The DOI matches its Crossref record; 104 of the 104 references it cites were found in a registry or an index.
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Open accessAbstract
Global burdens from existing or emerging infectious diseases emphasize the need for point-of-care (POC) diagnostics to enhance timely recognition and intervention. Molecular approaches based on PCR methods have made significant inroads by improving detection time and accuracy but are still largely hampered by resource-intensive processing in centralized laboratories, thereby precluding their routine bedside- or field-use. Microfluidic technologies have enabled miniaturization of PCR processes onto a chip device with potential benefits including speed, cost, portability, throughput, and automation. In this review, we provide an overview of recent advances in microfluidic PCR technologies and discuss practical issues and perspectives related to implementing them into infectious disease diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Bacterial Persistence as a Phenotypic Switch
Balaban, N. Q., Merrin, J., Chait, R., Kowalik, L., & Leibler, S. (2004) · Science · doi:10.1126/science.1099390 · Cited by 2,952 · cited 1×
“Microfluidics is an attractive approach for susceptibility testing by providing a miniaturized fluidic environment suitable for monitoring cell growth in the presence of antibiotics (Balaban et al. , 2004, Orit and Nathalie, 2009).”
BackgroundTeh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
How antibiotics kill bacteria: from targets to networks
Kohanski, M. A., Dwyer, D. J., & Collins, J. J. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2333 · Cited by 2,258
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770 · cited 1×
“Digital PCR enables direct quantification of nucleic acids through parallel single-molecule amplification (Vogelstein and Kinzler, 1999).”
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Array-Based Electrical Detection of DNA with Nanoparticle Probes
Park, S.-J., Taton, T. A., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.1067003 · Cited by 1,515
Self-citationAn Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Chemical Amplification: Continuous-Flow PCR on a Chip
Kopp, M. U., Mello, A. J. D., & Manz, A. (1998) · Science · doi:10.1126/science.280.5366.1046 · Cited by 1,212
Ultrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Yang, S., & Rothman, R. E. (2004) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(04)01044-8 · Cited by 1,112
Self-citationRecent Advances in the Polymerase Chain Reaction
Erlich, H. A., Gelfand, D., & Sninsky, J. J. (1991) · Science · doi:10.1126/science.2047872 · Cited by 1,077
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Multiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559-570.2000 · Cited by 964
Multiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559 · Cited by 961
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Purification and Characterization of PCR-Inhibitory Components in Blood Cells
Al-Soud, W. A., & Rådström, P. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.2.485-493.2001 · Cited by 944
Chip integrated strategies for acoustic separation and manipulation of cells and particles
Laurell, T., Petersson, F., & Nilsson, A. (2007) · Chem. Soc. Rev. · doi:10.1039/b601326k · Cited by 874
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Magnetic bead handling on-chip: new opportunities for analytical applications
Gijs, M. A. M. (2004) · Microfluidics and Nanofluidics · doi:10.1007/s10404-004-0010-y · Cited by 749
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T. (2007) · Analytical Chemistry · doi:10.1021/ac070444e · Cited by 649
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Requirements for high impact diagnostics in the developing world
Urdea, M., Penny, L. A., Olmsted, S. S., Giovanni, M. Y., Kaspar, P., Shepherd, A., Wilson, P., Dahl, C. A., Buchsbaum, S., Moeller, G., et al. (2006) · Nature · doi:10.1038/nature05448 · Cited by 594
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability
Easley, C. J., Karlinsey, J. M., Bienvenue, J. M., Legendre, L. A., Roper, M. G., Feldman, S. H., Hughes, M. A., Hewlett, E. L., Merkel, T. J., Ferrance, J. P., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604663103 · Cited by 547
Continuous sorting of magnetic cells via on-chip free-flow magnetophoresis
Pamme, N., & Wilhelm, C. (2006) · Lab on a Chip · doi:10.1039/b604542a · Cited by 497
Dielectrophoretic Concentration and Separation of Live and Dead Bacteria in an Array of Insulators
Lapizco-Encinas, B. H., Simmons, B. A., Cummings, E. B., & Fintschenko, Y. (2004) · Analytical Chemistry · doi:10.1021/ac034804j · Cited by 483
A nanoliter-scale nucleic acid processor with parallel architecture
Hong, J. W., Studer, V., Hang, G., Anderson, W. F., & Quake, S. R. (2004) · Nature Biotechnology · doi:10.1038/nbt951 · Cited by 470
Microdroplet-based PCR enrichment for large-scale targeted sequencing
Tewhey, R., Warner, J. B., Nakano, M., Libby, B., Medkova, M., David, P. H., Kotsopoulos, S. K., Samuels, M. L., Hutchison, J. B., Larson, J. W., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1583 · Cited by 454 · cited 1×
“…amplification and quantification in millions of droplets have been demonstrated for large scale genomic sequencing (Kiss et al. , 2008, Mazutis et al. , 2009a, Tewhey et al. , 2009) and digital detection of pathogenic E. coli O157 cells in a high background of normal K12 cells (Zeng et al. , 2010).”
Pre-PCR Processing : Strategies to Generate PCR-Compatible Samples
Rådström, P., Knutsson, R., Wolffs, P., Lövenklev, M., & Löfström, C. (2004) · Molecular Biotechnology · doi:10.1385/mb:26:2:133 · Cited by 452
Isolation and pure culture of a freshwater magnetic spirillum in chemically defined medium
Blakemore, R. P., Maratea, D., & Wolfe, R. S. (1979) · Journal of Bacteriology · doi:10.1128/jb.140.2.720-729.1979 · Cited by 449
Boedicker, J. Q., Li, L., Kline, T. R., & Ismagilov, R. F. (2008) · Lab on a Chip · doi:10.1039/b804911d · Cited by 438
Zhang, C., & Xing, D. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm389 · Cited by 417
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Molecular methods for the assessment of bacterial viability
Keer, J. T., & Birch, L. (2003) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(03)00025-3 · Cited by 394
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Driving Forces for DNA Adsorption to Silica in Perchlorate Solutions
Melzak, K. A., Sherwood, C. S., Turner, R. F. B., & Haynes, C. A. (1996) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1996.0421 · Cited by 369
On-Chip, Real-Time, Single-Copy Polymerase Chain Reaction in Picoliter Droplets
Beer, N. R., Hindson, B. J., Wheeler, E. K., Hall, S. B., Rose, K. A., Kennedy, I. M., & Colston, B. W. (2007) · Analytical Chemistry · doi:10.1021/ac701809w · Cited by 358
On-chip manipulation of free droplets
Velev, O. D., Prevo, B. G., & Bhatt, K. H. (2003) · Nature · doi:10.1038/426515a · Cited by 354
Microfluidic Single-Cell mRNA Isolation and Analysis
Marcus, J. S., Anderson, W. F., & Quake, S. R. (2006) · Analytical Chemistry · doi:10.1021/ac0519460 · Cited by 351
Microchip-Based Purification of DNA from Biological Samples
Breadmore, M. C., Wolfe, K. A., Arcibal, I. G., Leung, W. K., Dickson, D., Giordano, B. C., Power, M. E., Ferrance, J. P., Feldman, S. H., Norris, P. M., et al. (2003) · Analytical Chemistry · doi:10.1021/ac0204855 · Cited by 351
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Cheng, J., Sheldon, E. L., Wu, L., Uribe, A., Gerrue, L. O., Carrino, J., Heller, M. J., & O'Connell, J. P. (1998) · Nature Biotechnology · doi:10.1038/nbt0698-541 · Cited by 347
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
High-Throughput Quantitative Polymerase Chain Reaction in Picoliter Droplets
Kiss, M. M., Ortoleva-Donnelly, L., Beer, N. R., Warner, J., Bailey, C. G., Colston, B. W., Rothberg, J. M., Link, D. R., & Leamon, J. H. (2008) · Analytical Chemistry · doi:10.1021/ac801276c · Cited by 326
Kell, A. J., Stewart, G., Ryan, S., Peytavi, R., Boissinot, M., Huletsky, A., Bergeron, M. G., & Simard, B. (2008) · ACS Nano · doi:10.1021/nn700183g · Cited by 320
The importance of being persistent: heterogeneity of bacterial populations under antibiotic stress
Gefen, O., & Balaban, N. Q. (2009) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2008.00156.x · Cited by 315
One-step pathogen specific DNA extraction from whole blood on a centrifugal microfluidic device
Cho, Y.-K., Lee, J.-G., Park, J.-M., Lee, B.-S., Lee, Y., & Ko, C. (2007) · Lab on a Chip · doi:10.1039/b616115d · Cited by 312
Schilling, E. A., Kamholz, A. E., & Yager, P. (2002) · Analytical Chemistry · doi:10.1021/ac015640e · Cited by 299
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
Lagally, E. T., Emrich, C. A., & Mathies, R. A. (2001) · Lab on a Chip · doi:10.1039/b109031n · Cited by 284
Noninvasive Acoustic Cell Trapping in a Microfluidic Perfusion System for Online Bioassays
Evander, M., Johansson, L., Lilliehorn, T., Piskur, J., Lindvall, M., Johansson, S., Almqvist, M., Laurell, T., & Nilsson, J. (2007) · Analytical Chemistry · doi:10.1021/ac061576v · Cited by 281
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2530 · Cited by 276
A Miniature Analytical Instrument for Nucleic Acids Based on Micromachined Silicon Reaction Chambers
Northrup, M. A., Benett, B., Hadley, D. R., Landre, P., Lehew, S., Richards, J. M., & Stratton, P. (1998) · Analytical Chemistry · doi:10.1021/ac970486a · Cited by 266
Soft inertial microfluidics for high throughput separation of bacteria from human blood cells
Wu, Z., Willing, B., Bjerketorp, J., Jansson, J. K., & Hjort, K. (2009) · Lab on a Chip · doi:10.1039/b817611f · Cited by 263
Mazutis, L., Araghi, A. F., Miller, O. J., Baret, J.-C., Frenz, L., Janoshazi, A., Taly, V., Miller, B. J., Hutchison, J. B., Link, D., et al. (2009) · Analytical Chemistry · doi:10.1021/ac900403z · Cited by 263
Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation
Carlo, D. D., Jeong, K.-H., & Lee, L. P. (2003) · Lab on a Chip · doi:10.1039/b305162e · Cited by 246
Application of Polymerase Chain Reaction to the Diagnosis of Infectious Diseases
Relman, D. A. (1999) · Clinical Infectious Diseases · doi:10.1086/598618 · Cited by 241
High-Performance Single Cell Genetic Analysis Using Microfluidic Emulsion Generator Arrays
Zeng, Y., Novak, R., Shuga, J., Smith, M. T., & Mathies, R. A. (2010) · Analytical Chemistry · doi:10.1021/ac902683t · Cited by 232
A miniature integrated device for automated multistep genetic assays
Anderson, R. C. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e60 · Cited by 227
Nucleic acid purification using microfabricated silicon structures
Cady, N. C., Stelick, S., & Batt, C. A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00123-4 · Cited by 220
Catching bird flu in a droplet
Pipper, J., Inoue, M., Ng, L. F.-P., Neuzil, P., Zhang, Y., & Novak, L. (2007) · Nature Medicine · doi:10.1038/nm1634 · Cited by 218
Self-citationYang, S., Lin, S., Kelen, G. D., Quinn, T. C., Dick, J. D., Gaydos, C. A., & Rothman, R. E. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.9.3449-3454.2002 · Cited by 218
Self-citationOn-Chip Single-Copy Real-Time Reverse-Transcription PCR in Isolated Picoliter Droplets
Beer, N. R., Wheeler, E. K., Lee-Houghton, L., Watkins, N., Nasarabadi, S., Hebert, N., Leung, P., Arnold, D. W., Bailey, C. G., & Colston, B. W. (2008) · Analytical Chemistry · doi:10.1021/ac800048k · Cited by 209
Ultra fast miniaturized real-time PCR: 40 cycles in less than six minutes
Neuzil, P. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkl416 · Cited by 205
Parallel Picoliter RT-PCR Assays Using Microfluidics
Marcus, J. S., Anderson, W. F., & Quake, S. R. (2006) · Analytical Chemistry · doi:10.1021/ac0513865 · Cited by 185
Mahalanabis, M., Al-Muayad, H., Kulinski, M. D., Altman, D., & Klapperich, C. M. (2009) · Lab on a Chip · doi:10.1039/b905065p · Cited by 178
Lee, J.-G., Cheong, K. H., Huh, N., Kim, S., Choi, J.-W., & Ko, C. (2006) · Lab on a Chip · doi:10.1039/b515876a · Cited by 176
Rapid pathogen detection using a microchip PCR array instrument
Belgrader, P., Benett, W. J., Hadley, D. R., Long, G. W., Mariella, R. P., Milanovich, F. P., Nasarabadi, S., Nelson, W., Richards, J. B., & Stratton, P. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.10.2191 · Cited by 172
A Minisonicator To Rapidly Disrupt Bacterial Spores for DNA Analysis
Belgrader, P., Hansford, D., Kovacs, G. T. A., Venkateswaran, K., Mariella, Milanovich, F., Nasarabadi, S., Okuzumi, M., Pourahmadi, F., & Northrup, M. A. (1999) · Analytical Chemistry · doi:10.1021/ac990347o · Cited by 170
Legendre, L. A., Bienvenue, J. M., Roper, M. G., Ferrance, J. P., & Landers, J. P. (2006) · Analytical Chemistry · doi:10.1021/ac0516988 · Cited by 165
Advances in Polymerase Chain Reaction on Microfluidic Chips
Roper, M. G., Easley, C. J., & Landers, J. P. (2005) · Analytical Chemistry · doi:10.1021/ac050756m · Cited by 158
Antimicrobial Susceptibility Testing Using High Surface-to-Volume Ratio Microchannels
Chen, C. H., Lu, Y., Sin, M. L. Y., Mach, K. E., Zhang, D. D., Gau, V., Liao, J. C., & Wong, P. K. (2010) · Analytical Chemistry · doi:10.1021/ac9022764 · Cited by 151
Cell lysis on a microfluidic CD (compact disc)
Kim, J.-T., Jang, S. H., Jia, G., Zoval, J. V., Silva, N. A. D., & Madou, M. J. (2004) · Lab on a Chip · doi:10.1039/b401106f · Cited by 151
A DNA biochip for on-the-spot multiplexed pathogen identification
Yeung, S. W., Lee, T. M. H., Cai, H. N., & Hsing, I. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkl702 · Cited by 134
Hashimoto, M., Barany, F., & Soper, S. A. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.014 · Cited by 132
Clockwork PCR Including Sample Preparation
Pipper, J., Zhang, Y., Neužil, P., & Hsieh, T. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200705016 · Cited by 126
Self-citationSample preparation: the weak link in microfluidics-based biodetection
Mariella, R. P. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9190-7 · Cited by 122
A simple device using magnetic transportation for droplet-based PCR
Ohashi, T., Kuyama, H., Hanafusa, N., & Togawa, Y. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9078-y · Cited by 110
Nichols, J. H. (2007) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2007.07.003 · Cited by 108
Hataoka, Y., Zhang, L., Mori, Y., Tomita, N., Notomi, T., & Baba, Y. (2004) · Analytical Chemistry · doi:10.1021/ac035032u · Cited by 98
Easley, C. J., Karlinsey, J. M., & Landers, J. P. (2006) · Lab on a Chip · doi:10.1039/b600039h · Cited by 84
Electrochemical Real-Time Polymerase Chain Reaction
Yeung, S. S. W., Lee, T. M. H., & Hsing, I. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065733j · Cited by 83
Electrochemistry-Based Real-Time PCR on a Microchip
Yeung, S. S. W., Lee, T. M. H., & Hsing, I. (2007) · Analytical Chemistry · doi:10.1021/ac071198+ · Cited by 81
Kaigala, G. V., Huskins, R. J., Preiksaitis, J. K., Pang, X., Pilarski, L. M., & Backhouse, C. (2006) · Electrophoresis · doi:10.1002/elps.200600061 · Cited by 67
Micropillar array chip for integrated white blood cell isolation and PCR
Panaro, N. J., Lou, X. J., Fortina, P. M., et al. (2005) · Biomolecular Engineering · doi:10.1016/j.bioeng.2004.11.001 · Cited by 67
A unified platform for optoelectrowetting and optoelectronic tweezers
Valley, J. K., NingPei, S., Jamshidi, A., et al. (2011) · Lab on a Chip · doi:10.1039/c0lc00568a · Cited by 64
Alternating Current Electrokinetic Motion of Colloidal Particles on Interdigitated Microelectrodes
Park, S., & Beşkök, A. (2008) · Analytical Chemistry · doi:10.1021/ac7024859 · Cited by 53
Self-citationDNA methylation analysis on a droplet-in-oil PCR array
Zhang, Y., Bailey, V. J., Puleo, C., Easwaran, H., Griffiths, E. A., Herman, J. G., Baylin, S. B., & Wang, T. (2009) · Lab on a Chip · doi:10.1039/b821780g · Cited by 45
Self-citationRothman, R. E., Ramachandran, P., Yang, S. S., Hardick, A., Won, H. H., Kecojević, A., Quianzon, C. C. L., Hsieh, Y., & Gaydos, C. A. (2010) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2010.00790.x · Cited by 37
Self-citationRatchet-induced anisotropic behavior of superparamagnetic microdroplet
Zhang, J., Cheng, Z., Zheng, Y., & Jiang, L. (2009) · Applied Physics Letters · doi:10.1063/1.3103250 · Cited by 35
On chip sorting of bacterial cells using sugar-encapsulated magnetic nanoparticles
Shih, P.-H., Shiu, J.-Y., Lin, P., Lin, C., Veres, T., & Chen, P. (2008) · Journal of Applied Physics · doi:10.1063/1.2834720 · Cited by 29
Silicon microstructure arrays for DNA extraction by solid phase sample contacting at high flow rates
West, J. J., Martin, B., Jadhav, A., & Clancy, E. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.04.022 · Cited by 21
Clinical Applications of the Polymerase Chain Reaction: An Update
Cuchacovich, R. (2006) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2006.09.003 · Cited by 16
Cited by
Antibiotic resistance-the need for global solutions
Laxminarayan, R., Duse, A., Wattal, C., Zaidi, A. K. M., Wertheim, H. F. L., Sumpradit, N., Vlieghe, E., Hara, G. L., Gould, I. M., Goossens, H., et al. (2013) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70318-9 · Cited by 4,439
Ultrasensitive and visual detection of SARS-CoV-2 using all-in-one dual CRISPR-Cas12a assay
Ding, X., Yin, K., Li, Z., Lalla, R. V., Ballesteros, E., Sfeir, M. M., & Liu, C. (2020) · Nature Communications · doi:10.1038/s41467-020-18575-6 · Cited by 919
Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Craw, P., & Balachandran, W. (2012) · Lab on a Chip · doi:10.1039/c2lc40100b · Cited by 766
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Metadata
- Authors
- Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S.
- Venue
- Biotechnology Advances
- Publisher
- Elsevier BV
- Published
- 2011-11
- Volume
- 29
- Issue
- 6
- Pages
- 830-839
- ISSN
- 0734-9750 (ISSN-L)
- OpenAlex
- W2053185702
- Cited by
- 299
- References
- 104
- FWCI
- 13.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.