The DOI matches its Crossref record; 104 of the 106 references it cites were found in a registry or an index.
Advances in retinal prosthesis systems
Open accessAbstract
Retinal prosthesis systems have undergone significant advances in the past quarter century, resulting in the development of several different novel surgical and engineering approaches. Encouraging results have demonstrated partial visual restoration, with improvement in both coarse objective function and performance of everyday tasks. To date, four systems have received marketing approval for use in Europe or the United States, with numerous others undergoing preclinical and clinical evaluation, reflecting the established safety profile of these devices for chronic implantation. This progress represents the first notion that the field of visual restorative medicine could offer blind patients a hope of real and measurable benefit. However, there are numerous complex engineering and biophysical obstacles still to be overcome, to reconcile the gap that remains between artificial and natural vision. Current developments in the form of enhanced image processing algorithms and data transfer approaches, combined with emerging nanofabrication and conductive polymerization techniques, herald an exciting and innovative future for retinal prosthetics. This review provides an update of retinal prosthetic systems currently undergoing development and clinical trials while also addressing future challenges in the field, such as the assessment of functional outcomes in ultra-low vision and strategies for tackling existing hardware and software constraints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to the considerable distance from BCs, high current amplitudes are required for retinal stimulation, possibly leading to damage due to overstimulation [35,61].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [61]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A model of saliency-based visual attention for rapid scene analysis
Itti, L., Christof Koch, A., & Niebur, E. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.730558 · Cited by 11,289
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schulze-Bonsel, K., Feltgen, N., Burau, H., Hansen, L. L., & Bach, M. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0981 · Cited by 1,001
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 891
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
MacLaren, R. E., Groppe, M., Barnard, A. R., Cottriall, C. L., Tolmachova, T., Seymour, L., Clark, K. R., During, M. J., Cremers, F. P. M., Black, G. C. M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62117-0 · Cited by 796
da Cruz, L., Fynes, K., Georgiadis, O., Kerby, J., Luo, Y. H.-L., Ahmado, A., Vernon, A. J., Daniels, J. T., Nommiste, B., Hasan, S. M., et al. (2018) · Nature Biotechnology · doi:10.1038/nbt.4114 · Cited by 730
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Liew, G., Michaelides, M., & Bunce, C. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004015 · Cited by 663
Jacobson, S. G. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2011.298 · Cited by 639
DISTURBANCES OF VISION BY CEREBRAL LESIONS
Holmes, G. (1918) · British Journal of Ophthalmology · doi:10.1136/bjo.2.7.353 · Cited by 552
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 512
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 430
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
Rizzo, J. F., Wyatt, J. L., Loewenstein, J. I., Kelly, S. K., & Shire, D. B. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.02-0819 · Cited by 362
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Five-year safety and performance results from the argus II retinal prosthesis system clinical trial.
da Cruz, L., Dorn, J. D., Humayun, M. S., Dagnelie, G., Handa, J., Barale, P.-O., Sahel, J.-A., Stanga, P. E., Hafezi, F., Safran, A. B., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.06.049 · Cited by 359
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T. I., Mathieson, K., Huie, P., Harris, J. S., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 341
Elmannai, W., & Elleithy, K. (2017) · Sensors · doi:10.3390/s17030565 · Cited by 338
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
The estimated prevalence and incidence of late stage age related macular degeneration in the UK
Owen, C. G., Jarrar, Z. A., Wormald, R., Cook, D. G., FLETCHER, A. E., & Rudnicka, A. R. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-301109 · Cited by 318
A fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
Maya‐Vetencourt, J. F., Ghezzi, D., Antognazza, M. R., Colombo, E., Mete, M., Feyen, P., Desii, A., Buschiazzo, A., Paolo, M. D., Marco, S. D., et al. (2017) · Nature Materials · doi:10.1038/nmat4874 · Cited by 294
Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind
Ho, A. C., Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Handa, J. T., Barale, P. O., Sahel, J., Stanga, P. E., Hafezi, F., et al. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.04.032 · Cited by 262
Schwartz, S. D., Tan, G. S. W., Hosseini, H., & Nagiel, A. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18681 · Cited by 253
Preservation of ganglion cell layer neurons in age-related macular degeneration.
Medeiros, N. E., & Curcio, C. A. (2001) · PubMed · Cited by 224
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., et al. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6836 · Cited by 216
Relationship between vision impairment and ability to perform activities of daily living
Haymes, S. A., JOHNSTON, A. W., & Heyes, A. D. (2002) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2002.00016.x · Cited by 206
Stingl, K., Schippert, R., Bartz-Schmidt, K. U., Besch, D., Cottriall, C. L., Edwards, T. L., Gekeler, F., Greppmaier, U., Kiel, K., Koitschev, A., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00445 · Cited by 198
Fighting Blindness with Microelectronics
Zrenner, E. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007399 · Cited by 192
Visual function and subjective quality of life compared in subjects with acquired macular disease.
Hazel, C. A., Petre, K. L., Armstrong, R. A., Benson, M. T., & Frost, N. A. (2000) · PubMed · Cited by 189
Facial Recognition Using Simulated Prosthetic Pixelized Vision
Thompson, R. W., Barnett, G. D., Humayun, M. S., & Dagnelie, G. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-0341 · Cited by 180
Dorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T. (2013) · JAMA Ophthalmology · doi:10.1001/2013.jamaophthalmol.221 · Cited by 177
Traditional Measures of Mobility Performance and Retinitis Pigmentosa
Geruschat, D. R., Turano, K. A., & STAHL, J. W. (1998) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1998.tb05087.x · Cited by 170
Visually Guided Performance of Simple Tasks Using Simulated Prosthetic Vision
Hayes, J. S., Yin, V. T., Piyathaisere, D. V., Weiland, J. D., Humayun, M. S., & Dagnelie, G. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07309.x · Cited by 164
Stimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wächtler, T. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 162
Roessler, G. F., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B. A. E., Goertz, M., Koch, C., Krisch, I., Sellhaus, B., Trieu, H. K., et al. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2752 · Cited by 161
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
Photovoltaic retinal prosthesis: implant fabrication and performance
Wang, L., Mathieson, K., Kamins, T. I., Loudin, J., Galambos, L., Goetz, G. A., Sher, A., Mandel, Y., Huie, P., Lavinsky, D., et al. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046014 · Cited by 142
Real and virtual mobility performance in simulated prosthetic vision
Dagnelie, G., Keane, P. A., Narla, V., Yang, L., Weiland, J. D., & Humayun, M. S. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s11 · Cited by 136
Mandel, Y., Goetz, G. A., Lavinsky, D., Huie, P., Mathieson, K., Wang, L., Kamins, T. I., Galambos, L., Manivanh, R. V., Harris, J. S., et al. (2013) · Nature Communications · doi:10.1038/ncomms2980 · Cited by 131
Neuroprotective Effect of Subretinal Implants in the RCS Rat
Pardue, M. T., Phillips, M. J., Yin, H., Sippy, B. D., Webb-Wood, S., Chow, A. Y., & Ball, S. L. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0515 · Cited by 119
Sommerhalder, J., Rappaz, B., de Haller, R., Fornos, A. P., Safran, A. B., & Pelizzone, M. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.017 · Cited by 116
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Update on Retinal Prosthetic Research: The Boston Retinal Implant Project
Rizzo, J. F. (2011) · Journal of Neuro-Ophthalmology · doi:10.1097/wno.0b013e31821eb79e · Cited by 111
Szlyk, J. P. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150055009 · Cited by 111
Beyeler, M., Rokem, A., Boynton, G. M., & Fine, I. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa795e · Cited by 102
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Endo, T., Hirota, M., Morimoto, T., Nishida, K., Kishima, H., Terasawa, Y., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20367 · Cited by 101
Preliminary 6 month results from the argustm ii epiretinal prosthesis feasibility study
Humayun, M. S., Dorn, J. D., Ahuja, A. K., Caspi, A., Filley, E., Dagnelie, G., Salzmann, J., Santos, A., Duncan, J., daCruz, L., et al. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5332695 · Cited by 100
Dagnelie, G., Christopher, P., Arditi, A. R., da Cruz, L., Duncan, J. L., Ho, A. C., de Koo, L. C. O., Sahel, J., Stanga, P. E., Thumann, G., et al. (2016) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12812 · Cited by 93
Tunable retina encoders for retina implants: why and how
Eckmiller, R., Neumann, D., & Baruth, O. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/011 · Cited by 88
Menzel-Severing, J., Laube, T., Brockmann, C., Bornfeld, N., Mokwa, W., Mazinani, B. A. E., Walter, P., & Roessler, G. F. (2012) · Eye · doi:10.1038/eye.2012.35 · Cited by 83
Psychophysical evaluation for visual prosthesis
Dagnelie, G. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160529 · Cited by 82
Lorach, H., Goetz, G. A., Mandel, Y., Lei, X., Kamins, T. I., Mathieson, K., Huie, P., Dalal, R., Harris, J. S., & Palanker, D. (2014) · Vision Research · doi:10.1016/j.visres.2014.09.007 · Cited by 78
Geruschat, D. R., Richards, T. P., Arditi, A., Cruz, L., Dagnelie, G., Dorn, J. D., Duncan, J. L., Ho, A. C., Olmos de koo, L. C., Sahel, J., et al. (2016) · Clinical and Experimental Optometry · doi:10.1111/cxo.12359 · Cited by 77
Potts, A. M., & Inoue, J. (1969) · PubMed · Cited by 75
FLORA™: phase I development of a functional vision assessment for prosthetic vision users
Geruschat, D. R., Flax, M., Tanna, N., Bianchi, M., Fisher, A., Goldschmidt, M., Fisher, L., Dagnelie, G., Deremeik, J., Smith, A., et al. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12242 · Cited by 75
Saliency-based image processing for retinal prostheses
Parikh, N., Itti, L., & Weiland, J. D. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/1/016006 · Cited by 70
Basic Quantitative Assessment of Visual Performance in Patients with Very Low Vision
Bach, M., Wilke, M., Wilhelm, B., Zrenner, E., & Wilke, R. G. H. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3512 · Cited by 70
Acute electrical stimulation of the human retina with an epiretinal electrode array
Keserü, M., Feucht, M., Bornfeld, N., Laube, T., Walter, P., Rößler, G., Velikay‐Parel, M., Hornig, R., & Richard, G. W. (2011) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2011.02288.x · Cited by 69
Intravitreal Injection of Normal Saline Induces Retinal Degeneration in the C57BL/6J Mouse
Hombrebueno, J. R., Luo, C., Guo, L., Chen, M., & Xu, H. (2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.2.3 · Cited by 66
Possible sources of neuroprotection following subretinal silicon chip implantation in RCS rats
Pardue, M. T., Phillips, M. J., Yin, H., Fernandes, A., Cheng, Y. C., Chow, A. Y., & Ball, S. L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/006 · Cited by 62
Chow, A. Y., Bittner, A. K., & Pardue, M. T. (2010) · PubMed Central · Cited by 60
The appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60
Simulating prosthetic vision: II. Measuring functional capacity
Chen, S. C., Suaning, G. J., Morley, J. W., & Lovell, N. H. (2009) · Vision Research · doi:10.1016/j.visres.2009.07.003 · Cited by 59
Saunders, A. L., Williams, C. E., Heriot, W. J., Briggs, R., Yeoh, J., Nayagam, D. A. X., McCombe, M. F., Villalobos, J., Burns, O., Luu, C. D., et al. (2013) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12287 · Cited by 56
Retinal Prosthetics, Optogenetics, and Chemical Photoswitches
Marc, R. E., Pfeiffer, R. L., & Jones, B. W. (2014) · ACS Chemical Neuroscience · doi:10.1021/cn5001233 · Cited by 56
Safety evaluation of “retina implant alpha IMS”—a prospective clinical trial
Kitiratschky, V. B. D., Štingl, K., Wilhelm, B., Peters, T. M., Besch, D., Sachs, H. G., Gekeler, F., Bartz‐Schmidt, K. U., & Zrenner, E. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2797-x · Cited by 55
Performance of visually guided tasks using simulated prosthetic vision and saliency-based cues
Parikh, N., Itti, L., Humayun, M., & Weiland, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026017 · Cited by 54
Image Processing for a High-Resolution Optoelectronic Retinal Prosthesis
Asher, A., Segal, W. A., Baccus, S. A., Yaroslavsky, L., & Palanker, D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894828 · Cited by 52
Fornos, A. P., Sommerhalder, J., Pittard, A., Safran, A. B., & Pelizzone, M. (2008) · Vision Research · doi:10.1016/j.visres.2008.04.027 · Cited by 50
Luo, Y. H.-L., Zhong, J. J., Clemo, M., & da Cruz, L. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.07.021 · Cited by 47
Photodiode Circuits for Retinal Prostheses
Loudin, J., Cogan, S. F., Mathieson, K., Sher, A., & Palanker, D. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2144980 · Cited by 46
Development of very large electrode arrays for epiretinal stimulation (VLARS)
Waschkowski, F., Hesse, S., Rieck, A. C., Lohmann, T., Brockmann, C., Laube, T., Bornfeld, N., Thumann, G., Walter, P., Mokwa, W., et al. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-11 · Cited by 43
The Argus II prosthesis facilitates reaching and grasping tasks: a case series
Kotecha, A., Zhong, J., Stewart, D., & da Cruz, L. (2014) · BMC Ophthalmology · doi:10.1186/1471-2415-14-71 · Cited by 42
Luo, Y. H.-L., Zhong, J., & da Cruz, L. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2912-z · Cited by 39
New technologies for developing second generation retinal prostheses
Benfenati, F., & Lanzani, G. (2018) · Lab Animal · doi:10.1038/s41684-018-0003-1 · Cited by 39
Shivdasani, M. N., Sinclair, N. C., Gillespie, L. N., Petoe, M. A., Titchener, S. A., Fallon, J. B., Perera, T., Pardinas-Diaz, D., Barnes, N. M., Blamey, P. J., et al. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-21311 · Cited by 38
Safety Studies for a 44-Channel Suprachoroidal Retinal Prosthesis: A Chronic Passive Study
Abbott, C. J., Nayagam, D. A. X., Luu, C. D., Epp, S. B., Williams, R. A., Rosa, C. M. S.-L., Villalobos, J., McGowan, C. C., Shivdasani, M. N., Burns, O., et al. (2018) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.17-23086 · Cited by 38
Grating Acuity and Contrast Tests for Clinical Trials of Severe Vision Loss
Bittner, A. K., Jeter, P. E., & Dagnelie, G. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182271638 · Cited by 36
Region-of-interest processing for electronic visual prostheses
Boyle, J. R., Maeder, A. J., & Boles, W. W. (2008) · Journal of Electronic Imaging · doi:10.1117/1.2841708 · Cited by 36
Implantation of modular photovoltaic subretinal prosthesis
Lee, D. Y., Lorach, H., Huie, P., & Palanker, D. (2016) · Ophthalmic Surgery, Lasers and Imaging Retina · doi:10.3928/23258160-20160126-11 · Cited by 30
Functional visual fields: relationship of visual field areas to self‐reported function
Subhi, H., Latham, K., Myint, J., & Crossland, M. D. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12362 · Cited by 29
2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)
(2021) · doi:10.1109/biocas49922.2021 · Cited by 26
Acuboost™: Enhancing the maximum acuity of the Argus II Retinal Prosthesis System
Sahel, J., Mohand‐Saïd, S., Stanga, P. E., Caspi, A., & Greenberg, R. J. (2013) · Investigative Ophthalmology & Visual Science · Cited by 23
Visual Perception After Long-Term Implantation of a Retinal Implant
Richard, G., Keserü, M., Feucht, M., Post, N. H., & Hornig, R. (2008) · Investigative Ophthalmology & Visual Science · Cited by 23
Petoe, M. A., McCarthy, C. D., Shivdasani, M. N., Sinclair, N. C., Scott, A. F., Ayton, L. N., Barnes, N. M., Guymer, R. H., Allen, P. J., Blamey, P. J., et al. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-21041 · Cited by 23
Development of the boston retinal prosthesis
Rizzo, J. F., Shire, D. B., Kelly, S. K., Troyk, P. R., Gingerich, M. D., McKee, B., Priplata, A. A., Chen, J., Drohan, W. A., Doyle, P., et al. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090855 · Cited by 21
Chapter 1—restoring vision to the blind: the new age of implanted visual prostheses
(2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.7.3 · Cited by 21
Jeong, J., Shin, S., Lee, G. J., Gwon, T. M., Park, J. H., & Kim, S. J. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610744 · Cited by 20
Face Detection using the Argus® II Retinal Prosthesis System
Stanga, P. E., Sahel, J., Mohand‐Saïd, S., da Cruz, L., Caspi, A., Merlini, F., & Greenberg, R. J. (2013) · Investigative Ophthalmology & Visual Science · Cited by 17
Richard, G., Feucht, M., Bornfeld, N., Laube, T., Rößler, G., Velikay‐Parel, M., & Hornig, R. (2005) · Investigative Ophthalmology & Visual Science · Cited by 17
Endo, T., Fujikado, T., Hirota, M., Kanda, H., Morimoto, T., & Nishida, K. (2018) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-018-3982-0 · Cited by 15
Long Term Tolerability of the First Wireless Implant for Electrical Epiretinal Stimulation
Keserü, M., Post, N. H., Hornig, R., Zeitz, O., & Richard, G. (2009) · Investigative Ophthalmology & Visual Science · Cited by 13
Recognition of a Virtual Scene via Simulated Prosthetic Vision
Zhao, Y., Geng, X., Li, Q., Jiang, G., Gu, Y., & Lv, X. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00058 · Cited by 8
The Development of a Picture Discrimination Test for People with Very Poor Vision
Gulati, R. R., Roche, H., Thayaparan, K., Hornig, R., & Rubin, G. S. (2011) · Investigative Ophthalmology & Visual Science · Cited by 4
A polymer-based interface restores light sensitivity in blind rats
Ghezzi, D., Rosa, A. M., Maurizio, M., Grazia, P., Guglielmo, L., & Fabio, B. (2014) · Frontiers in Neuroengineering · doi:10.3389/conf.fneng.2014.11.00002 · Cited by 1
Allen, P. J., Ayton, L. N., Yeoh, J., Briggs, R., Nayagam, D. A. X., Williams, R. A., Whitchurch, C. B., Luu, C. D., Shepherd, R. K., & Guymer, R. H. (2015) · Investigative Ophthalmology & Visual Science · Cited by 1
Laser microstructured diamond electrode arrays for bionic eye applications (Conference Presentation)
Prawer, S., & Garrett, D. J. (2018) · doi:10.1117/12.2295786 · Cited by 1
Research works printed but not linked: 29
- Medeiros NE, 2001, Invest Ophthalmol Vis Sci, 42, 795
- Foerster O., 1929, J Psychol Neurol, 39, 463
- Potts AM, 1969, Invest Ophthalmol Vis Sci, 8, 605
- Humayun MS, 2009, Conf Proc IEEE Eng Med Biol Soc, 2009, 4566
- Stanga PE, 2012, Invest Ophthalmol Vis Sci, 53, 6952
- Richard G, 2005, Invest Ophthalmol Vis Sci, 46, 1143
- Keserü M, 2009, Invest Ophthalmol Vis Sci, 50, 4226
- Richard G, 2005, Invest Ophthalmol Vis Sci, 49, 1786
- Zhou M, 2008, Conf Proc IEEE Eng Med Biol Soc, 43, 2003
- Hornig R, 2016, Artificial vision, 99
- Walter P, 2016, Artificial vision, 151
- Schloesser M, SENSORS, 1
- Rizzo JF, 2011, Conf Proc IEEE Eng Med Biol Soc, 2011, 3135
- Chow AY, 2010, Trans Am Ophthalmol Soc, 108, 120
- Zrenner E, 2016, Artificial vision, 65
- Gekeler F, 2013, Invest Ophthalmol Vis Sci, 54, 1036
- Lorach H, 2016, Artificial vision, 115
- Ayton LN, 2016, Artificial vision, 125
- Allen PJ, 2015, Invest Ophthalmol Vis Sci, 56, 750
- Fujikado T., 2016, Artificial vision, 139
- Endo T, 2018, Graefes Arch Clin Exp Ophthalmol, 48, 62
- 10.1097/00006324-199807000-00022 · DOI
- Hazel CA, 2000, Invest Ophthalmol Vis Sci, 41, 1309
- Sommerhalder J, 2016, Artificial vision, 29
- Ruben G, 2016, Artificial vision, 9
- Gulati R, 2011, Invest Ophthalmol Vis Sci, 52, 1197
- Jeong J, 2013, Conf Proc IEEE Eng Med Biol Soc, 2013, 5295
- Sahel J, 2013, Invest Ophthalmol Vis Sci, 54, 1389
- Stanga P, 2013, Invest Ophthalmol Vis Sci, 54, 1766
Cited by
Sorted by citations
Maya‐Vetencourt, J. F., Manfredi, G., Mete, M., Colombo, E., Bramini, M., Marco, S. D., Shmal, D., Mantero, G., Dipalo, M., Rocchi, A., et al. (2020) · Nature Nanotechnology · doi:10.1038/s41565-020-0696-3 · Cited by 217
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
Seo, H., Chung, W. G., Kwon, Y. W., Kim, S., Hong, Y., Park, W., Kim, E., Lee, J., Lee, S., Kim, M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00290 · Cited by 157
Chung, W. G., Jang, J., Cui, G., Lee, S., Jeong, H., Kang, H., Seo, H., Kim, E., Kim, E., Lee, J., et al. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01587-w · Cited by 118
Kim, S., Baek, S., Sluyter, R., Konstantinov, K., Kim, J. H., Kim, S., & Kim, J. H. (2023) · EcoMat · doi:10.1002/eom2.12356 · Cited by 105
Direct laser writing of 3D electrodes on flexible substrates
Brown, M. A., Zappitelli, K. M., Singh, L., Yuan, R., Bemrose, M. A., Brogden, V., Miller, D. J., Smear, M. C., Cogan, S. F., & Gardner, T. J. (2023) · Nature Communications · doi:10.1038/s41467-023-39152-7 · Cited by 90
Metadata
- Authors
- Bloch, E., Luo, Y., & da Cruz, L.
- Affiliations
- Moorfields Eye Hospital NHS Foundation Trust (GB)
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK
- Corresponding author
- Bloch, Edward
- Venue
- Therapeutic Advances in Ophthalmology
- Publisher
- SAGE Publications
- Published
- 2019-01
- Volume
- 11
- Pages
- 2515841418817501-2515841418817501
- ISSN
- 2515-8414 (ISSN-L)
- PMC
- PMC6350159
- OpenAlex
- W2909244976
- Cited by
- 201
- References
- 106
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 18 · 2023: 24 · 2022: 32 · 2021: 22 · 2020: 80 · 2019: 9
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Therapeutic Advances in Ophthalmology (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- retinal prosthesis, vision restoration, blindness, image processing algorithms, data transmission, nanofabrication, conducting polymers, functional outcome assessment, clinical trials, artificial vision
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review