Cited by 133Luminescence and Fluorescent MaterialsMolecular Sensors and Ion DetectionLuminescence Properties of Advanced Materials

Molecular engineering of AIE luminogens for NIR-II/IIb bioimaging and surgical navigation of lymph nodes

Open access
Song, Shanliang, Wang, Yajun, Zhao, Yue, Huang, Wenbin, Zhang, Fei, Zhu, Shoujun, Wu, Qian, Fu, Shuang +2 more·2022·Matter

Integrity signals

Registry

Crossref · 10.1016/j.matt.2022.06.030

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Compared with ICG, NIR-920 NPs possessed advantages such as longer emission wavelength, higher SNR, and better photostability, and could be applied to long-term monitoring and tracking of deep tissues.

    “Compared with ICG, NIR-920 NPs possessed advantages such as longer emission wavelength, higher SNR, and better photostability, and could be applied to long-term monitoring and tracking of deep tissues.”
  • In the 4T1 transplanted tumor mouse model, NIR-920 NPs achieved maximum accumulation in the brachial and thoracic lymph nodes 8 h after intratumoral injection.

    “In the 4T1 transplanted tumor mouse model, NIR-920 NPs achieved maximum accumulation in the brachial and thoracic lymph nodes 8 h after intratumoral injection.”
  • Wang et al. developed the NIR-II AIE probe NIR-920 via atomic substitution for bioimaging and surgical navigation.

    “Wang et al. successfully developed a NIR-II AIE probe (NIR-920) via atomic substitution, for bioimaging and surgical navigation (Fig. 17a)126.”
  • NIR-920 exhibited maximum absorption at 920 nm, red-shifted compared to previously reported AIEgens, and its emission extended beyond 1600 nm.

    “Notably, NIR-920 exhibited a maximum absorption at 920 nm, which was red-shifted compared to previously reported aggregation-induced emission luminogens (AIEgens), and its emission extended beyond 1600 nm.”
  • NIR-920 NPs enabled precise lymph node localization and facilitated NIR-II fluorescence imaging-guided lymph node resection.

    “Benefiting from this distinct lymphnode enrichment capability, NIR-920 NPs enabled precise lymph node localization and facilitated NIR-II fluorescence imaging-guided lymph node resection.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Song, S., Wang, Y., Zhao, Y., Huang, W., Zhang, F., Zhu, S., Wu, Q., Fu, S., Tang, B. Z., & Wang, D.
Affiliations
  • Shenzhen University (CN)
  • Jilin University (CN)
  • Harbin Institute of Technology (CN)
  • Chinese University of Hong Kong (HK)
Corresponding author
  • Zhu, Shoujun
  • Tang, Ben Zhong
  • Wang, Dong
Venue
Matter
Publisher
Elsevier BV
Published
2022-09
Volume
5
Issue
9
Pages
2847-2863
ISSN
2590-2385 (ISSN-L)
OpenAlex
W4284708168
Cited by
133
References
51
Citations by year
2026: 28 · 2025: 29 · 2024: 35 · 2023: 34 · 2022: 7
FWCI
7.38
Type
journal article
Language
en
Open access
Locations
  • Matter (publishedVersion)
  • Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
Funders
  • National Natural Science Foundation of China (22175120, 52122317)
  • Shenzhen University
  • Natural Science Foundation of Guangdong Province for Distinguished Young Scholars (2020B1515020011)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence Properties of Advanced Materials
Keywords
aggregation-induced emission, sentinel lymph node imaging, lymph node imaging, surgical navigation, molecular engineering, nanoparticles, indocyanine green, photostability, penetration depth, tumor staging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review