Continuous Glucose Monitoring
The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring provides maximal information about shifting blood glucose levels throughout the day and facilitates the making of optimal treatment decisions for the diabetic patient. This report discusses continuous glucose monitoring in terms of its purposes, technologies, target populations, accuracy, clinical indications, outcomes, and problems. In this context, the medical literature on continuous glucose monitoring available through the end of 2004 is reviewed. Continuous glucose monitoring provides information about the direction, magnitude, duration, frequency, and causes of fluctuations in blood glucose levels. Compared with conventional intensified glucose monitoring, defined as three to four blood glucose measurements per day, continuous monitoring provides much greater insight into glucose levels throughout the day. Continuous glucose readings that supply trend information can help identify and prevent unwanted periods of hypo- and hyperglycemia. The difference between an intermittent and a continuous monitor for monitoring blood glucose is similar to that between a regular camera and a continuous security camera for monitoring an important situation. A regular camera takes discrete, accurate snapshots; its pictures do not predict the future; it produces a small set of pictures that can all be carefully studied; and effort is required to take each picture. A continuous security camera, on the other hand, takes multiple, poorly focused frames; displays a sequential array of frames whose trend predicts the future; produces too much information for each frame to be studied carefully; and operates automatically after it is turned on. The two types of blood glucose monitors differ in much the same way: 1 ) an intermittent blood glucose monitor measures discrete glucose levels extremely accurately, whereas a continuous monitor provides multiple glucose levels of fair accuracy; 2 ) with an intermittent monitor, current blood glucose levels do not predict future glucose levels, but with a continuous monitor, trends in glucose levels do have …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s106 · Cited by 988
Limitations of Conventional Methods of Self-Monitoring of Blood Glucose
Boland, E., Monsod, T., Delucia, M., Brandt, C. A., Fernando, S., & Tamborlane, W. V. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1858 · Cited by 423
Ryan, E. A., Shandro, T., Green, K., Paty, B. W., Senior, P. A., Bigam, D., Shapiro, A. M. J., & Vantyghem, M.-C. (2004) · Diabetes · doi:10.2337/diabetes.53.4.955 · Cited by 343
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312
Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., Young-Hyman, D., Schlundt, D., & Clarke, W. (1998) · Diabetes Care · doi:10.2337/diacare.21.11.1870 · Cited by 310
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303
Physiological Differences Between Interstitial Glucose and Blood Glucose Measured in Human Subjects
Kulcu, E., Tamada, J. A., Reach, G., Potts, R. O., & Lesho, M. J. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2405 · Cited by 251
Glucose monitoring by reverse iontophoresis
Potts, R. O., A. Tamada, J., & J. Tierney, M. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 243
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235
Cited by
Monnier, L., Mas, E., Ginet, C., Michel, F., Villon, L., Cristol, J.-P., & Colette, C. (2006) · JAMA · doi:10.1001/jama.295.14.1681 · Cited by 2,444
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Epidemiology of type 1 diabetes
Maahs, D. M., West, N. A., Lawrence, J. M., & Mayer-Davis, E. J. (2010) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2010.05.011 · Cited by 1,092
Little, J. P., Gillen, J. B., Percival, M. E., Safdar, A., Tarnopolsky, M. A., Punthakee, Z., Jung, M. E., & Gibala, M. J. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00921.2011 · Cited by 787
“CGM provides information about direction, magnitude, and frequency of blood glucose excursions and may provide a sensitive means to detect acute changes in blood glucose throughout the day (15).”
BackgroundIn Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Monnier, L., Colette, C., Dunseath, G. J., & Owens, D. R. (2007) · Diabetes Care · doi:10.2337/dc06-1612 · Cited by 490
Hovorka, R., Allen, J. M., Elleri, D., Chassin, L. J., Harris, J., Xing, D., Kollman, C., Hovorka, T., Larsen, A. M. F., Nodale, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61998-x · Cited by 450
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S., Zisser, H., Schwartz, S., Bailey, T., Kaplan, R., Ellis, S., & Jovanovic, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 433
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358
“Novel methods of continuous glucose monitoring provide up to 288 measurements a day.”
MethodClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Sparacino, G., Zanderigo, F., Corazza, S., Maran, A., Facchinetti, A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889774 · Cited by 338
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
AAPS-FDA Workshop White Paper: Microdialysis Principles, Application and Regulatory Perspectives
Chaurasia, C. S., Müller, M., Bashaw, E. D., Benfeldt, E., Bolinder, J., Bullock, R., Bungay, P. M., DeLange, E. C. M., Derendorf, H., Elmquist, W. F., et al. (2007) · Pharmaceutical Research · doi:10.1007/s11095-006-9206-z · Cited by 316
Tanenbaum, M. L., Hanes, S. J., Miller, K. M., Naranjo, D., Bensen, R., & Hood, K. K. (2017) · Diabetes Care · doi:10.2337/dc16-1536 · Cited by 296
Monnier, L., Colette, C., & Owens, D. R. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200618 · Cited by 294
Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring
Shibata, H., Heo, Y. J., Okitsu, T., Matsunaga, Y., Kawanishi, T., & Takeuchi, S. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006911107 · Cited by 287
Current development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Deep Learning for Diabetes: A Systematic Review
Zhu, T., Li, K., Herrero, P., & Georgiou, P. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3040225 · Cited by 264
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244
“Since early 2000, improved tools for managing type 1 diabetes have emerged. These include continuous glucose monitors and increasingly sophisticated insulin pumps. Continuous glucose monitors measure interstitial glucose levels and, although less accurate than conventional monitoring by finger stick testing, they offe…”
BackgroundWearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment
Cappon, G., Acciaroli, G., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2017) · Electronics · doi:10.3390/electronics6030065 · Cited by 237
Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234
Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System
Weinstein, R. L., Schwartz, S. L., Brazg, R. L., Bugler, J. R., Peyser, T. A., & McGarraugh, G. V. (2007) · Diabetes Care · doi:10.2337/dc06-1602 · Cited by 228
In situ monitoring of health in older adults: technologies and issues
Kang, H. G., Mahoney, D. F., Hoenig, H., Hirth, V. A., Bonato, P., Hajjar, I., Lipsitz, L. A., & for the Center for Integration of Medicine and Innovative Technology Working Group on Advanced Approaches to Physiologic Monitoring for the Aged (2010) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2010.02959.x · Cited by 227
Polymer thin films embedded with metal nanoparticles for electrochemical biosensors applications
Prakash, S., Chakrabarty, T., Singh, A. K., & Shahi, V. K. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.09.031 · Cited by 218
Georga, E. I., Protopappas, V. C., Ardigo, D., Marina, M., Zavaroni, I., Polyzos, D., & Fotiadis, D. I. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/titb.2012.2219876 · Cited by 216
Rizzo, M. R., Marfella, R., Barbieri, M., Boccardi, V., Vestini, F., Lettieri, B., Canonico, S., & Paolisso, G. (2010) · Diabetes Care · doi:10.2337/dc10-0389 · Cited by 212
Fokkert, M. J., van Dijk, P. R., Edens, M. A., Abbes, S., de Jong, D., Slingerland, R. J., & Bilo, H. J. G. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000320 · Cited by 209
Mechanisms of hypoglycemia unawareness and implications in diabetic patients
Martín-Timón, I. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i7.912 · Cited by 204
Kovatchev, B. P., Clarke, W. L., Breton, M., Brayman, K., & McCall, A. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.849 · Cited by 201
Model-based blood glucose control for type 1 diabetes via parametric programming
Dua, P., Doyle, F. J., & Pistikopoulos, E. N. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.878075 · Cited by 198
“monitor the glucose concentration [6].”
Military applications of soldier physiological monitoring
Friedl, K. E. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.06.004 · Cited by 194
Continuous Glucose Monitoring: Real-Time Algorithms for Calibration, Filtering, and Alarms
Bequette, B. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400222 · Cited by 192
Neural Network-Based Real-Time Prediction of Glucose in Patients with Insulin-Dependent Diabetes
Pappada, S. M., Cameron, B. D., Rosman, P. M., Bourey, R. E., Papadimos, T. J., Olorunto, W., & Borst, M. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0104 · Cited by 182
Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals
Gough, D. A., Kumosa, L. S., Routh, T. L., Lin, J. T., & Lucisano, J. Y. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001148 · Cited by 179
Analysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors
Breton, M., & Kovatchev, B. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200517 · Cited by 173
Yu, F., Lv, L., Liang, Z., Wang, Y., Wen, J., Lin, X., Zhou, Y., Mai, C., & Niu, J. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-4332 · Cited by 162
Bailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159
Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198034 · Cited by 158
Closed-Loop Basal Insulin Delivery Over 36 Hours in Adolescents With Type 1 Diabetes
Elleri, D., Allen, J. M., Kumareswaran, K., Leelarathna, L., Nodale, M., Caldwell, K., Cheng, P., Kollman, C., Haidar, A., Murphy, H. R., et al. (2013) · Diabetes Care · doi:10.2337/dc12-0816 · Cited by 158
“Coupling subcutaneous continuous glucose monitoring (2,3) and insulin pump delivery (4), the closed-loop technology delivers insulin in a continually glucose-responsive fashion to reduce the risk of hypoglycemia and to improve overall glucose control (5,6).”
BackgroundChanges in the glycemic profiles of women with type 1 and type 2 diabetes during pregnancy
Murphy, H. R., Rayman, G., Duffield, K., Lewis, K. S., Kelly, S., Johal, B., Fowler, D., & Temple, R. C. (2007) · Diabetes Care · doi:10.2337/dc07-0500 · Cited by 138
Optimal use of diabetes devices: clinician perspectives on barriers and adherence to device use
Tanenbaum, M. L., Adams, R. N., Hanes, S. J., Barley, R. C., Miller, K. M., Mulvaney, S. A., & Hood, K. K. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816688010 · Cited by 117
Exercise-related hypoglycemia in diabetes mellitus
Younk, L. M., Mikeladze, M., Tate, D., & Davis, S. N. (2011) · Expert Review of Endocrinology & Metabolism · doi:10.1586/eem.10.78 · Cited by 114
“3 The Diabetes Control and Complications Trial Research Group.”
BackgroundInfluentialRatzki-Leewing, A., Harris, S. B., Mequanint, S., Reichert, S. M., Belle Brown, J., Black, J. E., & Ryan, B. L. (2018) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2017-000503 · Cited by 90
Sartore, G., Chilelli, N. C., Burlina, S., Stefano, P. D., Piarulli, F., Fedele, D., Mosca, A., & Lapolla, A. (2012) · Acta Diabetologica · doi:10.1007/s00592-012-0391-4 · Cited by 90
Imai, S., Fukui, M., & Kajiyama, S. (2014) · Journal of Clinical Biochemistry and Nutrition · doi:10.3164/jcbn.13-67 · Cited by 81
Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy
Clarke, W. L., & Kovatchev, B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100510 · Cited by 71
“Such systems have three basic components: (1) a glucose sensor, (2) an automated insulin delivery device (insulin pump), and (3) a set of control algorithms that utilize sensor data and other information to direct the delivery of insulin.”
Paramasivam, S. S., Chinna, K., Singh, A. K. K., Ratnasingam, J., Ibrahim, L., Lim, L. L., Tan, A. T. B., Chan, S. P., Tan, P. C., Omar, S. Z., et al. (2018) · Diabetic Medicine · doi:10.1111/dme.13649 · Cited by 69
Facchinetti, A., Favero, S., Sparacino, G., & Cobelli, C. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2227256 · Cited by 62
Modeling Glucose Transport From Systemic Circulation to Sweat
La Count, T. D., Jajack, A., Heikenfeld, J., & Kasting, G. B. (2019) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2018.09.026 · Cited by 60
Fit‐for‐Purpose Biometric Monitoring Technologies: Leveraging the Laboratory Biomarker Experience
Godfrey, A., Vandendriessche, B., Bakker, J. P., Fitzer‐Attas, C., Gujar, N., Hobbs, M., Liu, Q., Northcott, C. A., Parks, V., Wood, W. A., et al. (2021) · Clinical and Translational Science · doi:10.1111/cts.12865 · Cited by 60
In vivo evaluation of a chip based near infrared sensor for continuous glucose monitoring
Ben Mohammadi, L., Klotzbuecher, T., Sigloch, S., Welzel, K., Göddel, M., Pieber, T. R., & Schaupp, L. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.043 · Cited by 46
Enhancing the longevity of microparticle-based glucose sensors towards 1 month continuous operation
Singh, S., & McShane, M. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.026 · Cited by 35
“Recently, continuous glucose monitoring systems (CGMS) based on highly selective enzyme electrodes have been made available commercially; these sensors are inserted through the skin, much like an infusion set for an insulin pump (Klonoff 2005).”
Bajgrowicz-Cieslak, M., Alqurashi, Y., Elshereif, M. I., Yetisen, A. K., Hassan, M. U., & Butt, H. (2017) · RSC Advances · doi:10.1039/c7ra11184c · Cited by 32
High performance boronic acid-containing hydrogel for biocompatible continuous glucose monitoring
Dou, Q., Hu, D., Gao, H., Zhang, Y., Yetisen, A. K., Butt, H., Wang, J., Nie, G., & Dai, Q. (2017) · RSC Advances · doi:10.1039/c7ra06965k · Cited by 31
Kalyani, R. R., Allende-Vigo, M. Z., Antinori-Lent, K. J., Close, K. L., Das, S. R., Deroze, P., Edelman, S. V., El Sayed, N. A., Kerr, D., Neumiller, J. J., et al. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad745 · Cited by 25
Continuous Glucose Monitoring During Pregnancy in Women With Polycystic Ovary Syndrome
Dmitrovic, R., Katcher, H. I., Kunselman, A. R., & Legro, R. S. (2011) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e31822c887f · Cited by 23
ZHU, J., TENG, Y., ZHOU, J., LU, W., TAO, M., & JIA, W. (2013) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1111/aogs.12031 · Cited by 23
“Continuous glucose monitoring measures interstitial subcutaneous tissue glucose levels continuously, recording values every five minutes (20,21), and providing a much more detailed surveillance of blood glucose levels throughout the day (22).”
BackgroundModeling Glucagon Action in Patients With Type 1 Diabetes
Emami, A., Youssef, J. E., Rabasa-Lhoret, R., Pineau, J., Castle, J. R., & Haidar, A. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2593630 · Cited by 20
“Recent developments in continuous glucose sensors and subcutaneous infusion pumps have motivated the research toward closed-loop systems, often coined as the “artificial pancreas,” that automatically regulate glucose levels for patients with T1D [9].”
BackgroundInfluentialRecent advances in computational tools and resources for the self-management of type 2 diabetes
Moonian, O., Jodheea-Jutton, A., Khedo, K. K., Baichoo, S., Nagowah, S. D., Nagowah, L., Mungloo-Dilmohamud, Z., & Cheerkoot-Jalim, S. (2020) · Informatics for Health and Social Care · doi:10.1080/17538157.2018.1559168 · Cited by 15
“23,24 GlucoWatch 25 was the first real-time CGM system that was approved by the Food and Drug Administration (FDA) and which uses a reversed iontophoresis to measure interstitial glucose.”
Method
Metadata
- Authors
- Klonoff, D. C.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2005-05-01
- Volume
- 28
- Issue
- 5
- Pages
- 1231-1239
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2111485734
- Cited by
- 724
- References
- 80
- FWCI
- 22.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.