Cited by 330Neuroendocrine regulation and behaviorNeuropeptides and Animal PhysiologyStress Responses and Cortisol

Evaluation of enzyme immunoassay and radioimmunoassay methods for the measurement of plasma oxytocin

Open access
Szeto, Angela, McCabe, Philip M., Nation, Daniel A., Tabak, Benjamin A., Rossetti, Maria A., McCullough, Michael E., Schneiderman, Neil, Mendez, Armando J.·2011·Psychosomatic Medicine

Abstract

OBJECTIVE: There is increased interest in measuring peripheral oxytocin levels to better understand the role of this peptide in mammalian behavior, physiology, and disease. The purpose of this study was to compare methods for plasma oxytocin measurement using a commercially available enzyme immunoassay (EIA) and radioimmunoassay (RIA), to evaluate the need for sample extraction, and to assess the immunospecificity of the assays. METHODS: Oxytocin was measured in extracted and unextracted human plasma samples (n = 39). Oxytocin and its degradation products were separated by high-performance liquid chromatography and gel filtration chromatography and then assayed by EIA or RIA to identify oxytocin immunoreactive peaks. RESULTS: Without extraction, plasma measured by EIA was more than 100-fold higher than in extracted plasma, and the correlation between oxytocin levels in extracted and unextracted plasma was minimal (Spearman ρ = -0.10, p = .54). Using the RIA, most samples (>90%) were below the level of detection with or without extraction. After chromatographic fractionation of sample extracts, multiple immunoreactive products were found to be present in addition to oxytocin, which casts doubts on the specificity of the assays. CONCLUSIONS: Changes in oxytocin levels have been reported in social and behavioral challenge studies. This study indicates that sample extraction is necessary to obtain valid assay results. Changes in oxytocin degradation products are likely to contribute to the previously observed responses in circulating oxytocin levels to behavioral and social challenge. There is a critical need for valid and reliable methods to measure oxytocin in biologic samples.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/psy.0b013e31821df0c2

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Three studies that compared ELISA oxytocin measurements of the same samples with and without extraction all found no correlations.

    “Three studies have compared ELISA oxytocin measurements of the same samples with and without extraction (69-71): all reported no correlations.”

    From Intranasal Oxytocin: Myths and Delusions (2016) · cites this paper as [71]

  • EIA performed without extraction yielded values two orders of magnitude greater than those in extracted samples and without correlation, due to the presence of multiple adjunctive immunoreactive products besides oxytocin.

    “EIA performed without extraction yielded to values that were two orders of magnitude greater than those in extracted samples (Szeto et al., 2011) and without correlation, due to the presence of multiple adjunctive immunoreactive products besides oxytocin (Szeto et al., 2011).”
  • Three studies compared measurements of oxytocin in the same samples by the same ELISA with and without extraction; Robinson et al. found approximately 8 pg/ml in extracted seal plasma versus 300 pg/ml in unextracted heparin samples or 540 pg/ml in unextracted EDTA samples with no correlation, Christensen et al. found radioimmunoassay extracted mean levels of 1.1 pg/ml and spiked levels higher by t

    “Three studies have compared measurements of oxytocin in the same samples by the same ELISA, with and without extraction 101, 116, 117. Robinson et al. 116 measured oxytocin levels in seals: in extracted samples, they found plasma levels of approximately 8 pg/ml, compared to 300 pg/ml in unextracted samples collected in heparin vacutainers or 540 pg/ml in unextracted samples collected in ethylenedi”
  • Currently, endogenous oxytocin assessment methods and interpretations of the relation between plasma oxytocin levels and corresponding central nervous system functions are still contested.

    “Currently, endogenous OT assessment methods (Szeto et al., 2011) and interpretations of the relation between plasma OT levels and corresponding central nervous system functions are still contested (Meyer-Lindenberg et al., 2011;Churchland and Winkielman, 2012).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Szeto, A., McCabe, P. M., Nation, D. A., Tabak, B. A., Rossetti, M. A., McCullough, M. E., Schneiderman, N., & Mendez, A. J.
Affiliations
National Institutes of Health (US)
Corresponding author
Mendez, Armando J.
Venue
Psychosomatic Medicine
Published
2011-06
Volume
73
Issue
5
Pages
393-400
ISSN
0033-3174 (ISSN-L)
OpenAlex
W2060180675
Cited by
330
References
56
Citations by year
2026: 11 · 2025: 12 · 2024: 16 · 2023: 22 · 2022: 23 · 2021: 32 · 2020: 24 · 2019: 26 · 2018: 32 · 2017: 32 · 2016: 29 · 2015: 27 · 2014: 20 · 2013: 15 · 2012: 6
FWCI
19.21
Type
journal article
Language
en
Open access
Locations
  • Psychosomatic Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Heart, Lung, and Blood Institute (T32HL007426, P01HL036588, HL36588, HL-04726)
Topics
  • Social Sciences › Psychology › Social Psychology › Neuroendocrine regulation and behavior
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuropeptides and Animal Physiology
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
Keywords
plasma oxytocin, enzyme immunoassay, radioimmunoassay, assay comparison, sample extraction, immunospecificity, immunoreactive peptides, human plasma
MeSH terms
Animals, Cattle, Chromatography, Liquid, Arvicolinae, Female, Humans, Immunoenzyme Techniques, Macaca, Male, Oxytocin, Rabbits, Radioimmunoassay, Reagent Kits, Diagnostic, Sensitivity and Specificity, Mice, Rats, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review