Optical Coherence Tomography
Open accessAbstract
A technique called optical coherence tomography (OCT) has been developed for noninvasive cross-sectional imaging in biological systems. OCT uses low-coherence interferometry to produce a two-dimensional image of optical scattering from internal tissue microstructures in a way that is analogous to ultrasonic pulse-echo imaging. OCT has longitudinal and lateral spatial resolutions of a few micrometers and can detect reflected signals as small as ∼10 -10 of the incident optical power. Tomographic imaging is demonstrated in vitro in the peripapillary area of the retina and in the coronary artery, two clinically relevant examples that are representative of transparent and turbid media, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Waves and fields in optoelectronics
Haus, H. A. (1983) · Medical Entomology and Zoology · Cited by 2,153
Retinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
Lynch, D. K. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000558 · Cited by 754
Confocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Optical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Ballistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr Gate
Wang, L., Ho, P. P., Liu, C., Zhang, G., & Alfano, R. R. (1991) · Science · doi:10.1126/science.253.5021.769 · Cited by 552
Eye-length measurement by interferometry with partially coherent light
Fercher, A. F., Mengedoht, K., & Werner, W. (1988) · Optics Letters · doi:10.1364/ol.13.000186 · Cited by 516
Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain.
Chance, B., Leigh, J. S., Miyake, H., Smith, D. S., Nioka, S., Greenfeld, R., Finander, M., Kaufmann, K., Levy, W., & Young, M. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.14.4971 · Cited by 464
Weinreb, R. N. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070060105058 · Cited by 449
Cited by
Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance
Hirsch, L. R., Stafford, R. J., Bankson, J. A., Sershen, S. R., Rivera, B., Price, R. E., Hazle, J. D., Halas, N. J., & West, J. L. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2232479100 · Cited by 3,955
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El-Sayed, M. A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15237h · Cited by 3,550
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Clinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Recent developments in compact ultrafast lasers
Keller, U. (2003) · Nature · doi:10.1038/nature01938 · Cited by 2,291
Pappu, R., Recht, B., Taylor, J., & Gershenfeld, N. (2002) · Science · doi:10.1126/science.1074376 · Cited by 2,018
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Tearney, G. J., Regar, E., Akasaka, T., Adriaenssens, T., Barlis, P., Bezerra, H. G., Bouma, B., Bruining, N., Cho, J.-M., Chowdhary, S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.079 · Cited by 1,874
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Self-citationQuantitative phase imaging in biomedicine
Park, Y., Depeursinge, C., & Popescu, G. (2018) · Nature Photonics · doi:10.1038/s41566-018-0253-x · Cited by 1,802
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Self-citationAge-related macular degeneration
Lim, L. S., Mitchell, P., Seddon, J. M., Holz, F. G., & Wong, T. Y. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60282-7 · Cited by 1,717
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Self-citationNon-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Controlling waves in space and time for imaging and focusing in complex media
Mosk, A. P., Lagendijk, A., Lerosey, G., & Fink, M. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.88 · Cited by 1,536
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Gold Nanocages: Synthesis, Properties, and Applications
Skrabalak, S. E., Chen, J., Sun, Y., Lu, X., Au, L., Cobley, C. M., & Xia, Y. (2008) · Accounts of Chemical Research · doi:10.1021/ar800018v · Cited by 1,447
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Self-citationNear-Infrared Resonant Nanoshells for Combined Optical Imaging and Photothermal Cancer Therapy
Gobin, A. M., Lee, M. H., Halas, N. J., James, W. D., Drezek, R. A., & West, J. L. (2007) · Nano Letters · doi:10.1021/nl070610y · Cited by 1,314
Imaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Self-citationde Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Non-invasive imaging through opaque scattering layers
Bertolotti, J., van Putten, E. G., Blum, C., Lagendijk, A., Vos, W. L., & Mosk, A. P. (2012) · Nature · doi:10.1038/nature11578 · Cited by 1,183
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Self-citationSpeckle-free laser imaging using random laser illumination
Redding, B., Choma, M. A., & Cao, H. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.90 · Cited by 1,050
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Self-citationWojtkowski, M., Srinivasan, V. J., Ko, T. H., Fujimoto, J. G., Kowalczyk, A., & Duker, J. S. (2004) · Optics Express · doi:10.1364/opex.12.002404 · Cited by 1,022
Self-citationKashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Huber, R., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
Self-citationAge-related macular degeneration
Fleckenstein, M., Keenan, T. D. L., Guymer, R. H., Chakravarthy, U., Schmitz-Valckenberg, S., Klaver, C. C., Wong, W. T., & Chew, E. Y. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00265-2 · Cited by 978
Gold Nanocages: Bioconjugation and Their Potential Use as Optical Imaging Contrast Agents
Chen, J., Saeki, F., Wiley, B. J., Cang, H., Cobb, M. J., Li, Z.-Y., Au, L., Zhang, H., Kimmey, M. B., Li, X., et al. (2005) · Nano Letters · doi:10.1021/nl047950t · Cited by 977
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citationMicrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
Izatt, J. A. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090240090031 · Cited by 927
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Self-citationFrank, R. N. (2004) · New England Journal of Medicine · doi:10.1056/nejmra021678 · Cited by 891
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Self-citationde Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883
Prati, F., Regar, E., Mintz, G. S., Arbustini, E., Di Mario, C., Jang, I.-K., Akasaka, T., Costa, M., Guagliumi, G., Grube, E., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp433 · Cited by 880
Schuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Self-citationHigh-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Staurenghi, G., Sadda, S., Chakravarthy, U., & Spaide, R. F. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.02.023 · Cited by 861
Hartl, I., Li, X. D., Chudoba, C., Ghanta, R. K., Ko, T. H., Fujimoto, J. G., Ranka, J. K., & Windeler, R. S. (2001) · Optics Letters · doi:10.1364/ol.26.000608 · Cited by 852
Self-citationSpeckle in Optical Coherence Tomography
Schmitt, J. M., Xiang, S. H., & Yung, K. M. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429925 · Cited by 837
Kim, C., Favazza, C., & Wang, L. V. (2010) · Chemical Reviews · doi:10.1021/cr900266s · Cited by 807
Mittleman, D. M., Jacobsen, R. H., & Nuss, M. C. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571768 · Cited by 806
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Chiu, S. J., Li, X. T., Nicholas, P., Toth, C. A., Izatt, J. A., & Farsiu, S. (2010) · Optics Express · doi:10.1364/oe.18.019413 · Cited by 733
Jia, Y., Bailey, S. T., Wilson, D. J., Tan, O., Klein, M. L., Flaxel, C. J., Potsaid, B., Liu, J. J., Lu, C. D., Kraus, M. F., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.034 · Cited by 729
Self-citationCentral serous chorioretinopathy
Wang, M., Munch, I. C., Hasler, P. W., Prünte, C., & Larsen, M. (2008) · Acta Ophthalmologica · doi:10.1111/j.1600-0420.2007.00889.x · Cited by 726
Spaide, R. F., & Curcio, C. A. (2011) · Retina · doi:10.1097/iae.0b013e3182247535 · Cited by 723
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Quantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
Self-citationQuantification of Macrophage Content in Atherosclerotic Plaques by Optical Coherence Tomography
Tearney, G. J., Yabushita, H., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Halpern, E. F., & Bouma, B. E. (2003) · Circulation · doi:10.1161/01.cir.0000044384.41037.43 · Cited by 704
A framework for comparing structural and functional measures of glaucomatous damage
Hood, D. C., & Kardon, R. H. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.08.001 · Cited by 703
Speckle variance detection of microvasculature using swept-source optical coherence tomography
Mariampillai, A., Standish, B. A., Moriyama, E. H., Khurana, M., Munce, N. R., Leung, M. K. K., Jiang, J., Cable, A., Wilson, B. C., Vitkin, I. A., et al. (2008) · Optics Letters · doi:10.1364/ol.33.001530 · Cited by 699
Temperature-sensitive polymer-nanoshell composites for photothermally modulated drug delivery
Sershen, S. R., Westcott, S. L., Halas, N. J., & West, J. L. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<293::aid-jbm1>3.0.co;2-t · Cited by 685
Determinants of Normal Retinal Nerve Fiber Layer Thickness Measured by Stratus OCT
Budenz, D. L., Anderson, D. R., Varma, R., Schuman, J., Cantor, L., Savell, J., Greenfield, D. S., Patella, V. M., Quigley, H. A., & Tielsch, J. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.046 · Cited by 684
Self-citationKur, J., Newman, E. A., & Chan-Ling, T. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.04.004 · Cited by 678
Optical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
Self-citationReproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography
Schuman, J. S., Pedut-Kloizman, T., Hertzmark, E., Hee, M. R., Wilkins, J. R., Coker, J. G., Puliafito, C. A., Fujimoto, J. G., & Swanson, E. A. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30410-7 · Cited by 665
Self-citationDetection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography
Tan, O., Chopra, V., Lu, A. T.-H., Schuman, J. S., Ishikawa, H., Wollstein, G., Varma, R., & Huang, D. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.05.025 · Cited by 665
Self-citationDeep Learning Is Effective for Classifying Normal versus Age-Related Macular Degeneration OCT Images
Lee, C. S., Baughman, D. M., & Lee, A. Y. (2017) · Ophthalmology Retina · doi:10.1016/j.oret.2016.12.009 · Cited by 657
Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue
Horstmeyer, R., Ruan, H., & Yang, C. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.140 · Cited by 651
Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography
Wojtkowski, M., Srinivasan, V., Fujimoto, J. G., Ko, T., Schuman, J. S., Kowalczyk, A., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.023 · Cited by 640
Self-citationFong, D. S., Aiello, L. P., Ferris, F. L., & Klein, R. (2004) · Diabetes Care · doi:10.2337/diacare.27.10.2540 · Cited by 640
Topography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
Self-citationTheory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Three dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
OCT elastography: imaging microscopic deformation and strain of tissue
Schmitt, J. M. (1998) · Optics Express · doi:10.1364/oe.3.000199 · Cited by 620
Roy, A. G., Conjeti, S., Karri, S. P. K., Sheet, D., Katouzian, A., Wachinger, C., & Navab, N. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.003627 · Cited by 613
Quantifying axonal loss after optic neuritis with optical coherence tomography
Costello, F., Coupland, S., Hodge, W., Lorello, G. R., Koroluk, J., Pan, Y. I., Freedman, M. S., Zackon, D. H., & Kardon, R. H. (2006) · Annals of Neurology · doi:10.1002/ana.20851 · Cited by 610
Izatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J. (1997) · Optics Letters · doi:10.1364/ol.22.001439 · Cited by 609
Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
Schlegl, T., Waldstein, S. M., Bogunovic, H., Endstraßer, F., Sadeghipour, A., Philip, A.-M., Podkowinski, D., Gerendas, B. S., Langs, G., & Schmidt-Erfurth, U. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.10.031 · Cited by 597
Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., de Boer, J. F., Schippling, S., Vermersch, P., Kardon, R., Green, A., Calabresi, P. A., & Polman, C. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70168-x · Cited by 596
Dissecting tumour pathophysiology using intravital microscopy
Jain, R. K., Munn, L. L., & Fukumura, D. (2002) · Nature Reviews Cancer · doi:10.1038/nrc778 · Cited by 595
Makita, S., Hong, Y., Yamanari, M., Yatagai, T., & Yasuno, Y. (2006) · Optics Express · doi:10.1364/oe.14.007821 · Cited by 594
Retinal layer segmentation in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., Balcer, L. J., Calabresi, P. A., Costello, F., Frohman, T. C., Frohman, E. M., Martinez-Lapiscina, E. H., Green, A. J., Kardon, R., Outteryck, O., et al. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30278-8 · Cited by 585
Complex photonics: Dynamics and applications of delay-coupled semiconductors lasers
Soriano, M. C., García-Ojalvo, J., Mirasso, C. R., & Fischer, I. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.421 · Cited by 582
Diabetic Macular Edema: Pathogenesis and Treatment
Bhagat, N., Grigorian, R. A., Tutela, A., & Zarbin, M. A. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.001 · Cited by 571
Illuminating the metastatic process
Sahai, E. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2229 · Cited by 569
Optical coherence tomography – current and future applications
Adhi, M., & Duker, J. S. (2013) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e32835f8bf8 · Cited by 567
High-resolution full-field optical coherence tomography with a Linnik microscope
Dubois, A., Vabre, L., Boccara, A.-C., & Beaurepaire, E. (2002) · Applied Optics · doi:10.1364/ao.41.000805 · Cited by 567
Ultralow-noise mode-locked fiber lasers and frequency combs: principles, status, and applications
Kim, J., & Song, Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000465 · Cited by 567
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Self-citationTearney, G. J., Brezinski, M. E., Bouma, B. E., Hee, M. R., Southern, J. F., & Fujimoto, J. G. (1995) · Optics Letters · doi:10.1364/ol.20.002258 · Cited by 562
Self-citationZhao, Y., Chen, Z., Saxer, C., Xiang, S., de Boer, J. F., & Nelson, J. S. (2000) · Optics Letters · doi:10.1364/ol.25.000114 · Cited by 559
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Paunescu, L. A., Schuman, J. S., Price, L. L., Stark, P. C., Beaton, S., Ishikawa, H., Wollstein, G., & Fujimoto, J. G. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0514 · Cited by 536
Self-citationFercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
Spectroscopic optical coherence tomography
Morgner, U., Drexler, W., Kärtner, F. X., Li, X. D., Pitris, C., Ippen, E. P., & Fujimoto, J. G. (2000) · Optics Letters · doi:10.1364/ol.25.000111 · Cited by 516
Self-citationSex hormones and the female voice
Abitbol, J., Abitbol, P., & Abitbol, B. (1999) · Journal of Voice · doi:10.1016/s0892-1997(99)80048-4 · Cited by 510
Retinal nerve fiber layer axonal loss and visual dysfunction in optic neuritis
Trip, S. A., Schlottmann, P. G., Jones, S. J., Altmann, D. R., Garway-Heath, D. F., Thompson, A. J., Plant, G. T., & Miller, D. H. (2005) · Annals of Neurology · doi:10.1002/ana.20575 · Cited by 509
Metadata
- Authors
- Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., & Fujimoto, J. G.
- Venue
- Science
- Published
- 1991-11-22
- Volume
- 254
- Issue
- 5035
- Pages
- 1178-1181
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2418802570
- Cited by
- 13,788
- References
- 19
- FWCI
- 10.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.