Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus
Open accessAbstract
BACKGROUND: Numerous laboratory tests are used in the diagnosis and management of diabetes mellitus. The quality of the scientific evidence supporting the use of these assays varies substantially. APPROACH: An expert committee compiled evidence-based recommendations for laboratory analysis in screening, diagnosis, or monitoring of diabetes. The overall quality of the evidence and the strength of the recommendations were evaluated. The draft consensus recommendations were evaluated by invited reviewers and presented for public comment. Suggestions were incorporated as deemed appropriate by the authors (see Acknowledgments). The guidelines were reviewed by the Evidence Based Laboratory Medicine Committee and the Board of Directors of the American Association for Clinical Chemistry and by the Professional Practice Committee of the American Diabetes Association. CONTENT: Diabetes can be diagnosed by demonstrating increased concentrations of glucose in venous plasma or increased hemoglobin A1c (HbA1c) in the blood. Glycemic control is monitored by the people with diabetes measuring their own blood glucose with meters and/or with continuous interstitial glucose monitoring (CGM) devices and also by laboratory analysis of HbA1c. The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of ketones, autoantibodies, urine albumin, insulin, proinsulin, and C-peptide are addressed. SUMMARY: The guidelines provide specific recommendations based on published data or derived from expert consensus. Several analytes are found to have minimal clinical value at the present time, and measurement of them is not recommended.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
272 of 502 cited sources checked · 153 supported · 3 flagged · accuracy not yet measured
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“The decreases of HbA 1c in those using BGM were similar to the decreases in comparably treated people who did not use BGM.”
What the sources say
- Partly supportedcites [111] Malanda, 2012, Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin, Cochrane Database Syst Rev sourceExperimental — accuracy not yet measured
The Glycaemic control measured by HbA1c section reports that several studies found HbA1c improvements in both groups without a statistically significant difference. But the Subgroup analyses section reports a statistically significant 0.3-percentage-point greater decrease with self-monitoring at up to six months, so the unqualified statement that the decreases were similar overstates the review's findings. (LLM, conf=0.88)
- Supportedcites [112] Farmer, 2012, Meta-analysis of individual patient data in randomised trials of self monitoring of blood glucose in people with non-insulin treated type 2 diabetes, BMJ source
The Discussion reports HbA1c decreases of 0.88% in the self-monitoring group and 0.69% in the comparator group, supporting the description of broadly similar decreases. It also notes a small additional reduction with self-monitoring, so “similar” should not be read as “identical.” (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [113] Machry, 2018, Self-monitoring blood glucose improves glycemic control in type 2 diabetes without intensive treatment: a systematic review and meta-analysis, Diabetes Res Clin Pract source
- Disputedcites [114] Mannucci, 2018, Effects of structured versus unstructured self-monitoring of blood glucose on glucose control in patients with non-insulin-treated type 2 diabetes: a meta-analysis of randomized controlled trials, J Diabetes Sci Technol sourceExperimental — accuracy not yet measured
In “Trials Comparing SMBG with no SMBG” (p. 3), the paper reports a statistically significant greater reduction in HbA1c with self-monitoring than without it (−0.17 percentage points in the full dataset). The Discussion (p. 5) likewise calls the reduction small but significant, rather than similar between groups. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Partly supported
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“The presence of multiple islet autoantibodies (IAA, GADA, IA-2A/IA-2bA, or ZnT8A) is associated with a risk of type 1 diabetes of >90% (408,422,423).”
What the sources say
- Disputedcites [408] Ziegler, 2013, Seroconversion to multiple islet autoantibodies and risk of progression to diabetes in children, JAMA sourceExperimental — accuracy not yet measured
The Results section (Children With Multiple Islet Autoantibodies; page unavailable) confirms that multiple autoantibodies are associated with high risk, but reports progression of 69.7% at 10 years and 84.2% at 15 years—not greater than 90%. Adding ZnT8 autoantibodies did not substantially change the progression estimates in the cohorts where they were measured. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
- Disputedcites [422] Jacobsen, 2020, The risk of progression to type 1 diabetes is highly variable in individuals with multiple autoantibodies following screening, Diabetologia sourceExperimental — accuracy not yet measured
The Results (Number and type of autoantibodies; page unavailable) report five-year diabetes incidences of 29% for participants with two autoantibodies and 31% for those with more than two. The Discussion says risk varies substantially after screening and that progression was questionable for a considerable number even with more than two autoantibodies. These five-year estimates do not establish lifetime risk, but the paper does not support the unqualified >90% risk attributed to it. (LLM, conf=0.83)
Checked by a reasoning model — may be wrong.
- Partly supportedcites [423] Anand, 2021, Islet autoimmunity and HLA markers of presymptomatic and clinical type 1 diabetes: joint analyses of prospective cohort studies in Finland, Germany, Sweden, and the U.S, Diabetes Care sourceExperimental — accuracy not yet measured
The Results report a higher 15-year type 1 diabetes risk with multiple autoantibodies, but the risk exceeded 90% only in some groups: it was 92% with three autoantibodies at seroconversion, versus 85% with two. Table 2 also shows that risk varied by age at development of multiple autoantibodies. The unqualified >90% figure is therefore not supported; ZnT8A was measured but excluded from the primary analyses. (LLM, conf=0.91)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Notwithstanding this recommendation, the evidence that population screening for hyperglycemia and subsequent prevention efforts will provide long-term benefit is inconsistent (27).”
What the sources say
- Partly supportedcites [27] Nathan, 2019, Does diabetes prevention translate into reduced long-term vascular complications of diabetes?, Diabetologia sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) says evidence that diabetes prevention reduces long-term vascular complications is inconsistent. The paper assesses prevention studies, not population screening for hyperglycemia followed by prevention efforts, so it does not establish the claim for that broader strategy. (LLM, conf=0.88)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“FPG increases with increasing age beginning in the third to fourth decade (97,98).”
What the sources say
- Supportedcites [97] Tchobroutsky, 1991, Blood glucose levels in diabetic and non-diabetic subjects, Diabetologia source
In “Normal” fasting blood glucose levels, the paper states that fasting plasma glucose tends to rise with age. Table 2 shows the mean increasing from ages 20–29 to 30–39 and continuing upward in older groups, consistent with a rise beginning in the third to fourth decade. (LLM, conf=0.90)
- Supportedcites [98] van den Beld, 2018, The physiology of endocrine systems with ageing, Lancet Diabetes Endocrinol source
The Glucose homoeostasis section states that fasting plasma glucose rises by approximately 0.055 mmol/L per decade, beginning as early as the fourth decade of life. This supports the citing sentence’s description of an age-related increase beginning in the third to fourth decade. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Careful evaluation over several consecutive days in normoglycemic individuals revealed that biological variation of FPG (mean glucose of 4.9 mmol/L [88 mg/dL]) exhibited within-and between-subject CVs of 4.8% to 6.1% and 7.5% to 7.8%, respectively (90)(91)(92).”
What the sources say
- Not checked — no full text of the sourcecites [90] Widjaja, 1999, Within- and between-subject variation in commonly measured anthropometric and biochemical variables, Clin Chem source
- Partly supportedcites [91] Mooy, 1996, Intra-individual variation of glucose, specific insulin and proinsulin concentrations measured by two oral glucose tolerance tests in a general Caucasian population: the Hoorn Study, Diabetologia sourceExperimental — accuracy not yet measured
The Abstract reports test–retest variation in fasting glucose among people with normal glucose tolerance. It does not give the claimed mean of 4.9 mmol/L, the within- and between-subject CV ranges, or an evaluation over several consecutive days; searches for those figures and terms found no supporting passage. (LLM, conf=0.78)
- Not checked — no full text of the sourcecites [92] Sebastián-Gámbaro, 1997, Intra- and inter-individual biological variability data bank, Eur J Clin Chem Clin Biochem
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesThe cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Measurement of FPG in 246 normal and 80 previously undiagnosed individuals with diabetes revealed mean intraindividual CVs of 4.8% and 7.1%, respectively (91).”
What the sources say
- Could not verifycites [91] Mooy, 1996, Intra-individual variation of glucose, specific insulin and proinsulin concentrations measured by two oral glucose tolerance tests in a general Caucasian population: the Hoorn Study, Diabetologia sourceExperimental — accuracy not yet measured
The available Abstract passage discusses fasting-glucose test–retest variation in people with normal glucose tolerance, but gives no mean intraindividual CVs. Searches for 246, 80, 4.8%, and 7.1% found no passage verifying the sample sizes or the values for either group. (LLM, conf=0.72)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“Glucose homeostasis is impaired with aging.”
What the sources say
- Supportedcites [97] Tchobroutsky, 1991, Blood glucose levels in diabetic and non-diabetic subjects, Diabetologia source
The “Normal” fasting blood glucose levels section reports that fasting glucose in apparently non-diabetic subjects tends to rise with age. The “Normal” post-prandial blood glucose levels section also reports that post-meal glucose rises with age. Together, these support the broad paraphrase about age-related impairment of glucose homeostasis. (LLM, conf=0.88)
- Supportedcites [98] van den Beld, 2018, The physiology of endocrine systems with ageing, Lancet Diabetes Endocrinol source
The Glucose homoeostasis section states that glucose homoeostasis tends towards disequilibrium with increasing chronological age. It also reports gradual increases in fasting and post-challenge glucose concentrations, supporting the citing sentence’s broad paraphrase. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“For example, the meta-analysis by Farmer et al. (112) found that the mean pooled reduction in HbA 1c was 0.88% in BGMassigned groups and 0.69% in the usual care groups.”
What the sources say
- Supportedcites [112] Farmer, 2012, Meta-analysis of individual patient data in randomised trials of self monitoring of blood glucose in people with non-insulin treated type 2 diabetes, BMJ source
The Discussion reports a mean pooled HbA1c reduction of 0.88% in the self-monitoring intervention group and 0.69% in the comparator group across the trials. These are the values and groups attributed to Farmer et al. in the citing sentence. (LLM, conf=0.95)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Use of meters that meet the current ISO standard reduced the financial consequences of inaccuracy of glucose meters by more than £178 ($238) per patient-year.”
What the sources say
- Partly supportedcites [128] Fortwaengler, 2018, The financial impact of inaccurate blood glucose monitoring systems, J Diabetes Sci Technol sourceExperimental — accuracy not yet measured
The Results (page unavailable) estimate £235 less inaccuracy-related cost per patient-year for an average meter meeting ISO 15197:2013 than for one failing ISO 15197:2003, which supports a reduction greater than £178 for that comparison. But the £178 figure itself compares meters failing and meeting the older 2003 standard; the paper reports modeled cost comparisons, not an observed reduction from using compliant meters. Our copy does not report the $238 figure. (LLM, conf=0.83)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Meta-analyses also reported that, by 1 year of use of BGM, the improvements in HbA 1c seen at earlier time points were lost (111,113).”
What the sources say
- Partly supportedcites [111] Malanda, 2012, Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin, Cochrane Database Syst Rev sourceExperimental — accuracy not yet measured
The Main results report a significant HbA1c decrease at up to six months but a statistically non-significant decrease at 12 months in patients whose diabetes duration was at least one year. The Subgroup analyses also report a significant decrease at 12 months in newly diagnosed patients. The claim captures the first finding but omits that qualification and describes a non-significant result as improvements being lost. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [113] Machry, 2018, Self-monitoring blood glucose improves glycemic control in type 2 diabetes without intensive treatment: a systematic review and meta-analysis, Diabetes Res Clin Pract source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Partly supported
- It may state two separate claims as one. 120
- Probably not a substantial claim. 76
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Decrease in glucose concentration in the sample due to glycolysis is a serious and underappreciated problem (62,63).”
What the sources say
- Not checked — no full text of the sourcecites [62] Bruns, 2020, Diagnosis of gestational diabetes mellitus will be flawed until we can measure glucose, Clin Chem source
- Supportedcites [63] Bruns, 2009, Stabilization of glucose in blood samples: why it matters, Clin Chem source
In “Sources of Error in Measurements of Plasma Glucose,” the paper says glycolysis causes substantial glucose loss in blood samples, often exceeding laboratory analytical error. It also says sample handling has been little studied recently, perhaps because of a mistaken belief that sodium fluoride solved the problem. The “Diagnosis of Diabetes” section explains the serious consequence: patients may be misclassified. (LLM, conf=0.94)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Many factors participate in the metabolic dysregulation that develops with increasing age, and changes in body composition make an important contribution (100).”
What the sources say
- Supportedcites [100] Chia, 2018, Age-related changes in glucose metabolism, hyperglycemia, and cardiovascular risk, Circ Res source
The ‘Mechanisms of Glucose Dysregulation’ section says that metabolic dysregulation in aging is multifaceted and that changes in body composition leading to insulin resistance play a major role. This directly supports the paraphrase. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“FPG does not increase significantly after age 60, but 2-h glucose concentrations during a 75-g OGTT are considerably higher in older people (98,99).”
What the sources say
- Partly supportedcites [98] van den Beld, 2018, The physiology of endocrine systems with ageing, Lancet Diabetes Endocrinol sourceExperimental — accuracy not yet measured
The Glucose homoeostasis section reports that glucose concentrations two hours after a 75-g oral glucose tolerance test gradually increase with age. It does not describe that increase as considerable; it also reports that fasting plasma glucose rises by approximately 0.055 mmol/L per decade, without stating that the rise becomes statistically insignificant after age 60. No page number is available in our copy. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [99] Blunt, 1991, Evaluation of fasting plasma glucose as screening test for NIDDM in older adults. Rancho Bernardo Study, Diabetes Care source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The modeling demonstrated that increasing inaccuracy of the glucose measurements progressively increased (a) the number of severe hypoglycemic episodes over 30 days, (b) the total daily insulin use, and (c) the number of fingersticks per day.”
What the sources say
- Partly supportedcites [127] Campos-Náñez, 2017, Clinical impact of blood glucose monitoring accuracy: an in-silico study, J Diabetes Sci Technol sourceExperimental — accuracy not yet measured
The Results sections report that higher measurement error is associated with more severe hypoglycemia, and that high error rates and positive bias increase daily insulin use and fingerstick counts. The study simulated 30 days, but Table 2 reports severe hypoglycemia as events per six months, not as a count over 30 days. Its results also depend on meter bias, so they do not establish an unqualified progressive increase for every meter. (LLM, conf=0.88)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The second modeling study (128) demonstrated that meter inaccuracy increased the total cost of health care (including costs associated with hypoglycemic episodes), with the least accurate meters producing the greatest costs.”
What the sources say
- Supportedcites [128] Fortwaengler, 2018, The financial impact of inaccurate blood glucose monitoring systems, J Diabetes Sci Technol source
The Methods (Analysis) describe a model estimating total additional cost from meter inaccuracy, including severe hypoglycemic events. The Results report higher additional costs for less accurate systems, and the Discussion states that systems failing the ISO 15197:2003 accuracy criteria had the highest costs. These are modeled costs for an in silico type 1 diabetes population. (LLM, conf=0.92)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Most randomized controlled trials (RCTs) in adults with type 1 diabetes show that rt-CGM leads to lower HbA 1c (156-159) and reduced time in the hypoglycemic range (160,161).”
What the sources say
- Not checked — no full text of the sourcecites [156] Beck, 2017, Effect of continuous glucose monitoring on glycemic control in adults with type 1 diabetes using insulin injections: the DIAMOND randomized clinical trial, JAMA source
- Partly supportedcites [157] Riddlesworth, 2017, Hypoglycemic event frequency and the effect of continuous glucose monitoring in adults with type 1 diabetes using multiple daily insulin injections, Diabetes Ther sourceExperimental — accuracy not yet measured
The Introduction reports that participants randomized to CGM in the DIAMOND trial had larger A1C decreases and less time in hypoglycemic ranges than controls. This supports the outcomes for one trial, but the paper does not establish that most RCTs in adults with type 1 diabetes show both effects. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [158] Lind, 2017, Continuous glucose monitoring vs conventional therapy for glycemic control in adults with type 1 diabetes treated with multiple daily insulin injections: the GOLD randomized clinical trial, JAMA source
- Not checked — no full text of the sourcecites [159] Tamborlane, 2008, Continuous glucose monitoring and intensive treatment of type 1 diabetes, N Engl J Med source
- Supportedcites [160] Hermanns, 2014, The impact of continuous glucose monitoring on low interstitial glucose values and low blood glucose values assessed by point-of-care blood glucose meters: results of a crossover trial, J Diabetes Sci Technol source
This citation is attached to reduced time in the hypoglycemic range, not to the HbA1c claim. The Results section reports that, in adults with type 1 diabetes, the duration of hypoglycemia was significantly lower during real-time CGM than during blinded CGM. Page numbers are not provided in our copy. (LLM, conf=0.92)
- Not checked — no full text of the sourcecites [161] van Beers, 2016, Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial, Lancet Diabetes Endocrinol source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
Every source the paper cites for this claim was checked and supports it.
In the paper
“In a study of individuals under 18 years of age with type 1 diabetes, the frequency of BGM was found to correlate inversely with HbA 1c and with the incidence of diabetic ketoacidosis (151).”
What the sources say
- Supportedcites [151] Ziegler, 2011, Frequency of SMBG correlates with HbA1c and acute complications in children and adolescents with type 1 diabetes, Pediatr Diabetes source
The Patients and methods section describes a cohort of children and adolescents aged 0–18 years with type 1 diabetes. The Results report lower HbA1c with more frequent self-monitoring of blood glucose, though the association was weaker in younger children, and a significant inverse relationship between monitoring frequency and diabetic ketoacidosis. (LLM, conf=0.92)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Testing more frequently than 10 times per day was not associated with greater control of glycemia as HbA 1c levels were similar in participants testing 10 to 12 times per day and in those testing 13 or more times per day (7.8% and 7.7%, respectively).”
What the sources say
- Supportedcites [150] Miller, 2013, Evidence of a strong association between frequency of self-monitoring of blood glucose and hemoglobin A1c levels in T1D exchange clinic registry participants, Diabetes Care source
Split into 2 atoms — 2 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“A systematic review of RCTs in adults with type 1 or type 2 diabetes suggested that is-CGM may reduce HbA 1c in those with type 1 diabetes or insulin-treated type 2 diabetes (166), while another systematic review of studies (primarily in type 1 diabetes) with randomized or cohort designs suggested a small (0.26%) but statistically significant reduction in HbA 1c (167).”
What the sources say
- Not checked — no full text of the sourcecites [166] Cowart, 2020, Systematic review of randomized controlled trials evaluating glycemic efficacy and patient satisfaction of intermittent-scanned continuous glucose monitoring in patients with diabetes, Diabetes Technol Ther source
- Partly supportedcites [167] Castellana, 2020, Efficacy and safety of flash glucose monitoring in patients with type 1 and type 2 diabetes: a systematic review and meta-analysis, BMJ Open Diabetes Res Care sourceExperimental — accuracy not yet measured
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Although most RCTs have not been powered to detect reductions in the rate of severe hypoglycemia, a study in people over the age of 60 with type 1 diabetes (a population at high risk of hypoglycemia) showed significant reductions in both time in the hypoglycemic range and severe hypoglycemic events (162).”
What the sources say
- Supportedcites [162] Pratley, 2020, Effect of continuous glucose monitoring on hypoglycemia in older adults with type 1 diabetes: a randomized clinical trial, JAMA source
Split into 2 atoms — 2 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Many meters incorporate changes that eliminate or greatly ameliorate most interferences, but interferences persist (137,138).”
What the sources say
- Partly supportedcites [137] Sai, 2019, Evaluation of linearity and interference effect on SMBG and POCT devices, showing drastic high values, low values, or error messages, J Diabetes Sci Technol sourceExperimental — accuracy not yet measured
The Discussion describes newer meters with interference-detection and error-display functions, and the Conclusions report that interference-related errors still occur. The paper does not establish that many meters have such changes or that the changes eliminate or greatly ameliorate most interferences. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [138] Vanavanan, 2010, Performance of a new interference-resistant glucose meter, Clin Biochem source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Randomized controlled trials of the use of rt-CGM, compared with standard blood glucose monitoring, in adults with type 2 diabetes have generally shown reductions in HbA 1c with no significant change in time in hypoglycemia (169-172).”
What the sources say
- Not checked — no full text of the sourcecites [169] Yoo, 2008, Use of a real time continuous glucose monitoring system as a motivational device for poorly controlled type 2 diabetes, Diabetes Res Clin Pract source
- Not checked — no full text of the sourcecites [170] Ehrhardt, 2011, The effect of real-time continuous glucose monitoring on glycemic control in patients with type 2 diabetes mellitus, J Diabetes Sci Technol source
- Not checked — no full text of the sourcecites [171] Beck, 2017, Continuous glucose monitoring versus usual care in patients with type 2 diabetes receiving multiple daily insulin injections: a randomized trial, Ann Intern Med source
- Partly supportedcites [172] Martens, 2021, Effect of continuous glucose monitoring on glycemic control in patients with type 2 diabetes treated with basal insulin: a randomized clinical trial, JAMA sourceExperimental — accuracy not yet measured
The Primary and Key Secondary Outcomes section reports significantly lower HbA1c with CGM than with blood glucose meter monitoring in adults with type 2 diabetes treated with basal insulin. But the Other Glycemic Outcomes section reports exploratory reductions in time below both 54 mg/dL (P = .001) and 70 mg/dL (P = .02), rather than no significant change in time in hypoglycemia. This trial also cannot establish what trials generally found. (LLM, conf=0.91)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Prevalence of undiagnosed diabetes is markedly increased in women aged 35 to 44 years, in those with race/ethnicity other than non-Hispanic White, and those with obesity (249).”
What the sources say
- Partly supportedcites [249] Azeez, 2019, Hypertension and diabetes in non-pregnant women of reproductive age in the United States, Prev Chronic Dis sourceExperimental — accuracy not yet measured
The Results (page not supplied) report higher prevalence of undiagnosed diabetes among women in the listed racial/ethnic groups and among women with obesity. They report higher prevalence of diabetes overall at ages 35–39 and 40–44, but do not establish that undiagnosed diabetes specifically was more prevalent at those ages. (LLM, conf=0.88)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“One RCT of rt-CGM use during pregnancy in women with type 1 diabetes showed a modest but statistically significant reduction of HbA 1c in women randomized to rt-CGM compared with those randomized to continuing to use blood glucose meters, with no differences in severe hypoglycemia.”
What the sources say
- Supportedcites [184] Feig, 2017, Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes (CONCEPTT): a multicentre international randomised controlled trial, Lancet source
Split into 2 atoms — 2 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“One RCT of rt-CGM versus blood glucose monitoring in women with gestational diabetes mellitus showed no significant differences in HbA 1c or neonatal outcomes but less weight gain with CGM use (185).”
What the sources say
- Partly supportedcites [185] Wei, 2016, Effect of a CGMS and SMBG on maternal and neonatal outcomes in gestational diabetes mellitus: a randomized controlled trial, Sci Rep sourceExperimental — accuracy not yet measured
The Abstract and Results report an RCT in women with gestational diabetes: HbA1c and neonatal outcomes did not differ significantly, while the CGMS group gained significantly less weight. The Methods identify the device as a Gold Medtronic MiniMed CGMS but do not establish that the intervention was real-time CGM, so that specification is not supported by our copy. (LLM, conf=0.86)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, the increasing accuracy of the devices and at least one RCT comparing nonadjunctive to adjunctive use (191) has led the FDA to approve most current CGM devices for nonadjunctive use in the U.S.”
What the sources say
- Supportedcites [191] Aleppo, 2017, REPLACE-BG: a randomized trial comparing continuous glucose monitoring with and without routine blood glucose monitoring in adults with well-controlled type 1 diabetes, Diabetes Care source
The citation is attached to the claim that an RCT compared nonadjunctive with adjunctive CGM use. The Introduction describes that comparison, and the Conclusions report that CGM alone was noninferior to CGM with blood glucose monitoring. The subsequent statement about FDA approval of most current devices is not the part specifically attributed to this trial. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The accuracy of CGM devices has improved significantly over time, with manufacturers of current devices reporting mean absolute relative deviation (MARD) proportions of 8.1% to 12.3%, compared with 5% to 10% for current BGM devices (and 22% for the first intermittently read interstitial glucose monitor brought to market in 2001) (190).”
What the sources say
- Partly supportedcites [190] Facchinetti, 2016, Continuous glucose monitoring sensors: past, present and future algorithmic challenges, Sensors (Basel) sourceExperimental — accuracy not yet measured
Section 2, “The Past: The ‘Smart’ CGM Sensor” (page unavailable), documents improved CGM accuracy, including a reduction in one device’s MARD from 13% to 9%. Section 3 says CGM accuracy became comparable to commercial SMBG devices. The text passages do not substantiate the claimed 8.1%–12.3% CGM range, 5%–10% BGM range, or 22% figure for a monitor introduced in 2001. (LLM, conf=0.88)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Unfortunately, approximately 25% of those assigned to the 1-step group went through the 2-step process and the caregivers were not blinded to assignment of the participants.”
What the sources say
- Partly supportedcites [261] Hillier, 2021, A pragmatic, randomized clinical trial of gestational diabetes screening, N Engl J Med sourceExperimental — accuracy not yet measured
Methods (Randomization; page unavailable) states that providers could not be blinded, and Methods (Statistical Methods; page unavailable) says some participants assigned to 1-step screening received 2-step screening. Results (Trial Population; page unavailable) reports 66% adherence in the 1-step arm, but does not establish that approximately 25% specifically underwent 2-step screening. The paper describes a randomized trial, not a cohort study. (LLM, conf=0.86)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The HAPO FUS documented in both groups that risk of disorders of glucose metabolism at follow-up were associated with GDM and continuously with maternal glucose concentrations (268,269).”
What the sources say
- Partly supportedcites [268] Lowe, 2018, Association of gestational diabetes with maternal disorders of glucose metabolism and childhood adiposity, JAMA sourceExperimental — accuracy not yet measured
The ‘Gestational Diabetes Status and Maternal Outcomes’ results report that disorders of glucose metabolism at follow-up were more frequent in mothers with gestational diabetes (52.2%) than in those without it (20.1%). This paper’s child outcomes concern adiposity, not disorders of glucose metabolism, and the passages do not establish a continuous association between maternal glucose concentrations and follow-up glucose disorders in both mothers and children. No page number is available in our copy. (LLM, conf=0.86)
- Partly supportedcites [269] Lowe, 2019, Hyperglycemia and adverse pregnancy outcome follow-up study (HAPO FUS): maternal gestational diabetes mellitus and childhood glucose metabolism, Diabetes Care sourceExperimental — accuracy not yet measured
The Results (Association of Maternal GDM Status With Childhood Dichotomous Glucose Outcomes; page unavailable) report that maternal GDM was associated with impaired glucose tolerance in offspring aged 10–14, but not with impaired fasting glucose; type 2 diabetes cases were too few to analyze. This paper examines children, not outcomes in both mothers and children, and the passages found do not establish a continuous association between maternal glucose concentrations and follow-up disorders. (LLM, conf=0.86)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Although two RCTs found that treatment of GDM can reduce perinatal morbidity (264,265), it is not known whether treatment reduces long-term risks in children.”
What the sources say
- Supportedcites [264] Crowther, 2005, Effect of treatment of gestational diabetes mellitus on pregnancy outcomes, N Engl J Med source
The conclusions report that treatment of gestational diabetes reduces serious perinatal morbidity. The secondary-outcomes discussion says long-term follow-up is needed to determine whether treated children have fewer later complications. This paper is one of the two RCTs cited; it is not being cited as evidence that it conducted both trials. (LLM, conf=0.93)
- Supportedcites [265] Landon, 2009, A multicenter, randomized trial of treatment for mild gestational diabetes, N Engl J Med source
The Discussion reports that this trial reduced shoulder dystocia and fetal overgrowth and says its findings were consistent with the ACHOIS trial. It also notes that treatment did not significantly reduce the composite primary perinatal outcome, so the support concerns specific complications rather than that composite. The citations are attached to the claim about the two RCTs, not the subsequent statement about long-term risks in children. (LLM, conf=0.90)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Moreover, different glucose cutoffs for the 2-step screening were applied at the two sites.”
What the sources say
- Supportedcites [261] Hillier, 2021, A pragmatic, randomized clinical trial of gestational diabetes screening, N Engl J Med source
The Methods section (GDM Screening and Diagnosis Approaches) specifies different positive glucose challenge test cutoffs at the two sites: ≥130 mg/dL at Kaiser Permanente Northwest and ≥140 mg/dL at Kaiser Permanente Hawaii. The Discussion also identifies the differing thresholds as a limitation of the trial. (LLM, conf=0.95)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The frequency of GDM detected with the 1-step process was approximately twice that found with the 2-step process, but no significant differences in prespecified single or composite outcomes were found between the two groups.”
What the sources say
- Partly supportedcites [261] Hillier, 2021, A pragmatic, randomized clinical trial of gestational diabetes screening, N Engl J Med sourceExperimental — accuracy not yet measured
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Frequently used is the colorimetric reaction that occurs between AcAc and nitroprusside (sodium nitroferricyanide), resulting in a purple color (301).”
What the sources say
- Supportedcites [301] Brooke, 2016, Evaluation of the accuracy of capillary hydroxybutyrate measurement compared with other measurements in the diagnosis of diabetic ketoacidosis: a systematic review, Int J Environ Res Public Health source
The Discussion (section 7) says nitroprusside reacts with acetoacetate to change the test strip’s colour. The Introduction (section 1) identifies the nitroprusside test’s resulting colour as purple–violet. (LLM, conf=0.93)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Blood ketone determinations that measure bOHB specifically are useful for both diagnosis (299,301) and ongoing monitoring of DKA (298,299).”
What the sources say
- Supportedcites [299] Kilpatrick, 2022, Controversies around the measurement of blood ketones to diagnose and manage diabetic ketoacidosis, Diabetes Care source
In “Blood Ketones for the Diagnosis and Management of DKA,” the paper reports that laboratory guidelines endorse blood BOHB measurement to diagnose and monitor DKA. The same section reports guidelines recommending repeated BOHB measurements to assess response to treatment. (LLM, conf=0.90)
- Supportedcites [301] Brooke, 2016, Evaluation of the accuracy of capillary hydroxybutyrate measurement compared with other measurements in the diagnosis of diabetic ketoacidosis: a systematic review, Int J Environ Res Public Health source
The Introduction reports that blood β-OHB is recommended for diagnosis and treatment of ketoacidosis. The Conclusions support its diagnostic usefulness, while the Discussion explains that blood β-OHB falls as ketosis resolves and that urine ketones can misleadingly rise during treatment, supporting its usefulness for monitoring. The Discussion also cautions that point-of-care meters can be inaccurate at high β-OHB levels. (LLM, conf=0.86)
- Supportedcites [298] Dhatariya, 2020, Diabetic ketoacidosis, Nat Rev Dis Primers source
The Diagnosis section recommends direct measurement of blood β-hydroxybutyrate to assess ketonaemia and says its measurement can guide response to DKA treatment. These passages support its use for both diagnosis and ongoing monitoring; page numbers were not supplied. (LLM, conf=0.94)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The presence of urine ketones is highly sensitive for DKA or significant ketosis, with high negative predictive value suggesting utility in ruling out DKA (300,301).”
What the sources say
- Not checked — no full text of the sourcecites [300] Schwab, 1999, Screening for ketonemia in patients with diabetes, Ann Emerg Med source
- Partly supportedcites [301] Brooke, 2016, Evaluation of the accuracy of capillary hydroxybutyrate measurement compared with other measurements in the diagnosis of diabetic ketoacidosis: a systematic review, Int J Environ Res Public Health sourceExperimental — accuracy not yet measured
The Conclusions report high sensitivity for urine ketones in identifying DKA in the emergency department. But the Results report a urine-ketone negative predictive value of 71.84% in one study, and the Discussion notes DKA deaths in patients with negative urine-ketone tests. The source therefore does not support the claimed high negative predictive value or the suggested use of a negative test to rule out DKA. Page numbers are not available in our copy. (LLM, conf=0.88)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In addition, due to its high specificity, urine glucose is advocated by the IDF as a screening test for undiagnosed diabetes in low-resource settings where other procedures are not available (297).”
What the sources say
- Partly supportedcites [297] International Diabetes Federation Guideline Development Group, 2014, Global guideline for type 2 diabetes, Diabetes Res Clin Pract sourceExperimental — accuracy not yet measured
The guideline’s screening discussion says urine glucose has high specificity (>98%) and may have a place for detecting undiagnosed diabetes in low-resource settings where other procedures are unavailable. But it also notes low sensitivity (21–64%); “may have a place” is more cautious than saying the IDF advocates it as a screening test. (LLM, conf=0.88)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The two major mechanisms responsible for the high ketone concentrations in people with diabetes are increased production from triglycerides and decreased utilization in the liver, both a result of absolute or relative insulin deficiency and increased counterregulatory hormones including cortisol, epinephrine, glucagon, and growth hormone (298).”
What the sources say
- Partly supportedcites [298] Dhatariya, 2020, Diabetic ketoacidosis, Nat Rev Dis Primers sourceExperimental — accuracy not yet measured
Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Specifically, stringent control of HbA 1c values during pregnancy decreases congenital malformations, large-for-date infants, and the complications of pregnancy and delivery that can otherwise occur when glycemic control is not carefully managed (333).”
What the sources say
- Partly supportedcites [333] Kitzmiller, 2008, Managing preexisting diabetes for pregnancy, Diabetes Care sourceExperimental — accuracy not yet measured
The Initial evaluation section links good glycemic control to fewer oversized infants and maternal, fetal, and neonatal complications. It places the risk of congenital malformations in the first few weeks of pregnancy and recommends achieving near-normal A1C before pregnancy to prevent them. The claim omits that timing distinction, implying that stringent control at any point during pregnancy reduces malformations. (LLM, conf=0.84)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Analysis of 60 studies with 13 devices showed that most devices had negative bias (all the others had positive bias) and large standard deviations.”
What the sources say
- Supportedcites [324] Hirst, 2017, Performance of point-of-care HbA1c test devices: implications for use in clinical practice—a systematic review and meta-analysis, Clin Chem Lab Med source
The Results state that 60 studies analyzed mean bias for 13 devices; nine devices had negative mean bias and four had positive mean bias. The Clinical implications section describes the majority as having negative bias and large standard deviations. The Abstract gives a different study count (61), but the Results explicitly support the cited count of 60. (LLM, conf=0.91)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“An HbA 1c value of 6.5% (48 mmol/mol) or greater is considered diagnostic.”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The Fasting and 2-Hour Plasma Glucose section identifies an A1C diagnostic threshold of ≥6.5% (48 mmol/mol). The Confirming the Diagnosis section adds that diagnosis generally requires two abnormal test results; the claim describes the threshold, not the full confirmation procedure. (LLM, conf=0.94)
- Supportedcites [319] Selvin, 2018, Prognostic implications of single-sample confirmatory testing for undiagnosed diabetes: a prospective cohort study, Ann Intern Med source
The introduction states that 6.5% is the diagnostic HbA1c cut point, and the Methods (Diabetes Definitions) use ≥6.5% as the threshold for elevated HbA1c. The paper also notes that a diabetes diagnosis generally requires confirmatory testing; the threshold alone does not establish a confirmed diagnosis. (LLM, conf=0.88)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The role of HbA 1c in the diagnosis of diabetes was first proposed and implemented in 2009 ( 22), made possible by improved assay standardization through the NGSP (National Glycohemoglobin Standardization Program) and IFCC, and new data demonstrating the association between HbA 1c concentrations and risk for retinopathy (22).”
What the sources say
- Partly supportedcites [22] International Expert Committee, 2009, International Expert Committee report on the role of the A1c assay in the diagnosis of diabetes, Diabetes Care sourceExperimental — accuracy not yet measured
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“However, the comparator was conversion when urine ketones were negative, which is not a typical marker for resolution (308).”
What the sources say
- Partly supportedcites [308] Noyes, 2007, Hydroxybutyrate near-patient testing to evaluate a new end-point for intravenous insulin therapy in the treatment of diabetic ketoacidosis in children, Pediatr Diabetes sourceExperimental — accuracy not yet measured
The Abstract identifies the comparator as the study’s current end-point B, but it required both pH above 7.3 and ketone-free urine—not negative urine ketones alone. The Discussion supports the qualification that negative urine ketones are not a generally required marker for transition: it says guidelines allow urinary ketones to remain present and that practice varies between centres. (LLM, conf=0.86)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“HbA 1c is used as an index of mean glycemia, as a measure of risk for the development of diabetes complications, and, most importantly, to set goals of therapy for people with diabetes (295,318,327).”
What the sources say
- Supportedcites [295] Goldstein, 2004, Tests of glycemia in diabetes, Diabetes Care source
The Glycated hemoglobin testing section says GHb is used as an index of mean glycemia and a measure of risk for diabetes complications. The Standardization of GHb section says the DCCT established specific diabetes treatment goals using GHb as an index of mean blood glucose; the paper also identifies HbA1c as a form of GHb. (LLM, conf=0.94)
- Supportedcites [318] Sacks, 2011, A1c versus glucose testing: a comparison, Diabetes Care source
The A1C Measurement section says A1C represents average glucose over the preceding 8–12 weeks and predicts the risk of microvascular complications. The Perspective section says it is routinely used to monitor glycemic control and guide therapy, supporting its use in setting treatment goals. (LLM, conf=0.93)
- Not checked yetcites [327] American Diabetes Association, 2000, Implications of the diabetes control and complications trial, Diabetes Care
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In addition, a study among races showed that all measures of glycemia, including HbA 1c , fructosamine, and glycated albumin, were on average higher among Black participants compared with White participants, and that the measures were similarly associated with risk of nephropathy, retinopathy, and cardiovascular disease (CVD) in the different races (340).”
What the sources say
- Partly supportedcites [340] Parrinello, 2016, Racial differences in and prognostic value of biomarkers of hyperglycemia, Diabetes Care sourceExperimental — accuracy not yet measured
Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“One study has suggested that differences in mean red cell half-life, which may range from approximately 48 to 68 days (mean 58 days and 1 SD of 4.5 to 6.5 days), may explain some of the interindividual variability in the relationship between measured average glucose and HbA 1c levels (343).”
What the sources say
- Supportedcites [343] Malka, 2016, Mechanistic modeling of hemoglobin glycation and red blood cell kinetics enables personalized diabetes monitoring, Sci Transl Med source
The section “Measured variation in MRBC is sufficient to explain all non-glycemic variation in HbA1c” (page unavailable) reports a mean red-cell age of about 58 days with a standard deviation of 4.5–6.5 days. It also finds that variation in mean red-cell age could explain the observed glucose-independent variation in HbA1c, supporting the citing sentence’s hedged conclusion. The approximately 48–68-day range is a rough inference from the reported mean and variability, rather than a range stated verbatim. (LLM, conf=0.87)
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The NGSP reference method, which was the DCCT primary reference, is a cation-exchange HPLC method that quantifies HbA 1c and is a CLSI-designated comparison method (360).”
What the sources say
- Partly supportedcites [360] Steffes, 2005, Hemoglobin A1c measurements over nearly two decades: sustaining comparable values throughout the Diabetes Control and Complications Trial and the Epidemiology of Diabetes Interventions and Complications study, Clin Chem sourceExperimental — accuracy not yet measured
The Materials and Methods section (REFERENCE METHOD AT THE BHL; page not provided) describes the DCCT reference method as an ion-exchange HPLC assay that quantifies HbA1c. The paper also describes the BHL’s role in NGSP network monitoring, but the passages do not establish that CLSI designated the method a comparison method. (LLM, conf=0.86)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Since 1996, the NGSP, initiated under the auspices of the AACC and endorsed by the ADA, has standardized GHb test results among laboratories to DCCT-equivalent HbA 1c values (357-359) and focused on improving worldwide assay performance.”
What the sources say
- Supportedcites [357] Little, 2019, The national glycohemoglobin standardization program: over 20 years of improving hemoglobin A1c measurement, Clin Chem source
The Introduction states that the NGSP was established in 1996 to make routine HbA1c results traceable to DCCT results. The NGSP Process describes calibration to NGSP/DCCT results, while The NGSP Network says it certifies manufacturers and laboratories worldwide; Status of HbA1c Measurement identifies improved assay accuracy as an NGSP objective. (LLM, conf=0.92)
- Not checked yetcites [358] Little, 2001, The national glycohemoglobin standardization program: a five-year progress report, Clin Chem
- Not checked yetcites [359] Goldstein, 1997, Bringing order to chaos: the National Glycohemoglobin Standardization Program, Contemp Intern Med
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Most methods can be classified into groups based on assay principle (66,295,312).”
What the sources say
- Not checked yetcites [66] Rifai, 2017, Carbohydrates
- Supportedcites [295] Goldstein, 2004, Tests of glycemia in diabetes, Diabetes Care source
The “Chemistry and terminology” section states that glycated-hemoglobin assay methods can be divided into two major categories according to their assay principles: charge differences or structural characteristics. It also says most methods quantify HbA1c. (LLM, conf=0.94)
- Not checked yetcites [312] Goldstein, 1986, Glycated hemoglobin: methodologies and clinical applications, Clin Chem
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“These additional genetic factors may assist in assigning a probability of the diagnosis of type 1 diabetes of uncertain etiology, and genetic risk scores for type 1 diabetes have been developed (390).”
What the sources say
- Partly supportedcites [390] Ferrat, 2020, A combined risk score enhances prediction of type 1 diabetes among susceptible children, Nat Med sourceExperimental — accuracy not yet measured
The First Paragraph says genetic factors have been used in type 1 diabetes prediction and that combined risk factors improve the accuracy of diagnoses in adult incident cases. Extended Data Fig. 2 also describes several genetic risk scores. The paper does not show that these scores assign a probability of type 1 diabetes as the diagnosis when a patient's diabetes etiology is uncertain; its individual probability estimates concern future disease risk in children. (LLM, conf=0.83)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“However, an exception is the mutational analyses established for classification of diabetes in the neonate (381-384) as well as in young individuals with a dominant family history of diabetes, often referred to as maturityonset diabetes of the young (MODY) (384,385) (Table 8).”
What the sources say
- Supportedcites [381] Edghill, 2008, Insulin mutation screening in 1,044 patients with diabetes: mutations in the INS gene are a common cause of neonatal diabetes but a rare cause of diabetes diagnosed in childhood or adulthood, Diabetes source
The Study population section (page unavailable) describes mutation screening in patients with neonatal diabetes and in families meeting MODY criteria, including affected members across generations. The Conclusions (page unavailable) recommend INS mutation screening for diabetes diagnosed before age one and identify INS mutations as a cause of both permanent neonatal diabetes and MODY. (LLM, conf=0.88)
- Partly supportedcites [382] Støy, 2008, Diagnosis and treatment of neonatal diabetes: a United States experience, Pediatr Diabetes sourceExperimental — accuracy not yet measured
The Conclusions state that testing for genetic defects in neonatal diabetes is critical for guiding management, and the Results report genetic diagnoses in 20 of 32 patients diagnosed before six months of age. The paper describes a family with MODY-type diabetes in the Discussion (Variable phenotype), but does not establish mutational analysis as a classification method for young people with a dominant family history of diabetes. Page numbers are unavailable in our copy. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [383] Murphy, 2008, Clinical implications of a molecular genetic classification of monogenic beta-cell diabetes, Nat Clin Pract Endocrinol Metab source
- Supportedcites [384] Carlsson, 2020, Absence of islet autoantibodies and modestly raised glucose values at diabetes diagnosis should lead to testing for MODY: lessons from a 5-year pediatric Swedish National Cohort Study, Diabetes Care source
The Introduction describes MODY as dominantly inherited diabetes typically diagnosed young. The Clinical Characteristics and Details of Testing sections describe molecular genetic testing to identify and diagnose MODY. This source is cited for the MODY portion of the sentence, not the neonatal-diabetes portion. (LLM, conf=0.91)
- Not checked — no full text of the sourcecites [385] Fajans, 2001, Molecular mechanisms and clinical pathophysiology of maturity-onset diabetes of the young, N Engl J Med source
Strength:boosted· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Up to 90% of individuals with type 1 diabetes diagnosed before age 30 years have the HLA haplotypes DRB1*04-DQA1*03:01-DQB1* 03:02(DR4-DQ8), DRB1*03-DQA1*05:01-DQB1*02:01 (DR3-DQ2.5),or both (379).”
What the sources say
- Partly supportedcites [379] Graham, 2002, Genetic effects on age-dependent onset and islet cell autoantibody markers in type 1 diabetes, Diabetes sourceExperimental — accuracy not yet measured
The Discussion (page not available in our copy) discusses DQ2 and DQ8 haplotypes in patients with type 1 diabetes and relates their disease risk to age at onset. It does not report that up to 90% of people diagnosed before age 30 carry either specified DR–DQ haplotype, or both; that prevalence and age cutoff are unsupported. (LLM, conf=0.82)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Although several islet autoantibodies have been detected in individuals with type 1 diabetes, and these have prognostic value in individuals at high risk of type 1 diabetes, routine measurement of islet autoantibodies has limited use outside of clinical studies (410).”
What the sources say
- Partly supportedcites [410] Warshauer, 2020, New frontiers in the treatment of type 1 diabetes, Cell Metab sourceExperimental — accuracy not yet measured
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In children with only one persistent islet autoantibody, the risk of diabetes within 10 years is 15% while two or more islet autoantibodies predict type 1 diabetes in 70% within 10 years (408,409).”
What the sources say
- Supportedcites [408] Ziegler, 2013, Seroconversion to multiple islet autoantibodies and risk of progression to diabetes in children, JAMA source
The Results report 10-year progression of 14.5% for children with a single islet autoantibody and 69.7% for those with multiple autoantibodies, matching the rounded figures in the claim. The Methods define seroconversion using positive serial samples, supporting the claim’s reference to persistent autoantibodies. Page numbers are unavailable in our copy. (LLM, conf=0.94)
- Partly supportedcites [409] Vehik, 2020, Hierarchical order of distinct autoantibody spreading and progression to type 1 diabetes in the TEDDY study, Diabetes Care sourceExperimental — accuracy not yet measured
The Results (page unavailable) report that children who developed a second autoantibody had a higher risk of type 1 diabetes than those who remained positive for one. The Conclusions (page unavailable) likewise describe multiple autoantibodies as conferring higher risk. Neither passage gives the claimed 10-year risks of 15% and 70%; the figure caption instead identifies a five-year comparison. (LLM, conf=0.87)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“There is some evidence that early diagnosis may prevent hospitalization with ketoacidosis and preserve residual b-cells (393).”
What the sources say
- Partly supportedcites [393] Barker, 2004, Clinical characteristics of children diagnosed with type 1 diabetes through intensive screening and follow-up, Diabetes Care sourceExperimental — accuracy not yet measured
The Onset hospitalization section (page not provided) reports far fewer hospitalizations among closely followed DAISY children than community cases, and the discussion describes decreased hospitalization for DKA at onset. The Insulin dose section reports lower insulin requirements after diagnosis, but the paper does not establish that early diagnosis preserves residual beta cells. (LLM, conf=0.84)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Depending on the specific MODY mutation, the disease can be mild (e.g., glucokinase mutation) and not usually associated with long term complications of diabetes or as severe as typical type 1 diabetes (e.g., hepatocyte nuclear factor [HNF] mutations) (2).”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The Maturity-Onset Diabetes of the Young section describes GCK-MODY as mild and stable. The Diagnosis of Monogenic Diabetes section reports no complications for GCK-MODY in studies without glucose-lowering therapy, while complication risks for HNF1A- and HNF4A-MODY are similar to those in type 1 and type 2 diabetes. (LLM, conf=0.92)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Type 2 diabetes is a heterogenous polygenic disease with both resistance to the action of insulin and defective insulin secretion (4,5).”
What the sources say
- Not checked — no full text of the sourcecites [4] Reaven, 1988, Banting lecture 1988. Role of insulin resistance in human disease, Diabetes source
- Supportedcites [5] Sacks, 1996, The pathogenesis of type II diabetes mellitus. A polygenic disease, Am J Clin Pathol source
The Summary describes type II diabetes as a polygenic, heterogeneous disease involving defects in both insulin action and insulin secretion. The Review Article passage identifies decreased insulin action in peripheral tissues as insulin resistance and describes impaired insulin production as the other major defect. (LLM, conf=0.95)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“However, the risk alleles in these loci all have relatively small effects and do not significantly enhance our ability to predict the risk of type 2 diabetes (396,397).”
What the sources say
- Could not verifycites [396] Viñuela, 2020, Genetic variant effects on gene expression in human pancreatic islets and their implications for T2D, Nat Commun sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports smaller eQTL effects for variants in certain islet regulatory regions, but those are effects on gene expression, not estimates of how much the alleles change diabetes risk. The Introduction and Results (pages unavailable) discuss risk variants and their mechanisms; searches for risk-effect sizes and predictive ability found no passage assessing either part of the claim. (LLM, conf=0.74)
- Partly supportedcites [397] Meigs, 2008, Genotype score in addition to common risk factors for prediction of type 2 diabetes, N Engl J Med sourceExperimental — accuracy not yet measured
The Discussion reports small individual per-allele effects and says the 18-allele score did not substantially improve prediction beyond common phenotypic risk factors measured in adulthood. The claim omits that condition: the paper also reports modest discriminatory ability when only factors known in youth were considered. (LLM, conf=0.86)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Could not verify
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Genome-wide association studies have identified more than 30 genetic factors, which increase the risk for type 2 diabetes (394,395).”
What the sources say
- Supportedcites [394] Mahajan, 2018, Fine-mapping type 2 diabetes loci to single-variant resolution using high-density imputation and islet-specific epigenome maps, Nat Genet source
The opening section reports that GWAS had identified more than 120 loci influencing type 2 diabetes risk. The Results section (“Discovery of novel loci for T2D susceptibility”) reports 243 loci associated with type 2 diabetes at genome-wide significance, supporting the claim that more than 30 genetic factors had been identified. (LLM, conf=0.94)
- Not checked — no full text of the sourcecites [395] Mansour Aly, 2021, Genome-wide association analyses highlight etiological differences underlying newly defined subtypes of diabetes, Nat Genet source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“ICA tests measure the degree of binding of immunoglobulin to islet sections and are compared with a WHO standard serum available from the National Institute of Biological Standards and Control (437).”
What the sources say
- Supportedcites [437] Mire-Sluis, 2000, The World Health Organization International Collaborative Study for islet cell antibodies, Diabetologia source
The paper describes ICA detection by immunofluorescence binding on human pancreatic tissue sections and reports assay results relative to the proposed standard serum 97/550 (Abstract; Results). It identifies 97/550 as the WHO international standard for ICA and says the ampouled serum would be distributed by NIBSC after approval; the Discussion reports that approval was granted. (LLM, conf=0.90)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Most individuals without diabetes who have only one autoantibody will not develop type 1 diabetes, as the 10-year risk is about 15% (408).”
What the sources say
- Partly supportedcites [408] Ziegler, 2013, Seroconversion to multiple islet autoantibodies and risk of progression to diabetes in children, JAMA sourceExperimental — accuracy not yet measured
The Results section, “Children With a Single Islet Autoantibody,” reports a 14.5% risk of progression to diabetes within 10 years, supporting the approximate 15% figure and the statement that most did not progress. The study measured this risk in children, however, while the citing sentence extends it to individuals generally. (LLM, conf=0.86)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Diabetes is associated with a high rate of cardiovascular events and is also the leading cause of end-stage renal disease in the Western world (452).”
What the sources say
- Partly supportedcites [452] Thurlow, 2021, Global epidemiology of end-stage kidney disease and disparities in kidney replacement therapy, Am J Nephrol sourceExperimental — accuracy not yet measured
In the Introduction’s section on geographic variation in treated ESKD incidence (page unavailable), the review identifies diabetes as a risk factor associated with kidney disease in high-income countries, including the US and Europe. It does not say diabetes is the leading cause of end-stage kidney disease in the Western world. (LLM, conf=0.78)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Partly supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Diabetes is associated with a high rate of cardiovascular events and is also the leading cause of end-stage renal disease in the Western world (452).”
What the sources say
- Could not verifycites [452] Thurlow, 2021, Global epidemiology of end-stage kidney disease and disparities in kidney replacement therapy, Am J Nephrol sourceExperimental — accuracy not yet measured
The section on ESKD incidence in the United States discusses diabetes as a contributor to kidney-disease burden, while the section on KRT access lists diabetes and cardiovascular disease separately. Neither passage addresses whether people with diabetes have a high rate of cardiovascular events (searched: “diabetes cardiovascular events” and “cardiovascular”). (LLM, conf=0.77)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Could not verify
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Moderately increased albuminuria without hypertension indicates increased relative risk of CKD progression, but absolute risks of end-stage kidney disease are higher with concomitant hypertension (485-487).”
What the sources say
- Not checked — no full text of the sourcecites [485] Weir, 2010, Editorial perspective. Should microalbuminuria ever be considered as a renal endpoint in any clinical trial?, Am J Nephrol source
- Not checked — no full text of the sourcecites [486] Mok, 2021, Albuminuria and prognosis among individuals with atherosclerotic cardiovascular disease: the ARIC study, J Am Coll Cardiol source
- Could not verifycites [487] Mok, 2019, Albuminuria as a predictor of cardiovascular outcomes in patients with acute myocardial infarction, J Am Heart Assoc sourceExperimental — accuracy not yet measured
The Introduction and Conclusions examine albuminuria as a predictor of cardiovascular outcomes after myocardial infarction, not CKD progression or end-stage kidney disease. Searches for relative and absolute kidney-disease risks with and without hypertension found only a related reference title, not a passage stating the claimed comparison. (LLM, conf=0.75)
Strength:hedged· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
Every source the paper cites for this claim was checked and supports it.
In the paper
“The authors concluded that calibration bias was the main source of error for differences among methods and precision was adequate for most assays.”
What the sources say
- Supportedcites [498] Bachmann, 2014, State of the art for measurement of urine albumin: comparison of routine measurement procedures to isotope dilution tandem mass spectrometry, Clin Chem source
The Discussion (page not provided) identifies bias as the dominant source of disagreement among routine methods and calls for standardized calibration traceability. It also says imprecision was generally good, with combined CVs below 10% except for five procedures. (LLM, conf=0.92)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim. It may state two separate claims as one.
- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Screening using two tests with either being positive interpreted as a positive (leading to subsequent quantitative testing) increases the sensitivity to 97% but reduces the specificity to 83% (500,501).”
What the sources say
- Not checked — no full text of the sourcecites [500] McTaggart, 2014, Diagnostic accuracy of point-of-care tests for detecting albuminuria: a systematic review and meta-analysis, Ann Intern Med source
- Could not verifycites [501] Shin, 2021, Albuminuria testing in hypertension and diabetes: an individual-participant data meta-analysis in a global consortium, Hypertension sourceExperimental — accuracy not yet measured
The Results section on ACR testing rates reports how often patients were tested, and the Methods section describes repeat ACR measurements. Neither evaluates a two-test screening rule in which either positive result triggers quantitative testing, or reports 97% sensitivity and 83% specificity. Searches for those figures and the two-test rule found no supporting passage in our copy; page numbers were not available. (LLM, conf=0.76)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Moreover, the authors point out that it can minimize the testing time and inconvenience and significantly reduce national health costs (503).”
What the sources say
- Supportedcites [503] Kim, 2020, Can a semi-quantitative method replace the current quantitative method for the annual screening of microalbuminuria in patients with diabetes? Diagnostic accuracy and cost-saving analysis considering the potential health burden, PLoS One source
The Introduction (page unavailable) describes the quantitative test as time-consuming and requiring transport to a central laboratory, while presenting the semiquantitative test as a point-of-care alternative. The Discussion calls the semiquantitative method convenient, and Results Table 4 estimates a 23.8% cost saving for the modeled 10-year screening strategy in Korea. (LLM, conf=0.91)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim. It may state two separate claims as one.
- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“In the KDIGO and ADA algorithms for urine albumin testing (506), the diagnosis of moderately increased or severely increased albuminuria requires the demonstration of increased albumin excretion on two of three tests repeated at intervals over a period of 3 to 6 months and exclusion of conditions that invalidate the test.”
What the sources say
- Could not verifycites [506] American Diabetes Association Professional Practice Committee, 2021, 12. Retinopathy, neuropathy, and foot care: Standards of Medical Care in Diabetes—2022, Diabetes Care sourceExperimental — accuracy not yet measured
Split into 2 atoms — 0 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 2 unverifiable. Expand the claim to see per-atom verdicts.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
- Could not verify
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“The authors concluded that a negative semiquantitative POC test result does not rule out albuminuria, whereas quantitative POC testing meets required performance standards and can be used to rule out albuminuria.”
What the sources say
- Could not verifycites [501] Shin, 2021, Albuminuria testing in hypertension and diabetes: an individual-participant data meta-analysis in a global consortium, Hypertension sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) mentions routine urine dipstick testing, but does not evaluate negative semiquantitative results. The Discussion (page unavailable) concerns ACR screening rates, not point-of-care test accuracy. Searches for semiquantitative and quantitative POC testing found no passage addressing rule-out performance or required standards. (LLM, conf=0.76)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The most reliable method is the immunoturbidimetric laboratory assay, which should be considered the standard for comparison as it has >95% sensitivity and specificity to detect moderately increased albuminuria (505).”
What the sources say
- Partly supportedcites [505] Shaikh, 2008, Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin, Clin Chem sourceExperimental — accuracy not yet measured
The Materials and Methods (IMMUNOASSAY; page unavailable) identify immunoturbidimetry as the laboratory’s routine clinical urine-albumin assay. But the Results (METHOD COMPARISON; page unavailable) report that it underestimated albumin with the supplied calibrators, and the paper gives no >95% diagnostic sensitivity or specificity for detecting moderately increased albuminuria. It does not establish immunoturbidimetry as the most reliable method or the standard for comparison. (LLM, conf=0.88)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Sensitivity and specificity estimates for the quantitative test were 96% (95% CI, 78-99%) and 98% (95% CI, 93-99%), respectively.”
What the sources say
- Could not verifycites [501] Shin, 2021, Albuminuria testing in hypertension and diabetes: an individual-participant data meta-analysis in a global consortium, Hypertension sourceExperimental — accuracy not yet measured
The Methods (Outcomes and Statistical Analyses) and Results (ACR Testing Rate and Prevalence of ACR ≥30 mg/g) describe albumin-to-creatinine ratio testing rates and albuminuria prevalence, not the diagnostic accuracy of a quantitative point-of-care test. Searches for the quantitative test, sensitivity, specificity, and the stated confidence intervals found no passage supporting the 96% and 98% estimates. Page numbers were not available in our copy. (LLM, conf=0.76)
Load-bearingStrength:hedged· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“and that measures of insulin resistance (which include insulin measurements) predicted risk of diabetes or CAD only moderately, with no threshold effects (509).”
What the sources say
- Partly supportedcites [509] Rutter, 2008, Use of alternative thresholds defining insulin resistance to predict incident type 2 diabetes mellitus and cardiovascular disease, Circulation sourceExperimental — accuracy not yet measured
The Conclusions report modest predictive performance and no apparent threshold effects for surrogate measures of insulin resistance. However, the paper assesses diabetes and cardiovascular disease (CVD), not coronary artery disease (CAD) separately; the DM and CVD Assessment section defines CVD to include noncoronary events such as stroke and heart failure. (LLM, conf=0.86)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Stakeholders in the U.S., Japan, and elsewhere have worked on developing a reference standard and traceability schemes, but there is a need for further coordination to assure worldwide harmonization of C-peptide (516).”
What the sources say
- Supportedcites [516] Little, 2017, Implementing a reference measurement system for C-peptide: successes and lessons learned, Clin Chem source
The Conclusions say that lack of coordination can hinder global harmonization and that better communication and coordination are important. The Summary describes C-peptide standardization efforts in the US, Japan, and elsewhere, along with a proposed traceability scheme. (LLM, conf=0.94)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The pooled sensitivity and specificity at each cutoff point were the following: uACR >30 mg/g, 0.82 (95% CI, 0.76-0.87)and 0.88 (95% CI, 0.83-0.91);uACR 30 to 300 mg/g, 0.72 (95% CI, 0.68-0.77)and 0.82 (95% CI, 0.76-0.89);and uACR >300 mg/g, 0.84 (95% CI, 0.71-0.90)and 0.97 (95% CI, 0.95-0.99),respectively.”
What the sources say
- Partly supportedcites [502] Mejia, 2021, Diagnostic accuracy of urine dipstick testing for albumin-to-creatinine ratio and albuminuria: a systematic review and meta-analysis, Heliyon sourceExperimental — accuracy not yet measured
The Results of meta-analyses and Summary of findings report all six pooled sensitivity and specificity estimates at the stated ACR cutoffs. However, the citing sentence gives two confidence-interval bounds that differ from those sections: specificity at 30–300 mg/g ends at 0.89 rather than 0.86, and sensitivity at >300 mg/g begins at 0.71 rather than 0.74. Those bounds do appear in the paper’s Abstract, so the paper is internally inconsistent on them. (LLM, conf=0.84)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“HNF1B-MODY”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (shown under Future Considerations; page not provided) lists HNF1B as the gene for HNF1B-MODY. The Maturity-Onset Diabetes of the Young section also discusses HNF1B mutations or deletions in this context. (LLM, conf=0.93)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“ABCC8 | AD”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists ABCC8 under neonatal diabetes with inheritance marked “AD.” The table defines AD as autosomal dominant. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“HNF1B | AD”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists HNF1B with inheritance marked “AD,” meaning autosomal dominant. The Maturity-Onset Diabetes of the Young section also describes MODY inheritance as autosomal dominant. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“KCNJ11 | AD”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists KCNJ11 under neonatal diabetes with inheritance marked “AD,” and the table defines AD as autosomal dominant. The Neonatal Diabetes section also describes permanent neonatal diabetes caused by KCNJ11 mutations as autosomal dominant. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“atrophy of the pancreas”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists “atrophy of the pancreas” among the clinical features of HNF1B-MODY. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This clinical situation is quite rare and usually occurs in individuals with insulin-treated type 2 diabetes”
What the sources say
- Partly supportedcites [519] Hu, 2018, Exogenous insulin antibody syndrome (EIAS): a clinical syndrome associated with insulin antibodies induced by exogenous insulin in diabetic patients, Endocr Connect sourceExperimental — accuracy not yet measured
The Introduction describes sporadic reports of high-titre insulin antibodies, and the ‘Increased insulin resistance and risk of hyperglycaemia’ section associates high titres with insulin resistance. The Conclusion recommends investigating insulin-treated type 2 patients with unexplained glucose problems, but the paper does not establish that this situation usually occurs in type 2 rather than type 1 diabetes. (LLM, conf=0.84)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“hyperuricemia”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists hyperuricemia among the clinical features of HNF1B-MODY. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“INS | AD”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists INS under neonatal diabetes with inheritance marked “AD,” which the table defines as autosomal dominant. The Neonatal Diabetes section also says most diabetes-causing INS mutations are dominantly inherited. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“autoimmune diabetes”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The FOXP3 row of the table in Future Considerations explicitly lists autoimmune diabetes as a feature of IPEX syndrome. The Diagnosis section also associates IPEX with type 1 diabetes. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“EIF2B1 | AD”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists EIF2B1 with an inheritance designation of “AD.” The table defines AD as autosomal dominant. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“epiphyseal dysplasia”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The table in Future Considerations explicitly lists “Wolcott-Rallison syndrome: epiphyseal dysplasia” under EIF2AK3-associated permanent diabetes. This directly supports the attributed characterization. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“mechanisms include UPD6”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations; page not provided) lists 6q24 neonatal diabetes as transient and explicitly names UPD6, paternal duplication, and maternal methylation defect as mechanisms. Its footnote defines UPD6 as uniparental disomy of chromosome 6. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“immunodysregulation”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The Diagnosis section spells out IPEX as immune dysregulation, polyendocrinopathy, enteropathy, and X-linked syndrome. The FOXP3 entry in the Future Considerations table repeats those characteristics. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“GATA6 | AD”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists GATA6 under the Gene column and “AD” under Inheritance. The table defines AD as autosomal dominant. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“FOXP3 | X-linked”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The table of common causes of monogenic diabetes (Future Considerations, Table 2.6) lists FOXP3 with an inheritance pattern of “X-linked.” The Diagnosis section also identifies IPEX as an X-linked disorder caused by FOXP3 mutation. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“EIF2AK3 | AR”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 (Future Considerations) lists EIF2AK3 with inheritance marked “AR” and defines “AR” as autosomal recessive. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“autoimmune thyroid disease”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The table in Future Considerations lists autoimmune thyroid disease among the conditions associated with FOXP3-related IPEX syndrome. This directly supports the attributed characterization. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“exfoliative”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
The Future Considerations table lists exfoliative dermatitis among the features of IPEX syndrome. This directly supports the attributed claim. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“insulin requiring”
What the sources say
- Supportedcites [2] American Diabetes Association Professional Practice Committee, 2021, 2. Classification and diagnosis of diabetes: Standards of Care in Diabetes—2022, Diabetes Care source
Table 2.6 in Future Considerations lists FOXP3-associated IPEX syndrome and describes its diabetes as “insulin requiring.” (LLM, conf=0.94)
Strength:plain· not yet calibratedTests✗ Asserted: fails✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The authors may not put it forward as true. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
- Supported
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Issues of concern remain (a) overmodeling of the calibration data, (b) uncontrolled variations associated with skin, and (c) poor specificity for indirect methods.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“The resulting calibration models cannot measure glucose concentrations accurately during subsequent OGTTs, thereby severely limiting clinical utility.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“However, Heise and coworkers provide a complete analysis of these measurements and conclude that direct measurement of glucose is not possible at the measured wavelength bands and that the system, as described, lacks the ability to produce stable calibration functions required for practical clinical operation (240).”
What the sources say
- Not checked — no full text of the sourcecites [240] Vahlsing, 2018, Noninvasive monitoring of blood glucose using color-coded photoplethysmographic images of the illuminated fingertip within the visible and near-infrared range: opportunities and questions, J Diabetes Sci Technol source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim. It may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“For example, the HbA 1c concentration at the first prenatal visit identifies risk of adverse pregnancy outcomes and diabetes during pregnancy but is less effective for ascertainment of GDM (285,286).”
What the sources say
- Not checked — no full text of the sourcecites [285] Mañé, 2017, Role of first-trimester Hb1c as a predictor of adverse obstetric outcomes in a multiethnic cohort, J Clin Endocrinol Metab source
- Not checked — no full text of the sourcecites [286] Fong, 2014, Use of hemoglobin A1c as an early predictor of gestational diabetes mellitus, Am J Obstet Gynecol source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Although urine glucose is detectable in individuals with grossly increased blood glucose concentrations, it provides no information about blood glucose concentrations below the variable renal glucose threshold (approximately 10 mmol/L [180 mg/dL]).”
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Rests on an assumption: The renal glucose threshold is approximately 10 mmol/L (180 mg/dL).
In the paper
“Compared with testing urine ketones, children with type 1 diabetes (and caregivers) were more likely to measure blood ketones during periods of illness, and those randomized to blood ketone testing had almost half the number of emergency department visits or hospitalizations (302).”
What the sources say
- Not checked — no full text of the sourcecites [302] Laffel, 2006, Sick day management using blood 3-hydroxybutyrate (3-OHB) compared with urine ketone monitoring reduces hospital visits in young people with T1DM: a randomized clinical trial, Diabet Med source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Furthermore, the extent of renal concentration of the urine will affect urine glucose concentrations and only average glucose values between voidings are reflected, further minimizing the value of urine glucose determinations.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“The average yield is 30 to 40 mg DNA from 1 mL of whole blood.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Diabetes can be diagnosed by demonstrating increased concentrations of glucose in venous plasma or increased hemoglobin A 1c (HbA 1c ) in the blood.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes? Based: unclearIt may state two separate claims as one.
- Rests on an assumption: HbA1c reflects long-term blood glucose concentrations.
In the paper
“(c) symptoms of diabetes and a casual (i.e., regardless of the time of the preceding meal) plasma glucose $11.1 mmol/L (200 mg/dL)”
What the sources say
- Not checked — no full text of the sourcecites [18] The Expert Committee on the Diagnosis and Classification of Diabetes Mellitus, 1997, Report of the Expert Committee on the Diagnosis and Classification of Diabetes Mellitus, Diabetes Care source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
In the paper
“Global estimates are that approximately 50% of people with diabetes are undiagnosed (7).”
What the sources say
- Not matchedcites [7] International Diabetes Federation . IDF Diabetes Atlas. 10th ed.2021. Accessed 23 May 2022. Available from https://diabetesatlas.org/idfawp/resource-files/2021/07/IDF_Atlas_10th_Edition_2021.pdf
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:hedged· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
In the paper
“The revised criteria comprised (a) fasting plasma glucose (FPG) $7.0 mmol/L (126 mg/dL)”
What the sources say
- Not checked — no full text of the sourcecites [18] The Expert Committee on the Diagnosis and Classification of Diabetes Mellitus, 1997, Report of the Expert Committee on the Diagnosis and Classification of Diabetes Mellitus, Diabetes Care source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“A short turnaround time for glucose analysis is not usually necessary for the diagnosis of diabetes.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
In the paper
“Therapy in participants with type 2 diabetes in the UKPDS (52) was adjusted according to FPG concentrations-BGM was not utilized.”
What the sources say
- Not checked — no full text of the sourcecites [52] UK Prospective Diabetes Study (UKPDS) Group, 1998, Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33), Lancet source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“A very few laboratories (<1%) use glucose dehydrogenase.”
What the sources say
- Not matchedcites [85] Sacks, 2023, Carbohydrates
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Using biological variation as the basis for deriving analytical performance characteristics (87), the following desirable specifications for glucose have been proposed (95,96): analytical imprecision #2.4%, bias #2.1%, and total error #6.1%.”
What the sources say
- Not checked — no full text of the sourcecites [87] Fraser, 1999, Analytical performance characteristics should be judged against objective quality specifications, Clin Chem source
- Not checked — no full text of the sourcecites [95] Aarsand, 2018, The EuBIVAS: within- and between-subject biological variation data for electrolytes, lipids, urea, uric acid, total protein, total bilirubin, direct bilirubin, and glucose, Clin Chem source
- Not checked — no full text of the sourcecites [96] González-Lao, 2019, Systematic review of the biological variation data for diabetes related analytes, Clin Chim Acta source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“However, this value is based on suggestions of clinicians and no outcome data have been published that validate this figure.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“No consensus has been achieved on the analytic goals for glucose analysis, although numerous criteria have been proposed.”
What the sources say
- Not checked — no full text of the sourcecites [87] Fraser, 1999, Analytical performance characteristics should be judged against objective quality specifications, Clin Chem source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Intensive glycemic control can decrease microvascular complications as shown by the DCCT for individuals with type 1 (50) diabetes and by the UKPDS for type 2 (52) diabetes.”
What the sources say
- Not checked — no full text of the sourcecites [50] Nathan, 1993, The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus, N Engl J Med source
- Not checked — no full text of the sourcecites [52] UK Prospective Diabetes Study (UKPDS) Group, 1998, Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33), Lancet source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Reference intervals in children are 3.3 to 5.6 mmol/L (60 to 100 mg/dL), similar to the adult range of 4.1 to 5.5 mmol/L (74 to 99 mg/dL) (66).”
What the sources say
- Not matchedcites [66] Rifai, 2017, Carbohydrates
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Thus, the biological variability within an individual is substantially greater than analytic variability; analytic imprecision makes a negligible contribution to variation in patient results.”
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“BGM and CGM can be useful for detecting asymptomatic hypoglycemia and allowing people to avoid severe hypoglycemic episodes, especially when insulin is used in treatment.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Analytical bias and/or imprecision at low concentrations can lead to frequent false alarms of neonatal hypoglycemia or missed cases of true hypoglycemia (134).”
What the sources say
- Not checked — no full text of the sourcecites [134] Inman, 2021, Contribution of glucose meter error to misclassification of neonatal glycemic status, JAMA Pediatr source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Frequent use of BGM (or CGM) is particularly important for tight glycemic control and avoidance of frequent hypoglycemia in type 1 diabetes.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
In the paper
“The risk of hypoglycemia is seen primarily in individuals treated with insulin or insulin secretagogues, and risk increases significantly when pharmacologic therapy is directed toward maintaining glucose concentrations close to those found in individuals without diabetes (52).”
What the sources say
- Not checked — no full text of the sourcecites [52] UK Prospective Diabetes Study (UKPDS) Group, 1998, Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33), Lancet source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Recurrent education at clinic visits and comparison of BGM with concurrent laboratory glucose analysis have been shown to improve the accuracy of BGM (116).”
What the sources say
- Not checked — no full text of the sourcecites [116] Kabadi, 1994, The effect of recurrent practice at home on the acceptability of capillary blood glucose readings. Accuracy of self blood glucose testing, Diabetes Care source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Furthermore, many individuals with diabetes, particularly those with type 1, lose the autonomic warning symptoms that normally precede neuroglycopenia (”
What the sources say
- Not checked — no full text of the sourcecites [108] Gerich, 1991, Hypoglycemia unawareness, Endocr Rev source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“High hematocrit will increase or decrease the measured glucose, or will have minimal effect, depending on the design of the measuring system (132,133).”
What the sources say
- Not checked — no full text of the sourcecites [132] Warner, 2011, Can one point-of-care glucose meter be used for all pediatric and adult hospital patients? Evaluation of three meters, including recently modified test strips, Diabetes Technol Ther source
- Not checked — no full text of the sourcecites [133] Ceriotti, 2015, Comparative performance assessment of point-of-care testing devices for measuring glucose and ketones at the patient bedside, J Diabetes Sci Technol source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“The incidence of major hypoglycemic episodes-requiring third-party help or medical interventionwas two-to threefold higher in the intensive group than in the conventional group in clinical trials of participants with type 1 and type 2 diabetes, with the absolute rate far higher in type 1 diabetes than in type 2 (52).”
What the sources say
- Not checked — no full text of the sourcecites [52] UK Prospective Diabetes Study (UKPDS) Group, 1998, Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33), Lancet source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Hypoglycemia is a major risk in treatment of diabetes, and BGM or CGM may help to detect and avoid this potentially life-threatening complication.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Hematocrit affects the glucose results of some meters, with falsely high glucose results at low hematocrits and falsely low results at high hematocrits (143,144).”
What the sources say
- Not checked — no full text of the sourcecites [143] Wada, 2015, Evaluation of two glucose meters and interference corrections for screening neonatal hypoglycemia, Pediatr Int source
- Not checked — no full text of the sourcecites [144] Demircik, 2015, Evaluation of hematocrit interference with MyStar extra and seven competitive devices, J Diabetes Sci Technol source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“In a large trial of rt-CGM in people with type 1 diabetes showing significant reductions in HbA 1c in adults (159), improved glucose control was not seen in children (ages 8 to 14 years) or adolescents and young adults (ages 15 to 24 years).”
What the sources say
- Not checked — no full text of the sourcecites [159] Tamborlane, 2008, Continuous glucose monitoring and intensive treatment of type 1 diabetes, N Engl J Med source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“One RCT showed less time in the hypoglycemic range, without significant change in HbA 1c (163).”
What the sources say
- Not checked — no full text of the sourcecites [163] Bolinder, 2016, Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial, Lancet source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Professional CGM, along with professional interpretation, patient education, and therapy adjustments, may help reduce hyper-and/or hypoglycemia, but rigorous data are lacking (105).”
What the sources say
- Not checked — no full text of the sourcecites [105] American Diabetes Association Professional Practice Committee, 2021, 7. Diabetes technology: Standards of Medical Care in Diabetes—2022, Diabetes Care source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“However, with increasing prevalence of undiagnosed type 2 diabetes in women of childbearing age, the definition changed to exclude diabetes found (by standard nonpregnancy criteria) at an early prenatal visit.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“A few years later a two-step approach was advocated, in which a screening 50-g glucose challenge test was introduced to rule out women who would not need a full OGTT; only women who failed the screening test went on to an OGTT (250).”
What the sources say
- Not checked — no full text of the sourcecites [250] Committee on Practice Bulletins—Obstetrics, 2018, ACOG Practice Bulletin No. 190: gestational diabetes mellitus, Obstet Gynecol source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“Using the IADPSG criteria substantially increases the incidence of GDM, mainly because only one increased glucose value is required to diagnose GDM rather than two.”
What the sources say
- Not checked — no full text of the sourcecites [258] Metzger, 2010, International association of diabetes and pregnancy study groups recommendations on the diagnosis and classification of hyperglycemia in pregnancy, Diabetes Care source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“The original O'Sullivan and Mahan diagnostic criteria were based on blood glucose values in a 3-h 100-g OGTT predictive of later risk of diabetes mellitus in the women (252).”
What the sources say
- Not matchedcites [252] O’Sullivan, 1964, Criteria for the oral glucose tolerance test in pregnancy, Diabetes
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
None of the sources cited for this claim have been checked yet.
In the paper
“In 2013 a National Institutes of Health (NIH) Consensus Development Conference Statement recommended that the two-step approach for detection and diagnosis of GDM, predominately used in the U.S., should continue to be used rather than the 1-step approach and criteria proposed by IADPSG (253,254).”
What the sources say
- Not checked yetcites [253] Vandorsten, 2013, NIH consensus development conference: diagnosing gestational diabetes mellitus, NIH Consens State Sci Statements
- Not checked — no full text of the sourcecites [254] Anonymous, 2013, NIH consensus development conference statement: diagnosing gestational diabetes mellitus, March 4-6, 2013, Obstet Gynecol source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“In 2014 the ADA acknowledged that consensus had not been reached concerning detection and diagnosis of GDM and endorsed the use of either the 1-step or the 2-step approach (260).”
What the sources say
- Not checked — no full text of the sourcecites [260] American Diabetes Association, 2014, Standards of medical care in diabetes—2014, Diabetes Care source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“The diagnostic thresholds for GDM, especially for FPG, are substantially lower than those for diabetes i.e., 92 mg/dL (5.1 mmol/L) or 95 mg/dL (5.3 mmol/L) by IADPSG or Carpenter-Coustan criteria, respectively (Table 7).”
What the sources say
- Not matchedcites Table 7
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Insulinindependent glucose uptake by the fetus and placenta leads to lower fasting glucose values, while diabetogenic placental hormones produce postprandial hyperglycemia and carbohydrate intolerance.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Notwithstanding these limitations, urine glucose monitoring is supported by the IDF in situations where blood glucose monitoring is not accessible or affordable, particularly in resource-poor settings (296).”
What the sources say
- Not checked — no full text of the sourcecites [296] IDF Clinical Guidelines Task Force, 2006, Global guideline for type 2 diabetes: recommendations for standard, comprehensive, and minimal care, Diabet Med source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
In the paper
“Commercially available strips use the glucose oxidase reaction (89).”
What the sources say
- Not checked — no full text of the sourcecites [89] Fraser, 1990, The necessity of achieving good laboratory performance, Diabet Med source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Based on analysis of OGTT results from the Danish Odense Cohort Study (289,290), McIntyre et al. (289) have questioned the universal use of the value $92 mg/dL (5.1 mmol/L) as the FPG threshold for a diagnosis of GDM by the IADPSG (258) and WHO (259) criteria for GDM.”
What the sources say
- Not checked — no full text of the sourcecites [289] McIntyre, 2018, Gestational diabetes mellitus: does one size fit all? A challenge to uniform worldwide diagnostic thresholds, Diabetes Care source
- Not checked — no full text of the sourcecites [290] Kyhl, 2015, The Odense Child Cohort: aims, design, and cohort profile, Paediatr Perinat Epidemiol source
- Not checked — no full text of the sourcecites [258] Metzger, 2010, International association of diabetes and pregnancy study groups recommendations on the diagnosis and classification of hyperglycemia in pregnancy, Diabetes Care source
- Not checked — no full text of the sourcecites [259] Colagiuri, 2014, Strategies for implementing the WHO diagnostic criteria and classification of hyperglycaemia first detected in pregnancy, Diabetes Res Clin Pract source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“In contrast to POCT, laboratories that measure HbA 1c need to have a CLIA certificate, be inspected, and meet the CLIA quality standards (326).”
What the sources say
- Not matchedcites [326] U.S. Centers for Medicare & Medicaid Services . CLIA brochures. Accessed 26 August 2022. Available from https://www.cms.gov/Regulations-and-Guidance/Legislation/CLIA/CLIA_Brochures
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Not matched
In the paper
“These standards include specified personnel requirements (including documented annual competency assessments) and participation three times per year in an approved proficiency testing program.”
What the sources say
- Not matchedcites [326] U.S. Centers for Medicare & Medicaid Services . CLIA brochures. Accessed 26 August 2022. Available from https://www.cms.gov/Regulations-and-Guidance/Legislation/CLIA/CLIA_Brochures
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Not matched
In the paper
“Intraindividual CVs in healthy people are very small (<2%), and many current assay methods can achieve intralaboratory CVs <1.5% and interlaboratory CVs <2.0% among different laboratories using the same method (366).”
What the sources say
- Not matchedcites [366] Sacks, 2020
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Not matched
In the paper
“Analysis is performed by cleaving hemoglobin with endoproteinase Glu-C and separating the resulting glycated and nonglycated N-terminal b-chain hexapeptides by HPLC (363).”
What the sources say
- Not checked — no full text of the sourcecites [363] Hoelzel, 2004, IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study, Clin Chem source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These haplotypes are common in the general population and confer increased risk but are not causative for type 1 diabetes.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“As noted above, the NGSP has largely succeeded in standardizing the GHb assay across methods and laboratories.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Furthermore, the IFCC reference method, which provides reference materials for manufacturers, is being implemented worldwide.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“However, HLA typing is useful for clinical research studies, either in subjects followed from birth or children identified by autoantibody screening of relatives of individuals with type 1 diabetes.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“This material is formed rapidly with hyperglycemia and could interfere with some HbA 1c assay methods if not completely removed or separated.”
What the sources say
- Not checked — no full text of the sourcecites [368] Goldstein, 1980, Effects of acute changes in blood glucose on HbA1c, Diabetes source
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Therefore, HLA molecules are genetic etiological factors in the initiation phase of autoimmune diabetes but not during pathogenesis.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Four major genetic forms of MODY have been identified (Table 8) and individuals at risk within MODY pedigrees can be identified through genetic means.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“People at the highest genetic risk of type 1 diabetes are those in whom all four DQ combinations meet this criterion.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“HLA-DQ genes appear to be central to the HLA-associated risk of type 1 diabetes, albeit DR genes may be independently involved.”
Strength:hedged· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
What the paper did — it cites no source for this, so there is none to check. The quote shows it is in the paper.
In the paper
“Blood samples should be drawn into test tubes containing EDTA and the DNA preparations should be harvested within 3 days; longer periods both lower the yield and degrade the quality of the DNA obtained.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“There are over 60 distinct genetic disorders associated with glucose intolerance or frank diabetes.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
What the paper did — it cites no source for this, so there is none to check. The quote shows it is in the paper.
In the paper
“DNA samples are best kept at À80 C in Tris-EDTA solution, where the integrity of the sample lasts virtually indefinitely.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“The islet autoantibodies are directed against insulin (IAA), GAD65 (GADA), insulinoma-associated antigen 2 (IA-2A), or zinc transporter 8 (ZnT8A) and predict type 1 diabetes.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Insulin treatment precludes the analysis of IAA as it takes only about 11 days before insulin antibodies are induced.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
In the paper
“The risk of type 1 diabetes in HLA-identical siblings of a proband with type 1 diabetes is 1 in 4, while siblings who have HLA-haplotype identity have a 1 in 12 risk and those with no shared haplotype a 1 in 100 risk (403).”
What the sources say
- Not checked — no full text of the sourcecites [403] Pociot, 2016, Genetic risk factors for type 1 diabetes, Lancet source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“After years of type 1 diabetes, the autoantibodies tend to fall below detection limits, but GADA usually remains increased.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“The ensuing autoimmunity may be present for months or years prior to the appearance of two or more islet autoantibodies without either dysglycemia or symptoms (Stage 1) and the subsequent development of dysglycemia (Stage 2), followed by the onset of hyperglycemia and symptoms of diabetes (Stage 3) (see Table 9).”
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“As many as 1 in 4 females with type 1 diabetes have autoimmune thyroid disease while 1 in 280 individuals develop adrenal autoantibodies and adrenal insufficiency (419).”
What the sources say
- Not checked — no full text of the sourcecites [419] Nederstigt, 2019, Associated auto-immune disease in type 1 diabetes patients: a systematic review and meta-analysis, Eur J Endocrinol source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“ICA is determined by indirect immunofluorescence on frozen sections of human pancreas (436).”
What the sources say
- Not checked — no full text of the sourcecites [436] Gleichmann, 1987, Progress toward standardization of cytoplasmic islet cell-antibody assay, Diabetes source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“Children with certain HLA-DQB1 alleles such as B1*06:02, B1*06:03, or B1*03:01 are mostly protected from type 1 diabetes but not from developing islet autoantibodies (424) or from type 1 diabetes later in life.”
What the sources say
- Not checked — no full text of the sourcecites [424] Schott, 1994, GAD65 autoantibodies increase the predictability but not the sensitivity of islet cell and insulin autoantibodies for developing insulin dependent diabetes mellitus, J Autoimmun source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“The risk of developing type 1 diabetes in relatives of someone with the disease is approximately 5%, which is 15-fold higher than the risk in the general population (1 in 250 to 300 lifetime risk).”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Since immunoassays for IAA, GADA, IA-2A/IA-2bA, and ZnT8A are available, a panel of these autoantibodies can be used in screening studies (447).”
What the sources say
- Not checked — no full text of the sourcecites [447] Skyler, 2005, Effects of oral insulin in relatives of patients with type 1 diabetes: the Diabetes Prevention Trial—Type 1, Diabetes Care source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Positive results depend upon the study or context in which they are used, but many laboratories use 10 JDF units determined on two separate occasions, or a single result $20 JDF units, as significant titers which may convey an increased risk of type 1 diabetes.”
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“Approximately 5% to 10% of White adults who present with a type 2 diabetes phenotype have islet autoantibodies (425), particularly GADA, which predict insulin dependency.”
What the sources say
- Not checked — no full text of the sourcecites [425] Turner, 1997, UKPDS 25: autoantibodies to islet-cell cytoplasm and glutamic acid decarboxylase for prediction of insulin requirement in type 2 diabetes, Lancet source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“IA-2A may be present in about 40% to 80% of those newly diagnosed with type 1 diabetes, but the frequency is highest in the young and decreases with increasing age at onset.”
Strength:hedged· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“ICA is found in about 75% to 85% of people with newonset type 1 diabetes.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“GADA may be present in 60% to 80% of people newly diagnosed with type 1 diabetes, but the frequency varies with gender and age.”
Strength:hedged· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Although individuals who are GADA positive progress to absolute insulinopenia faster than do those who are autoanti-body negative, some autoantibody-negative adults with type 2 diabetes also progress (albeit more slowly) to insulin dependence with time.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These strategies will reduce both false-positive and -negative results.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“IAAs are positive in more than 70% to 80% of children who develop type 1 diabetes before age 5 years but in fewer than 40% of individuals developing diabetes after age 12.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“The Kidney Disease Improving Global Outcomes (KDIGO) group, representing international guidelines for kidney disease, reclassified albuminuria in 2020 (450), and these definitions have been adopted by the ADA.”
What the sources say
- Not checked — no full text of the sourcecites [450] Kidney Disease: Improving Global Outcomes (KDIGO) Diabetes Work Group, 2020, KDIGO 2020 Clinical practice guideline for diabetes management in chronic kidney disease, Kidney Int source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Islet autoantibody positivity rates are distinctly lower in the general population than in relatives of individuals with type 1 diabetes, so that trials in the latter group are more economical.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Rests on an assumption: Excessive albumin excretion in the urine is directly related to future loss of kidney function and increased cardiovascular risk.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These agents slow the rate of urine albumin excretion or prevent its development by reducing inflammation and decreasing intraglomerular pressure, reflected in a small reduction in eGFR.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Decreasing albuminuria by at least 30% lowers cardiovascular risk and events and slows CKD progression.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Whether centrifuged, filtered, or not treated, albumin concentration decreased by 0.27% per day at À20 C but showed no decrease over 160 days at À80 C (496).”
What the sources say
- Not checked — no full text of the sourcecites [496] MacNeil, 1991, Considerations when measuring urinary albumin: precision, substances that may interfere, and conditions for sample storage, Clin Chem source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“In healthy volunteers, the lowest CVi was observed for the albumin concentration in the first morning void (36%) and for the albuminto-creatinine ratio in that sample (31%) (491).”
What the sources say
- Not checked — no full text of the sourcecites [491] Howey, 1989, Biologic variation of urinary albumin: consequences for analysis, specimen collection, interpretation of results, and screening programs, Am J Kidney Dis source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Uncommonly, an individual can have as much as 40% to 50% variability in albumin excretion.”
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✗ Based: failsProbably not a substantial claim. The paper may give no reason why it holds.
In the paper
“Approximately 20% develop end-stage kidney disease and almost all will have severely increased albuminuria despite achievement of blood pressure goals (484).”
What the sources say
- Not checked — no full text of the sourcecites [484] Duka, 2008, Influence of microalbuminuria in achieving blood pressure goals, Curr Opin Nephrol Hypertens source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Urine albumin excretion rate reportedly has no marked diurnal variation in diabetes but does in essential hypertension (497).”
What the sources say
- Not checked — no full text of the sourcecites [497] Hishiki, 1998, Circadian variation of urinary microalbumin excretion and ambulatory blood pressure in patients with essential hypertension, J Hypertens source
Strength:hedged· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“The within-individual variation (CVi) of albumin excretion is large in people without diabetes and is moderately increased in people with diabetes (489).”
What the sources say
- Not checked — no full text of the sourcecites [489] Miller, 2009, Current issues in measurement and reporting of urinary albumin excretion, Clin Chem source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“The ratio correlates well with both timed excretion and albumin concentration in a first morning void of urine (489,491).”
What the sources say
- Not checked — no full text of the sourcecites [489] Miller, 2009, Current issues in measurement and reporting of urinary albumin excretion, Clin Chem source
- Not checked — no full text of the sourcecites [491] Howey, 1989, Biologic variation of urinary albumin: consequences for analysis, specimen collection, interpretation of results, and screening programs, Am J Kidney Dis source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Additionally, a >30% sustained reduction in albuminuria is accepted as a surrogate marker of slowed progression of kidney disease at the group level, e.g., in a clinical trial.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Taken together, these data support semiquantitative uACR dipstick testing as a useful approach when quantitative analysis is not possible.”
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Advantages of semiquantitative testing include relatively high specificity and use as point-of-care testing which, if appropriately implemented, can improve access (particularly in resourcelimited settings) and eliminate the need for shipping samples and delays in getting a test result.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“At least some of the semiquantitative POC methods have the wrong characteristics for screening because they exhibit low sensitivity and positive results must be confirmed by a laboratory method.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Clinical operators have a lower sensitivity but better specificity than laboratory technologists (500)”
What the sources say
- Not checked — no full text of the sourcecites [500] McTaggart, 2014, Diagnostic accuracy of point-of-care tests for detecting albuminuria: a systematic review and meta-analysis, Ann Intern Med source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“There are several therapeutic approaches for treating these individuals, and a quantitative estimate of the concentration of circulating insulin antibodies does not appear to be of significant benefit.”
Load-bearingStrength:hedged· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
The paper relies on this without support.
HbA1c reflects long-term blood glucose concentrations.
“recommended that diabetes could also be diagnosed by measurement of hemoglobin A 1c (HbA 1c ), which reflects long-term blood glucose concentrations”
The paper relies on this without support.
The correlation between interstitial and blood glucose concentrations is usually high.
“CGM devices have not been approved for use in hospitalized patients, in part due to concerns about accuracy, concomitant medication use, or theoretical alterations in the usually high correlation between interstitial and blood glucose concentrations caused by serious illness.”
The paper relies on this without support.
The diagnosis of gestational diabetes mellitus is totally dependent on accurate measurement of glucose.
“The diagnosis of GDM is totally dependent on accurate measurement of glucose.”
The paper relies on this without support.
The renal glucose threshold is approximately 10 mmol/L (180 mg/dL).
“it provides no information about blood glucose concentrations below the variable renal glucose threshold (approximately 10 mmol/L [180 mg/dL])”
The paper relies on this without support.
Urine test reagents deteriorate with exposure to air, giving false-negative readings.
“Urine test reagents deteriorate with exposure to air, giving false-negative readings; testing material should be stored in tightly sealed containers and discarded after the expiration date on the manufacturer's label.”
The paper relies on this without support.
False-negative readings occur with highly acidic urine specimens, such as after large intakes of ascorbic acid.
“False-negative readings have also been reported with highly acidic urine specimens, such as after large intakes of ascorbic acid.”
The paper relies on this without support.
Loss of ketones from urine attributable to microbial action can cause false-negative readings.
“Loss of ketones from urine attributable to microbial action can also cause false-negative readings.”
The paper relies on this without support.
Acetone is a highly volatile substance.
“Since acetone is a highly volatile substance, specimens should be kept in a closed container.”
The paper relies on this without support.
The nitroprusside method measures only acetoacetate unless the reagent contains glycine, in which case acetone is also measured.
“The nitroprusside method measures only AcAc unless the reagent contains glycine, in which case acetone is also measured.”
The paper relies on this without support.
The nitroprusside-containing reagent is much more sensitive to acetoacetate than acetone with respect to color generation.
“The nitroprussidecontaining reagent is much more sensitive to AcAc than acetone with respect to color generation.”
The paper relies on this without support.
Resolution of acidosis or reduction in blood beta-hydroxybutyrate is traditionally the marker for successful treatment of diabetic ketoacidosis, rather than serial measurement of ketones by the nitroprusside reaction.
“Resolution of acidosis or reduction in blood bOHB is traditionally the marker for successful treatment of DKA, rather than serial measurement of ketones by the nitroprusside reaction.”
The paper relies on this without support.
Beta-hydroxybutyrate concentrations in healthy individuals fasted overnight are generally less than 0.5 mmol/L.
“bOHB reference intervals differ among assay methods, but concentrations in healthy individuals fasted overnight are generally <0.5 mmol/L.”
The paper relies on this without support.
Glycated hemoglobin usually indicates the average glucose concentration over the preceding 60 to 90 days.
“Hemoglobin in the RBC has an average circulating life span of approximately 120 days, and glycated hemoglobin therefore usually indicates the average glucose concentration over the preceding 60 to 90 days.”
The paper relies on this without support.
The clinical utility of glycated proteins other than hemoglobin has not been clearly established.
“However, the clinical utility of glycated proteins other than hemoglobin has not been clearly established.”
The paper relies on this without support.
HbA1c results are not significantly affected by acute fluctuations in blood glucose concentrations, such as those that occur with illness or after meals.
“HbA 1c results are not significantly affected by acute fluctuations in blood glucose concentrations, such as those that occur with illness or after meals.”
The paper relies on this without support.
Boronate affinity chromatographic assay methods are generally considered to be less affected by hemoglobin variants than other methods.
“Boronate affinity chromatographic assay methods are generally considered to be less affected by hemoglobin variants than other methods.”
The paper relies on this without support.
HbA1c cannot be measured in individuals with homozygous hemoglobin variants or two variant hemoglobins, like HbSC; they have no HbA and therefore do not have HbA1c.
“It is important to emphasize that HbA 1c cannot be measured in individuals with homozygous hemoglobin variants (e.g., HbSS, HbCC, HbEE) or 2 variant hemoglobins, like HbSC; they have no HbA and therefore do not have HbA 1c .”
The paper relies on this without support.
For most methods, whole blood samples stored at -70 C or colder are stable long term (at least 1 year), but specimens are not as stable at -20 C.
“For most methods, whole blood samples stored at À70 C or colder are stable long term (at least 1 year), but specimens are not as stable at À20 C.”
The paper relies on this without support.
There are more than 300 HbA1c assay methods in current clinical use.
“There are >300 HbA 1c assay methods in current clinical use.”
The paper relies on this without support.
The two IFCC methods use the same primary reference materials and the results are essentially identical.
“The two methods use the same primary reference materials and the results are essentially identical.”
The paper relies on this without support.
The preparation and measurement of samples using the IFCC method is laborious, expensive, and time-consuming and was never envisioned as a practical means of assaying clinical samples.
“Of note, the preparation and measurement of samples using this method is laborious, expensive, and time-consuming and was never envisioned as a practical means of assaying clinical samples.”
The paper relies on this without support.
Currently available automated assays either remove the labile pre-HbA1c during the assay process or do not measure the labile product.
“Currently available automated assays either remove the labile pre-HbA 1c during the assay process or do not measure the labile product.”
The paper relies on this without support.
HbA1c values in people with diabetes are a continuum, ranging from within the nondiabetic reference interval in a small percentage of people to markedly increased values in some individuals.
“HbA 1c values in people with diabetes are a continuum; they range from within the nondiabetic reference interval in a small percentage of people whose mean plasma glucose concentrations are close to those of individuals without diabetes, to markedly increased values, e.g., two-to threefold higher levels than the nondiabetic mean of approximately 5%, in some individuals, reflecting extreme hypergly”
The paper relies on this without support.
Type 1 diabetes results from a selective autoimmune destruction of the pancreatic b-cell functional mass, eventually leading to an absolute lack of insulin and consequent hyperglycemia.
“Type 1 diabetes results from a selective autoimmune destruction of the pancreatic b-cell functional mass, eventually leading to an absolute lack of insulin and consequent hyperglycemia.”
The paper relies on this without support.
Type 1 diabetes is genetically linked to HLA of the major histocompatibility complex (MHC) on chromosome 6.
“Type 1 diabetes is genetically linked to HLA of the major histocompatibility complex (MHC) on chromosome 6.”
The paper relies on this without support.
Type 1 or autoimmune diabetes is strongly associated with HLA DR and DQ genes.
“Type 1 or autoimmune diabetes is strongly associated with HLA DR and DQ genes.”
The paper relies on this without support.
Mutation detection for MODY is technically feasible.
“Mutation detection for MODY is technically feasible.”
The paper relies on this without support.
The pathogenesis of type 1 diabetes is strongly associated with several immune abnormalities most prominently islet autoantibodies but also cooccurrence of other organ-specific autoimmune diseases such as autoimmune thyroid disease and celiac disease.
“The pathogenesis of type 1 diabetes is strongly associated with several immune abnormalities most prominently islet autoantibodies but also cooccurrence of other organ-specific autoimmune diseases such as autoimmune thyroid disease and celiac disease.”
The paper relies on this without support.
The clinical onset of type 1 diabetes is related to the loss of the functional b-cell mass.
“The clinical onset of type 1 diabetes is related to the loss of the functional b-cell mass.”
The paper relies on this without support.
Insulin treatment precludes the analysis of IAA as it takes only about 11 days before insulin antibodies are induced.
“Insulin treatment precludes the analysis of IAA as it takes only about 11 days before insulin antibodies are induced.”
The paper relies on this without support.
Islet autoantibodies are found in the general population.
“Islet autoantibodies are found in the general population.”
The paper relies on this without support.
Excessive albumin excretion in the urine is directly related to future loss of kidney function and increased cardiovascular risk.
“it is well known that excessive albumin excretion in the urine is directly related to future loss of kidney function and increased cardiovascular risk”
The paper relies on this without support.
The onset of type 2 diabetes is difficult to date precisely.
“the difficulty in precisely dating the onset of type 2 diabetes”
The paper relies on this without support.
Race is a social, not biologic, construct.
“race is a social, not biologic, construct”
The paper relies on this without support.
Clear inequities occur with use of race-based equations for eGFR.
“clear inequities occur with use of race-based equations for eGFR”
The paper relies on this without support.
Cystatin C assays are not widely available in the U.S.
“cystatin C assays are not widely available in the U.S.”
The paper relies on this without support.
Insulin resistance plays a critical role in the pathogenesis of type 2 diabetes.
“Due to the critical role of insulin resistance in the pathogenesis of type 2 diabetes”
The paper relies on this without support.
Accurate measurement of insulin resistance requires complex methods generally confined to research laboratories.
“accurate measurement of insulin resistance requires the use of complex methods, such as the hyperinsulinemiceuglycemic clamp technique, which are generally confined to research laboratories”
The paper relies on this without support.
Clinical operators do not wait the full time between dipping and scanning.
“perhaps because they do not wait the full time (usually 60 s) between dipping and scanning”
The paper relies on this without support.
Effective screening tests have low false-negative rates.
“Effective screening tests (e.g., for phenylketonuria) have low false-negative rates.”
The paper relies on this without support.
The normal rate of GFR loss is about 0.8 mL/min/year in diabetes.
“the normal rate of GFR loss is about 0.8 mL/min/year in diabetes”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Diabetes mellitus is a group of metabolic disorders of carbohydrate metabolism in which glucose is both underutilized as an energy source and overproduced due to inappropriate gluconeogenesis and glycogenolysis, resulting in hyperglycemia (1).”
From 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2024 (2024) · cites this paper as [1]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These devices measure interstitial fluid glucose that has diffused from the capillaries and into the subcutaneous tissue and may indicate a falsely low BG due to device compression, device calibration errors, and skin/soft tissue infections [4,6,7].”
From Non-Diabetic Hypoglycemia: Evaluation and Management in Adults (2025) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A1C may not be a suitable diagnostic test in people with anemia, people treated with erythropoietin, or people undergoing hemodialysis or HIV treatment (1,19,20).”
From 2. Diagnosis and classification of diabetes: standards of care in diabetes-2025 (2025) · cites this paper as [1]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, glycated albumin and fructosamine, which reflect average glycemia over a shorter time (15-30 days), are helpful in clinical management (65,66).”
From 11. Chronic Kidney Disease and Risk Management: Standards of Care in Diabetes—2026 (2026) · cites this paper as [66]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The balance between analytic requirements (e.g., accuracy, precision, and interference) and clinical requirements (e.g., rapidity, simplicity, and POC) has not been uniformly resolved (39)(40)(41)(42), and most hospitals have arrived at their own policies to balance these parameters.”
From 16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026 (2026) · cites this paper as [39]
Experimental — accuracy not yet measured
The cited source says what the claim attributes to it.
In the citing paper
“A1C cannot be measured in individuals with sickle cell disease (HbSS) or other homozygous hemoglobin variants (e.g., HbEE), since these individuals lack HbA (8).”
From 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026. (2026) · cites this paper as [8]
The cited source says what the claim attributes to it.
In the citing paper
“In people with diabetes who have conditions where the interpretation of A1C may be problematic or when A1C cannot be measured (e.g., homozygous hemoglobin variants), fructosamine or glycated albumin may be useful alternatives to monitor glycemic status (8).”
From 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026. (2026) · cites this paper as [8]
The cited source says what the claim attributes to it.
In the citing paper
“Glucose concentrations will be falsely low if samples are not processed promptly or stored properly prior to analysis (1).”
From 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2024 (2024) · cites this paper as [1]
The cited source says what the claim attributes to it.
In the citing paper
“These standards require that 95% of readings from a particular home glucometer fall within 15% of laboratory results.”
From Non-Diabetic Hypoglycemia: Evaluation and Management in Adults (2025) · cites this paper as [4]
The cited source says what the claim attributes to it.
In the citing paper
“This is because professional glucometers are held to a higher standard of accuracy [4].”
From Non-Diabetic Hypoglycemia: Evaluation and Management in Adults (2025) · cites this paper as [4]
The cited source says what the claim attributes to it.
In the citing paper
“The FDA has established standards for capillary (finger-stick) POC glucose monitoring in the hospital (39).”
From 16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026 (2026) · cites this paper as [39]
In the citing paper
“Because the reaction is sensitive to temperature, all monitors have an acceptable temperature range (37).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [37]
In the citing paper
“There are several physiologic and pharmacologic factors that interfere with glucose readings measured with either personal blood glucose meters or professional blood glucose meters used in various inpatient settings (neonatal intensive care unit, hospital wards, and intensive care unit) (37).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [37]
In the citing paper
“Glucose oxidase monitors are sensitive to the oxygen available and should only be used with capillary blood in people with normal oxygen saturation.Higher oxygen tensions (i.e., arterial blood or oxygen therapy) may result in false low-glucose readings, and low oxygen tensions (i.e., high altitude, hypoxia, or venous blood readings) may lead to falsely elevated glucose readings.”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [37]
In the citing paper
“Glucose dehydrogenase-based monitors are generally not sensitive to oxygen.”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [37]
In the citing paper
“Currently available glucose monitors use an enzymatic reaction linked to an electrochemical reaction, either glucose oxidase or glucose dehydrogenase (37).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [37]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
The stated 5.6 mmol/L interval uses the wrong percentage
MinorA range of 4.9 to 6.3 mmol/L is approximately 5.6 mmol/L ±12.5%, not ±6.4%. Applying 6.4% gives about 5.2 to 6.0 mmol/L.
“95% CI of 5.6 ± 6.4% (100 ± 6.4%)”
“namely, 4.9 to 6.3 mmol/L (87 to 113 mg/dL).”
The stated 7.0 mmol/L interval uses the wrong percentage
MinorA range of 6.1 to 7.9 mmol/L is approximately 7.0 mmol/L ±12.9%, not ±6.4%. Applying the stated 6.4% gives about 6.6 to 7.4 mmol/L.
“7.0 mmol/L ± 6.4% (126 mg/dL ± 6.4%)”
“namely, 6.1 to 7.9 mmol/L (110 to 142 mg/dL).”
The same IFCC value is assigned to two different HbA1c percentages
MinorThe reference-interval discussion equates 31 mmol/mol with both 5% and 5.6% HbA1c. Those percentages cannot both represent the same IFCC value.
“Many organizations and laboratories have lowered the upper limit of the reference interval to 5.6% (31 mmol/mol).”
“from a mean of 5% (31 mmol/mol) i.e., 4.5% to 5.5% (26 to 37 mmol/mol).”
Citations
Cites
Toprak, Ö., Kurt, H., Sarı, Y., Şarkış, C., Us, H., & Kırık, A. (2017) · Kidney & Blood Pressure Research · doi:10.1159/000468530 · Cited by 29,772
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
(1998) · The Lancet · doi:10.1016/s0140-6736(98)07019-6 · Cited by 20,023 · cited 12×
“The ADA has recommended specific treatment goals for HbA1c on the basis of results from prospective randomized clinical trials, most notably the DCCT for type 1 diabetes (44,197) and the UKPDS for type 2 diabetes (46).”
InfluentialReduction in the incidence of type 2 diabetes with lifestyle intervention or metformin
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa012512 · Cited by 19,011 · cited 1×
“Despite these recommendations and the demonstration that interventions can delay and sometimes prevent the onset of type 2 diabetes in individuals with impaired glucose tolerance (26,27), there is as yet no published evidence that treatment based on screening has an effect on long-term complications.”
International Diabetes Federation 2017
Carracher, A. M., Marathe, P. H., & Close, K. L. (2018) · Journal of Diabetes · doi:10.1111/1753-0407.12644 · Cited by 13,379
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271 · cited 2×
“An eGFR of ,60 mL/min, regardless of the presence of low levels of albuminuria, is an independent cardiovascular risk factor (325,327).”
Self-citationRole of Insulin Resistance in Human Disease
Reaven, G. M. (1988) · Diabetes · doi:10.2337/diab.37.12.1595 · Cited by 12,154 · cited 1×
“Type 2 diabetes is a heterogeneous polygenic disease with both resistance to the action of insulin and defective insulin secretion (3,4).”
Chronic kidney disease and the risks of death, cardiovascular events, and hospitalization
Go, A. S., Chertow, G. M., Fan, D., McCulloch, C. E., & Hsu, C.-Y. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041031 · Cited by 11,369
Tuomilehto, J., Lindström, J., Eriksson, J. G., Valle, T. T., Hämäläinen, H., Ilanne-Parikka, P., Keinänen-Kiukaanniemi, S., Laakso, M., Louheranta, A., Rastas, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105033441801 · Cited by 10,873 · cited 1×
“Despite these recommendations and the demonstration that interventions can delay and sometimes prevent the onset of type 2 diabetes in individuals with impaired glucose tolerance (26,27), there is as yet no published evidence that treatment based on screening has an effect on long-term complications.”
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Flagged first, then by citations
5 of the 535 references couldn’t be matched to a known paper.
Research works printed but not linked: 7
- Ladenson, 1980, Nonanalytical sources of variation in clinical chemistry results, 149
- Rifai, 2017, Carbohydrates
- Sacks, 2023, Carbohydrates, 353.e1
- Sacks, 2023, Diabetes mellitus, 502
- Little, 1998, A simple blood collection device for analysis of glycohemoglobin (GHB), Clin Chem, 44, A139
- Goldstein, 1997, Bringing order to chaos: the National Glycohemoglobin Standardization Program, Contemp Intern Med, 9, 27
- Sacks, 2020, Participant Summary for Hemoglobin A1c Survey 2020 Set GH5-C
Cited by
Sorted by citations
Items 101–200 of 334
Fabre-Estremera, B., Martínez-Chávez, E., Ocaña, M. M., Carcavilla, A., Sánchez, M. D. L. Á. M., Tejado, I. P., Casado, I. G., Losantos-García, I., Fernández–Calle, P., Soto, A. B., et al. (2024) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2024-0017 · Cited by 3
Li, X., Liu, X., Jiao, X., et al. (2024) · BMC Cardiovascular Disorders · doi:10.1186/s12872-024-04331-x · Cited by 3
Wang, M., Liao, J., Wang, H., Deng, L., Zhang, T., Guo, H., Qian, X., & Ma, R. (2025) · Nutrients · doi:10.3390/nu17010165 · Cited by 3
“(2) Diabetes mellitus is characterized as a condition affecting individuals who have received a definitive diagnosis of diabetes mellitus and are undergoing pharmacological treatment to regulate their blood glucose levels or have a fasting blood glucose (FBG) ≥ 7.0 mmol/L [19].”
InfluentialElectrocardiographic Changes in Patients with Type 2 Diabetes Mellitus—A Meta-Analysis
Alexescu, T., Nechita, A., Alexander, P. C., Perné, M.-G., Milaciu, M. V., Ciulei, G., Para, I., Negrean, V., Chiș, A. F., Todea, D. A., et al. (2025) · Journal of Mind and Medical Sciences · doi:10.3390/jmms12010014 · Cited by 3
Lomeli, L. D., Lundholm, M. D., Xiao, H., Zhou, K., & Pantalone, K. M. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.05.748 · Cited by 6
Liu, Z., Ma, Z., Jin, L., Nizhamuding, X., Zeng, J., Zhang, T., Zhang, J., Zhang, J., Zhao, H., Zhou, W., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.117859 · Cited by 5
Ng, H.-P., Chong, S. Y., Li, Y. H., Goh, T. H., Pang, K. Y., Pereira, M. J., & Huang, C.-M. (2024) · JMIR Research Protocols · doi:10.2196/56024 · Cited by 3
“Objective laboratory analysis of biochemical parameters such as fasting plasma glucose (FPG), HbA 1c , and oral glucose tolerance tests play a crucial role in the diagnosis of diabetes in Western medicine [21].”
MethodUse of labile HbA 1c as a screening tool to minimize clinical misinterpration of HbA 1c
Muynck, E. D., Lapauw, B., Delanghe, J., & Lambrecht, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-1200 · Cited by 3
Insulin delivery devices in diabetes management: Applications and advancements
Yang, R., Yang, Z., Chi, J., & Ya, Z. (2025) · Intelligent Pharmacy · doi:10.1016/j.ipha.2025.02.002 · Cited by 3
Immunomodulatory effect of allium sativum in type 2 diabetes mellitus
Delgado, E. M. M., Aldave, J. E. Q., Durand‐Vásquez, M. D. C., Aldave-Pita, L. N., Fuentes‐Mendoza, J. M., Urteaga, L. A. C., Paz‐Ibarra, J., & Concepción‐Zavaleta, M. J. (2025) · World Journal of Experimental Medicine · doi:10.5493/wjem.v15.i2.103481 · Cited by 5
Simental‐Mendía, L. E., Simental-Mendía, M. A., Barragán‐Zuñiga, L. J., & Arce‐Quiñones, M. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16506 · Cited by 4
Duque, A. L. M. D. S., Paula, D. P., de Paula, D., Molina, M. D. C. B., Giatii, L., Schmidt, M. I., da Fonseca, M. D. J. M., & Griep, R. H. (2025) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20250091i · Cited by 3
Diabetes and Disability: Medical, Social, and Legal Perspectives
Sen, A., Saxena, I., & Kaur, A. P. (2024) · Springer eBooks · doi:10.1007/978-3-031-40858-8_378-1 · Cited by 3
Nauck, M. A., Freckmann, G., & Heinemann, L. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241228538 · Cited by 2
Jospe, M. R., Kendall, M., Schembre, S. M., & Roy, M. (2025) · JMIR Formative Research · doi:10.2196/65368 · Cited by 3
Zhang, Z., Chen, H., Chen, L., Liang, W., Hu, T., Sun, N., Zhao, Y., & Wei, X. (2025) · Journal of Diabetes Investigation · doi:10.1111/jdi.70029 · Cited by 2
Alshalani, A., Alahmari, N., Amin, H. A., Aljedai, A., & AlSudais, H. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14155324 · Cited by 3
“Chronic hyperglycemia in T2DM contributes to structural and functional damage across multiple organ systems, particularly the cardiovascular, hepatic, and renal systems [11].”
Zheng, H., Zhou, W., Zeng, J., et al. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120673 · Cited by 2
Defining non-diabetic hypoglycemia: is there an appropriate plasma glucose threshold?
González‐Vidal, T., Delgado, E., & Torre, E. L. M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1496 · Cited by 2
Aljedai, A., Amin, H., Alanazi, F., AlSudais, H., & Alshalani, A. (2025) · International Journal of General Medicine · doi:10.2147/ijgm.s572310 · Cited by 2
The myokine musclin in metabolic syndrome: Pathological links and exercise interventions
Wen, R., Yang, Y., Wang, H., Teng, Y., Zhao, B., Zhu, H., & Wang, S. (2025) · iScience · doi:10.1016/j.isci.2025.114367 · Cited by 2
Ențuc, M., Bogdán, M., Boboc, I. K. Ş., Mititelu-Tarțău, L., Reurean‐Pintilei, D., Pavel, L. L., Pelin, A.-M., Spinei, A., & Foia, L. G. (2026) · Medicina · doi:10.3390/medicina62010152 · Cited by 3
“…is multifactorial and complex, influenced by a combination of genetic predisposition, impaired insulin secretion, insulin resistance, glucotoxicity, lipotoxicity, chronic low-grade inflammation, oxidative stress, and a decline in both the mass and function of pancreatic β -cells [17,18].”
Chang, S., LU, Y., Ling, H., Zhang, G., Zhang, Y., Li, X., & Ln, Z. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261416870 · Cited by 2
Perez-Belmonte, L. M., Prieto-Laín, N., Trenas, A., & Gómez-Huelgas, R. (2026) · Revista Clínica Española (English Edition) · doi:10.1016/j.rceng.2026.502491 · Cited by 3
Perez-Belmonte, L. M., Prieto-Laín, N., Trenas, A., & Gómez-Huelgas, R. (2026) · Revista Clínica Española · doi:10.1016/j.rce.2026.502491 · Cited by 2
Broul, M., Kelbich, P., Jizerová, A., Partlova, D., Hujová, A., & Liegertová, M. (2026) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2026.111148 · Cited by 2
Yuan, Y., Zhang, X., & Lin, K. (2024) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2024.e00414 · Cited by 2
“The guidelines for laboratory analysis of diabetes diagnosis recommend an intralaboratory CV ≤ 2.00 % and an interlaboratory CV ≤ 3.00 % [33,34].”
MethodInfluentialWang, Y., Yang, M., Wang, X., Zou, H., Chen, X., & Yuan, R. (2024) · Molecular Biotechnology · doi:10.1007/s12033-024-01210-w · Cited by 3
“Fasting blood glucose > 7 mM (126 mg/ dL) or blood glucose > 11.1 mM (200 mg/dL) after a 2 h load during an oral glucose tolerance test (OGTT) is an indicator of diabetes [33].”
InfluentialUrsu, M., Stuparu-Crețu, M., Gurău, G., Nitoi, L. C., Nechita, A., & Arbune, M. (2024) · Children · doi:10.3390/children11101162 · Cited by 3
Minimal mathematical model for glycation of albumin
Stickle, D. F., DiNatale, G. J., & Molinaro, R. J. (2024) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2024.110830 · Cited by 2
Rhode, S., Rogge, L., Marthoenis, M., Seuring, T., Zufry, H., Bärnighausen, T., Sofyan, H., Manne‐Goehler, J., & Vollmer, S. (2025) · Communications Medicine · doi:10.1038/s43856-025-00743-8 · Cited by 5
Milicic, T. J., Jotić, A., Lalic, K. S., Lukić, L., Macesic, M. V., Gajović, J. S., Stoiljkovic, M. M., Milovancevic, M. M., Rafailovic, D. P., Božović, A., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14041109 · Cited by 2
Elevated glucose levels in melanoma patients − a real-world analysis
Walter, J. E., Bojanic, B., Dittli, M., Fehr, N., Sartoretti, T., Schwyzer, M., Binz, K., Gennari, A. G., Ernst, M., Huellner, M. W., et al. (2025) · Journal of Clinical & Translational Endocrinology · doi:10.1016/j.jcte.2025.100405 · Cited by 2
Liu, T., Ma, X., & Duan, Z. (2025) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.5c03559 · Cited by 2
Gaylord‐King, C., Harris, C. L., Xu, S., Salerno, J. W., Walton, K. G., Bairey-Merz, C. N., Nidich, S. I., & Schneider, R. H. (2025) · Journal of Women s Health · doi:10.1177/15409996251364663 · Cited by 2
“37 Samples of venous blood were assayed by standard laboratory methods in line with the National Glycohemoglobin Standardization Program and the Diabetes Control and Complications Trial reference assay.”
InfluentialAssociation of TyG-related indices with incident DM among NAFLD patients: a retrospective study
He, Y., Fu, L., Gui, J., et al. (2025) · HORMONES · doi:10.1007/s42000-025-00710-x · Cited by 2
Kuleta, K., Krauz, K., Żmuda, J., Momot, K., Zarębiński, M., Poprawa, I., & Wojciechowska, M. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26199271 · Cited by 2
Kilpatrick, E. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad092 · Cited by 2
The Role of Continuous Glucose Monitoring in People without Diabetes: A US Perspective
Lee, C. H., & Naik, R. G. (2025) · Chronicle of Diabetes Research and Practice · doi:10.4103/cdrp.cdrp_16_24 · Cited by 2
Yang, M., Wang, W., Zhang, P., Liu, G., Lu, H., He, M., Deng, G., & Chen, X. (2024) · Infection and Drug Resistance · doi:10.2147/idr.s465075 · Cited by 3
Venous vs capillary glucose for gestational diabetes screening: a comparative study
Core, D. E., Root, M., Rodwig-Lousteau, A. A., et al. (2024) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2024.101443 · Cited by 1
Associations of glycated hemoglobin with hemoglobin levels and erythrocyte parameters
Dzis, Y., Tomashevska, O., Dzis, I., & Tomashevska, N. (2025) · INTERNATIONAL JOURNAL OF ENDOCRINOLOGY (Ukraine) · doi:10.22141/2224-0721.21.1.2025.1492 · Cited by 1
Monge, K. M., Guevara, A. N. R., Ruiz, N. H., Mendez, J. D. L. A., & Idrovo, J. (2025) · Cureus · doi:10.7759/cureus.81901 · Cited by 1
“In high-income countries like the US, structured prenatal care facilitates early GDM detection, counseling, and monitoring, while the infrastructure is often fragmented in Nicaragua [7].”
Akmalovna, G. I., Karimova, G. K., Subanova, G., Orzijonovna, N. N., Сайфиллоевна, Н. Н., Шопулатовна, О. Ф., Baxtiyarovna, S. T., Rysbaeva, A. Z., & Rahim, F. (2025) · Endocrine and Metabolic Science · doi:10.1016/j.endmts.2025.100252 · Cited by 2
Dias, R. J., Neves, J. S., & Poínhos, R. (2025) · Nutrients · doi:10.3390/nu17121951 · Cited by 1
Factores que interfieren en el resultado de la HbA1c
Merino, M. B., López, R. M., & Casado, L. N. (2025) · Atención Primaria · doi:10.1016/j.aprim.2025.103292 · Cited by 1
Current Practices in Gestational Diabetes
Palatnik, A., & Feghali, M. N. (2025) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/j.ogc.2025.05.008 · Cited by 1
Chen, X., Li, A., Du, L., Peng, J., & Ma, Q. (2025) · BMC Public Health · doi:10.1186/s12889-025-24113-0 · Cited by 2
“…oral hypoglycemic agents or insulin), fasting plasma glucose (FPG) levels of at least 7.0 mmol/L (at least 126 mg/dL), two-hour plasma glucose levels during an oral glucose tolerance test (OGTT) of at least 11.1 mmol/L (at least 200 mg/dL), or glycated hemoglobin A1c (HbA1c) of at least 6.5% [12].”
InfluentialHb Tacoma is difficult to detect and may cause false results with different HbA1c methods
Landin, B., Beshara, S., Eskils, J., Nilsson, M., Karlsson, S., Bark, N., & Bjellerup, P. (2025) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2025.2547317 · Cited by 1
A Precision Medicine Approach to the Care of Diabetes and Obesity in African Americans
Hall, G. L. (2025) · Springer eBooks · doi:10.1007/978-3-031-95774-1_5 · Cited by 1
Development of Mobile‐Phase Buffers and Evaluation of Analytical Performance for HbA1c Assays
Zhang, Y., Zhang, G., Yang, F., & Zou, Z. (2025) · Biomedical Chromatography · doi:10.1002/bmc.70136 · Cited by 1
Okoh, C. M., Moczygemba, L. R., Brown, C. M., Thurman, W., Avanceña, A. L. V., & Rush, S. K. (2025) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106251371085 · Cited by 1
Afridi, A. S., Kafy, M. A., Nur, F. N., Moon, N. N., Sefatullah, M., & Fareeha, E. (2025) · IEEE International Conference on Quantum Photonics, Artificial Intelligence & Networking (QPAIN) · doi:10.1109/qpain66474.2025.11172184 · Cited by 1
“[1] The American Heart Association reports that there are 115.9 million adults with pre-diabetes, 29.3 million adults with diagnosed diabetes, and 9.7 million adults with undiagnosed diabetes.”
InfluentialMorken, C., Hekland, J., Olausson, J., et al. (2025) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2025.2565732 · Cited by 1
“To diagnose, monitor and manage diabetes the measurement of glucose in blood is of essence [1].”
InfluentialZhao, W., Niu, X., Zhou, X., Shi, R., & Zhou, X. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-33885-4.00007-x · Cited by 1
Elevated fasting glucose is common in lung cancer patients undergoing 18F-FDG PET/CT: A brief report
Bojanic, B., Schwyzer, M., Sartoretti, T., Fischer, A., Binz, K., Hofer, G., Gennari, A. G., Ernst, M., Huellner, M. W., Walter, J. E., et al. (2025) · Metabolism Open · doi:10.1016/j.metop.2025.100406 · Cited by 1
“Importantly, for the formal diagnosis of diabetes, current guidelines recommend the measurement of fasting plasma glucose using venous plasma samples after at least 8 h of fasting [12].”
Synthesis of colloidal gold nano-structural systems for plasmonic glucose sensing
Neupane, G. P., & Salaria, R. K. (2025) · Discover Sensors · doi:10.1007/s44397-025-00021-1 · Cited by 1
Biosensors for detection of autoimmune disease
Karachaliou, C.-E., & Livaniou, E. (2025) · Advances in clinical chemistry · doi:10.1016/bs.acc.2025.10.004 · Cited by 1
Qiao, L., Miao, J., Du, W., Liu, Y., Chen, Y., Xu, K., Wang, C., & Chen, H. (2025) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2025.1688715 · Cited by 1
Magamba, B., Jonasson, J. M., & Agvall, B. (2025) · Scandinavian Journal of Primary Health Care · doi:10.1080/02813432.2025.2591340 · Cited by 2
“…into <52 mmol/mol, 52–70 mmol/mol and >70 mmol/mol and those having only a B-glucose were categorized to B-glucose <7.8 mmol/l and ≥7.8 mmol/l [23]. the inclusion of both HbA1c and blood glucose in the same category was done to account for patients who had only blood glucose measurements…”
InfluentialSeçkiner, S., Palamutoğlu, M. İ., Baş, D., İdiz, C., & Baş, M. (2025) · BMC Public Health · doi:10.1186/s12889-025-25948-3 · Cited by 1
“Diabetes Mellitus (DM) is a chronic disease that causes microvascular complications such as neuropathy, nephropathy, and retinopathy, as well as macrovascular complications that can result in cardiovascular and cerebrovascular events [1].”
Dzis, Y., Tomashevska, O., & Dzis, I. (2025) · Proceedings of the Shevchenko Scientific Society Medical Sciences · doi:10.25040/ntsh2025.02.09 · Cited by 1
Rodríguez‐Espinosa, D., Parra, R., Mataj, B., et al. (2026) · Transplant International · doi:10.3389/ti.2025.15872 · Cited by 1
“Notably, patients in our study were more likely to achieve a ≥ 30% reduction from baseline UACR, which represents the surrogate endpoint recommended by both the American Diabetes Association and the KDIGO guidelines [9, 10].”
Sayaca, N. A., & Sayaca, Ç. (2026) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-025-09947-z · Cited by 1
Kaur, S., Arnoldo, S., Taher, J., Bailey, D., Beach, L. A., Beriault, D. R., Bouhtiauy, I., Brun, M. M., Elnenaei, M. O., Huang, Y., et al. (2026) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2026.111100 · Cited by 1
From ordering to interpretation: a comprehensive framework for laboratory test indications
Weninger, J., Streichert, T., Coşkun, A., Pohl, M., Canbay, A. E., & Özcürümez, M. K. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1531 · Cited by 2
Zhou, L., Xie, D., Xu, S., et al. (2026) · Analytical Biochemistry · doi:10.1016/j.ab.2026.116117 · Cited by 1
Evaluation of Postpartum Glucose Tolerance Test Results Based on Criteria and Timing
Bastian, I. N., Gandhi, M., & TURRENTINE, M. A. (2026) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000006271 · Cited by 1
Ng, N. Y. H., Tsang, A. Y. T., Tam, C. H. T., Ng, K., Zhang, Y., Cheung, L. P., Chung, J. P., Chan, M. H. M., Ho, C., Kong, A. P. S., et al. (2026) · Fertility and Sterility · doi:10.1016/j.fertnstert.2026.03.035 · Cited by 1
Bencze, B., Cavalcante, B. G. N., Róna, V., et al. (2026) · BMC Oral Health · doi:10.1186/s12903-026-08366-8 · Cited by 1
“Diabetes mellitus (DM) is a group of chronic metabolic disorders characterized by hyperglycemia caused by impaired insulin production or action, leading to the underutilization of glucose as an energy source and over-production due to inappropriate gluconeogenesis and glycogenolysis [1].”
InfluentialHan, J., Yang, L., 褚勵丞, Lou, K., Zhang, Q., Wang, P., Shen, H., LI, J. L., & Bao, Z. (2026) · European Radiology · doi:10.1007/s00330-026-12574-9 · Cited by 1
Apsan, J., Gandhi, K. K., Rodriguez, J. P. P., Bianco, M. E., Bartz, S. K., & Chan, C. L. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.04.016 · Cited by 1
An AI framework for multi-disease detection via retinal imaging
(2026) · Nature Medicine · doi:10.1038/s41591-026-04424-4 · Cited by 1
An improved approach to modelling patient reclassification: HbA 1c as an example
Farrell, C.-J. L., Loh, T. P., Badrick, T. C., Jones, G. R. D., & Horvath, A. R. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0259 · Cited by 1
“Diabetes is diagnosed when HbA 1c is ≥ 6.5 % (48 mmol/mol), with con fi rmation testing on a di ff erent sample recommended [6 – 8].”
InfluentialSelf-citationPuerarin: A Potential Supplement for Diabetes and its Complications
Huai, B., Shen, Y., Huai, B., et al. (2024) · Endocrine Metabolic & Immune Disorders - Drug Targets · doi:10.2174/0118715303287050240223073217 · Cited by 1
Lu, H., & Wang, X. (2024) · BioTechniques · doi:10.1080/07366205.2024.2381403 · Cited by 1
Kaiser, P., Kramer, U., Rosenthal, H., Genz, C., Weiss, N., Schellenberg, I., & Spannagl, M. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0822 · Cited by 1
Impact of diabetes mellitus on 30-day mortality among acute stroke patients in northern Tanzania
Kamabu, E. M., Paluku, J. L., Howlett, W. P., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0321988 · Cited by 1
“Diabetes mellitus (DM) is a group of metabolic disorders of carbohydrate metabolism in which glucose is both underutilized as an energy source and overproduced due to inappropriate gluconeogenesis and glycogenolysis, resulting in hyperglycemia [1].”
Hlupeni, A., Liceralde, R. J., Obisesan, A., et al. (2025) · AACE Endocrinology and Diabetes · doi:10.1016/j.aed.2025.05.001 · Cited by 1
Lasio, M. L. D., Zaitsev, M. A., Hobert, J. A., Biase, I. D., Pasquali, M., & Yuzyuk, T. N. (2025) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2025.109160 · Cited by 1
Huang, D., Ma, J., Zhao, Y., et al. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1619370 · Cited by 1
Lima, R. P. E., Viana, K. S. S., Silva, P. G. B., Cota, L. O. M., & Costa, F. O. (2025) · Journal of Applied Oral Science · doi:10.1590/1678-7757-2025-0121 · Cited by 3
Diabetes in Pregnant Romanian Patients—Epidemiology and Prevention Strategies Proposal
Salmen, B.-M., Salmen, T., Reurean‐Pintilei, D., Vaida, C., & Bohîlțea, R. E. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14228135 · Cited by 1
“This group includes type 1 DM (T1DM), type 2 DM (T2DM), specific forms of DM due to specific causes (i.e., exocrine pancreas diseases, monogenic syndromes, chemical or drug-induced DM) and gestational DM (GDM) [1,2].”
Singh, P., Gonuguntla, S., Chen, E., Pradhan, A., Becker, I., Xu, N., Steel, B., Arkam, F., Yakdan, S. M., Naveed, H., et al. (2026) · medRxiv · doi:10.64898/2026.03.04.26347622 · Cited by 1
Do not report estimated average glucose (eAG) from HbA1c: Evidence is emerging
Chen, Y. (2023) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2023.110677
Ślusarczyk, M., Foryś, A., Kwaśniak, K., et al. (2024) · Quality in Sport · doi:10.12775/qs.2024.15.51865
Calixto, A. V. D., Amador, W. F. O., de Carvalho, V. M., Lima, M. R. D. A., de Assis, E. V., & de Lira, R. C. (2024) · Revista Foco · doi:10.54751/revistafoco.v17n7-055
Özbakan, A., & Erkoç, A. (2024) · Medical Records · doi:10.37990/medr.1522378
Glucose inhibitor tubes in Croatian laboratories: are we doing well?
Vrtarić, A., Gabaj, N. N., & Ćelap, I. (2024) · Biochemia Medica · doi:10.11613/bm.2024.030901
Cardozo, E. B. A., Vázquez, G. S. G., Viveros, G., Rolón, A. O., Méndez, J., & Galeano, D. (2024) · Revista de Nutrición Clínica y Metabolismo · doi:10.35454/rncm.v7n4.650
Arshad, M. A., Gautam, S. K., Giri, R., et al. (2025) · International Journal of Advances in Medicine · doi:10.18203/2349-3933.ijam20250373
Lee, W., Chen, H., Fang, C.-Y., Tsai, Y., Hsieh, Y.-Y., Chen, T., Fang, Y., Wu, P., Fang, H., & Liu, P. (2025) · Current Vascular Pharmacology · doi:10.2174/0115701611322555250219111038
Terreni, A., SiBioC, P. I. G. S. D. M. E. I. G. E. E. H., Mosca, A., et al. (2025) · Biochimica Clinica · doi:10.23736/s0393-0564.25.00006-8
Cardiac Manifestations in Children of Diabetic Mothers and Fathers
Huhulea, E. N., Huang, L., Aifuwa, E., Frishman, W. H., & Aronow, W. S. (2025) · Cardiology in Review · doi:10.1097/crd.0000000000000887
The effect of oral nutrition on diabetic ketoacidosis resolution time: Retrospective Cohort study
Can, B., & Karaali, Z. (2025) · Endocrine · doi:10.1007/s12020-025-04204-z
“Current guidelines and recommendations provide clear information for the management of this condition [2].”
Bonetti, G., Garzaniti, A., VUVAN, G., SALVADORI, S., ZALTIERI, G., & Carta, M. (2025) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.23736/s1825-859x.25.00277-4
Re-Think the Strip: de-implementing a low value practice in primary care
Donahue, K. E., Boynton, M. H., Leeman, J., Rees, J. R., Richman, E. L., MOTTUS, K. M., Spees, L. P., Vu, M. B., Reese, A., Tapp, H., et al. (2025) · BMC Family Practice · doi:10.1186/s12875-025-02781-6
“…(SMBG) is a recommended daily practice; push to reduce unnecessary SMBG testing as evidenced by the Choosing Wisely campaign [14] as well as the American Diabetes Association [15] which discourages routine SMBG among patients with non-insulin treated T2DM with moderately controlled A1c levels.”
Recent Advances in Blood Glucose Management for Diabetic Patients Undergoing Hemodialysis
苏, 俊. (2025) · Journal of Clinical Personalized Medicine · doi:10.12677/jcpm.2025.42237
Ozturk, O., Güzelbulut, F., Özdil, K., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14082618
“Diabetes was defined as HbA1c ≥ 6.5% (48 mmol/mol) or FPG ≥ 7.0 mmol/L (126 mg/dL) or 2 h plasma glucose ≥ 11.1 mmol/L (200 mg/dL) during an OGTT or in a patient with classic symptoms of hyperglycemia or hyperglycemic crisis, a random plasma glucose ≥ 11.1 mmol/L (200 mg/dL) [14].”
InfluentialHbA1c levels and breast cancer prognosis in women without diabetes
Holm, J. B., Bruun, J. M., Christiansen, P., et al. (2025) · BMC Cancer · doi:10.1186/s12885-025-14121-z
“Most studies included patients with pre-existing diabetes at baseline and used HbA 1c above diabetes cutoff (HbA 1c ≥ 48 mmol/mol [22]) as exposure [14, 15, 17–20], which does not provide a complete understanding of the role that pre-diabetic HbA 1c elevations play.”
Influential
Metadata
- Authors
- Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S.
- Affiliations
- National Institutes of Health (US)
- University of Iowa (US)
- American Heart Association (US)
- University of Virginia Medical Center (US)
- Prince of Wales Hospital (AU)
- Lund University (SE)
- Northwestern University (US)
- Harvard University (US)
- University of North Carolina at Chapel Hill (US)
- Corresponding author
- Sacks, David B.
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2023-07-20
- Volume
- 46
- Issue
- 10
- Pages
- e151-e199
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC10516260
- OpenAlex
- W4384924887
- Semantic Scholar
- 12804c77175645ab98b196f7dd81f97eb959d141
- Cited by
- 351
- References
- 535
- Citations by year
- 2026: 146 · 2025: 144 · 2024: 50 · 2023: 11
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes Care (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- Funders
- NIH Intramural Research Program
- Swedish Research Council
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- diabetes mellitus, diabetes diagnosis, glycemic control monitoring, HbA1c, venous plasma glucose, continuous glucose monitoring, self-monitoring of blood glucose, non-invasive glucose monitoring, genetic testing, autoantibodies, urinary albumin, insulin, proinsulin, C-peptide
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Insulin, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review