The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Will Retinal Implants Restore Vision?
Abstract
A number of research groups are developing electrical implants that can be attached directly to the retina in an attempt to restore vision to patients suffering from retinal degeneration. However, despite promising results in animal experiments, there are still several major obstacles to overcome before retinal prostheses can be used clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Preservation of the Inner Retina in Retinitis Pigmentosa: A Morphometric Analysis
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 643
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 601
Pattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592
Artificial Vision for the Blind by Connecting a Television Camera to the Visual Cortex
Dobelle, W. H. (2000) · ASAIO Journal · doi:10.1097/00002480-200001000-00002 · Cited by 584
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 405
Morphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Self-citation
Cited by
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Calabrese Barton, S., Gallaway, J., & Atanassov, P. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,394
(2008) · Wiley eBooks · doi:10.1002/9780470294154 · Cited by 1,378
Cross-modal plasticity: where and how?
Bavelier, D., & Neville, H. J. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn848 · Cited by 1,040
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 867
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Self-citationBi, A., Cui, J., Ma, Y.-P., Olshevskaya, E., Pu, M., Dizhoor, A. M., & Pan, Z.-H. (2006) · Neuron · doi:10.1016/j.neuron.2006.02.026 · Cited by 771
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Lagali, P. S., Balya, D., Awatramani, G. B., Münch, T. A., Kim, D. S., Busskamp, V., Cepko, C. L., & Roska, B. (2008) · Nature Neuroscience · doi:10.1038/nn.2117 · Cited by 582
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Retinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
“(d) Other current approaches in humans Worldwide, several approaches to vision restoration via electronic implants are currently being tested [25–28].”
BackgroundSelf-citationRetinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 428
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
Self-citationWeiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0819 · Cited by 358
Direct and Indirect Activation of Cortical Neurons by Electrical Microstimulation
Tehovnik, E. J., Tolias, A. S., Sultan, F., Slocum, W. M., & Logothetis, N. K. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00126.2006 · Cited by 357
Reiners, J., Nagel-Wolfrum, K., Jürgens, K., Märker, T., & Wolfrum, U. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2005.11.010 · Cited by 305
A fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
Maya-Vetencourt, J. F., Ghezzi, D., Antognazza, M. R., Colombo, E., Mete, M., Feyen, P., Desii, A., Buschiazzo, A., Di Paolo, M., Di Marco, S., et al. (2017) · Nature Materials · doi:10.1038/nmat4874 · Cited by 290
An Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266
Pattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259
Retinal Remodeling in Inherited Photoreceptor Degenerations
Marc, R. E., & Jones, B. W. (2003) · Molecular Neurobiology · doi:10.1385/mn:28:2:139 · Cited by 258
Butovas, S., & Schwarz, C. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00245.2003 · Cited by 246
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Demonstration of artificial visual percepts generated through thalamic microstimulation
Pezaris, J. S., & Reid, R. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608563104 · Cited by 195
Edwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193
Self-citationWhat blindness can tell us about seeing again: merging neuroplasticity and neuroprostheses
Merabet, L. B., Rizzo, J. F., Amedi, A., Somers, D. C., & Pascual-Leone, A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1586 · Cited by 179
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Self-citationBoinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
Development of visual Neuroprostheses: trends and challenges.
Fernandez, E. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0013-8 · Cited by 114
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Sommerhalder, J., Rappaz, B., de Haller, R., Fornos, A. P., Safran, A. B., & Pelizzone, M. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.017 · Cited by 116
Mind Reading and Writing: The Future of Neurotechnology
Roelfsema, P. R., Denys, D., & Klink, P. C. (2018) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2018.04.001 · Cited by 107
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110
Development of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity
Fernández, E., Pelayo, F., Romero, S., Bongard, M., Marin, C., Alfaro, A., & Merabet, L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r01 · Cited by 105
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Endo, T., Hirota, M., Morimoto, T., Nishida, K., Kishima, H., Terasawa, Y., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20367 · Cited by 101
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
A Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis
Monge, M., Raj, M., Nazari, M. H., Chang, H.-C., Zhao, Y., Weiland, J. D., Humayun, M. S., Tai, Y.-C., & Emami, A. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298334 · Cited by 85
Molecular Therapies for Inherited Retinal Diseases—Current Standing, Opportunities and Challenges
Vázquez-Domínguez, I., Garanto, A., & Collin, R. W. J. (2019) · Genes · doi:10.3390/genes10090654 · Cited by 80
Retinal Neurostimulator for a Multifocal Vision Prosthesis
Wong, Y. T., Dommel, N., Preston, P., Hallum, L. E., Lehmann, T., Lovell, N. H., & Suaning, G. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903958 · Cited by 79
Microstimulation of visual cortex to restore vision
Tehovnik, E. J., Slocum, W. M., Smirnakis, S. M., & Tolias, A. S. (2009) · Progress in Brain Research · doi:10.1016/s0079-6123(09)17524-6 · Cited by 71
Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68
Villalobos, J., Nayagam, D. A. X., Allen, P. J., McKelvie, P., Luu, C. D., Ayton, L. N., Freemantle, A. L., McPhedran, M., Basa, M., McGowan, C. C., et al. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10843 · Cited by 63
Li, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59
Sakaguchi, H., Kamei, M., Fujikado, T., Yonezawa, E., Ozawa, M., Cecilia-Gonzalez, C., Ustariz-Gonzalez, O., Quiroz-Mercado, H., & Tano, Y. (2009) · Journal of Artificial Organs · doi:10.1007/s10047-009-0467-2 · Cited by 58
Naycheva, L., Schatz, A., Röck, T., Willmann, G., Messias, A., Bartz-Schmidt, K. U., Zrenner, E., & Gekeler, F. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9612 · Cited by 55
Self-citationMobility and low contrast trip hazard avoidance using augmented depth
McCarthy, C., Walker, J. G., Lieby, P., Scott, A., & Barnes, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016003 · Cited by 49
Oculomotor behavior of blind patients seeing with a subretinal visual implant
Hafed, Z. M., Stingl, K., Bartz-Schmidt, K.-U., Gekeler, F., & Zrenner, E. (2016) · Vision Research · doi:10.1016/j.visres.2015.04.006 · Cited by 43
Self-citationParaskevoudi, N., & Pezaris, J. S. (2019) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00073 · Cited by 39
The Subretinal Implant ALPHA: Implantation and Functional Results
Zrenner, E., Bartz-Schmidt, K. U., Besch, D., Gekeler, F., Koitschev, A., Sachs, H. G., & Stingl, K. (2017) · Artificial Vision · doi:10.1007/978-3-319-41876-6_6 · Cited by 27
Self-citationParaskevoudi, N., & Pezaris, J. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-86996-4 · Cited by 16
Lateral geniculate body evoked potentials elicited by visual and electrical stimulation
Choi, C. W., Kim, P. S., Shin, S. A., Yang, J. Y., & Yang, Y. S. (2014) · Korean Journal of Ophthalmology · doi:10.3341/kjo.2014.28.4.337 · Cited by 7
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7
Metadata
- Authors
- Zrenner, E.
- Venue
- Science
- Published
- 2002-02-08
- Volume
- 295
- Issue
- 5557
- Pages
- 1022-1025
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1980623242
- Cited by
- 724
- References
- 31
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.