MCML—Monte Carlo modeling of light transport in multi-layered tissues
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, simulation techniques such as the Monte Carlo method [18], and exact electromagnetic solvers are employed to model the optical/radiative properties of disordered coatings.However, these simulation techniques do not present a clear picture linking the microscopic properties of the particles, such as the scattering and absorption coefficients, to the macroscopic optical properties of”
From Semi-analytical technique for the design of disordered coatings with tailored optical properties (2023) · cites this paper as [18]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light
Born, M., Wolf, E., & Hecht, E. (2000) · Physics Today · doi:10.1063/1.1325200 · Cited by 4,078
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“10 (1983) 824-830. [Z] S.& Prahl, M. Keijzer, St. Jacques and A.J. Welch, A Monte Carlo model of light propagation in tissue, Proc. SPIE IS 5 (1989) 102-111.”
BackgroundOptical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
Optical-Thermal Response of Laser-Irradiated Tissue
(1995) · Springer eBooks · doi:10.1007/978-1-4757-6092-7 · Cited by 705
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
A Monte Carlo model of light propagation in tissue
Prahl, S. A. (1989) · SPIE Proceedings · doi:10.1117/12.2283590 · Cited by 616
Flock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Cited by
Nondestructive measurement of fruit and vegetable quality by means of NIR spectroscopy: A review
Nicolaï, B. M., Beullens, K., Bobelyn, E., Peirs, A., Saeys, W., Theron, K. I., & Lammertyn, J. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.06.024 · Cited by 2,252
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
“By using diffusion approximations and finite-element or Monte-Carlobased computational methods [12,13,16,73–76], we can estimate the sensitivity profile for each source–detector pair on the basis of the optical properties of the tissue as shown in Fig 1(a).”
BackgroundMethodUnderwater Optical Wireless Communication
Kaushal, H., & Kaddoum, G. (2016) · IEEE Access · doi:10.1109/access.2016.2552538 · Cited by 1,428
A Survey of Underwater Optical Wireless Communications
Zeng, Z., Fu, S., Zhang, H., Dong, Y., & Cheng, J. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2618841 · Cited by 1,287
“It is a probabilistic method to mimic the loss of underwater light propagation by sending and tracking large number of photons [70], [71].”
MethodMechanisms and applications of the anti-inflammatory effects of photobiomodulation
R Hamblin, M., 1 Wellman Center for Photomedicine, M. G. H., 2 Department of Dermatology, H. M. S., & 3 Harvard-MIT Division of Health Sciences and Technology, C. (2017) · AIMS Biophysics · doi:10.3934/biophy.2017.3.337 · Cited by 1,265
Hierarchical-morphology metafabric for scalable passive daytime radiative cooling
Zeng, S., Pian, S., Su, M., Wang, Z., Wu, M., Liu, X., Chen, M., Xiang, Y., Wu, J., Zhang, M., et al. (2021) · Science · doi:10.1126/science.abi5484 · Cited by 1,135
The physics, biophysics and technology of photodynamic therapy
Wilson, B. C., & Patterson, M. S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/9/r01 · Cited by 1,006
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Jan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Tissue polarimetry: concepts, challenges, applications, and outlook
Ghosh, N. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3652896 · Cited by 740
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Quantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Underwater optical wireless communications, networking, and localization: A survey
Saeed, N., Celik, A., Al-Naffouri, T. Y., & Alouini, M.-S. (2019) · Ad Hoc Networks · doi:10.1016/j.adhoc.2019.101935 · Cited by 560
Time-reversed ultrasonically encoded optical focusing into scattering media
Xu, X., Liu, H., & Wang, L. V. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.306 · Cited by 518
Self-citationLaser optoacoustic imaging system for detection of breast cancer
Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3086616 · Cited by 493
In vivo imaging of light-emitting probes
Rice, B. W., Cable, M. D., & Nelson, M. B. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1413210 · Cited by 493
Monte-Carlo-Based Channel Characterization for Underwater Optical Communication Systems
Gabriel, C., Khalighi, M.-A., Bourennane, S., Léon, P., & Rigaud, V. (2013) · Journal of Optical Communications and Networking · doi:10.1364/jocn.5.000001 · Cited by 493
Shakeel Ahmad, M., Pandey, A. K., & Abd Rahim, N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.129 · Cited by 480
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
Time domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Mallidi, S., Larson, T., Tam, J., Joshi, P. P., Karpiouk, A., Sokolov, K., & Emelianov, S. (2009) · Nano Letters · doi:10.1021/nl802929u · Cited by 446
Microfluidics‐Enabled Multimaterial Maskless Stereolithographic Bioprinting
Miri, A. K., Nieto, D., Iglesias, L., Goodarzi Hosseinabadi, H., Maharjan, S., Ruiz‐Esparza, G. U., Khoshakhlagh, P., Manbachi, A., Dokmeci, M. R., Chen, S., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800242 · Cited by 431
Two-photon microscopy in brain tissue: parameters influencing the imaging depth
Oheim, M., Beaurepaire, E., Chaigneau, E., Mertz, J., & Charpak, S. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00438-1 · Cited by 425
Bhutani, V. K., Gourley, G. R., Adler, S., Kreamer, B., Dalin, C., & Johnson, L. H. (2000) · Pediatrics · doi:10.1542/peds.106.2.e17 · Cited by 417
Wilson, R. H., Nadeau, K. P., Jaworski, F. B., Tromberg, B. J., & Durkin, A. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.3.030901 · Cited by 415
Meglinski, I. V., & Matcher, S. J. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/4/312 · Cited by 408
“Following earlier work aimed at computational modelling of the skin (Keijzer et al 1989, Prahl et al 1989, Yaroslavsky and Tuchin 1992, Tuchin 1992, Wang et al 1995, Svaasand et al 1995, Verkruysse et al 1999, Meglinsky and Matcher 2001a, Meglinskii and Matcher 2001b) we have simulated skin as a…”
MethodInfluentialAlerstam, E., Svensson, T., & Andersson-Engels, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041496 · Cited by 407
Perfecting and extending the near-infrared imaging window
Feng, Z., Tang, T., Wu, T., Yu, X., Zhang, Y., Wang, M., Zheng, J., Ying, Y., Chen, S., Zhou, J., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00628-0 · Cited by 394
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates
Fang, Q. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000165 · Cited by 384
Modeling the Spatiotemporal Dynamics of Light and Heat Propagation for In Vivo Optogenetics
Stujenske, J. M., Spellman, T., & Gordon, J. A. (2015) · Cell Reports · doi:10.1016/j.celrep.2015.06.036 · Cited by 383
Tutorial on diffuse light transport
Jacques, S. L., & Pogue, B. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2967535 · Cited by 354
Self-citationReview of Monte Carlo modeling of light transport in tissues
Zhu, C., & Liu, Q. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.050902 · Cited by 352
Ma, Y., Shaik, M. A., Kim, S. H., Kozberg, M. G., Thibodeaux, D. N., Zhao, H. T., Yu, H., & Hillman, E. M. C. (2016) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2015.0360 · Cited by 335
Impulse Response Modeling for Underwater Wireless Optical Communication Links
Tang, S., Dong, Y., & Zhang, X. (2014) · IEEE Transactions on Communications · doi:10.1109/tcomm.2013.120713.130199 · Cited by 332
Palmer, G. M., & Ramanujam, N. (2006) · Applied Optics · doi:10.1364/ao.45.001062 · Cited by 323
Noninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 294
Ding, H., Lu, J. Q., Wooden, W. A., Kragel, P. J., & Hu, X.-H. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/6/008 · Cited by 291
Wang, F., Ren, F., Ma, Z., Qu, L., Gourgues, R., Xu, C., Baghdasaryan, A., Li, J., Zadeh, I. E., Los, J. W. N., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01130-3 · Cited by 283
Three Monte Carlo programs of polarized light transport into scattering media: part II
Ramella-Roman, J. C., Prahl, S. A., & Jacques, S. L. (2005) · Optics Express · doi:10.1364/opex.13.010392 · Cited by 280
Self-citationPark, Y., Franz, C. K., Ryu, H., Luan, H., Cotton, K. Y., Kim, J. U., Chung, T. S., Zhao, S., Vazquez-Guardado, A., Yang, D. S., et al. (2021) · Science Advances · doi:10.1126/sciadv.abf9153 · Cited by 280
Robinson, D. J., de Bruijn, H. S., van der Veen, N., Stringer, M. R., Brown, S. B., & Star, W. M. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05177.x · Cited by 269
Ghosh, N., Wood, M. F. G., & Vitkin, I. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2960934 · Cited by 265
Nadiarnykh, O., LaComb, R. B., Brewer, M. A., & Campagnola, P. J. (2010) · BMC Cancer · doi:10.1186/1471-2407-10-94 · Cited by 264
Strangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 262
Haeussinger, F. B., Heinzel, S., Hahn, T., Schecklmann, M., Ehlis, A.-C., & Fallgatter, A. J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026377 · Cited by 261
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
Tzoumas, S., Nunes, A., Olefir, I., Stangl, S., Symvoulidis, P., Glasl, S., Bayer, C., Multhoff, G., & Ntziachristos, V. (2016) · Nature Communications · doi:10.1038/ncomms12121 · Cited by 248
Recent advances in wavefront shaping techniques for biomedical applications
Yu, H., Park, J., Lee, K., Yoon, J., Kim, K., Lee, S., & Park, Y. (2015) · Current Applied Physics · doi:10.1016/j.cap.2015.02.015 · Cited by 248
“Until recently, it had been understood that multiple light scattering is a random process with an extremely high degree of freedom; thus, light transport in tissues has been considered using stochastic ensemble approaches such as the photon diffusion equation [23] and Monte Carlo simulations [24].”
BackgroundThe role of photodynamic therapy (PDT) physics
Zhu, T. C., & Finlay, J. C. (2008) · Medical Physics · doi:10.1118/1.2937440 · Cited by 244
Light-sheet microscopy in the near-infrared II window
Wang, F., Wan, H., Ma, Z., Zhong, Y., Sun, Q., Tian, Y., Qu, L., Du, H., Zhang, M., Li, L., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0398-7 · Cited by 237
Measurement of optical properties of fruits and vegetables: A review
Lu, R., Van Beers, R., Saeys, W., Li, C., & Cen, H. (2020) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2019.111003 · Cited by 220
“Classic MC algorithms, such as the MC code for multi-layered media, allow to simulate light propagation in multi-layered, semi-infinite slabs (Wang et al., 1995).”
MethodChromophore concentrations, absorption and scattering properties of human skin in-vivo
Tseng, S.-H., Bargo, P., Durkin, A., & Kollias, N. (2009) · Optics Express · doi:10.1364/oe.17.014599 · Cited by 217
Anisotropy in the absorption and scattering spectra of chicken breast tissue
Marquez, G., Wang, L. V., Lin, S.-P., Schwartz, J. A., & Thomsen, S. L. (1998) · Applied Optics · doi:10.1364/ao.37.000798 · Cited by 215
Self-citationMonte Carlo simulations of the diffuse backscattering Mueller matrix for highly scattering media
Bartel, S., & Hielscher, A. H. (2000) · Applied Optics · doi:10.1364/ao.39.001580 · Cited by 214
“20–22 we concentrate on the adaptation of this code to consider polarized light.”
BackgroundGutruf, P., Krishnamurthi, V., Vázquez-Guardado, A., Xie, Z., Banks, A., Su, C.-J., Xu, Y., Haney, C. R., Waters, E. A., Kandela, I., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0175-0 · Cited by 210
Abdelnour, A. F., & Huppert, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.033 · Cited by 208
“This optical window allows light to penetrate deep enough to sample through the outer 1.5–2 cm of skin and skull and reach the outer approximately 5–10 mm of brain tissue (Wang et al., 1995; Fukui et al., 2003), which provides sensitivity to hemoglobin changes in the outermost cortex of the brain.”
BackgroundInfluentialLutzweiler, C., & Razansky, D. (2013) · Sensors · doi:10.3390/s130607345 · Cited by 203
“One frequently applied approach to model the transport of diffuse light is the Monte Carlo (MC) method, which simulates a random walk of a great number of photons through the scattering tissue [127–129].”
MethodZonios, G., & Dimou, A. (2006) · Optics Express · doi:10.1364/oe.14.008661 · Cited by 196
Blood analysis by Raman spectroscopy
Enejder, A. M. K., Koo, T.-W., Oh, J., Hunter, M., Sasic, S., Feld, M. S., & Horowitz, G. L. (2002) · Optics Letters · doi:10.1364/ol.27.002004 · Cited by 184
Determination of the optical properties of turbid media from a single Monte Carlo simulation
Kienle, A., & Patterson, M. S. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/10/026 · Cited by 183
Computer simulation of the skin reflectance spectra
Meglinski, I. V., & Matcher, S. J. (2003) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(02)00099-8 · Cited by 179
Physical model for the spectroscopic analysis of cortical intrinsic optical signals
Kohl, M., Lindauer, U., Royl, G., Kühl, M., Gold, L., Villringer, A., & Dirnagl, U. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/12/317 · Cited by 176
Estimating chromophore distributions from multiwavelength photoacoustic images
Cox, B. T., Arridge, S. R., & Beard, P. C. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.000443 · Cited by 174
Next-generation acceleration and code optimization for light transport in turbid media using GPUs
Alerstam, E., Yip Lo, W. C., Han, T. D., Rose, J., Andersson-Engels, S., & Lilge, L. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000658 · Cited by 172
Optical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
“The Monte Carlo (MC) method has been frequently used for modeling photon-tissue interactions in the brain.(202,203) Because diffusion-based models(204,205) can be inaccurate in the presence of cerebrospinal fluid (CSF),(206) MC simulations provide a more accurate alternative to analytical models in the brain.”
MethodChannel modeling for underwater optical communication
Gabriel, C., Khalighi, M.-A., Bourennane, S., Leon, P., & Rigaud, V. (2011) · 2011 IEEE GLOBECOM Workshops (GC Wkshps) · doi:10.1109/glocomw.2011.6162571 · Cited by 170
“To generate δ randomly, we consider the random variable (RV) χδ with a uniform distribution U [0, 1] and use δ = − log(χδ)/c [17].”
MethodHigh-density diffuse optical tomography for imaging human brain function
Wheelock, M. D., Culver, J. P., & Eggebrecht, A. T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086809 · Cited by 168
A dual-layer structure with record-high solar reflectance for daytime radiative cooling
Yang, P., Chen, C., & Zhang, Z. M. (2018) · Solar Energy · doi:10.1016/j.solener.2018.04.031 · Cited by 167
LaComb, R., Nadiarnykh, O., Townsend, S. S., & Campagnola, P. J. (2008) · Optics Communications · doi:10.1016/j.optcom.2007.10.040 · Cited by 166
Online object oriented Monte Carlo computational tool for the needs of biomedical optics
Doronin, A., & Meglinski, I. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002461 · Cited by 162
Jacques, S. L. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05161.x · Cited by 161
Self-citationWu, J., You, L., Lan, L., Lee, H. J., Chaudhry, S. T., Li, R., Cheng, J., & Mei, J. (2017) · Advanced Materials · doi:10.1002/adma.201703403 · Cited by 160
Wang, R. K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/13/307 · Cited by 159
Chen, A. I., Balter, M. L., Chen, M. I., Gross, D., Alam, S. K., Maguire, T. J., & Yarmush, M. L. (2016) · Medical Physics · doi:10.1118/1.4951729 · Cited by 158
Spatial frequency domain imaging in 2019: principles, applications, and perspectives
Gioux, S., Mazhar, A., & Cuccia, D. J. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.7.071613 · Cited by 158
Shimojo, Y., Nishimura, T., Hazama, H., Ozawa, T., & Awazu, K. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.4.045002 · Cited by 132
“were then calculated with the prepared sets of μa and μ 0 s and the sample geometry using a Monte Carlo code named MCML developed by Wang et al.(23) The calculated values of Rd;cal and T t;cal were next compared with the measured values of Rd;exp.”
ResultA coaxial optrode as multifunction write-read probe for optogenetic studies in non-human primates
Ozden, I., Wang, J., Lu, Y., May, T., Lee, J., Goo, W., O'Shea, D. J., Kalanithi, P., Diester, I., Diagne, M., et al. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.06.011 · Cited by 97
Chatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
Ajmal, Boonya-Ananta, T., Rodriguez, A. J., Du Le, V. N., & Ramella-Roman, J. C. (2021) · Biomedical Optics Express · doi:10.1364/boe.439893 · Cited by 79
A shape-memory and spiral light-emitting device for precise multisite stimulation of nerve bundles
Zheng, H., Zhang, Z., Jiang, S., Yan, B., Shi, X., Xie, Y., Huang, X., Yu, Z., Liu, H., Weng, S., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10418-3 · Cited by 58
Gender variations in the optical properties of skin in murine animal models
Calabro, K., Curtis, A., Galarneau, J.-R., Krucker, T., & Bigio, I. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3525565 · Cited by 58
High Density, Double-Sided, Flexible Optoelectronic Neural Probes With Embedded μLEDs
Reddy, J. W., Kimukin, I., Stewart, L. T., Ahmed, Z., Barth, A. L., Towe, E., & Chamanzar, M. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00745 · Cited by 55
Mignon, C., Tobin, D. J., Zeitouny, M., & Uzunbajakava, N. E. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.000852 · Cited by 43
“They include the solutions of the radiative transfer equation under strict approximation, the analytical application of the random walk theory to biological tissue [22], and the Monte Carlo methods [23].”
Skin colour affects the accuracy of medical oxygen sensors
Keller, M. D., Harrison-Smith, B., Patil, C., & Arefin, M. S. (2022) · Nature · doi:10.1038/d41586-022-03161-1 · Cited by 38
Noninvasive optical inhibition with a red-shifted microbial rhodopsin
Chuong, A. S., Miri, M. L., Busskamp, V., Matthews, G. A. C., Acker, L. C., Sørensen, A. T., Young, A., Klapoetke, N. C., Henninger, M. A., Kodandaramaiah, S. B., et al. (2014) · Nature Neuroscience · doi:10.1038/nn.3752 · Cited by 33
McHardy, C., Horneber, T., & Rauh, C. (2016) · Optics Express · doi:10.1364/oe.24.016999 · Cited by 24
Phan, T., Rowland, R. A., Ponticorvo, A., Le, B. C., Sharif, S. A., Kennedy, G. T., Wilson, R. H., & Durkin, A. J. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.3.036002 · Cited by 18
Semi-analytical technique for the design of disordered coatings with tailored optical properties
Rishi Mishra, B., Jo Varghese, N., & Sasihithlu, K. (2023) · Optics Express · doi:10.1364/oe.484308 · Cited by 15
Metadata
- Authors
- Wang, L., Jacques, S. L., & Zheng, L.
- Venue
- Computer Methods and Programs in Biomedicine
- Publisher
- Elsevier BV
- Published
- 1995-07
- Volume
- 47
- Issue
- 2
- Pages
- 131-146
- ISSN
- 0169-2607 (ISSN-L)
- OpenAlex
- W2013492930
- Cited by
- 3,324
- References
- 18
- FWCI
- 11.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.