The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes
Abstract
The stability of the interface between neural tissue and chronically implanted microelectrodes is very important for obtaining reliable control signals for neuroprosthetic devices. Stability is also crucial for chronic microstimulation of the cerebral cortex. However, changes of the electrode-tissue interface can be caused by a variety of mechanisms. In the present study, intracortical microelectrode arrays were implanted into the pericruciate gyrus of cats and neural activities were recorded on a regular basis for several months. An algorithm based on cluster analysis and interspike interval analysis was developed to sort the extracellular action potentials into single units. We tracked these units based on their waveform and their response to somatic stimulation or stereotypical movements by the cats. Our results indicate that, after implantation, the electrode-tissue interface may change from day-to-day over the first 1-2 weeks, week-to-week for 1-2 months, and become quite stable thereafter. A stability index is proposed to quantify the stability of the electrode-tissue interface. The reasons for the pattern of changes are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Everitt, B. J., Landau, S., & Leese, M. (1974) · Cited by 9,358
Cluster Analysis for Applications
(1973) · Elsevier eBooks · doi:10.1016/c2013-0-06161-0 · Cited by 5,080
Axonal sprouting accompanies functional reorganization in adult cat striate cortex
Darian-Smith, C., & Gilbert, C. D. (1994) · Nature · doi:10.1038/368737a0 · Cited by 599
Fee, M. S., Mitra, P. P., & Kleinfeld, D. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00050-7 · Cited by 357
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299
Long-term implants of Parylene-C coated microelectrodes
Schmidt, E. M., Mcintosh, J. S., & Bak, M. J. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441836 · Cited by 234
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.634645 · Cited by 130
Self-citationLong-term chronic recording from cortical neurons
Schmidt, E. M., Bak, M. J., & McIntosh, J. S. (1976) · Experimental Neurology · doi:10.1016/0014-4886(76)90220-x · Cited by 127
Schmidt, E. M. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363437 · Cited by 126
Visual prostheses based on direct interfaces with the visual system.
Hambrecht, F. T. (1995) · PubMed · Cited by 47
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Brain-computer interfaces for communication and control
McFarland, D. J., & Wolpaw, J. R. (2011) · Communications of the ACM · doi:10.1145/1941487.1941506 · Cited by 519
Encyclopedia of Applied Electrochemistry
(2014) · Springer eBooks · doi:10.1007/978-1-4419-6996-5 · Cited by 482
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
Using a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90989.2008 · Cited by 420
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“Despite the potential that penetrating intracortical microelectrodes have shown, widespread implementation is impeded by the inability to consistently record high quality neural signals over clinically relevant time frames [14–17].”
BackgroundKipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“between the electrode and its nearest target neurons [74], and produces an inhibitory environment for neurite extension, thus guiding regenerating neural processes away from the electrodes [72,81].”
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 341
Zhong, Y., & Bellamkonda, R. V. (2007) · Brain Research · doi:10.1016/j.brainres.2007.02.024 · Cited by 321
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
“However, contrary to the suggestion by Biran et al [35] that chronic inflammation is what accounts for electrode failure, our current data show that electrode performance varies widely from poor to good among our animals, which all showed chronic neuroinflammation.”
BackgroundInfluentialToward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
The impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 266
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
Kozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
“This reactive tissue response degrades the functional performance of the electrode sites over time (Polikov et al 2005, Williams et al 1999, Rousche and Normann 1998, Ward et al 2009, Schwartz et al 2006, Nicolelis et al 2003, Liu et al 1999, 2006).”
BackgroundOver-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Self-citationWIMAGINE: Wireless 64-Channel ECoG Recording Implant for Long Term Clinical Applications
Mestais, C. S., Charvet, G., Sauter-Starace, F., Foerster, M., Ratel, D., & Benabid, A. L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2333541 · Cited by 202
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
Winslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
He, W., McConnell, G. C., & Bellamkonda, R. V. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/009 · Cited by 177
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
“Various groups have focused on the astrocyte reaction as the major contributor to chronic recording failure, hypothesizing that a progressive increase in the astrocyte response has the potential to wall off the electrode [13e15], or push neurons away from the recording zone [9].”
Intracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154
Tien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
Ceramic-Based Multisite Electrode Arrays for Chronic Single-Neuron Recording
Moxon, K. A., Leiser, S., Gerhardt, G. A., Barbee, K. A., & Chapin, J. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821037 · Cited by 129
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
“Astrocyte hypertrophy surrounding implanted microelectrodes has been put forward as a major contributor to chronic recording inconsistencies and failure (Liu et al., 1999).”
BackgroundLecomte, A., Castagnola, V, Descamps, E., Dahan, L., Blatché, M. C., Dinis, T. M., Leclerc, E., Egles, C., & Bergaud, C. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/12/125003 · Cited by 110
“The glial scar formation at the electrode/biological tissues interface is considered as the principal source of electrode failure because it increases the distance between the electrode and its targeted neurons, thus decreasing or even losing signal quality [3, 4].”
BackgroundLewis, P. M., & Rosenfeld, J. V. (2016) · Brain Research · doi:10.1016/j.brainres.2015.08.038 · Cited by 107
Development of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity
Fernández, E., Pelayo, F., Romero, S., Bongard, M., Marin, C., Alfaro, A., & Merabet, L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r01 · Cited by 105
Torab, K., Davis, T. S., Warren, D. J., House, P. A., Normann, R. A., & Greger, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035001 · Cited by 90
In vivo evaluation of a neural stem cell-seeded prosthesis
Purcell, E. K., Seymour, J. P., Yandamuri, S., & Kipke, D. R. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026005 · Cited by 76
The effects of chronic intracortical microstimulation on neural tissue and fine motor behavior
Rajan, A. T., Boback, J. L., Dammann, J. F., Tenore, F. V., Wester, B. A., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066018 · Cited by 76
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
Conductively coupled flexible silicon electronic systems for chronic neural electrophysiology
Li, J., Song, E., Chiang, C.-H., Yu, K. J., Koo, J., Du, H., Zhong, Y., Hill, M., Wang, C., Zhang, J., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813187115 · Cited by 65
Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality
Purcell, E. K., Thompson, D. E., Ludwig, K. A., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.026 · Cited by 62
Skousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61
The effect of chronic intracortical microstimulation on the electrode–tissue interface
Chen, K. H., Dammann, J. F., Boback, J. L., Tenore, F. V., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026004 · Cited by 59
Sharma, G., Annetta, N., Friedenberg, D., Blanco, T., Vasconcelos, D., Shaikhouni, A., Rezai, A. R., & Bouton, C. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00010 · Cited by 41
Navarro, X., Lago, N., Vivo, M., Yoshida, K., Koch, K. P., Poppendieck, W., & Micera, S. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428492 · Cited by 36
Eleryan, A., Vaidya, M., Southerland, J., Badreldin, I. S., Balasubramanian, K., Fagg, A. H., Hatsopoulos, N., & Oweiss, K. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00023 · Cited by 20
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Metadata
- Authors
- Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1999
- Volume
- 7
- Issue
- 3
- Pages
- 315-326
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2110482133
- Cited by
- 271
- References
- 14
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.