Cited by 351Diabetes Management and ResearchClinical Laboratory Practices and Quality ControlDiabetes and associated disorders

The DOI matches its Crossref record; 530 of the 535 references it cites were found in a registry or an index; 272 of the 502 sources its claims cite were checked for support.

Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus

Open access

Abstract

BACKGROUND: Numerous laboratory tests are used in the diagnosis and management of diabetes mellitus. The quality of the scientific evidence supporting the use of these assays varies substantially. APPROACH: An expert committee compiled evidence-based recommendations for laboratory analysis in screening, diagnosis, or monitoring of diabetes. The overall quality of the evidence and the strength of the recommendations were evaluated. The draft consensus recommendations were evaluated by invited reviewers and presented for public comment. Suggestions were incorporated as deemed appropriate by the authors (see Acknowledgments). The guidelines were reviewed by the Evidence Based Laboratory Medicine Committee and the Board of Directors of the American Association for Clinical Chemistry and by the Professional Practice Committee of the American Diabetes Association. CONTENT: Diabetes can be diagnosed by demonstrating increased concentrations of glucose in venous plasma or increased hemoglobin A1c (HbA1c) in the blood. Glycemic control is monitored by the people with diabetes measuring their own blood glucose with meters and/or with continuous interstitial glucose monitoring (CGM) devices and also by laboratory analysis of HbA1c. The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of ketones, autoantibodies, urine albumin, insulin, proinsulin, and C-peptide are addressed. SUMMARY: The guidelines provide specific recommendations based on published data or derived from expert consensus. Several analytes are found to have minimal clinical value at the present time, and measurement of them is not recommended.

Overview

Integrity signals

Registry

Crossref · 10.2337/dci23-0036

Cites

530 of 530 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

272 of 502 cited sources checked · 153 supported · 3 flagged · accuracy not yet measured

Show all 270 claims

  • It may state two separate claims as one. 120
  • Probably not a substantial claim. 76
178 of 178
  • The paper relies on this without support.

    HbA1c reflects long-term blood glucose concentrations.

    “recommended that diabetes could also be diagnosed by measurement of hemoglobin A 1c (HbA 1c ), which reflects long-term blood glucose concentrations”
  • The paper relies on this without support.

    The correlation between interstitial and blood glucose concentrations is usually high.

    “CGM devices have not been approved for use in hospitalized patients, in part due to concerns about accuracy, concomitant medication use, or theoretical alterations in the usually high correlation between interstitial and blood glucose concentrations caused by serious illness.”
  • The paper relies on this without support.

    The diagnosis of gestational diabetes mellitus is totally dependent on accurate measurement of glucose.

    “The diagnosis of GDM is totally dependent on accurate measurement of glucose.”
  • The paper relies on this without support.

    The renal glucose threshold is approximately 10 mmol/L (180 mg/dL).

    “it provides no information about blood glucose concentrations below the variable renal glucose threshold (approximately 10 mmol/L [180 mg/dL])”
  • The paper relies on this without support.

    Urine test reagents deteriorate with exposure to air, giving false-negative readings.

    “Urine test reagents deteriorate with exposure to air, giving false-negative readings; testing material should be stored in tightly sealed containers and discarded after the expiration date on the manufacturer's label.”
  • The paper relies on this without support.

    False-negative readings occur with highly acidic urine specimens, such as after large intakes of ascorbic acid.

    “False-negative readings have also been reported with highly acidic urine specimens, such as after large intakes of ascorbic acid.”
  • The paper relies on this without support.

    Loss of ketones from urine attributable to microbial action can cause false-negative readings.

    “Loss of ketones from urine attributable to microbial action can also cause false-negative readings.”
  • The paper relies on this without support.

    Acetone is a highly volatile substance.

    “Since acetone is a highly volatile substance, specimens should be kept in a closed container.”
  • The paper relies on this without support.

    The nitroprusside method measures only acetoacetate unless the reagent contains glycine, in which case acetone is also measured.

    “The nitroprusside method measures only AcAc unless the reagent contains glycine, in which case acetone is also measured.”
  • The paper relies on this without support.

    The nitroprusside-containing reagent is much more sensitive to acetoacetate than acetone with respect to color generation.

    “The nitroprussidecontaining reagent is much more sensitive to AcAc than acetone with respect to color generation.”
  • The paper relies on this without support.

    Resolution of acidosis or reduction in blood beta-hydroxybutyrate is traditionally the marker for successful treatment of diabetic ketoacidosis, rather than serial measurement of ketones by the nitroprusside reaction.

    “Resolution of acidosis or reduction in blood bOHB is traditionally the marker for successful treatment of DKA, rather than serial measurement of ketones by the nitroprusside reaction.”
  • The paper relies on this without support.

    Beta-hydroxybutyrate concentrations in healthy individuals fasted overnight are generally less than 0.5 mmol/L.

    “bOHB reference intervals differ among assay methods, but concentrations in healthy individuals fasted overnight are generally <0.5 mmol/L.”
  • The paper relies on this without support.

    Glycated hemoglobin usually indicates the average glucose concentration over the preceding 60 to 90 days.

    “Hemoglobin in the RBC has an average circulating life span of approximately 120 days, and glycated hemoglobin therefore usually indicates the average glucose concentration over the preceding 60 to 90 days.”
  • The paper relies on this without support.

    The clinical utility of glycated proteins other than hemoglobin has not been clearly established.

    “However, the clinical utility of glycated proteins other than hemoglobin has not been clearly established.”
  • The paper relies on this without support.

    HbA1c results are not significantly affected by acute fluctuations in blood glucose concentrations, such as those that occur with illness or after meals.

    “HbA 1c results are not significantly affected by acute fluctuations in blood glucose concentrations, such as those that occur with illness or after meals.”
  • The paper relies on this without support.

    Boronate affinity chromatographic assay methods are generally considered to be less affected by hemoglobin variants than other methods.

    “Boronate affinity chromatographic assay methods are generally considered to be less affected by hemoglobin variants than other methods.”
  • The paper relies on this without support.

    HbA1c cannot be measured in individuals with homozygous hemoglobin variants or two variant hemoglobins, like HbSC; they have no HbA and therefore do not have HbA1c.

    “It is important to emphasize that HbA 1c cannot be measured in individuals with homozygous hemoglobin variants (e.g., HbSS, HbCC, HbEE) or 2 variant hemoglobins, like HbSC; they have no HbA and therefore do not have HbA 1c .”
  • The paper relies on this without support.

    For most methods, whole blood samples stored at -70 C or colder are stable long term (at least 1 year), but specimens are not as stable at -20 C.

    “For most methods, whole blood samples stored at À70 C or colder are stable long term (at least 1 year), but specimens are not as stable at À20 C.”
  • The paper relies on this without support.

    There are more than 300 HbA1c assay methods in current clinical use.

    “There are >300 HbA 1c assay methods in current clinical use.”
  • The paper relies on this without support.

    The two IFCC methods use the same primary reference materials and the results are essentially identical.

    “The two methods use the same primary reference materials and the results are essentially identical.”
  • The paper relies on this without support.

    The preparation and measurement of samples using the IFCC method is laborious, expensive, and time-consuming and was never envisioned as a practical means of assaying clinical samples.

    “Of note, the preparation and measurement of samples using this method is laborious, expensive, and time-consuming and was never envisioned as a practical means of assaying clinical samples.”
  • The paper relies on this without support.

    Currently available automated assays either remove the labile pre-HbA1c during the assay process or do not measure the labile product.

    “Currently available automated assays either remove the labile pre-HbA 1c during the assay process or do not measure the labile product.”
  • The paper relies on this without support.

    HbA1c values in people with diabetes are a continuum, ranging from within the nondiabetic reference interval in a small percentage of people to markedly increased values in some individuals.

    “HbA 1c values in people with diabetes are a continuum; they range from within the nondiabetic reference interval in a small percentage of people whose mean plasma glucose concentrations are close to those of individuals without diabetes, to markedly increased values, e.g., two-to threefold higher levels than the nondiabetic mean of approximately 5%, in some individuals, reflecting extreme hypergly”
  • The paper relies on this without support.

    Type 1 diabetes results from a selective autoimmune destruction of the pancreatic b-cell functional mass, eventually leading to an absolute lack of insulin and consequent hyperglycemia.

    “Type 1 diabetes results from a selective autoimmune destruction of the pancreatic b-cell functional mass, eventually leading to an absolute lack of insulin and consequent hyperglycemia.”
  • The paper relies on this without support.

    Type 1 diabetes is genetically linked to HLA of the major histocompatibility complex (MHC) on chromosome 6.

    “Type 1 diabetes is genetically linked to HLA of the major histocompatibility complex (MHC) on chromosome 6.”
  • The paper relies on this without support.

    Type 1 or autoimmune diabetes is strongly associated with HLA DR and DQ genes.

    “Type 1 or autoimmune diabetes is strongly associated with HLA DR and DQ genes.”
  • The paper relies on this without support.

    Mutation detection for MODY is technically feasible.

    “Mutation detection for MODY is technically feasible.”
  • The paper relies on this without support.

    The pathogenesis of type 1 diabetes is strongly associated with several immune abnormalities most prominently islet autoantibodies but also cooccurrence of other organ-specific autoimmune diseases such as autoimmune thyroid disease and celiac disease.

    “The pathogenesis of type 1 diabetes is strongly associated with several immune abnormalities most prominently islet autoantibodies but also cooccurrence of other organ-specific autoimmune diseases such as autoimmune thyroid disease and celiac disease.”
  • The paper relies on this without support.

    The clinical onset of type 1 diabetes is related to the loss of the functional b-cell mass.

    “The clinical onset of type 1 diabetes is related to the loss of the functional b-cell mass.”
  • The paper relies on this without support.

    Insulin treatment precludes the analysis of IAA as it takes only about 11 days before insulin antibodies are induced.

    “Insulin treatment precludes the analysis of IAA as it takes only about 11 days before insulin antibodies are induced.”
  • The paper relies on this without support.

    Islet autoantibodies are found in the general population.

    “Islet autoantibodies are found in the general population.”
  • The paper relies on this without support.

    Excessive albumin excretion in the urine is directly related to future loss of kidney function and increased cardiovascular risk.

    “it is well known that excessive albumin excretion in the urine is directly related to future loss of kidney function and increased cardiovascular risk”
  • The paper relies on this without support.

    The onset of type 2 diabetes is difficult to date precisely.

    “the difficulty in precisely dating the onset of type 2 diabetes”
  • The paper relies on this without support.

    Race is a social, not biologic, construct.

    “race is a social, not biologic, construct”
  • The paper relies on this without support.

    Clear inequities occur with use of race-based equations for eGFR.

    “clear inequities occur with use of race-based equations for eGFR”
  • The paper relies on this without support.

    Cystatin C assays are not widely available in the U.S.

    “cystatin C assays are not widely available in the U.S.”
  • The paper relies on this without support.

    Insulin resistance plays a critical role in the pathogenesis of type 2 diabetes.

    “Due to the critical role of insulin resistance in the pathogenesis of type 2 diabetes”
  • The paper relies on this without support.

    Accurate measurement of insulin resistance requires complex methods generally confined to research laboratories.

    “accurate measurement of insulin resistance requires the use of complex methods, such as the hyperinsulinemiceuglycemic clamp technique, which are generally confined to research laboratories”
  • The paper relies on this without support.

    Clinical operators do not wait the full time between dipping and scanning.

    “perhaps because they do not wait the full time (usually 60 s) between dipping and scanning”
  • The paper relies on this without support.

    Effective screening tests have low false-negative rates.

    “Effective screening tests (e.g., for phenylketonuria) have low false-negative rates.”
  • The paper relies on this without support.

    The normal rate of GFR loss is about 0.8 mL/min/year in diabetes.

    “the normal rate of GFR loss is about 0.8 mL/min/year in diabetes”
41 of 41

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • The stated 5.6 mmol/L interval uses the wrong percentage

    Minor

    A range of 4.9 to 6.3 mmol/L is approximately 5.6 mmol/L ±12.5%, not ±6.4%. Applying 6.4% gives about 5.2 to 6.0 mmol/L.

  • The stated 7.0 mmol/L interval uses the wrong percentage

    Minor

    A range of 6.1 to 7.9 mmol/L is approximately 7.0 mmol/L ±12.9%, not ±6.4%. Applying the stated 6.4% gives about 6.6 to 7.4 mmol/L.

  • The same IFCC value is assigned to two different HbA1c percentages

    Minor

    The reference-interval discussion equates 31 mmol/mol with both 5% and 5.6% HbA1c. Those percentages cannot both represent the same IFCC value.

3 of 3

Citations

Cites

Flagged first, then by citations

Show all 535 references

5 of the 535 references couldn’t be matched to a known paper.

Research works printed but not linked: 7

  1. Ladenson, 1980, Nonanalytical sources of variation in clinical chemistry results, 149
  2. Rifai, 2017, Carbohydrates
  3. Sacks, 2023, Carbohydrates, 353.e1
  4. Sacks, 2023, Diabetes mellitus, 502
  5. Little, 1998, A simple blood collection device for analysis of glycohemoglobin (GHB), Clin Chem, 44, A139
  6. Goldstein, 1997, Bringing order to chaos: the National Glycohemoglobin Standardization Program, Contemp Intern Med, 9, 27
  7. Sacks, 2020, Participant Summary for Hemoglobin A1c Survey 2020 Set GH5-C

Cited by

Sorted by citations

Items 101–200 of 334

Metadata

Authors
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S.
Affiliations
  • National Institutes of Health (US)
  • University of Iowa (US)
  • American Heart Association (US)
  • University of Virginia Medical Center (US)
  • Prince of Wales Hospital (AU)
  • Lund University (SE)
  • Northwestern University (US)
  • Harvard University (US)
  • University of North Carolina at Chapel Hill (US)
Corresponding author
Sacks, David B.
Venue
Diabetes Care
Published
2023-07-20
Volume
46
Issue
10
Pages
e151-e199
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W4384924887
Cited by
351
References
535
Citations by year
2026: 146 · 2025: 144 · 2024: 50 · 2023: 11
FWCI
12.60
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion, public-domain)
  • PubMed Central (publishedVersion, public-domain)
  • PubMed (publishedVersion)
  • Lund University Publications (Lund University) (submittedVersion)
Funders
  • NIH Intramural Research Program
  • Swedish Research Council
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
diabetes mellitus, diabetes diagnosis, glycemic control monitoring, HbA1c, venous plasma glucose, continuous glucose monitoring, self-monitoring of blood glucose, non-invasive glucose monitoring, genetic testing, autoantibodies, urinary albumin, insulin, proinsulin, C-peptide
MeSH terms
Blood Glucose, Diabetes Mellitus, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Insulin, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review