The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage
Open accessPublished version of a preprint
The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index; 57 of the 132 sources its claims cite were checked for support.
Abstract
Face coverings are a key component of preventive health measure strategies to mitigate the spread of respiratory illnesses. In this study five groups of masks were investigated that are of particular relevance to the SARS-CoV-2 pandemic: re-usable, fabric two-layer and multi-layer masks, disposable procedure/surgical masks, KN95 and N95 filtering facepiece respirators. Experimental work focussed on the particle penetration through mask materials as a function of particle diameter, and the total inward leakage protection performance of the mask system. Geometric mean fabric protection factors varied from 1.78 to 144.5 for the fabric two-layer and KN95 materials, corresponding to overall filtration efficiencies of 43.8% and 99.3% using a flow rate of 17 L/min, equivalent to a breathing expiration rate for a person in a sedentary or standing position conversing with another individual. Geometric mean total inward leakage protection factors for the 2-layer, multi-layer and procedure masks were <2.3, while 6.2 was achieved for the KN95 masks. The highest values were measured for the N95 group at 165.7. Mask performance is dominated by face seal leakage. Despite the additional filtering layers added to cloth masks, and the higher filtration efficiency of the materials used in disposable procedure and KN95 masks, the total inward leakage protection factor was only marginally improved. N95 FFRs were the only mask group investigated that provided not only high filtration efficiency but high total inward leakage protection, and remain the best option to protect individuals from exposure to aerosol in high risk settings. The Mask Quality Factor and total inward leakage performance are very useful to determine the best options for masking. However, it is highly recommended that testing is undertaken on prospective products, or guidance is sought from impartial authorities, to confirm they meet any implied standards.
Overview
CoChat Summary
TL;DR
This study measured particle filtration through mask materials and total inward leakage (TIL) for reusable cloth, disposable procedure, KN95, and N95 masks. It found that mask performance is dominated by face-seal leakage: N95 FFRs provided high filtration and high TIL protection, while cloth and procedure masks provided only marginal TIL protection despite material differences.
Key findings
- Geometric mean fabric protection factors (FPF) ranged from 1.78 for 2-layer fabric masks to 144.5 for KN95 materials, corresponding to overall filtration efficiencies of 43.8% and 99.3% at 17 L/min; N95 FFR materials had a geometric mean FPF of 69.8 (~1.4% overall penetration).
- Geometric mean total inward leakage protection factors (TILPF) were 1.42 for 2-layer fabric masks, 1.78 for multi-layer fabric masks, 2.26 for disposable procedure masks, 6.20 for KN95 masks, and 165.7 for N95 FFRs, corresponding to TIL penetration of 70%, 56.5%, 44.2%, 16.1%, and 0.60%, respectively.
- Adding filtering layers to cloth masks did not improve TILPF; multi-layer masks with polypropylene filtering material were indistinguishable in penetration from 2-layer masks, and PM 2.5 filter inserts gave FPF ~71 but TILPF only 1.8.
- N95 FFRs were the only group with both high filtration efficiency and high TIL protection; their geometric mean quantitative fit factor was ~644, equivalent to a face-seal efficiency of 99.84%.
Methods
- Five mask groups were tested: reusable fabric 2-layer and multi-layer masks, disposable procedure/surgical masks, KN95 masks, and N95 FFRs. Filtration testing used NaCl aerosol with SMPS/APS over ~0.027–5.0 μm at 17 L/min; TIL testing used a TSI PortaCount 8038 with seven CSA-recommended activities.
- TIL tests recruited 11 trained subjects from DRDC Suffield, selected for a cross-section of sex, age, height, weight, and facial size; all were quantitatively fit tested to FFRs (fit factor >100).
- Analyses included geometric mean FPF and TILPF, harmonic mean FPF, ANOVA with Bonholm/Tukey tests, and Kruskal-Wallis with Dunn’s test where normality failed.
Limitations
- The paper states that its estimates of penetrating virion numbers should not be taken as absolute, because the assumption that virion number depends directly on particle volume has not been verified.
- The paper notes that KN95 performance has been found to be inconsistent across models, and recommends testing prospective products or seeking impartial guidance to confirm implied standards.
- Evident from the text: TIL testing used a small, trained volunteer pool (11 subjects) and only one N95 model (3M 9210) for TIL, so results may not generalize to untrained users or other N95 models; filtration testing was at 17 L/min rather than standard 28 or 85 L/min, and some tests had a maximum upper particle range of ~3.5 μm due to insufficient larger particles.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
23 Valid · 3 Not valid · 37 Not checked · 139 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Measured protection factors (PFs) of N95 FFRs when worn in the workplace have been shown to give considerably lower protection [58, 59]”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 1 Introduction
What the sources say
- Not checked — no full text of the sourcecites [58] Duncan S, Bodurtha P, Dickson E, Bourgeois C, Jensen C, Naqvi S. The impact of extreme reuse and extended wear conditions on protection provided by a surgical-style N95 filtering facepiece respirator. J Occup Environ Hyg. 2020 Nov-Dec; 17(11–12): 546– 559. doi: 10.1080/15459624.2020.1829633 33166226 source
- Partly supportedcites [59] Lee SA, Grinshpun S, & Reponen T. Respiratory performance offered by N95 respirators and surgical masks: human subject evaluation with NaCl aerosol representing bacterial and viral particle size range. Ann Occup Hyg. 2008 Apr; 52(3): 177– 185. doi: 10.1093/annhyg/men005 18326870 PMC7539566 sourceExperimental — accuracy not yet measured
The Results report measured N95 protection factors below the assigned factor of 10 for some respirators. The Discussion says laboratory-measured factors are expected to be greater than field factors, but this study did not measure protection factors during workplace use. It therefore supports the direction of the claim, not its attribution to workplace measurements. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Inward leakage due to gaps in the fit has been demonstrated to play a critical role in the ability of a mask or respirator to protect against exposure to particulates [4, 59, 82–84].”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 1 Introduction
What the sources say
- Supportedcites [4] Hill CH, Hull MS, MacCuspie RI. Testing of commercial masks and respirators and cotton mask insert materials using SARS-CoV-2 virion-sized particulates: comparison of ideal aerosol filtration efficiency versus fitted filtration efficiency. Nano Lett. 2020 Sep; Published online: acs.nanolett.0c0.182. doi: 10.1021/acs.nanolett.0c03182 32986441 PMC7534799 source
The paper states that fit plays a critical role in protecting the wearer from particulate inhalation. It reports substantially lower filtration efficiency when masks were worn on a headform than when their materials were tested in a sealed setup, and identifies gaps around facial contours as likely leakage points. (LLM, conf=0.94)
- Supportedcites [59] Lee SA, Grinshpun S, & Reponen T. Respiratory performance offered by N95 respirators and surgical masks: human subject evaluation with NaCl aerosol representing bacterial and viral particle size range. Ann Occup Hyg. 2008 Apr; 52(3): 177– 185. doi: 10.1093/annhyg/men005 18326870 PMC7539566 source
The Introduction (page not available in our copy) says airborne particles can enter through face-seal leaks and be inhaled, and identifies face-seal leakage as a component of measured respiratory protection alongside filter penetration. This supports the broad claim that gaps in fit matter to protection, without implying that leakage is the only factor. (LLM, conf=0.86)
- Supportedcites [82] Grinshpun SA, Haruta H, Enringer RM, Reponen T, McKay RT, Lee S-A. Performance of an N95 filtering facepiece particulate respirator and a surgical mask during human breathing: two pathways for particle penetration. J Occup Environ Hyg. 2009 Oct; 6(10): 593– 603. doi: 10.1080/15459620903120086 19598054 PMC7196699 source
The Summary and Practical Implications section identifies faceseal leakage as the main pathway by which submicrometer particles entered the tested respirator and mask, and recommends improving fit to minimize it. This supports the claim that gaps in fit play a critical role in protection against particulates. (LLM, conf=0.93)
- Not checked — no full text of the sourcecites [83] Qian Y, Willeke K, Grinshpun, Donelly J, Coffey CC. Performance of N95 respirators: filtration efficiency for airborne microbial and inert particles. Am Ind Hyg Assoc J. 1998 Feb; 59(2): 128– 132. doi: 10.1080/15428119891010389 9487666 source
- Supportedcites [84] Sickbert-Bennett E, Samet J, Clapp P, Chen H, Berntsen J, Zeman KL, et al. Filtration Efficiency of Hospital Face Mask Alternatives Available for Use During the COVID-19 Pandemic. JAMA Intern Med. 2020 Aug; 180(12): 1607– 1612. doi: 10.1001/jamainternmed.2020.4221 32780113 PMC7420816 source
The Discussion (page not supplied) reports visible gaps in ear-loop procedure masks alongside low fitted filtration efficiency, and says the findings illustrate the importance of fit for the effectiveness of masks and respirators. The study measured particles behind the mask relative to ambient particles, supporting the claim about protection from particulate exposure. (LLM, conf=0.92)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The ability of materials used in homemade face coverings to remove particulates is completely dependent on the characteristics of the fabric, such as the weave type and fiber structure [4, 62, 81], as well as number of fabric layers.”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 1 Introduction
What the sources say
- Partly supportedcites [4] Hill CH, Hull MS, MacCuspie RI. Testing of commercial masks and respirators and cotton mask insert materials using SARS-CoV-2 virion-sized particulates: comparison of ideal aerosol filtration efficiency versus fitted filtration efficiency. Nano Lett. 2020 Sep; Published online: acs.nanolett.0c0.182. doi: 10.1021/acs.nanolett.0c03182 32986441 PMC7534799 sourceExperimental — accuracy not yet measured
The Abstract (page not provided) reports different filtration efficiencies for tested materials and layer configurations, supporting a role for material properties. It does not establish effects of weave type or fiber structure specifically, and its finding that fit, leakage, permeability, and pliability affect filtration does not support the claim that removal is completely dependent on the listed fabric characteristics. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [62] Zangmeister CD, Radney J, Vicenzi E, Weaver JL. Filtration Efficiencies of Nanoscale Aerosol by Cloth Mask Materials Used to Slow the Spread of SARS-CoV-2. ACS Nano. 2020 Jun; 14(7): 9188– 9200. doi: 10.1021/acsnano.0c05025 32584542 source
- Not checked — no full text of the sourcecites [81] Drewnick F, Pikmann J, Fachinger F, Moormann L, Sprang F, Borrmann S. Aerosol filtration efficiency of household materials for homemade face masks: Influence of material properties, particle size, particle electrical charge, face velocity, and leaks. Aerosol Sci Technol. 2020 Oct; 55(1): 63– 79. source
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The use of NaCl particles as a challenge aerosol, and its associated size distribution, has been shown to be an appropriate simulant to represent size ranges of both bacteria and viruses [3, 59].”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 2 Materials and methods > 2.2 Evaluation of aerosol penetration through mask fabrics
What the sources say
- Could not verifycites [3] Davies A, Thompson KA, Giri K, Kafatos G, Walker J, Bennet A. Testing the Efficacy of Homemade Masks: Would They Protect in an Influenza Pandemic? Disaster Med Public Health Prep. 2013 Aug; 7(4), 413– 418. doi: 10.1017/dmp.2013.43 24229526 PMC7108646 sourceExperimental — accuracy not yet measured
The Microorganisms and Discussion sections describe bacterial and viral aerosols as size-based challenges, but neither identifies NaCl particles as a challenge aerosol. Searches for NaCl, sodium chloride, and salt aerosol found no passage assessing a NaCl size distribution as a simulant for bacteria and viruses; page numbers were not available in our copy. (LLM, conf=0.76)
- Supportedcites [59] Lee SA, Grinshpun S, & Reponen T. Respiratory performance offered by N95 respirators and surgical masks: human subject evaluation with NaCl aerosol representing bacterial and viral particle size range. Ann Occup Hyg. 2008 Apr; 52(3): 177– 185. doi: 10.1093/annhyg/men005 18326870 PMC7539566 source
The Methods (page not provided) identify NaCl particles as the challenge aerosol and state that the measured particle-size channels represent the size of most airborne viruses and bacteria. The Introduction (page not provided) likewise describes the study’s 0.0414–1.2625 μm range as representing bacterial and viral sizes. This supports the claim as a size-range comparison. (LLM, conf=0.90)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The literature is replete with examples showing that normal physiological respiratory activities such as sneezing, coughing, talking and even breathing, expel particles into the local environment where individuals socialise and work [6–11].”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 1 Introduction
What the sources say
- Supportedcites [6] Han Z, Weng W, Huang Q. Characterizations of particle size distribution of the droplets exhaled by sneeze. J R Soc Interface. 2013 Nov; 10(88): 20130560 doi: 10.1098/rsif.2013.0560 24026469 PMC3785820 source
The Introduction describes exhaled droplets from respiratory activities and identifies literature on droplets produced by coughing, sneezing, speech and breathing. It also describes droplet spray entering the surrounding air, supporting the cited general statement. (LLM, conf=0.92)
- Partly supportedcites [7] Hersen G, Stéphane M, Robine E, Géhin E, Corbet S, Vabert A, et al. Impact of Health on Particle Size of Exhaled Respiratory Aerosols: Case-control Study. Clean (Weinh). 2008 July; 36(7): 572– 577. doi: 10.1002/clen.200700189 32313583 PMC7162260 sourceExperimental — accuracy not yet measured
The Introduction (p. n/a, sec. 1) states that 'infected individuals can emit particles in the air while talking, sneezing or coughing' and that these droplets 'may carry microorganisms and are likely to contaminate other people', which supports the sneezing/coughing/talking half of the claim; sec. 3.2 also shows that healthy controls emit particles in their exhaled breath. However, our copy frames the emission statement for infected individuals rather than as a universal 'normal physiological' activity, and it never singles out breathing as an emitting activity — in the test protocol (sec. 2.6) the first 10 s without coughing is recorded only as 'background noise', and droplets in the exhaled breath of healthy subjects is credited to Papineni and Rosenthal [21]. Nor does the paper discuss the 'local environment where individuals socialise and work'. So part of what the citing sentence attributes to this source is present and part is not. (LLM, conf=0.70)
- Not checked — no full text of the sourcecites [8] Loudon R, Roberts RM. Droplet Expulsion from the Respiratory TRACT. Am Rev Respir Dis. 1967 Mar; 95(3): 435– 442. 6018703 doi:10.1164/arrd.1967.95.3.435
- Supportedcites [9] Asadi S, Wexler A, Cappa C, Barreda S, Bouvier N, & Ristenpart W. Aerosol emission and superemission during human speech increase with voice loudness. Nature; 2019 Feb. 9 p. Report No.: 2348. doi: 10.1038/s41598-019-38808-z 30787335 PMC6382806 source
The Introduction explicitly states that sneezing, coughing, talking, and breathing expel particles. The Abstract also describes particle emission during speech and coughing or sneezing. (LLM, conf=0.94)
- Not checked — no full text of the sourcecites [10] Yang S, Lee G, Chen CM, Wu C-C, Yo K-P. The Size and Concentration of Droplets Generated by Coughing in Human Subjects. (484–494, Ed.) J Aerosol Med. 2007; 20(4): 484– 496. doi: 10.1089/jam.2007.0610 18158720 source
- Partly supportedcites [11] Johnson G, Morawska L. The Mechanism of Breath Aerosol Formation. Journal of Aerosol Medicine and Pulmonary Drug Delivery. 2009 Sep; 22(3): 229– 237. doi: 10.1089/jamp.2008.0720 19415984 sourceExperimental — accuracy not yet measured
The Introduction states that normal breathing produces aerosol particles and compares their concentrations with those produced by coughing. The Methods describe collecting aerosol emitted by subjects, supporting release into the surrounding air. The paper does not address sneezing or talking, so it supports only part of the list of activities. (LLM, conf=0.86)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
117 more claims · 7 with their cited sources checked
Create a free account to see all 202 claims and to verify the 4 references still open.
- It may state two separate claims as one. 54
- Probably not a substantial claim. 34
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Within the respirator mask class, different designs (e.g., head and neck straps for N95 vs. ear loops for KN95) may yield tradeoffs between comfort and performance, as demonstrated by laboratory tests [26,55].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [55]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 4 Discussion > 4.1 Particulate penetration through mask fabrics
“The geometric mean FPF for the multi-layer mask group was higher at 3.61 (GSdev 2.58)”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 3 Results > 3.1 Particulate penetration through mask fabrics
“| Multi-layer masks | 45.2 (0.37) | 3.61 (1.57) | ~28 | 31.4 to 60.8 | 4.87 |”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 4 Discussion > 4.1 Particulate penetration through mask fabrics
“The geometric mean FPF of common apparel materials used in 2-layer mask was 1.78 (GSdev 0.54).”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 3 Results > 3.1 Particulate penetration through mask fabrics
“| Fabric 2-layer masks | 91.9 (0.809) | 1.78 (1.22) | ~56 | 22.6 to 375.7 | 4.87 |”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 2 Materials and methods > 2.1 Test items
“The N95 FFR group included seven models:”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 2 Materials and methods > 2.1 Test items
“3M™ model 1870 (fold style); Halyard Health, model FLUIDSHIELD 2 N95 (duck bill fold style); North Safety Products model 7130N95 (cup style); Gerson model 2130 N95 Respirator, Louis M. Gerson Co., (rectangular cup style); 3M™ model 8110s (cup style, size small); 3M™ model 9210 (fold style).”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 3 Results > 3.1 Particulate penetration through mask fabrics
“a total inward leakage requirement of ≤ 8%, equivalent to a FF of ≤ 12.5 [89].”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 4 Discussion > 4.2 Mask total inward leakage protection factors
“a total inward leakage requirement of ≤ 8% [89] (equivalent to a TILPF of ≥12.5)”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 4 Discussion > 4.1 Particulate penetration through mask fabrics
“Disposable procedure mask materials provide higher filtration efficiency, affording a geometric mean FPF of 9.73 (GSdev 1.60)”
§ The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage > 3 Results > 3.1 Particulate penetration through mask fabrics
“| Disposable procedure masks | 26.4 (0.058) | 9.73 (1.17) | ~10 | 21.6 to 50.0 | 4.87 |”
Citations
Cites
Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1
van Doremalen, N., Bushmaker, T., Morris, D. H., Holbrook, M. G., Gamble, A., Williamson, B. N., Tamin, A., Harcourt, J. L., Thornburg, N. J., Gerber, S. I., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2004973 · Cited by 9,951
Chu, D. K., Akl, E. A., Duda, S., Solo, K., Yaacoub, S., Schünemann, H. J., Chu, D. K., Akl, E. A., El-harakeh, A., Bognanni, A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31142-9 · Cited by 3,843
International Organization for Standardization (ISO)
Nahler, G. (2009) · Dictionary of Pharmaceutical Medicine · doi:10.1007/978-3-211-89836-9_723 · Cited by 3,677
Respiratory virus shedding in exhaled breath and efficacy of face masks
Leung, N. H. L., Chu, D. K. W., Shiu, E. Y. C., Chan, K.-H., McDevitt, J. J., Hau, B. J. P., Yen, H.-L., Li, Y., Ip, D. K. M., Peiris, J. S. M., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0843-2 · Cited by 2,270
Ong, S. W. X., Tan, Y. K., Chia, P. Y., Lee, T. H., Ng, O. T., Wong, M. S. Y., & Marimuthu, K. (2020) · JAMA · doi:10.1001/jama.2020.3227 · Cited by 2,140
Aerodynamic Analysis of SARS-CoV-2 in Two Wuhan Hospitals
Liu, Y., Ning, Z., Chen, Y., Guo, M., Liu, Y., Gali, N. K., Sun, L., Duan, Y., Cai, J., Westerdahl, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2271-3 · Cited by 1,872
Airborne transmission of SARS-CoV-2: The world should face the reality
Morawska, L., & Cao, J. (2020) · Environment International · doi:10.1016/j.envint.2020.105730 · Cited by 1,728
Aerosol Measurement: Principles, Techniques, and Applications
(2011) · Wiley eBooks · doi:10.1002/9781118001684 · Cited by 1,352
Identifying airborne transmission as the dominant route for the spread of COVID-19
Zhang, R., Li, Y., Zhang, A. L., Wang, Y., & Molina, M. J. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2009637117 · Cited by 1,236
It is time to address airborne transmission of coronavirus disease 2019 (COVID-19)
Morawska, L., & Milton, D. K. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa939 · Cited by 1,189
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
Bourouiba, L. (2020) · JAMA · doi:10.1001/jama.2020.4756 · Cited by 1,066
Guo, Z.-D., Wang, Z.-Y., Zhang, S.-F., Li, X., Li, L., Li, C., Cui, Y., Fu, R.-B., Dong, Y.-Z., Chi, X.-Y., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2607.200885 · Cited by 1,065
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Aerosol filtration efficiency of common fabrics used in respiratory cloth masks
Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S. (2020) · ACS Nano · doi:10.1021/acsnano.0c03252 · Cited by 934
Aerosol Emission and Superemission during Human Speech Increase with Voice Loudness
Asadi, S., Wexler, A. S., Cappa, C. D., Barreda, S., Bouvier, N. M., & Ristenpart, W. D. (2019) · Scientific Reports · doi:10.1038/s41598-019-38808-z · Cited by 919
Reducing transmission of SARS-CoV-2
Prather, K. A., Wang, C. C., & Schooley, R. T. (2020) · Science · doi:10.1126/science.abc6197 · Cited by 850
Violent expiratory events: on coughing and sneezing
Bourouiba, L., Dehandschoewercker, E., & Bush, J. W. M. (2014) · Journal of Fluid Mechanics · doi:10.1017/jfm.2014.88 · Cited by 828
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
Transmission of influenza A in human beings
Brankston, G., Gitterman, L., Hirji, Z., Lemieux, C., & Gardam, M. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70029-4 · Cited by 744
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients
Lednicky, J. A., Lauzardo, M., Fan, Z. H., Jutla, A., Tilly, T. B., Gangwar, M., Usmani, M., Shankar, S. N., Mohamed, K., Eiguren-Fernandez, A., et al. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.09.025 · Cited by 683
Milton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
(2001) · Cited by 666
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community
Yan, J., Grantham, M., Pantelic, J., Bueno de Mesquita, P. J., Albert, B., Liu, F., Ehrman, S., Milton, D. K., EMIT Consortium, Adamson, W., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716561115 · Cited by 534
Airborne or Droplet Precautions for Health Workers Treating Coronavirus Disease 2019?
Bahl, P., Doolan, C., de Silva, C., Chughtai, A. A., Bourouiba, L., & MacIntyre, C. R. (2022) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiaa189 · Cited by 513
Testing the Efficacy of Homemade Masks: Would They Protect in an Influenza Pandemic?
Davies, A., Thompson, K.-A., Giri, K., Kafatos, G., Walker, J., & Bennett, A. (2013) · Disaster Medicine and Public Health Preparedness · doi:10.1017/dmp.2013.43 · Cited by 498
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
Asadi, S., Cappa, C. D., Barreda, S., Wexler, A. S., Bouvier, N. M., & Ristenpart, W. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-72798-7 · Cited by 480
The Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
Vuorinen, V., Aarnio, M., Alava, M., Alopaeus, V., Atanasova, N., Auvinen, M., Balasubramanian, N., Bordbar, H., Erästö, P., Grande, R., et al. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104866 · Cited by 472
Loeb, M., Dafoe, N., Mahony, J., John, M., Sarabia, A., Glavin, V., Webby, R., Smieja, M., Earn, D. J. D., Chong, S., et al. (2009) · JAMA · doi:10.1001/jama.2009.1466 · Cited by 465
van der Sande, M., Teunis, P., & Sabel, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002618 · Cited by 458
Persistence of Severe Acute Respiratory Syndrome Coronavirus 2 in Aerosol Suspensions
Fears, A. C., Klimstra, W. B., Duprex, P., Hartman, A., Weaver, S. C., Plante, K. S., Mirchandani, D., Plante, J. A., Aguilar, P. V., Fernández, D., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2609.201806 · Cited by 453
Fears, A. C., Klimstra, W. B., Duprex, P., Hartman, A., Weaver, S. C., Plante, K. C., Mirchandani, D., Plante, J. A., Aguilar, P. V., Fernández, D., et al. (2020) · doi:10.1101/2020.04.13.20063784 · Cited by 453
Radonovich, L. J., Simberkoff, M. S., Bessesen, M. T., Brown, A. C., Cummings, D. A. T., Gaydos, C. A., Los, J. G., Krosche, A. E., Gibert, C. L., Gorse, G. J., et al. (2019) · JAMA · doi:10.1001/jama.2019.11645 · Cited by 447
The Mechanism of Breath Aerosol Formation
Johnson, G. R., & Morawska, L. (2009) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2008.0720 · Cited by 434
Consideration of the Aerosol Transmission for COVID-19 and Public Health
Anderson, E. L., Turnham, P., Griffin, J. R., & Clarke, C. C. (2020) · Risk Analysis · doi:10.1111/risa.13500 · Cited by 433
Zhu, S., Kato, S., & Yang, J.-H. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.06.024 · Cited by 428
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423
Effects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416
Airborne transmission of SARS-CoV-2
Prather, K. A., Marr, L. C., Schooley, R. T., McDiarmid, M. A., Wilson, M. E., & Milton, D. K. (2020) · Science · doi:10.1126/science.abf0521 · Cited by 400
An overview of filtration efficiency through the masks: Mechanisms of the aerosols penetration
Tcharkhtchi, A., Abbasnezhad, N., Zarbini Seydani, M., Zirak, N., Farzaneh, S., & Shirinbayan, M. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.08.002 · Cited by 395
Characterizations of particle size distribution of the droplets exhaled by sneeze
Han, Z. Y., Weng, W. G., & Huang, Q. Y. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0560 · Cited by 383
Face mask use in the general population and optimal resource allocation during the COVID-19 pandemic
Worby, C. J., & Chang, H.-H. (2020) · Nature Communications · doi:10.1038/s41467-020-17922-x · Cited by 379
Bałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq044 · Cited by 352
Tang, J. W., Bahnfleth, W. P., Bluyssen, P. M., Buonanno, G., Jimenez, J. L., Kurnitski, J., Li, Y., Miller, S., Sekhar, C., Morawska, L., et al. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.12.022 · Cited by 350
Measurement of Airborne Influenza Virus in a Hospital Emergency Department
Blachere, F. M., Lindsley, W. G., Pearce, T. A., Anderson, S. E., Fisher, M., Khakoo, R., Meade, B. J., Lander, O., Davis, S., Thewlis, R. E., et al. (2009) · Clinical Infectious Diseases · doi:10.1086/596478 · Cited by 342
Enhanced spread of expiratory droplets by turbulence in a cough jet
Wei, J., & Li, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.018 · Cited by 321
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294
Visualization of sneeze ejecta: steps of fluid fragmentation leading to respiratory droplets
Scharfman, B. E., Techet, A. H., Bush, J. W. M., & Bourouiba, L. (2016) · Experiments in Fluids · doi:10.1007/s00348-015-2078-4 · Cited by 287
Zangmeister, C. D., Radney, J. G., Vicenzi, E. P., & Weaver, J. L. (2020) · ACS Nano · doi:10.1021/acsnano.0c05025 · Cited by 276
Zhao, M., Liao, L., Xiao, W., Yu, X., Wang, H., Wang, Q., Lin, Y. L., Kilinc-Balci, F. S., Price, A., Chu, L., et al. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c02211 · Cited by 266
Yang, W., Elankumaran, S., & Marr, L. C. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0686 · Cited by 260
MacIntyre, C. R., Wang, Q., Cauchemez, S., Seale, H., Dwyer, D. E., Yang, P., Shi, W., Gao, Z., Pang, X., Zhang, Y., et al. (2011) · Influenza and Other Respiratory Viruses · doi:10.1111/j.1750-2659.2011.00198.x · Cited by 257
Droplet expulsion from the respiratory tract.
(1967) · PubMed · doi:10.1164/arrd.1967.95.3.435 · Cited by 240
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mei058 · Cited by 234
Exhaled Particles and Small Airways
Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., & Olin, A.-C. (2019) · Respiratory Research · doi:10.1186/s12931-019-0970-9 · Cited by 218
Lindsley, W. G., Blachere, F. M., Davis, K. A., Pearce, T. A., Fisher, M. A., Khakoo, R., Davis, S. M., Rogers, M. E., Thewlis, R. E., Posada, J. A., et al. (2010) · Clinical Infectious Diseases · doi:10.1086/650457 · Cited by 217
Smither, S. J., Eastaugh, L. S., Findlay, J. S., & Lever, M. S. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1777906 · Cited by 208
Evaluating the Efficacy of Cloth Facemasks in Reducing Particulate Matter Exposure
Shakya, K. M., Noyes, A., Kallin, R., & Peltier, R. E. (2017) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2016.42 · Cited by 202
Drewnick, F., Pikmann, J., Fachinger, F., Moormann, L., Sprang, F., & Borrmann, S. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2020.1817846 · Cited by 199
Fundamental protective mechanisms of face masks against droplet infections
Kähler, C. J., & Hain, R. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105617 · Cited by 191
A randomized clinical trial of three options for N95 respirators and medical masks in health workers
MacIntyre, C. R., Wang, Q., Seale, H., Yang, P., Shi, W., Gao, Z., Rahman, B., Zhang, Y., Wang, X., Newall, A. T., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201207-1164oc · Cited by 189
New respirator fit test panels representing the current U.S. civilian work force
Zhuang, Z., Bradtmiller, B., & Shaffer, R. E. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701497538 · Cited by 187
Clapp, P. W., Sickbert-Bennett, E. E., Samet, J. M., Berntsen, J., Zeman, K. L., Anderson, D. J., Weber, D. J., Bennett, W. D., & Program, U. C. F. D. C. A. P. E. (2021) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.8168 · Cited by 167
Exhalation of respiratory viruses by breathing, coughing, and talking
Stelzer‐Braid, S., Oliver, B. G., Blazey, A. J., Argent, E., Newsome, T. P., Rawlinson, W. D., & Tovey, E. R. (2009) · Journal of Medical Virology · doi:10.1002/jmv.21556 · Cited by 165
Sickbert-Bennett, E. E., Samet, J. M., Clapp, P. W., Chen, H., Berntsen, J., Zeman, K. L., Tong, H., Weber, D. J., & Bennett, W. D. (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.4221 · Cited by 164
Survival of aerosolized coronavirus in the ambient air
Pyankov, O. V., Bodnev, S. A., Pyankova, O. G., & Agranovski, I. E. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2017.09.009 · Cited by 153
Viable influenza A virus in airborne particles expelled during coughs versus exhalations
Lindsley, W. G., Blachere, F. M., Beezhold, D. H., Thewlis, R. E., Noorbakhsh, B., Othumpangat, S., Goldsmith, W. T., McMillen, C. M., Andrew, M. E., Burrell, C. N., et al. (2016) · Influenza and Other Respiratory Viruses · doi:10.1111/irv.12390 · Cited by 147
Review of the Breathability and Filtration Efficiency of Common Household Materials for Face Masks
Kwong, L. H., Wilson, R., Kumar, S., Crider, Y. S., Sanchez, Y. R., Rempel, D., & Pillarisetti, A. (2021) · ACS Nano · doi:10.1021/acsnano.0c10146 · Cited by 137
Effectiveness of surgical masks against influenza bioaerosols
Makison Booth, C., Clayton, M., Crook, B., & Gawn, J. M. (2013) · Journal of Hospital Infection · doi:10.1016/j.jhin.2013.02.007 · Cited by 132
Jung, H., Kim, J. K., Lee, S., Lee, J., Kim, J., Tsai, P., & Yoon, C. (2014) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2013.06.0201 · Cited by 128
Fitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490433799 · Cited by 119
Mechanisms of Airborne Infection via Evaporating and Sedimenting Droplets Produced by Speaking
Netz, R. R. (2020) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.0c05229 · Cited by 108
Lee, J., Yoo, D., Ryu, S., Ham, S., Lee, K., Yeo, M.-S., Min, K., & Yoon, C. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2018.01.0031 · Cited by 107
Human convective boundary layer and its interaction with room ventilation flow
Licina, D., Melikov, A., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12120 · Cited by 104
Bourouiba, L. (2016) · New England Journal of Medicine · doi:10.1056/nejmicm1501197 · Cited by 104
Hill, W. C., Hull, M. S., & MacCuspie, R. I. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c03182 · Cited by 88
A New Method for Sampling and Detection of Exhaled Respiratory Virus Aerosols
Huynh, K. N., Oliver, B. G., Stelzer, S., Rawlinson, W. D., & Tovey, E. R. (2008) · Clinical Infectious Diseases · doi:10.1086/523000 · Cited by 84
Parienta, D., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2010.10.005 · Cited by 82
(1951) · PubMed · Cited by 80
Advice on the use of masks in the context of COVID-19: interim guidance, 5 June 2020
Attaran, B. (2021) · Cited by 78
Licina, D., Melikov, A., Pantelic, J., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12177 · Cited by 69
Impact of Health on Particle Size of Exhaled Respiratory Aerosols: Case‐control Study
Hersen, G., Moularat, S., Robine, E., Géhin, E., Corbet, S., Vabret, A., & Freymuth, F. (2008) · CLEAN – Soil, Air, Water · doi:10.1002/clen.200700189 · Cited by 56
Rengasamy, S., Miller, A., & Eimer, B. C. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2010.515556 · Cited by 54
Nanoparticle Penetration through NIOSH-Approved N95 Filtering-facepiece Respirators
Rengasamy, S. (2007) · Medical Entomology and Zoology · Cited by 54
Simulated workplace protection factors for half-facepiece respiratory protective devices
Duling, M. G., Lawrence, R. B., Slaven, J. E., & Coffey, C. C. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701346925 · Cited by 52
Fabian, P., McDevitt, J. J., Lee, W.-M., Houseman, E. A., & Milton, D. K. (2009) · J. Environ. Monit. · doi:10.1039/b813520g · Cited by 49
Gao, S., Koehler, R. H., Yermakov, M., & Grinshpun, S. A. (2016) · Annals of Occupational Hygiene · doi:10.1093/annhyg/mew006 · Cited by 46
Liverman, C. T., Ta, H., Meb, R., & Ki, S. (2009) · Cited by 37
Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S. (2020) · ACS Nano · doi:10.1021/acsnano.0c04897 · Cited by 30
Duncan, S., Bodurtha, P., Bourgeois, C., Dickson, E., Jensen, C., & Naqvi, S. (2020) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2020.1829633 · Cited by 14
Self-citationElmashae, R. B. Y., Grinshpun, S. A., Reponen, T., Yermakov, M., & Riddle, R. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1319571 · Cited by 12
Fibered boundaries and calorons
Larraín-Hubach, A. (2020) · New Zealand journal of mathematics · doi:10.53733/43 · Cited by 1
Research works printed but not linked: 2
- L Bourouiba, 2016, Images in Clinical Medicine. A Sneeze, N Engl J Med, 375, e15
- J Gawn, 2008, Evaluating the protection afforded by surgical masks against influenza bioaerosols
Cited by
Impact of community masking on COVID-19: a cluster-randomized trial in Bangladesh
Abaluck, J., Kwong, L. H., Styczynski, A., Haque, A., Kabir, M. A., Bates-Jefferys, E., Crawford, E., Benjamin-Chung, J., Raihan, S., Rahman, S., et al. (2022) · Science · doi:10.1126/science.abi9069 · Cited by 333
“Although cloth masks have less leakage because they fit the face more closely (55) and can be sewn without specialized equipment, they are an order of magnitude more expensive than surgical masks.”
A conformable sensory face mask for decoding biological and environmental signals
Kim, J., Marcus, C., Ono, R., Sadat, D., Mirzazadeh, A., Jens, M., Fernandez, S. V., Zheng, S., Durak, T., & Dağdeviren, C. (2022) · Nature Electronics · doi:10.1038/s41928-022-00851-6 · Cited by 101
“These results also showed comparable mask fit quantity values reported by other researchers 11,38 .”
Masks and respirators for prevention of respiratory infections: a state of the science review
Greenhalgh, T., MacIntyre, C. R., Baker, M. G., Bhattacharjee, S., Chughtai, A. A., Fisman, D. N., Kunasekaran, M. P., Kvalsvig, A., Lupton, D. A., Oliver, M., et al. (2024) · Clinical Microbiology Reviews · doi:10.1128/cmr.00124-23 · Cited by 132
Oliveira, A. M., Silva, A. L. P., Soares, A. M. V. M., Barceló, ., Duarte, A. C., & Rocha‐Santos, T. (2023) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2023.109308 · Cited by 59
Dai, H., & Zhao, B. (2022) · Building Simulation · doi:10.1007/s12273-022-0952-6 · Cited by 49
“Considering the influence of air leakage, the filtration efficiency can be set as 50% for ordinary medical surgical masks and 90% for N95 masks on virus-laden aerosols (Davies et al. 2013; Leung et al. 2020; Duncan et al. 2021).”
Metadata
- Authors
- Duncan, S., Bodurtha, P., & Naqvi, S.
- Affiliations
- Defence Research and Development Canada (CA)
- Corresponding author
- Duncan, Scott
- ORCID
- Duncan, Scott
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2021-10-06
- Volume
- 16
- Issue
- 10
- Pages
- e0258191
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC8494377
- OpenAlex
- W3202327157
- Cited by
- 75
- References
- 91
- Citations by year
- 2026: 8 · 2025: 7 · 2024: 21 · 2023: 16 · 2022: 20 · 2021: 3
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- medRxiv (acceptedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Social Sciences › Sociology and Political Science › COVID-19 Prevention and Impact
- Keywords
- face masks, cloth masks, KN95 masks, N95 respirators, surgical masks, filtration efficiency, particle penetration, SARS-CoV-2, aerosol protection, face coverings, respiratory protection
- MeSH terms
- COVID-19, SARS-CoV-2, N95 Respirators, Disposable Equipment, Equipment Design, Filtration, Humans, Masks, Respiratory Protective Devices, Textiles, Equipment Reuse
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.