Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Open accessThe DOI matches its Crossref record; 286 of the 289 references it cites were found in a registry or an index; 74 of the 284 sources its claims cite were checked for support.
Abstract
Functionalized hydrogels are intrinsically conductive, self-healing, self-adhesive, biocompatible, and room-temperature sensitive.
Overview
CoChat Summary
TL;DR
This review summarizes how hydrogel properties are optimized for wearable gas and humidity sensors, and how these devices work for monitoring gases such as NO2, NH3, O2, CO2, and explosives, as well as humidity. It argues that hydrogels are promising because they can be stretchable, conductive, self-healing, and room-temperature operable, but the field is still in its early stages.
Key findings
- Hydrogels can be engineered for wearable sensing by improving mechanical deformability, conductivity, anti-freezing/water retention, self-healing, biocompatibility, self-adhesion, and transparency.
- For gas sensing, the review highlights reported examples with specific performance values, including NO2 detection limits as low as 4.1 ppb, 1.2 ppb, 0.1 ppb, and 2.23 ppb; NH3 detection limits as low as 0.42 ppm, 0.07 ppm, 0.5 ppm, 50 ppb, and 92 ppb; O2 detection limit as low as 5.7 ppm; and CO2 detection limit of 20 ppm in one hydrogel sensor example.
- For humidity sensing, hydrogels show strong swelling-based and conductivity-based responses, with reported sensitivities including 13,462.1% RH%−1, 78,785.5% RH%−1, and 25,000 to 98% RH operation in one sensor example.
- The review says hydrogel-based wearable sensors have been used for environmental monitoring, healthcare, respiratory monitoring, electronic skin, and wireless monitoring, but still need better selectivity, stability, standardization, and integration.
Methods
- This is a review article, not an experimental study; it systematically summarizes published work on functionalized hydrogel-based wearable gas and humidity sensors.
- The paper organizes the literature by hydrogel design/optimization and by application area: gas sensing, humidity sensing, and wearable use cases such as respiratory monitoring and e-skin.
- Its synthesis is based on reported studies and their performance parameters, with tables and example devices used to compare sensing mechanisms and outcomes.
Limitations
- The paper explicitly states that research on hydrogel-based vapor sensors is still in its infancy and that many practical problems remain.
- It says the gas- and humidity-sensing mechanisms are not yet unified or fully understood, and that factors such as electrode properties, crosslinking method, crosslinking density, and conductivity need further study.
- It notes that most gas-sensor work focuses on NO2, NH3, and O2, so other gases still need exploration.
- Evident from the text: this is a narrative review rather than a systematic meta-analysis, so its comparisons are descriptive and depend on the cited studies rather than a standardized pooled evaluation.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures

![Fig. 2 a Schematic of the synthesis of tetra-PEG hydrogel. Reproduced with permission [111]. Copyright 2008, American Chemical Society. b Schematic of the synthesis of DN hydrogels. c Schematic diagram of the synthesis of clay NPs/PNIPAMNC. Reproduced with permission [112]. Copyright 2002, Wiley‐VCH](https://figures.cochat.ai/paper-figures/72093ab1b68c459d8ea4ddaec1e74bf2/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-2.jpg)
![Fig. 3 Main approaches for producing conductive hydrogels. Reproduced with permission [127]. Copyright 2020, Royal Society of Chemistry](https://figures.cochat.ai/paper-figures/7b38192bcd7b4090a9ca09fec386da2c/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-3.jpg)
![Fig. 4 a Encapulation: a1 Schematic diagram of elastomer encapsulated hydrogel; a2 Variation of the weight ratio of hydrogel and hydrogel-elastomer hybrid with time. Reproduced with permission [151]. Copyright 2016, Springer Nature. b Adding hygroscopic salts: b1 Schematic structure of LiBr-PAM/Carr DN hydrogel; b2 Trends in weight of hydrogels with different concentrations of LiBr content over time under room temperature drying environment; b3 DSC spectra of these hydrogels. Reproduced with permission [152]. Copyright 2022, Springer Nature. c Organohydrogel: c1-c2 Schematic diagram of PVA/CNF-Gly preparation method; c3 DSC spectra of the organohydrogels with different CNF contents; c4 Weight trends over time for organic hydrogels with different CNF contents under high temperature and dry conditions. Reproduced with permission [67]. Copyright 2022, Wiley‐VCH](https://figures.cochat.ai/paper-figures/c927de4fce194dd78597af64cfcf985e/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-4.jpg)

![Fig. 6 a Schematic of a simple hydrogel-based gas sensor and its sensing process. Reproduced with permission [67]. Copyright 2023, Wiley‐VCH. b Schematic of the sensing mechanism of hydrogel for NO2 sensing. c SEM image of the Ag anode after prolonged NO2 sensing, indicating the generation of an AgCl layer. d Schematic of the electrode-masking experimental setup. e Real-time current curves of the hydrogel sensor for different NO2 concentrations when the anode or cathode is encapsulated. f Dynamic response curves of the hydrogel sensors with different numbers of Ag electrode turns to different NO2 concentrations. Reproduced with permission [150]. Copyright 2021, Wiley‐VCH. g Effect of anode material change on the sensitivity of hydrogel-based NO2 sensors. Reproduced with permission [69]. Copyright 2022, Royal Society of Chemistry](https://figures.cochat.ai/paper-figures/9018ea86ab934ee1978b6e934929b453/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-6.jpg)
![Fig. 7 a-d Complex impedance plots of the PAA/GA sensor at different humidity values with or without 50 ppm NH3. e Complex impedance plot of the PAA/GA sensor with different NH3 concentrations at 80% RH. f Impedance modulus of the PAA/GA sensors with and without 50 ppm NH3 at different humidity levels. NH3 sensing mechanism of PAA/GA: g at low RH values, h at moderate RH values, and i at high RH values. Reproduced with permission [72]. Copyright 2021, Elsevier](https://figures.cochat.ai/paper-figures/9b88534d02fa4a6491aa2e74bb95e284/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-7.jpg)
![Fig. 8 a Schematic diagram of the selectivity of SnO2/RGOH for NO2. b Diagram of microheater. Reproduced with permission [210]. Copyright 2020, American Chemical Society. c Comparison of the response ability of the original hydrogel and the self-healed hydrogel to NO2. Reproduced with permission [150]. Copyright 2021, Wiley‐VCH. d Schematic of wireless sensing and alarm for NO2. d1-d4 Sensor alarm process for 2 ppm NO2: when the current exceeds the threshold, the red light comes on and the buzzer sounds. d5-d7 Wireless reception of NO2 sensing signals on a smartphone. Reproduced with permission [69]. Copyright 2022, Royal Society of Chemistry. e Real‐time responses of the PVA–CNF DN organohydrogel towards 0.4–2 ppm NO2 at 25, − 10 and − 20 °C. Reproduced with permission [67]. Copyright 2022, Wiley‐VCH. f Structure of self-powered NO2 sensor/power source. g Schematic diagram of self-powered NO2 sensing system. Reproduced with permission [214]. Copyright 2023, Wiley‐VCH](https://figures.cochat.ai/paper-figures/65b1ccfd19bc4de8ac82e3d54b78031c/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-8.jpg)
![Fig. 9 a Response of PAM/CArr DN hydrogel to NH3 in different tensile strains. Reproduced with permission [70]. Copyright 2020, American Chemical Society. b Response (purple column) of PAA/GA sensor to NH3 and other interfering gases. Reproduced with permission [72]. Copyright 2021, Elsevier. c-d NH3 sensing mechanism of PGA/GA sensors: c at low RH values and b at high RH values. Reproduced with permission [71]. Copyright 2020, Elsevierc. e Diagram of the breath testing process for NH3. f Response of hydrogels to exhalation with different NH3 contents. Reproduced with permission [76]. Copyright 2021, Elsevier](https://figures.cochat.ai/paper-figures/0475d7cd26b346dabbafd058c77cc0cc/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-9.jpg)
![Fig. 10 a1 Response to 1% O2 under different tensile strains. a2 Response of original and self-healed organohydrogels to 1% O2. a3 Photographs showing the organohydrogel (marked by the yellow circle) adhered firmly to various materials. a4 Real-time response curve of the sensor to human exhalation in the air. a5 Diagram of the breath testing process for O2. Reproduced with permission [77]. Copyright 2022, Springer Nature. SEM of b1 PI film and b2 hydrogel on artificial skin. b3 Schematic diagram of the tcPO2 sensing device and sensing process. b4 Illustration of placing the sensor on the foot to measure tcPO2. b5-b6 Test results of tcPO2 sensing when the foot is in different states. Reproduced with permission [230]. Copyright 2021, American Association for the Advancement of Science](https://figures.cochat.ai/paper-figures/365b662363f54a78bc8aa1a16c7897d5/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-10.jpg)
![Fig. 11 a-c Diagram of the human olfactory system for olfactory signal transmission. d-f Diagram of the sensing process of the colorimetric hydrogel sensor on the target substance. g Structure and h fabrication of colorimetric hydrogel sensor. Reproduced with permission [250]. Copyright 2020, Wiley–VCH](https://figures.cochat.ai/paper-figures/46866d2d50b846828c9bf29765d9b5bb/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-11.jpg)
![Fig. 12 a Swelling/contraction of CS hydrogel under different humidity conditions. Reproduced with permission [267]. Copyright 2022, American Association for the Advancement of Science. b–d Complex EIS spectra of the humidity sensor under different RH environments. e Dynamic response curves of the thin-film and bulk hydrogels at different RH values. f Variations in the thickness of hydrogel with the spin-coating speed. g Dynamic response curves of the hydrogel films of different thicknesses at different RH values. Reproduced with permission [206]. Copyright 2022, Springer Nature](https://figures.cochat.ai/paper-figures/a0342b1580234e33b5f2c4b2802148cf/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-12.jpg)
![Fig.13 a Optical responses (reflection spectra) of hydrogel sensors in different RH values. b CIE 1931 color space of the XY values converted from the reflection spectra. c Hydrogel sensors for high-resolution displays: the color of the display changes with the ambient humidity. Reproduced with permission [267]. Copyright 2022, American Association for the Advancement of Science. d Responses of the DN hydrogel and EG/Gly-DN organohydrogels to different RH values. e Response of the Gly-DN organohydrogel to low RH values. f Response/recovery time of respiration monitoring. Reproduced with permission [270]. Copyright 2019, Royal Society of Chemistry](https://figures.cochat.ai/paper-figures/9873a3304f064203aeeffefeec1a5ac5/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-13.jpg)
![Fig. 14 Response of the humidity sensor to a regular and b irregular breath. Response to c finger bending, d knee bending at different frequency, e pulse at the wrist and f vocal cord vibration. Reproduced with permission [276]. Copyright 2021, Elsevier. g CGCN sensors identify different patterns of breathing. h Bending finger and i touching intermittently at – 25 °C. Reproduced with permission [78]. Copyright 2021, Elsevier](https://figures.cochat.ai/paper-figures/40cb5ad376ae467299aaddd6327ddb22/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-14.jpg)
![Fig. 15 a1 Comparison of humidity response of film and block hydrogels. a2 Comparison of the response of different sensitive sources. Reproduced with permission [152]. Copyright 2022, Springer Nature. b1 Comparison of the response of different sensitive sources. b2 Schematic diagram of the handheld breath test. b3 Real-time response curve of handheld breath test in different breathing modes. b4 Schematic diagram of the mask breathing test. b5 Real-time response curve of the mask breathing test in different breathing modes. Reproduced with permission [277]. Copyright 2023, Wiley‐VCH. c1-c2 Monitoring of “normal breathing” and “apnea” with smart masks. Reproduced with permission [206]. Copyright 2022, Springer Nature](https://figures.cochat.ai/paper-figures/ac2e3f2673bc418babd183a8a0bd4a15/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-15.jpg)
![Fig. 16 a Output voltage of I-skin at different RH. b Humidity sensitivity of I-skin. c Output voltage of I-skin at 99% RH and 20% RH alternately. d Output voltage variation curve of I-skin under different breathing modes. e Diagram of finger distance perception by I-skin through humidity change. f Variation of output voltage of I-skin at different finger distances. Reproduced with permission [79]. Copyright 2022, American Chemical Society](https://figures.cochat.ai/paper-figures/c8dffc38ba494fb0a5ebbec97965cfc6/functionalized-hydrogel-based-wearable-gas-and-humidity-sensors-figure-16.jpg)
Verification
Claims the paper makes
58 Valid · 11 Not valid · 136 Not checked · 82 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“flammable and explosive gases, such as H2 and CH4, pose a direct threat to the safety of human life and property”
§ Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors > Introduction
What the sources say
- Not checked — no full text of the sourcecites [12] Park K-R Cho H-B Lee J Song Y Kim W-B Design of highly porous SnO2-CuO nanotubes for enhancing H2S gas sensor performance Sens. Actuator B Chem. 2020 302 127179 10.1016/j.snb.2019.127179 source
- Not checked — no full text of the sourcecites [13] Liu X Qiao S Ma Y Highly sensitive methane detection based on light-induced thermoelastic spectroscopy with a 2.33 µm diode laser and adaptive Savitzky-Golay filtering Opt. Express 2022 30 1304 10.1364/OE.446294 35209293 source
- Not checked — no full text of the sourcecites [14] Mishra GP Kumar D Chaudhary VS Kumar S Design and sensitivity improvement of microstructured-core photonic crystal fiber based sensor for methane and hydrogen fluoride detection IEEE Sens. J. 2022 22 1265 10.1109/JSEN.2021.3131694 source
- Not checked — no full text of the sourcecites [15] Chen Y Xu P Li X Ren Y Deng Y High-performance H2 sensors with selectively hydrophobic micro-plate for self-aligned upload of Pd nanodots modified mesoporous In2O3 sensing-material Sens. Actuator B Chem. 2018 267 83 10.1016/j.snb.2018.03.180 source
- Partly supportedcites [16] Lee J-H Kim J-H Kim J-Y Mirzaei A Kim HW Ppb-level selective hydrogen gas detection of Pd-functionalized In2O3-loaded ZnO nanofiber gas sensors Sensors 2019 19 4276 10.3390/s19194276 31581664 PMC6806323 sourceExperimental — accuracy not yet measured
The Introduction describes H2 as highly flammable and says an unexpected leak can be catastrophic. It does not address CH4 or its threat to life and property, so the claim is supported only for H2. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [17] Dong C Jiang M Tao Y Shen Y Lu Y Nonaqueous synthesis of Pd-functionalized SnO2/In2O3 nanocomposites for excellent butane sensing properties Sens. Actuator B Chem. 2018 257 419 10.1016/j.snb.2017.10.175 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“synthetic hydrogels with enhanced mechanical deformability and controlled structure and degradation, such as polyethylene glycol (PEG), polyvinyl alcohol (PVA), poly(2-hydroxyethyl methacrylate) (PHEMA) and polyacrylamide (PAM), can be used in sensors, actuators, soft robots, and wastewater treatment”
§ Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors > Design and Optimization of Hydrogels Hydrogels are classified based on their properties. According to the source, hydrogels can be divided into natural and synthetic hydrogels [85–87]. Natural hydrogels, such as collagen, chitosan (CS), hyaluronic acid, alginate, gelatin, elastin, chondroitin sulfate, and heparin, have excellent biocompatibility, and are used in a wide range of applications, such as bioengineering, medical health, and food processing [88–94]. Nonetheless, their unsatisfactory mechanical deformability, uncontrollable structure, and degradation limit their broader spectrum of applications [48, 49]. Meanwhile, synthetic hydrogels with enhanced mechanical deformability and controlled structure and degradation, such as polyethylene glycol (PEG), polyvinyl alcohol (PVA), poly(2-hydroxyethyl methacrylate) (PHEMA) and polyacrylamide (PAM), can be used in sensors, actuators, soft robots, and wastewater treatment [95–101]. However, synthetic hydrogels have lower biocompatibility than that of natural hydrogels, making them unsuited for health-related applications [48, 49]. According to the different methods of crosslinking polymer chains, they can be divided into physically and chemically crosslinked hydrogels [85–87]. Physically crosslinked hydrogels are formed by various strong/weak intermolecular interactions between polymer chains and usually have poor mechanical deformability, which limit their applications [102–104]. In contrast, chemically crosslinked hydrogels are crosslinked by covalent bonding between polymer chains, resulting in superior mechanical deformability [105–107]. However, the degradation of biocompatibility owing to the residual chemical crosslinkers, organic solvents, and photoinitiators in chemically crosslinked hydrogels limit their usage in biomedical-related applications. Based on the practical application of wearable vapor sensors, large deformability, long-term stability, conductivity, self-healing, high responsiveness, and biocompatibility are desired. As different hydrogels have their own advantages and disadvantages, simple hydrogels cannot meet these complex requirements for stretchable and wearable vapor sensors. Hence, simple hydrogels should be optimized and modified to meet practical application demands. In the recent decades, important advances have focused on the preparation of hydrogels with the modulation of their properties, such as porosity, biocompatibility, electrical conductivity, and mechanical deformability, by different design and optimization approaches to meet different application requirements. In this section, we will briefly introduce some inherent and functionalized properties of hydrogels, and the corresponding design and optimization approaches from the application requirements of flexible wearable vapor sensors to provide possible theoretical support for the design and preparation of gas/humidity sensors for personal health and safety monitoring.
What the sources say
- Not checked — no full text of the sourcecites [95] Liu J Wang H Ou R Yi X Liu T Anti-bacterial silk-based hydrogels for multifunctional electrical skin with mechanical-thermal dual sensitive integration Chem. Eng. J. 2021 426 130722 10.1016/j.cej.2021.130722 source
- Partly supportedcites [96] Liu X Yang Y Inda ME Lin S Wu J Magnetic living hydrogels for intestinal localization, retention, and diagnosis Adv. Funct. Mater. 2021 31 2010918 10.1002/adfm.202010918 35903441 PMC9328153 sourceExperimental — accuracy not yet measured
The Results and Discussion section describes a PVA magnetic hydrogel with low stiffness and high toughness, and the Abstract reports its use to carry intestinal sensors. The paper does not establish the claimed properties or applications for PEG, PHEMA, or PAM, nor does it address controlled degradation, soft robots, or wastewater treatment. Page numbers are unavailable in our copy. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [97] Shin MK Spinks GM Shin SR Kim SI Kim SJ Nanocomposite hydrogel with high toughness for bioactuators Adv. Mater. 2009 21 1712 10.1002/adma.200802205 source
- Partly supportedcites [98] Liu L Jiang S Sun Y Agarwal S Giving direction to motion and surface with ultra-fast speed using oriented hydrogel fibers Adv. Funct. Mater. 2016 26 1021 10.1002/adfm.201503612 sourceExperimental — accuracy not yet measured
Our copy supports only the actuator/deformation part of the claim: the Abstract and Introduction describe thermoresponsive hydrogel (PNIPAM) bilayer/fibrous actuators undergoing large reversible swelling-driven shape changes, with applications listed as 'encapsulation, microfabrication, robotics, smart drug carrier' and tissue engineering. Nothing in our copy mentions the four named polymers PEG, PVA, PHEMA or PAM (the only hydrogel used is cross-linked P(NIPAM-ABP) with a TPU passive layer), nor controlled structure and degradation, sensors, soft robots as such, or wastewater treatment (searched: 'polyethylene glycol PEG polyvinyl alcohol PVA PHEMA polyacrylamide', 'wastewater treatment adsorption sensors soft robots biodegradable degradation'). The sweeping background statement is therefore only partly carried by this source, and the polymer list, degradation control, sensor and wastewater-treatment applications are unsupported. (LLM, conf=0.62)
- Partly supportedcites [99] Odent J Vanderstappen S Toncheva A Pichon E Wallin TJ Hierarchical chemomechanical encoding of multi-responsive hydrogel actuators via 3D printing J. Mater. Chem. A 2019 7 15395 10.1039/C9TA03547H sourceExperimental — accuracy not yet measured
Our copy supports only the actuator/controlled-structure part of the claim: the Abstract and Conclusions describe 3D-printed multi-responsive hydrogel actuators with anisotropic swelling, 'rapid and controllable motion' and tunable structure (surface-area-to-volume ratio, crosslinking density, composition). The specific polymer classes the claim attributes to this source — PEG, PVA, PHEMA and PAM — do not appear anywhere in our copy; the paper's hydrogels are PNIPAM and PCEA with MBA crosslinker (Materials; Design and 3D printing of gradient-like structures). Nor does our copy address controlled degradation, sensors, soft robots or wastewater treatment — the applications discussion is limited to bending actuation and gripper demonstrations (Fig. 5) plus a generic 'wide range of technological applications' (Conclusions). (LLM, conf=0.72)
- Partly supportedcites [100] Liu J Lin S Liu X Qin Z Yang Y Fatigue-resistant adhesion of hydrogels Nat. Commun. 2020 11 1071 10.1038/s41467-020-14871-3 32103027 PMC7044439 sourceExperimental — accuracy not yet measured
The Introduction and Results describe PVA hydrogels with tunable crystallinity and use polyacrylamide hydrogels as controls. The Discussion proposes durable hydrogel coatings for devices, including interfaces with robots. Our copy does not support the full list of PEG and PHEMA, controlled degradation, or the claimed uses in sensors, actuators, soft robots, and wastewater treatment. (LLM, conf=0.86)
- Partly supportedcites [101] Lei H Dong L Li Y Zhang J Chen H Stretchable hydrogels with low hysteresis and anti-fatigue fracture based on polyprotein cross-linkers Nat. Commun. 2020 11 4032 10.1038/s41467-020-17877-z 32788575 PMC7423981 sourceExperimental — accuracy not yet measured
The Discussion (page not specified) reports highly stretchable engineered hydrogels and identifies sensors, actuators, and soft robotics as potential applications. The Results describe PEG- and polyacrylamide-based hydrogels, but the cited passages do not support the inclusion of PVA or PHEMA, controlled degradation, or wastewater treatment. (LLM, conf=0.87)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“hydrogels can be functionalized to achieve specific properties and structures”
§ Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors > Introduction
What the sources say
- Not checked — no full text of the sourcecites [64] Huang W Cheng S Wang X Zhang Y Chen L Noncompressible hemostasis and bone regeneration induced by an absorbable bioadhesive self-healing hydrogel Adv. Funct. Mater. 2021 31 2009189 10.1002/adfm.202009189 source
- Supportedcites [65] Caló E Khutoryanskiy VV Biomedical applications of hydrogels: A review of patents and commercial products Eur. Polym. J. 2015 65 252 10.1016/j.eurpolymj.2014.11.024 source
The Introduction (Sec. 1) states that hydrogel networks 'may be charged or non-charged depending on the nature of functional groups present in their structure', and that these groups dictate swelling and shape-response behaviour, i.e. properties set by the chemistry introduced into the network. The review repeatedly illustrates functionalization to obtain particular structures and properties: derivatized phenylboronate ligands complexed with poly(vinyl alcohol) to give saccharide-degradable cell-culture scaffolds (Sec. 5, Kumar), AgNO3-incorporated nanofibre networks with 'unique mechanical properties and adjustable swelling ratios' for antimicrobial wound dressings (Sec. 3), and stimuli-responsive cross-linked copolymers for self-regulated drug delivery (Sec. 4). The wording 'functionalized' is not used verbatim, but our copy clearly treats the topic that way, so the broad background claim is supported. (LLM, conf=0.85)
- Supportedcites [66] Thoniyot P Tan MJ Karim AA Young DJ Loh XJ Nanoparticle–hydrogel composites: Concept, design, and applications of these promising, multi-functional materials Adv. Sci. 2015 2 1400010 10.1002/advs.201400010 PMC5115280 27980900 source
The Introduction says that combining nanoparticles with hydrogels generates structural diversity and property enhancements. The Design, Synthesis, and Properties section gives examples of changing gel morphology and tuning properties through nanoparticle cross-linking. No page numbers are provided in our copy. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“During the stretching of DN hydrogels, the mechanical energy is dissipated by sacrificing the breakage of chemical bonds in the densely crosslinked polymer network, or by the perturbation of non-covalent interactions, thereby improving the mechanical deformability of the hydrogel”
§ Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors > Design and Optimization of Hydrogels Hydrogels are classified based on their properties. According to the source, hydrogels can be divided into natural and synthetic hydrogels [85–87]. Natural hydrogels, such as collagen, chitosan (CS), hyaluronic acid, alginate, gelatin, elastin, chondroitin sulfate, and heparin, have excellent biocompatibility, and are used in a wide range of applications, such as bioengineering, medical health, and food processing [88–94]. Nonetheless, their unsatisfactory mechanical deformability, uncontrollable structure, and degradation limit their broader spectrum of applications [48, 49]. Meanwhile, synthetic hydrogels with enhanced mechanical deformability and controlled structure and degradation, such as polyethylene glycol (PEG), polyvinyl alcohol (PVA), poly(2-hydroxyethyl methacrylate) (PHEMA) and polyacrylamide (PAM), can be used in sensors, actuators, soft robots, and wastewater treatment [95–101]. However, synthetic hydrogels have lower biocompatibility than that of natural hydrogels, making them unsuited for health-related applications [48, 49]. According to the different methods of crosslinking polymer chains, they can be divided into physically and chemically crosslinked hydrogels [85–87]. Physically crosslinked hydrogels are formed by various strong/weak intermolecular interactions between polymer chains and usually have poor mechanical deformability, which limit their applications [102–104]. In contrast, chemically crosslinked hydrogels are crosslinked by covalent bonding between polymer chains, resulting in superior mechanical deformability [105–107]. However, the degradation of biocompatibility owing to the residual chemical crosslinkers, organic solvents, and photoinitiators in chemically crosslinked hydrogels limit their usage in biomedical-related applications. Based on the practical application of wearable vapor sensors, large deformability, long-term stability, conductivity, self-healing, high responsiveness, and biocompatibility are desired. As different hydrogels have their own advantages and disadvantages, simple hydrogels cannot meet these complex requirements for stretchable and wearable vapor sensors. Hence, simple hydrogels should be optimized and modified to meet practical application demands. In the recent decades, important advances have focused on the preparation of hydrogels with the modulation of their properties, such as porosity, biocompatibility, electrical conductivity, and mechanical deformability, by different design and optimization approaches to meet different application requirements. In this section, we will briefly introduce some inherent and functionalized properties of hydrogels, and the corresponding design and optimization approaches from the application requirements of flexible wearable vapor sensors to provide possible theoretical support for the design and preparation of gas/humidity sensors for personal health and safety monitoring. > Mechanical Deformability
What the sources say
- Not checked — no full text of the sourcecites [123] Chimene D Kaunas R Gaharwar AK Hydrogel bioink reinforcement for additive manufacturing: a focused review of emerging strategies Adv. Mater. 2020 32 1902026 10.1002/adma.201902026 31599073 source
- Supportedcites [124] Sun TL Kurokawa T Kuroda S Ihsan AB Akasaki T Physical hydrogels composed of polyampholytes demonstrate high toughness and viscoelasticity Nat. Mater. 2013 12 932 10.1038/nmat3713 23892784 source
Split into 2 atoms — 2 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
- Not checked — no full text of the sourcecites [125] Xia S Song S Gao G Robust and flexible strain sensors based on dual physically cross-linked double network hydrogels for monitoring human-motion Chem. Eng. J. 2018 354 817 10.1016/j.cej.2018.08.053 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“The biodegradability of the hydrogels can be regulated by adjusting the PACG/Gelma ratio”
§ Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors > Design and Optimization of Hydrogels Hydrogels are classified based on their properties. According to the source, hydrogels can be divided into natural and synthetic hydrogels [85–87]. Natural hydrogels, such as collagen, chitosan (CS), hyaluronic acid, alginate, gelatin, elastin, chondroitin sulfate, and heparin, have excellent biocompatibility, and are used in a wide range of applications, such as bioengineering, medical health, and food processing [88–94]. Nonetheless, their unsatisfactory mechanical deformability, uncontrollable structure, and degradation limit their broader spectrum of applications [48, 49]. Meanwhile, synthetic hydrogels with enhanced mechanical deformability and controlled structure and degradation, such as polyethylene glycol (PEG), polyvinyl alcohol (PVA), poly(2-hydroxyethyl methacrylate) (PHEMA) and polyacrylamide (PAM), can be used in sensors, actuators, soft robots, and wastewater treatment [95–101]. However, synthetic hydrogels have lower biocompatibility than that of natural hydrogels, making them unsuited for health-related applications [48, 49]. According to the different methods of crosslinking polymer chains, they can be divided into physically and chemically crosslinked hydrogels [85–87]. Physically crosslinked hydrogels are formed by various strong/weak intermolecular interactions between polymer chains and usually have poor mechanical deformability, which limit their applications [102–104]. In contrast, chemically crosslinked hydrogels are crosslinked by covalent bonding between polymer chains, resulting in superior mechanical deformability [105–107]. However, the degradation of biocompatibility owing to the residual chemical crosslinkers, organic solvents, and photoinitiators in chemically crosslinked hydrogels limit their usage in biomedical-related applications. Based on the practical application of wearable vapor sensors, large deformability, long-term stability, conductivity, self-healing, high responsiveness, and biocompatibility are desired. As different hydrogels have their own advantages and disadvantages, simple hydrogels cannot meet these complex requirements for stretchable and wearable vapor sensors. Hence, simple hydrogels should be optimized and modified to meet practical application demands. In the recent decades, important advances have focused on the preparation of hydrogels with the modulation of their properties, such as porosity, biocompatibility, electrical conductivity, and mechanical deformability, by different design and optimization approaches to meet different application requirements. In this section, we will briefly introduce some inherent and functionalized properties of hydrogels, and the corresponding design and optimization approaches from the application requirements of flexible wearable vapor sensors to provide possible theoretical support for the design and preparation of gas/humidity sensors for personal health and safety monitoring. > Other Properties
What the sources say
- Supportedcites [200] Gao F Xu Z Liang Q Li H Peng L Osteochondral regeneration with 3d-printed biodegradable high-strength supramolecular polymer reinforced-gelatin hydrogel scaffolds Adv. Sci. 2019 6 1900867 10.1002/advs.201900867 PMC6685475 31406678 source
The Results and Discussion section (Preparation and Characterization of PACG-GelMA Hydrogels, Figure 2) reports that changing ACG or GelMA content changes the hydrogels’ degradation rate. This supports regulating biodegradability through their formulation ratio; the reported degradation test was conducted in collagenase solution. (LLM, conf=0.92)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
108 more claims · 18 with their cited sources checked
Create a free account to see all 287 claims and to verify the 30 references still open.
- It may state two separate claims as one. 159
- Probably not a substantial claim. 29
- The quote only partly states this claim. 1
Citations
Cites
Items 201–286 of 286
Chemically functionalized 3D graphene hydrogel for high performance gas sensing
Wu, J., Tao, K., Zhang, J., Guo, Y., Miao, J., & Norford, L. K. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta01426g · Cited by 117 · cited 1×
“Wu et al. [74] have developed a hydrogel material that can directly respond to CO 2 .”
BackgroundSelf-citationHong, S. Y., Oh, J. H., Park, H., Yun, J. Y., Jin, S. W., Sun, L., Zi, G., & Ha, J. S. (2017) · NPG Asia Materials · doi:10.1038/am.2017.194 · Cited by 117 · cited 1×
“Only more than 35 ppm of NH 3 is sufficient to potentially destroy the human sensory and respiratory systems [216, 217].”
BackgroundKotani, R., Yokoyama, S., Nobusue, S., Yamaguchi, S., Osuka, A., Yabu, H., & Saito, S. (2022) · Nature Communications · doi:10.1038/s41467-022-27972-y · Cited by 117
Hierarchical chemomechanical encoding of multi-responsive hydrogel actuators via 3D printing
Odent, J., Vanderstappen, S., Toncheva, A., Pichon, E., Wallin, T. J., Wang, K., Shepherd, R. F., Dubois, P., & Raquez, J.-M. (2019) · Journal of Materials Chemistry A · doi:10.1039/c9ta03547h · Cited by 115
Mishra, G. P., Kumar, D., Chaudhary, V. S., & Kumar, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3131694 · Cited by 114
Hydrogel-Based Gas Sensors for NO 2 and NH 3
Zhi, H., Gao, J., & Feng, L. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02383 · Cited by 108 · cited 1×
“Zhi et al. [68] prepared NH 3 and NO 2 hydrogel gas sensors based on PVA and CA double networks with the response of 31.60%, response/recovery times of 46/9 s for 40 ppm NH 3 and low LODs of 140.85 ppb while being stretchable.”
MethodInfluentialDing, Q., Wang, H., Zhou, Z., Wu, Z., Tao, K., Gui, X., Liu, C., Shi, W., & Wu, J. (2023) · SmartMat · doi:10.1002/smm2.1147 · Cited by 107 · cited 1×
“With the benefit of ultra-high humidity response, this hydrogel sensor exhibits relatively good humidity selectivity, but still Ding et al. [277] developed a humidity-sensitive ionic skin composed of PVA/CNF organohydrogel film with controllable thickness prepared by a simple combined one-pot and…”
BackgroundSelf-citationJiang, T., Munguia-Lopez, J. G., Gu, K., Bavoux, M. M., Flores-Torres, S., Kort-Mascort, J., Grant, J., Vijayakumar, S., De Leon-Rodriguez, A., Ehrlicher, A. J., et al. (2020) · Biofabrication · doi:10.1088/1758-5090/ab3a5c · Cited by 106 · cited 1×
“Finally, the conceivable future research trends for hydrogel gas/humidity sensing are discussed. biocompatibility, and are used in a wide range of applications, such as bioengineering, medical health, and food processing [88–94].”
BackgroundUltra-sensitive polyaniline–iron oxide nanocomposite room temperature flexible ammonia sensor
Bandgar, D. K., Navale, S. T., Naushad, M., et al. (2015) · RSC Advances · doi:10.1039/c5ra11512d · Cited by 104
Elshaarani, T., Yu, H., Wang, L., Zain‐ul‐Abdin, Z., Ullah, R. S., Haroon, M., Khan, R. U., Fahad, S., Khan, A., Nazir, A., et al. (2018) · Journal of Materials Chemistry B · doi:10.1039/c7tb03332j · Cited by 104 · cited 1×
“…chemical reaction to generate a phenylboronic ester complexation; thiol/disulfide bond exchange reaction that form a dynamic covalent bond disulfide bond; and the amine bond Schiff base formed by the nucleophilic attack of the amine on the aldehyde group as a dynamic covalent bond [190–197].”
BackgroundWu, J., Wu, Z., Ding, H., Wei, Y., Huang, W., Yang, X., Li, Z., Qiu, L., & Wang, X. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b18098 · Cited by 104 · cited 1×
“To further increase the selectivity of hydrogel-based gas sensors for NO 2 , Wu et al. [210] prepared a three-dimensional graphene hydrogel modified with SnO 2 (SnO 2 /RGOH).”
BackgroundSelf-citationHumidity-activated ammonia sensor with excellent selectivity for exhaled breath analysis
Liu, L., Fei, T., Guan, X., Zhao, H., & Zhang, T. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129625 · Cited by 100 · cited 2×
“Zhang et al. [72] explored the role of RH in the sensing properties of hydrogel-based gas sensors.”
BackgroundAntifreeze and moisturizing high conductivity PEDOT/PVA hydrogels for wearable motion sensor
Peng, Y., Yan, B., Li, Y., Lan, J., Shi, L., & Ran, R. (2019) · Journal of Materials Science · doi:10.1007/s10853-019-04101-7 · Cited by 98
A Colorimetric Artificial Olfactory System for Airborne Improvised Explosive Identification
Wang, G., Li, Y., Cai, Z., & Dou, X. (2020) · Advanced Materials · doi:10.1002/adma.201907043 · Cited by 98
Gas-sensing selectivity of n-ZnO/p-Co3O4 sensors for homogeneous reducing gas
Nie, S., Dastan, D., Li, J., Zhou, W.-D., Wu, S.-S., Zhou, Y.-W., & Yin, X.-T. (2021) · Journal of Physics and Chemistry of Solids · doi:10.1016/j.jpcs.2020.109864 · Cited by 97
Self-citationWu, Z., Rong, L., Yang, J., Wei, Y., Tao, K., Zhou, Y., Yang, B., Xie, X., & Wu, J. (2021) · Small · doi:10.1002/smll.202104997 · Cited by 97
Self-citationLiu, X., Qiao, S., & Ma, Y. (2022) · Optics Express · doi:10.1364/oe.446294 · Cited by 97
Zhang, J., Wang, X.-X., Zhang, B., Ramakrishna, S., Yu, M., Ma, J.-W., & Long, Y.-Z. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b01718 · Cited by 96 · cited 1×
“By monitoring the concentration of water vapor, the identification of respiratory characteristics can also be achieved to further predict sleep apnea, asthma, anemia and other chronic lung diseases for the early detection and treatment [273–275].”
BackgroundZhang, W., Ma, J., Zhang, W., Zhang, P., He, W., Chen, J., & Sun, Z. (2020) · Nanoscale · doi:10.1039/d0nr01414a · Cited by 96
Enhanced ammonia sensing at room temperature with reduced graphene oxide/tin oxide hybrid films
Ghosh, R., Nayak, A. K., Santra, S., Pradhan, D., & Guha, P. K. (2015) · RSC Advances · doi:10.1039/c5ra06696d · Cited by 95 · cited 1×
“Although it has a pun-gent odor, it is easily detectable only when its concentration is higher than 50 ppm [215].”
BackgroundGao, Y., Jia, F., & Gao, G. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132919 · Cited by 95 · cited 1×
“[78] prepared an organohydrogel film (CGGN) with only 0.”
MethodProperties of conductive polymer hydrogels and their application in sensors
Guo, B., Ma, Z., Pan, L., & Shi, Y. (2019) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.24899 · Cited by 94
Gold-loaded tellurium nanobelts gas sensor for ppt-level NO2 detection at room temperature
Yuan, Z., Zhao, Q., Xie, C., Liang, J., Duan, X., Duan, Z., Li, S., Jiang, Y., & Tai, H. (2022) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.131300 · Cited by 93
Chen, Y., Tan, Z., Wang, W., Peng, Y., & Narain, R. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b01652 · Cited by 92
Ultrasensitive reversible oxygen sensing by using liquid-exfoliated MoS 2 nanoparticles
Kim, Y. H., Kim, K. Y., Choi, Y. R., Shim, Y.-S., Jeon, J.-M., Lee, J.-H., Kim, S. Y., Han, S., & Jang, H. W. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta01277a · Cited by 90
Development of Adhesive and Conductive Resilin-Based Hydrogels for Wearable Sensors
Hu, X., Xia, X.-X., Huang, S.-C., & Qian, Z.-G. (2019) · Biomacromolecules · doi:10.1021/acs.biomac.9b00389 · Cited by 88
Wu, J., Wei, Y., Ding, H., Wu, Z., Yang, X., Li, Z., Huang, W., Xie, X., Tao, K., & Wang, X. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c00578 · Cited by 86 · cited 1×
“Wu and his team [209] improved their previous study by choosing to use green, non-polluting vitamin C (VC) as a modifier for the reduced graphene oxide hydrogel (V-RGOH).”
BackgroundSelf-citationOxygen and anesthesia: what lung do we deliver to the post‐operative ward?
HEDENSTIERNA, G. (2012) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2012.02689.x · Cited by 85 · cited 2×
“When the oxygen concentration is below 12%, there is even a risk of death by asphyxiation [224, 225].”
BackgroundHigh strength, antifreeze, and moisturizing conductive hydrogel for human‐motion detection
Peng, Y., Pi, M., Zhang, X., Yan, B., Li, Y., Shi, L., & Ran, R. (2020) · Polymer · doi:10.1016/j.polymer.2020.122469 · Cited by 85
Zheng, Y., Wang, Y., Li, Z., Yuan, Z., Guo, S., Lou, Z., Han, W., Shen, G., & Wang, L. (2022) · Matter · doi:10.1016/j.matt.2022.11.020 · Cited by 84 · cited 1×
“For portable and wearable sensors, flexible and wearable electronic systems have received copious attention because of their huge potential applications in human–machine interfaces, health monitoring, and smart skins for robots [27–36].”
BackgroundMechanical properties of a polymer network of Tetra-PEG gel
SUGIMURA, A., Asai, M., Matsunaga, T., Akagi, Y., Sakai, T., Noguchi, H., & Shibayama, M. (2012) · Polymer Journal · doi:10.1038/pj.2012.149 · Cited by 79 · cited 1×
“In their subsequent 1 3 studies, the importance of the homogeneity of polymer crosslinking in enhancing the mechanical deformability of hydrogels was demonstrated [116, 117].”
BackgroundWu, J., Wu, Z., Huang, W., Yang, X., Liang, Y., Tao, K., Yang, B.-R., Shi, W., & Xie, X. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c17669 · Cited by 79 · cited 1×
“Afterwards, they introduced ethylene glycol (Eg) modification on the basis of PAM/CArr DN hydrogel to prepare NH3 and NO2 hydrogel gas sensors that can operate at room temperature [70].”
MethodSelf-citationAn, R., Zhang, B., Han, L., Wang, X., Zhang, Y., Shi, L., & Ran, R. (2019) · Journal of Materials Science · doi:10.1007/s10853-019-03438-3 · Cited by 78
Liu, W., Zheng, Y., Wang, Z., Wang, Z., Yang, J., Chen, M., Qi, M., Ur Rehman, S., Shum, P. P., Zhu, L., et al. (2021) · Advanced Materials Interfaces · doi:10.1002/admi.202001978 · Cited by 77
Relative Humidity Sensors Based on an Environment-Sensitive Fluorophore in Hydrogel Films
Tellis, J. C., Strulson, C. A., Myers, M. M., & Kneas, K. A. (2011) · Analytical Chemistry · doi:10.1021/ac102616w · Cited by 75 · cited 1×
“Tellis et al. [271] developed a fluorescence-based relative humidity measurement scheme using environmentally sensitive fluorophores embedded in hydrogels.”
Chen, Y., Xu, P., Li, X., Ren, Y., & Deng, Y. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.180 · Cited by 75
Choi, M. M. F., & Tse, O. L. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00614-x · Cited by 74 · cited 1×
“For example, in museums and libraries, humidity monitoring and control facilitates the preservation of artifacts, paintings, sculptures or books, while in industrial applications such as semiconductor, textile and food production, humidity monitoring is also required [268, 269].”
BackgroundChoi, S., Choi, H.-J., Koo, W., Huh, D., Lee, H., & Kim, I. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11317 · Cited by 73
Lee, J.-H., Kim, J.-H., Kim, J.-Y., Mirzaei, A., Kim, H. W., & Kim, S. S. (2019) · Sensors · doi:10.3390/s19194276 · Cited by 73
Synergistic Thermoresponsive Optical Properties of a Composite Self-Healing Hydrogel
Owusu‐Nkwantabisah, S., Gillmor, J. R., Switalski, S. C., Mis, M. R., Bennett, G., Moody, R. E., Antalek, B. J., Gutierrez, R., & Slater, G. (2017) · Macromolecules · doi:10.1021/acs.macromol.7b00355 · Cited by 72 · cited 1×
“…be achieved by the hydrophobic part of hydrogels by the autonomous loading between hydrophobic structural domains/conjugation, metal–ligand coordination by the reversible chelation between ligands and metal atoms, and host–guest by combining interactions with different binding affinities [179–184].”
BackgroundDing, Q., Zhou, Z., Wang, H., Wu, Z., Tao, K., Yang, B., Xie, X., Fu, J., & Wu, J. (2023) · SmartMat · doi:10.1002/smm2.1141 · Cited by 72 · cited 3×
“[67] used a facile one-pot polymerization method to prepare PVA/cellulose nanofibril (CNF)–glycerol (Gly) DN organohydrogel with significantly improved water storage and freezing resistance (Fig.”
BackgroundMethodSelf-citationAziz, F., Sayyad, M. H., Sulaiman, K., et al. (2011) · Measurement Science and Technology · doi:10.1088/0957-0233/23/1/014001 · Cited by 70
Patrick Williams, W., Quinn, P. J., Tsonev, L. I., & Koynova, R. D. (1991) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(91)90383-j · Cited by 69
Room temperature ammonia gas sensor based on ionic conductive biomass hydrogels
Liu, L., Fei, T., Guan, X., Lin, X., Zhao, H., & Zhang, T. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128318 · Cited by 69 · cited 1×
“[71] prepared a highly sensitive, nontoxic, and environmentally friendly electrical NH3 hydrogel sensor under humid environment at 25 °C using biomass hydrogel GA and poly-L-glutamate (PGA) as sensitive composite materials.”
MethodDuy, L. T., Trung, T. Q., Hanif, A., Siddiqui, S., Roh, E., Lee, W., & Lee, N.-E. (2017) · 2D Materials · doi:10.1088/2053-1583/aa6783 · Cited by 68
An adaptive ionic skin with multiple stimulus responses and moist-electric generation ability
Pan, X., Wang, Q., Guo, R., Cao, S., Wu, H., Ouyang, X., Huang, F., Gao, H., Huang, L., Zhang, F., et al. (2020) · Journal of Materials Chemistry A · doi:10.1039/c9ta13407g · Cited by 66
Highly Stretchable and Permeable Conductors Based on Shrinkable Electrospun Fiber Mats
Li, Q., Ding, C., Yuan, W., Xie, R., Zhou, X., Zhao, Y., Yu, M., Yang, Z., Sun, J., Tian, Q., et al. (2021) · Advanced Fiber Materials · doi:10.1007/s42765-021-00079-7 · Cited by 66
Wei, Y., Wang, H., Ding, Q., Wu, Z., Zhang, H., Tao, K., Xie, X., & Wu, J. (2022) · Materials Horizons · doi:10.1039/d2mh00284a · Cited by 66 · cited 3×
“Recent studies have validated the sensing process of hydrogel gas sensors [67, 69, 150, 206].”
BackgroundMethodSelf-citationTissue oxygen tension monitoring of organ perfusion: rationale, methodologies, and literature review
De Santis, V., & Singer, M. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev162 · Cited by 64 · cited 1×
“At this time, monitoring the oxygen partial pressure of the skin can reflect the actual oxygen supply to the tissue cells, thus directly reflecting the microcirculation of the skin and indirectly reflecting the macrovascular condition [231, 232].”
BackgroundChoi, J., Kim, J.-H., Oh, J., & Nam, J. (2019) · Nanoscale · doi:10.1039/c9nr07439b · Cited by 60
Liu, L., Fei, T., Guan, X., Zhao, H., & Zhang, T. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113459 · Cited by 60 · cited 1×
“1007/s40820-023-01109-2 © The authors Zhang and her team [76] used thiol-ene photochemistry to encapsulate citric acid (CA) into crosslinked polyethylene glycol diacrylate (PEGDA) hydrogels to prepare a highly sensitive and selective CA/PEGDA hydrogel-based NH3 gas sensor working at high humidity (80% RH).”
BackgroundFu, Y., He, H., Liu, Y., Wang, Q., Xing, L., & Xue, X. (2017) · Journal of Materials Chemistry C · doi:10.1039/c6tc04272d · Cited by 58 · cited 1×
“They could be attached to the surface of the human body to measure various body parameters or environmental parameters, expanding people’s knowledge of themselves and their environment, acting as a human second skin [278–283].”
BackgroundMatsugami, M., Takamuku, T., Otomo, T., & Yamaguchi, T. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp061456r · Cited by 56
Liu, J., Wang, H., Ou, R., Yi, X., Liu, T., Liu, Z., & Wang, Q. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.130722 · Cited by 56 · cited 1×
“…with enhanced mechanical deformability and controlled structure and degradation, such as polyethylene glycol (PEG), polyvinyl alcohol (PVA), poly(2-hydroxyethyl methacrylate) (PHEMA) and polyacrylamide (PAM), can be used in sensors, actuators, soft robots, and wastewater treatment [95–101].”
BackgroundSelf-citationKim, H. D., Heo, J., Hwang, Y., Kwak, S.-Y., Park, O. K., Kim, H., Varghese, S., & Hwang, N. S. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2014.0233 · Cited by 55 · cited 1×
“…and the hydroxyl groups in it combine with surrounding free water molecules through hydrogen bonding, which effectively inhibits the formation of hydrogen bonds between water molecules at sub-zero temperatures, and directly preventing ice crystal formation and lowering the freezing point [211–213].”
BackgroundBag, A., Moon, D.-B., Park, K.-H., Cho, C.-Y., & Lee, N.-E. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.126684 · Cited by 55
Maughan, R. (2009) · Surgery (Oxford) · doi:10.1016/j.mpsur.2008.12.002 · Cited by 55
Low-Temperature Ionic Conductivity Enhanced by Disrupted Ice Formation in Polyampholyte Hydrogels
Li, X., Charaya, H., Bernard, G. M., Elliott, J. A. W., Michaelis, V. K., Lee, B., & Chung, H. (2018) · Macromolecules · doi:10.1021/acs.macromol.7b02498 · Cited by 54
Liebisch, F., Weltin, A., Marzioch, J., Urban, G. A., & Kieninger, J. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128652 · Cited by 53 · cited 1×
“Liebisch et al. [233] prepared a Clark-type oxygen micro-sensors that can operate in an aqueous environment.”
BackgroundDurable and Flexible Bio-assembled RGO-BC/BC Bilayer Electrodes for Pressure Sensing
Guan, F., Han, Z., Jin, M., Wu, Z., Chen, Y., Chen, S., & Wang, H. (2021) · Advanced Fiber Materials · doi:10.1007/s42765-021-00066-y · Cited by 49
Self-citationConducting hydrogels for edible electrodes
Keller, A., Pham, J., Warren, H., & Panhuis, M. I. H. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01247k · Cited by 47 · cited 1×
“3d) [127, 146, 147].”
Analysis of hazardous chemicals by “stand alone” drift tube ion mobility spectrometry: a review
Armenta, S., Esteve-Turrillas, F. A., & Alcalà, M. (2020) · Analytical Methods · doi:10.1039/c9ay02268f · Cited by 45 · cited 1×
“…coupled with MS (GC–MS), surface-enhanced Raman spectroscopy (SERS), nuclear quadrupole resonance (NQR) and energy dispersive X-ray diffraction (EDXRD), although with high selectivity, but bulky, expensive, not conducive to set in public places for the real-time monitoring of explosives [241–248].”
BackgroundKim, J., Hong, S., Lee, J.-S., et al. (2009) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2009.5068676 · Cited by 44 · cited 1×
“It has applications in meteor-ology, hydrology, medicine, biology, agriculture, forestry, and production and storage of various products [261–266].”
BackgroundFast Optical Humidity Sensor Based on Hydrogel Thin Film Expansion for Harsh Environment
Buchberger, A., Peterka, S., Coclite, A. M., & Bergmann, A. (2019) · Sensors · doi:10.3390/s19050999 · Cited by 43 · cited 1×
“In addition, hydrogel films of PHEMA on the order of several hundred nanometers were prepared by Buch-berger et al. [272] using chemical vapor deposition.”
MethodWu, Z., Ding, Q., Li, Z., Zhou, Z., Luo, L., Tao, K., Xie, X., & Wu, J. (2022) · Science China Materials · doi:10.1007/s40843-021-2022-1 · Cited by 42 · cited 2×
“Wu et al. [152] added lithium bromide (LiBr) to PAM/Carr hydrogels using the immersion method, which significantly inhibited dehydration and freezing (Fig.”
MethodSelf-citationWang, Y., Chen, Q., Chen, M., Guan, Y., & Zhang, Y. (2019) · Polymer Chemistry · doi:10.1039/c9py00670b · Cited by 41
Crespy, C., Duvauchelle, P., Kaftandjian, V., et al. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.08.023 · Cited by 37
High Performance CuO Nanorectangles-Based Room Temperature Flexible NH3Sensor
Sakthivel, B., Manjakkal, L., & Gopalakrishnan, N. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2749334 · Cited by 34
Xu, L., Wang, R., Xiao, Q., Zhang, D., & Liu, Y. (2011) · Chinese Physics Letters · doi:10.1088/0256-307x/28/7/070702 · Cited by 32
Highly Sensitive Diffraction Grating of Hydrogels as Sensors for Carbon Dioxide Detection
Xu, L., Tang, B., Wu, B., et al. (2021) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.1c00211 · Cited by 32 · cited 1×
“In the similar vein, Li et al. [237] developed a gas sensor for detecting dissolved CO 2 concentration.”
BackgroundLin, Y., Wu, Z., Li, C., Ding, Q., Tao, K., Zhai, K., Chen, M., Zilberman, M., Xie, X., & Wu, J. (2022) · EcoMat · doi:10.1002/eom2.12220 · Cited by 30 · cited 1×
“Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications, such as NO 2 , NH 3 , CO 2 , and O 2 [67–75].”
BackgroundSelf-citationNuclear Quadrupole Resonance for Explosive Detection
Itozaki, H. (2009) · Springer eBooks · doi:10.1007/978-1-84882-346-4_9 · Cited by 26
Highly Sensitive Humidity Sensor Using Pd/Porous GaAs Schottky Contact
Salehi, A., Nikfarjam, A., & Kalantari, D. J. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.881371 · Cited by 26
Hydrogel Based-Electrochemical Gas Sensor for Explosive Material Detection
Puttasakul, T., Pintavirooj, C., Sangma, C., & Sukjee, W. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2922170 · Cited by 25
Dong, C., Jiang, M., Tao, Y., Shen, Y., Lu, Y., Yuan, Y., & Wang, Y. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.10.175 · Cited by 24 · cited 1×
“Moreover, flammable and explosive gases, such as H 2 and CH 4 , pose a direct threat to the safety of human life and property [12–17].”
BackgroundThe Israel Naval Medical Institute, H., Arieli, R., & Eliachar Research Laboratory, W. G. M. C. (2019) · Diving and Hyperbaric Medicine Journal · doi:10.28920/dhm49.3.154-160 · Cited by 24 · cited 1×
“When people are exposed to high partial pressures of oxygen (PO 2 ), the central nervous system and the pulmonary system will suffer damage, some of which is even irreversible [226–228].”
BackgroundMechanism of Surface Wrinkle Modulation for a Stiff Film on Compliant Substrate
Liu, Y., Li, M., Liu, J., & Chen, X. (2017) · Journal of Applied Mechanics · doi:10.1115/1.4036256 · Cited by 23
Dehbari, N., Tavakoli, J., Zhao, J., & Tang, Y. (2016) · Journal of Applied Polymer Science · doi:10.1002/app.44548 · Cited by 21 · cited 1×
“Since 1954, when Wichterle and Lim first synthesized hydrogel [54], it has been widely used in various fields, including food preparation, bioengineering, agriculture, healthcare, and biosensors [55–63].”
MethodA CO 2 -responsive hydrogel film for optical sensing of dissolved CO 2
Wang, R., Zhang, M., Guan, Y., Chen, M., & Zhang, Y. (2019) · Soft Matter · doi:10.1039/c9sm00958b · Cited by 21 · cited 1×
“[73] prepared hydrogel membranes from branched polyethyleneimine (BPEI) and partially oxidized dextran (PO-DEX) by in situ Schiff base reaction to achieve rapid, real-time, and continuous monitoring of dissolved CO2.”
BackgroundHarabin, A. L., Survanshi, S. S., & Homer, L. D. (1995) · Toxicology and Applied Pharmacology · doi:10.1006/taap.1995.1082 · Cited by 18
Effectiveness of Combined Laser and Gas Chromatographic Remote Detection of Traces of Explosives
Балдин, М. Н., Bobrovnikov, S. M., Vorozhtsov, A., et al. (2019) · Atmospheric and Oceanic Optics · doi:10.1134/s1024856019020039 · Cited by 17
Sensitively humidity-driven actuator and sensor derived from natural skin system
Wang, Y., Duan, R., Tong, Z., Wang, B., Zhang, Z., & Li, Y. (2022) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2022.132388 · Cited by 14
Chajistamatiou, A. S., & Bakeas, E. B. (2018) · Talanta · doi:10.1016/j.talanta.2018.11.097 · Cited by 13 · cited 1×
“…coupled with MS (GC–MS), surface-enhanced Raman spectroscopy (SERS), nuclear quadrupole resonance (NQR) and energy dispersive X-ray diffraction (EDXRD), although with high selectivity, but bulky, expensive, not conducive to set in public places for the real-time monitoring of explosives [241–248].”
BackgroundFibre Optic Sensors for Humidity Monitoring
Moreno‐Bondi, M. C., Orellana, G., & Bedoya, M. (2004) · Springer series on chemical sensors and biosensors · doi:10.1007/978-3-662-09111-1_11 · Cited by 9 · cited 1×
“For example, in museums and libraries, humidity monitoring and control facilitates the preservation of artifacts, paintings, sculptures or books, while in industrial applications such as semiconductor, textile and food production, humidity monitoring is also required [268, 269].”
BackgroundArieli, R., Truman, M., & Abramovich, A. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0843-2 · Cited by 5 · cited 1×
“When people are exposed to high partial pressures of oxygen (PO 2 ), the central nervous system and the pulmonary system will suffer damage, some of which is even irreversible [226–228].”
BackgroundBreathing systems in aerospace
Ernsting, J. (1999) · doi:10.1049/ic:19990341 · Cited by 5 · cited 1×
“However, sometimes a high oxygen concentration environment is still desirable, such as anesthesia machines and hyperbaric chambers in hospitals [224, 229].”
Background
Cited by
Sun, T., Feng, B., Huo, J., Xiao, Y., Wang, W., Peng, J., Li, Z., Du, C., Wang, W., Zou, G., et al. (2024) · Nano-Micro Letters · doi:10.1007/s40820-023-01235-x · Cited by 384
Smart Gas Sensors: Recent Developments and Future Prospective
Zong, B., Wu, S., Yang, Y., Li, Q., Tao, T., & Mao, S. (2025) · Nano-Micro Letters · doi:10.1007/s40820-024-01543-w · Cited by 282
Mei, H., Peng, J., Wang, T., Zhou, T., Zhao, H., Zhang, T., & Yang, Z. (2024) · Nano-Micro Letters · doi:10.1007/s40820-024-01489-z · Cited by 177
The Challenges and Opportunities for TiO2 Nanostructures in Gas Sensing
Zhao, J., Wang, H., Cai, Y., Zhao, J., Gao, Z., & Song, Y.-Y. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00137 · Cited by 164
Self-citationAdvances in ionic conductive hydrogels for skin sensor applications
Mo, F., Lin, Y., Liu, Y., Zhou, P., Yang, J., Ji, Z., & Wang, Y. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.100989 · Cited by 169
Metadata
- Authors
- Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J.
- Affiliations
- Sun Yat-sen University (CN)
- Corresponding author
- Wu, Jin
- Venue
- Nano-Micro Letters
- Published
- 2023-05-24
- Volume
- 15
- Issue
- 1
- Pages
- 136-136
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- PMC
- PMC10209388
- OpenAlex
- W4378070105
- Cited by
- 236
- References
- 289
- Citations by year
- 2026: 55 · 2025: 97 · 2024: 68 · 2023: 16
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nano-Micro Letters (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Shanghai Jiao Tong University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- hydrogel-based sensors, wearable sensors, gas sensors, humidity sensor, vapor sensing, functionalized hydrogels, personal health monitoring, self-healing hydrogels, stretchable sensors, home health care
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.