The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the safety and efficacy of the artificial silicon retina (ASR) microchip implanted in the subretinal space to treat vision loss from retinitis pigmentosa. METHODS: The ASR microchip is a 2-mm-diameter silicon-based device that contains approximately 5000 microelectrode-tipped microphotodiodes and is powered by incident light. The right eyes of 6 patients with retinitis pigmentosa were implanted with the ASR microchip while the left eyes served as controls. Safety and visual function information was collected. RESULTS: During follow-up that ranged from 6 to 18 months, all ASRs functioned electrically. No patient showed signs of implant rejection, infection, inflammation, erosion, neovascularization, retinal detachment, or migration. Visual function improvements occurred in all patients and included unexpected improvements in retinal areas distant from the implant. MAIN OUTCOME MEASURES: Subjective improvements included improved perception of brightness, contrast, color, movement, shape, resolution, and visual field size. CONCLUSIONS: No significant safety-related adverse effects were observed. The observation of retinal visual improvement in areas far from the implant site suggests a possible generalized neurotrophic-type rescue effect on the damaged retina caused by the presence of the ASR. A larger clinical trial is indicated to further evaluate the safety and efficacy of a subretinally implanted ASR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2001) · New England Journal of Medicine · doi:10.1056/nejmoa000827 · Cited by 1,514
INHERITED RETINAL DYSTROPHY IN THE RAT
Dowling, J. E., & Sidman, R. L. (1962) · The Journal of Cell Biology · doi:10.1083/jcb.14.1.73 · Cited by 803
Preservation of the Inner Retina in Retinitis Pigmentosa: A Morphometric Analysis
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 643
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 601
Protection of mouse photoreceptors by survival factors in retinal degenerations.
LaVail, M. M., Yasumura, D., Matthes, M. T., Lau-Villacorta, C., Unoki, K., Sung, C. –., & Steinberg, R. H. (1998) · PubMed · Cited by 537
Injury-induced upregulation of bFGF and CNTF mRNAS in the rat retina
Wen, R., Song, Y., Cheng, T., Matthes, M., Yasumura, D., LaVail, M., & Steinberg, R. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-11-07377.1995 · Cited by 321
Natural Course of Retinitis Pigmentosa Over a Three-Year Interval
Berson, E. L., Sandberg, M. A., Rosner, B., Birch, D. G., & Hanson, A. H. (1985) · American Journal of Ophthalmology · doi:10.1016/0002-9394(85)90351-4 · Cited by 321
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Leake, P. A., Hradek, G. T., & Snyder, R. L. (1999) · The Journal of Comparative Neurology · doi:10.1002/(sici)1096-9861(19991004)412:4<543::aid-cne1>3.0.co;2-3 · Cited by 276
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
Self-citation
Cited by
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 467
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 428
Dias, M. F., Joo, K., Kemp, J. A., Fialho, S. L., da Silva Cunha, A., Woo, S. J., & Kwon, Y. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.10.004 · Cited by 413
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
“Such observations of improvement of remaining vision have been made also in previous attempts to restore vision by subretinal implants in RP patients (Chow et al., 2004).”
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Review on Micro- and Nanolithography Techniques and their Applications
Pimpin, A., & Srituravanich, W. (2012) · Engineering Journal · doi:10.4186/ej.2012.16.1.37 · Cited by 363
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Artificial silicon retina (ASR) from Optobionics, a Chicago based company, is the first implant of this kind that entered clinical trials (Chow et al., 2004).”
An Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266
Radtke, N. D., Aramant, R. B., Petry, H. M., Green, P. T., Pidwell, D. J., & Seiler, M. J. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.04.009 · Cited by 255
Neuroprotective strategies for retinal disease
Pardue, M. T., & Allen, R. S. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.02.002 · Cited by 237
“reported that subretinal microphotodiode arrays implanted into patients with RP for restoration had visual improvements in retinal regions far from the site of the electrical device (Chow et al., 2004).”
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Artificial vision: needs, functioning, and testing of a retinal electronic prosthesis
Chader, G. J., Weiland, J., & Humayun, M. S. (2009) · Progress in Brain Research · doi:10.1016/s0079-6123(09)17522-2 · Cited by 226
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6836 · Cited by 216
A Method for Generating Precise Temporal Patterns of Retinal Spiking Using Prosthetic Stimulation
Fried, S. I., Hsueh, H. A., & Werblin, F. S. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00849.2005 · Cited by 211
Advances in retinal prosthesis systems
Bloch, E., Luo, Y., & da Cruz, L. (2019) · Therapeutic Advances in Ophthalmology · doi:10.1177/2515841418817501 · Cited by 201
Retinal Prostheses: Current Clinical Results and Future Needs
Weiland, J. D., Cho, A. K., & Humayun, M. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.08.042 · Cited by 199
Demonstration of artificial visual percepts generated through thalamic microstimulation
Pezaris, J. S., & Reid, R. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608563104 · Cited by 195
Retinal implants: a systematic review: Table 1
Chuang, A. T., Margo, C. E., & Greenberg, P. B. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-303708 · Cited by 192
Fighting Blindness with Microelectronics
Zrenner, E. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007399 · Cited by 190
Weiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
What blindness can tell us about seeing again: merging neuroplasticity and neuroprostheses
Merabet, L. B., Rizzo, J. F., Amedi, A., Somers, D. C., & Pascual-Leone, A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1586 · Cited by 179
Weiland, J. D., & Humayun, M. S. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922589 · Cited by 179
Electrical Stimulation as a Means for Improving Vision
Sehic, A., Guo, S., Cho, K.-S., Corraya, R. M., Chen, D. F., & Utheim, T. P. (2016) · The American Journal of Pathology · doi:10.1016/j.ajpath.2016.07.017 · Cited by 162
“In 1873, Henri Dor reported the beneficial effects of ES on the eye via treatment of amblyopia, amauroses, glaucoma, retinochoroiditis, and white optic atrophy.8 In 1929, Otfrid Foerster, a German neurosurgeon, reported a neural response to ES in a patient’s visual cortex.9 In 1974, the ES of the visual system was sho…”
BackgroundStimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wachtler, T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 161
Roessler, G., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B., Goertz, M., Koch, C., Krisch, I., Sellhaus, B., Trieu, H. K., et al. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2752 · Cited by 161
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Electronic retinal implants and artificial vision: journey and present
Mills, J. O., Jalil, A., & Stanga, P. E. (2017) · Eye · doi:10.1038/eye.2017.65 · Cited by 133
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Lewis, P. M., & Rosenfeld, J. V. (2016) · Brain Research · doi:10.1016/j.brainres.2015.08.038 · Cited by 107
“E-mail addresse”
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Endo, T., Hirota, M., Morimoto, T., Nishida, K., Kishima, H., Terasawa, Y., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20367 · Cited by 101
Dagnelie, G., Barnett, D., Humayun, M. S., & Thompson, R. W. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0157 · Cited by 90
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Retinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
Psychophysical evaluation for visual prosthesis
Dagnelie, G. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160529 · Cited by 82
Bioengineering strategies for restoring vision
Cehajic-Kapetanovic, J., Singh, M. S., Zrenner, E., & MacLaren, R. E. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00836-4 · Cited by 79
Villalobos, J., Nayagam, D. A. X., Allen, P. J., McKelvie, P., Luu, C. D., Ayton, L. N., Freemantle, A. L., McPhedran, M., Basa, M., McGowan, C. C., et al. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10843 · Cited by 63
Wang, R., Huang, X., Liu, G., Wang, W., Dong, F., & Li, Z. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2039773 · Cited by 63
New Vision for Visual Prostheses
Farnum, A., & Pelled, G. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00036 · Cited by 58
“Early research has shown that photodiodes reliant solely on ambient light can induce neurotrophic effects, but are insufficient for phosphene generation (Chow et al., 2004; Palanker et al., 2005).”
BackgroundNaycheva, L., Schatz, A., Röck, T., Willmann, G., Messias, A., Bartz-Schmidt, K. U., Zrenner, E., & Gekeler, F. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9612 · Cited by 55
Advances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
“Six RP patients have been implanted with the ASR device [51].”
MethodRetinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Chen, S. C., Hallum, L. E., Suaning, G. J., & Lovell, N. H. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s13 · Cited by 31
The argus ii retinal prosthesis system
Bloch, E., & da Cruz, L. (2020) · Prosthesis · doi:10.5772/intechopen.84947 · Cited by 31
Yan, Y., Lu, Y., Li, M., Ma, Z., Cao, P., Chen, Y., Sun, X., Chai, X., Ren, Q., & Li, L. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-17543 · Cited by 20
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Visual Prostheses in the Era of Artificial Intelligence Technology
Sarbout, I., Gungor, A., Ounissi, M., Zaher, S., Ptito, M., Kupers, R., Racoceanu, D., & Milea, D. (2025) · Eye and Brain · doi:10.2147/eb.s524322 · Cited by 3
“Among the various models, Artificial Silicon Retina (ASR) retinal implant 30 developed by “Optobionics” (USA) was the first to receive FDA approval, in 2000.”
Navigating the regulatory pathway for an innovative bionic vision system
Chevrie, K. (2020) · Advanced Biomedical and Clinical Diagnostic and Surgical Guidance Systems XVIII · doi:10.1117/12.2560182 · Cited by 1
Metadata
- Authors
- Chow, A. Y.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2004-04-01
- Volume
- 122
- Issue
- 4
- Pages
- 460
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2095891880
- Cited by
- 511
- References
- 33
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.