The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Optical Coherence Tomography
Open accessAbstract
A technique called optical coherence tomography (OCT) has been developed for noninvasive cross-sectional imaging in biological systems. OCT uses low-coherence interferometry to produce a two-dimensional image of optical scattering from internal tissue microstructures in a way that is analogous to ultrasonic pulse-echo imaging. OCT has longitudinal and lateral spatial resolutions of a few micrometers and can detect reflected signals as small as ∼10 -10 of the incident optical power. Tomographic imaging is demonstrated in vitro in the peripapillary area of the retina and in the coronary artery, two clinically relevant examples that are representative of transparent and turbid media, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Waves and fields in optoelectronics
Haus, H. A. (1983) · Medical Entomology and Zoology · Cited by 2,153
Retinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
Lynch, D. K. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000558 · Cited by 754
Confocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Optical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Ballistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr Gate
Wang, L., Ho, P. P., Liu, C., Zhang, G., & Alfano, R. R. (1991) · Science · doi:10.1126/science.253.5021.769 · Cited by 552
Eye-length measurement by interferometry with partially coherent light
Fercher, A. F., Mengedoht, K., & Werner, W. (1988) · Optics Letters · doi:10.1364/ol.13.000186 · Cited by 516
Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain.
Chance, B., Leigh, J. S., Miyake, H., Smith, D. S., Nioka, S., Greenfeld, R., Finander, M., Kaufmann, K., Levy, W., & Young, M. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.14.4971 · Cited by 464
Weinreb, R. N. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070060105058 · Cited by 449
Cited by
Items 201–300 of 303
Grover, S., Murthy, R. K., Brar, V. S., & Chalam, K. V. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.03.006 · Cited by 312
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
A review of imaging techniques for systems biology
Kherlopian, A. R., Song, T., Duan, Q., Neimark, M. A., Po, M. J., Gohagan, J. K., & Laine, A. F. (2008) · BMC Systems Biology · doi:10.1186/1752-0509-2-74 · Cited by 310
Optical Coherence Tomography: History, Current Status, and Laboratory Work
Gabriele, M. L., Wollstein, G., Ishikawa, H., Kagemann, L., Xu, J., Folio, L. S., & Schuman, J. S. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6312 · Cited by 310
Self-citationBowd, C. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.22 · Cited by 308
Grulkowski, I., Liu, J. J., Potsaid, B., Jayaraman, V., Lu, C. D., Jiang, J., Cable, A. E., Duker, J. S., & Fujimoto, J. G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002733 · Cited by 308
Self-citationScott, C. J. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.94 · Cited by 307
Intra-arterial catheter for simultaneous microstructural and molecular imaging in vivo
Yoo, H., Kim, J. W., Shishkov, M., Namati, E., Morse, T., Shubochkin, R., McCarthy, J. R., Ntziachristos, V., Bouma, B. E., Jaffer, F. A., et al. (2011) · Nature Medicine · doi:10.1038/nm.2555 · Cited by 303
High-speed fiber–based polarization-sensitive optical coherence tomography of in vivo human skin
Saxer, C. E., de Boer, J. F., Park, B. H., Zhao, Y., Chen, Z., & Nelson, J. S. (2000) · Optics Letters · doi:10.1364/ol.25.001355 · Cited by 302
Optical coherence tomography angiography of the foveal avascular zone in diabetic retinopathy
Freiberg, F. J., Pfau, M., Wons, J., Wirth, M. A., Becker, M. D., & Michels, S. (2016) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-015-3148-2 · Cited by 299
Faber, D. J., van der Meer, F. J., Aalders, M. C. G., & van Leeuwen, T. G. (2004) · Optics Express · doi:10.1364/opex.12.004353 · Cited by 299
Cancer imaging by optical coherence tomography: preclinical progress and clinical potential
Vakoc, B. J., Fukumura, D., Jain, R. K., & Bouma, B. E. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3235 · Cited by 299
Adaptation of the central retina for high acuity vision: Cones, the fovea and the avascular zone
Provis, J. M., Dubis, A. M., Maddess, T., & Carroll, J. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.01.005 · Cited by 298
van Oostveen, W. M., & de Lange, E. C. M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22042110 · Cited by 297
Saidha, S., Syc, S. B., Durbin, M. K., Eckstein, C., Oakley, J. D., Meyer, S. A., Conger, A., Frohman, T. C., Newsome, S., Ratchford, J. N., et al. (2011) · Multiple Sclerosis Journal · doi:10.1177/1352458511418630 · Cited by 296
Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography
Götzinger, E., Pircher, M., Geitzenauer, W., Ahlers, C., Baumann, B., Michels, S., Schmidt-Erfurth, U., & Hitzenberger, C. K. (2008) · Optics Express · doi:10.1364/oe.16.016410 · Cited by 294
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293
Rahman, W., Chen, F. K., Yeoh, J., Patel, P., Tufail, A., & Da Cruz, L. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6024 · Cited by 293
Optical Coherence Tomographic Patterns of Diabetic Macular Edema
Kim, B. Y., Smith, S. D., & Kaiser, P. K. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.04.023 · Cited by 290
Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
Kim, C., Erpelding, T. N., Jankovic, L., Pashley, M. D., & Wang, L. V. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000278 · Cited by 289
Budenz, D. L., Chang, R. T., Huang, X., Knighton, R. W., & Tielsch, J. M. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1174 · Cited by 289
Polarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 288
Kedhi, E., Berta, B., Roleder, T., Hermanides, R. S., Fabris, E., IJsselmuiden, A. J. J., Kauer, F., Alfonso, F., von Birgelen, C., Escaned, J., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab433 · Cited by 288
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Recruitment of Tendon Crimp With Applied Tensile Strain
Hansen, K. A., Weiss, J. A., & Barton, J. K. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427698 · Cited by 285
Automated layer segmentation of macular OCT images using dual-scale gradient information
Yang, Q., Reisman, C. A., Wang, Z., Fukuma, Y., Hangai, M., Yoshimura, N., Tomidokoro, A., Araie, M., Raza, A. S., Hood, D. C., et al. (2010) · Optics Express · doi:10.1364/oe.18.021293 · Cited by 284
Applications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Optical coherence tomography in dermatology
Sattler, E., Kästle, R., & Welzel, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061224 · Cited by 283
Gold Nanoparticle-Mediated Photothermal Therapy: Current Status and Future Perspective
Hwang, S., Nam, J., Jung, S., Song, J., Doh, H., & Kim, S. (2014) · Nanomedicine · doi:10.2217/nnm.14.147 · Cited by 283
Adler, D. C., Ko, T. H., & Fujimoto, J. G. (2004) · Optics Letters · doi:10.1364/ol.29.002878 · Cited by 283
Self-citationHigh-resolution optical coherence tomographic imaging using a mode-locked Ti:Al_2O_3 laser source
Bouma, B., Brezinski, M. E., Fujimoto, J. G., Tearney, G. J., Boppart, S. A., & Hee, M. R. (1995) · Optics Letters · doi:10.1364/ol.20.001486 · Cited by 283
Self-citationDry Age-Related Macular Degeneration: Mechanisms, Therapeutic Targets, and Imaging
Bowes Rickman, C., Farsiu, S., Toth, C. A., & Klingeborn, M. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-12757 · Cited by 282
Surgical applications of femtosecond lasers
Chung, S. H., & Mazur, E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910053 · Cited by 281
Glaucoma: the retina and beyond
Davis, B. M., Crawley, L., Pahlitzsch, M., Javaid, F., & Cordeiro, M. F. (2016) · Acta Neuropathologica · doi:10.1007/s00401-016-1609-2 · Cited by 281
Evaluation of Age-related Macular Degeneration With Optical Coherence Tomography
Keane, P. A., Patel, P. J., Liakopoulos, S., Heussen, F. M., Sadda, S. R., & Tufail, A. (2012) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.01.006 · Cited by 280
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Manjunath, V., Goren, J., Fujimoto, J. G., & Duker, J. S. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.03.008 · Cited by 277
Self-citationSrinivasan, V. J., Monson, B. K., Wojtkowski, M., Bilonick, R. A., Gorczynska, I., Chen, R., Duker, J. S., Schuman, J. S., & Fujimoto, J. G. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0838 · Cited by 277
Self-citationHigh resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
Self-citationThree-dimensional computation of light scattering from cells
Dunn, A., & Richards-Kortum, R. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577313 · Cited by 275
Li, Y., El Habib Daho, M., Conze, P.-H., Zeghlache, R., Le Boité, H., Tadayoni, R., Cochener, B., Lamard, M., & Quellec, G. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108635 · Cited by 274
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
RETOUCH: The Retinal OCT Fluid Detection and Segmentation Benchmark and Challenge
Bogunovic, H., Venhuizen, F., Klimscha, S., Apostolopoulos, S., Bab-Hadiashar, A., Bagci, U., Beg, M. F., Bekalo, L., Chen, Q., Ciller, C., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901398 · Cited by 273
Terahertz paintmeter for noncontact monitoring of thickness and drying progress in paint film
Yasui, T., Yasuda, T., Sawanaka, K.-I., & Araki, T. (2005) · Applied Optics · doi:10.1364/ao.44.006849 · Cited by 273
Uemura, S., Ishigami, K.-I., Soeda, T., Okayama, S., Sung, J. H., Nakagawa, H., Somekawa, S., Takeda, Y., Kawata, H., Horii, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr284 · Cited by 271
Three-Dimensional Ultrahigh-Resolution Optical Coherence Tomography of Macular Diseases
Schmidt-Erfurth, U. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0370 · Cited by 271
Imaging retina to study dementia and stroke
Cheung, C. Y.-L., Ikram, M. K., Chen, C., & Wong, T. Y. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.01.001 · Cited by 271
Cheung, C. Y.-L., Ong, Y. T., Hilal, S., Ikram, M. K., Low, S., Ong, Y. L., Venketasubramanian, N., Yap, P., Seow, D., Chen, C. L. H., et al. (2015) · Journal of Alzheimer's Disease · doi:10.3233/jad-141659 · Cited by 270
Quantum-optical coherence tomography with dispersion cancellation
Abouraddy, A. F., Nasr, M. B., Saleh, B. E. A., Sergienko, A. V., & Teich, M. C. (2002) · Physical Review A · doi:10.1103/physreva.65.053817 · Cited by 270
Optical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270
MacNeill, B. D., Jang, I.-K., Bouma, B. E., Iftimia, N., Takano, M., Yabushita, H., Shishkov, M., Kauffman, C. R., Houser, S. L., Aretz, H. T., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.066 · Cited by 270
Birefringence characterization of biological tissue by use of optical coherence tomography
Everett, M. J., Schoenenberger, K., Colston, B. W., & Da Silva, L. B. (1998) · Optics Letters · doi:10.1364/ol.23.000228 · Cited by 269
Dubois, A., Levecq, O., Azimani, H., Siret, D., Barut, A., Suppa, M., del Marmol, V., Malvehy, J., Cinotti, E., Rubegni, P., et al. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.10.106007 · Cited by 269
Mueller polarimetric imaging for surgical and diagnostic applications: a review
Qi, J., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600152 · Cited by 268
Retrograde trans-synaptic retinal ganglion cell loss identified by optical coherence tomography
Jindahra, P., Petrie, A., & Plant, G. T. (2009) · Brain · doi:10.1093/brain/awp001 · Cited by 268
Kim, S. J., Equi, R., & Bressler, N. M. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.053 · Cited by 268
Sparsity based denoising of spectral domain optical coherence tomography images
Fang, L., Li, S., Nie, Q., Izatt, J. A., Toth, C. A., & Farsiu, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000927 · Cited by 268
In vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Self-citationOxygen Saturation-Dependent Absorption and Scattering of Blood
Faber, D. J., Aalders, M. C. G., Mik, E. G., Hooper, B. A., van Gemert, M. J. C., & van Leeuwen, T. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.028102 · Cited by 264
Optical coherence tomography of the retina and optic nerve – a review
Sakata, L. M., DeLeon‐Ortega, J., Sakata, V., & Girkin, C. A. (2009) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2009.02015.x · Cited by 264
de Boer, J. F., Milner, T. E., & Nelson, J. S. (1999) · Optics Letters · doi:10.1364/ol.24.000300 · Cited by 261
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Photoacoustic ophthalmoscopy for in vivo retinal imaging
Jiao, S., Jiang, M., Hu, J., Fawzi, A., Zhou, Q., Shung, K. K., Puliafito, C. A., & Zhang, H. F. (2010) · Optics Express · doi:10.1364/oe.18.003967 · Cited by 258
Self-citationRace- and Sex-Related Differences in Retinal Thickness and Foveal Pit Morphology
Wagner-Schuman, M., Dubis, A. M., Nordgren, R. N., Lei, Y., Odell, D., Chiao, H., Weh, E., Fischer, W., Sulai, Y., Dubra, A., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5886 · Cited by 258
Advances in Optical Coherence Tomography Imaging for Dermatology
Pierce, M. C., Strasswimmer, J., Hyle Park, B., Cense, B., & de Boer, J. F. (2004) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.23404.x · Cited by 257
Leber congenital amaurosis due to RPE65 mutations and its treatment with gene therapy
Cideciyan, A. V. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2010.04.002 · Cited by 256
Wakabayashi, T., Fujiwara, M., Sakaguchi, H., Kusaka, S., & Oshima, Y. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.01.017 · Cited by 256
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Neuroprotective strategies for retinal disease
Pardue, M. T., & Allen, R. S. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.02.002 · Cited by 237
Advances in the development of new biomarkers for Alzheimer’s disease
Klyucherev, T. O., Olszewski, P., Shalimova, A. A., Chubarev, V. N., Tarasov, V. V., Attwood, M. M., Syvänen, S., & Schiöth, H. B. (2022) · Translational Neurodegeneration · doi:10.1186/s40035-022-00296-z · Cited by 241
Dynamic Optical Coherence Tomography in Dermatology
Ulrich, M., Themstrup, L., de Carvalho, N., Manfredi, M., Grana, C., Ciardo, S., Kästle, R., Holmes, J., Whitehead, R., Jemec, G. B. E., et al. (2016) · Dermatology · doi:10.1159/000444706 · Cited by 230
Molecular Genetics of Human Retinal Disease
Rattner, A., Sun, H., & Nathans, J. (1999) · Annual Review of Genetics · doi:10.1146/annurev.genet.33.1.89 · Cited by 228
A feature agnostic approach for glaucoma detection in OCT volumes
Maetschke, S., Antony, B., Ishikawa, H., Wollstein, G., Schuman, J., & Garnavi, R. (2019) · PLOS ONE · doi:10.1371/journal.pone.0219126 · Cited by 213
Self-citationArtificial intelligence-based decision-making for age-related macular degeneration
Hwang, D.-K., Hsu, C.-C., Chang, K.-J., Chao, D., Sun, C.-H., Jheng, Y.-C., Yarmishyn, A. A., Wu, J.-C., Tsai, C.-Y., Wang, M.-L., et al. (2019) · Theranostics · doi:10.7150/thno.28447 · Cited by 189
Lorenz, B., Wabbels, B., Wegscheider, E., Hamel, C. P., Drexler, W., & Preising, M. N. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.01.033 · Cited by 172
Baumann, B., Baumann, S. O., Konegger, T., Pircher, M., Götzinger, E., Schlanitz, F., Schütze, C., Sattmann, H., Litschauer, M., Schmidt-Erfurth, U., et al. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001670 · Cited by 163
Applications and future directions for optical coherence tomography in dermatology*
Wan, B., Ganier, C., Du‐Harpur, X., Harun, N., Watt, F. M., Patalay, R., & Lynch, M. D. (2021) · British Journal of Dermatology · doi:10.1111/bjd.19553 · Cited by 148
Nanoparticles: A New Approach to Upgrade Cancer Diagnosis and Treatment
Yu, Z., Gao, L., Chen, K., Zhang, W., Zhang, Q., Li, Q., & Hu, K. (2021) · Nanoscale Research Letters · doi:10.1186/s11671-021-03489-z · Cited by 138
Optical coherence tomography for the characterization of basal cell carcinoma in vivo: A pilot study
Olmedo, J. M., Warschaw, K. E., Schmitt, J. M., & Swanson, D. L. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.03.013 · Cited by 120
Stieger, K., Le Meur, G., Lasne, F., Weber, M., Deschamps, J.-Y., Nivard, D., Mendes-Madeira, A., Provost, N., Martin, L., Moullier, P., et al. (2006) · Molecular Therapy · doi:10.1016/j.ymthe.2005.12.001 · Cited by 110
Hydroxychloroquine-related retinal toxicity
Ding, H. J., Denniston, A. K., Rao, V. K., & Gordon, C. (2016) · Rheumatology · doi:10.1093/rheumatology/kev357 · Cited by 100
Chang, S., & Bowden, A. K. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.9.090901 · Cited by 99
Contemporary retinal imaging techniques in diabetic retinopathy: a review
Cole, E. D., Novais, E. A., Louzada, R. N., & Waheed, N. K. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12711 · Cited by 91
Barton, J. K., Gossage, K. W., Xu, W., Ranger-Moore, J. R., Saboda, K., Brooks, C. A., Duckett, L. D., Salasche, S. J., Warneke, J. A., & Alberts, D. S. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200605 · Cited by 85
Quantum optical coherence tomography of a biological sample
Nasr, M. B., Goode, D. P., Nguyen, N., Rong, G., Yang, L., Reinhard, B. M., Saleh, B. E. A., & Teich, M. C. (2009) · Optics Communications · doi:10.1016/j.optcom.2008.11.061 · Cited by 79
Line-Field Confocal Optical Coherence Tomography (LC-OCT) for Skin Imaging in Dermatology
Latriglia, F., Ogien, J., Tavernier, C., Fischman, S., Suppa, M., Perrot, J.-L., & Dubois, A. (2023) · Life · doi:10.3390/life13122268 · Cited by 74
On-chip tunable photonic delay line
Ji, X., Yao, X., Gan, Y., Mohanty, A., Tadayon, M. A., Hendon, C. P., & Lipson, M. (2019) · APL Photonics · doi:10.1063/1.5111164 · Cited by 70
Hinderer, S., Brauchle, E., & Schenke‐Layland, K. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400762 · Cited by 68
Application of optical coherence tomography in clinical diagnosis
Wang, Y., Liu, S., Lou, S., Zhang, W., Cai, H., & Chen, X. (2019) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-190559 · Cited by 42
Multiscale observation of biological interactions of nanocarriers: From nano to macro
Jin, S., Bae, J. W., & Hong, S. (2010) · Microscopy Research and Technique · doi:10.1002/jemt.20847 · Cited by 42
Lentsch, G., Baugh, E. G., Lee, B., Aszterbaum, M., Zachary, C. B., Kelly, K. M., & Balu, M. (2022) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2022.01.016 · Cited by 41
Elsharkawy, M., Elrazzaz, M., Sharafeldeen, A., Alhalabi, M., Khalifa, F., Soliman, A., Elnakib, A., Mahmoud, A., Ghazal, M., El-Daydamony, E., et al. (2022) · Sensors · doi:10.3390/s22093490 · Cited by 38
Treatment Patterns and Health Care Costs for Age-Related Macular Degeneration in Japan
Kume, A., Ohshiro, T., Sakurada, Y., Kikushima, W., Yoneyama, S., & Kashiwagi, K. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.01.042 · Cited by 34
Retinal examination for the diagnosis of Alzheimer's disease
Kayabasi, U. (2014) · International Journal of Ophthalmic & Pathology · doi:10.4172/2324-8599.1000145 · Cited by 34
Blind dispersion compensation for optical coherence tomography
Banaszek, K., Radunsky, A. S., & Walmsley, I. A. (2007) · Optics Communications · doi:10.1016/j.optcom.2006.07.050 · Cited by 33
SoRelle, E. D., Yecies, D. W., Liba, O., Bennett, F. C., Graef, C. M., Dutta, R., Mitra, S., Joubert, L.-M., Cheshier, S., Grant, G. A., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b02656 · Cited by 24
Miniature endoscopic optical coherence tomography for calculus detection
Kao, M.-C., Lin, C.-L., Kung, C.-Y., Huang, Y.-F., & Kuo, W.-C. (2015) · Applied Optics · doi:10.1364/ao.54.007419 · Cited by 19
Self-citationGenetische und klinische Heterogenität bei LCA-Patienten: Das Ende der Einheitlichkeit
Preising, M. N., Paunescu, K., Friedburg, C., & Lorenz, B. (2007) · Der Ophthalmologe · doi:10.1007/s00347-007-1533-x · Cited by 17
Silver, R., Helms, A., Fu, W., Wang, H., Diaconu, D., Loyd, C. M., Rollins, A. M., & Ward, N. L. (2012) · Skin Research and Technology · doi:10.1111/j.1600-0846.2011.00558.x · Cited by 16
Lin, T.-Y., Chien, C., Lu, A., Paul, F., & Zimmermann, H. G. (2021) · Expert Review of Neurotherapeutics · doi:10.1080/14737175.2021.1982697 · Cited by 16
Metadata
- Authors
- Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., & Fujimoto, J. G.
- Venue
- Science
- Published
- 1991-11-22
- Volume
- 254
- Issue
- 5035
- Pages
- 1178-1181
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2418802570
- Cited by
- 13,788
- References
- 19
- FWCI
- 10.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.