differences in Heart Rate Variability among A Heterogenous Prediabetic Population (IEEE International Conference on Biomedical and Health Informatics, 2018).
Cited by
Items 101–200 of 661
Wearable Devices, Smartphones, and Interpretable Artificial Intelligence in Combating COVID-19
Hijazi, H., Abu Talib, M., Hasasneh, A., Bou Nassif, A., Ahmed, N., & Nasir, Q. (2021) · Sensors · doi:10.3390/s21248424 · Cited by 41
“In [39], the authors show no statistically significant difference in the accuracy of wearables (i.e., Apple, Fitbit, and Garmin) across skin types.”
BackgroundHehlmann, M. I., Schwartz, B., Lutz, T., Gómez Penedo, J. M., Rubel, J. A., & Lutz, W. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.613085 · Cited by 43
“(46) found accurate results for resting heart rate when investigating several devices, among others, the Garmin vivo smart.”
BackgroundHuhn, S., Matzke, I., Koch, M., Gunga, H., Maggioni, M. A., Sié, A., Boudo, V., Ouédraogo, W. A., Compaoré, G., Bunker, A., et al. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.972177 · Cited by 50
“More research is needed to understand the effect of skin pigmentation and its interference with measurements; some studies found no evidence (17, 20), while others did (21).”
BackgroundAnwer, S., Li, H., Antwi‐Afari, M. F., Mirza, A. M., Abdul-Rahman, M., Mehmood, I., Guo, R., & Wong, A. Y. L. (2023) · Journal of Construction Engineering and Management · doi:10.1061/jcemd4.coeng-13263 · Cited by 50
Photoplethysmography—new applications for an old technology: a sleep technology review
Ryals, S. M., Chiang, A. A.-P., Schutte-Rodin, S., Chandrakantan, A., Verma, N., Holfinger, S. J., Abbasi-Feinberg, F., Bandyopadhyay, A., Baron, K. G., Bhargava, S., et al. (2022) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10300 · Cited by 58
Stuyck, H., Costa, L. D., Cleeremans, A., & den Bussche, E. V. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2022.10.003 · Cited by 53
Navalta, J. W., Davis, D. W., Malek, E. M., Carrier, B., Bodell, N. G., Manning, J. W., Cowley, J. C., Funk, M. D., Lawrence, M. M., & DeBeliso, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-38329-w · Cited by 49
Heart rate detection by Fitbit ChargeHR™: A validation study versus portable polysomnography
Benedetti, D., Olcese, U., Frumento, P., Bazzani, A., Bruno, S., D’Ascanio, P., Maestri, M., Bonanni, E., & Faraguna, U. (2021) · Journal of Sleep Research · doi:10.1111/jsr.13346 · Cited by 38
Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms
Bae, S., Borac, S., Emre, Y., Wang, J., Wu, J., Kashyap, M., Kang, S., Chen, L., Moran, M., Cannon, J., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00102-x · Cited by 46
Milando, C. W., Black‐Ingersoll, F., Heidari, L., López-Hernández, I., de Lange, J., Negassa, A., McIntyre, A. M., Martinez, P. B., Bongiovanni, R., Levy, J. I., et al. (2022) · BMC Public Health · doi:10.1186/s12889-022-14692-7 · Cited by 38
“8 bpm during activity [27], and a slight underestimation of step counts, approximately 12.”
BackgroundAmzil, A., Abid, M., Hanini, M., Zaaloul, A., & Kafhali, S. E. (2024) · Cluster Computing · doi:10.1007/s10586-024-04285-x · Cited by 43
Detection and Monitoring of Viral Infections via Wearable Devices and Biometric Data
Goergen, C. J., Tweardy, M. J., Steinhubl, S. R., Wegerich, S., Singh, K., Mieloszyk, R. J., & Dunn, J. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-103020-040136 · Cited by 53
Self-citationSadeghi, M., McDonald, A. D., & Sasangohar, F. (2022) · PLoS ONE · doi:10.1371/journal.pone.0267749 · Cited by 54
“suitable for naturalistic data collection, like most wrist-based sensors, smart watches use optical technology the accuracy of which is affected by skin tone and proximity to skin (53).”
BackgroundWalk, talk, think, see and feel: harnessing the power of digital biomarkers in healthcare
Powell, D. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01023-w · Cited by 53
Evaluation of Wearable Electronics for Epilepsy: A Systematic Review
Rukasha, T., I Woolley, S., Kyriacou, T., & Collins, T. (2020) · Electronics · doi:10.3390/electronics9060968 · Cited by 38
Jia, S., Gao, H., Xue, Z., & Meng, X. (2022) · Biosensors · doi:10.3390/bios12111057 · Cited by 42
Bruno, E., Böttcher, S., Viana, P. F., Amengual‐Gual, M., Joseph, B., Epitashvili, N., Dümpelmann, M., Glasstetter, M., Biondi, A., Van Laerhoven, K., et al. (2021) · Epilepsia · doi:10.1111/epi.17044 · Cited by 37
“36 In our studies, only the Empatica E4 device was used at all of the four sites.”
MethodInvestigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches
Jiang, Y., Spies, C., Magin, J., Bhosai, S. J., Snyder, L., & Dunn, J. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000296 · Cited by 49
Self-citationSingh, S., Bennett, M. R., Chen, C., Shin, S., Ghanbari, H., & Nelson, B. W. (2024) · Journal of Medical Internet Research · doi:10.2196/62769 · Cited by 53
“Mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for the corresponding groups (Table 4 and Figures 5-7 [41,60-62]).”
InfluentialRamlakhan, S. L., Saatchi, R., Sabir, L., Singh, Y., Hughes, R., Shobayo, O., & Ventour, D. (2022) · Emergency Medicine Journal · doi:10.1136/emermed-2021-212068 · Cited by 44
Marvasti, T. B., Gao, Y., Murray, K. R., Hershman, S., McIntosh, C., & Moayedi, Y. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.07.009 · Cited by 35
“50 This raises the need for systematic validation of wearables under various conditions and across a wide range of skin tones before further integration of such devices in consumer products.”
BackgroundMach, S., Storozynski, P., Halama, J., & Krems, J. F. (2022) · Applied Ergonomics · doi:10.1016/j.apergo.2022.103855 · Cited by 44
Rom, Y., Aviv, R., Ianchulev, T., & Dvey-Aharon, Z. (2022) · BMJ Open Ophthalmology · doi:10.1136/bmjophth-2022-001140 · Cited by 34
The Importance of Data Quality Control in Using Fitbit Device Data From the Research Program
Lederer, L. E., Breton, A., Jeong, H., Master, H., Roghanizad, A. R., & Dunn, J. (2023) · JMIR mhealth and uhealth · doi:10.2196/45103 · Cited by 48
“…smartwatches found that darker skin tones positively correlated with increased heart rate error, whereas our study, in which we used more recent devices (2014-2018), did not find a relationship between heart rate measurement accuracy and skin tone across a subset of consumer smartwatches [18].”
InfluentialSelf-citationOffodile, A. C., Seitz, A. J., & Peterson, S. K. (2021) · JCO Clinical Cancer Informatics · doi:10.1200/cci.21.00111 · Cited by 35
“However, it is imperative to ensure the quality of these aforementioned devices and applications, as inaccuracies can negatively affect clinical decision making and patient outcomes.(4)”
BackgroundDudarev, V., Barral, O., Zhang, C., Davis, G., & Enns, J. T. (2023) · Sensors · doi:10.3390/s23135863 · Cited by 65
“This is consistent with multiple previous studies, including Bent et al. (2020), who reported higher reliability for measurements taken during rest, and reduced reliability with increased levels of activity.”
BackgroundMethodResultInfluentialHurwitz, E. G., Butzin-Dozier, Z., Master, H., O’Neil, S. T., Walden, A., Holko, M., Patel, R. C., & Haendel, M. A. (2024) · JMIR mhealth and uhealth · doi:10.2196/54622 · Cited by 45
“Previous studies have demonstrated that HR, steps, and activity measurements from Fitbit are fairly accurate and can be used for research purposes [36,37].”
BackgroundNachman, D., Constantini, K., Poris, G., Avraham, L. W., Gertz, S. D., Littman, R., Kabakov, E., Eisenkraft, A., & Gepner, Y. (2020) · Scientific Reports · doi:10.1038/s41598-020-74686-6 · Cited by 35
WristO2: Reliable Peripheral Oxygen Saturation Readings from Wrist-Worn Pulse Oximeters
Phillips, C., Liaqat, D., Gabel, M., & de Lara, E. (2021) · IEEE International Conference on Pervasive Computing and Communications Workshops (PerCom Workshops) · doi:10.1109/percomworkshops51409.2021.9430986 · Cited by 38
Berwal, D., Kuruba, A., Shaikh, A. M., Udupa, A., & Baghini, M. S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3170069 · Cited by 32
Helmer, P., Hottenrott, S., Rodemers, P., Leppich, R., Helwich, M., Pryss, R. C., Kranke, P., Meybohm, P., Winkler, B. E., & Sammeth, M. (2022) · Journal of Medical Internet Research · doi:10.2196/42359 · Cited by 40
“In particular, it has been shown that motion artifacts influence the mean absolute error (MAE) of the measurements by up to 30% [15].”
Deep Learning Fused Wearable Pressure and PPG Data for Accurate Heart Rate Monitoring
Mehrgardt, P., Khushi, M., Poon, S. K.-S., & Withana, A. I. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3123243 · Cited by 39
Self-Reported and Physiologic Reactions to Third BNT162b2 mRNA COVID-19 (Booster) Vaccine Dose
Mofaz, M., Yechezkel, M., Guan, G., Brandeau, M. L., Patalon, T., Gazit, S., Yamin, D., & Shmueli, E. (2022) · Emerging infectious diseases · doi:10.3201/eid2807.212330 · Cited by 31
“Nevertheless, recent studies show a considerably accurate heart rate measurement in the previous versions of the smartwatch used in this study (31,32).”
MethodAccuracy and Reliability of Pulse O2 Saturation Measured by a Wrist-worn Oximeter
Hermand, É., Coll, C., Richalet, J., & Lhuissier, F. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1337-2790 · Cited by 35
Manta, C. J., Mahadevan, N., Bakker, J. P., Irmak, S. O., Izmailova, E. S., Park, S., Poon, J. L., Shevade, S., Valentine, S., Vandendriessche, B., et al. (2021) · Digital Biomarkers · doi:10.1159/000515835 · Cited by 33
“Products from traditionally consumer-facing companies have been shown to take accurate measurements and a medical device designation does not render a product “fit for purpose” by default [35, 36].”
BackgroundDetecting sleep outside the clinic using wearable heart rate devices
Perez-Pozuelo, I., Posa, M., Spathis, D., Westgate, K. L., Wareham, N. J., Mascolo, C., Brage, S., & Palotti, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-11792-7 · Cited by 33
Promoting racial equity in digital health: applying a cross-disciplinary equity framework
Raza, M. M., Venkatesh, K. P., & Kvedar, J. C. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00747-5 · Cited by 37
Babu, A., Ranpariya, S., Sinha, D. K., Chatterjee, A., & Mandal, D. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202202021 · Cited by 33
Rehman, R. Z. U., Chatterjee, M., Manyakov, N. V., Daans, M., Jackson, A., O’Brisky, A., Telesky, T., Smets, S., Berghmans, P.-J., Yang, D., et al. (2024) · Sensors · doi:10.3390/s24216826 · Cited by 44
Assessment and management of adults with asthma during the covid-19 pandemic
Beaney, T. E., Salman, D., Samee, T., & Mak, V. (2020) · BMJ · doi:10.1136/bmj.m2092 · Cited by 31
Mishra, A., Baker-Eveleth, L. J., Gala, P., & Stachofsky, J. (2021) · Health Marketing Quarterly · doi:10.1080/07359683.2021.1994170 · Cited by 39
Textile‐Integrated Liquid Metal Electrodes for Electrophysiological Monitoring
Li, B. M., Reese, B. L., Ingram, K., Huddleston, M., Jenkins, M., Zaets, A., Reuter, M., Grogg, M. W., Nelson, M., Zhou, Y., et al. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202200745 · Cited by 29
3D‐Bioprinted Phantom with Human Skin Phototypes for Biomedical Optics
Yim, W., Zhou, J., Sasi, L., Zhao, J., Yeung, J., Cheng, Y., Jin, Z., Johnson, W., Xu, M., Palma‐Chavez, J., et al. (2022) · Advanced Materials · doi:10.1002/adma.202206385 · Cited by 39
Quality of Sleep Data Validation From the Xiaomi Mi Band 5 Against Polysomnography: Comparison Study
Concheiro-Moscoso, P., Groba, B., Álvarez-Estévez, D., Miranda-Duro, M. D. C., Pousada, T., Nieto-Riveiro, L., Mejuto-Muiño, F. J., & Pereira, J. (2023) · Journal of Medical Internet Research · doi:10.2196/42073 · Cited by 34
“Recently, some sleep researchers have considered these devices to be a potential complement to traditional sleep assessment methods because they can sense long-term variations in the circadian rhythm and sleep quantity and quality [4,25,26].”
InfluentialKim, C., Song, J. H., & Kim, S. H. (2023) · Annals of Rehabilitation Medicine · doi:10.5535/arm.23019 · Cited by 31
“According to previous research, PPG sensors show low accuracy of HR measurements with darker skin likely because darker skin with more melanin absorbs more green light than lighter skin [29].”
The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring
Hu, J., Park, D. Y., Agarwal, N., Herzig, M. S., Ormseth, G., Kaushik, M., Giao, D. M., Turkson‐Ocran, R., & Juraschek, S. P. (2023) · Current Cardiology Reports · doi:10.1007/s11886-023-01932-4 · Cited by 33
“…pho-toplethysmography to approximate BP can be confounded by the degree of melanin in patients with darker or tattooed skin, which absorbs more green light than lighter skin, leading to potential inaccuracies among patients with darker skin tones, especially in rooms with limited lighting [51, 52].”
BackgroundWearable Sensor-Based Detection of Influenza in Presymptomatic and Asymptomatic Individuals
Temple, D. S., Hegarty‐Craver, M., Furberg, R., Preble, E. A., Bergstrom, E., Gardener, Z., Dayananda, P., Taylor, L., Lemm, N., Papargyris, L., et al. (2022) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiac262 · Cited by 35
“Although optical sensors can provide data concordant with ECG, they are sensitive to wrist movement and skin tone differences that can introduce variation among healthy subjects [21, 22].”
BackgroundEffects of skin tone on photoacoustic imaging and oximetry
Else, T. R., Hacker, L., Gröhl, J., Bunce, E. V., Tao, R., & Bohndiek, S. E. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s1.s11506 · Cited by 50
“…in darker skin tones have been identified in several technologies where light passes through the skin before making a quantitative measurement, including pulse oximeters, 8 – 18 bilirubinometers, 19,20 wearable technologies, 21 – 24 cerebral oximeters, 25 and optical reflectance measurements.”
BackgroundPPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Lapsa, D., Janeliukštis, R., Metshein, M., & Selavo, L. (2024) · Applied Sciences · doi:10.3390/app14177451 · Cited by 37
Radin, J. M., Quer, G., Jalili, M., Hamideh, D., & Steinhubl, S. R. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00064-9 · Cited by 33
Shiwani, M. A., Chico, T., Ciravegna, F., & Mihaylova, L. S. (2023) · Sensors · doi:10.3390/s23125752 · Cited by 41
Optimizing sampling rate of wrist-worn optical sensors for physiologic monitoring
Bent, B., & Dunn, J. (2020) · Journal of Clinical and Translational Science · doi:10.1017/cts.2020.526 · Cited by 34
“This study is a retrospective analysis of a previously conducted study [17].”
ResultSelf-citationFeroz, A. S., Afzal, N., & Seto, E. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-056130 · Cited by 48
Pangal, D. J., Kugener, G., Zhu, Y., Sinha, A., Unadkat, V., Coté, D. J., Strickland, B. A., Rutkowski, M. J., Hung, A. J., Anandkumar, A., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-11549-2 · Cited by 30
The internet of medical things in healthcare management: a review
Ejiyi, C. J., Qin, Z., Ejiyi, M. B., Nneji, G. U., Monday, H. N., Agu, F. A., Ejiyi, T. U., Diokpo, C. N., & Orakwue, C. O. (2023) · Journal of Digital Health · doi:10.55976/jdh.22023116330-62 · Cited by 37
Bridging Gaps in Wearable Technology for Exercise and Health Professionals: A Brief Review
Schumann, M., & Doherty, C. (2024) · International Journal of Sports Medicine · doi:10.1055/a-2376-6332 · Cited by 26
“For example, it has previously been shown that optical sensors may provide accurate readings in rest - ing conditions but their accuracy reduces in exercise settings that are characterized by high-intensity body movements [34, 35].”
Bakker, J. P., Izmailova, E. S., Clement, A., Hoffmann, S., Leptak, C., Menetski, J. P., & Wagner, J. A. (2025) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.3398 · Cited by 26
Zhou, W., Chan, Y. E., Foo, C.-S., Zhang, J., Teo, J. X., Dávila, S., Huang, W., Yap, J. J. L., Cook, S. A., Tan, P. B. O., et al. (2022) · Journal of Medical Internet Research · doi:10.2196/34669 · Cited by 26
“We note that there are similarities between the wearable-derived resting heart rate and the clinical gold standard electrocardiogram-derived heart rate [4,40].”
Wearable Sensors for Healthcare of Industrial Workers: A Scoping Review
Moon, J., & Ju, B. (2024) · Electronics · doi:10.3390/electronics13193849 · Cited by 61
Guarducci, S., Jayousi, S., Caputo, S., & Mucchi, L. (2025) · Sensors · doi:10.3390/s25020556 · Cited by 36
“However, the device should not be worn too tightly, as this could constrict underlying vascular systems, potentially affecting blood flow and distorting the signal [84,94].”
Physiological responses to pain in cancer patients: A systematic review
Moscato, S., Cortelli, P., & Chiari, L. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106682 · Cited by 31
Timing errors and temporal uncertainty in clinical databases—A narrative review
Goodwin, A. J., Eytan, D., Dixon, W., Goodfellow, S. D., Doherty, Z. B., Greer, R. W., McEwan, A. L., Tracy, M. B., Laussen, P. C., Assadi, A., et al. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.932599 · Cited by 33
“Similarly, pulse oximetry is typically calculated as a moving average, introducing a delay with a magnitude related to the size of the averaging window (107–109).”
BackgroundOptical Integration in Wearable, Implantable and Swallowable Healthcare Devices
Yi, L., Hou, B., & Liu, X. (2023) · ACS Nano · doi:10.1021/acsnano.3c04284 · Cited by 27
Shetty, A., Delanerolle, G., Zeng, Y., Shi, J. Q., Ebrahim, R., Pang, J. T., Hapangama, D. K., Sillem, M., Shetty, S., Shetty, B., et al. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.850601 · Cited by 28
Beyond Skin Tone: A Multidimensional Measure of Apparent Skin Color
Thong, W. E., Joniak, P., & Xiang, A. (2023) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51070.2023.00452 · Cited by 51
“This has an impact on real-life applications, as models can produce wrong skin lesion diagnostics [15] or incorrect heart rate measurements [5, 27, 62] for individuals with darker skin tones.”
BackgroundAn evaluation of heart rate monitoring with in-ear microphones under motion
Butkow, K.-J., Dang, T., Ferlini, A., Ma, D., Liu, Y., & Mascolo, C. (2024) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2024.101913 · Cited by 40
Identifying key quality features for wearable technology embedded products using the Kano model
Salahuddin, M., & Lee, Y. (2020) · International Journal of Clothing Science and Technology · doi:10.1108/ijcst-08-2019-0130 · Cited by 27
Bartels, S. L., Johnsson, S. I., Boersma, K., Flink, I., McCracken, L. M., Petersson, S., Christie, H. L., Feldman, I., Simons, L. E., Onghena, P., et al. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-059152 · Cited by 23
Nelson, B. W., Flannery, J., Flournoy, J. C., Duell, N., Prinstein, M. J., & Telzer, E. H. (2021) · Journal of Child Psychology and Psychiatry · doi:10.1111/jcpp.13471 · Cited by 22
Lee, K. F. A., Gan, W., & Christopoulos, G. I. (2021) · Sensors · doi:10.3390/s21113843 · Cited by 27
Skin tone, confidence, and data quality of heart rate sensing in WearOS smartwatches
Ray, I., Liaqat, D., Gabel, M., & de Lara, E. (2021) · 2021 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) · doi:10.1109/percomworkshops51409.2021.9431120 · Cited by 23
“[21] (our MAE is slightly lower since our study protocol includes plenty of rest before measurement resulting in lower HR).”
BackgroundBöttcher, S., Bruno, E., Epitashvili, N., Dümpelmann, M., Zabler, N., Glasstetter, M., Ticcinelli, V., Thorpe, S., Lees, S., Van Laerhoven, K., et al. (2022) · Sensors · doi:10.3390/s22093318 · Cited by 23
A Clinician’s Guide to Smartwatch “Interrogation”
Gupta, S. K., Mahmoud, A., & Massoomi, M. R. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01718-0 · Cited by 25
Matzke, I., Huhn, S., Koch, M., Maggioni, M. A., Munga, S., Muma, J. O., Odhiambo, C. O., Kwaro, D., Obor, D., Bärnighausen, T., et al. (2024) · JMIR mhealth and uhealth · doi:10.2196/54669 · Cited by 23
“…studies have noted a correlation between the Fitz-Patrick skin scale and heart rate measurements via photoplethysmography, suggesting reduced heart rate measurement accuracy in individuals with higher Fitz-Patrick scale values [40,42], although some studies [43] did not find this correlation.”
BackgroundMontanari, A., Ferlini, A., Balaji, A. N., Mascolo, C., & Kawsar, F. (2023) · Scientific Data · doi:10.1038/s41597-023-02762-3 · Cited by 41
“Skin tone is an additional factor that could affect data quality 35 .”
BackgroundMethodImplications of Bias in Artificial Intelligence: Considerations for Cardiovascular Imaging
van Assen, M., Beecy, A., Gershon, G., Newsome, J. M., Trivedi, H., & Gichoya, J. W. (2024) · Current Atherosclerosis Reports · doi:10.1007/s11883-024-01190-x · Cited by 28
Schweizer, T., & Gilgen-Ammann, R. (2025) · JMIR Cardio · doi:10.2196/67110 · Cited by 36
“Similarly, one study found that the magnitude of the errors depended on the activity type and that it can result in an absolute error that is 30% higher than at rest [38].”
Selecting Mobile Health Technologies for Electronic Health Record Integration: Case Study
Shaw, R. J., Stroo, M., Fiander, C., & McMillan, K. (2020) · Journal of Medical Internet Research · doi:10.2196/23314 · Cited by 25
“While this has been addressed by many device manufacturers [13], it is a lesson in the importance of ensuring devices are usable across a variety of patient populations.”
BackgroundGanti, V. G., Carek, A. M., Jung, H., Srivatsa, A. V., Cherry, D., Johnson, L. N., & Inan, O. T. (2021) · JMIR mhealth and uhealth · doi:10.2196/27466 · Cited by 25
“Although even green wavelength PPGs have demonstrated the ability to reliably extract heart rate across a wide variety of skin tones [48], our data suggest that these shorter wavelengths cannot be used to dependably compute the PTT in a diverse population.”
BackgroundWearable Pulse Oximeter for Swimming Pool Safety
Kałamajska, E., Misiurewicz, J., & Weremczuk, J. (2022) · Sensors · doi:10.3390/s22103823 · Cited by 22
“There will be differences for people with different skin tones or different amounts of muscle tissue [23].”
BackgroundDuarah, R., Torné‐Morató, H., Zhang, G., Amin, Y., Pabast, M., Sharma, N., He, S., Das, M. R., & Pompa, P. P. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202504419 · Cited by 24
HRS White Paper on Clinical Utilization of Digital Health Technology
Wan, E. Y., Ghanbari, H., AKOUM, N. W., Attia, Z. I., Asirvatham, S. J., Chung, E. H., Dagher, L., Al‐Khatib, S. M., Mendenhall, G. S., McManus, D. D., et al. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2021.07.001 · Cited by 22
“On the other hand, testing the accuracy of PPG devices in different real-life settings has unveiled several sources of inaccuracy.(38,40) Darker skin tones absorb more green light than lighter ones, interfering with PPG-based mechanisms and decreasing the accuracy of PPG-based devices in measuring heart rate.”
BackgroundResultInfluentialDevine, J. K., Schwartz, L. P., & Hursh, S. R. (2022) · Sensors · doi:10.3390/s22072731 · Cited by 25
Chapman, B. P., Gullapalli, B. T., Rahman, T., Smelson, D. A., Boyer, E. W., & Carreiro, S. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00664-z · Cited by 29
Chatterjee, T., Ghosh, A., & Sarkar, S. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871494 · Cited by 25
“The presence of artifacts causes alarm fatigue, signal loss, and inaccurate measurements and improper diagnoses [2-15].”
BackgroundHigher sensitivity monitoring of reactions to COVID-19 vaccination using smartwatches
Guan, G., Mofaz, M., Qian, G. L., Patalon, T., Shmueli, E., Yamin, D., & Brandeau, M. L. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00683-w · Cited by 25
Alfonso, C., Garcia-Gonzalez, M. A., Parrado, E., Gil-Rojas, J., Ramos-Castro, J. J., & Capdevila, L. (2022) · Scientific Reports · doi:10.1038/s41598-022-18356-9 · Cited by 30
Heart Rate Variability in Adults With Substance Use Disorder: A Comprehensive Narrative Review
Moon, S. J. E., Schlenk, E. A., & Lee, H. (2023) · Journal of the American Psychiatric Nurses Association · doi:10.1177/10783903221145142 · Cited by 28
“With growing evidence of the good reliability of non-ECG devices in measuring HRV (Bent et al., 2020; Hsiao et al., 2017), using wearables may be a simple and practical approach to continuously monitor and observe for changes in HRV over time.”
BackgroundGlasstetter, M., Böttcher, S., Zabler, N., Epitashvili, N., Dümpelmann, M., Richardson, M. P., & Schulze-Bonhage, A. (2021) · Sensors · doi:10.3390/s21186017 · Cited by 21
Validity of heart rate measurements in wrist-based monitors across skin tones during exercise
Hung, S. H., Serwa, K., Rosenthal, G., & Eng, J. J. (2025) · PLOS ONE · doi:10.1371/journal.pone.0318724 · Cited by 21
Birla, M., Rajan, Roy, P. G., Gupta, I., & Malik, P. S. (2024) · Oncology · doi:10.1159/000540494 · Cited by 20
“Physiological signals captured by wearables are highly susceptible to motion distortions and outside noise, which should be mitigated before [45].”
Neitzel, R. L., Smith, L., Wang, L., Green, G. E., Block, J., Carchia, M., Mazur, K., DePalma, G., Azimi, R., & Villanueva, B. (2022) · The Journal of the Acoustical Society of America · doi:10.1121/10.0009620 · Cited by 23
Comparison of Apple Watch vs KardiaMobile: A Tale of Two Devices
Lee, C., Lee, C., Fernando, C., & Chow, C.-M. (2022) · CJC Open · doi:10.1016/j.cjco.2022.07.011 · Cited by 22
“Lastly, PPG has been found to have greater inaccuracy for users with darker skin tones.(22) An examination of patient demographic factors revealed that gender and age influenced device accuracy.”
BackgroundThe relationship between wearable-derived sleep features and relapse in Major Depressive Disorder
Matcham, F., Carr, E., Meyer, N., White, K. M., Oetzmann, C., Leightley, D., Lamers, F., Siddi, S., Cummins, N., Annas, P., et al. (2024) · Journal of Affective Disorders · doi:10.1016/j.jad.2024.07.136 · Cited by 33
“Darker skin tones absorb more green light and, therefore, reduce the accuracy of heart rate estimation, which is used in sleep/wake classification (Bent et al., 2020).”
Artificial Intelligence in Endurance Sports: Metabolic, Recovery, and Nutritional Perspectives
Grivas, G. V., & Safari, K. (2025) · Nutrients · doi:10.3390/nu17203209 · Cited by 34
“Sensor-derived metrics can be affected by external noise, including movement artifacts, device placement, or skin characteristics [65].”
Xie, Y., & Tummala, S. P. (2025) · Sensors · doi:10.3390/s25237294 · Cited by 38
Puranen, A., Halkola, T., Kirkeby, O., & Vehkaoja, A. T. (2020) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47125.2020.9278523 · Cited by 27
“They did not find statistically significant difference in HR estimation accuracy between skin tones [7].”
BackgroundMissing data imputation techniques for wireless continuous vital signs monitoring
van Rossum, M., da Silva, P. M. A., Wang, Y., Kouwenhoven, E. A., & Hermens, H. J. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-00975-w · Cited by 21
“Measurement disturbances or disruptions are often caused by motion artefacts, which occur frequently during continuous wireless measurements in mobilizing patients [12, 13].”
Zhu, H., Yu, H., Zhang, J., Zhang, Y., Zhang, L., Liu, S., & Xie, W. (2024) · Laser & Photonics Review · doi:10.1002/lpor.202400042 · Cited by 19
Tanade, C., Khan, N. S., Rakestraw, E., Ladd, W., Draeger, E. W., & Randles, A. P. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01216-3 · Cited by 23
“Issuessuchas motionartefacts,signalcrossover,andgapsinrecording(suchasdueto charging)havebeenexploredin 68 – 70 and will need to be explicitly accounted for before clinical translation.”
Metadata
- Authors
- Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P.
- Affiliations
- Duke University (US)
- Corresponding author
- Dunn, Jessilyn P.
- Venue
- npj Digital Medicine
- Published
- 2020-02-10
- Volume
- 3
- Issue
- 1
- Pages
- 18-18
- ISSN
- 2398-6352 (ISSN-L)
- PMC
- PMC7010823
- OpenAlex
- W3005348902
- Cited by
- 673
- References
- 37
- Citations by year
- 2026: 127 · 2025: 114 · 2024: 111 · 2023: 98 · 2022: 114 · 2021: 85 · 2020: 24
- FWCI
- 25.20
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- npj Digital Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Duke FORGE Fellowship
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- wearable devices, heart rate monitoring, photoplethysmography, measurement accuracy, skin tone, motion artifacts, device comparison, physical activity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.