Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
The DOI matches its Crossref record; 259 of the 259 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS) is the most comprehensive and versatile tool in large-scale proteomics. In this review, we dissect the overall framework of the MS experiment into its key components. We discuss the fundamentals of proteomic analyses as well as recent developments in the areas of separation methods, instrumentation, and overall experimental design. We highlight both the inherent strengths and limitations of protein MS and offer a rough guide for selecting an experimental design based on the goals of the analysis. We emphasize the versatility of the Orbitrap, a novel mass analyzer that features high resolution (up to 150,000), high mass accuracy (2–5 ppm), a mass-to-charge range of 6000, and a dynamic range greater than 10 3. High mass accuracy of the Orbitrap expands the arsenal of the data acquisition and analysis approaches compared with a low-resolution instrument. We discuss various chromatographic techniques, including multidimensional separation and ultra-performance liquid chromatography. Multidimensional protein identification technology (MudPIT) involves a continuum sample preparation, orthogonal separations, and MS and software solutions. We discuss several aspects of MudPIT applications to quantitative phosphoproteomics. MudPIT application to large-scale analysis of phosphoproteins includes (a) a fractionation procedure for motif-specific enrichment of phosphopeptides, (b) development of informatics tools for interrogation and validation of shotgun phosphopeptide data, and (c) in-depth data analysis for simultaneous determination of protein expression and phosphorylation levels, analog to western blot measurements. We illustrate MudPIT application to quantitative phosphoproteomics of the beta adrenergic pathway. We discuss several biological discoveries made via mass spectrometry pipelines with a focus on cell signaling proteomics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Mass spectrometry (MS)-based proteomics has emerged as the most versatile and comprehensive strategy for protein characterization [8,9].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [9]
In the citing paper
“Mass spectrometry (MS)–based methods continue to be the most widely used methods for high-throughput proteomics research1–4”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [2]
Citations
Cites
Initial sequencing and analysis of the human genome
International Human Genome Sequencing Consortium, Whitehead Institute for Biomedical Research, C. F. G. R., Lander, E. S., Linton, L. M., Birren, B., Nusbaum, C., Zody, M. C., Baldwin, J., Devon, K., Dewar, K., et al. (2001) · Nature · doi:10.1038/35057062 · Cited by 24,216 · cited 1×
“Whole-genome sequencing efforts of the past century have produced many fully sequenced genomes, punctuated by the completion of the Human Genome Project (1, 2).”
The sequence of the human genome
Venter, J. C., Adams, M. D., Myers, E. W., Li, P. W., Mural, R. J., Sutton, G. G., Smith, H. O., Yandell, M., Evans, C. A., Holt, R. A., et al. (2001) · Science · doi:10.1126/science.1058040 · Cited by 13,909
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Schena, M., Shalon, D., Davis, R. W., & Brown, P. O. (1995) · Science · doi:10.1126/science.270.5235.467 · Cited by 9,609
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 18×
“F or p er so na l u se o nl y. Table 2 Approaches in mass spectrometry proteomicsa Prerequisite Advantages Drawbacks Applications Front end Analysis Top down High mass accuracy instruments High sequence coverage Precursor ion charge state limitations Single-protein characterization Ion-exchange chromatography EST LTQ-…”
MethodInfluentialMass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955 · cited 1×
“Phosphoproteomics is geared toward the identification and quantification of phosphorylated proteins and the identification of phosphorylation sites (108, 109).”
BackgroundEng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 2×
“Since the original publication of SEQUEST (132) in 1994, many methods have been developed that address some of the computational challenges associated with bottom-up proteomics.”
MethodSelf-citationLaser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · cited 2×
“The SILAC approach labels proteins with one or more heavy amino acids: Leu (180), Arg, Lys (166), and/or Tyr (181).”
MethodKeller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752 · cited 1×
“The 2D SCX chromatography followed by RPLC has become a popular method in shotgun proteomics known as multidimensional protein identification technology (MudPIT) (80, 97, 100).”
MethodSelf-citationQuantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · cited 4×
“Examples of chemical derivatization techniques for quantitative proteomics include isotope-coded affinity tags (ICAT), used for the labeling of free cysteine (148), and isobaric tags for relative and absolute quantification (iTRAQ), used for the labeling of free amines (170).”
BackgroundMethodInfluentialRoss, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · cited 2×
“Initially, iTRAQ experiments were carried out on Q-TOF instruments (170, 175) because quadrupole (176) and TOF instruments are capable of detecting low m/z fragment ions in the region of the iTRAQ reporter ions, unlike ion traps in which recovery of ions in the mass range below 30% of the precursor’s ion mass is very…”
MethodElias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925 · cited 1×
“As with any database search, the decoy database is used to filter out false-positive identification (218).”
MethodGlobal analysis of protein expression in yeast
Ghaemmaghami, S., Huh, W.-K., Bower, K., Howson, R. W., Belle, A., Dephoure, N., O'Shea, E. K., & Weissman, J. S. (2003) · Nature · doi:10.1038/nature02046 · Cited by 3,750 · cited 1×
“Whereas DNA microarray technology is based on a highly sensitive and specific hybridization reaction between nucleic acid fragments, inherent limitations of biological MS (8) require several different approaches to protein analysis.”
MethodGlobal, In Vivo, and Site-Specific Phosphorylation Dynamics in Signaling Networks
Olsen, J. V., Blagoev, B., Gnad, F., Macek, B., Kumar, C., Mortensen, P., & Mann, M. (2006) · Cell · doi:10.1016/j.cell.2006.09.026 · Cited by 3,499
Sequence logos: a new way to display consensus sequences
Schneider, T. D., & Stephens, R. M. (1990) · Nucleic Acids Research · doi:10.1093/nar/18.20.6097 · Cited by 3,378 · cited 1×
“Direct application of sequence logos (239) identified strongly favored residues precipitated by Ba2+/acetone (Figure 5).”
BackgroundDisintegration of water drops in an electric field
Taylor, G. I. (1964) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1964.0151 · Cited by 3,305 · cited 1×
“Physicochemical processes of ESI involve creation of electrically charged spray, Taylor cone (22), followed by formation and desolvation of analyte-solvent droplets.”
BackgroundSequence and structure-based prediction of eukaryotic protein phosphorylation sites
Blom, N., Gammeltoft, S., & Brunak, S. (1999) · Journal of Molecular Biology · doi:10.1006/jmbi.1999.3310 · Cited by 3,188 · cited 1×
“Yet other bioinformatics algorithms, such as artificial neural networks (238), can further refine the list of kinase-preferred sites.”
ATM and ATR Substrate Analysis Reveals Extensive Protein Networks Responsive to DNA Damage
Matsuoka, S., Ballif, B. A., Smogorzewska, A., McDonald, E. R., Hurov, K. E., Luo, J., Bakalarski, C. E., Zhao, Z., Solimini, N., Lerenthal, Y., et al. (2007) · Science · doi:10.1126/science.1140321 · Cited by 3,075 · cited 1×
“More recently, a panel of 68 antibodies specific for SQ/TQ motifs enriched the subproteome involved in the response to DNA damage (235).”
BackgroundA Model for Random Sampling and Estimation of Relative Protein Abundance in Shotgun Proteomics
Liu, H., Sadygov, R. G., & Yates, J. R. (2004) · Analytical Chemistry · doi:10.1021/ac0498563 · Cited by 2,500 · cited 1×
“Spectral sampling is directly proportional to the relative abundance of the protein in the mixture (190).”
BackgroundSelf-citationThompson, A., Schäfer, J., Kuhn, K., Kienle, S., Schwarz, J., Schmidt, G., Neumann, T., & Hamon, C. (2003) · Analytical Chemistry · doi:10.1021/ac0262560 · Cited by 2,378 · cited 1×
“Techniques such as ICAT (148), O18 labeling (149), and Hamon tandem mass tags (150) work best with flexible and accessible peptides.”
BackgroundProteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373 · cited 1×
“However, the high-pressure reverse phase chromatography is as essential to LC/MS as 2D PAGE is to gel-based proteomics (27, 78).”
MethodPeptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370 · cited 5×
“Alternative fragmentation reactions, such as electron capture dissociation (ECD) (67) and electron transfer dissociation (ETD) (151, 152), that yield a more complete backbone sequencing and retain labile PTMs (153) are the preferred fragmentation methods of the top-down approach. www.annualreviews.org • Proteomics by…”
MethodInfluentialGlobal Survey of Phosphotyrosine Signaling Identifies Oncogenic Kinases in Lung Cancer
Rikova, K., Guo, A., Zeng, Q., Possemato, A., Yu, J., Haack, H., Nardone, J., Lee, K., Reeves, C., Li, Y., et al. (2007) · Cell · doi:10.1016/j.cell.2007.11.025 · Cited by 2,317 · cited 1×
“Proteome-scale screening of phosphotyrosines has been extended to the identification of oncogenic kinases (209), identification of core proteins responding to drug treatment (210), and definition of the organspecific phosphorylation (201).”
BackgroundDirect analysis of protein complexes using mass spectrometry
Link, A. J., Eng, J., Schieltz, D. M., Carmack, E., Mize, G. J., Morris, D. R., Garvik, B. M., & Yates, J. R. (1999) · Nature Biotechnology · doi:10.1038/10890 · Cited by 2,237 · cited 2×
“The term shotgun proteomics (33, 80, 97) is the protein equivalent to shotgun genomic sequencing in which the DNA is sheared and sequenced in smaller overlapping contigs.”
BackgroundMethodSelf-citationMass Spectrometry and Protein Analysis
Domon, B., & Aebersold, R. (2006) · Science · doi:10.1126/science.1124619 · Cited by 2,181 · cited 2×
“Label-free methods use either spectral counting or peptide signal intensity to estimate abundance of proteins (37).”
BackgroundMethodProteomic analysis of post-translational modifications
Mann, M., & Jensen, O. N. (2003) · Nature Biotechnology · doi:10.1038/nbt0303-255 · Cited by 2,134 · cited 1×
“Phosphoproteomics is geared toward the identification and quantification of phosphorylated proteins and the identification of phosphorylation sites (108, 109).”
BackgroundMatrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881 · cited 4×
“Alternative fragmentation reactions, such as electron capture dissociation (ECD) (67) and electron transfer dissociation (ETD) (151, 152), that yield a more complete backbone sequencing and retain labile PTMs (153) are the preferred fragmentation methods of the top-down approach.”
MethodInfluentialAn Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
Wolters, D. A., Washburn, M. P., & Yates, J. R. (2001) · Analytical Chemistry · doi:10.1021/ac010617e · Cited by 1,819 · cited 4×
“Other materials used as first dimension (1D) are size exclusion (97), anion-exchange, (105) and a mixed-bed approach (106).”
BackgroundMethodInfluentialSelf-citationAbsolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733 · cited 1×
“Absolute measurements of protein concentrations can be achieved with spiked synthetic peptides (171), artificial proteins derived from detected peptides, as in QconCAT (172), and SILAC (173).”
BackgroundExpression profiling using cDNA microarrays
Duggan, D. J., Bittner, M., Chen, Y., Meltzer, P., & Trent, J. M. (1999) · Nature Genetics · doi:10.1038/4434 · Cited by 1,657
Phosphoproteome analysis by mass spectrometry and its application to Saccharomyces cerevisiae
Ficarro, S. B., McCleland, M. L., Stukenberg, P. T., Burke, D. J., Ross, M. M., Shabanowitz, J., Hunt, D. F., & White, F. M. (2002) · Nature Biotechnology · doi:10.1038/nbt0302-301 · Cited by 1,636 · cited 4×
“The IMAC selectivity and specificity can be altered with different buffer conditions, such as pH, salt concentration (112), buffer composition, and the presence of detergents (113).”
BackgroundInfluentialA quantitative atlas of mitotic phosphorylation
Dephoure, N., Zhou, C., Villén, J., Beausoleil, S. A., Bakalarski, C. E., Elledge, S. J., & Gygi, S. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805139105 · Cited by 1,608 · cited 3×
“Recent studies quantified both phosphorylation levels and protein levels for mitotic phosphorylation (223), cell cycle kinases (251), and the beta-adrenergic pathway (206) (Figure 6).”
BackgroundBeausoleil, S. A., Villén, J., Gerber, S. A., Rush, J., & Gygi, S. P. (2006) · Nature Biotechnology · doi:10.1038/nbt1240 · Cited by 1,577 · cited 1×
“This is followed by phosphorylation site localization that describes positions of phosphorylated residues (221, 222).”
BackgroundMass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · cited 4×
“For the stable isotope labeling by amino acids in cell culture (SILAC) approach, cell media contain (13)C6-Lys and (13)C6, and (15)N4-Arg for comprehensive labeling of tryptic cleavage products (166).”
BackgroundMethodInfluentialOlsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510 · cited 1×
“There are several papers that review and benchmark the performance of the Orbitrap for bottom-up (32, 33, 35, 56, 57) and top-down (58, 59) proteomic applications.”
BackgroundLarsen, M. R., Thingholm, T. E., Jensen, O. N., Roepstorff, P., & Jørgensen, T. J. D. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500007-mcp200 · Cited by 1,476 · cited 1×
“By limiting nonspecific interactions, 2,5-dihydroxybenzoic acid (DHB) (204) and aliphatic hydroxyl acids (205) increase selectivity of TiO2.”
BackgroundMechanisms of specificity in protein phosphorylation
Ubersax, J. A., & Ferrell Jr, J. E. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2203 · Cited by 1,451
Zhang, H., Li, X.-J., Martin, D. B., & Aebersold, R. (2003) · Nature Biotechnology · doi:10.1038/nbt827 · Cited by 1,389 · cited 1×
“N-linked glycosylated peptides are selectively bound to the solid support (121) and are subsequently enzymatically released.”
BackgroundLarge-scale characterization of HeLa cell nuclear phosphoproteins
Beausoleil, S. A., Jedrychowski, M., Schwartz, D., Elias, J. E., Villén, J., Li, J., Cohn, M. A., Cantley, L. C., & Gygi, S. P. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404720101 · Cited by 1,375 · cited 1×
“To account for the ubiquitous presence of phosphate neutral losses, a neutral loss–triggered MS3 data– acquisition method has been introduced for phosphoproteome analysis (213).”
MethodTabb, D. L., McDonald, W. H., & Yates, J. R. (2002) · Journal of Proteome Research · doi:10.1021/pr015504q · Cited by 1,367
Self-citationThe Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Evaluation of two-dimensional gel electrophoresis-based proteome analysis technology
Gygi, S. P., Corthals, G. L., Zhang, Y., Rochon, Y., & Aebersold, R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.160270797 · Cited by 1,319 · cited 1×
“High-complexity large-scale proteomic samples contain thousands of proteins that can range upward of five orders of magnitude in their abundance (96).”
BackgroundOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Klose, J. (1975) · Humangenetik · doi:10.1007/bf00281458 · Cited by 1,207
Immunoaffinity profiling of tyrosine phosphorylation in cancer cells
Rush, J., Moritz, A., Lee, K. A., Guo, A., Goss, V. L., Spek, E. J., Zhang, H., Zha, X.-M., Polakiewicz, R. D., & Comb, M. J. (2005) · Nature Biotechnology · doi:10.1038/nbt1046 · Cited by 1,124 · cited 1×
“Compared with the serine and threonine phosphorylation, investigation of the phosphotyrosine proteome relies almost exclusively on immunoaffinity purifications (208).”
BackgroundQuantitative chemical proteomics reveals mechanisms of action of clinical ABL kinase inhibitors
Bantscheff, M., Eberhard, D., Abraham, Y., Bastuck, S., Boesche, M., Hobson, S., Mathieson, T., Perrin, J., Raida, M., Rau, C., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1328 · Cited by 1,034 · cited 1×
“This approach combined with iTRAQ and MS revealed new drug targets selected from cell lysates (253).”
MethodElectrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009 · cited 16×
“F or p er so na l u se o nl y. Table 2 Approaches in mass spectrometry proteomicsa Prerequisite Advantages Drawbacks Applications Front end Analysis Top down High mass accuracy instruments High sequence coverage Precursor ion charge state limitations Single-protein characterization Ion-exchange chromatography EST LTQ-…”
MethodInfluentialAccurate quantitation of protein expression and site-specific phosphorylation
Oda, Y., Huang, K., Cross, F. R., Cowburn, D., & Chait, B. T. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.12.6591 · Cited by 1,006 · cited 1×
“In early studies, total labeling of yeast has been achieved using 15N-enriched cell culture media (167).”
BackgroundHigher-energy C-trap dissociation for peptide modification analysis
Olsen, J. V., Macek, B., Lange, O., Makarov, A., Horning, S., & Mann, M. (2007) · Nature Methods · doi:10.1038/nmeth1060 · Cited by 999 · cited 1×
“Another alternative for structural characterization of phosphopeptides using high mass accuracy may be high-energy collision-induced dissociation (HCD) (217) carried out in a separate octapole collision cell added to the LTQ-Orbitrap.”
BackgroundThe Age of Crosstalk: Phosphorylation, Ubiquitination, and Beyond
Hunter, T. (2007) · Molecular Cell · doi:10.1016/j.molcel.2007.11.019 · Cited by 942 · cited 1×
“For example, two or more modifications can directly compete for the same single residue in a negative cross talk (230).”
BackgroundDesiere, F. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj040 · Cited by 910
On target with a new mechanism for the regulation of protein phosphorylation
Hubbard, M. J., & Cohen, P. (1993) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(93)90109-z · Cited by 903 · cited 1×
“Immobilized metal affinity chromatography (IMAC) (110) has become a popular method whereby immobilized Fe3+ ions (111) are used to selectively bind phosphorylated peptides.”
BackgroundPinkse, M. W. H., Uitto, P. M., Hilhorst, M. J., Ooms, B., & Heck, A. J. R. (2004) · Analytical Chemistry · doi:10.1021/ac0498617 · Cited by 891 · cited 2×
“Other metal oxide affinity resins are TiO2 (116), Fe3O4 (117), and ZrO2 (118).”
BackgroundMethodSchwartz, D., & Gygi, S. P. (2005) · Nature Biotechnology · doi:10.1038/nbt1146 · Cited by 879
Membrane proteins and proteomics: Un amour impossible?
Santoni, V., Molloy, M., & Rabilloud, T. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1054::aid-elps1054>3.0.co;2-8 · Cited by 852
A two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796 · cited 2×
“The LTQ ion trap (54) from Thermo Scientific combines a tenfold-higher ion storage capacity than 3D traps and high resolution at a fast scanning rate (5555 Da s−1).”
BackgroundA common open representation of mass spectrometry data and its application to proteomics research
Pedrioli, P. G. A., Eng, J. K., Hubley, R., Vogelzang, M., Deutsch, E. W., Raught, B., Pratt, B., Nilsson, E., Angeletti, R. H., Apweiler, R., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt1031 · Cited by 780
Quantitative Phosphoproteomics Applied to the Yeast Pheromone Signaling Pathway
Gruhler, A., Olsen, J. V., Mohammed, S., Mortensen, P., Færgeman, N. J., Mann, M., & Jensen, O. N. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400219-mcp200 · Cited by 763 · cited 1×
“Numerous studies applied SILAC to studying dynamic changes in response to stimuli (182, 183).”
Mass spectrometry for proteomics
Han, X., Aslanian, A., & Yates, J. R. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.07.024 · Cited by 734
Self-citationLarge-scale phosphorylation analysis of mouse liver
Villén, J., Beausoleil, S. A., Gerber, S. A., & Gygi, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609836104 · Cited by 730 · cited 2×
“Proteome-scale screening of phosphotyrosines has been extended to the identification of oncogenic kinases (209), identification of core proteins responding to drug treatment (210), and definition of the organspecific phosphorylation (201).”
BackgroundMethodKlose, J., & Kobalz, U. (1995) · ELECTROPHORESIS · doi:10.1002/elps.11501601175 · Cited by 714
Open Source System for Analyzing, Validating, and Storing Protein Identification Data
Craig, R., Cortens, J. P., & Beavis, R. C. (2004) · Journal of Proteome Research · doi:10.1021/pr049882h · Cited by 694
A uniform proteomics MS/MS analysis platform utilizing open XML file formats
Keller, A., Eng, J., Zhang, N., Li, X., & Aebersold, R. (2005) · Molecular Systems Biology · doi:10.1038/msb4100024 · Cited by 693
Recent advancements in surface-enhanced laser desorption/ionization-time of flight-mass spectrometry
Merchant, M., & Weinberger, S. R. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1164::aid-elps1164>3.0.co;2-0 · Cited by 693 · cited 1×
“The concept of MALDI has led to techniques such as surface-enhanced laser desorption ionization (SELDI) (21) that introduce surface affinity toward various protein and peptide molecules.”
BackgroundTemporal analysis of phosphotyrosine-dependent signaling networks by quantitative proteomics
Blagoev, B., Ong, S.-E., Kratchmarova, I., & Mann, M. (2004) · Nature Biotechnology · doi:10.1038/nbt1005 · Cited by 681 · cited 1×
“Several studies investigated activation of the epidermal growth factor receptor (EGFR) signaling pathway (175, 249).”
BackgroundKrüger, M., Moser, M., Ussar, S., Thievessen, I., Luber, C. A., Forner, F., Schmidt, S., Zanivan, S., Fässler, R., & Mann, M. (2008) · Cell · doi:10.1016/j.cell.2008.05.033 · Cited by 680 · cited 1×
“Recently, SILAC has been applied to labeling of primary cells (184) and mice (185).”
MethodMaking and reading microarrays
Cheung, V. G., Morley, M., Aguilar, F., Massimi, A., Kucherlapati, R., & Childs, G. (1999) · Nature Genetics · doi:10.1038/4439 · Cited by 662
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605 · cited 1×
“Some of the benefits of the top-down approach include higher sequence coverage of target proteins (157) and better characterization of the posttranslational modifications (158, 159).”
BackgroundDaub, H., Olsen, J. V., Bairlein, M., Gnad, F., Oppermann, F. S., Körner, R., Greff, Z., Kéri, G., Stemmann, O., & Mann, M. (2008) · Molecular Cell · doi:10.1016/j.molcel.2008.07.007 · Cited by 594 · cited 2×
“Recent studies quantified both phosphorylation levels and protein levels for mitotic phosphorylation (223), cell cycle kinases (251), and the beta-adrenergic pathway (206) (Figure 6).”
BackgroundMethodChi, A., Huttenhower, C., Geer, L. Y., Coon, J. J., Syka, J. E. P., Bai, D. L., Shabanowitz, J., Burke, D. J., Troyanskaya, O. G., & Hunt, D. F. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607084104 · Cited by 564 · cited 1×
“ECD and ETD help to identify different segments of phosphoproteomes (214, 215).”
BackgroundZhang, Y., Wolf-Yadlin, A., Ross, P. L., Pappin, D. J., Rush, J., Lauffenburger, D. A., & White, F. M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500089-mcp200 · Cited by 541 · cited 2×
“Initially, iTRAQ experiments were carried out on Q-TOF instruments (170, 175) because quadrupole (176) and TOF instruments are capable of detecting low m/z fragment ions in the region of the iTRAQ reporter ions, unlike ion traps in which recovery of ions in the mass range below 30% of the precursor’s ion mass is very…”
BackgroundMethodTwo-dimensional separations: concept and promise
Giddings, J. C. (1984) · Analytical Chemistry · doi:10.1021/ac00276a003 · Cited by 537 · cited 1×
“An important consideration for multidimensional separation is the orthogonality of the individual separation methods (98) in which each dimension uses different (orthogonal) molecular properties of molecules as a basis for separation.”
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514 · cited 1×
“There are several papers that review and benchmark the performance of the Orbitrap for bottom-up (32, 33, 35, 56, 57) and top-down (58, 59) proteomic applications.”
BackgroundMicro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510 · cited 3×
“An important development in ESI technique includes microand nano-ESI (26, 27), in which the flow rates are lowered to a nanoliter-per-minute regime to improve the method’s sensitivity.”
BackgroundMethodSignaling networks assembled by oncogenic EGFR and c-Met
Guo, A., Villén, J., Kornhauser, J., Lee, K. A., Stokes, M. P., Rikova, K., Possemato, A., Nardone, J., Innocenti, G., Wetzel, R., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707270105 · Cited by 505 · cited 1×
“Proteome-scale screening of phosphotyrosines has been extended to the identification of oncogenic kinases (209), identification of core proteins responding to drug treatment (210), and definition of the organspecific phosphorylation (201).”
BackgroundDecoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503 · cited 1×
“Some of the benefits of the top-down approach include higher sequence coverage of target proteins (157) and better characterization of the posttranslational modifications (158, 159).”
BackgroundMolina, H., Horn, D. M., Tang, N., Mathivanan, S., & Pandey, A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611217104 · Cited by 502 · cited 1×
“ECD and ETD help to identify different segments of phosphoproteomes (214, 215).”
BackgroundWolf-Yadlin, A., Hautaniemi, S., Lauffenburger, D. A., & White, F. M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608638104 · Cited by 493
Beynon, R. J., Doherty, M. K., Pratt, J. M., & Gaskell, S. J. (2005) · Nature Methods · doi:10.1038/nmeth774 · Cited by 472 · cited 1×
“Absolute measurements of protein concentrations can be achieved with spiked synthetic peptides (171), artificial proteins derived from detected peptides, as in QconCAT (172), and SILAC (173).”
BackgroundSenko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Linear ion traps in mass spectrometry
Douglas, D. J., Frank, A. J., & Mao, D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20004 · Cited by 459 · cited 1×
“Ion trap instruments (33, 53) are the high-throughput workhorses in proteomics.”
BackgroundGnad, F., Ren, S., Cox, J., Olsen, J. V., Macek, B., Oroshi, M., & Mann, M. (2007) · Genome Biology · doi:10.1186/gb-2007-8-11-r250 · Cited by 454 · cited 1×
“Mapped phosphorylation sites and their temporal profiles were deposited in a phosphorylation-site resource database (250).”
MethodShevchenko, A., Chernushevich, I., Ens, W., Standing, K. G., Thomson, B., Wilm, M., & Mann, M. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970615)11:9<1015::aid-rcm958>3.0.co;2-h · Cited by 454 · cited 4×
“Initially, iTRAQ experiments were carried out on Q-TOF instruments (170, 175) because quadrupole (176) and TOF instruments are capable of detecting low m/z fragment ions in the region of the iTRAQ reporter ions, unlike ion traps in which recovery of ions in the mass range below 30% of the precursor’s ion mass is very…”
MethodInfluentialMueller, L. N., Brusniak, M.-Y., Mani, D. R., & Aebersold, R. (2008) · Journal of Proteome Research · doi:10.1021/pr700758r · Cited by 449 · cited 1×
“Automated quantification of complex proteomes necessitates additional software solutions (192).”
BackgroundCovey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Morris, H. R., Paxton, T., Dell, A., Langhorne, J., Berg, M., Bordoli, R. S., Hoyes, J., & Bateman, R. H. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<889::aid-rcm615>3.0.co;2-f · Cited by 446 · cited 4×
“Initially, iTRAQ experiments were carried out on Q-TOF instruments (170, 175) because quadrupole (176) and TOF instruments are capable of detecting low m/z fragment ions in the region of the iTRAQ reporter ions, unlike ion traps in which recovery of ions in the mass range below 30% of the precursor’s ion mass is very…”
MethodInfluentialMass Spectrometry: Bottom-Up or Top-Down?
Chait, B. T. (2006) · Science · doi:10.1126/science.1133987 · Cited by 441
Options available — from start to finish — for obtaining expression data by microarray
Bowtell, D. D. L. (1999) · Nature Genetics · doi:10.1038/4455 · Cited by 439
Sugiyama, N., Masuda, T., Shinoda, K., Nakamura, A., Tomita, M., & Ishihama, Y. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t600060-mcp200 · Cited by 435 · cited 1×
“By limiting nonspecific interactions, 2,5-dihydroxybenzoic acid (DHB) (204) and aliphatic hydroxyl acids (205) increase selectivity of TiO2.”
BackgroundOng, S.-E., Kratchmarova, I., & Mann, M. (2003) · Journal of Proteome Research · doi:10.1021/pr0255708 · Cited by 432 · cited 1×
“Quantitative accuracy, however, requires complete incorporation of the labeled amino acids, as metabolic conversion of arginine to proline results in tryptic peptides containing heavy prolines (186).”
BackgroundDynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Makarov, A., Denisov, E., Lange, O., & Horning, S. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.03.006 · Cited by 431 · cited 1×
“The Orbitrap mass analyzer features high resolution (up to 150,000), high mass accuracy (2– 5 ppm), a mass-to-charge range of 6000, and a dynamic range greater than 103 (40, 42).”
BackgroundAtmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
Laiko, V. V., Baldwin, M. A., & Burlingame, A. L. (2000) · Analytical Chemistry · doi:10.1021/ac990998k · Cited by 411 · cited 1×
“An important development in MALDI ionization is atmospheric pressure MALDI (AP-MALDI) (20).”
BackgroundMetabolic labeling of C. elegans and D. melanogaster for quantitative proteomics
Krijgsveld, J., Ketting, R. F., Mahmoudi, T., Johansen, J., Artal-Sanz, M., Verrijzer, C. P., Plasterk, R. H. A., & Heck, A. J. R. (2003) · Nature Biotechnology · doi:10.1038/nbt848 · Cited by 408 · cited 1×
“In vivo metabolic 15N labeling of model organisms such as Caenorhabditis elegans, Drosophila melanogaster (168), and rat (169) has been reported.”
BackgroundA quantitative analysis software tool for mass spectrometry–based proteomics
Park, S. K., Venable, J. D., Xu, T., & Yates, J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1195 · Cited by 401 · cited 1×
“One such solution is Census, a software tool for analyzing quantitative MS data (189).”
MethodSelf-citationScheele, G. A. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41192-7 · Cited by 391
Metabolic Labeling of Mammalian Organisms with Stable Isotopes for Quantitative Proteomic Analysis
Wu, C. C., MacCoss, M. J., Howell, K. E., Matthews, D. E., & Yates, J. R. (2004) · Analytical Chemistry · doi:10.1021/ac049208j · Cited by 386 · cited 1×
“In vivo metabolic 15N labeling of model organisms such as Caenorhabditis elegans, Drosophila melanogaster (168), and rat (169) has been reported.”
BackgroundSelf-citationProbability-Based Validation of Protein Identifications Using a Modified SEQUEST Algorithm
MacCoss, M. J., Wu, C. C., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac025826t · Cited by 377
Self-citationHillenkamp, F., & Karas, M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93420-p · Cited by 375
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373 · cited 5×
“Alternative fragmentation reactions, such as electron capture dissociation (ECD) (67) and electron transfer dissociation (ETD) (151, 152), that yield a more complete backbone sequencing and retain labile PTMs (153) are the preferred fragmentation methods of the top-down approach. www.annualreviews.org • Proteomics by…”
MethodInfluentialKelleher, N. L., Zubarev, R. A., Bush, K., Furie, B., Furie, B. C., McLafferty, F. W., & Walsh, C. T. (1999) · Analytical Chemistry · doi:10.1021/ac990684x · Cited by 368 · cited 5×
“Alternative fragmentation reactions, such as electron capture dissociation (ECD) (67) and electron transfer dissociation (ETD) (151, 152), that yield a more complete backbone sequencing and retain labile PTMs (153) are the preferred fragmentation methods of the top-down approach. www.annualreviews.org • Proteomics by…”
MethodInfluentialZybailov, B., Coleman, M. K., Florens, L., & Washburn, M. P. (2005) · Analytical Chemistry · doi:10.1021/ac050846r · Cited by 349 · cited 7×
“F or p er so na l u se o nl y. MudPIT: Multidimensional Protein Identification Technology IMAC: immobilized metal affinity chromatography sensitivity due to the high capacity of strong cation-exchange (SCX) resin and the high resolution of SCX and RP.”
MethodInfluentialSyka, J. E. P., Marto, J. A., Bai, D. L., Horning, S., Senko, M. W., Schwartz, J. C., Ueberheide, B., Garcia, B., Busby, S., Muratore, T., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 348
McNulty, D. E., & Annan, R. S. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700543-mcp200 · Cited by 345 · cited 3×
“The following types of HPLC chromatographic materials are most commonly used in MS-based proteomics: ion exchange (IEX), reverse phase, hydrophilicinteraction chromatography (HILIC), affinity, and hybrid materials.”
BackgroundMethodPorous Silicon as a Versatile Platform for Laser Desorption/Ionization Mass Spectrometry
Shen, Z., Thomas, J. J., Averbuj, C., Broo, K. M., Engelhard, M., Crowell, J. E., Finn, M. G., & Siuzdak, G. (2001) · Analytical Chemistry · doi:10.1021/ac000746f · Cited by 333 · cited 1×
“Matrix-free MALDI techniques, such as SALDI (18) and DIOS (19), substitute matrix lattice for porous graphite and silicon, respectively, have higher tolerance toward detergents and salts, and do not suffer from matrix effects.”
MethodWang, Z., Gucek, M., & Hart, G. W. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806216105 · Cited by 328 · cited 1×
“New developments in top-down and quantitative proteomics could provide insights into proteotyping (231) of phosphorylation site occupancy (232) and into competition of different modifications for the same residue (233).”
BackgroundA semisynthetic epitope for kinase substrates
Allen, J. J., Li, M., Brinkworth, C. S., Paulson, J. L., Wang, D., Hübner, A., Chou, W.-H., Davis, R. J., Burlingame, A. L., Messing, R. O., et al. (2007) · Nature Methods · doi:10.1038/nmeth1048 · Cited by 327
Choe, L., D'Ascenzo, M., Relkin, N. R., Pappin, D., Ross, P., Williamson, B., Guertin, S., Pribil, P., & Lee, K. H. (2007) · PROTEOMICS · doi:10.1002/pmic.200700316 · Cited by 326 · cited 1×
“Multiplexing tagging chemistry for iTRAQ affords monitoring of four to eight samples in a single experiment (174).”
BackgroundMass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326 · cited 5×
“There are several papers that review and benchmark the performance of the Orbitrap for bottom-up (32, 33, 35, 56, 57) and top-down (58, 59) proteomic applications.”
BackgroundInfluentialSelf-citationProteomic Analysis of in Vivo Phosphorylated Synaptic Proteins
Collins, M. O., Yu, L., Coba, M. P., Husi, H., Campuzano, I., Blackstock, W. P., Choudhary, J. S., & Grant, S. G. N. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m411220200 · Cited by 320 · cited 5×
“F or p er so na l u se o nl y. MudPIT: Multidimensional Protein Identification Technology IMAC: immobilized metal affinity chromatography sensitivity due to the high capacity of strong cation-exchange (SCX) resin and the high resolution of SCX and RP.”
MethodInfluentialInterfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Hardman, M., & Makarov, A. A. (2003) · Analytical Chemistry · doi:10.1021/ac0258047 · Cited by 314
Shotgun Proteomics and Biomarker Discovery
McDonald, W. H., & Yates, J. R. (2002) · Disease Markers · doi:10.1155/2002/505397 · Cited by 314
Self-citationMcDonald, W. H., Ohi, R., Miyamoto, D. T., Mitchison, T. J., & Yates, J. R. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00563-8 · Cited by 304
Self-citationGross, J. H. (2004) · Springer eBooks · doi:10.1007/3-540-36756-x · Cited by 304
Tao, W. A., Wollscheid, B., O'Brien, R., Eng, J. K., Li, X.-J., Bodenmiller, B., Watts, J. D., Hood, L., & Aebersold, R. (2005) · Nature Methods · doi:10.1038/nmeth776 · Cited by 300 · cited 1×
“An alternative to immunopurification of phosphotyrosine peptides is dendrimer conjugation chemistry (211).”
BackgroundA Novel Proteomic Screen for Peptide-Protein Interactions
Schulze, W. X., & Mann, M. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m309909200 · Cited by 298 · cited 1×
“Quantitative pull-down assays (241) tested motif-peptides for binding to Src Homology 2 (SH2) and phosphotyrosine binding (PTB) domains.”
MethodShen, Y., Jacobs, J. M., Camp, D. G., Fang, R., Moore, R. J., Smith, R. D., Xiao, W., Davis, R. W., & Tompkins, R. G. (2004) · Analytical Chemistry · doi:10.1021/ac034869m · Cited by 297 · cited 1×
“MudPIT setup with long RP UHPLC columns has yielded higher sensitivity (low Picogram amounts) (104) and twice the protein coverage (92) compared with the conventional MudPIT setup.”
BackgroundSchnölzer, M., Jedrzejewski, P., & Lehmann, W. D. (1996) · ELECTROPHORESIS · doi:10.1002/elps.1150170517 · Cited by 295 · cited 1×
“Techniques such as ICAT (148), O18 labeling (149), and Hamon tandem mass tags (150) work best with flexible and accessible peptides.”
BackgroundIntegration with the human genome of peptide sequences obtained by high-throughput mass spectrometry
Desiere, F., Deutsch, E. W., Nesvizhskii, A. I., Mallick, P., King, N. L., Eng, J. K., Aderem, A., Boyle, R., Brunner, E., Donohoe, S., et al. (2004) · Genome Biology · doi:10.1186/gb-2004-6-1-r9 · Cited by 291
PRIDE: a public repository of protein and peptide identifications for the proteomics community
Jones, P. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj138 · Cited by 290
Comprehensive On-Line LC/LC/MS of Proteins
Opiteck, G. J., Lewis, K. C., Jorgenson, J. W., & Anderegg, R. J. (1997) · Analytical Chemistry · doi:10.1021/ac961155l · Cited by 286 · cited 1×
“One of the first 2D setups featured cation exchange chromatography coupled to a reverse phase column in line with a mass spectrometer (82) used for separation of Escherichia coli proteins.”
Method‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Shen, Y., Zhao, R., Berger, S. J., Anderson, G. A., Rodriguez, N., & Smith, R. D. (2002) · Analytical Chemistry · doi:10.1021/ac0202280 · Cited by 284 · cited 8×
“Reverse phase resins (RPLC or RP) separate compounds based on their hydrophobicity, and a significant advantage of RPLC is that the buffers used are compatible with ESI (79).”
BackgroundInfluentialTwo-Dimensional SEC/RPLC Coupled to Mass Spectrometry for the Analysis of Peptides
Opiteck, G. J., Jorgenson, J. W., & Anderegg, R. J. (1997) · Analytical Chemistry · doi:10.1021/ac961156d · Cited by 278
A Correlation Algorithm for the Automated Quantitative Analysis of Shotgun Proteomics Data
MacCoss, M. J., Wu, C. C., Liu, H., Sadygov, R., & Yates, J. R. (2003) · Analytical Chemistry · doi:10.1021/ac034790h · Cited by 278 · cited 1×
“, correlation coefficient (r)] between data points of labeled and unlabeled ion chromatograms (193).”
BackgroundSelf-citationJensen, S. S., & Larsen, M. R. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3254 · Cited by 274 · cited 1×
“The IMAC selectivity and specificity can be altered with different buffer conditions, such as pH, salt concentration (112), buffer composition, and the presence of detergents (113).”
BackgroundPhosphoprotein Analysis Using Antibodies Broadly Reactive against Phosphorylated Motifs
Zhang, H., Zha, X., Tan, Y., Hornbeck, P. V., Mastrangelo, A. J., Alessi, D. R., Polakiewicz, R. D., & Comb, M. J. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m206399200 · Cited by 270 · cited 1×
“In one application, an antibody toward the protein kinase C (PKC) recognition sequence has been used to enrich for a phosphomotif-specific subproteome (234).”
MethodHawkridge, A. M., Heublein, D. M., Bergen, H. R., Cataliotti, A., Burnett, J. C., & Muddiman, D. C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508782102 · Cited by 266 · cited 1×
“Compared with bottom-up approaches, the higher sequence coverage of top-down experiments reduces the ambiguities of the peptide-to-protein mapping, which allows for identification of the specific protein isoforms (160, 161).”
BackgroundSenko, M. W., Canterbury, J. D., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1839::aid-rcm718>3.0.co;2-v · Cited by 259 · cited 1×
“Both Orbitrap and ICR instruments use a fast Fourier transform (FFT) algorithm (55) to convert time-domain signal into mass-to-charge spectrum.”
MethodComprehensive Identification of Phosphorylation Sites in Postsynaptic Density Preparations
Trinidad, J. C., Specht, C. G., Thalhammer, A., Schoepfer, R., & Burlingame, A. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500041-mcp200 · Cited by 247 · cited 1×
“Peptide IMAC is one of the techniques for second-round enrichment of phosphopeptides, following strong cation exchange chromatography (200, 201) or protein IMAC (202, 2003); however, MOAC does not require a charging step because the metal ions are part of a solid metal bead, and consequently, material such as titanium…”
MethodMcLafferty, F. W., Horn, D. M., Breuker, K., Ge, Y., Lewis, M. A., Cerda, B., Zubarev, R. A., & Carpenter, B. K. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00223-3 · Cited by 243 · cited 1×
“This means that larger quantities of protein and higher mass accuracy instruments such as FTMS (130) and LTQ-Orbitrap (58, 66) are required to resolve isotopic envelopes of coeluting proteins.”
BackgroundAutomated de novo sequencing of proteins by tandem high-resolution mass spectrometry
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.19.10313 · Cited by 243 · cited 1×
“SILAC: stable isotope labeling with amino acids in cell culture Top-down data are usually analyzed using the expressed sequence tag (EST) method (154, 155) or the de novo method (156).”
MethodPesavento, J. J., Mizzen, C. A., & Kelleher, N. L. (2006) · Analytical Chemistry · doi:10.1021/ac0600050 · Cited by 240 · cited 1×
“Another reported advantage of the top-down approach is improved reliability of protein quantification (66, 162, 163) when protein abundances are measured directly instead of using abundances of peptides.”
BackgroundFeng, S., Ye, M., Zhou, H., Jiang, X., Jiang, X., Zou, H., & Gong, B. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t600071-mcp200 · Cited by 240 · cited 1×
“Also, other metals such as Zr4+ (114) and Ga3+ (115) are used with IMAC, yielding different specificities and improved coverage.”
MethodShen, Y., Zhang, R., Moore, R. J., Kim, J., Metz, T. O., Hixson, K. K., Zhao, R., Livesay, E. A., Udseth, H. R., & Smith, R. D. (2005) · Analytical Chemistry · doi:10.1021/ac0483062 · Cited by 230 · cited 9×
“Reverse phase resins (RPLC or RP) separate compounds based on their hydrophobicity, and a significant advantage of RPLC is that the buffers used are compatible with ESI (79).”
BackgroundInfluentialMørtz, E., O'Connor, P. B., Roepstorff, P., Kelleher, N. L., Wood, T. D., McLafferty, F. W., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.16.8264 · Cited by 220 · cited 1×
“SILAC: stable isotope labeling with amino acids in cell culture Top-down data are usually analyzed using the expressed sequence tag (EST) method (154, 155) or the de novo method (156).”
MethodLicklider, L. J., Thoreen, C. C., Peng, J., & Gygi, S. P. (2002) · Analytical Chemistry · doi:10.1021/ac025529o · Cited by 218
Absolute SILAC for Accurate Quantitation of Proteins in Complex Mixtures Down to the Attomole Level
Hanke, S., Besir, H., Oesterhelt, D., & Mann, M. (2008) · Journal of Proteome Research · doi:10.1021/pr7007175 · Cited by 216 · cited 8×
“Absolute measurements of protein concentrations can be achieved with spiked synthetic peptides (171), artificial proteins derived from detected peptides, as in QconCAT (172), and SILAC (173).”
BackgroundInfluentialMultidimensional Separations-Based Shotgun Proteomics
Fournier, M. L., Gilmore, J. M., Martin-Brown, S. A., & Washburn, M. P. (2007) · Chemical Reviews · doi:10.1021/cr068279a · Cited by 214
Anderson, D. C., Li, W., Payan, D. G., & Noble, W. S. (2003) · Journal of Proteome Research · doi:10.1021/pr0255654 · Cited by 210
The Origin of Macromolecule Ionization by Laser Irradiation (Nobel Lecture)
Tanaka, K. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200300585 · Cited by 210
Sadygov, R. G., & Yates, J. R. (2003) · Analytical Chemistry · doi:10.1021/ac034157w · Cited by 206
Self-citationSteen, H., Jebanathirajah, J. A., Springer, M., & Kirschner, M. W. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409536102 · Cited by 206
Prevention of Amino Acid Conversion in SILAC Experiments with Embryonic Stem Cells
Bendall, S. C., Hughes, C., Stewart, M. H., Doble, B., Bhatia, M., & Lajoie, G. A. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800113-mcp200 · Cited by 205
Gruhler, A., Schulze, W. X., Matthiesen, R., Mann, M., & Jensen, O. N. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500190-mcp200 · Cited by 200
Han, G., Ye, M., Zhou, H., Jiang, X., Feng, S., Jiang, X., Tian, R., Wan, D., Zou, H., & Gu, J. (2008) · PROTEOMICS · doi:10.1002/pmic.200700884 · Cited by 199 · cited 1×
“Some nonaffinity techniques such as anion-exchange chromatography (119), mixed-bed chromatography (106), and HILIC (120) offer additional strategies for enrichment.”
BackgroundMacek, B., Waanders, L. F., Olsen, J. V., & Mann, M. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500042-mcp200 · Cited by 197 · cited 16×
“F or p er so na l u se o nl y. Table 2 Approaches in mass spectrometry proteomicsa Prerequisite Advantages Drawbacks Applications Front end Analysis Top down High mass accuracy instruments High sequence coverage Precursor ion charge state limitations Single-protein characterization Ion-exchange chromatography EST LTQ-…”
BackgroundMethodInfluentialA new grammar for drug discovery
Fishman, M. C., & Porter, J. A. (2005) · Nature · doi:10.1038/437491a · Cited by 193 · cited 2×
“Intracellular molecular signaling pathways represent one such set of rules (247).”
BackgroundMultidimensional Separations for Protein/Peptide Analysis in the Post-Genomic Era
Liu, H., Lin, D., & Yates, J. R. (2002) · BioTechniques · doi:10.2144/02324pt01 · Cited by 188 · cited 1×
“Another common way to address limited peak capacity (94, 95) is to integrate RPLC as part of a multidimensional separation approach.”
BackgroundSelf-citationPhosphoPep—a phosphoproteome resource for systems biology research in Drosophila Kc167 cells
Bodenmiller, B., Malmstrom, J., Gerrits, B., Campbell, D., Lam, H., Schmidt, A., Rinner, O., Mueller, L. N., Shannon, P. T., Pedrioli, P. G., et al. (2007) · Molecular Systems Biology · doi:10.1038/msb4100182 · Cited by 187 · cited 2×
“Comparison of IMAC, MOAC, and phosphoramidate chemistry methods highlights the complementary nature of enrichment (199).”
MethodA high confidence, manually validated human blood plasma protein reference set
Schenk, S., Schoenhals, G. J., de Souza, G., & Mann, M. (2008) · BMC Medical Genomics · doi:10.1186/1755-8794-1-41 · Cited by 181 · cited 1×
“Some of the recent applications of the LTQ-Orbitrap highlight the benefits of high mass accuracy: It improves quantification of low-abundance peptides with S/N ratio of 10 (60), it aids in profiling very complex biological samples such as human plasma (61), and it furthers identification of proteins from the limited s…”
Performance of a Linear Ion Trap-Orbitrap Hybrid for Peptide Analysis
Yates, J. R., Cociorva, D., Liao, L., & Zabrouskov, V. (2006) · Analytical Chemistry · doi:10.1021/ac0514624 · Cited by 175 · cited 1×
“There are several papers that review and benchmark the performance of the Orbitrap for bottom-up (32, 33, 35, 56, 57) and top-down (58, 59) proteomic applications.”
BackgroundSelf-citationProteomics based on high-efficiency capillary separations
Shen, Y., & Smith, R. D. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200209)23:18<3106::aid-elps3106>3.0.co;2-y · Cited by 172 · cited 2×
“Reverse phase resins (RPLC or RP) separate compounds based on their hydrophobicity, and a significant advantage of RPLC is that the buffers used are compatible with ESI (79).”
BackgroundMethodMcLafferty, F. W., Fridriksson, E. K., Horn, D. M., Lewis, M. A., & Zubarev, R. A. (1999) · Science · doi:10.1126/science.284.5418.1289 · Cited by 166
Motoyama, A., Xu, T., Ruse, C. I., Wohlschlegel, J. A., & Yates, J. R. (2007) · Analytical Chemistry · doi:10.1021/ac062292d · Cited by 166 · cited 2×
“Other materials used as first dimension (1D) are size exclusion (97), anion-exchange, (105) and a mixed-bed approach (106).”
BackgroundSelf-citationThe need for a public proteomics repository
Prince, J. T., Carlson, M. W., Wang, R., Lu, P., & Marcotte, E. M. (2004) · Nature Biotechnology · doi:10.1038/nbt0404-471 · Cited by 164
Advances in the Analysis of Protein Phosphorylation
Paradela, A., & Albar, J. P. (2008) · Journal of Proteome Research · doi:10.1021/pr7006544 · Cited by 164 · cited 2×
“Most bottom-up applications require tandem data acquisition in which peptides are subjected to collision-activated dissociation (CAD or CID).”
BackgroundA second-site suppressor strategy for chemical genetic analysis of diverse protein kinases
Zhang, C., Kenski, D. M., Paulson, J., Bonshtien, A., Sessa, G., Cross, J. V., Templeton, D. J., & Shokat, K. M. (2005) · Nature Methods · doi:10.1038/nmeth764 · Cited by 160 · cited 1×
“Currently, a repertoire of 40 AS kinases exists, and it is estimated that most kinases can be engineered in AS alleles (246).”
BackgroundA new linear ion trap time-of-flight system with tandem mass spectrometry capabilities
Campbell, J. M., Collings, B. A., & Douglas, D. J. (1998) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19981030)12:20<1463::aid-rcm357>3.0.co;2-h · Cited by 158
Origin and number of charges observed on multiply-protonated native proteins produced by ESI
Felitsyn, N. M., Peschke, M., & Kebarle, P. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00588-2 · Cited by 157
Yue, G., Luo, Q., Zhang, J., Wu, S.-L., & Karger, B. L. (2007) · Analytical Chemistry · doi:10.1021/ac061411m · Cited by 156 · cited 1×
“Enzymatic release from a solid support combined with H18O enzymatic labeling led to the development of IGOT, the isotope-coded glycosylation site–specific tagging (123, 124).”
BackgroundAccurate Inclusion Mass Screening
Jaffe, J. D., Keshishian, H., Chang, B., Addona, T. A., Gillette, M. A., & Carr, S. A. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800218-mcp200 · Cited by 154
iTRAQ Reagent-Based Quantitative Proteomic Analysis on a Linear Ion Trap Mass Spectrometer
Griffin, T. J., Xie, H., Bandhakavi, S., Popko, J., Mohan, A., Carlis, J. V., & Higgins, L. (2007) · Journal of Proteome Research · doi:10.1021/pr070291b · Cited by 152 · cited 1×
“Introduction of pulsed Q dissociation (PQD) (177) in the ion trap facilitates detection of iTRAQ reporter ions, bridging the gap between the linear ion trap with PQD and a quadrupole TOF instrument (178).”
BackgroundZhou, H., Tian, R., Ye, M., Xu, S., Feng, S., Pan, C., Jiang, X., Li, X., & Zou, H. (2007) · Electrophoresis · doi:10.1002/elps.200600718 · Cited by 148 · cited 1×
“Other metal oxide affinity resins are TiO2 (116), Fe3O4 (117), and ZrO2 (118).”
BackgroundSignature-peptide approach to detecting proteins in complex mixtures
Geng, M., Ji, J. A., & Regnier, F. E. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00951-6 · Cited by 147 · cited 1×
“Another affinity enrichment method of N-linked glycopeptides involves immobilized lectin binding site chemistry (122).”
MethodCombining Protein-Based IMAC, Peptide-Based IMAC, and MudPIT for Efficient Phosphoproteomic Analysis
Cantin, G. T., Yi, W., Lu, B., Park, S. K., Xu, T., Lee, J.-D., & Yates, J. R. (2008) · Journal of Proteome Research · doi:10.1021/pr0705441 · Cited by 145
Self-citationA new linear ion trap time-of-flight system with tandem mass spectrometry capabilities
Campbell, J. M., Collings, B. A., & Douglas, D. J. (1998) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19981030)12:20<1457::aid-rcm346>3.0.co;2-a · Cited by 144
Top-down identification and characterization of biomolecules by mass spectrometry
Breuker, K., Jin, M., Han, X., Jiang, H., & McLafferty, F. W. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.05.013 · Cited by 141 · cited 1×
“Although the LTQ-Orbitrap is used in top-down experiments (58, 66), one of the FTICR benefits is broader mass-to-charge range, which is best suited for top-down protein analysis and has the ability to carry out gas-phase reactions in the ICR cell (45, 67).”
MethodWang, X., Stoll, D. R., Schellinger, A. P., & Carr, P. W. (2006) · Analytical Chemistry · doi:10.1021/ac0600149 · Cited by 141 · cited 1×
“Significant effort goes into increasing peak capacity (83), sensitivity (84, 85), reproducibility, and analysis speed of reverse phase chromatography (86, 87).”
BackgroundLi, Y., Xu, X., Qi, D., Deng, C., Yang, P., & Zhang, X. (2008) · Journal of Proteome Research · doi:10.1021/pr700582z · Cited by 139 · cited 1×
“Other metal oxide affinity resins are TiO2 (116), Fe3O4 (117), and ZrO2 (118).”
BackgroundPhosphoproteomics by mass spectrometry and classical protein chemistry approaches
Salih, E. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.20042 · Cited by 139
Differential proteomics: An overview of gel and non-gel based approaches
Monteoliva, L., & Albar, J. P. (2004) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/3.3.220 · Cited by 137
Motoyama, A., Venable, J. D., Ruse, C. I., & Yates, J. R. (2006) · Analytical Chemistry · doi:10.1021/ac060354u · Cited by 136 · cited 9×
“HPLC has become a standard front end for many biological applications and gave rise to several LC/MS setups (33, 37, 77).”
BackgroundResultInfluentialSelf-citationStoll, D. R., Wang, X., & Carr, P. W. (2007) · Analytical Chemistry · doi:10.1021/ac701676b · Cited by 136 · cited 1×
“Although there are recent review papers that cover historical and theoretical aspects of multidimensional separation (77, 99), we mention some of the milestones in addition to the current trends.”
BackgroundHoof, D. V., Pinkse, M. W. H., Oostwaard, D. W., Mummery, C. L., Heck, A. J. R., & Krijgsveld, J. (2007) · Nature Methods · doi:10.1038/nmeth0907-677 · Cited by 133
Bio-orthogonal Affinity Purification of Direct Kinase Substrates
Allen, J. J., Lazerwith, S. E., & Shokat, K. M. (2005) · Journal of the American Chemical Society · doi:10.1021/ja050727t · Cited by 131 · cited 1×
“One such example is the engineering of analog-specific (AS) kinase alleles that use ATP-γ -S, resulting in thiophosphorylation of protein substrates (244).”
BackgroundComparison of Two-Dimensional Fractionation Techniques for Shotgun Proteomics
Dowell, J. A., Frost, D. C., Zhang, J., & Li, L. (2008) · Analytical Chemistry · doi:10.1021/ac8007994 · Cited by 130 · cited 1×
“Recent work compares several 1D methods (107) within the 2D setup to separate proteins of various physicochemical properties.”
Tsai, C.-F., Wang, Y.-T., Chen, Y.-R., Lai, C.-Y., Lin, P.-Y., Pan, K.-T., Chen, J.-Y., Khoo, K.-H., & Chen, Y.-J. (2008) · Journal of Proteome Research · doi:10.1021/pr800364d · Cited by 129 · cited 1×
“The IMAC selectivity and specificity can be altered with different buffer conditions, such as pH, salt concentration (112), buffer composition, and the presence of detergents (113).”
BackgroundHolland, L. A., & Jorgenson, J. W. (1995) · Analytical Chemistry · doi:10.1021/ac00114a026 · Cited by 128 · cited 1×
“Other materials used as first dimension (1D) are size exclusion (97), anion-exchange, (105) and a mixed-bed approach (106).”
BackgroundTwo-dimensional electrophoresis of membrane proteins
Braun, R. J., Kinkl, N., Beer, M., & Ueffing, M. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1514-6 · Cited by 126
Bakalarski, C. E., Elias, J. E., Villén, J., Haas, W., Gerber, S. A., Everley, P. A., & Gygi, S. P. (2008) · Journal of Proteome Research · doi:10.1021/pr800333e · Cited by 125 · cited 1×
“Some of the recent applications of the LTQ-Orbitrap highlight the benefits of high mass accuracy: It improves quantification of low-abundance peptides with S/N ratio of 10 (60), it aids in profiling very complex biological samples such as human plasma (61), and it furthers identification of proteins from the limited s…”
BackgroundMayya, V., Rezual, K., Wu, L., Fong, M. B., & Han, D. K. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500029-mcp200 · Cited by 124 · cited 1×
“An AbsoluteQUAntification (AQUA)-based approach quantified inhibitory phosphorylation of adjacent sites of cyclin-dependent kinases (224).”
MethodA combined linear ion trap time‐of‐flight system with improved performance and MS n capabilities
Collings, B. A., Campbell, J. M., Mao, D., & Douglas, D. J. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.440 · Cited by 124
Chen, Y., Shiea, J., & Sunner, J. A. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00726-2 · Cited by 123 · cited 1×
“Matrix-free MALDI techniques, such as SALDI (18) and DIOS (19), substitute matrix lattice for porous graphite and silicon, respectively, have higher tolerance toward detergents and salts, and do not suffer from matrix effects.”
MethodStable Isotopic Labeling by Amino Acids in Cultured Primary Neurons
Spellman, D. S., Deinhardt, K., Darie, C. C., Chao, M. V., & Neubert, T. A. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700387-mcp200 · Cited by 121 · cited 1×
“Recently, SILAC has been applied to labeling of primary cells (184) and mice (185).”
MethodKay, R. G., Gregory, B., Grace, P. B., & Pleasance, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3130 · Cited by 119 · cited 1×
“A recent comparison of regular HPLC with sub-2-μm-particle UPLC using human plasma samples highlighted improved resolution, sensitivity, and analysis time reduction (93).”
BackgroundEckerskorn, C., Strupat, K., Karas, M., Hillenkamp, F., & Lottspeich, F. (1992) · Electrophoresis · doi:10.1002/elps.11501301140 · Cited by 118 · cited 1×
“Gel-based methods have been traditionally used with pulsed ionization MALDI instruments in which the protein band can be excised, digested, and off-line sampled with MALDI source (76).”
MethodZabrouskov, V., Ge, Y., Schwartz, J., & Walker, J. W. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700524-mcp200 · Cited by 117 · cited 1×
“New developments in top-down and quantitative proteomics could provide insights into proteotyping (231) of phosphorylation site occupancy (232) and into competition of different modifications for the same residue (233).”
BackgroundSadygov, R. G., Martín-Maroto, F., & Hühmer, A. F. R. (2006) · Analytical Chemistry · doi:10.1021/ac060923y · Cited by 116
Shotgun proteomics: integrating technologies to answer biological questions.
McDonald, W. H., & Yates, J. R. (2003) · PubMed · Cited by 114
Self-citationDevelopment of phosphopeptide enrichment techniques for phosphoproteome analysis
Han, G., Ye, M., & Zou, H. (2008) · The Analyst · doi:10.1039/b806775a · Cited by 114 · cited 1×
“In addition to chromatographic methods, the antibodies against phosphoamino acid epitopes, magnetic materials, and nanoparticles (197) as well as metal ionphosphopeptide precipitations are part of the toolbox for the affinity-based enrichment of phosphopeptides.”
BackgroundWhat place for polyacrylamide in proteomics?
Herbert, B. R., Harry, J. L., Packer, N. H., Gooley, A. A., Pedersen, S. K., & Williams, K. L. (2001) · Trends in biotechnology · doi:10.1016/s0167-7799(01)01796-6 · Cited by 112
Advances in Proteomic Technologies
Yarmush, M. L., & Jayaraman, A. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153443 · Cited by 112 · cited 1×
“This third downstream “omics” of science is known as proteomics (7), and it studies the protein complement of cells, including identification, modification, quantification, and localization.”
BackgroundNeusüß, C., Pelzing, M., & Macht, M. (2002) · Electrophoresis · doi:10.1002/1522-2683(200209)23:18<3224::aid-elps3224>3.0.co;2-# · Cited by 110
Ibarrola, N., Molina, H., Iwahori, A., & Pandey, A. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m311714200 · Cited by 105 · cited 2×
“Distinct labeling of phosphorylation sites can be achieved through either Tyr-SILAC (181) or γ [(18)O4]-ATP (226).”
BackgroundMethodAccurate Mass Measurements in Proteomics
Liu, T., Belov, M. E., Jaitly, N., Qian, W.-J., & Smith, R. D. (2007) · Chemical Reviews · doi:10.1021/cr068288j · Cited by 104
Hager, J. W., & Blanc, J. C. Y. L. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00426-6 · Cited by 104 · cited 1×
“The following instrument configurations are the most widely used solutions in the field of proteomics: ion traps [QIT: three-dimensional (3D) ion trap, LIT: linear ion trap] (38), triple quadrupoles (TQ), LTQ-Orbitrap (39–42) hybrid instrument (Thermo Scientific), LTQFTICR (43–46) (Thermo Scientific), and the TQ-FTICR…”
Method
Research works printed but not linked: 7
- Yarmush ML, 2002, Annu. Rev., 4, 349
- Ruse CI, 2007, Systems Biology, 3
- 10.1002/(sici)1522-2683(20000401)21:6<1164::aid-elps1164>3.3.co;2-s · doi:10.1002/(sici)1522-2683(20000401)21:6<1164::aid-elps1164>3.3.co;2-s
- 30. de Hoffman E, Stroobant V. 2007.Mass Spectrometry. Wiley. 489pp.
- 10.1002/(sici)1097-0231(19960610)10:8<889::aid-rcm615>3.3.co;2-6 · doi:10.1002/(sici)1097-0231(19960610)10:8<889::aid-rcm615>3.3.co;2-6
- McDonald WH, 2003, Curr. Opin. Mol. Ther., 5, 302
- 177. Schwartz J, Syka JP, Quarmby ST. 2005.Improving the fundamentals of MSnon 2D ion traps: new ion activation and isolation techniques. Presented at ASMS Conf. on Mass Spectrom., 53rd, San Antonio
Cited by
DIA-NN: neural networks and interference correction enable deep proteome coverage in high throughput
Demichev, V., Messner, C. B., Vernardis, S. I., Lilley, K. S., & Ralser, M. (2020) · Nature Methods · doi:10.1038/s41592-019-0638-x · Cited by 3,343
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationBioaerosols in the Earth system: Climate, health, and ecosystem interactions
Fröhlich-Nowoisky, J., Kampf, C. J., Weber, B., Huffman, J. A., Pöhlker, C., Andreae, M. O., Lang-Yona, N., Burrows, S. M., Gunthe, S. S., Elbert, W., et al. (2016) · Atmospheric Research · doi:10.1016/j.atmosres.2016.07.018 · Cited by 1,007
A Parsimony Approach to Biological Pathway Reconstruction/Inference for Genomes and Metagenomes
Ye, Y., & Doak, T. G. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000465 · Cited by 686
“. Metagenomic profiling data can be viewed as a sampling of the genomic sequences from many kinds of microbes living in a specific environment. Again, the incompleteness of the data makes it difficult to reconstruct the entire pathways encoded by a metagenome. Nevertheless, it is becoming routine to “reconstruct” path…”
BackgroundZhou, B., Xiao, J. F., Tuli, L., & Ressom, H. W. (2011) · Molecular BioSystems · doi:10.1039/c1mb05350g · Cited by 639
Metadata
- Authors
- Yates, J. R., Ruse, C. I., & Nakorchevsky, A.
- Affiliations
- Scripps Research Institute (US)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 49-79
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2140985419
- Cited by
- 1,078
- References
- 256
- Citations by year
- 2026: 19 · 2025: 27 · 2024: 35 · 2023: 28 · 2022: 49 · 2021: 43 · 2020: 41 · 2019: 66 · 2018: 58 · 2017: 61 · 2016: 52 · 2015: 97 · 2014: 90 · 2013: 111 · 2012: 114
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- mass spectrometry-based proteomics, MudPIT, quantitative phosphoproteomics, phosphopeptide enrichment, beta-adrenergic signaling, UPLC, chromatographic separation, experimental design
- MeSH terms
- Animals, Humans, Peptides, Phosphorylation, Proteins, Receptors, Adrenergic, beta, Software, Mass Spectrometry, Reproducibility of Results, Signal Transduction, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Computational Biology, Spectrometry, Mass, Electrospray Ionization, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.