Validity of activity monitors in health and chronic disease: a systematic review
Open accessThe DOI matches its Crossref record; 153 of the 153 references it cites were found in a registry or an index.
Abstract
The assessment of physical activity in healthy populations and in those with chronic diseases is challenging. The aim of this systematic review was to identify whether available activity monitors (AM) have been appropriately validated for use in assessing physical activity in these groups. Following a systematic literature search we found 134 papers meeting the inclusion criteria; 40 conducted in a field setting (validation against doubly labelled water), 86 in a laboratory setting (validation against a metabolic cart, metabolic chamber) and 8 in a field and laboratory setting. Correlation coefficients between AM outcomes and energy expenditure (EE) by the criterion method (doubly labelled water and metabolic cart/chamber) and percentage mean differences between EE estimation from the monitor and EE measurement by the criterion method were extracted. Random-effects meta-analyses were performed to pool the results across studies where possible. Types of devices were compared using meta-regression analyses. Most validation studies had been performed in healthy adults (n = 118), with few carried out in patients with chronic diseases (n = 16). For total EE, correlation coefficients were statistically significantly lower in uniaxial compared to multisensor devices. For active EE, correlations were slightly but not significantly lower in uniaxial compared to triaxial and multisensor devices. Uniaxial devices tended to underestimate TEE (−12.07 (95%CI; -18.28 to −5.85) %) compared to triaxial (−6.85 (95%CI; -18.20 to 4.49) %, p = 0.37) and were statistically significantly less accurate than multisensor devices (−3.64 (95%CI; -8.97 to 1.70) %, p<0.001). TEE was underestimated during slow walking speeds in 69% of the lab validation studies compared to 37%, 30% and 37% of the studies during intermediate, fast walking speed and running, respectively. The high level of heterogeneity in the validation studies is only partly explained by the type of activity monitor and the activity monitor outcome. Triaxial and multisensor devices tend to be more valid monitors. Since activity monitors are less accurate at slow walking speeds and information about validated activity monitors in chronic disease populations is lacking, proper validation studies in these populations are needed prior to their inclusion in clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1985) · Europe PMC (PubMed Central) · Cited by 9,143
Health benefits of physical activity: the evidence
Warburton, D. E. R. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.051351 · Cited by 8,007 · cited 1×
“chronic diseases [1].”
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 1×
“Actigraph Model 7164 (formerly CSA, MTI) Actigraph LLC Pensacola, FL F [14-24] + L [7,25-47] 5.”
BackgroundApplying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
The Effect of Social Desirability and Social Approval on Self-Reports of Physical Activity
Adams, S. A. (2005) · American Journal of Epidemiology · doi:10.1093/aje/kwi054 · Cited by 1,160 · cited 1×
“Actigraph Model 7164 (formerly CSA, MTI) Actigraph LLC Pensacola, FL F [14-24] + L [7,25-47] 5.”
BackgroundIs physical activity or physical fitness more important in defining health benefits?
BLAIR, S. N., CHENG, Y., & SCOTT HOLDER, J. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200106001-00007 · Cited by 1,118
Garcia-Aymerich, J., Lange, P., Benet, M., Schnohr, P., & Anto, J. M. (2006) · Thorax · doi:10.1136/thx.2006.060145 · Cited by 1,113
Peripheral muscle weakness contributes to exercise limitation in COPD.
Gosselink, R., Troosters, T., & Decramer, M. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.3.8630582 · Cited by 1,027
Self-citationBouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Physical activity in patients with COPD
Watz, H., Waschki, B., Meyer, T., & Magnussen, H. (2009) · European Respiratory Journal · doi:10.1183/09031936.00024608 · Cited by 684
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Utility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 2×
“GENEA Unilever Discovery, Sharnbrook Bedfordshire, UK F [115] + L [55] 3,6 x 3,0 x 1,2 cm (16 g) Wrist, waist, ankle NA NA 8 days VMU EE”
BackgroundKumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 513
The validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Self-citationOhkawara, K., Oshima, Y., Hikihara, Y., Ishikawa-Takata, K., Tabata, I., & Tanaka, S. (2011) · British Journal of Nutrition · doi:10.1017/s0007114510005441 · Cited by 458
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
JOHANNSEN, D. L., CALABRO, M. A., STEWART, J., FRANKE, W., ROOD, J. C., & WELK, G. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e0b3ff · Cited by 424
Validity of the Computer Science and Applications, Inc. (CCA) activity monitor
MELANSON, E. L., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199506000-00021 · Cited by 416
Evaluation of a portable device to measure daily energy expenditure in free-living adults
St-Onge, M., Mignault, D., Allison, D. B., & Rabasa-Lhoret, R. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.3.742 · Cited by 397
Physical Inactivity and Obesity: A Vicious Circle
Pietiläinen, K. H., Kaprio, J., Borg, P., Plasqui, G., Yki‐Järvinen, H., Kujala, U. M., Rose, R. J., Westerterp, K. R., & Rissanen, A. (2008) · Obesity · doi:10.1038/oby.2007.72 · Cited by 388 · cited 1×
“Tracmor Philips Research, Eindhoven, The Netherlands F [87-94] + L [95-97] 7.”
BackgroundEstimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise
JAKICIC, J. M., MARCUS, M., GALLAGHER, K. I., RANDALL, C., THOMAS, E., GOSS, F. L., & ROBERTSON, R. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126805.32659.43 · Cited by 362
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360 · cited 1×
“cerebral palsy, lower limb amputation), 3) studies only investigating the number of steps using pedometers because of the inaccuracy in measurement of total energy expenditure [7] and lack of ability to measure physical activity patterns [8].”
BackgroundPredicting Activity Energy Expenditure Using the Actical® Activity Monitor
Heil, D. P. (2006) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2006.10599333 · Cited by 349
Corey, D. M., Dunlap, W. P., & Burke, M. J. (1998) · The Journal of General Psychology · doi:10.1080/00221309809595548 · Cited by 348
A novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
A comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297 · cited 1×
“ActivPAL PAL Technologies Ltd, Glasgow, UK L [57,72-74] 5 x 3,5 x 0,7 cm (15 g) midline on the anterior aspect of the thigh NA 1 s to 1 min 10 days Steps (cadence), different body positions, activity score”
Methodvan Hees, V. T., Renström, F., Wright, A., Gradmark, A., Catt, M., Chen, K. Y., Löf, M., Bluck, L., Pomeroy, J., Wareham, N. J., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022922 · Cited by 289
Level of daily physical activity in individuals with COPD compared with healthy controls
Vorrink, S. N., Kort, H. S., Troosters, T., & Lammers, J.-W. J. (2011) · Respiratory Research · doi:10.1186/1465-9921-12-33 · Cited by 272
Self-citationEvaluation of methods to assess physical activity in free-living conditions
J. M. LEENDERS, N. Y., MICHAEL SHERMAN, W., NAGARAJA, H. N., & LAWRENCE KIEN, C. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200107000-00024 · Cited by 255
Comparison of Activity Monitors to Estimate Energy Cost of Treadmill Exercise
KING, G. A., TORRES, N., POTTER, C., BROOKS, T. J., & COLEMAN, K. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132379.09364.f8 · Cited by 238
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236 · cited 1×
“Actiheart Mini Mitter Sunriver, OR, USA L [29,108,139] 0.”
BackgroundPedometer Accuracy in Nursing Home and Community-Dwelling Older Adults
CYARTO, E. V., MYERS, A. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113476.62469.98 · Cited by 236
Comparative Validity of Physical Activity Measures in Older Adults
COLBERT, L. H., MATTHEWS, C. E., HAVIGHURST, T. C., KIM, K., & SCHOELLER, D. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181fc7162 · Cited by 224
Bouten, C. V., Verboeket-van de Venne, W. P., Westerterp, K. R., Verduin, M., & Janssen, J. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.2.1019 · Cited by 223
Guazzi, M., Dickstein, K., Vicenzi, M., & Arena, R. (2009) · Circulation: Heart Failure · doi:10.1161/circheartfailure.109.881326 · Cited by 223
Lyden, K., Kozey, S. L., Staudenmeyer, J. W., & Freedson, P. S. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1639-8 · Cited by 222 · cited 2×
“Actigraph Model GT1M Actigraph LLC Pensacola, FL F [48-50] + L [29,49,51-57] 3.”
BackgroundImproving energy expenditure estimation by using a triaxial accelerometer
Chen, K. Y., & Sun, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.2112 · Cited by 211
Nichols, J. F., Morgan, C. G., Chabot, L. E., Sallis, J. F., & Calfas, K. J. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.10608878 · Cited by 203
Validity of physical activity monitors in adults participating in free-living activities
Berntsen, S., Hageberg, R., Aandstad, A., Mowinckel, P., Anderssen, S. A., Carlsen, K.-H., & Andersen, L. B. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.048868 · Cited by 191
Measuring Free‐Living Energy Expenditure and Physical Activity with Triaxial Accelerometry
Plasqui, G., Joosen, A. M. C. P., Kester, A. D., Goris, A. H. C., & Westerterp, K. R. (2005) · Obesity Research · doi:10.1038/oby.2005.165 · Cited by 183
PATTERSON, S. M., KRANTZ, D. S., MONTGOMERY, L. C., DEUSTER, P. A., HEDGES, S. M., & NEBEL, L. E. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb03356.x · Cited by 179
Steele, B. G., Belza, B., Cain, K., Warms, C., Coppersmith, J., & Howard, J. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.10.0045 · Cited by 176
Accelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174 · cited 1×
“Actigraph Model GT1M Actigraph LLC Pensacola, FL F [48-50] + L [29,49,51-57] 3.”
BackgroundPhysical Activity and Clinical and Functional Status in COPD
Garcia-Aymerich, J., Serra, I., Gómez, F. P., Farrero, E., Balcells, E., Rodríguez, D. A., de Batlle, J., Gimeno, E., Donaire-Gonzalez, D., Orozco-Levi, M., et al. (2009) · Chest · doi:10.1378/chest.08-2532 · Cited by 167
Total free living energy expenditure in patients with severe chronic obstructive pulmonary disease.
Baarends, E. M., Schols, A. M., Pannemans, D. L., Westerterp, K. R., & Wouters, E. F. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.2.9032193 · Cited by 166
Physical activity in daily life in patients with chronic low back pain
Verbunt, J. A., Westerterp, K. R., van der Heijden, G. J., Seelen, H. A., Vlaeyen, J. W., & Knottnerus, J. A. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.23182 · Cited by 162
The reliability, validity, and stability of a measure of physical activity in the elderly
Kochersberger, G., McConnell, E., Kuchibhatla, M. N., & Pieper, C. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90258-0 · Cited by 159
Gait Speed and Step-Count Monitor Accuracy in Community-Dwelling Older Adults
STORTI, K. L., PETTEE, K. K., BRACH, J. S., TALKOWSKI, J. B., RICHARDSON, C. R., & KRISKA, A. M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318158b504 · Cited by 155
Validation of an Armband to Measure Daily Energy Expenditure in Older Adults
Mackey, D. C., Manini, T. M., Schoeller, D. A., Koster, A., Glynn, N. W., Goodpaster, B. H., Satterfield, S., Newman, A. B., Harris, T. B., Cummings, S. R., et al. (2011) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glr101 · Cited by 153
The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure
JAKICIC, J. M., WINTERS, C., LAGALLY, K., HO, J., ROBERTSON, R. J., & WING, R. R. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199905000-00020 · Cited by 149
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Yamada, Y., Yokoyama, K., Noriyasu, R., Osaki, T., Adachi, T., Itoi, A., Naito, Y., Morimoto, T., Kimura, M., & Oda, S. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0883-7 · Cited by 141
Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease
Hill, K., Dolmage, T. E., Woon, L., Goldstein, R., & Brooks, D. (2010) · Thorax · doi:10.1136/thx.2009.128702 · Cited by 135
Assessment of physical activity in older individuals: a doubly labeled water study
Starling, R. D., Matthews, D. E., Ades, P. A., & Poehlman, E. T. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.6.2090 · Cited by 134
Abel, M. G., Hannon, J. C., Sell, K., Lillie, T., Conlin, G., & Anderson, D. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h08-103 · Cited by 134
Validity of the Actical Accelerometer Step-Count Function
ESLIGER, D. W., PROBERT, A., GORBER, S. C., BRYAN, S., LAVIOLETTE, M., & TREMBLAY, M. S. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3804ec4e9 · Cited by 129
Validation of the SenseWear Armband at high intensity exercise
Drenowatz, C. J., & Eisenmann, J. C. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1695-0 · Cited by 123
Validation of MET estimates and step measurement using the ActivPAL physical activity logger
Harrington, D. M., Welk, G. J., & Donnelly, A. E. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2010.549499 · Cited by 123
Validation of two activity monitors in patients with COPD
Langer, D., Gosselink, R., Sena, R., Burtin, C., Decramer, M., & Troosters, T. (2009) · Thorax · doi:10.1136/thx.2008.112102 · Cited by 123
Self-citationEstimating Absolute and Relative Physical Activity Intensity Across Age via Accelerometry in Adults
Miller, N. E., Strath, S. J., Swartz, A. M., & Cashin, S. E. (2010) · Journal of Aging and Physical Activity · doi:10.1123/japa.18.2.158 · Cited by 118
Predicting Energy Expenditure of Physical Activity Using Hip- and Wrist-Worn Accelerometers
Chen, K. Y., Acra, S. A., Majchrzak, K., Donahue, C. L., Baker, L., Clemens, L., Sun, M., & Buchowski, M. S. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322641088 · Cited by 116
Validity of the simultaneous heart rate-motion sensor technique for measuring energy expenditure
STRATH, S. J., BASSETT, D. R., THOMPSON, D. L., & SWARTZ, A. M. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200205000-00025 · Cited by 112
Physical inactivity as a determinant of the physical activity level in the elderly
Meijer, E. P., Goris, A. H. C., Wouters, L., & Westerterp, K. R. (2001) · International Journal of Obesity · doi:10.1038/sj.ijo.0801644 · Cited by 112
Ability of Different Physical Activity Monitors to Detect Movement During Treadmill Walking
Leenders, N. Y., Nelson, T. E., & Sherman, W. M. (2003) · International Journal of Sports Medicine · doi:10.1055/s-2003-37196 · Cited by 110
Field evaluation of energy expenditure in women using Tritrac accelerometers
CAMPBELL, K. L., CROCKER, P. R. E., & MCKENZIE, D. C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200210000-00020 · Cited by 107
Estimation of Oxygen Uptake during Fast Running Using Accelerometry and Heart Rate
FUDGE, B. W., WILSON, J., EASTON, C., IRWIN, L., CLARK, J., HADDOW, O., KAYSER, B., & PITSILADIS, Y. P. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000235884.71487.21 · Cited by 103
Validation of the Tracmor triaxial accelerometer system for walking
LEVINE, J. A., BAUKOL, P. A., & WESTERTERP, K. R. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200109000-00024 · Cited by 102
Evaluation of the SenseWear activity monitor during exercise in cystic fibrosis and in health
Dwyer, T., Alison, J. A., McKeough, Z. J., Elkins, M. R., & Bye, P. T. P. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.04.013 · Cited by 102
Bonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R. (2010) · Obesity · doi:10.1038/oby.2010.34 · Cited by 100
Evaluation of the Portable HealthWear Armband
Mignault, D., St.-Onge, M., Karelis, A. D., Allison, D. B., & Rabasa-Lhoret, R. (2005) · Diabetes Care · doi:10.2337/diacare.28.1.225-a · Cited by 95
Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
PAMBIANCO, G., WING, R. R., & ROBERTSON, R. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00020 · Cited by 93
Ades, P. A., Savage, P. D., Brochu, M., Tischler, M. D., Lee, N. M., & Poehlman, E. T. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00360.2004 · Cited by 93
Furlanetto, K. C., Bisca, G. W., Oldemberg, N., Sant'Anna, T. J., Morakami, F. K., Camillo, C. A., Cavalheri, V., Hernandes, N. A., Probst, V. S., Ramos, E. M., et al. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.024 · Cited by 87 · cited 1×
“Sensewear Pro Armband (formerly Healthwear Armband) Bodymedia, Pittsburgh, PA, USA F [50,122-126] + L [32,46,100, 125-138] 8.”
BackgroundEnergy expenditure during daily activities as measured by two motion sensors in patients with COPD
Cavalheri, V., Donária, L., Ferreira, T., Finatti, M. E., Camillo, C. A., Ramos, E. M. C., & Pitta, F. D. O. (2011) · European Respiratory Journal · doi:10.1016/j.rmed.2011.01.004 · Cited by 86
Spierer, D. K., Hagins, M., Rundle, A., & Pappas, E. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1672-7 · Cited by 86
Comparison of accelerometers with oxygen consumption in older adults during exercise
FEHLING, P. C., SMITH, D. L., WARNER, S. E., & DALSKY, G. P. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199901000-00026 · Cited by 85
van Hees, V. T., van Lummel, R. C., & Westerterp, K. R. (2009) · Obesity · doi:10.1038/oby.2009.55 · Cited by 85
Use of a triaxial accelerometer to validate reported food intakes
Goris, A. H. C., Meijer, E. P., Kester, A. D. M., & Westerterp, K. R. (2001) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/73.3.549 · Cited by 83
Assessing Energy Expenditure in Male Endurance Athletes: Validity of the SenseWear Armband
Koehler, K., BRAUN, H., de Marées, M., Fusch, G., Fusch, C., & Schaenzer, W. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820750f5 · Cited by 81
Accelerometer Prediction of Energy Expenditure: Vector Magnitude Versus Vertical Axis
HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181aa3a0e · Cited by 78
RAFAMANTANANTSOA, H. H., EBINE, N., YOSHIOKA, M., HIGUCHI, H., YOSHITAKE, Y., TANAKA, H., SAITOH, S., & JONES, P. J. H. (2002) · Journal of Nutritional Science and Vitaminology · doi:10.3177/jnsv.48.517 · Cited by 77
Annegarn, J., Spruit, M. A., Uszko‐Lencer, N. H. M. K., Vanbelle, S., Savelberg, H. H. C. M., Schols, A. M. W. J., Wouters, E. F. �., & Meijer, K. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.06.021 · Cited by 75
Cole, P. J., LeMura, L. M., Klinger, T., Strohecker, K., & McConnell, T. R. (2004) · PubMed · Cited by 74
Energy Expenditure Estimated by Accelerometry and Doubly Labeled Water: Do They Agree?
LEENDERS, N. Y., SHERMAN, W. M., & NAGARAJA, H. N. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000235883.94357.95 · Cited by 73
Predicting walking METs and energy expenditure from speed or accelerometry
BROOKS, A. G., GUNN, S. M., WITHERS, R. T., GORE, C. J., & PLUMMER, J. L. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000170074.19649.0e · Cited by 73
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69 · cited 1×
“Actigraph Model 7164 (formerly CSA, MTI) Actigraph LLC Pensacola, FL F [14-24] + L [7,25-47] 5.”
BackgroundHustvedt, B.-E., Christophersen, A., Johnsen, L. R., Tomten, H., McNeill, G., Haggarty, P., & Løvø, A. (2004) · British Journal of Nutrition · doi:10.1079/bjn20041272 · Cited by 69
Assessment of energy expenditure in overweight women
FOGELHOLM, M., HIILLOSKORPI, H., LAUKKANEN, R., OJA, P., VAN MARKEN LICHTENBELT, W., & WESTERTERP, K. (1998) · Medicine& Science in Sports & Exercise · doi:10.1097/00005768-199808000-00002 · Cited by 68
Accuracy of Physical Activity Monitors in Pregnant Women
CONNOLLY, C. P., COE, D. P., KENDRICK, J. M., BASSETT, D. R., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182058883 · Cited by 67
Validation of the Actical Activity Monitor in Middle-Aged and Older Adults
Hooker, S. P., Feeney, A., Hutto, B., Pfeiffer, K. A., McIver, K., Heil, D. P., Vena, J. E., LaMonte, M. J., & Blair, S. N. (2011) · Journal of Physical Activity and Health · doi:10.1123/jpah.8.3.372 · Cited by 67
Validation of the ActiGraph Two-Regression Model for Predicting Energy Expenditure
ROTHNEY, M. P., BRYCHTA, R. J., MEADE, N. N., CHEN, K. Y., & BUCHOWSKI, M. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d5a984 · Cited by 65
Validity of three accelerometers during treadmill walking and motor vehicle travel
Maddocks, M., Petrou, A., Skipper, L., & Wilcock, A. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.051128 · Cited by 64
Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors
WELK, G. J., ALMEIDA, J., & MORSS, G. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000069525.56078.22 · Cited by 62
Jacobi, D., Perrin, A., Grosman, N., Doré, M., Normand, S., Oppert, J., & Simon, C. (2007) · Obesity · doi:10.1038/oby.2007.605 · Cited by 59
Validity of the Actical for estimating free-living physical activity
Crouter, S. E., DellaValle, D. M., Horton, M., Haas, J. D., Frongillo, E. A., & Bassett, D. R. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1758-2 · Cited by 59
Gardner, A. W., Womack, C. J., Sieminski, D. J., Montgomery, P. S., Killewich, L. A., & Fonong, T. (1998) · Angiology · doi:10.1177/000331979804900501 · Cited by 58
Statistical Methods for the Validation of Questionnaires: Discrepancy between Theory and Practice
Schmidt, M. E., & Steindorf, K. (2006) · Methods of Information in Medicine · doi:10.1055/s-0038-1634096 · Cited by 57 · cited 1×
“A systematic review of the statistical methods used to validate physical activity questionnaires revealed similar findings, with the majority of the studies using correlation analysis compared to Bland and Altman analysis [153].”
MethodLöf, M. (2011) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2011.129 · Cited by 57
Cellular Telephones Measure Activity and Lifespace in Community‐Dwelling Adults: Proof of Principle
Schenk, A. K., Witbrodt, B. C., Hoarty, C. A., Carlson, R. H., Goulding, E. H., POTTER, J. F., & Bonasera, S. J. (2011) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2010.03267.x · Cited by 55
Statistical methods for the validation of questionnaires--discrepancy between theory and practice.
Schmidt, M. E., & Steindorf, K. (2006) · PubMed · Cited by 55
Comparison of Lifecorder EX and ActiGraph accelerometers under free-living conditions
McClain, J. J., Craig, C. L., Sisson, S. B., & Tudor-Locke, C. (2007) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-060 · Cited by 55
PHYSICAL ACTIVITY OR CARDIORESPIRATORY FITNESS: WHICH IS A MORE IMPORTANT PREDICTOR OF MORTALITY?
Blair, S. N., Cheng, Y., Holder, S., Barlow, C. E., & Kampert, J. B. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105001-01549 · Cited by 55
Polar Activity Watch 200: a new device to accurately assess energy expenditure
Brugniaux, J. V., Niva, A., Pulkkinen, I., Laukkanen, R. M. T., Richalet, J.-P., & Pichon, A. P. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.045575 · Cited by 54
Lof, M., Hannestad, U., & Forsum, E. (2003) · British Journal of Nutrition · doi:10.1079/bjn2003975 · Cited by 52
Predicting Physical Activity Energy Expenditure Using Accelerometry in Adults From Sub‐Sahara Africa
Assah, F. K., Ekelund, U., Brage, S., Corder, K., Wright, A., Mbanya, J. C., & Wareham, N. J. (2009) · Obesity · doi:10.1038/oby.2009.39 · Cited by 51
Comparison of two different physical activity monitors
Paul, D. R., Kramer, M., Moshfegh, A. J., Baer, D. J., & Rumpler, W. V. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-26 · Cited by 51
Influence of body composition on physical activity validation studies using doubly labeled water
Mâsse, L. C., Fulton, J. E., Watson, K. L., Mahar, M. T., Meyers, M. C., & Wong, W. W. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00901.2003 · Cited by 50
Estimating Energy Expenditure With the RT3 Triaxial Accelerometer
Maddison, R., Jiang, Y., Hoorn, S. V., Mhurchú, C. N., Lawes, C. M. M., Rodgers, A., & Rush, E. C. (2009) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2009.10599559 · Cited by 49
Measuring physical strain during ambulation with accelerometry
HARTGERINK, J. B. J. B. O., VAN DER WOUDE, L. H. V., & STAM, H. J. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200008000-00015 · Cited by 46
Detecting Bouts of Physical Activity in a Field Setting
Mâsse, L. C., Fulton, J. E., Watson, K. L., Heesch, K. C., Kohl, H. W., Blair, S. N., & Tortolero, S. R. (1999) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1999.10608041 · Cited by 44
Physical activity monitor for recording energy expenditure in pregnancy
Berntsen, S., Stafne, S. N., & Mørkved, S. (2011) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/j.1600-0412.2011.01172.x · Cited by 44
A validation of a physical activity monitor for young and older adults.
Jf, N., Patterson, P., & Early, T. (1992) · PubMed · Cited by 44
Hikihara, Y., Tanaka, S., Ohkawara, K., Ishikawa‐Takata, K., & Tabata, I. (2012) · Journal of Physical Activity and Health · doi:10.1123/jpah.9.7.935 · Cited by 43
Physical activity and energy expenditure in lean and obese adult human subjects
Meijer, G. A. L., Westerterp, K. R., van Hulsel, A. M. P., & ten Hoor, F. (1992) · European Journal of Applied Physiology · doi:10.1007/bf00602359 · Cited by 40
Energy Expenditure Prediction Using a Miniaturized Ear-Worn Sensor
Atallah, L., Leong, J., Lo, B. P. L., & Yang, G. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182093014 · Cited by 37
Correlations between the step activity monitor and the DynaPort ADL-monitor
Brandes, M., & Rosenbaum, D. (2003) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2003.08.001 · Cited by 36
Accelerometry combined with heart rate telemetry in the assessment of total energy expenditure
Johansson, H. P., Rossander-Hulthén, L., Slinde, F., & Ekblom, B. (2006) · British Journal of Nutrition · doi:10.1079/bjn20051527 · Cited by 35
CARTER, J. H., Wilkinson, D. R., Blacker, S. D., Rayson, M. P., Bilzon, J., Izard, R. M., Coward, A. W., Wright, A., Nevill, A. M., Rennie, K. L., et al. (2008) · Journal of Sports Sciences · doi:10.1080/02640410701708979 · Cited by 34
Comparative Validity Assessment of Five Activity Monitors: Does Being a Child Matter?
Stone, M. R., Esliger, D., & Tremblay, M. S. (2007) · Pediatric Exercise Science · doi:10.1123/pes.19.3.291 · Cited by 33
Focht, B. C., Sanders, W. M., Brubaker, P. H., & Rejeski, W. J. (2003) · Journal of Aging and Physical Activity · doi:10.1123/japa.11.3.293 · Cited by 32
Arvidsson, D., Slinde, F., Nordenson, A., Larsson, S., & Hulthén, L. (2005) · Clinical Nutrition · doi:10.1016/j.clnu.2005.09.001 · Cited by 31
Ohkawara, K., Ishikawa‐Takata, K., Park, J. H., Tabata, I., & Tanaka, S. (2011) · BMC Research Notes · doi:10.1186/1756-0500-4-512 · Cited by 30
Heiermann, S., Hedayati, K. K., Müller, M. J., & Dittmar, M. (2010) · Gerontology · doi:10.1159/000322109 · Cited by 28
Tsang, T. W., Kohn, M. R., Chow, C. M., & Singh, M. A. F. (2010) · Journal of Obesity · doi:10.1155/2010/672751 · Cited by 28
Predicting Energy Expenditure in Elders with the Metabolic Cost of Activities
Choquette, S., CHUIN, A., David-ALexandre, L., Brochu, M., & Dionne, I. J. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181a6164a · Cited by 26
Validity of the Nike+Device During Walking and Running
Kane, N. A., Simmons, M. C., John, D., Thompson, D. L., & Bassett, D. R. (2009) · International Journal of Sports Medicine · doi:10.1055/s-0029-1242810 · Cited by 24
Comparison of Accelerometry and Oxymetry for Measuring Daily Physical Activity.
Yokoyama, Y., Kawamura, T., Tamakoshi, A., Noda, A., Hirai, M., Saito, H., & Ohno, Y. (2002) · Circulation Journal · doi:10.1253/circj.66.751 · Cited by 23
Fuller, Z., Horgan, G. W., O’Reilly, L., Ritz, P., Milne, E., & Stubbs, R. J. (2007) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602739 · Cited by 22
Energy expenditure in young adult urban informal settlement dwellers in South Africa
Dugas, L. R., Carstens, M., Ebersole, K., Schoeller, D. A., Durazo-Arvizú, R., Lambert, E. V., & Luke, A. H. (2009) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2008.75 · Cited by 22
Epidemiology: Every bite you take
Borrell, B. (2011) · Nature · doi:10.1038/470320a · Cited by 19
Comparison of the RT3 Research Tracker and Tritrac R3D Accelerometers
DeVoe, D. E., Gotshall, R. W., & McArthur, T. (2003) · Perceptual and Motor Skills · doi:10.2466/pms.2003.97.2.510 · Cited by 19
An Accelerometer-Based Earpiece to Monitor and Quantify Physical Activity
Manohar, C. U., McCrady, S. K., Pavlidis, I. T., & Levine, J. A. (2009) · Journal of Physical Activity and Health · doi:10.1123/jpah.6.6.781 · Cited by 18
A Clinical Evaluation of a Remote Mobility Monitoring System based on SMS Messaging
Dalton, A. F., Scanaill, C. N., Carew, S., Lyons, D., & OLaighin, G. M. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352792 · Cited by 18
Accuracy of a novel multi-sensor board for measuring physical activity and energy expenditure
Duncan, G. E., Lester, J., Migotsky, S., Goh, J., Higgins, L., & Borriello, G. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1834-2 · Cited by 16
Munguía‐Izquierdo, D., Santalla, A., & Legaz‐Arrese, A. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.08.021 · Cited by 15
Kuffel, E. E., Crouter, S. E., Haas, J. D., Frongillo, E. A., & Bassett, D. R. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-92 · Cited by 15
Measurement of daily activity in restrictive type anorexia nervosa
Harris, A. M., McAlpine, D. E., Shirbhate, R., Manohar, C. U., & Levine, J. A. (2007) · International Journal of Eating Disorders · doi:10.1002/eat.20486 · Cited by 13
Validation of a Novel Physical Activity Assessment Device in Morbidly Obese Females
Kwon, S., Jamal, M., Zamba, G. K. D., Stumbo, P., & Samuel, I. (2010) · Journal of Obesity · doi:10.1155/2010/856376 · Cited by 11
Edwards, A. G., Hill, J. O., Byrnes, W. C., & Browning, R. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181bd196d · Cited by 10
Horner, F. E., Rayson, M. P., & Bilzon, J. (2011) · International Journal of Obesity · doi:10.1038/ijo.2011.39 · Cited by 10
CARDIOVASCULAR ADAPTATIONS TO DECONDITIONING
Levine, B. D., Dallas, T. X., & Delp, M. D. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105001-01271 · Cited by 10
Comparison of two physical activity monitors during a 1-mile walking field test
Hageman, P. A., NORMAN, J. F., Pfefferkorn, K. L., Reiss, N. J., & Riesberg, K. A. (2004) · Cited by 7
Cited by
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Diaz, K. M., Howard, V. J., Hutto, B., Colabianchi, N., Vena, J. E., Safford, M. M., Blair, S. N., & Hooker, S. P. (2017) · Annals of Internal Medicine · doi:10.7326/m17-0212 · Cited by 530
An official European Respiratory Society statement on physical activity in COPD
Watz, H., Pitta, F., Rochester, C. L., Garcia-Aymerich, J., ZuWallack, R., Troosters, T., Vaes, A. W., Puhan, M. A., Jehn, M., Polkey, M. I., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00046814 · Cited by 526
Self-citationSullivan, A. N., & Lachman, M. E. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2016.00289 · Cited by 458
Mercer, K., Giangregorio, L., Schneider, E., Chilana, P., Li, M., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4225 · Cited by 419
“The BodyMedia FIT and Fitbit Zip trackers have been shown to provide valid measures of daily energy expenditures [27-30].”
Metadata
- Authors
- Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., Peterson, B. T., Wilson, F., Mann, B., Rabinovich, R., Puhan, M. A., Troosters, T., & PROactive consortium
- Venue
- International Journal of Behavioral Nutrition and Physical Activity
- Published
- 2012-07-09
- Volume
- 9
- Issue
- 1
- Pages
- 84-84
- ISSN
- 1479-5868 (ISSN-L)
- OpenAlex
- W2160638979
- Cited by
- 277
- References
- 153
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.