The DOI matches its Crossref record; 125 of the 125 references it cites were found in a registry or an index.
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Open accessAbstract
PURPOSE OF REVIEW: When an individual loses a limb, he/she loses touch with the world and with the people around him/her. Somatosensation is critical to the feeling of connection and control of one's own body. Decades of attempts to replace lost somatosensation by sensory substitutions have been ineffective outside of the laboratory. This review discusses important recent results demonstrating chronic somatosensory restoration through direct peripheral nerve stimulation. RECENT FINDINGS: Stimulation of peripheral nerves results in somatosensory perception on the phantom limb. Sensations are localized to several independent and functionally relevant locations, such as the fingertips, thenar eminence, ulnar border and dorsal surface. Patterns in stimulation intensity change the perception experience by the user, opening new dimensions on neuromodulation. SUMMARY: Neural interfaces with sophisticated stimulation paradigms create a user's perception of his/her hand to touch and manipulate objects. The pattern of intensity and frequency of stimulation is critical to the quality and intensity of perceived sensation. Restoring feeling has allowed the individuals to, 'feel [my] hand for the first time since the accident,' and 'feel [my] wife touch my hand'. Individuals using a prosthetic hand with sensation can pull cherries and grapes from the stem, open water bottles and move objects without destroying these objects - all while audio and visually deprived. After regaining sensation, phantom pain is eliminated in individuals that had frequent, sometimes debilitating, pain following limb loss. With over 5 subject-years of experience, this work is leading the evolution of a new era in prostheses. Somatosensory prosthetics as a standard procedure to augment and restore somatosensation are now within our reach.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Spikes are responsible for conveying information in the axons of a nerve, and the spike rate or frequency is involved in transmitting sensorimotor commands in a single axon (Tyler, 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tyler, 2015
In the citing paper
“Optimization of sensory feedback can provide better results, which include the restoration of a sense of touch that allows amputees to experience the world in a natural way and that also helps in allowing the bionic arm/prosthesis to be incorporated into their body image (Tyler, 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tyler, 2015
In the citing paper
“Bensmaia (2015) and Tyler (2015) concluded that many challenges are ahead before selective activation of all receptors.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tyler (2015)
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Proske, U., & Gandevia, S. C. (2012) · Physiological Reviews · doi:10.1152/physrev.00048.2011 · Cited by 2,223
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Upper limb prosthesis use and abandonment
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics and Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,123
My body in the brain: A neurocognitive model of body-ownership.
Tsakiris, M. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2009.09.034 · Cited by 1,069
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
What is embodiment? A psychometric approach
Longo, M. R., Schüür, F., Kammers, M. P. M., Tsakiris, M., & Haggard, P. (2008) · Cognition · doi:10.1016/j.cognition.2007.12.004 · Cited by 956
Mechanisms of sensory transduction in the skin
Lumpkin, E. A., & Caterina, M. J. (2007) · Nature · doi:10.1038/nature05662 · Cited by 860
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“There are several options being explored for peripheral nerve interfaces [84,85].”
BackgroundMcCloskey, D. I. (1978) · Physiological Reviews · doi:10.1152/physrev.1978.58.4.763 · Cited by 828
Wolff, P., & Barbey, A. K. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00001 · Cited by 788
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Self-citationGroves, D. A., & Brown, V. J. (2005) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2005.01.004 · Cited by 677
Biddiss, E. A., & Chau, T. T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 647
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Embodiment, ownership and disownership
de Vignemont, F. (2010) · Consciousness and Cognition · doi:10.1016/j.concog.2010.09.004 · Cited by 509
Phantom pain and phantom sensations in upper limb amputees: an epidemiological study
Kooijman, C. M., Dijkstra, P. U., Geertzen, J. H. B., Elzinga, A., & van der Schans, C. P. (2000) · Pain · doi:10.1016/s0304-3959(00)00264-5 · Cited by 501
Proprioception and locomotor disorders
Dietz, V. H. (2002) · Nature reviews. Neuroscience · doi:10.1038/nrn939 · Cited by 498
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
McGlone, F. P., & Reilly, D. M. (2009) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.08.004 · Cited by 470
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 4×
“Implant of TIME intrafascicular electrodes for 4 weeks.”
BackgroundInfluentialLongitudinal Change in CSF Biomarkers in Autosomal-Dominant Alzheimer’s Disease
Fagan, A. M., Xiong, C., Jasielec, M. S., Bateman, R. J., Goate, A. M., Benzinger, T. L. S., Ghetti, B., Martins, R. N., Masters, C. L., Mayeux, R., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3007901 · Cited by 434
Proske, U., & Gandevia, S. C. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.175372 · Cited by 423
Cutaneous Receptors Contribute to Kinesthesia at the Index Finger, Elbow, and Knee
Collins, D. F., Refshauge, K. M., Todd, G., & Gandevia, S. C. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00191.2005 · Cited by 416
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 4×
“The Flat Interface Nerve Electrode (FINE) [91] has shown fascicular level selectivity for stimulation [91–93] and recording capabilities [94].”
BackgroundInfluentialSelf-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Phantom pain is associated with preserved structure and function in the former hand area
Makin, T. R., Scholz, J., Filippini, N., Slater, D. H., Tracey, I., & Johansen‐Berg, H. (2013) · Nature Communications · doi:10.1038/ncomms2571 · Cited by 349
The body in the mind: On the relationship between interoception and embodiment
Herbert, B. M., & Pollatos, O. (2012) · Topics in Cognitive Science · doi:10.1111/j.1756-8765.2012.01189.x · Cited by 338
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Peripheral nervous system origin of phantom limb pain
Vaso, A., Adahan, H., Gjika, A., Zahaj, S., Zhurda, T., Vyshka, G., & Devor, M. G. (2014) · Pain · doi:10.1016/j.pain.2014.04.018 · Cited by 297
Advanced Upper Limb Prosthetic Devices: Implications for Upper Limb Prosthetic Rehabilitation
Resnik, L., Meucci, M. R., Lieberman-Klinger, S., Fantini, C., Kelty, D. L., Disla, R., & Sasson, N. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.11.010 · Cited by 280
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Risk Factors for Continued Opioid Use One to Two Months After Surgery for Musculoskeletal Trauma
Helmerhorst, G. T. T., Vranceanu, A., Vrahas, M. S., Smith, M., & Ring, D. (2014) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.l.01406 · Cited by 251
The experience of agency in human-computer interactions: a review
Limerick, H., Coyle, D., & Moore, J. W. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00643 · Cited by 241
Mechanisms underlying embodiment, disembodiment and loss of embodiment
Giummarra, M. J., Gibson, S. J., Georgiou‐Karistianis, N., & Bradshaw, J. L. (2007) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2007.07.001 · Cited by 235
Central mechanisms in phantom limb perception: The past, present and future
Giummarra, M. J., Gibson, S. J., Georgiou‐Karistianis, N., & Bradshaw, J. L. (2007) · Brain Research Reviews · doi:10.1016/j.brainresrev.2007.01.009 · Cited by 234
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
Differences in myoelectric and body-powered upper-limb prostheses: systematic literature review
Carey, S. L., Lura, D. J., Highsmith, M. J., CP, & FAAOP (2015) · Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.08.0192 · Cited by 227
Selective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222
Do congenital prosopagnosia and the other-race effect affect the same face recognition mechanisms?
Esins, J., Schultz, J., Wallraven, C., & lthoff, I. B. ⁄. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00759 · Cited by 212
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Anxiety and depression following traumatic limb amputation: A systematic review
Mckechnie, P. S., & John, A. M. (2014) · Injury · doi:10.1016/j.injury.2014.09.015 · Cited by 190
Sensory Dysfunction Following Stroke: Incidence, Significance, Examination, and Intervention
Sullivan, J. E., & Hedman, L. D. (2008) · Topics in Stroke Rehabilitation · doi:10.1310/tsr1503-200 · Cited by 185
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
Systematic review of the effectiveness of mirror therapy in upper extremity function
Ezendam, D., Bongers, R. M., & Jannink, M. J. A. (2009) · Disability and Rehabilitation · doi:10.3109/09638280902887768 · Cited by 185
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Self-citationModeling axon membranes for functional electrical stimulation
Rattay, F., & Aberham, M. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250575 · Cited by 174
Energy-efficient waveform shapes for neural stimulation revealed with a genetic algorithm
Wongsarnpigoon, A., & Grill, W. M. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046009 · Cited by 166
Predictors for return to work in patients with median and ulnar nerve injuries
Bruyns, C. N. P., Jaquet, J.-B., Schreuders, T. A. R., Kalmijn, S., Kuypers, P. D. L., & Hovius, S. E. R. (2003) · The Journal Of Hand Surgery · doi:10.1053/jhsu.2003.50026 · Cited by 165
A Miniature Vibrotactile Sensory Substitution Device for Multifingered Hand Prosthetics
Cipriani, C., D’Alonzo, M., & Carrozza, M. C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2173342 · Cited by 164
Clay, F. J., Newstead, S., & McClure, R. (2010) · Injury · doi:10.1016/j.injury.2010.04.005 · Cited by 163
Saradjian, A., Thompson, A. R., & Datta, D. (2008) · Disability and Rehabilitation · doi:10.1080/09638280701427386 · Cited by 152
Tactile sensory substitution: Models for enaction in HCI
Visell, Y. (2008) · Interacting with Computers · doi:10.1016/j.intcom.2008.08.004 · Cited by 148
Wark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148
Schiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148
Self-citationWheeler, J. W., Bark, K., Savall, J., & Cutkosky, M. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039602 · Cited by 146
Fascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · cited 1×
“There is a stochastic distribution of Nodes of Ranvier and axon sizes that results in a distributed recruitment within the nerve limiting the maximum effective electrode density [102,103].”
BackgroundSelf-citationVincent, H. K., Horodyski, M., Vincent, K. R., Brisbane, S. T., & Sadasivan, K. K. (2015) · PM&R · doi:10.1016/j.pmrj.2015.03.007 · Cited by 145
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
Self-citationThe foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Bailey, R. R., Kaskutas, V. K., Fox, I. K., Baum, C. M., & Mackinnon, S. E. (2009) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2009.07.002 · Cited by 132
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
Self-citationSensitivity and selectivity of intraneural stimulation using a silicon electrode array
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76386 · Cited by 130
Mechanism-based treatment in complex regional pain syndromes
Gierthmühlen, J., Binder, A., & Baron, R. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.140 · Cited by 125
Sensory capacity of reinnervated skin after redirection of amputated upper limb nerves to the chest
Marasco, P. D., Schultz, A. E., & Kuiken, T. A. (2009) · Brain · doi:10.1093/brain/awp082 · Cited by 113
Desmond, D. M., & MacLachlan, M. (2006) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2005.08.014 · Cited by 112
Gaunt, R. A., Procházka, A., Mushahwar, V. K., Guevremont, L., & ELLAWAY, P. H. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00061.2006 · Cited by 110
Inversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · cited 1×
“Two examples include the Slowly Penetrating Interfascicular Nerve Electrode [95] and the grove electrode [96].”
BackgroundSelf-citationYoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
Weber, D. J., London, B. M., Hokanson, J., Ayers, C. A., Gaunt, R. A., Torres, R. R., Zaaimi, B., & Miller, L. E. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163145 · Cited by 104
Desmond, D. M., & MacLachlan, M. (2010) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0b013e328336388d · Cited by 100
A Psychiatric Study of Amputees
Shukla, G. D., Sahu, S. C., Tripathi, R. P., & Gupta, D. K. (1982) · The British Journal of Psychiatry · doi:10.1192/bjp.141.1.50 · Cited by 100
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
Brunner, E., De Herdt, A., Minguet, P., Baldew, S.-S., & Probst, M. (2013) · Disability and Rehabilitation · doi:10.3109/09638288.2012.683848 · Cited by 96
Motor deficits in patients with large-fiber sensory neuropathy.
Sanes, J. N., Mauritz, K.-H., Evarts, E. V., Dalakas, M. C., & Chu, A. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.3.979 · Cited by 95
Sensory control of target acquisition
Cordo, P. J., & Flanders, M. (1989) · Trends in Neurosciences · doi:10.1016/0166-2236(89)90167-7 · Cited by 94
Functional comparison of upper extremity amputees using myoelectric and conventional prostheses.
Stein, R. B., & Walley, M. (1983) · PubMed · Cited by 92
Fisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89
Self-citation(1974) · PubMed · Cited by 89
SENSORY SUBSTITUTION IN PROSTHETICS
Lundborg, G., & Rosén, B. (2001) · Hand Clinics · doi:10.1016/s0749-0712(21)00526-6 · Cited by 81
The neural encoding of self-motion
Cullen, K. E. (2011) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2011.05.022 · Cited by 80
Psychiatric and Emotional Sequelae of Surgical Amputation
Cavanagh, S. R., Shin, L. M., Karamouz, N., & Rauch, S. L. (2006) · Psychosomatics · doi:10.1176/appi.psy.47.6.459 · Cited by 74
Contributions of skin and muscle afferent input to movement sense in the human hand
Cordo, P. J., Horn, J.-L., Künster, D., Cherry, A. B. C., Bratt, A. K., & Gurfinkel, V. S. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00201.2010 · Cited by 73
Psychosocial Issues after a Traumatic Hand Injury: Facilitating Adjustment
Hannah, S. D. (2011) · Journal of Hand Therapy · doi:10.1016/j.jht.2010.11.001 · Cited by 72
Wolff, A. P., Vanduynhoven, E., van Kleef, M., Huygen, F. J. P. M., Pope, J. E., & Mekhail, N. A. (2011) · Pain Practice · doi:10.1111/j.1533-2500.2011.00454.x · Cited by 70
Identifying the role of proprioception in upper-limb prosthesis control
Blank, A. A., Okamura, A. M., & Kuchenbecker, K. J. (2008) · ACM Transactions on Applied Perception · doi:10.1145/1773965.1773966 · Cited by 66
Vibrotactile Sensory Substitution Elicits Feeling of Ownership of an Alien Hand
D’Alonzo, M., & Cipriani, C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050756 · Cited by 63
Comparison of upper limb amputees and lower limb amputees: a psychosocial perspective
Desteli, E. E., İmren, Y., Erdoğan, M., Sarísoy, G., & Coşgun, S. (2014) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-014-0418-3 · Cited by 61
Vibrotactile Sensory Substitution for Electromyographic Control of Object Manipulation
Rombokas, E., Stepp, C. E., Chang, C., Malhotra, M., & Matsuoka, Y. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2252174 · Cited by 61
Sexuality and amputation: a systematic literature review
Geertzen, J. H. B., Es, C. G. V., & Dijkstra, P. U. (2009) · Disability and Rehabilitation · doi:10.1080/09638280802240589 · Cited by 57
Schiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57
Self-citationRecruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56
Afferent Sensory Feedback for Lower Extremity Prosthesis
Clippinger, F. W., Seaber, A. V., McElhaney, J. H., Harrelson, J. M., & Maxwell, G. M. (1982) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198209000-00031 · Cited by 55
Predicting Any Arm Movement Feedback to Induce Three-Dimensional Illusory Movements in Humans
Thyrion, C., & Roll, J. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00025.2010 · Cited by 54
Weber, D. J., Stein, R. B., Everaert, D. G., & Procházka, A. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875575 · Cited by 54
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Self-citationNeural correlates of the rubber hand illusion in amputees: A report of two cases
Schmalzl, L., Kalckert, A., Ragnö, C., & Ehrsson, H. H. (2013) · Neurocase · doi:10.1080/13554794.2013.791861 · Cited by 52
Cheung, E., Alvaro, R., & Colotla, V. A. (2003) · Rehabilitation Psychology · doi:10.1037/0090-5550.48.2.109 · Cited by 49
Poor motor function is associated with reduced sensory processing after stroke
Campfens, S. F., Zandvliet, S. B., Meskers, C. G. M., Schouten, A. C., van Putten, M. J. A. M., & van der Kooij, H. (2015) · Experimental Brain Research · doi:10.1007/s00221-015-4206-z · Cited by 46
Updates in Targeted Sensory Reinnervation for Upper Limb Amputation
Hebert, J. S., Elzinga, K. E., Chan, K. M., Olson, J. L., & Morhart, M. J. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0045-7 · Cited by 44
Acute stress disorder and post-traumatic stress disorder following traumatic amputation.
Çopuroğlu, C., Özcan, M., Yılmaz, B., Görgülü, Y., Abay, E., & Yalnız, E. (2010) · PubMed · Cited by 41
Thota, A. K., Kuntaegowdanahalli, S., Starosciak, A. K., Abbas, J. J., Orbay, J., Horch, K. W., & Jung, R. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.020 · Cited by 41
On the right (and left) track: Twenty years of progress in studying hemispatial neglect
Buxbaum, L. J. (2005) · Cognitive Neuropsychology · doi:10.1080/02643290500202698 · Cited by 38
Sexuality in persons with limb amputation: A meaningful discussion of re-integration
Ide, M. (2004) · Disability and Rehabilitation · doi:10.1080/09638280410001708977 · Cited by 36
Hellman, R. B., Chang, E. T., Tanner, J., Tillery, S. I. H., & Santos, V. J. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00026 · Cited by 35
Sensory feedback for upper limb prostheses
Hsiao, S. S., Fettiplace, M. R., & Darbandi, B. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53355-5.00005-1 · Cited by 34
Degraded EEG decoding of wrist movements in absence of kinaesthetic feedback
Galán, F., Baker, M. R., Alter, K., & Baker, S. N. (2014) · Human Brain Mapping · doi:10.1002/hbm.22653 · Cited by 30
Berning, K., Cohick, S., Johnson, R. E., Miller, L. A., CP, & Sensinger, J. W. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2013.05.0123 · Cited by 30
Energy-optimal electrical-stimulation pulses shaped by the least-action principle
Krouchev, N. I., Danner, S. M., Vinet, A., Rattay, F., & Sawan, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090480 · Cited by 29
Doğu, B., Kuran, B., Şirzai, H., Sağ, S., Akkaya, N., & Şahin, F. (2013) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0000000000000040 · Cited by 29
Galanakos, S., Bot, A. G., Zoubos, A., & Soucacos, P. (2013) · Journal of reconstructive microsurgery · doi:10.1055/s-0033-1361838 · Cited by 27
Association of Temperature and Humidity with Trauma Deaths
Kalankesh, L. R., Mansouri, F., & Khanjani, N. (2015) · Trauma Monthly · doi:10.5812/traumamon.23403 · Cited by 26
Optimizing nerve cuff stimulation of targeted regions through use of genetic algorithms
Brill, N., & Tyler, D. J. (2011) · doi:10.1109/iembs.2011.6091438 · Cited by 24
Self-citationA phenomenological approach to psychoprosthetics
Mills, F. B. (2012) · Disability and Rehabilitation · doi:10.3109/09638288.2012.708819 · Cited by 17
Improving the management of patients at risk of haemorrhagic stroke
Kingwell, K. (2013) · Nature Reviews Neurology · doi:10.1038/nrneurol.2013.257 · Cited by 16
Quality of Life of Caregiver Spouses of Veterans With Bilateral Lower Extremity Amputations
Moradi, A., Ebrahimzadeh, M. A., & Soroush, M. R. (2015) · Trauma Monthly · doi:10.5812/traumamon.21891 · Cited by 15
Cited by
Sorted by citations
Valle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 355
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationThe neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258
Self-citationNeurocognitive barriers to the embodiment of technology
Makin, T. R., de Vignemont, F., & Faisal, A. A. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0014 · Cited by 165
Barbin, J., Seetha, V., Casillas, J.-M., Paysant, J., & Pérennou, D. A. (2016) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2016.04.001 · Cited by 158
Metadata
- Authors
- Tyler, D. J.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Tyler, Dustin J.
- ORCID
- Tyler, Dustin J.
- Venue
- Current Opinion in Neurology
- Published
- 2015-12
- Volume
- 28
- Issue
- 6
- Pages
- 574-581
- ISSN
- 1350-7540 (ISSN-L)
- PMC
- PMC5517303
- OpenAlex
- W2415521922
- Cited by
- 105
- References
- 125
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 3 · 2023: 15 · 2022: 10 · 2021: 9 · 2020: 10 · 2019: 17 · 2018: 10 · 2017: 14 · 2016: 2
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Current Opinion in Neurology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (I01 RX001334)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- neural interfaces, somatosensory feedback, peripheral nerve stimulation, phantom limb, sensory substitution, prosthetic hand, phantom pain, neuromodulation, limb loss
- MeSH terms
- Artificial Limbs, Electric Stimulation, Hand, Humans, Peripheral Nerves, Touch, Touch Perception, Feedback, Sensory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review