Five Years of Dispersive Liquid–Liquid Microextraction
The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
: The present article offers a historical overview and a comprehensive collection of publications devoted to dispersive liquid–liquid microextraction (DLLME), including modifications made to it and techniques derived from it. The principle of DLLME is discussed, as are the detection techniques employed, their applications, and milestones in the development of DLLME. The applications and the most important parameters of dispersive liquid–liquid microextraction and related techniques are summarized in a table.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 1×
“(1) introduced a new microextraction technique called dispersive liquid–liquid microextraction (DLLME), which immediately received the interest of researchers and soon became very popular in the field of sample preparation in analytical chemistry, a fact that can be confirmed by the continually growing number of paper…”
BackgroundBerijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Leong, M.-I., & Huang, S.-D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.111 · Cited by 413
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Rezaee, M., Yamini, Y., Shariati, S., Esrafili, A., & Shamsipur, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.091 · Cited by 336
Nagaraju, D., & Huang, S.-D. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.065 · Cited by 312
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Liu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
Liang, P., Xu, J., & Li, Q. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.025 · Cited by 276
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.03.005 · Cited by 258
Xu, H., Ding, Z., Lv, L., Song, D., & Feng, Y.-Q. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.01.028 · Cited by 256
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.094 · Cited by 248
Farajzadeh, M. A., Bahram, M., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.040 · Cited by 234
Xiong, J., & Hu, B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.03.072 · Cited by 228
He, L., Luo, X., Xie, H., Wang, C., Jiang, X., & Lu, K. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.09.044 · Cited by 212
Fu, L., Liu, X., Hu, J., Zhao, X., Wang, H., & Wang, X. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.11.020 · Cited by 210
Fariña, L., Boido, E., Carrau, F., & Dellacassa, E. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.006 · Cited by 209
Farahani, H., Norouzi, P., Dinarvand, R., & Ganjali, M. R. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.001 · Cited by 206
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Dispersive liquid–liquid microextraction using extraction solvent lighter than water
Farajzadeh, M. A., Seyedi, S. E., Shalamzari, M. S., & Bamorowat, M. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900109 · Cited by 196
Chen, H., Chen, H., Ying, J., Huang, J., & Liao, L. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.10.068 · Cited by 184
Fattahi, N., Samadi, S., Assadi, Y., & Hosseini, M. R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.002 · Cited by 178
Wu, Q., Wang, C., Liu, Z., Wu, C., Zeng, X., Wen, J., & Wang, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.062 · Cited by 174
Zhao, E., Zhao, W., Han, L., Jiang, S., & Zhou, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.069 · Cited by 170
Wu, Q., Li, Y., Wang, C., Liu, Z., Zang, X., Zhou, X., & Wang, Z. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.02.017 · Cited by 168
Rezaee, M., Yamini, Y., Khanchi, A., Faraji, M., & Saleh, A. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.02.006 · Cited by 166
Yamini, Y., Rezaee, M., Khanchi, A., Faraji, M., & Saleh, A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.046 · Cited by 165
Rezaei, F., Bidari, A., Birjandi, A. P., Milani Hosseini, M. R., & Assadi, Y. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.02.005 · Cited by 164
Ravelo-Pérez, L. M., Hernández-Borges, J., Asensio-Ramos, M., & Rodríguez-Delgado, M. Á. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.08.012 · Cited by 156
YAZDI, A., RAZAVI, N., & YAZDINEJAD, S. (2008) · Talanta · doi:10.1016/j.talanta.2008.01.039 · Cited by 155
One-step in-syringe ionic liquid-based dispersive liquid–liquid microextraction
Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.040 · Cited by 154
Chang, C.-C., & Huang, S.-D. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.003 · Cited by 152
Leong, M.-I., & Huang, S.-D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.004 · Cited by 151
Xiong, C., Ruan, J., Cai, Y., & Tang, Y. (2009) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.11.036 · Cited by 145
López-Darias, J., Germán-Hernández, M., Pino, V., & Afonso, A. M. (2010) · Talanta · doi:10.1016/j.talanta.2009.09.057 · Cited by 142
Zhou, Q., Zhao, N., & Xie, G. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.01.123 · Cited by 138
Montes, R., Rodríguez, I., Ramil, M., Rubí, E., & Cela, R. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.048 · Cited by 132
Lili, L., Xu, H., Song, D., Cui, Y., Hu, S., & Zhang, G. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.081 · Cited by 123
Hashemi, P., Beyranvand, S., Mansur, R. S., & Ghiasvand, A. R. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.09.034 · Cited by 122
Moinfar, S., & Hosseini, M.-R. M. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.04.030 · Cited by 120
Gao, Z., & Ma, X. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.019 · Cited by 119
Jia, X., Han, Y., Liu, X., Duan, T., & Chen, H. (2011) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2010.12.003 · Cited by 119
Cunha, S. C., Fernandes, J. O., & Oliveira, M. B. P. P. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.051 · Cited by 115
Automated on-line dispersive liquid–liquid microextraction based on a sequential injection system
Andruch, V., Acebal, C. C., Škrlíková, J., Sklenářová, H., Solich, P., Balogh, I. S., Billes, F., & Kocúrová, L. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.09.006 · Cited by 115
Self-citationOzcan, S., Tor, A., & Aydin, M. E. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.037 · Cited by 113
Cortada, C., Vidal, L., Pastor, R., Santiago, N., & Canals, A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.041 · Cited by 112
Li, Y., Wei, G., Hu, J., Liu, X., Zhao, X., & Wang, X. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.03.038 · Cited by 109
Cunha, S. C., & Fernandes, J. O. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.08.066 · Cited by 107
Liu, X., Li, J., Zhao, Z., Zhang, W., Lin, K., Huang, C., & Wang, X. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.092 · Cited by 106
Ebrahimzadeh, H., Yamini, Y., & Kamarei, F. (2009) · Talanta · doi:10.1016/j.talanta.2009.06.022 · Cited by 99
Tsai, W.-H., Chuang, H.-Y., Chen, H.-H., Huang, J.-J., Chen, H.-C., Cheng, S.-H., & Huang, T.-C. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.10.008 · Cited by 98
Melwanki, M. B., Chen, W.-S., Bai, H.-Y., Lin, T.-Y., & Fuh, M.-R. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.021 · Cited by 93
Hashemi, P., Raeisi, F., Ghiasvand, A. R., & Rahimi, A. (2010) · Talanta · doi:10.1016/j.talanta.2009.10.051 · Cited by 92
Daneshfar, A., Khezeli, T., & Lotfi, H. J. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.050 · Cited by 90
Huang, K.-J., Wei, C.-Y., Liu, W.-L., Xie, W.-Z., Zhang, J.-F., & Wang, W. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.070 · Cited by 89
Berton, P., Martinis, E. M., & Wuilloud, R. G. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.11.094 · Cited by 88
Abdolmohammad-Zadeh, H., & Sadeghi, G. H. (2010) · Talanta · doi:10.1016/j.talanta.2010.01.012 · Cited by 86
Sereshti, H., Karimi, M., & Samadi, S. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.081 · Cited by 85
Melwanki, M. B., & Fuh, M.-R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.007 · Cited by 81
Leong, M.-I., Chang, C.-C., Fuh, M.-R., & Huang, S.-D. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.06.056 · Cited by 80
Zang, X., Wang, J., Wang, O., Wang, M., Ma, J., Xi, G., & Wang, Z. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2296-1 · Cited by 75
Wu, C., Liu, H., Liu, W., Wu, Q., Wang, C., & Wang, Z. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3790-9 · Cited by 74
Mashayekhi, H. A., Abroomand-Azar, P., Saber-Tehrani, M., & Husain, S. W. (2010) · Chromatographia · doi:10.1365/s10337-009-1456-6 · Cited by 71
Hu, J., Fu, L., Zhao, X., Liu, X., Wang, H., Wang, X., & Dai, L. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.02.055 · Cited by 71
Ma, J., Zhang, J., Du, X., Lei, X., & Li, J. (2010) · Microchimica Acta · doi:10.1007/s00604-009-0275-7 · Cited by 71
Ionic liquid based dispersive liquid–liquid microextraction of aromatic amines in water samples
Fan, Y. C., Hu, Z. L., Chen, M. L., Tu, C. S., & Zhu, Y. (2008) · Chinese Chemical Letters · doi:10.1016/j.cclet.2008.05.024 · Cited by 70
Dai, L., Cheng, J., Matsadiq, G., Liu, L., & Li, J.-K. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.023 · Cited by 69
Bai, H., Zhou, Q., Xie, G., & Xiao, J. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.011 · Cited by 67
Ravelo-Pérez, L. M., Hernández-Borges, J., Herrera-Herrera, A. V., & Rodríguez-Delgado, M. Á. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3133-x · Cited by 64
LC Determination of Chloramphenicol in Honey Using Dispersive Liquid–Liquid Microextraction
Chen, H., Ying, J., Chen, H., Huang, J., & Liao, L. (2008) · Chromatographia · doi:10.1365/s10337-008-0753-9 · Cited by 62
Rivas, R. E., López-García, I., & Hernández-Córdoba, M. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0206-7 · Cited by 62
Pusvaskiene, E., Januskevic, B., Prichodko, A., & Vickackaite, V. (2009) · Chromatographia · doi:10.1365/s10337-008-0885-y · Cited by 57
Hu, J., Li, Y., Zhang, W., Wang, H., Huang, C., Zhang, M., & Wang, X. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900027 · Cited by 51
Wang, X., Fu, L., Wei, G., Hu, J., Zhao, X., Liu, X., & Li, Y. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800273 · Cited by 51
Li, Y., Hu, J., Liu, X., Fu, L., Zhang, X., & Wang, X. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800112 · Cited by 49
Wei, S.-Y., Leong, M.-I., Li, Y., & Huang, S.-D. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.084 · Cited by 47
Wang, X., Diao, C., & Zhao, R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800436 · Cited by 47
Vickackaite, V., & Pusvaskiene, E. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900360 · Cited by 45
A ionic liquid for dispersive liquid-liquid microextraction of phenols
Fan, Y. C., Chen, M. L., Shen-Tu, C., & Zhu, Y. (2009) · Journal of Analytical Chemistry · doi:10.1134/s1061934809100074 · Cited by 43
Sobhi, H. R., Kashtiaray, A., Farahani, H., Javaheri, M., & Ganjali, M. R. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.09.161 · Cited by 40
Liu, X., Hu, J., Huang, C., Wang, H., & Wang, X. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900480 · Cited by 40
Xu, H., Song, D., Cui, Y., Hu, S., Yu, Q.-W., & Feng, Y.-Q. (2009) · Chromatographia · doi:10.1365/s10337-009-1208-7 · Cited by 37
Farajzadeh, M. A., Vardast, M. R., & Bahram, M. (2009) · Chromatographia · doi:10.1365/s10337-008-0912-z · Cited by 36
Zhou, Q., Zhang, X., Xie, G., & Xiao, J. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900444 · Cited by 33
Bernardo, M. S., Gonçalves, M., Lapa, N., Barbosa, R., Mendes, B., Pinto, F., & Gulyurtlu, I. (2009) · Talanta · doi:10.1016/j.talanta.2009.06.037 · Cited by 26
Cited by
Protic Ionic Liquids: Evolving Structure–Property Relationships and Expanding Applications
Greaves, T. L., & Drummond, C. J. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00158 · Cited by 877
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
“recently summarized the applications involving DLLME in the past five years [10], whereas Ma et al.”
BackgroundLiquid–phase microextraction: A review of reviews
Rutkowska, M., Płotka-Wasylka, J., Sajid, M., & Andruch, V. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.103989 · Cited by 244
Self-citationDispersive liquid–liquid microextraction in food analysis. A critical review
Viñas, P., Campillo, N., López-García, I., & Hernández-Córdoba, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7344-9 · Cited by 211
“[219] Historical overview, milestones, and applications Andruch et al.”
BackgroundZounr, R. A., Tuzen, M., Deligonul, N., & Khuhawar, M. Y. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.01.167 · Cited by 127
Metadata
- Authors
- Andruch, V., Balogh, I. S., Kocúrová, L., & Šandrejová, J.
- Venue
- Applied Spectroscopy Reviews
- Publisher
- Informa UK Limited
- Published
- 2013-04
- Volume
- 48
- Issue
- 3
- Pages
- 161-259
- ISSN
- 0570-4928 (ISSN-L)
- 1520-569X
- OpenAlex
- W2024061956
- Cited by
- 83
- References
- 88
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.