Challenges of continuum robots in clinical context: a review
Open accessThe DOI matches its Crossref record; 156 of the 156 references it cites were found in a registry or an index.
Abstract
With the maturity of surgical robotic systems based on traditional rigid-link principles, the rate of progress slowed as limits of size and controllable degrees of freedom were reached. Continuum robots came with the potential to deliver a step change in the next generation of medical devices, by providing better access, safer interactions and making new procedures possible. Over the last few years, several continuum robotic systems have been launched commercially and have been increasingly adopted in hospitals. Despite the clear progress achieved, continuum robots still suffer from design complexity hindering their dexterity and scalability. Recent advances in actuation methods have looked to address this issue, offering alternatives to commonly employed approaches. Additionally, continuum structures introduce significant complexity in modelling, sensing, control and fabrication; topics which are of particular focus in the robotics community. It is, therefore, the aim of the presented work to highlight the pertinent areas of active research and to discuss the challenges to be addressed before the potential of continuum robots as medical devices may be fully realised.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., & Jemal, A. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21551 · Cited by 20,160
Isidori, A. (1989) · Springer eBooks · doi:10.1007/978-3-662-02581-9 · Cited by 7,869
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825
Corke, P., Roberts, J., Cunningham, J., & Hainsworth, D. (2008) · Springer Handbook of Robotics · doi:10.1007/978-3-540-30301-5_50 · Cited by 3,543
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Robotics: modelling, planning and control
(2009) · Choice Reviews Online · doi:10.5860/choice.46-6226 · Cited by 2,479
Small-scale soft-bodied robot with multimodal locomotion
Hu, W., Lum, G. Z., Mastrangeli, M., & Sitti, M. (2018) · Nature · doi:10.1038/nature25443 · Cited by 2,372
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Printing ferromagnetic domains for untethered fast-transforming soft materials
Kim, Y., Yuk, H., Zhao, R., Chester, S. A., & Zhao, X. (2018) · Nature · doi:10.1038/s41586-018-0185-0 · Cited by 2,183
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Direct Ink Writing of 3D Functional Materials
Lewis, J. A. (2006) · Advanced Functional Materials · doi:10.1002/adfm.200600434 · Cited by 1,740 · cited 2×
“Robust DIW processes require a high nozzle-particle diameter ratio or a low loading fraction to achieve reliable deposition [210].”
BackgroundSoft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Printing soft matter in three dimensions
Truby, R. L., & Lewis, J. A. (2016) · Nature · doi:10.1038/nature21003 · Cited by 1,622
Pneumatic Networks for Soft Robotics that Actuate Rapidly
Mosadegh, B., Polygerinos, P., Keplinger, C., Wennstedt, S., Shepherd, R. F., Gupta, U., Shim, J., Bertoldi, K., Walsh, C. J., & Whitesides, G. M. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303288 · Cited by 1,607
Continuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Gastric cancer: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up
Smyth, E. C., Verheij, M., Allum, W., Cunningham, D., Cervantes, A., & Arnold, D. (2016) · Annals of Oncology · doi:10.1093/annonc/mdw350 · Cited by 1,555
ACG Clinical Guideline: Diagnosis and Management of Barrett’s Esophagus
Shaheen, N. J., Falk, G. W., Iyer, P. G., & Gerson, L. B. (2016) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.322 · Cited by 1,501
Ilievski, F., Mazzeo, A. D., Shepherd, R. F., Chen, X., & Whitesides, G. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006464 · Cited by 1,381
Ferromagnetic soft continuum robots
Kim, Y., Parada, G. A., Liu, S., & Zhao, X. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7329 · Cited by 1,312
Gastric cancer: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up
Okines, A., Verheij, M., Allum, W., Cunningham, D., & Cervantes, A. (2010) · Annals of Oncology · doi:10.1093/annonc/mdq164 · Cited by 1,300
Functional Magnetic Resonance Imaging
(2014) · Encyclopedia of Criminal Justice Ethics · doi:10.4135/9781452274102.n135 · Cited by 1,225
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
Voxelated soft matter via multimaterial multinozzle 3D printing
Skylar-Scott, M. A., Mueller, J., Visser, C. W., & Lewis, J. A. (2019) · Nature · doi:10.1038/s41586-019-1736-8 · Cited by 1,024
A soft robot that navigates its environment through growth
Hawkes, E. W., Blumenschein, L. H., Greer, J. D., & Okamura, A. M. (2017) · Science Robotics · doi:10.1126/scirobotics.aan3028 · Cited by 968
3D printing of soft robotic systems
Wallin, T. J., Pikul, J., & Shepherd, R. F. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0002-2 · Cited by 942
Whitesides, G. M. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201800907 · Cited by 850
Review of emerging surgical robotic technology
Peters, B. S., Armijo, P. R., Krause, C., Choudhury, S. A., & Oleynikov, D. (2018) · Surgical Endoscopy · doi:10.1007/s00464-018-6079-2 · Cited by 740
Robotic Tentacles with Three‐Dimensional Mobility Based on Flexible Elastomers
Martinez, R. V., Branch, J. L., Fish, C. R., Jin, L., Shepherd, R. F., Nunes, R. M. D., Suo, Z., & Whitesides, G. M. (2013) · Advanced Materials · doi:10.1002/adma.201203002 · Cited by 718
Millimeter-scale flexible robots with programmable three-dimensional magnetization and motions
Xu, T., Zhang, J., Salehizadeh, M., Onaizah, O., & Diller, E. (2019) · Science Robotics · doi:10.1126/scirobotics.aav4494 · Cited by 696
Abbott, J. J., Peyer, K. E., Lagomarsino, M. C., Zhang, L., Dong, L., Kaliakatsos, I. K., & Nelson, B. J. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909341658 · Cited by 680
Statics and Dynamics of Continuum Robots With General Tendon Routing and External Loading
Rucker, D. C., & Webster III, R. J. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2160469 · Cited by 669
Shape-programmable magnetic soft matter
Lum, G. Z., Ye, Z., Dong, X., Marvi, H., Erin, O., Hu, W., & Sitti, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608193113 · Cited by 650
A Recipe for Soft Fluidic Elastomer Robots
Marchese, A. D., Katzschmann, R. K., & Rus, D. (2015) · Soft Robotics · doi:10.1089/soro.2014.0022 · Cited by 649
Soft micromachines with programmable motility and morphology
Huang, H.-W., Sakar, M. S., Petruska, A. J., Pané, S., & Nelson, B. J. (2016) · Nature Communications · doi:10.1038/ncomms12263 · Cited by 649
Control Strategies for Soft Robotic Manipulators: A Survey
George Thuruthel, T., Ansari, Y., Falotico, E., & Laschi, C. (2018) · Soft Robotics · doi:10.1089/soro.2017.0007 · Cited by 645
Nonholonomic Modeling of Needle Steering
Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065388 · Cited by 633
Soft Manipulators and Grippers: A Review
Hughes, J., Culha, U., Giardina, F., Guenther, F., Rosendo, A., & Iida, F. (2016) · Frontiers in Robotics and AI · doi:10.3389/frobt.2016.00069 · Cited by 619
Soft Somatosensitive Actuators via Embedded 3D Printing
Truby, R. L., Wehner, M., Grosskopf, A. K., Vogt, D. M., Uzel, S. G. M., Wood, R. J., & Lewis, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201706383 · Cited by 586
Multi-functional soft-bodied jellyfish-like swimming
Ren, Z., Hu, W., Dong, X., & Sitti, M. (2019) · Nature Communications · doi:10.1038/s41467-019-10549-7 · Cited by 586
Pneumatic artificial muscles: actuators for robotics and automation
Daerden, F. W., & Lefeber, D. (2002) · Cited by 576
Mechanics of hard-magnetic soft materials
Zhao, R., Kim, Y., Chester, S. A., Sharma, P., & Zhao, X. (2019) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2018.10.008 · Cited by 563
Programming magnetic anisotropy in polymeric microactuators
Kim, J., Chung, S. E., Choi, S.-E., Lee, H., Kim, J., & Kwon, S. (2011) · Nature Materials · doi:10.1038/nmat3090 · Cited by 556
Cianchetti, M., Ranzani, T., Gerboni, G., Nanayakkara, T., Althoefer, K., Dasgupta, P., & Menciassi, A. (2014) · Soft Robotics · doi:10.1089/soro.2014.0001 · Cited by 544
Nonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
Mechanical Programming of Soft Actuators by Varying Fiber Angle
Connolly, F., Polygerinos, P., Walsh, C. J., & Bertoldi, K. (2015) · Soft Robotics · doi:10.1089/soro.2015.0001 · Cited by 522
Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and Applications
Franz, A. M., Haidegger, T., Birkfellner, W., Cleary, K., Peters, T. M., & Maier-Hein, L. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2321777 · Cited by 504
Yesin, K. B., Vollmers, K., & Nelson, B. J. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065389 · Cited by 465
Open versus laparoscopic cholecystectomy in acute cholecystitis. Systematic review and meta-analysis
Coccolini, F., Catena, F., Pisano, M., Gheza, F., Fagiuoli, S., Di Saverio, S., Leandro, G., Montori, G., Ceresoli, M., Corbella, D., et al. (2015) · International Journal of Surgery · doi:10.1016/j.ijsu.2015.04.083 · Cited by 452
A Novel Layer Jamming Mechanism With Tunable Stiffness Capability for Minimally Invasive Surgery
Kim, Y.-J., Cheng, S., Kim, S., & Iagnemma, K. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2013.2256313 · Cited by 428
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Real-time dynamics of soft and continuum robots based on Cosserat rod models
Till, J., Aloi, V., & Rucker, C. (2019) · The International Journal of Robotics Research · doi:10.1177/0278364919842269 · Cited by 419
Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope
Yim, S., & Sitti, M. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2163861 · Cited by 400
A review of robotics in surgery
Davies, B. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535309 · Cited by 370
A bioinspired soft manipulator for minimally invasive surgery
Ranzani, T., Gerboni, G., Cianchetti, M., & Menciassi, A. (2015) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/10/3/035008 · Cited by 341
Design, kinematics, and control of a soft spatial fluidic elastomer manipulator
Marchese, A. D., & Rus, D. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915587925 · Cited by 330
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Buckling of Elastomeric Beams Enables Actuation of Soft Machines
Yang, D., Mosadegh, B., Ainla, A., Lee, B., Khashai, F., Suo, Z., Bertoldi, K., & Whitesides, G. M. (2015) · Advanced Materials · doi:10.1002/adma.201503188 · Cited by 316
Jeon, S., Hoshiar, A. K., Kim, K., Lee, S., Kim, E., Lee, S., Kim, J.-Y., Nelson, B. J., Cha, H.-J., Yi, B.-J., et al. (2019) · Soft Robotics · doi:10.1089/soro.2018.0019 · Cited by 301
Self-citationApplying a flexible microactuator to robotic mechanisms
(1992) · IEEE Control Systems · doi:10.1109/37.120448 · Cited by 300
Three-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2269836 · Cited by 281
van der Schaaf, I., Algra, A., Wermer, M., Molyneux, A., Clarke, M. J., van Gijn, J., & Rinkel, G. J. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003085.pub2 · Cited by 279
Martel, S., Felfoul, O., Mathieu, J.-B., Chanu, A., Tamaz, S., Mohammadi, M., Mankiewicz, M., & Tabatabaei, N. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364908104855 · Cited by 271
Curvature, Torsion, and Force Sensing in Continuum Robots Using Helically Wrapped FBG Sensors
Xu, R., Yurkewich, A., & Patel, R. V. (2016) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2016.2530867 · Cited by 268
Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions
Park, Y.-L., Elayaperumal, S., Daniel, B., Ryu, S. C., Shin, M., Savall, J., Black, R. J., Moslehi, B., & Cutkosky, M. R. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2080360 · Cited by 266
3D printing antagonistic systems of artificial muscle using projection stereolithography
Peele, B. N., Wallin, T. J., Zhao, H., & Shepherd, R. F. (2015) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/10/5/055003 · Cited by 265
Stiffness Control of Surgical Continuum Manipulators
Mahvash, M., & Dupont, P. E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2105410 · Cited by 265
Mathieu, J.-B., Beaudoin, G., & Martel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862570 · Cited by 248
Continuously distributed magnetization profile for millimeter-scale elastomeric undulatory swimming
Diller, E., Zhuang, J., Zhan Lum, G., Edwards, M. R., & Sitti, M. (2014) · Applied Physics Letters · doi:10.1063/1.4874306 · Cited by 245
Design and implementation of a multi-section continuum robot: Air-Octor
McMahan, W., Jones, B. A., & Walker, I. D. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545487 · Cited by 240
Della Santina, C., Bicchi, A., & Rus, D. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2967269 · Cited by 232
Grazioso, S., Di Gironimo, G., & Siciliano, B. (2019) · Soft Robotics · doi:10.1089/soro.2018.0047 · Cited by 230
Visual Servoing of Soft Robot Manipulator in Constrained Environments With an Adaptive Controller
Wang, H., Yang, B., Liu, Y., Chen, W., Liang, X., & Pfeifer, R. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2613410 · Cited by 207
Concentric Tube Robots: The State of the Art and Future Directions
Gilbert, H. B., Rucker, D. C., & Webster III, R. J. (2016) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-319-28872-7_15 · Cited by 197
Soft Machines That are Resistant to Puncture and That Self Seal
Shepherd, R. F., Stokes, A. A., Nunes, R. M. D., & Whitesides, G. M. (2013) · Advanced Materials · doi:10.1002/adma.201303175 · Cited by 196
Model-Free Control for Continuum Robots Based on an Adaptive Kalman Filter
Li, M., Kang, R., Branson, D. T., & Dai, J. S. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2775663 · Cited by 195
Magnetic control of continuum devices
Edelmann, J., Petruska, A. J., & Nelson, B. J. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916683443 · Cited by 194
Continuum Robot Stiffness Under External Loads and Prescribed Tendon Displacements
Oliver-Butler, K., Till, J., & Rucker, C. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2885923 · Cited by 193
Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery
Chautems, C., Tonazzini, A., Boehler, Q., Jeong, S. H., Floreano, D., & Nelson, B. J. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.201900086 · Cited by 193
Doglietto, F., Prevedello, D. M., Jane, J. A., Han, J., & Laws, E. R. (2005) · Neurosurgical Focus · doi:10.3171/foc.2005.19.6.4 · Cited by 192
Hybrid motion/force control of multi-backbone continuum robots
Bajo, A., & Simaan, N. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915584806 · Cited by 190
Bretl, T., & McCarthy, Z. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364912473169 · Cited by 184
Steerable catheters for minimally invasive surgery: a review and future directions
Hu, X., Chen, A., Luo, Y., Zhang, C., & Zhang, E. (2018) · Computer Assisted Surgery · doi:10.1080/24699322.2018.1526972 · Cited by 184
Simaan, N., Yasin, R. M., & Wang, L. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-104956 · Cited by 182
Series pneumatic artificial muscles (sPAMs) and application to a soft continuum robot
Greer, J. D., Morimoto, T. K., Okamura, A. M., & Hawkes, E. W. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989648 · Cited by 181
3D printed soft actuators for a legged robot capable of navigating unstructured terrain
Drotman, D., Jadhav, S., Karimi, M., de Zonia, P., & Tolley, M. T. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989652 · Cited by 175
Son, D., Yim, S., & Sitti, M. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2488361 · Cited by 172
Six-degree-of-freedom magnetic actuation for wireless microrobotics
Diller, E., Giltinan, J., Lum, G. Z., Ye, Z., & Sitti, M. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915583539 · Cited by 169
Taddese, A. Z., Slawinski, P. R., Pirotta, M., Momi, E. D., Obstein, K. L., & Valdastri, P. (2018) · The International Journal of Robotics Research · doi:10.1177/0278364918779132 · Cited by 169
Self-citationCarpi, F., & Pappone, C. (2009) · Expert Review of Medical Devices · doi:10.1586/erd.09.32 · Cited by 166
Autonomous robotic intracardiac catheter navigation using haptic vision
Fagogenis, G., Mencattelli, M., Machaidze, Z., Rosa, B., Price, K., Wu, F., Weixler, V., Saeed, M., Mayer, J. E., & Dupont, P. E. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw1977 · Cited by 161
Learning Closed Loop Kinematic Controllers for Continuum Manipulators in Unstructured Environments
Thuruthel, T. G., Falotico, E., Manti, M., Pratesi, A., Cianchetti, M., & Laschi, C. (2017) · Soft Robotics · doi:10.1089/soro.2016.0051 · Cited by 154
Robot-assisted Fenestrated Endovascular Aneurysm Repair (FEVAR) Using the Magellan System
Riga, C. V., Bicknell, C. D., Rolls, A., Cheshire, N. J. W., & Hamady, M. (2013) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2012.10.006 · Cited by 152
First-in-human, robotic-assisted neuroendovascular intervention
Mendes Pereira, V., Cancelliere, N. M., Nicholson, P., Radovanovic, I., Drake, K. E., Sungur, J.-M., Krings, T., & Turk, A. (2020) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2019-015671.rep · Cited by 151
Dynamic Control of the Bionic Handling Assistant
Falkenhahn, V., Hildebrandt, A., Neumann, R., & Sawodny, O. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2605820 · Cited by 149
A review on recent advances in soft surgical robots for endoscopic applications
Gifari, M. W., Beidokhti, H. N., Stramigioli, S., & Abayazid, M. (2019) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2010 · Cited by 145
Intelligent magnetic manipulation for gastrointestinal ultrasound
Norton, J., Slawinski, P. R., Lay, H. S., Martin, J., Cox, B. F., Cummins, G., Desmulliez, M. P. Y., Clutton, R. E., Obstein, K. L., Cochran, S., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aav7725 · Cited by 143
Self-citationCalderón, A. A., Ugalde, J. C., Zagal, J. C., & Pérez-Arancibia, N. O. (2016) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2016.7866293 · Cited by 142
Control Oriented Modeling of Soft Robots: The Polynomial Curvature Case
Santina, C. D., & Rus, D. L. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2955936 · Cited by 141
A Soft Pneumatic Inchworm Double balloon (SPID) for colonoscopy
Manfredi, L., Capoccia, E., Ciuti, G., & Cuschieri, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-47320-3 · Cited by 124
A soft multi-module manipulator with variable stiffness for minimally invasive surgery
Falco, I. D., Cianchetti, M., & Menciassi, A. (2017) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aa7ccd · Cited by 122
Adaptive Neural Network Control of a Compact Bionic Handling Arm
Melingui, A., Lakhal, O., Daâchi, B., Mbede, J. B., & Merzouki, R. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2396114 · Cited by 119
Heunis, C. M., Sikorski, J., & Misra, S. (2018) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2787784 · Cited by 119
A Highly Articulated Robotic Surgical System for Minimally Invasive Surgery
Ota, T., Degani, A., SCHWARTZMAN, D. S., Zubiate, B., McGarvey, J. R., Choset, H., & Zenati, M. A. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.10.026 · Cited by 117
Bynum, S. A., Davis, J. L., Green, B. L., & Katz, R. V. (2012) · American Journal of Health Promotion · doi:10.4278/ajhp.110113-quan-20 · Cited by 111
MiniMag: A Hemispherical Electromagnetic System for 5-DOF Wireless Micromanipulation
Kratochvil, B. E., Kummer, M. P., Erni, S., Borer, R., Frutiger, D. R., Schuerle, S., & Nelson, B. J. (2013) · Springer tracts in advanced robotics · doi:10.1007/978-3-642-28572-1_22 · Cited by 105
Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study
Hendrick, R. J., Mitchell, C. R., Herrell, S. D., & Webster, R. J., III (2015) · The International Journal of Robotics Research · doi:10.1177/0278364915585397 · Cited by 105
Tendon and pressure actuation for a bio-inspired manipulator based on an antagonistic principle
Maghooa, F., Stilli, A., Noh, Y., Althoefer, K. A., & Wurdemann, H. A. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139542 · Cited by 104
de Moura, D. T. H., Aihara, H., Jirapinyo, P., et al. (2019) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2019.03.016 · Cited by 103
Steerable Catheters in Cardiology: Classifying Steerability and Assessing Future Challenges
Ali, A., Plettenburg, D. H., & Breedveld, P. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2525785 · Cited by 101
Azizi, A., Tremblay, C. C., Gagné, K., & Martel, S. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7342 · Cited by 98
Truby, R. L., Katzschmann, R. K., Lewis, J. A., & Rus, D. L. (2019) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft.2019.8722722 · Cited by 95
Guiding Elastic Rods With a Robot-Manipulated Magnet for Medical Applications
Kratchman, L. B., Bruns, T. L., Abbott, J. J., & Webster, R. J., III (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2623339 · Cited by 92
Diffusion Tractography in Deep Brain Stimulation Surgery: A Review
Calabrese, E. (2016) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2016.00045 · Cited by 87
A variable stiffness catheter controlled with an external magnetic field
Chautems, C., Tonazzini, A., Floreano, D., & Nelson, B. J. (2017) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8202155 · Cited by 85
Continuum Arm Robotic Manipulator: A Review
Singh, P. K., & Krishna, C. M. (2014) · Universal Journal of Mechanical Engineering · doi:10.13189/ujme.2014.020603 · Cited by 84
Optimizing curvature sensor placement for fast, accurate shape sensing of continuum robots
Kim, B., Ha, J., Park, F. C., & Dupont, P. E. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907649 · Cited by 78
Naturally compliant robot-arms actuated by McKibben artificial muscles
Tondu, B., Boitier, V., & Lòpez, P. (2002) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1994.400269 · Cited by 77
Real-time three-dimensional flexible needle tracking using two-dimensional ultrasound
Vrooijink, G. J., Abayazid, M., & Misra, S. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630797 · Cited by 76
Development of a compact continuum tubular robotic system for nasopharyngeal biopsy
Wu, L., Song, S., Wu, K., Lim, C. M., & Ren, H. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1514-9 · Cited by 76
Runge, G. B., Wiese, M., Günther, L., & Raatz, A. (2017) · International Conference on Control, Automation and Robotics (ICCAR) · doi:10.1109/iccar.2017.7942652 · Cited by 73
Modeling and bonding-free fabrication of flexible fluidic microactuators with a bending motion
Gorissen, B., Vincentie, W., Al‐Bender, F., Reynaerts, D., & Volder, M. F. L. D. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/4/045012 · Cited by 71
An Experimental Feasibility Study on Robotic Endonasal Telesurgery
Wirz, R., Torres, L. G., Swaney, P. J., Gilbert, H. B., Alterovitz, R., Webster, R. J., III, Weaver, K. D., & Russell, P. T. (2015) · Neurosurgery · doi:10.1227/neu.0000000000000623 · Cited by 70
Bio-Inspired Octopus Robot Based on Novel Soft Fluidic Actuator
Fraś, J., Noh, Y., Maciaś, M., Wurdemann, H. A., & Althoefer, K. A. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460629 · Cited by 64
Magnetic needle guidance for neurosurgery: Initial design and proof of concept
Petruska, A. J., Ruetz, F., Hong, A., Regli, L., Sürücü, O., Zemmar, A., & Nelson, B. J. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487638 · Cited by 63
Jiang, H., Wang, Z., Liu, X., Chen, X., Jin, Y., You, X., & Chen, X. (2017) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2017.7989727 · Cited by 63
Toward Transoral Peripheral Lung Access: Combining Continuum Robots and Steerable Needles
Swaney, P. J., Mahoney, A. W., Hartley, B. I., Remirez, A. A., Lamers, E. P., Feins, R. H., Alterovitz, R., & Webster, R. J., III (2016) · Journal of Medical Robotics Research · doi:10.1142/s2424905x17500015 · Cited by 58
3D path planning for flexible needle steering in neurosurgery
Hong, A., Boehler, Q., Moser, R., Zemmar, A., Stieglitz, L. H., & Nelson, B. J. (2019) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1998 · Cited by 58
Rama, D. F., Estrada, A., Shachar, J., Castrejón, S. C., Doiny, D., Ortega, M., Gang, E. S., & Merino, J. L. (2013) · Journal of Visualized Experiments · doi:10.3791/3658 · Cited by 53
Helical actuation on a soft inflated robot body
Blumenschein, L. H., Usevitch, N. S., Do, B. H., Hawkes, E. W., & Okamura, A. M. (2018) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft.2018.8404927 · Cited by 53
Three-Degree-of-Freedom MR-Compatible Multisegment Cardiac Catheter Steering Mechanism
Ataollahi, A., Karim, R., Fallah, A. S., Rhode, K., Razavi, R., Seneviratne, L. D., Schaeffter, T., & Althoefer, K. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2276739 · Cited by 50
Simultaneous catheter and environment modeling for Trans-catheter Aortic Valve Implantation
Shi, C., Giannarou, S., Su-Lin, L., & Yang, G. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6942832 · Cited by 49
Gafford, J. B., Webster, S., Dillon, N. P., Blum, E., Hendrick, R. J., Maldonado, F., Gillaspie, E. A., Rickman, O. B., Herrell, S. D., & Webster, R. J., III (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02325-x · Cited by 49
4D interventional device reconstruction from biplane fluoroscopy
Wagner, M., Schafer, S., Strother, C., & Mistretta, C. (2016) · Medical Physics · doi:10.1118/1.4941950 · Cited by 48
Dual-Continuum Design Approach for Intuitive and Low-Cost Upper Gastrointestinal Endoscopy
Garbin, N., Wang, L., Chandler, J. H., Obstein, K. L., Simaan, N., & Valdastri, P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2881717 · Cited by 47
Self-citationSNAKE-LIKE ROBOTS FOR MINIMALLY INVASIVE, SINGLE-PORT, AND INTRALUMINAL SURGERIES
Orekhov, A. L., Abah, C., & Simaan, N. (2018) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789813232266_0008 · Cited by 46
Wu, X., Housden, R. J., Ma, Y., Razavi, B., Rhode, K., & Rueckert, D. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2360988 · Cited by 44
Endonasal Skull Base Tumor Removal Using Concentric Tube Continuum Robots: A Phantom Study
Gilbert, H. B., Webster, R. J., III, Russell, P. T., Weaver, K. D., & Swaney, P. J. (2014) · Journal of Neurological Surgery Part B Skull Base · doi:10.1055/s-0034-1390401 · Cited by 44
Chan, J. Y. K., Wong, E. W. Y., Tsang, R. K. Y., Holsinger, F. C., Tong, M. C. F., Chiu, P. W. Y., & Ng, S. S. M. (2017) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-017-4729-y · Cited by 44
Functional Magnetic Resonance Imaging
(2005) · Springer eBooks · doi:10.1007/3-540-29623-9_7101 · Cited by 43
Gong, W., Cai, J., Wang, Z., Chen, A., Ye, X., Li, H., & Zhao, Q. (2016) · Journal of Thoracic Disease · doi:10.21037/jtd.2016.02.67 · Cited by 42
Robotic-Assisted Needle Steering Around Anatomical Obstacles Using Notched Steerable Needles
Khadem, M., Rossa, C., Usmani, N., Sloboda, R. S., & Tavakoli, M. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2780192 · Cited by 41
Haga, Y., Muyari, Y., Mineta, T., Matsunaga, T., AKAHORI, H., & Esashi, M. (2005) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2005.1548439 · Cited by 38
A MEMS-based pneumatic micro-conveyor for planar micromanipulation
Yahiaoui, R., Zeggari, R., Malapert, J., & Manceau, J. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2011.04.005 · Cited by 38
Mahoney, A. W., Bruns, T. L., Swaney, P. J., & Webster, R. J., III (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487646 · Cited by 38
A Platform for Gastric Cancer Screening in Low- and Middle-Income Countries
Caprara, R. J., Obstein, K. L., Scozzarro, G., Natali, C. D., Beccani, M., Morgan, D. R., & Valdastri, P. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2386309 · Cited by 36
Self-citationSadati, S. M. H., Shiva, A., Herzig, N., Rucker, D. C., Häuser, H., Walker, I. D., Bergeles, C., Althoefer, K. A., & Nanayakkara, T. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2972790 · Cited by 35
Soft Pneumatic Artificial Muscles With Low Threshold Pressures for a Cardiac Compression Device
Obiajulu, S. C., Roche, E. T., Pigula, F. A., & Walsh, C. J. (2013) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2013-13004 · Cited by 33
Nanofiber-reinforced soft fluidic micro-actuators
Sinatra, N. R., Ranzani, T., Vlassak, J. J., Parker, K. K., & Wood, R. J. (2018) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aab373 · Cited by 33
Deep learning-based monocular placental pose estimation: towards collaborative robotics in fetoscopy
Ahmad, M. A., Ourak, M., Gruijthuijsen, C., Deprest, J. A., Vercauteren, T. K., & Poorten, E. V. (2020) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-020-02166-3 · Cited by 33
Characterization of three-dimensional steering for helical swimmers
Xu, T., Hwang, G., Andreff, N., & Régnier, S. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907544 · Cited by 25
Campisano, F., Gramuglia, F., Dawson, I. R., Lyne, C. T., Izmaylov, M. L., Misra, S., Momi, E. D., Morgan, D. R., Obstein, K. L., & Valdastri, P. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2673852 · Cited by 24
Self-citationVessel-based registration of an optical shape sensing catheter for MR navigation
Mandal, K., Parent, F., Martel, S. M., Kashyap, R., & Kadoury, S. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1366-7 · Cited by 22
3D Catheter Shape Reconstruction Using Electromagnetic and Image Sensors
Tran, P. T., Chang, P.-L., Praetere, H. D., Maes, J., Reynaerts, D., Sloten, J. V., Stoyanov, D. V., & Poorten, E. V. (2017) · Journal of Medical Robotics Research · doi:10.1142/s2424905x17400098 · Cited by 22
A Reconfigurable Variable Stiffness Manipulator by a Sliding Layer Mechanism
Li, D. C. F., Wang, Z., Ouyang, B., & Liu, Y. (2019) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2019.8793571 · Cited by 17
Aerosol Jet Printing for the Manufacture of Soft Robotic Devices
Wilkinson, N. J., Lukic-Mann, M., Shuttleworth, M. P., Kay, R. W., & Harris, R. A. (2019) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft.2019.8722766 · Cited by 14
Self-citationA Compression Valve for Sanitary Control of Fluid-Driven Actuators
Caló, S., Chandler, J. H., Campisano, F., Obstein, K. L., & Valdastri, P. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2960308 · Cited by 12
Self-citation
Cited by
Model-Based Control of Soft Robots: A Survey of the State of the Art and Open Challenges
Della Santina, C., Duriez, C., & Rus, D. (2023) · IEEE Control Systems · doi:10.1109/mcs.2023.3253419 · Cited by 402
Russo, M., Sadati, S. M. H., Dong, X., Mohammad, A., Walker, I. D., Bergeles, C., Xu, K., & Axinte, D. A. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200367 · Cited by 263
Metadata
- Authors
- da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P.
- Venue
- Progress in Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 2020-08-03
- Volume
- 2
- Issue
- 3
- Pages
- 032003
- ISSN
- 2516-1091 (ISSN-L)
- OpenAlex
- W3037426978
- Cited by
- 280
- References
- 156
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.