The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Measuring agreement in method comparison studies
Abstract
Agreement between two methods of clinical measurement can be quantified using the differences between observations made using the two methods on the same subjects. The 95% limits of agreement, estimated by mean difference 1.96 standard deviation of the differences, provide an interval within which 95% of differences between measurements by the two methods are expected to lie. We describe how graphical methods can be used to investigate the assumptions of the method and we also give confidence intervals. We extend the basic approach to data where there is a relationship between difference and magnitude, both with a simple logarithmic transformation approach and a new, more general, regression approach. We discuss the importance of the repeatability of each method separately and compare an estimate of this to the limits of agreement. We extend the limits of agreement approach to data with repeated measurements, proposing new estimates for equal numbers of replicates by each method on each subject, for unequal numbers of replicates, and for replicated data collected in pairs, where the underlying value of the quantity being measured is changing. Finally, we describe a nonparametric approach to comparing methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For the calculations, the mean of the Moxy passive trials was used against the corresponding active trial and therefore proper adjustments to SD were made as proposed by Bland and Altman.40”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [40]
In the citing paper
“The variance for single differences between pairs of measurements on different subject is found by summing the between subjects and within subjects variances (Bland and Altman 1999).”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Bland and Altman 1999
In the citing paper
“(In our earlier paper (Bland and Altman 1999), we incorrectly stated that this number should be used to multiply the difference in the sum of squares, rather than divide it.)”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Bland and Altman 1999
In the citing paper
“It is valuable, however, to obtain replicate measurements by each method on each individual so that the repeatability of the two methods can be compared (Bland and Altman 1999).”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Bland and Altman 1999
In the citing paper
“Although these have been described previously (Bland and Altman 1999) no numerical example was given for the case when the true value of the quantity being measured varied and also there was an error in the mathematical description.”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Bland and Altman 1999
In the citing paper
“As described in section 5 in Bland and Altman (1999), we derive the estimated standard deviation for individual differences from the variance of the subject mean differences and an extra term derived from the separate measurement error of each method.”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Bland and Altman (1999)
In the citing paper
“Bland–Altman comparisons reported good agreement for LLR vs. Navlit and Navopt, with > 95% and > 91.8% of measurements within the limits of agreement across all CPAK parameters, respectively.”
From Imageless robotic total knee arthroplasty determines similar coronal plane alignment of the knee (CPAK) parameters to long leg radiographs (2024) · cites this paper as [31]
In the citing paper
“Bland–Altman comparisons reported good agreement for LLR vs. Navlit and Navopt, with > 95% and > 91.8% of measurements within the limits of agreement across all CPAK parameters, respectively.”
From Imageless robotic total knee arthroplasty determines similar coronal plane alignment of the knee (CPAK) parameters to long leg radiographs (2024) · cites this paper as [31]
In the citing paper
“Current research into the HR accuracy of wrist-worn wearable devices attempt to compare the measurement between wearable PPG and a reference method, such as an ECG, in order to determine whether or not measurements between the devices are outside of clinically important limits of agreement, so that devices can supplement, eventually replace, or be used interchangeably37,38.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [37]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Self-citationMeasurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationComparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Self-citationClinical assessment of gestational age in the newborn infant
Dubowitz, L. M. S., Dubowitz, V., & Goldberg, C. (1970) · The Journal of Pediatrics · doi:10.1016/s0022-3476(70)80038-5 · Cited by 2,230
Searle, S. R., Casella, G., & McCulloch, C. E. (1992) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316856 · Cited by 1,926
The Journal of Laboratory and Clinical Medicine
(2003) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(03)00127-6 · Cited by 1,803
International Journal of Methods in Psychiatric Research
Bhugra, D., Bhui, K. S., Desai, M., Singh, J., & Baldwin, D. (2006) · International Journal of Methods in Psychiatric Research · doi:10.1002/(issn)1557-0657 · Cited by 1,492
Bland, M., & Altman, D. G. (1990) · Computers in Biology and Medicine · doi:10.1016/0010-4825(90)90013-f · Cited by 689
Self-citationSPECIAL ARTICLE COMPARING METHODS OF MEASUREMENT
Ludbrook, J. (1997) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1997.tb01807.x · Cited by 363
Confidence Intervals on Variance Components
Burdick (1992) · CRC Press eBooks · doi:10.1201/9781482277142 · Cited by 351
Research works printed but not linked: 2
- O'Brien E, 1993, Journal of Hypertension, 11, S43
- Altman DG, 1987, Applied Statistics, 36, 224
Cited by
Sorted by citations
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,022
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 1,864
Self-citationDevelopment, validation and utilisation of food-frequency questionnaires – a review
Cade, J., Thompson, R., Burley, V., & Warm, D. (2002) · Public Health Nutrition · doi:10.1079/phn2001318 · Cited by 1,423
Marino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056
Interrater agreement and interrater reliability: Key concepts, approaches, and applications
Gisev, N., Bell, J. S., & Chen, T. F. (2013) · Research in Social and Administrative Pharmacy · doi:10.1016/j.sapharm.2012.04.004 · Cited by 924
Analysis of the Accuracy and Robustness of the Leap Motion Controller
Weichert, F., Bachmann, D., Rudak, B., & Fisseler, D. (2013) · Sensors · doi:10.3390/s130506380 · Cited by 913
The new AASM criteria for scoring hypopneas: impact on the apnea hypopnea index
Ruehland, W. R., Rochford, P. D., O’Donoghue, F. J., Pierce, R. J., Singh, P., & Thornton, A. T. (2009) · SLEEP · doi:10.1093/sleep/32.2.150 · Cited by 696
Warren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Wang, C., Catlin, D. H., Demers, L. M., Starcevic, B., & Swerdloff, R. S. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031287 · Cited by 580
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Food-frequency questionnaires: a review of their design, validation and utilisation
Cade, J. E., Burley, V. J., Warm, D. L., Thompson, R. L., & Margetts, B. M. (2004) · Nutrition Research Reviews · doi:10.1079/nrr200370 · Cited by 518
Celis-Morales, C. A., Perez-Bravo, F., Ibañez, L., Salas, C., Bailey, M. E. S., & Gill, J. M. R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0036345 · Cited by 486
McAlinden, C., Khadka, J., & Pesudovs, K. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00851.x · Cited by 436
Li, X., Dunn, J., Salins, D., Zhou, G., Zhou, W., Schüssler-Fiorenza Rose, S. M., Perelman, D., Colbert, E., Runge, R., Rego, S., et al. (2017) · PLOS Biology · doi:10.1371/journal.pbio.2001402 · Cited by 431
Short-term variability in measures of glycemia and implications for the classification of diabetes
Selvin, E. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.14.1545 · Cited by 402
Diarrhoea-predominant IBS patients show mast cell activation and hyperplasia in the jejunum
Guilarte, M., Santos, J., de Torres, I., Alonso, C., Vicario, M., Ramos, L., Martinez, C., Casellas, F., Saperas, E., & Malagelada, J. R. (2007) · Gut · doi:10.1136/gut.2006.100594 · Cited by 385
Palmqvist, S., Zetterberg, H., Blennow, K., Vestberg, S., Andreasson, U., Brooks, D. J., Owenius, R., Hägerström, D., Wollmer, P., Minthon, L., et al. (2014) · JAMA Neurology · doi:10.1001/jamaneurol.2014.1358 · Cited by 368
Cecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351
Schaffarczyk, M., Rogers, B., Reer, R., & Gronwald, T. (2022) · Sensors · doi:10.3390/s22176536 · Cited by 349
Influence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Test-retest reliability of evoked BOLD signals from a cognitive-emotive fMRI test battery.
Plichta, M. M., Schwarz, A. J., Grimm, O., Morgen, K., Mier, D., Haddad, L., Gerdes, A. B. M., Sauer, C., Tost, H., Esslinger, C., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.129 · Cited by 287
Nelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310
Thermal Indices and Thermophysiological Modeling for Heat Stress
Havenith, G., & Fiala, D. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140051 · Cited by 262
Rafi, Z., & Greenland, S. (2020) · BMC Medical Research Methodology · doi:10.1186/s12874-020-01105-9 · Cited by 243
Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research
Nelson, B. W., Low, C. A., Jacobson, N., Areán, P., Torous, J., & Allen, N. B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0297-4 · Cited by 241
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
Detection of anaemia from retinal fundus images via deep learning
Mitani, A., Huang, A., Venugopalan, S., Corrado, G. S., Peng, L., Webster, D. R., Hammel, N., Liu, Y., & Varadarajan, A. V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0487-z · Cited by 230
A Primer on the Use of Equivalence Testing for Evaluating Measurement Agreement
DIXON, P. M., SAINT-MAURICE, P. F., KIM, Y., HIBBING, P., BAI, Y., & WELK, G. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001481 · Cited by 227
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224
Repeatability of SUV in Oncologic 18F-FDG PET
Lodge, M. A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.186353 · Cited by 214
Janzen, N., Peter, M., Sander, S., Steuerwald, U., Terhardt, M., Holtkamp, U., & Sander, J. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-2890 · Cited by 211
Simonsick, E. M., Fan, E., & Fleg, J. L. (2006) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.00530.x · Cited by 199
Accurate Determination of Energy Needs in Hospitalized Patients
Boullata, J., Williams, J., Cottrell, F., Hudson, L., & Compher, C. (2007) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.12.014 · Cited by 201
Piche, T., Saint-Paul, M. C., Dainese, R., Marine-Barjoan, E., Iannelli, A., Montoya, M. L., Peyron, J. F., Czerucka, D., Cherikh, F., Filippi, J., et al. (2008) · Gut · doi:10.1136/gut.2007.127068 · Cited by 198
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Novel quantitative phenotypes of exercise training in mouse models
De Bono, J. P., Adlam, D., Paterson, D. J., & Channon, K. M. (2006) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00694.2005 · Cited by 197
Correlation of serum allergy (IgE) tests performed by different assay systems
Wang, J., Godbold, J. H., & Sampson, H. A. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.12.1150 · Cited by 188
Surveillance for ocular hypertension: an evidence synthesis and economic evaluation.
Burr, J., Botello-Pinzon, P., Takwoingi, Y., Hernández, R., Vazquez-Montes, M., Elders, A., Asaoka, R., Banister, K., van der Schoot, J., Fraser, C., et al. (2012) · Health Technology Assessment · doi:10.3310/hta16290 · Cited by 180
Validity and reliability of ventilatory and blood lactate thresholds in well-trained cyclists
Pallarés, J. G., Morán-Navarro, R., Ortega, J. F., Fernández-Elías, V. E., & Mora-Rodriguez, R. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163389 · Cited by 180
Tully, M. A., McBride, C., Heron, L., & Hunter, R. F. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-952 · Cited by 172
Pack, A., Barrett, A., & Escalante, J. (2024) · Computers and Education: Artificial Intelligence · doi:10.1016/j.caeai.2024.100234 · Cited by 166
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 159
“For the calculations, the mean of the Moxy passive trials was used against the corresponding active trial and therefore proper adjustments to SD were made as proposed by Bland and Altman.40 2.5.3 Face validity: 0% to 100% scale To determine face validity, a comparison was made between SmO2 results from the AOM passive…”
MethodInfluentialStressing the accuracy: Wrist‐worn wearable sensor validation over different conditions
Menghini, L., Gianfranchi, E., Cellini, N., Patron, E., Tagliabue, M., & Sarlo, M. (2019) · Psychophysiology · doi:10.1111/psyp.13441 · Cited by 157
Ilyas, H., Mikhaeel, N. G., Dunn, J. T., Rahman, F., Møller, H., Smith, D., & Barrington, S. F. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3953-z · Cited by 150
Assessment of the Fitbit Charge 2 for monitoring heart rate
Benedetto, S., Caldato, C., Bazzan, E., Greenwood, D. C., Pensabene, V., & Actis, P. (2018) · PLOS ONE · doi:10.1371/journal.pone.0192691 · Cited by 149
Measuring physical activity during pregnancy
Harrison, C. L., Thompson, R. G., Teede, H. J., & Lombard, C. B. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-19 · Cited by 139
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134
“We described agreement between the two DPA measurements with Bland-Altman plots [36,37].”
Thompson, D., Batterham, A. M., Bock, S., Robson, C., & Stokes, K. (2006) · The Journal of Nutrition · doi:10.1093/jn/136.4.1037 · Cited by 129
Accuracy of a PDA-based dietary assessment program
Beasley, J., Riley, W. T., & Jean-Mary, J. (2005) · Nutrition · doi:10.1016/j.nut.2004.11.006 · Cited by 124
Teufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0213064 · Cited by 129
A non-invasive device to continuously determine heat strain in humans
Gunga, H.-C., Sandsund, M., Reinertsen, R. E., Sattler, F., & Koch, J. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.03.004 · Cited by 129
Valbuena, V. S. M., Seelye, S., Sjoding, M. W., Valley, T. S., Dickson, R. P., Gay, S. E., Claar, D., Prescott, H. C., & Iwashyna, T. J. (2022) · BMJ · doi:10.1136/bmj-2021-069775 · Cited by 127
Protocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124
Gunga, H.-C., Werner, A., Stahn, A., Steinach, M., Schlabs, T., Koralewski, E., Kunz, D., Belavý, D. L., Felsenberg, D., Sattler, F., et al. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.04.005 · Cited by 122
Mulder, E. R., de Jong, R. A., Knol, D. L., van Schijndel, R. A., Cover, K. S., Visser, P. J., Barkhof, F., & Vrenken, H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.058 · Cited by 122
Day-to-day variability in spot urine albumin-creatinine ratio
Naresh, C. N., Hayen, A., Weening, A., Craig, J. C., & Chadban, S. J. (2013) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2013.06.016 · Cited by 107
Drawz, P. E., Agarwal, A., Dwyer, J. P., Horwitz, E., Lash, J., Lenoir, K., McWilliams, A., Oparil, S., Rahbari-Oskoui, F., Rahman, M., et al. (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.5028 · Cited by 105
Jacobs, E. M. G., Hendriks, J. C. M., van Tits, B. L. J. H., Evans, P. J., Breuer, W., Liu, D. Y., Jansen, E. H. J. M., Jauhiainen, K., Sturm, B., Porter, J. B., et al. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.03.008 · Cited by 101
Farah, N. M., Saw Yee, T., & Mohd Rasdi, H. F. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16234750 · Cited by 99
Mortensen, K. H., Hjerrild, B. E., Stochholm, K., Andersen, N. H., Sørensen, K. E., Lundorf, E., Hørlyck, A., Pedersen, E. M., Christiansen, J. S., & Gravholt, C. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-24 · Cited by 99
Reproducibility and repeatability of MRI‐based body composition analysis
Borga, M., Ahlgren, A., Romu, T., Widholm, P., Dahlqvist Leinhard, O., & West, J. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28360 · Cited by 94
Ball, T. J., Joy, E. A., Gren, L. H., & Shaw, J. M. (2016) · Preventing Chronic Disease · doi:10.5888/pcd13.150228 · Cited by 89
Venema, L. F., Post, W. J., Hendriks, H. G., Huet, R. C., de Wolf, J. T., & de Vries, A. J. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e368bc · Cited by 92
Measurement of blood glucose: comparison between different types of specimens
Carstensen, B., Lindström, J., Sundvall, J., Borch-Johnsen, K., & Tuomilehto, J. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2007.006212 · Cited by 88
Hanggi, M. P., Teuscher, U. M., Roos, M., & Peltomaki, T. A. (2008) · The European Journal of Orthodontics · doi:10.1093/ejo/cjn055 · Cited by 85
Assessment of ACTH assay variability: a multicenter study
Pecori Giraldi, F., Saccani, A., Cavagnini, F., & _, _. (2011) · European Journal of Endocrinology · doi:10.1530/eje-10-0962 · Cited by 80
Stöckl, D., Rodríguez Cabaleiro, D., Van Uytfanghe, K., & Thienpont, L. M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.036095 · Cited by 79
ADHD in Swedish 3- to 7-year-old children
KADESJÖ, C., KADESJÖ, B., HÄGGLÖF, B., & GILLBERG, C. (2001) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/00004583-200109000-00010 · Cited by 72
Roski, F., Hammel, J., Mei, K., Baum, T., Kirschke, J. S., Laugerette, A., Kopp, F. K., Bodden, J., Pfeiffer, D., Pfeiffer, F., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06263-z · Cited by 70
Short-term venous stasis influences routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000178828.59866.03 · Cited by 66
Tractenberg, R. E., Jonklaas, J., & Soldin, S. J. (2010) · International Journal of Analytical Chemistry · doi:10.1155/2010/234808 · Cited by 64
Gonzales, T. I., Westgate, K., Strain, T., Hollidge, S., Jeon, J., Christensen, D. L., Jensen, J., Wareham, N. J., & Brage, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-94768-3 · Cited by 59
Yu, S., Powell, A., Khow, K., & Visvanathan, R. (2016) · Nutrients · doi:10.3390/nu8040189 · Cited by 58
Rogers, B., Giles, D., Draper, N., Mourot, L., & Gronwald, T. (2021) · Sensors · doi:10.3390/s21030821 · Cited by 54
Spineli, L. M. (2019) · BMC Medical Research Methodology · doi:10.1186/s12874-019-0731-y · Cited by 47
Awadh, A. M. A., Prefumo, F., Bland, J. M., & Carvalho, J. S. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2813 · Cited by 50
Self-citationPecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“96 times the standard deviation (SD) of these differences (random error), which are the two components of the 95% coefficient of reproducibility [14].”
A new simple technique for 3-dimensional sonographic assessment of the pelvic floor muscles
Youssef, A., Montaguti, E., Sanlorenzo, O., Cariello, L., Awad, E. E., Pacella, G., Ghi, T., Pilu, G., & Rizzo, N. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.1.65 · Cited by 48
Riley, L. E., Chen, G. J., & Latham, H. E. (2017) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000258 · Cited by 43
Bilo, G., Sala, O., Perego, C., Faini, A., Gao, L., Głuszewska, A., Ochoa, J. E., Pellegrini, D., Lonati, L. M., & Parati, G. (2017) · Hypertension Research · doi:10.1038/hr.2016.184 · Cited by 43
An evaluation of two capillary sample collection kits for laboratory measurement of HbA1c
Beck, R. W., Bocchino, L. E., Lum, J. W., Kollman, C., Barnes-Lomen, V., Sulik, M., Haller, M. J., Bode, B., Cernich, J. T., Killeen, A. A., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0023 · Cited by 42
Rogers, B., Schaffarczyk, M., Clauß, M., Mourot, L., & Gronwald, T. (2022) · Sensors · doi:10.3390/s22052032 · Cited by 41
Using photoplethysmography in heart rate monitoring of patients with epilepsy
van Andel, J., Ungureanu, C., Aarts, R., Leijten, F., & Arends, J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.02.018 · Cited by 39
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Chronobiology International · doi:10.1080/07420528.2019.1679826 · Cited by 38
Lee, Q. Y., Redmond, S. J., Chan, G. S., Middleton, P. M., Steel, E., Malouf, P., Critoph, C., Flynn, G., O’Lone, E., & Lovell, N. H. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-19 · Cited by 34
Gillette-Guyonnet, S. (2003) · Mechanisms of Ageing and Development · doi:10.1016/s0047-6374(02)00199-9 · Cited by 32
Wireless Vital Sign Monitoring in Pregnant Women: A Functionality and Acceptability Study
Boatin, A. A., Wylie, B. J., Goldfarb, I., Azevedo, R., Pittel, E., Ng, C., & Haberer, J. E. (2016) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0173 · Cited by 30
Mielke, G. I., de Almeida Mendes, M., Ekelund, U., Rowlands, A. V., Reichert, F. F., & Crochemore‐Silva, I. (2023) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14416 · Cited by 26
“Bland– Altman methods 19,20 were used to examine the agreement between outputs from different brands (GA and AG), worn at the same wear-site (non-dominant wrist), and between outputs from the same brand (AG) worn at three wear-sites (waist, dominant wrist, and non-dominant wrist).”
MethodJames, D., Umekwe, N., Edeoga, C., Nyenwe, E., & Dagogo-Jack, S. (2020) · Metabolism · doi:10.1016/j.metabol.2020.154263 · Cited by 23
Automated quantitative evaluation of fetal atrioventricular annular plane systolic excursion
Herling, L., Johnson, J., Ferm‐Widlund, K., Zamprakou, A., Westgren, M., & Acharya, G. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23703 · Cited by 22
van Hooff, M., Meijer, E. J., Scheltinga, M. R. M., Savelberg, H. H. C. M., & Schep, G. (2022) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12738 · Cited by 20
Ginsburg, A. S., Nkwopara, E., Macharia, W., Ochieng, R., Waiyego, M., Zhou, G., Karasik, R., Xu, S., & Ansermino, J. M. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-035184 · Cited by 16
Proper use of noncontact infrared thermometry for temperature screening during COVID-19
Hussain, A. S., Hussain, H. S., Betcher, N., Behm, R., & Cagir, B. (2021) · Scientific Reports · doi:10.1038/s41598-021-90100-1 · Cited by 16
Pianta, M. J., Makrai, E., Verspoor, K. M., Cohn, T. A., & Downie, L. E. (2018) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2018.07.015 · Cited by 15
Dante, A., Franconi, I., Marucci, A. R., Alfes, C. M., & Lancia, L. (2020) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2019.11.014 · Cited by 13
Turnes, T., Penteado dos Santos, R., de Aguiar, R. A., Loch, T., Possamai, L. T., & Caputo, F. (2019) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0675 · Cited by 15
Therapy monitoring in congenital adrenal hyperplasia by dried blood samples
Wieacker, I., Peter, M., Borucki, K., Empting, S., Roehl, F.-W., & Mohnike, K. (2015) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2014-0303 · Cited by 14
Metadata
- Authors
- Bland, J. M., & Altman, D. G.
- Affiliations
- St George's, University of London (GB)
- University of Oxford (GB)
- ORCID
- Altman, Douglas G
- Venue
- Statistical Methods in Medical Research
- Publisher
- SAGE Publications
- Published
- 1999-04
- Volume
- 8
- Issue
- 2
- Pages
- 135-160
- ISSN
- 0962-2802 (ISSN-L)
- 1477-0334
- OpenAlex
- W2159759971
- Cited by
- 9,619
- References
- 25
- Citations by year
- 2026: 393 · 2025: 421 · 2024: 483 · 2023: 494 · 2022: 559 · 2021: 681 · 2020: 610 · 2019: 506 · 2018: 485 · 2017: 457 · 2016: 412 · 2015: 437 · 2014: 461 · 2013: 388 · 2012: 401
- FWCI
- 47.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Statistical Methods in Medical Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Keywords
- method comparison, measurement agreement, limits of agreement, mean difference, repeatability, regression analysis, logarithmic transformation, repeated measures, nonparametric comparison, graphical method, confidence intervals
- MeSH terms
- Humans, Medical Laboratory Science, Reproducibility of Results, Confidence Intervals, Linear Models, Statistics, Nonparametric, Clinical Laboratory Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review